This document is a Questions and Answers (Q&A) exhibit for Solicitation 89503625QSW000182, providing detailed information about a Liquid Oxygen (LOX) contract for the Southeastern Power Administration (SWPA). The Q&A reveals that the annual LOX requirement ranges from 545 to 654 Tons, with deliveries typically occurring between July 1st and December 31st. Standard delivery sizes are 4,250 to 8,500 gallons (20 to 40 Tons), with a frequency of 1-3 times per week, contingent on lake reservoir dissolved oxygen levels and energy demands. The facility has two 11,000-gallon storage tanks, and the LOX procurement is primarily influenced by lake reservoir dissolved oxygen levels, wholesale electric energy demands, and replacement costs. The document also clarifies that the tanks do not have telemetry units accessible to the contractor.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Exhibit C

Solicitation 89503625QSW000182

Questions and Answers

1. Question: Would it be possible for you to provide some general information based on previous orders? Specifically, we are trying to understand the typical annual requirement for Liquid Oxygen.

a. Answer: The typical annual requirement is for deliveries between July 1st and December 31st, with annual volumes for 2023 were 545 Tons and for 2024 were 654 Tons. ranging from approximately 100,000 to 200,000 standard cubic feet (ScF).

2. Question: What is the standard delivery size per order in gallons?

a. Answer: Standard delivery sizes typically range from 4,250 to 8,500 gallons

(equivalent to 20 to 40 Tons). Delivery frequency is usually 1 to 3 times per week, depending on lake reservoir dissolved oxygen levels and usage patterns.

**Note: SWPA’s annual requirement is based primarily on three factors: Lake reservoir dissolved oxygen levels, wholesale electric energy demands, and wholesale electric energy replacement costs.

3. Question: Do these tanks have telemetry units installed and are they accessible for the contractor?

a. Answer: No, they do not.

4. Question: Can you confirm the size of the tanks in gallons? 9000G?

a. Answer: Two (2) tanks. 11,000 gallons each.