This document is a comprehensive set of architectural and engineering construction documents for the Southern Utah University (SUU) Science Center Chemistry Labs Refresh project, prepared by MHTN Architects and issued by the Utah Division of Facilities Construction and Management (DFCM). The project involves a detailed renovation of existing chemistry laboratories in rooms 222, 223, and 224, with the primary objectives of resizing classrooms to accommodate 24 students, replacing outdated fume hoods, updating shelving and counter spaces, and enhancing utility and safety features. The construction cost is estimated at $950,000, and the project includes installing modern teaching equipment, ADA-compliant seating, and aesthetic upgrades such as new flooring and lighting. The documents are dated August 8, 2025, and include detailed plans for architectural, structural, mechanical, plumbing, electrical, and audio-visual systems.
The project is specifically targeted at prequalified Stage II contractors who are currently on the DFCM Prequalified Contractors list. The renovation encompasses comprehensive upgrades including laboratory furnishings, utility modifications, and systems upgrades across multiple disciplines. Key design considerations include compliance with building codes such as the 2021 International Building Code, Americans with Disabilities Act standards, and specific requirements for laboratory spaces. The documents provide extensive technical specifications, including detailed drawings for electrical, mechanical, and plumbing systems, with a focus on creating a modern, safe, and functional educational environment. The project appears to be funded through institutional capital improvement funds, with a specific emphasis on enhancing the educational infrastructure of the SUU Science Center.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ABBREVIATIONS
AC AIR CONDITIONING
AFF ABOVE FINISH FLOOR
ALT ALTERNATE
ALUM ALUMINUM
APPROX APPROXIMATE
ARCH ARCHITECTURAL
AWS ADJUSTABLE WALL SHELF
BD BOARD
BLDG BUILDING
BLKG BLOCKING
BO BOTTOM OF
BOT BOTTOM
BRB BUCKLING RESTRAINED BRACE
BRG BEARING
CB CATCH BASIN
CFMF COLD FORMED METAL FRAMING
CFOI CONTRACTOR FURNISHED OWNER INSTALLED
CIP CAST-IN-PLACE
CJ CONTROL JOINT
CL CENTER LINE
CLG CEILING
CLR CLEAR
CMU CONCRETE MASONRY UNIT
CO CLEANOUT, CLEAR OPENING
COL COLUMN
COMM COMMUNICATION
CONC CONCRETE
CONF CONFERENCE
CONST CONSTRUCT, CONSTRUCTION
CONT CONTINUOUS
COORD COORDINATE
CORR CORRIDOR
CTR CENTER
CTTD COMBINED TOILET TISSUE DISPENSER
DB DECK BEARING ELEVATION
DCS DIAPER CHANGING STATION
DEMO DEMOLITION
DF DRINKING FOUNTAIN
DIA DIAMETER
DIAG DIAGONAL
DIM DIMENSION
DN DOWN
DR DOOR
DTL DETAIL
DWG DRAWING
EIFS EXTERIOR INSULATION AND FINISH SYSTEM
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRICAL
ELEV ELEVATOR
EQ EQUAL
EQUIP EQUIPMENT
EWC ELECTRICAL WATER COOLER
EXP EXPANSION
EXT EXTERIOR
FD FLOOR DRAIN
FEC FIRE EXTINGUISHER CABINET
FIN FINISH
FIN FLR FINISH FLOOR
FLR FLOOR
FM FLOOR MOUNTED
FT FOOT, FEET
GA GAUGE, GAGE
GB GYPSUM BOARD
GI GALVANIZED IRON
GLULAM GLUED-LAMINATED TIMBER
GTB GLASS-MAT TILE BACKING BOARD
GYP BD GYPSUM BOARD
HD HAND DRYER
HRD WALL MOUNTED HAIR DRYER
HVAC HEATING, VENTILATION, AIR CONDITIONING
ID INSIDE DIAMETER
IGB IMPACT RESISTANT GYPSUM BOARD
INT INTERIOR
ISO ISOMETRIC
JAN JANITOR
JT JOINT
KD KNOCK DOWN
LAB LABORATORY
LAV LAVATORY
MAINT MAINTENANCE
MAX MAXIMUM
MECH MECHANICAL
MEZZ MEZZANINE
MFR MANUFACTURER
MH MANHOLE
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
OFOI OWNER FURNISHED OWNER INSTALLED
OFCI OWNER FURNISHED CONTRACTOR INSTALLED
OH OVERHEAD
OH DR OVERHEAD DOOR
OPP OPPOSITE
PERP PERPENDICULAR
PL PLATE, PROPERTY LINE
PLAM PLASTIC LAMINATE
PLBG PLUMBING
PLYWD PLYWOOD
PR PAIR
PREFAB PREFABRICATED
PTD PAPER TOWEL DISPENSER
PTWR PAPER TOWEL / WASTE RECEPTACLE
QTY QUANTITY
RD ROOF DRAIN
RE: REFER TO
REINF REINFORCE, REINFORCING
REQD REQUIRED
REF REFRIGERATOR
RH ROBE HOOK
RM ROOM
RO ROUGH OPENING
RTU ROOF TOP UNIT
RV ROOF VENT
SCD SEAT COVER DISPENSER
SD SOAP DISPENSER
SF SQUARE FEET
SIM SIMILAR
SNVU SANITARY NAPKIN VENDING UNIT
SNDU SANITARY NAPKIN DISPOSAL UNIT
SPEC SPECIFICATION
SQ SQUARE
STD STANDARD
STL STEEL
STRUCT STRUCTURAL
SUSP SUSPENDED
THK THICK, THICKNESS
TO TOP OF
TOB TOP OF BEAM
TOD TOP OF DECK
TOS TOP OF SLAB, TOP OF STRUCTURE
TOW TOP OF WALL
TTD TOILET TISSUE DISPENSER
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VEST VESTIBULE
VTR VENT THROUGH ROOF
W/ WITH
W/O WITHOUT
WC WATER CLOSET
WD WOOD
W WIDE FLANGE
WH WATER HEATER
WMS WALL MOUNTED SHELF
WR WASTE RECEPTICAL
WWF WELDED WIRE FABRIC
XFMR TRANSFORMER
N
GENERAL SYMBOLS
A1011
A101
S 3 1 A X 12 / 33
EL: 100'-0"
VERTICAL ELEVATION
SPOT ELEVATION
DRAWING REVISION
ROOM NAME
ROOM NUMBER
KEYED NOTES
DOOR NUMBER
SHEET WHERE DRAWN
BUILDING SECTION
WALL SECTION
DETAIL
EXTERIOR ELEVATION
WINDOW TYPE
INTERIOR WALL TYPE
REVISION NUMBER
INTERIOR ELEVATION
SEE PLUMBING, MECHANICAL AND ELECTRICAL FOR DISCIPLINE SYMBOLS
GRID REFERENCE MARK
A1 Starts at lower left corner Number Horizontal Letters Vertical
MHTN SHEET NUMBER
Sheet Number Sequencce Sheet Type Discipline
ACT1
ROOM VOLUME / AREA
CEILING TAG
SHEET WHERE DRAWN
SHEET WHERE DRAWN
SHEET WHERE DRAWN
SHEET WHERE DRAWN
A 1 01
A101
SIM
CALLOUT
SHEET WHERE DRAWN
B
A
1 2
CASEWORK TYPE
DEPTH
HEIGHT
WIDTH
LEVEL
ELEVATION
A101
SIM
A101
SIM
A101
SIM
A101
SIM
E1
EXTERIOR WALL TYPE
ROOF TYPE
FLOOR TYPE
1ST2 SIGNAGE TYPE
ROOM
150 SF
10'-0"
CEILING TYPE TAG
NORTH ARROW
PLAN NORTH
TRUE NORTH
CONCRETE EARTHGYPSUM
BOARD
RIGID/SEMI/
SAFING
INSULATION
MASONRY
BRICK
CONCRETE
MASONRY UNIT
HARDWOOD
EIFS
STONE
STEEL
GRAVEL BATT
INSULATION
MATERIALS
WOOD
FRAMING
PRECAST
BLOCKING
SPRAY FOAM
INSULATION
Room
Room
Room
PROJECT DATA
CIVIL RIGHTS
ADA Standards for Accessible Design, 2010
APPLICABLE CODES & STANDARDS
International Building Code, including Appendices C & J (IBC), 2021 ed.
International Mechanical Code (IMC), 2021 ed.
International Plumbing Code (IPC), 2021 ed.
National Electrical Code (NEC), 2023 ed.
International Energy Conservation Code (IECC), 2021 ed., Prescriptive/Performance ANSI/ASHRAE Standard 90.1-2016, Prescriptive/Trade-Off/Energy Cost Budget ICC/ANSI A117.1, 2017 ed.
International Existing Building Code (IEBC), 2021 ed., Prescriptive/Work Area/Performance International Fire Code (IFC), 2021 ed.
International Fuel Gas Code (IFGC), 2021 ed.
CRITERIA
Occupancy Classification B
Separation of Occupancies Non-separated A/B 1-hour
Construction Type IIB
Sprinkled Yes
Building Height No change
Building Area No change
Fire-Resistance Ratings for Building Elements (IBC Table 601) Construction Type: IIB Primary Structural Frame 0 Exterior Bearing Walls 0 Interior Bearing Walls 0 Exterior Non-Bearing Walls 0 Interior Non-Bearing Walls 0 Floor Construction & Associated Secondary Members 0 Roof Construction & Associates Secondary Members 0
Climate Zone: 5
Verify in Field (VIF): Field verify all dimensions and conditions at the site before submitting a bid or proceeding with any portion of the work.
