Table 1 ATTACHMENT B - RFQ 89503221QWA000352 - Schedule of Supplies/Services and Prices/Costs *ANY TEST NOT AVAILABLE FOR EXPEDITED AND/OR SAME DAY TESTING SHALL BE NOTED BY THE OFFEROR All quanities are estimates only and not a guarantee IF ESTIMATED QUANTITY IS ZERO, PROVIDE PRICING IN THE EVENT TEST BECOMES NEEDED IN THE FUTURE
| CLIN | Test name/Description | Est Qty | ||
| (Routine) | UOM | Unit Price | Est Qty | |
| (Expedited) | UOM | Unit Price | Est Qty | |
| (Same Day) | UOM | Unit Price | Total | |
| BASE YEAR | ||||
| 00001 | Transformer Dissolved Gas Analysis - ASTM D‐3612 |
Consisting of following components:
| Hydrogen (H2) ‐ ppm, Methane (CH4) ‐ ppm, Ethane (C2H6) ‐ ppm, Ethylene (C2H4) ‐ ppm, Acetylene (C2H2) ‐ ppm, Carbon Monoxide (CO) ‐ ppm, Carbon Dioxide (C02) ‐ ppm, Nitrogen (N2) ‐ ppm, Oxygen (O2) ‐ ppm, Total Gas ‐ ppm, Total Combustable Gas ‐ ppm, and Equivalent TCG ‐ % | 600 | EA | 15 | EA | 10 | EA | $ - 0 | |
| 00002 | Transformer Physical‐Chemical |
Consisting of following components:
| Moisture in oil ‐ ppm - ASTM D‐1533 B, IFT ‐ dynes/cm - ASTM D‐971, Acid # ‐ mg KOH/g - ASTM D‐974, Color # ‐ relative - ASTM D‐1524, Visual ‐ string - ASTM D‐1524, Dielectric (a) ‐ kV MM‐C - ASTM D‐877, Dielectric (b) ‐kV MM‐C - ASTM D‐1816, Viscosity ‐ SFS (NUMERIC) - ASTM D‐88, Specific Gravity ‐ relative - ASTM D‐1298, Power Factor @ 25 C ‐ % - ASTM D‐924, Power Factor @ 100 C ‐ % - ASTM D‐924, and Flash Point‐Pour Point ‐ C/F - ASTM D‐92 | 175 | EA | 5 | EA | 5 | EA | $ - 0 | |
| 00003 | Transformer Metals in Oil - ASTM D‐3635 |
Consisting of following components:
Silver (Ag) ‐ ppm, Chromium (Cr) ‐ ppm, Copper (Cu) ‐ ppm, Molybdenium (Mo) ‐ ppm,
| Nickel (Ni) ‐ ppm, Lead (Pb) ‐ ppm, Tin (Sn) ‐ ppm, and Tungsten (W) ‐ ppm | 10 | EA | 0 | EA | 0 | EA | $ - 0 | |
| 00004 | Transformer Fault/Wear Metals in Oil - ASTM D‐7151 |
Consisting of following components:
| Silver (Ag) ‐ ppm, Aluminum (Al) ‐ ppm, Copper (Cu) ‐ ppm, Iron (Fe) ‐ ppm, Silicon (Si) ‐ ppm, Tin (Sn) ‐ ppm, and Zinc (Zn) ‐ ppm | 0 | EA | 0 | EA | 0 | EA | $ - 0 | |
| 00005 | Transformer Pump Wear Metals in Oil - ASTM D‐7151 |
Consisting of following components:
| Silver (Ag) ‐ ppm, Aluminum (Al) ‐ ppm, Barium (Ba) ‐ ppm, Cromium (Cr) ‐ ppm, Copper (Cu) ‐ ppm, Iron (Fe) ‐ ppm, Magnesium (Mg) ‐ ppm, Molybdenum (Mo) ‐ ppm, Nickel (Ni) ‐ ppm, P ‐ ppm, Lead (Pb) ‐ ppm, Silicon (Si) ‐ ppm, Tin (Sn) ‐ ppm, Vandium (V) ‐ ppm, Zinc (Zn) ‐ ppm | 0 | EA | 0 | EA | 0 | EA | $ - 0 | |||||
| 00006 | LOAD TAP CHANGER Consisting of the following components: Transformer Dissolved Gas Analysis ASTM D-3615, Moisture in oil ‐ ppm - ASTM D‐1533 B, IFT ‐ dynes/cm - ASTM D‐971, Acid # ‐ mg KOH/g - ASTM D‐974, Color # ‐ relative - ASTM D‐1524, Visual ‐ string - ASTM D‐1524, Dielectric (a) ‐ kV MM‐C - ASTM D‐877, Dielectric (b) ‐kV MM‐C - ASTM D‐1816, 2,6-di-tert-butyl-Butyl-Phenol/p-Cresol - D-2668; Viscosity ‐ SFS (NUMERIC) - ASTM D-445, Specific Gravity ‐ relative - ASTM D‐1298, Power Factor @ 25 C ‐ % - ASTM D‐924, Power Factor @ 100 C ‐ % - ASTM D‐924, and Flash Point‐Pour Point ‐ C/F - ASTM D‐92, Corrosive Silver - D-1275 (AS NEEDED), Degree of Polmerization - D-4243, PCB (AS NEEDED) Metals in oil - ASTM D-7151, Fault/Wear metals in Oil - ASTM D-7151, Particle - ASTM D-6786, Furanic Compounds- ASTM D-5837 | 45 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| 00007 | Circuit Breaker Oil Analysis (BOA) |
