View the file

Other files

File Type Posted
Ex. A SLAT Lease L100A (May 2025).pdf PDF
9WA2431 Request for Lease Proposal (Oct. 2024).pdf PDF
Ex. A SLAT Lease L100A (Oct. 2024).pdf PDF
9WA2431 Request for Lease Proposal (Oct. 2024).pdf PDF
Ex. B 3516A Solicitation Provisions (Simplified) (Dec. 2023).docx DOCX document
Ex 3 9WA2431 ASR Ellensburg.docx DOCX document
Ex. 4 Security Requirements (FSL Level I) (Aug. 2022).docx DOCX document
Ex. A SLAT Lease Template L100A (Oct. 2023).docx DOCX document
9WA2431 Delineated Area.pdf PDF
SLAT Request for Lease Proposals (RLP) Template R100A (Oct. 2023).docx DOCX document
Ex. D GSA From 1217 Lessor_s Annual Cost Statement (Nov. 2016).pdf PDF
Ex. E FPLS Prelease Evaluation Form 12000 (May 2015).docx DOCX document
Ex. 3 Agency Special Requirements.pdf PDF
Ex. 5 3517A General Clauses-Prelim Injunction Sep. 2022.pdf PDF
Ex. 6 9WA2431 Seismic Offer Forms A-F w instructions.pdf PDF
Ex. B 9WA2431 3516A Simplified.pdf PDF
Ex. E FAR 52.204.27 Prohibition BtyeDance Covered Application.pdf PDF
9WA2431 Sensitive Information.pdf PDF
9WA2431 SLAT RLP (Oct. 2022).pdf PDF
Ex. 4 Security Requirements (FSL Level I).pdf PDF
Ex. A 9WA2431 SLAT Lease Oct 2022.pdf PDF
Ex. 4 Security Requirements (FSL Level I) 8.29.2022.pdf PDF
9WA2431 SLAT RLP (Oct. 2022).pdf PDF
Ex C 9WA2431 FPLSEvaluationForm12000 prt A and B.pdf PDF
9WA2431 Sensitive Information Template.pdf PDF
Ex B 9WA2431 3516A_Simplified.pdf PDF
Ex. A 9WA2431 SLAT Lease (Oct. 2022).pdf PDF
Ex D FAR 52.204-24 Representation_Rev_10_2020.pdf PDF
Ex. 5 3517A General Clauses - Prelim Injunction (Sep. 2022).pdf PDF
Ex 6 9WA2431 Seismic Offer Forms A - F with instructions.pdf PDF
Ex 3 9WA2431 ASR NOAA Ellensburg 9.2.21 FINAL.pdf PDF
9WA2431 Sensitive Information Template.pdf PDF
Ex 5 3517A General Clauses Form-Prelim Injunction - (Jan. 2022).pdf PDF
Ex D FAR 52.204-24 Representation_Rev_10_2020.pdf PDF
Ex B 9WA2431 3516A_Simplified.pdf PDF
9WA2431 Request for Lease Proposal.pdf PDF
Ex 4 9WA2431 FSL I Security Requirements (Aug. 2021).pdf PDF
Ex 6 9WA2431 Seismic Offer Forms A - F with instructions.pdf PDF
Ex A 9WA2431 SLAT Lease template_L100A_10_2021.pdf PDF
Ex C 9WA2431 FPLSEvaluationForm12000 PartAandB.pdf PDF
9WA2431 Sensitive Information Template.pdf PDF
Ex B 9WA2431 3516A_Simplified.pdf PDF
Ex C 9WA2431 FPLSEvaluationForm12000_PartA-B.pdf PDF
Ex 4 9WA2431 FSL I Security Requirements _Aug. 2021.pdf PDF
Ex 5 3517A General Clauses Form-Prelim Injunction - Jan. 2022.pdf PDF
Ex 6 9WA2431 Seismic Offer Forms A - F with instructions.pdf PDF
Ex A 9WA2431 SLAT Lease template_L100A_10_2021.pdf PDF
9WA2431 Request for Lease Proposal.pdf PDF
Ex 3 9WA2431 ASR NOAA Ellensburg 9.2.21 FINAL.pdf PDF
Ex D FAR 52.204-24 Representation_Rev_10_2020.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AGENCY SPECIFIC REQUIREMENTS

PAGE 1 LESSOR: ______ GOVERNMENT: ________

9WA2431

Agency Specific Requirements

NOAA Ellensburg, WA Revised 9/26/2022

Final

GSA Public Buildings Service

NOAA Ellensburg 9WA2431

PAGE 2 LESSOR: ______ GOVERNMENT: ________

The Agency Specific Requirements (ASRs) do not reduce the minimum requirements contained within the Lease. These ASRs provides specific agency requirements, which may be complementary, more specific, or more stringent than those of the Lease minimum requirements.

SECTION 1 ROOM SCHEDULE AND DETAILS

1.01 ROOM SCHEDULE

Agency is requesting 1190 ABOA Office space to accommodate the following spaces types:

5 - Open Office Space/Work Stations – (48sq. /ft.) – 240 SQ. FT 1 - Private Offices (Supervisor, 1 Guest) – (100sq. /ft.) – 100 SQ. FT 1 - Reception Area – 100 SQ. FT (includes 1 work station 48 SQ.FT)

1 - Break Room1 – 240 SQ FT 1 - Copy Room – 80 SQ. FT.

1 - Conference Room – 380 SQ. FT 1 - Telcom Closet (IT) – 50 SQ. FT

Total –1190 SQ. FT

(A 13% circulation factor of 170 sq./ft. has been included for a total of 1345 RSF.)

1.02 SPACE DETAILS

Please refer to the Lease document for the constructions standards applicable to the interior tenant area build-out.

These standards provide a general outline of the interior build-out requirements. For a complete list of requirements refer to the Lease document.

Office and Workstations:

Each private office, individual work station and conference room shall include two voice and data lines terminated to the Telecom closet, (Isolated Ground) power outlets for computers, and regular power outlets.

Floor shall be commercial grade carpet tile

2’-0” x 2’-0” or 2’-0” x 4’-0” recessed modern, lighting fixtures

Break Area:

Sized for full size refrigerator and microwave.

Sized for table with 4 chairs

Refrigerator and microwave shall have dedicated electrical breakers

Double bowl stainless steel sink, hot and cold running water with gooseneck faucet; garbage disposal and a filtered water dispenser.

6 linear feet of high quality commercial laminate base cabinets with 6 linear feet of matching wall cabinets;

laminate counter top

Floor shall be commercial grade VCT

2’-0” x 2’-0” or 2’-0” x 4’-0” recessed modern, lighting fixtures.

Dedicated 110V 20amp duplex outlet for copy machine

Conference Room:

Shall include two voice and two data lines terminated to the Telecom closet, (Isolated Ground) power outlets for computers, and regular power outlets.

NOAA Ellensburg 9WA2431

PAGE 3 LESSOR: ______ GOVERNMENT: ________

Projector screen or supporting structure for display mount. If utilized, the display mount must be secured to supporting structure and capable of carrying ~74lbs (Mount + TV).

Lights shall be dimmable 2’-0” x 2’-0” or 2’-0” x 4’-0” recessed modern, lighting fixtures.

Security:

Electronic keyed access to exterior doors

CCTV on exterior exit

Reception Area:

Sized to accommodate a receptionist and 2 guest chairs

Parking:

2 GOV parking spaces

Telecom Closet

Telecom Closet shall be 50 SQ. FT

All Phone and Data lines shall be terminated to one or multiple wall or rack-mounted patch panels

One dedicated 20 amp outlet (NEMA 5-20), One - 2 outlet receptacle (2 plugs) with standard 120v service shall be provided.

High-Speed Internet Availability

The location must have unrestricted "high-speed" internet service available through a local or national carrier

Available "High Speed" services must be equal or greater than 25 MB Download and 10 MB Upload

Bandwidth and Usage caps must not apply to available service

Cellular or Satellite services do not qualify