Cut and Patch: Cut and patch existing building construction as required. Cutting and drilling of structural members not detailed requires the written permission of the structural engineer.
Conflicts: Whenever questions arise or conditions are encountered which are not covered by, or are in conflict with, the contract documents, consult with the Architect prior to taking any further action.
Demolish, Remove: Terms are used interchangeably to indicate detaching or tearing down items from existing construction and legally disposing of them off-site unless indicted to be removed and salvaged or removed and reinstalled.
Existing to Remain: Existing items of the building that are not to be permanently removed and that are not otherwise indicated to be demolished, removed, removed and salvaged or removed and reinstalled.
Equipment Relocation: Relocate existing mechanical and electrical as required for installation of new work.
Material Disposal: Legally dispose of all demolished or removed existing material, unless noted otherwise.
Salvage Material: Coordinate with the owner for removal of existing material noted to be returned to the owner.
Removal shall be by the owner unless noted otherwise.
Phasing: coordinate phasing of the work with the Owner and the Architect to meet the owner’s schedule.
Protection & Cleaning: Contain all construction activity within construction barricades or fences. Protect owner's existing facilities and property adjacent to new construction. During and after work of this contract is complete, clean existing areas affected by the work to the owner's satisfaction.
Protect all existing conditions that remain during phased construction and/or demolition work. Repair any damage due to new work.
Repair & Replacement: Repair or replace existing facilities or property damaged by new construction. Match existing surface finish or material.
Patch & Repair: Patch and repair existing walls, floors, ceilings, landscaping, paving or other surfaces affected by demolition to match the existing material and finish.
Core Drilling Walls and Slabs:
Use ground penetrating radar or other approved method to scan concrete over metal deck, concrete suspended slabs, masonry walls, and concrete walls to locate rebar prior to core drilling any holes. Holes shall be located to avoid rebar detected. All openings and groups of openings shall be reinforced as shown on the structural drawings.
Submit openings not shown on the structural drawings to the Structural Engineer for review prior to drilling.
PROJECT GENERAL REMODEL NOTES
SHEET NUMBER
SEAL
DESCRIPTIONDATENO.
REVISIONS
CONTRACTOR TO VERIFY DRAWINGS IN FIELD USE REFLECT LAST
REVISION DATE.
CONSULTANTS
VICINITY MAP
INDEX TO DRAWINGS -
SHEET NAME
DESCRIPTIONDATENO.
ISSUED
Confidentiality Notice:
This document is intended for use on the Project identified herein by individuals and companies involved in the design, permitting, bidding and construction of the Project. MHTN Architects, Inc. grants limited rights to distribute and reproduce this document for this express purpose only. Distribution, printing or copying this document for purposes other than those indicated is strictly prohibited. If a digital copy of this document is received in error, please delete it.
VIEW AND PRINT THIS DRAWING IN COLOR
ISSUE
MHTN PROJECT NO.
Original drawing is 30 x 42. Do not scale contents of this drawing.
MHTN Architects, Inc.
280 South 400 West Suite 250 Salt Lake City, Utah 84101 Telephone (801) 595-6700 www.mhtn.com
(SUU Main Campus)
/1
/2
:5
:2
P
M
A u to d e s k D o c s
/2
S
U U
C h e m is tr y L a b s R e fr e s h
/A
S U
U C h e m -L a b
.r v t
G001
S U
U S
C
IE
N C
E C
E N
T E
R C
H E
M
IS
T R
Y L
A B
S R
E F
R E
S H
W E
S T
S C e d a r C it y U ta h
D F
C M
DFCM
SUU SCIENCE CENTER
August 8, 2025
CHEMISTRY LABS REFRESH
370 WEST 200S
Cedar City, Utah 84720
CONSTRUCTION DOCUMENTS
CONSTRUCTION DOCUMENTS
INDEX SHEET
August 8, 2025
CONSTRUCTION DOCUMENTS
2025517
©2024 MHTN ARCHITECTS, INC.
Laboratory Design
RFD:
RESEARCH FACILITIES DESIGN
Contact:
Jorge Garcia, AIA, NCARB
Email:
jgarcia@rfd.com
Cell: 408.515.5469
Structural Design BHB Engineers
Contact:
Dallin Pedersen, SE (UT)
Email:
Dallin.Pedersen@bhbengineers.com
Cell:
801.898.0553
Mechanical Design WHW Engineering, LLC
Contact:
Caleb Lee
Email:
CalebL@whw-engineering.com
Cell:
435.467.0463
Electrical Design Spectrum Engineering
Contact:
Lance Kobayashi
Email:
Lance.Kobayashi@speceng.com
Cell:
801.928.3759
DFCM PROJECT No: 25446730
SECOND FLOOR KEY PLAN
GENERAL
G001 INDEX SHEET
G101 LIFE SAFETY PLAN
G201 MOUNTING HEIGHTS & CLEARANCES
G501 INTERIOR WALL TYPES, TYPICAL DETAILS
STRUCTURAL
S001 GENERAL STRUCTURAL NOTES
S002 SPECIAL INSPECTION NOTES
S101 SECOND FLOOR FRAMING PLAN
S501 DETAILS
ARCHITECTURAL
AD101 DEMOLITION PLANS
A101 BASEMENT & 1st FLOOR REMODEL PLANS
A102 SECOND FLOOR REMODEL PLANS
A401 INTERIOR ELEVATIONS
A601 DOOR & FINISH SCHEDULES, DETAILS
LABORATORY FURNISHINGS
LF0.01 LABORATORY FURNISHINGS GEN. NOTES, SYMBOLS & LEGENDS
LF0.02 LABORATORY FURNISHINGS SERVICE FITTINGS & SINKS SCHEDULE
LF0.03 LABORATORY FURNISHINGS CASEWORK LEGEND
LF2.00 LABORATORY FURNISHINGS FLOOR PLAN
LF3.00 LABORATORY FURNISHINGS ELEVATIONS
LF4.00 LABORATORY FURNISHINGS DETAILS
LF4.01 LABORATORY FURNISHINGS DETAILS
LF4.02 LABORATORY FURNISHINGS DETAILS
MECHANICAL
MG001 MECHANICAL GENERAL NOTES AND LEGEND
MD102 SECOND FLOOR MECHANICAL DEMOLITION PLAN
ME102 SECOND FLOOR MECHANICAL PLAN
ME102.1 SECOND FLOOR MECHANICAL REFLECTED CEILING PLAN
ME501 MECHANICAL DETAILS SCHEDULES
PG001 PLUMBING GENERAL NOTES AND LEGEND
PD102 SECOND FLOOR DOMESTIC WATER AND GAS DEMOLITION PLAN
PD102.1 SECOND FLOOR WASTE AND VENT DEMOLITION PLAN
PE102 SECOND FLOOR DOMESTIC WATER AND GAS PLAN
PE102.1 SECOND FLOOR WASTE AND VENT PLAN
PE601 PLUMBING DETAILS AND SCHEDULES
PE602 PHASE PLAN
PE701 SECOND FLOOR PLUMBING SECTIONS
PE901 SECOND FLOOR PLUMBING ISOMENTRIC
ELECTRICAL
EE001 ELECTRICAL COVER SHEET
EE002 AV ROUGH-IN SCHEDULE, GENERAL NOTES, DETAILS & DIAGRAMS
EE501 ELECTRICAL DETAILS
EE701 TYPICAL MOUNTING DETAILS
EE702 TYPICAL LABELING DETAILS
ED101 LEVEL 2 ELECTRICAL DEMOLITION FLOOR PLAN
ED201 LEVEL 1 ELECTRICAL DEMOLITION RCP
ED202 LEVEL 2 ELECTRICAL DEMOLITION RCP
EP101 LEVEL 2 POWER PLAN
EP102 ENLARGED POWER PLAN
EP601 ONE-LINE DIAGRAM
EP650 TELECOM CONDUIT RISER DIAGRAM
EL101 LEVEL 1 ELECTRICAL REFLECTED CEILING PLAN
EL102 LEVEL 2 LIGHTING PLAN
EL601 LIGHTING FIXTURE & CONTROL SCHEDULES
EY101 LEVEL 2 AUXILIARY PLAN
EY551 AUXILIARY DETAILS
EY601 FIRE ALARM RISER DIAGRAMS
EJ101 LEVEL 2 AUDIO VISUAL ROUGH-IN PLAN
TA001 SHEET INDEX, ABBREVIATIONS, AND GENERAL NOTES
TA101 LEVEL 2 AUDIO VISUAL SYSTEMS PLAN
TA501 AV SYSTEMS DETAILS
The project consists of a renovation to existing chemistry laboratories and preparation spaces within the Science Center at Southern Utah University. The main work of the remodel is specific to rooms 222, 223, and 224. This project involves resizing the classrooms to accommodate twenty-four students, replacing outdated fume hoods, updating shelving and counter spaces in the chemical prep room, and ensuring accessibility to utilities and safety features. Additionally, it emphasizes the need for appropriate storage for student materials, ADA-compliant seating, and the installation of modern teaching equipment, alongside aesthetic upgrades like new flooring and lighting.
PROJECT DISCRIPTION
• A code inspection report recommending that a certificate of occupancy be issued.
• Final report from the special inspection agency.
• Certificate of fire clearance from the State Fire Marshall.
• Report of the disinfection of the potable water system. IPC 610
• A Certificate of Compliance from the approved fabricator, if applicable.
IBC 1704.2.2
Prior to issuing a certificate of occupancy the following documents shall be submitted to the Building Official:
1 08/06/2025 Permit Review
August 8, 2025
DIVISION OF FACILITIES
CONSTRUCTION AND
MANAGEMENT
Jason Van Ausdal
08/19/2025
REVIEWED FOR CODE
COMPLIANCE
TA
E +3
6" 'C
F
HLV
LA
LG
ICW
LV
LA
LG
ICW
SK1
IHWICW J3
H
B1 8R
FH
L
C S
FH
L
W A3
0* W
A2 4R
E
+3 4"
E+34"
6'ACFH
LV LA LG IC
W
LV LA LG IC
W
FHA15LKO42FHA15R
K O
K O
6 SK3
IHWICW
EW
B2 4R
H36
FP
E+36"
E
+36"
H30*
H30*
FP
W A3
6* W
A3 6*
WA30* WA30* FPFP
R15**R15**R15**R15**R15**R15**R15**R15**R15**R15**R15** J36
S K
IH
W
IC
W
WA30*WA30* WA30* WA30* WA30* WA30*
'C
F H
LV
LA
LG
ICW
LV
LA
LG
ICW
FH
LC
S
*F
H
L S
S
E W
E +3
6"
SK1
IHWICWJ3
G
G
W A3
6* W
A3 6*
FP
G
SV
E +36"
K O
K O
0R
LV(2)
LG(2)
KO60
R *K
O
K O
0R
R *K
O
K O
0R
LV(2)LG(2) R
*K
O
K O
0R
R
E +36"
K O
K O
0R
LV(2)
LG(2)
KO60
R *K
O
K O
0R
R *K
O
K O
0R
LV(2)LG(2) R
*K
O
K O
0R
R
E +36"
R
R
K O
K O
K O
K O
0R
R *K
O
K O
0R
R
E +34"
K O
K O
KOA36AV24R*
LVLG
LVLG
LV(2)
LG(2)
LVLG
E+36"
S K
IH
W
IC
W
J36H30*H30*
S S
E W
WATER
PURIFIER
SYSTEM
6'CFH
LV LA LG IC
W
LV LA LG IC
W
FH12LCS48*FH12L
4'CFH
S K
T
C S
T C
S
E P
MT60C
E+36"
MT60C
E+36"
MT60C
E+36"
C A
R T
O F
O I
C A
R T
O F
O I
C A
R T
O F
O I
C A
R T
O F
O I
S S
E W
E +36"J3
R
W A3
6* W
A3 6*
SK1
IHWICW
'C
F
HLV
LA
LG
ICW
LV
LA
LG
ICW
FH
L C
S
FH
L
E +36"
K O
K O
0R
LV(2)LG(2)
KO60
R *K
O
K O
0R
R *K
O
K O
0R
LV(2)
LG(2) R
*K
O
K O
0R
R
E +36"
K O
K O
0R
LV(2)LG(2)
KO60
R *K
O
K O
0R
R *K
O
K O
0R
LV(2)
LG(2) R
*K
O
K O
0R
R
E +36"
R
R
K O
K O
K O
K O
0R
R *K
O
K O
0R
R
E +34"
K O
K O
KOA36AV24R*
LVLG
LV
LG
LV(2)LG(2)
LVLG
E+34"
WA24R*
KO36
S K
IH
W
IC
W
E+36"
E +36"
H36*J36
S K
IH
W
IC
W
IC
E
M A
C H
F
S
W A3
6* W
A2 4R
WA30*WA36*WA36*
E +3
6" H
J3
G S
V
FP
FP
W
A3 6*
IHWICW (IR)
CS1
CS1
CS1
CS1
C S1C S1
CS1
CS1
C S1
TO3618 TO3618 TO3618 TO3618 TO3618 TFS43*
SK1
IHWICW
FP
ICE
MACH.
FS
DRYING
OVEN
R15**R15**R15**R15**R15**R15**
E +34"
R
R
E +34"
R
R
B24R*
P W
(F U
TU
R
E
WA24R*WA30*
TO4817
TO4817
TO3617
TO3617
TO3617
TO3617
TO3617
TO3617
TO3617
TO3617
TO3617
TO3617
TO4814
TO4814
TO3614
TO3614
TO3614
TO3614
TO3614
TO3614
TO3614
TO3614
TO3614
TO3614
TO4814
TO4814
TO3614
TO3614
TO3614
TO3614
TO3614
TO3614
TO3614
TO3614
TO3614
TO3614
6'ACFH
LV LA LG IC
W
LV LA LG IC
W
FHA15LKO42FHA15R
C S1
H30*H30*KO36B12R*
WA24L*WA36*
B18R**R15**R15**R15**R15**R15**R15**R15**R15**R15**R15**
E W
R15**
DRYING
OVEN
WA30*
R
R
R
'C
F H
LV
LA
LG
ICW
LV
LA
LG
ICW
FH
LC
S
*F
H
L
CS1
CS1
R
R
R
B1 2R
E W
TP54TP54
FS
TA36
FD
FD
FD
E P
C S1
C S1
FS24R*KO24
REF/FRZ
OFOI
LEGEND - LIFE SAFETY
OCCUPANCY GROUP
OCCUPANT LOAD
OCCUPANT LOAD FACTOR
GROSS: GSF NET: NSF
SQUARE FOOTAGE
COMMON PATH OF EGRESS
TRAVEL
TRAVEL DISTANCE
DEAD END
(75 FT)
(20 FT)
(75 FT)
FIRE BARRIER - 1 HOUR
AREA USE
150 SF 7 NSF
21A-3
References to sheets below are provided to aid in navigating the drawings.
RE: G500 for Interior Wall Types which indicate ratings, reference termination details, and require rated wall identification.
RE: G300 for Fire Penetration Details
RE: G310 for UL, GA, and/or IBC reference numbers for rated assemblies
RE: A600 for the Door Schedule and door ratings.
Include one of the following two statements:
Exit Width Capacity: Exit width capacities are based on 0.3" per occupant at stairways and 0.2" per occupant at other means of egress components.
Exit Width Capacity: This project includes an automatic sprinkler system and an emergency voice/alarm communications sytem. Exit width capacities are based on 0.2" per occupant at stairways and 0.15" per occupant at other means of egress components.
LIFE SAFETY PLAN GENERAL NOTES
D E F G H J K L
761 SF
ED, CLASSROOM
20 NSF 819 SF
BUSINESS
100 NSF
795 SF
ED, CLASSROOM
20 NSF
AREA FUNCTION (IBC TABLE 1004.1.2)
BUSINESS
ED, CLASSROOM
(4
F T
2484 SF
BUSINESS
(5
F T
)(56 F T
(41 FT)
Exist. 1-Hour corridor walls
SHEET NUMBER
E
D D
C
B
A
E
C
B
A
2 3 4 5
1 2 3 4 5
MHTN PROJECT NO.
SEAL
SHEET NAME
REVISIONS
CONTRACTOR TO VERIFY DRAWINGS IN FIELD USE REFLECT
LAST REVISION DATE.
DESCRIPTIONDATE
MHTN Architects, Inc.
280 South 400 West Suite 250 Salt Lake City, Utah 84101 Telephone (801) 595-6700 www.mhtn.com
NO.
ISSUE
Confidentiality Notice:
This document is intended for use on the Project identified herein by individuals and companies involved in the design, permitting, bidding and construction of the Project. MHTN Architects, Inc. grants limited rights to distribute and reproduce this document for this express purpose only. Distribution, printing or copying this document for purposes other than those indicated is strictly prohibited. If a digital copy of this document is received in error, please delete it.
Original drawing is 30 x 42. Do not scale contents of this drawing.
/7
/2
:5
:5
A M
A u to d e s k D o c s
/2
S
U U
C h e m is tr y L a b s R e fr e s h
/A
S U
U C h e m -L a b
.r v t
LIFE SAFETY
PLAN
G101
August 8, 2025
CONSTRUCTION DOCUMENTS
2025517
S U
U S
C
IE
N C
E C
E N
T E
R C
H E
M
IS
T R
Y L
A B
S R
E F
R E
S H
W E
S T
S C e d a r C it y U ta h
D F
C M
©2024 MHTN ARCHITECTS, INC.
SCALE: 1/8" = 1'-0"
SECOND FLOOR LIFE SAFETY PLAN
KEYNOTES - LIFE SAFETY
1 Permanent Signage:"The discharge of any chemicals in the drain/sewer system is prohibited".
2 New 45-minute rated door and frame assemblies
3 New fire extinguisher
N
August 8, 2025
DIVISION OF FACILITIES
CONSTRUCTION AND
MANAGEMENT
Jason Van Ausdal
08/19/2025
M
IN
18" MIN
PULL SIDE
NOTE: DOORS IN ALCOVES, GREATER THAN 8"
DEEP TO FACE OF DOOR, SHALL COMPLY W/
CLEARANCES FOR FRONT APPROACHES.