Consisting of following components:
| Dissolved Gas Analysis - ASTM D‐3612, Moisture Content ‐ ppm - ASTM D‐1533b, Power Factor ‐ % @ 25 Centigrade - ASTM D‐924, Power Factor ‐ % @ 100 Centigrade - ASTM D‐924, Particle Characterization Laser Scan/ISO Code ‐ count - ASTM D‐6786, Metals In Oil, 8 Metal Scan, ppm - ASTM D‐3635, Visual string - ASTM D‐1524, Specific Gravity SG ralative - ASTM D‐1298, and Partical Count in Oil: > 4 µm ‐ count, > 6 µm ‐ count, > 10 µm ‐ count, > 14 µm ‐ count, and > 21 µm ‐ count | 7 | EA | 0 | EA | 0 | EA | $ - 0 | |||||
| 00008 | Oxidation Inhibitor ‐ % - ASTM D‐2668 | 52 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| 00009 | Furan Screen ‐ ppb (When a Furan test is requested, test results must be broken down and list each compound found in the sample (5H2F, 2FOL, 2FAL, 2ACF and 5M2F) and expressed in PPB.) | 180 | EA | 15 | EA | 0 | EA | $ - 0 | ||||
| 00010 | Corrosive Sulphur ‐ ppm - ASTM D‐1275, 3 day test | 1 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| 00011 | *Degree of Polymarization ‐ DP - ASTM D‐4243 | 0 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| 00012 | PCB ‐ ppm - EPA 600 / 4‐81‐045 | 25 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| 00013 | Color ‐ Relative - ASTM D‐1524 | 0 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| 00014 | Dielectric ‐ kV MM‐C - ASTM D‐877 | 0 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| 00015 | Dielectric ‐ kV MM‐C - ASTM D‐1816 | 0 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| 00016 | Acidity (modified) ‐ mg KOH/g - ASTM D‐974 | 0 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| 00017 | Interfacial Tension ‐ dyne/cm - ASTM D‐971 | 0 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| 00018 | Metals in Oil, 8 Metal Scan ‐ ppm - ASTM D‐3635 | 0 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| 00019 | Water in Oil - ASTM D1533 | 10 | EA | 6 | EA | 0 | EA | $ - 0 | ||||
| 00020 | Multi part screen/test (69kV and higher) one test that screens for the following: Color/Visual (ASTM D1500/D1524); Water/RS (ASTMD1533); Dielectric (ASTM D1816); Interfacial Tension (ASTM D971); Power Factor 25Deg C (ASTM D924); Power Factor 100 Deg C (ASTM D924); Specific Gravity (ASTM D1298); Neut. No (ASTM D974) | 410 | EA | 20 | EA | 0 | EA | $ - 0 | ||||
| 00021 | Multi part screen/test (69kV and lower) one test that screens for the following: Color/Visual (ASTM D1500/D1524); Water/RS (ASTMD1533); Dielectric (ASTM D1816); Interfacial Tension (ASTM D971); Power Factor 25Deg C (ASTM D924); Power Factor 100 Deg C (ASTM D924); Specific Gravity (ASTM D1298); Neut. No (ASTM D974) | 50 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| 00022 | Viscosity - ASTM D445 | 0 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| 00023 | Oxidation inhibitor in Natural Esters (FR3 Insulating Fluid) - ASTM D‐4768 | 0 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| BASE YEAR TOTAL | $ - 0 | |||||||||||
| OPTION YEAR ONE | ||||||||||||
| CLIN | Test name/Description | Est Qty | ||||||||||
| (Routine) | UOM | Unit Price | Est Qty | |||||||||
| (Expedited) | UOM | Unit Price | Est Qty | |||||||||
| (Same Day) | UOM | Unit Price | Total | |||||||||
| 10001 | Transformer Dissolved Gas Analysis - ASTM D‐3612 |
Consisting of following components:
| