A-10.9 Versa Span - Taylor Metal Kynar Color Chart - ORWA.pdf

PDF 413 KB Posted

Attached to
Residence #1300 Remodel to Include Roof - Mad River
Solicitation number
129AC720Q0065
Issued by

View the file

Other files

Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Standard Cool Kynar 500® Colors 40-Year Manufacturer’s Residential Warranty

Premium Metallic KYNAR 500® Coatings

Specialized Material in partnership with:

Standard KYNAR 500® Coatings - See chart on back for product availability

W ea th er ed Z in c

S

RI

-3

Co pp er P en ny

S

RI

-4

M et al lic

S ilv er S

RI

-5

C ha m pa gn e

S

RI

-4

A nt iq ue

P at in a

S

RI

-4

Te rr a Co tt a

S

RI

-4

Ti le

R ed

S

RI

-3

Co lo ni al

R ed

S

RI

-3

Re tr o Re d S

RI

-4

SRI=Solar Reflective Index. SRI values listed above are in accordance with ASTM E 1980 and are based on actual testing. (CRRC) Cool Roof Rating Council SRI values (CA Title 24, energy Star) are based on the grouping of colors (color families) CRRC SRI values will differ, as each color is not tested in the color family option. Coatings are low gloss 10-15% sheen. These printed chips provide a close representation of the colors. Metal samples are available upon request. Custom colors available. "Oil canning" is an inherent characteristic of roof and wall products, and not a defect, which is not a cause for panel rejection.

Ta ho e Bl ue S

RI

-2

Pa ci fic B lu e

S

RI

-2

H em lo ck

G re en S

RI

-3

Fo re st G re en

S

RI

-2

Pi ne

G re en S

RI

-2

D ar k Br on ze

S

RI

-2

Bl ac k S

RI

-2

G la ci er

W hi te S

RI

-8

Si er ra T an S

RI

-5

Pa rc hm en t

SR

I-5

St er lin g

G re y S

RI

-4

Zi nc

G re y S

RI

-4

C ha rc oa l G re y S

RI

-2

Sa dd le T an S

RI

-3

M ed iu m

B ro nz e

S

RI

-3 o z.

Co pp er oz av ai la bl e sp ec ia l o rd er

Zi nc al um e® P lu s/

G al va lu m e® S

RI

-6

Bu rg un dy

S

RI

-2

Vi nt ag e®

S

RI

-1 g

Ru st ee l™

(C ol d Ro lle d)

Ru st ee l P lu s™

(A

6)

Bo nd er iz ed

Sacramento, CA Salem, OR Seattle, WA • Phone: 503-581-8338 or 1-800-574-1388 • Fax: 503 -581-6877 • www.taylormetal.com

Co il

W id th

O R/

W A

Pa ne ls

G au ge

G la ci er

W hi te

Si er ra T an

Pa rc hm en t

St er lin g

G re y

Zi nc

G re y

Ch ar co al

G re y

Sa dd le T an

M ed iu m

B ro nz e

Ta ho e Bl ue

Pa ci fic B lu e

H em lo ck

G re en

Fo re st G re en

Pi ne

G re en

D ar k Br on ze

Bl ac k

Bu rg un dy

Te rr a Co tt a

Ti le

R ed

Co lo ni al

R ed

Re tr o Re d

M et al lic

S ilv er

Ch am pa gn e

A nt iq ue

P at in a

W ea th er ed Z in c

Co pp er P en ny

Zi nc al um e® P lu s

Bo nd er iz ed

Vi nt ag e® g

Ru st ee l™

(c ol d ro lle d) g

Ru st ee l P lu s™

(A

6) oz . C op pe r

.7

5"

12" Easy-Lock

12.75" MS150

13.75" MS100

12" CL-175

1" Smoothwall/

Soffit/ShadowLine

24 X X X X X X X X X X X X X X X X X X

26 X X X X X X X X X X X X X X X X X X

.6

16" Easy-Lock

16.625" MS150

17.625" MS100

12" Versa-Span

12" MS200

14.625" Versa-Span

14.625" MS200

12" Reveal 1-1/2" Smoothwall/

Soffit/ShadowLine

24 X X X X X X X X X X X X X X X X X X X X X X X X

22 X X X X X X X X X

A lu m in um

X X X X X X

18" Easy-Lock 18" Versa-Span

18" MS200

16" Versa-Span

16" MS200

20" MS150

16" Contour

21" MS100

12" Contour

24 X X X X X X X X X X X X X X X X X X X X X X X X X

22 X X X X X X X X X X

7/8" Corrugated

PBR

Marion "R" Panel

HR-34

24 X X X X X X X X X X X X X X X X X X X X X X X X X X X

22 X X X X X X X X X X

.0

A lu m in um

X X X X X X

" Flat Sheet

48"W x 120"L 24 X X X X X X X X X X X X X X X X X X X X X X X X X X X

22 X X X X X X X X X X

Taylor Metal Products Cool Kynar 500® All Taylor Metal Products Kynar 500® coatings utilize pigments that are specifically designed to reflect infrared light, help reduce the heat gain of a dwelling, and conform with ENERGY STAR® criteria for steep slope cool roofing products.