M
IN
PUSH SIDE
LATCH ARE PROVIDED
12" MIN IF CLOSER &
(5 4"
M
IN
M
IN
(OR 42" MIN AND...)
36" MIN
PULL SIDE
Y
PUSH SIDE
NOTE: X = 12" MIN AND Y = 48" MIN IF BOTH CLOSER AND
LATCH ARE PROVIDED. X = 0" W/ NO CLOSER AND LATCH.
22" MINX
M
IN
Y
24" MIN
PULL SIDE PUSH SIDE
NOTE: Y = 48" MIN CLOSER IS PROVIDED
NOTE: Y = 54" MIN IF CLOSER IS PROVIDED.
24" MIN
M
IN
Y
SIDE APPROACH
48" MIN
M
IN
CL
FRONT APPROACH
M
IN
30" MIN
CL
M A
X
DISHWASHER DOOR, WHERE
APPLICABLE, CAN'T ENCROACH
IN CLEAR FLOOR SPACE
DW
TACKBOARD /
WHITEBOARD
FIRE
EXTINGUISHER
CABINET
ADA DOOR
OPERATOR
ADA ROOM ID FIRE
EXTINGUISHER
U N
O
WALL OR POST
MOUNTED OPERATOR
MEN
MEN
FINISH FLOOR LINE
9"
TO TACTILE LETTER
CENTERLINE
T O
S
IG
N C
L
4" M
IN
T O
B A
S E
LI
N
E O
F L
O W
E S
T T
A C
T
IL
E C
H A
R A
C T
E R
M
IN
EMERGENCY
DEFIBRILLATOR
AED
/2
B .O
. M
IR
R O
R
M A
X
T O
T H
E H
IG
H
E R
O F
R
IM
O
R C
O U
N T
E R
9" M
IN
M
IN 34
11" MIN
KNEE CLEARANCE
8" MIN
25" MAX
17" MIN
NOTE: INSULATE PIPE
WHEN EXPOSED (NO SHARP
OR ABRASIVE SURFACES
ALLOWED BELOW LAVATORY)
C
H
IL
D R
E N
'S T
O
IL
E T
R M
TOE CLEARANCE
6" MAX
M
IN
C
H
IL
D R
E N
'S T
O
IL
E T
R M
P
R E
-K T
O
IL
E T
R M
SCALE: 1/2" = 1'-0"
A3
MOUNTING HEIGHTS
SCALE: 1/2" = 1'-0"
B3
DECK MOUNTED LAV HEIGHTS
SHEET NUMBER
E
D D
C
B
A
E
C
B
A
2 3 4 5
1 2 3 4 5
MHTN PROJECT NO.
SEAL
SHEET NAME
REVISIONS
CONTRACTOR TO VERIFY DRAWINGS IN FIELD USE REFLECT
LAST REVISION DATE.
DESCRIPTIONDATE
MHTN Architects, Inc.
280 South 400 West Suite 250 Salt Lake City, Utah 84101 Telephone (801) 595-6700 www.mhtn.com
NO.
ISSUE
Confidentiality Notice:
This document is intended for use on the Project identified herein by individuals and companies involved in the design, permitting, bidding and construction of the Project. MHTN Architects, Inc. grants limited rights to distribute and reproduce this document for this express purpose only. Distribution, printing or copying this document for purposes other than those indicated is strictly prohibited. If a digital copy of this document is received in error, please delete it.
Original drawing is 30 x 42. Do not scale contents of this drawing.
/7
/2
:5
:5
A M
A u to d e s k D o c s
/2
S
U U
C h e m is tr y L a b s R e fr e s h
/A
S U
U C h e m -L a b
.r v t
MOUNTING
HEIGHTS &
CLEARANCES
G201
August 8, 2025
CONSTRUCTION DOCUMENTS
2025517
S U
U S
C
IE
N C
E C
E N
T E
R C
H E
M
IS
T R
Y L
A B
S R
E F
R E
S H
W E
S T
S C e d a r C it y U ta h
D F
C M
©2024 MHTN ARCHITECTS, INC.
SCALE: 1/2" = 1'-0"
C5
FRONT APPROACHES - SWINGING DOORS
SCALE: 1/2" = 1'-0"
D5
HINGE SIDE APPROACHES - SWINGING DOORS
SCALE: 1/2" = 1'-0"
E5
LATCH SIDE APPROACHES - SWINGING DOORS
SCALE: 1/2" = 1'-0"
B5
SINK APPROACHES AND CLEARANCE1
SCALE: 1/2" = 1'-0"
C3
LAVATORY MOUNTING HEIGHT1
August 8, 2025
DIVISION OF FACILITIES
CONSTRUCTION AND
MANAGEMENT
Jason Van Ausdal
08/19/2025
RE: G500 for wall termination details which occur at metal deck/structure or at base of wall.
Continuity:
Wall type designations imply that the walls are continuous, typically from corner to corner and until another wall type is indicated. At the intersection of walls of dissimilar sound and/or fire-resistance ratings, the wall with the more restrictive requirements shall continue through, uninterrupted and shall take precedence.
Typical Interior Wall Type: S3A, UNO.
Acoustical Sealant:
At metal stud walls with an STC rating, provide acoustical sealant at top and bottom tracks.
Sound Attenuation Batts:
Where indicated, provide sound attenuation batts sized to fit snuggly in the wall cavity. Fill all voids in the wall, from floor to deck, including at wall intersections to prevent sound leakage into adjacent rooms.
Metal Stud Partitions:
Extend interior walls and partitions from floor to roof deck or floor deck above, unless noted otherwise.
The specifications indicate a minimum metal stud gauge; increase the gauge above the minimum as required by the metal stud manufacturer for actual wall heights, deflection criteria and code required horizontal load.
Design requirements for metal stud walls: 5 PSF lateral load; L/240 deflection.
Stud Spacing: 16” on center, unless noted otherwise.
Provide bracing at 48" OC maximum at non-composite walls (walls that don't have gypsum board full height on each side of the stud).
Provide control joints at 30’-0” OC maximum. If not shown, coordinate location with Architect.
Rated Wall Identification:
Provide 3” high block letters (with 3/8” minimum stroke), stencil the fire resistance rating on the wall at 30’ maximum intervals, measured horizontally and within 15’ of the end of the wall. Provide one (1) label minimum per wall.
Locate identification in accessible concealed floor areas, if any and in the accessible space between ceiling and structure above.
Wall Schedule Abbreviations CMU - Concrete Masonry Unit GB - Gypsum Board GTB - Glass-mat Tile Backing Board IGB - Impact-resistant Gypsum Board
INTERIOR WALL TYPE GENERAL NOTES
Core Material:
S - Metal Stud M - Concrete Masonry (CMU)
Core Thickness:
Metal Studs:
Number indicates metal stud thickness, rounded down where applicable 0 - 7/8" 1 - 1 5/8" 2 - 2 1/2" 3 - 3 5/8"
Brick and CMU:
Number indicates nominal thickness 8 - 7 5/8"
Rating:
Number indicates the fire-resistive rating in hours. Unrated walls have no designation.
Height and STC:
A - Wall is continuous to the structural deck above and includes sound batt B - Wall is continuous to the structural deck above with no sound batt C - Wall extends to 6" above the ceiling and includes sound batt D - Wall extends to 6" above the ceiling with no sound batt E - Wall extends to finished ceiling and includes sound batt F - Wall extends to finished ceiling with no sound batt P - Wall is partial height {to 5'-0" AFF} {- RE: Floor Plan for top of wall}
Qualifiers:
H - CMU with honed face finish S - CMU with split face finish
Asymmetric Modifiers:
X - Single side gypsum board T - Glass-mat tile backing board with tile finish
WALL TYPE TAG DESCRIPTION
S 3 1 A X 12 / 33
QUALIFIER
HEIGHT & STC
FIRE RATING
CORE THICKNESS
CORE MATERIAL
MODIFIED STUD SPACING
MODIFIED STUD THICKNESS
METAL STUD TRACK
ACOUSTICAL SEALANT
SCHEDULED WALL
SCHEDULED BASE
METAL ROOF/FLOOR
DECK
DEFLECTION TRACK
SCHEDULED WALL
ACOUSTICAL SEALANT
1/ 2" 3/ 8"
PROVIDE SOUND BATTS IN
FLUTES AT WALLS WITH
SOUND BATTS
PROVIDE 20 GAUGE
GALVANIZED SHEET METAL
PLATE WHERE WALL RUNS
PARALLEL TO FLUTES -
SIZE: CONTINUOUS X
WIDTH REQUIRED TO
ATTACH TO DECK
METAL ROOF/FLOOR
DECK
INTUMESCENT SEALANT
FIRE SAFING
METAL
FASTENER
DEFLECTION TRACK
SCHEDULED WALL6"
1/
2"
NOTE:
SEE UL DESIGN DETAILS:
HW-D-0119 FOR SHAFT WALL
HW-D-1011 FOR METAL STUD WALL
SOUND BATTS WHERE
SCHEDULED
12 GAUGE PERIMETER
WIRE
SEISMIC CLIP
RUNNER
EDGE MOLDING
SCREW
8" MAXTYP
12 GAUGE PERIMETER
WIRE
SEISMIC CLIP
RUNNER
EDGE MOLDING
8" MAXTYP
3/4"
45°
45°.
VERTICAL
COMPRESSION STRUT
12 GA. SPLAY WIRE IN
PLANE OF EACH
COMPONENT
MAIN RUNNER
CROSS RUNNER
NOTE: PROVIDE SPLAY WIRES AND STRUT AT
12' - 0" OC EACH DIRECTION WITH
FIRST POINT OF BRACING AT 6' - 0" MAXIMUM
FROM EACH WALL
2" MAXTYP
EMT CONDUIT
1/2" 3/4" 1"
5'-10" MAX
7'-8" MAX
9'-9" MAX
1- 5/8" X 20 GA
2- 1/2" X 20 GA
(2)* 1- 5/8" X 20 GA
(2)* 2- 1/3" X 20 GA
*BACK-TO-BACK
12'-0" 13'-6" 15'-0" 15'-0"
METAL STUDS
VERTICAL COMPRESSION STRUT SCHEDULE
MAXIMUM SPAN
SYMBOL LEGEND:
SEISMIC CLIP
HANGER WIRE
PERIMETER WIRE
UNATTACHED WALL
U N
A T
T A
C H
E D
W A
LL
RE: SEISMIC BRACING DETAIL
RE: SEISMIC CLIP DETAILS
THIS SHEET FOR
ATTACHMENT TO WALLS
ATTACHED WALL
S
S
2'-0" OC
S S
S
S
S
S
S
S
S
S
SSS
S
S
S
S
S
S
S
S
A T
T A
C H
E D
W A
LL
FRAMING FOR 2X2 GRID;
2X4 GRID SIMILAR
SUSPENDED ACOUSTICAL
CEILING - SEE RCP FOR
HEIGHT AND FINISH
SCHEDULE FOR TYPE
METAL EDGE TRIM ALL
AROUND EDGES BY
CEILING SUPPLIER TO
MATCH CEILING GRID2"
ROLLER SHADE W/ FASCIA
1"
BACKER ROD & SEALANT
SHIM AS REQ'D
SCHEDULED GLAZING
GYPSUM BOARD GRID
SUSPENSION SYSTEM
WITH HANGER WIRES AT
48" OC EACH WAY
5/8" GYPSUM BOARD
SEE DEMO PLAN,
PROVIDE SMOOTH
SURFACE TO RECEIVE
PAINT
RE: STRUCTURAL
5/8" TYPE "X" GYPSUM
ONE SIDE (1 LAYER)
OTHER SIDE (2 LAYERS)
CONTINUOUS SEALANT
BATT INSULATION
GYP. BD. RETURN
@ WALL END
SCHEDULED WALL
EXISTING WALL
RE: RCP
8" EXTRUDED ALUMINUM
TRIM
SUSPENDED
ACOUSTICAL CEILING
SYSTEM
SUSPENDED
ACOUSTICAL CEILING
SYSTEM
SHEET NUMBER
E
D D
C
B
A
E
C
B
A
2 3 4 5
1 2 3 4 5
MHTN PROJECT NO.
SEAL
SHEET NAME
REVISIONS
CONTRACTOR TO VERIFY DRAWINGS IN FIELD USE REFLECT
LAST REVISION DATE.
DESCRIPTIONDATE
MHTN Architects, Inc.
280 South 400 West Suite 250 Salt Lake City, Utah 84101 Telephone (801) 595-6700 www.mhtn.com
NO.
ISSUE
Confidentiality Notice:
This document is intended for use on the Project identified herein by individuals and companies involved in the design, permitting, bidding and construction of the Project. MHTN Architects, Inc. grants limited rights to distribute and reproduce this document for this express purpose only. Distribution, printing or copying this document for purposes other than those indicated is strictly prohibited. If a digital copy of this document is received in error, please delete it.
Original drawing is 30 x 42. Do not scale contents of this drawing.
/7
/2
:5
:0
A M
A u to d e s k D o c s
/2
S
U U
C h e m is tr y L a b s R e fr e s h
/A
S U
U C h e m -L a b
.r v t
INTERIOR WALL
TYPES, TYPICAL
DETAILS
G501
August 8, 2025
CONSTRUCTION DOCUMENTS
2025517
S U
U S
C
IE
N C
E C
E N
T E
R C
H E
M
IS
T R
Y L
A B
S R
E F
R E
S H
W E
S T
S C e d a r C it y U ta h
D F
C M
©2024 MHTN ARCHITECTS, INC.
INTERIOR WALL TYPE SCHEDULE
TAG CONSTRUCTION FIRE RESISTANCE ACOUSTICAL
MARK DESCRIPTION WIDTH TERMINATION LIMITING HEIGHT HEAD DETAIL BASE DETAIL FIRE RATING STANDARD SOUND BATT STC
M81B 8" CMU 7 5/8" TO DECK 1
S3A 5/8" GB + 3 5/8" MTL STUD + 5/8" GB 4 7/8" TO DECK 16'-6" B4/G500 C4/G500 Yes 40
S3BX 5/8" GB + 3 5/8" MTL STUD 4 1/4" TO DECK 15'-6" B4/G500 C4/G500 Yes
S6A 5/8" GB + 6" MTL STUD + 5/8" GB 7 1/4" TO DECK 24'-6" B4/G500 C4/G500 Yes 41
S31A 5/8" GB + 3 5/8" MTL STUD + 5/8" GB 4 7/8" TO DECK 16'-6" B3/G500 C4/G500 1 UL U419 Yes 40
S61A 5/8" GB + 6" MTL STUD + 5/8" GB 7 1/4" TO DECK 24'-6" B3/G500 C4/G500 1 UL U419 Yes 41
SCALE: 3" = 1'-0"
B3
RATED WALL HEAD DETAIL
SCALE: 3" = 1'-0"
B4
WALL HEAD DETAIL
SCALE: 3" = 1'-0"
C4
WALL BASE DETAIL
SCALE: 1 1/2" = 1'-0"
C1
SEISMIC BRACING DETAIL
SCALE: 1 1/2" = 1'-0"
B1
CEILING DETAIL-UNATTACHED
SCALE: 3" = 1'-0"
D2
TYP GYP BD CEILING DETAIL
SCALE: 1 1/2" = 1'-0"
A1
CEILING DETAIL-ATTACHED
SCALE: 1 1/2" = 1'-0"
D1
CEILING DETAIL
SCALE: 3" = 1'-0"
E2
ACOUSTICAL CEILING CLOUD DETAIL
SCALE: 1/4" = 1'-0"
B2
TYP SUSPENDED CEILING DETAIL
SCALE: 3" = 1'-0"
D4
JAMB DETAIL
SCALE: 3" = 1'-0"
C3
FURRED WALL END DETAIL
August 8, 2025
DIVISION OF FACILITIES
CONSTRUCTION AND
MANAGEMENT
Jason Van Ausdal
08/19/2025
SHEET NUMBER
E
D D
C
B
A
E
C
B
A
2 3 4 5
1 2 3 4 5
BHB PROJECT NO.
SEAL
SHEET NAME
REVISIONS
CONTRACTOR TO VERIFY DRAWINGS IN FIELD USE REFLECT
LAST REVISION DATE.
DESCRIPTIONDATE
MHTN Architects, Inc.
280 South 400 West Suite 250 Salt Lake City, Utah 84101 Telephone (801) 595-6700 www.mhtn.com
NO.
ISSUE
Confidentiality Notice:
This document is intended for use on the Project identified herein by individuals and companies involved in the design, permitting, bidding and construction of the Project. MHTN Architects, Inc. grants limited rights to distribute and reproduce this document for this express purpose only. Distribution, printing or copying this document for purposes other than those indicated is strictly prohibited. If a digital copy of this document is received in error, please delete it.
Original drawing is 30 x 42. Do not scale contents of this drawing.
© 2024 MHTN ARCHITECTS, INC.
GENERAL
STRUCTURAL
NOTES
S001
August 8, 2025
CONSTRUCTION DOCUMENTS
250382
S U
U S
C
IE
N C
E C
E N
T E
R C
H E
M
IS
T R
Y L
A B
S R
E F
R E
S H
W E
S T
S C e d a r C it y U ta h
D F
C M
GENERAL STRUCTURAL NOTES
1 8/08/2025 PERMIT REVIEW
8/08/2025
STRUCTURALBHB
2766 South Main Street
Salt Lake City, Utah 84115 801-355-5656 bhb@bhbengineers.com
DIVISION OF FACILITIES
CONSTRUCTION AND
MANAGEMENT
Jason Van Ausdal
08/19/2025
SHEET NUMBER
E
D D
C
B
A
E
C
B
A
2 3 4 5
1 2 3 4 5
BHB PROJECT NO.
SEAL
SHEET NAME
REVISIONS
CONTRACTOR TO VERIFY DRAWINGS IN FIELD USE REFLECT
LAST REVISION DATE.
DESCRIPTIONDATE
MHTN Architects, Inc.
280 South 400 West Suite 250 Salt Lake City, Utah 84101 Telephone (801) 595-6700 www.mhtn.com
NO.