PVDF is a fluoropolymer that is manufactured under the trademarked name Kynar 500®. Paint finishes containing a minimum 70% PVDF resin meet the high-performance weathering criteria established by the American Architectural Manufacturing Association and are allowed to carry the Kynar 500® trademarked name.

*22 Gauge material available, please call to inquire

June 2016

Zincalume & Zincalume® Plus are registered trademarks of Bluescope Ltd. Galvalume® is a registered trademark of BIEC International, Inc.

Vintage® is a registered trademark of Steelscape, Inc.Kynar 500® is a registered trademark of Arkema, Inc. Residential: 40 year, Transferable, Non-Prorated, Limited Manufacturer's Warranty Commercial: 30 year, Non-Transferable, Non-Prorated, Limited Manufacturer's Warranty

Profile

Easy-Lock™ PBR

Versa-Span™ Marion "R" Panel™

CL-175™ HR34

MS200™ Classic 7/8" Corrugated™

MS100/MS150/Curved Contour 16" ™

Smoothwall™/Lifetime Soffit™ Contour 12" ™

ShadowLine™ Reveal™

1-1/8"

12"-16" - 18"

1-3/4"

12" - 14-5/8" - 16" - 18"

1-3/4" 1-3/8 "

12"

1-1/4"

12"

3/4" 16"

Aesthetic Roofing Vertical wall and Fascia

Structural Roofing Vertical wall and Fascia

Aesthetic Roofing Vertical wall and Fascia

Structural Roof Wall

Aesthetic Wall

Aesthetic Wall

Min Slope: 3:12 Testing: UL580 Class 90

Min Slope: 2:12 Testing: UL580 Class 90

ASTM E1592

ASTM 1646

ASTM 1680

Min Slope: 3:12

2"

12" - 14-5/8" - 16" - 18"

Structural Roofing Vertical wall and Fascia

Min Slope: .5:12 Testing: UL580 Class 90

ASTM E1592

ASTM 1646

ASTM 1680

ASTM E2140

Min Slope: 2:12 Testing: ASTM E283

ASTM E330

ASTM E331

1-1/2"

12" - 21"

Structural Roofing Vertical wall and Fascia

Min Slope: 1:12 Testing: UL580 Class 90

ASTM E1592

ASTM 1646

ASTM 1680

Testing: ASTM E283

ASTM E330

ASTM E331

Testing: ASTM E283

ASTM E330

ASTM E331

Other profiles are available.

Other profiles are available.

Structural Roof Wall

Min Slope: 2:12 Testing: ASTM E283

ASTM E330

ASTM E331

1 — 1‒1/2" 12" & 12-5/8"

Aesthetic Walls, Fascia, Soffit Available with perforation

Testing: ASTM E283

ASTM E330

ASTM E331

1 — 1‒1/2" 12" minimum

Aesthetic Walls, Fascia, Soffit Available with perforation

Testing: ASTM E283

ASTM E330

ASTM E331

36" 1-1/4"

12" Min Slope: 1:12 pitch Testing: ASTM 653, ASTM 792, UL rated when attached to a steel purlin.

Reverse Rolled Shown Standard Rolled Available

12" Color Side

1-1/4" 36"

Standard Rolled Shown Reverse rolled available

1-1/2" 6-7/8" 1-3/4" eColor Sid

32" Single Lap Roof & Wall Coverage

7/8"

2-5/8"

34" Single Lap Roof & Wall Coverage

1 1/2"

6"

Aesthetic Walls, Fascia, Soffit

Testing: ASTM E295

ASTM E330

ASTM E331

ASTM E283

6"

Available in 1" - 6" reveal

Reveal available up to 3" with 1/2" increments.

Min Slope: 1:12 pitch Testing: ASTM 653, ASTM 792, UL rated when attached to a steel purlin.

File details come from the government source that posted it. Updated .