ISSUE
Confidentiality Notice:
This document is intended for use on the Project identified herein by individuals and companies involved in the design, permitting, bidding and construction of the Project. MHTN Architects, Inc. grants limited rights to distribute and reproduce this document for this express purpose only. Distribution, printing or copying this document for purposes other than those indicated is strictly prohibited. If a digital copy of this document is received in error, please delete it.
Original drawing is 30 x 42. Do not scale contents of this drawing.
© 2024 MHTN ARCHITECTS, INC.
SPECIAL
INSPECTION
NOTES
S002
CONSTRUCTION DOCUMENTS
250382
S U
U S
C
IE
N C
E C
E N
T E
R C
H E
M
IS
T R
Y L
A B
S R
E F
R E
S H
W E
S T
S C e d a r C it y U ta h
D F
C M
STRUCTURAL SHEET LIST
Sheet Number Sheet Name
S001 GENERAL STRUCTURAL NOTES
S002 SPECIAL INSPECTION NOTES
S101 SECOND FLOOR FRAMING PLAN
S501 DETAILS
REQUIREMENTS FOR SPECIAL INSPECTION, MATERIAL TESTING, AND STRUCTURAL OBSERVATION
August 8, 2025
8/08/2025
STRUCTURALBHB
2766 South Main Street
Salt Lake City, Utah 84115 801-355-5656 bhb@bhbengineers.com
DIVISION OF FACILITIES
CONSTRUCTION AND
MANAGEMENT
Jason Van Ausdal
08/19/2025
(E) 24" OWSJ AT 6'-0" O.C. +/-
D E F G H J K L 12' - 0" 28' - 0" 24' - 0" 24' - 0" 24' - 0" 12' - 0" 10' - 0"
(E) 8" MASONRY WALL, TYP
(E) 8" MASONRY WALL, TYP
(E) 8" MASONRY WALL, TYP
(E) 8" MASONRY WALL, TYP
(E) 16" WIDE MASONRY PIER
(E) 24" DEEP MASONRY LINTEL (E) 24" DEEP MASONRY LINTEL
(E) 16" WIDE MASONRY PIER
S501
S501
(E) 16" WIDE MASONRY PIER
S501
(E ) 2
8" O
W
SJ
(E ) 2
8" O
W
SJ
(E) DIAGONAL BRIDGING(E) PARALLEL BRIDGING, TYP
S501
1. VERIFY ALL FLOOR OPENINGS FOR MECHANICAL SHAFTS, STAIRS, ETC. WITH ARCHITECTURAL AND
MECHANICAL DRAWINGS.
2. WHERE PIPE PENETRATIONS, OCCUR IN (E) CONCRETE OVER METAL DECK, FOLLOW DETAIL 4/S501.
3. SEE DETAIL 8 AND 9 FOR EXISTING STEEL JOIST REINFORCING AT ANY ELEMENTS THAT ARE HEAVIER THAN
100 LBS.
FLOOR FRAMING PLAN NOTES
SEE S010 FOR LEGENDS AND SYMBOLS
SHEET NUMBER
E
D D
C
B
A
E
C
B
A
2 3 4 5
1 2 3 4 5
BHB PROJECT NO.
SEAL
SHEET NAME
REVISIONS
CONTRACTOR TO VERIFY DRAWINGS IN FIELD USE REFLECT
LAST REVISION DATE.
DESCRIPTIONDATE
MHTN Architects, Inc.
280 South 400 West Suite 250 Salt Lake City, Utah 84101 Telephone (801) 595-6700 www.mhtn.com
NO.
ISSUE
Confidentiality Notice:
This document is intended for use on the Project identified herein by individuals and companies involved in the design, permitting, bidding and construction of the Project. MHTN Architects, Inc. grants limited rights to distribute and reproduce this document for this express purpose only. Distribution, printing or copying this document for purposes other than those indicated is strictly prohibited. If a digital copy of this document is received in error, please delete it.
Original drawing is 30 x 42. Do not scale contents of this drawing.
© 2024 MHTN ARCHITECTS, INC.
SECOND FLOOR
FRAMING PLAN
S101
CONSTRUCTION DOCUMENTS
250382
S U
U S
C
IE
N C
E C
E N
T E
R C
H E
M
IS
T R
Y L
A B
S R
E F
R E
S H
W E
S T
S C e d a r C it y U ta h
D F
C M
0" 8'-0" 16'-0"4'-0"1/8" = 1'-0"
SECOND FLOOR FRAMING PLAN
1 N
O R
T H
August 8, 2025
8/08/2025
STRUCTURALBHB
2766 South Main Street
Salt Lake City, Utah 84115 801-355-5656 bhb@bhbengineers.com
DIVISION OF FACILITIES
CONSTRUCTION AND
MANAGEMENT
Jason Van Ausdal
08/19/2025
9191936-21 250382_S501-01
MASONRY INFILL DETAIL
S501
SHALL BE SOLID GROUTED.
ALL CELLS CONTAINING BARS1.
NOTES:
OF MASONRY
REQ'D TO INSTALL TOP ROW
BREAK OUT FACE SHELL AS
MASONRY INFILL
(E) MASONRY WALL
VERT REINF
#4 AT 24" O.C.
HORIZ REINF
#4 AT 24" O.C.
REINFORCING
SIZE AND SPACING OF WALL
PROVIDE DOWELS TO MATCH(E) MASONRY WALL
AT 24" O.C.
OCCURS, PROVIDE 1/2"x24" DBA
WHERE (E) EMBED PLATE
NO SCALE
8520192-21
250382_S501-02
NEW OPENING THROUGH EXISTING MASONRY WALL
S501
3" +/- 3" +/-
SAW-CUT
OPENING IN (E)
MASONRY WALL
A
A
A
1/4
TYP
1/4
SECTION A
MC8x20 STEEL CHANNEL.
ATTACH WITH 3/4"DIA AB
(5" EMBEDMENT) AT
24" O.C. - TYPICAL
(E) MASONRY WALL
L2x2x1/4 ERECTION
ANGLE - TYPICAL
(E) CONCRETE OVER
METAL DECK
SOLID GROUT OR DRY
PACK CELLS AT STEEL
CHANNEL AND AB
1/4 4-12
NOTE: CORE DRILL
CORNERS; DO NOT OVER CUT.
EXTEND UP TO WITHIN
6" OF METAL DECK
ABOVE
NO SCALE
8520192-21
250382_S501-03
NEW OPENING THROUGH EXISTING MASONRY WALL
SAW-CUT
OPENING IN (E)
MASONRY WALL
A
A
A
1/4
TYP
1/4
SECTION A
MC8x20 STEEL CHANNEL.
ATTACH WITH 3/4"DIA AB
(5" EMBEDMENT) AT
24" O.C. - TYPICAL
(E) MASONRY WALL
L2x2x1/4 ERECTION
ANGLE - TYPICAL
(E) CONCRETE OVER
METAL DECK
SOLID GROUT OR DRY
PACK CELLS AT STEEL
CHANNEL AND AB
1/4 4-12
NOTE: CORE DRILL
CORNERS; DO NOT OVER CUT.
EXTEND UP TO WITHIN
6" OF METAL DECK
ABOVE
CONNECT MASONRY
WALL TO (E) MASONRY
WALL PER 1/S501
NO SCALE
250382_S501-04
ALLOWABLE PIPE PENETRATION DETAIL
(E) CONCRETE OVER
METAL DECK
PLACE CORE DRILL AT TOP
OF DECK FLUTE AND CORE
DRILL SUCH THAT ONLY THE
TOP HORIZONTAL SECTION
OF DECK IS REMOVED
NO SCALE
528896-21 250382_S501-05
TYPICAL DECK BEARING AT INTERIOR MASONRY WALL
AT INFILL OPENING
(E) MASONRY WALL,
SEE PLAN
(E) EMBED PL
(E) CONCRETE OVER METAL
FLOOR DECK, SEE PLAN
1/2"x24" DBA WHERE EMBED
PLATE OCCURS
CHIP DOWN OR CORE
DRILL AT (E) OPENING
TO (E) EMBED PLATE
MASONRY INFILL
NO SCALE
528896-21 250382_S501-06
TYPICAL DECK BEARING AT INTERIOR MASONRY WALL
AT SAWCUT OPENING
(E) MASONRY WALL,
SEE PLAN
(E) EMBED PL
(E) CONCRETE OVER METAL
FLOOR DECK, SEE PLAN
(E) DECK BRG
CHIP DOWN (E) WALL 4" AND
GROUT WITH NON-SHRINK
GROUT. DO NOT CUT (E)
HORIZONTAL REINFORCING
OR (E) EMBED PLATES WITHOUT
APPROVAL OF ENGINEER
BEFOREHAND
NO SCALE
133176-00
250382_S501-08
TYPICAL EXISTING JOIST REINFORCING DETAIL
> 6"
> 6"
(E) STEEL JOIST, SEE PLAN
P = CONCENTRATED LOAD
ADDITIONAL DIAGONAL WEB
MEMBER. L3x3x1/4 MIN
ON EACH SIDE OF OPEN
WEB STEEL JOIST
P = CONCENTRATED LOAD
3/16
TYP
NO SCALE
8/S501, SIM
133176-01
250382_S501-09
TYPICAL HANGING MECHANICAL UNIT SUPPORT DETAIL
L2x2x3/16 FROM TOP
CHORD BEARING JOINT TO
NEAREST BOTTOM CHORD
PANEL JOINT. SEE DETAIL
ANGLE BRACE L2x2x3/16
SPACER PLATE
HANGING ROD, SEE MECH
(E) STEEL JOIST
NOTE: WHERE MECHANICAL
UNIT WEIGHS LESS THAN 300
lbs. USE 'UNISTRUT' TO
SUPPORT THE UNIT INSTEAD
OF û ë5x3x1/4.
û ë5x3x1/4 (LLV)
(E) CONCRETE OVER METAL
DECK
NO SCALE
STANDARD ADHESIVE EMBEDMENT SCHEDULE
5 5/8"
6 3/4"
4 1/2"
3 3/8"
REBAR DOWEL
(THREADED ROD SIZE)
#4 (1/2")
#3 (3/8")
#6 (3/4")
#5 (5/8")
USE "STANDARD ADHESIVE"
PER "POST INSTALLED
ANCHORS" SECTION OF THE
GENERAL STRUCTURAL
NOTES
REBAR DOWEL/THREADED
ROD, SEE DETAILS
MIN EMBEDMENT INTO CONCRETE OR
GROUTED MASONRY
MINIMUM EMBED
STANDARD ADHESIVE EMBEDMENT NOTES:
1. SPECIFIC EMBEDMENTS, NOTES AND DETAILS IN DRAWINGS SHALL GOVERN OVER THIS SCHEDULE.
2. HOLE DIAMETER SHALL BE DOWEL/ROD DIAMETER PLUS 1/8". FOLLOW MANUFACTURER'S INSTRUCTIONS FOR
HOLE PREPARATION.
3. PROVIDE A 3" MINIMUM EDGE DISTANCE TO CENTER OF HOLE.
4. CONTACT STRUCTURAL ENGINEER IF MINIMUM EMBEDMENTS INDICATED ABOVE ARE NOT ACHIEVABLE.
5. SEE "POST INSTALLED ANCHORS" SECTION OF GENERAL STRUCTURAL NOTES FOR ADDITIONAL REQUIREMENTS.
SHEET NUMBER
E
D D
C
B
A
E
C
B
A
2 3 4 5
1 2 3 4 5
BHB PROJECT NO.
SEAL
SHEET NAME
REVISIONS
CONTRACTOR TO VERIFY DRAWINGS IN FIELD USE REFLECT
LAST REVISION DATE.
DESCRIPTIONDATE
MHTN Architects, Inc.
280 South 400 West Suite 250 Salt Lake City, Utah 84101 Telephone (801) 595-6700 www.mhtn.com
NO.
ISSUE
Confidentiality Notice:
This document is intended for use on the Project identified herein by individuals and companies involved in the design, permitting, bidding and construction of the Project. MHTN Architects, Inc. grants limited rights to distribute and reproduce this document for this express purpose only. Distribution, printing or copying this document for purposes other than those indicated is strictly prohibited. If a digital copy of this document is received in error, please delete it.
Original drawing is 30 x 42. Do not scale contents of this drawing.
© 2024 MHTN ARCHITECTS, INC.
DETAILS
S501
August 8, 2025
CONSTRUCTION DOCUMENTS
250382
S U
U S
C
IE
N C
E C
E N
T E
R C
H E
M
IS
T R
Y L
A B
S R
E F
R E
S H
W E
S T
S C e d a r C it y U ta h
D F
C M
3/4" = 1'-0"7
STANDARD ADHESIVE EMBEDMENT SCHEDULE
1 8/08/2025 PERMIT REVIEW
1 1
8/08/2025
AT LINTEL ONLY:
PROVIDE MC12x31
STEEL CHANNEL WITH
PL 1/4"x7"xCONT.
S501
AT LINTEL ONLY:
PROVIDE MC12x31
STEEL CHANNEL WITH
PL 1/4"x7"xCONT.
STRUCTURALBHB
2766 South Main Street
Salt Lake City, Utah 84115 801-355-5656 bhb@bhbengineers.com
DIVISION OF FACILITIES
CONSTRUCTION AND
MANAGEMENT
Jason Van Ausdal
08/19/2025
FLOOR PLAN GENERAL NOTES
References to sheets below are provided to aid in navigating the drawings.
RE: G201 for Fixture Mounting Heights.
RE: G501 for Interior Wall Types and Typical Details
RE: A401 for Interior Wall Elevations
RE: A601 for the Door & Finish Schedules & Details
RE: LF0.01 - LF4.02 for Labratory Furnishings
Rated Construction: Provide as shown on the plans, the Life Safety Plans and elsewhere in the documents. Seal penetrations with systems applicable to the application and that have UL or other testing agency certifications.
Keynotes: Not all keynotes apply to this sheet.
Keynotes from record drawings used in backgrounds are not applicable.
D E F G H J K L
S3BX
3' -6
3 1/2"3 5/8"
G501
C1
G501
C1
G501
C1
G501
C1
G501
C1
G501
C1
ACP2 - 24" X 48"
NEW ACOUSTICAL CEILING PANEL
LIGHT FIXTURES
SEE ELECTRICAL
LEGEND - REFLECTED CEILING PLANS
MECHANICAL DIFFUSERS
SEE MECHANICAL
GB1 - NEW PAINTED GYPSUM BOARD
RL1 - DUAL MANUAL ROLLER SHADE WITH BLACK OUT
BASIS OF DESIGN:
MANF: MECHO
STYLE: SOHO ELAVATE, 3% OPEN
COLOR: SLATE
RL2 - MANUAL ROLLER SHADE
BASIS OF DESIGN:
MANF: MECHO
STYLE: SOHO ELAVATE, 3% OPEN
COLOR: SLATE
D E F G H J K L
1st Floor walls shown for coordination (gray solid lines)
1st Floor walls shown for coordination (gray solid lines)
Verify in Field (VIF): Field verify all dimensions and conditions at the site before submitting a bid or proceeding with any portion of the work.
Cut and Patch: Cut and patch existing building construction as required. Cutting and drilling of structural members not detailed requires the written permission of the structural engineer.
Conflicts: Whenever questions arise or conditions are encountered which are not covered by, or are in conflict with, the contract documents, consult with the Architect prior to taking any further action.
Demolish, Remove: Terms are used interchangeably to indicate detaching or tearing down items from existing construction and legally disposing of them off-site unless indicted to be removed and salvaged or removed and reinstalled.
Existing to Remain: Existing items of the building that are not to be permanently removed and that are not otherwise indicated to be demolished, removed, removed and salvaged or removed and reinstalled.
Equipment Relocation: Relocate existing mechanical and electrical as required for installation of new work.
Material Disposal: Legally dispose of all demolished or removed existing material, unless noted otherwise.
Salvage Material: Coordinate with the owner for removal of existing material noted to be returned to the owner.
Removal shall be by the owner unless noted otherwise.
Phasing: coordinate phasing of the work with the Owner and the Architect to meet the owner’s schedule.
Protection & Cleaning: Contain all construction activity within construction barricades or fences. Protect owner's existing facilities and property adjacent to new construction. During and after work of this contract is complete, clean existing areas affected by the work to the owner's satisfaction.
Protect all existing conditions that remain during phased construction and/or demolition work. Repair any damage due to new work.
Repair & Replacement: Repair or replace existing facilities or property damaged by new construction. Match existing surface finish or material.
Patch & Repair: Patch and repair existing walls, floors, ceilings, landscaping, paving or other surfaces affected by demolition to match the existing material and finish.
Core Drilling Walls and Slabs:
Use ground penetrating radar or other approved method to scan concrete over metal deck, concrete suspended slabs, masonry walls, and concrete walls to locate rebar prior to core drilling any holes. Holes shall be located to avoid rebar detected. All openings and groups of openings shall be reinforced as shown on the structural drawings.
Submit openings not shown on the structural drawings to the Structural Engineer for review prior to drilling.
PROJECT GENERAL REMODEL NOTES
SHEET NUMBER
E
D D
C
B
A
E
C
B
A
2 3 4 5
1 2 3 4 5
MHTN PROJECT NO.
SEAL
SHEET NAME
REVISIONS
CONTRACTOR TO VERIFY DRAWINGS IN FIELD USE REFLECT
LAST REVISION DATE.
DESCRIPTIONDATE
MHTN Architects, Inc.
280 South 400 West Suite 250 Salt Lake City, Utah 84101 Telephone (801) 595-6700 www.mhtn.com
NO.
ISSUE
Confidentiality Notice:
This document is intended for use on the Project identified herein by individuals and companies involved in the design, permitting, bidding and construction of the Project. MHTN Architects, Inc. grants limited rights to distribute and reproduce this document for this express purpose only. Distribution, printing or copying this document for purposes other than those indicated is strictly prohibited. If a digital copy of this document is received in error, please delete it.
Original drawing is 30 x 42. Do not scale contents of this drawing.
/7
/2
:5
:2
A M
A u to d e s k D o c s
/2
S
U U
C h e m is tr y L a b s R e fr e s h
/A
S U
U C h e m -L a b
.r v t
BASEMENT &
1ST FLOOR
REMODEL PLANS
A101
August 8, 2025
CONSTRUCTION DOCUMENTS
2025517
S U
U S
C
IE
N C
E C
E N
T E
R C
H E
M
IS
T R
Y L
A B
S R
E F
R E
S H
W E
S T
S C e d a r C it y U ta h
D F
C M
©2024 MHTN ARCHITECTS, INC.
SCALE: 1/8" = 1'-0"
FIRST FLOOR REFLECTED CEILING PLAN (PARTIAL PLAN)
KEYNOTES - CEILINGS
1 Existing overhead power track. Remove & reinstall to accommodate new overhead utility, see MEP drawings
3 New lay-in suspended ceiling panel system
4 New 24"x24" ceiling access panel, paint to match existing painted gyp. bd. ceiling
5 New above ceiling electrical route (power & telecom) see electrical. Core-drill walls, and carefully remove & reuse ceiling panels for access when applicable.
6 Electrical route is vertical to the new chase @ 1st Floor. Core-drill 1st Floor slab to accommodate
7 Electrical route is above ceiling and extends vertical @ 2nd Floor. Core-drill 2nd Floor slab to accommodate
8 Patch & repair gyp. bd. to accommodate utility crossing. Repaint to match existing
SCALE: 1/8" = 1'-0"
BASEMENT REFLECTED CEILING PLAN (PARTIAL PLAN)
N
N
August 8, 2025
DIVISION OF FACILITIES
CONSTRUCTION AND
MANAGEMENT
Jason Van Ausdal
08/19/2025
F E
F E
F E
FLOOR PLAN GENERAL NOTES
References to sheets below are provided to aid in navigating the drawings.
RE: G201 for Fixture Mounting Heights.
RE: G501 for Interior Wall Types and Typical Details
RE: A401 for Interior Wall Elevations
RE: A601 for the Door & Finish Schedules & Details
RE: LF0.01 - LF4.02 for Labratory Furnishings
Rated Construction: Provide as shown on the plans, the Life Safety Plans and elsewhere in the documents. Seal penetrations with systems applicable to the application and that have UL or other testing agency certifications.
Keynotes: Not all keynotes apply to this sheet.
Keynotes from record drawings used in backgrounds are not applicable.
D E F G H J K L
20'-7" 3'-4" 3'-1 3/4"
8'-4 1/8"
26'-0 5/8"
1'-9 5/8" +/-
Room
Room
Room
4A 22
224B
2A
222B
4' -7
/8
3' -0
3' -0
(Dim: face of gyp. bd )
42'-0"
(Dim: face of gyp. bd )
42'-0"
28'-0" 24'-0" 24'-0" 24'-0" 12'-0" 10'-0"
112'-0"
'-0
1'-0" Existing exterior wall assembly
Existing gyp. bd.
& furring1 5/8"
8"
5/ 8"
Existing CMU
Existing gyp. bd.
& furring
26'-0 5/8" +/-
24'-0" 24'-0" 24'-0" 24'-0"
12'-0"
2'-7 1/2"
Existing gyp. bd.
& furring
4" 8"
4' -4
8'-4 1/8"3'-4"7'-4"
8'-9" 4'-6"
S
A
S31A
S6A
S 3B
X
S 3B
XS
3B
X
S3A
3'-0"
4'-6" 8'-9"
M
B
M
B
S
A
S31A
S61A
S 3B
X
S3A
WB17 WB17
S3BX
1' -0
4' -0
2 M
B
A401
A3
A2
B2
B4A401
C3
C2
D2
D4
A401
E4
G501
C3
G501
C3
G501
C3
G501
C3
D E F G H J K L
9'-4" 9'-4" 9'-4"
8'-10"
G501
C1
G501
C1
G501
C1
G501
D2
G501
D2
G501
D2
G501
D2
E2
G501
E2
G501
D1
G501
D1
G501
D1
G501
RL2 RL1RL1RL1
ACP2 - 24" X 48"
NEW ACOUSTICAL CEILING PANEL
LIGHT FIXTURES
SEE ELECTRICAL
LEGEND - REFLECTED CEILING PLANS
MECHANICAL DIFFUSERS
SEE MECHANICAL
GB1 - NEW PAINTED GYPSUM BOARD
RL1 - DUAL MANUAL ROLLER SHADE WITH BLACK OUT
BASIS OF DESIGN:
MANF: MECHO
STYLE: SOHO ELAVATE, 3% OPEN
COLOR: SLATE
RL2 - MANUAL ROLLER SHADE
BASIS OF DESIGN:
MANF: MECHO
STYLE: SOHO ELAVATE, 3% OPEN
COLOR: SLATE
Verify in Field (VIF): Field verify all dimensions and conditions at the site before submitting a bid or proceeding with any portion of the work.
Cut and Patch: Cut and patch existing building construction as required. Cutting and drilling of structural members not detailed requires the written permission of the structural engineer.
Conflicts: Whenever questions arise or conditions are encountered which are not covered by, or are in conflict with, the contract documents, consult with the Architect prior to taking any further action.
Demolish, Remove: Terms are used interchangeably to indicate detaching or tearing down items from existing construction and legally disposing of them off-site unless indicted to be removed and salvaged or removed and reinstalled.
Existing to Remain: Existing items of the building that are not to be permanently removed and that are not otherwise indicated to be demolished, removed, removed and salvaged or removed and reinstalled.
Equipment Relocation: Relocate existing mechanical and electrical as required for installation of new work.
Material Disposal: Legally dispose of all demolished or removed existing material, unless noted otherwise.
Salvage Material: Coordinate with the owner for removal of existing material noted to be returned to the owner.
Removal shall be by the owner unless noted otherwise.
Phasing: coordinate phasing of the work with the Owner and the Architect to meet the owner’s schedule.
Protection & Cleaning: Contain all construction activity within construction barricades or fences. Protect owner's existing facilities and property adjacent to new construction. During and after work of this contract is complete, clean existing areas affected by the work to the owner's satisfaction.
Protect all existing conditions that remain during phased construction and/or demolition work. Repair any damage due to new work.
Repair & Replacement: Repair or replace existing facilities or property damaged by new construction. Match existing surface finish or material.
Patch & Repair: Patch and repair existing walls, floors, ceilings, landscaping, paving or other surfaces affected by demolition to match the existing material and finish.
Core Drilling Walls and Slabs:
Use ground penetrating radar or other approved method to scan concrete over metal deck, concrete suspended slabs, masonry walls, and concrete walls to locate rebar prior to core drilling any holes. Holes shall be located to avoid rebar detected. All openings and groups of openings shall be reinforced as shown on the structural drawings.
Submit openings not shown on the structural drawings to the Structural Engineer for review prior to drilling.
PROJECT GENERAL REMODEL NOTES
SHEET NUMBER
E
D D
C
B
A
E
C
B
A
2 3 4 5
1 2 3 4 5
MHTN PROJECT NO.
SEAL
SHEET NAME
REVISIONS
CONTRACTOR TO VERIFY DRAWINGS IN FIELD USE REFLECT
LAST REVISION DATE.
DESCRIPTIONDATE
MHTN Architects, Inc.
280 South 400 West Suite 250 Salt Lake City, Utah 84101 Telephone (801) 595-6700 www.mhtn.com
NO.
ISSUE
Confidentiality Notice:
This document is intended for use on the Project identified herein by individuals and companies involved in the design, permitting, bidding and construction of the Project. MHTN Architects, Inc. grants limited rights to distribute and reproduce this document for this express purpose only. Distribution, printing or copying this document for purposes other than those indicated is strictly prohibited. If a digital copy of this document is received in error, please delete it.
Original drawing is 30 x 42. Do not scale contents of this drawing.
/7
/2
:5
:2
A M
A u to d e s k D o c s
/2
S
U U
C h e m is tr y L a b s R e fr e s h
/A
S U
U C h e m -L a b
.r v t
SECOND FLOOR
REMODEL PLANS
A102
August 8, 2025
CONSTRUCTION DOCUMENTS
2025517
S U
U S
C
IE
N C
E C
E N
T E
R C
H E
M
IS
T R
Y L
A B
S R
E F
R E
S H
W E
S T
S C e d a r C it y U ta h
D F
C M
©2024 MHTN ARCHITECTS, INC.
SCALE: 1/8" = 1'-0"
SECOND FLOOR PARTIAL PLAN
N
SCALE: 1/8" = 1'-0"
SECOND FLOOR PARTIAL REFLECTED CEILING PLAN
N
KEYNOTES - FLOOR PLANS
1 New door & frame within existing gyp. bd. wall assembly; patch, repair & repaint gyp.
bd. to accommodate (both sides of wall)
2 New door & frame within existing CMU wall assembly; patch, repair & repaint to accommodate (both sides of wall)
3 New floor drain, core-drill slab to accommodate, see plumbing dwgs.
4 Provide sign at/near splash: "As directed by the Cedar City Pretreatment Coordinator, the discharge of any chemicals in drain/sewer system is prohibited.
5 CFCI 5lb ABC surface mounted fire extinguisher
6 Install owner supplied emergency kit signage to the face of the cabinet
KEYNOTES - CEILINGS
1 Existing overhead power track. Remove & reinstall to accommodate new overhead utility, see MEP drawings
3 New lay-in suspended ceiling panel system
4 New 24"x24" ceiling access panel, paint to match existing painted gyp. bd. ceiling
5 New above ceiling electrical route (power & telecom) see electrical. Core-drill walls, and carefully remove & reuse ceiling panels for access when applicable.
6…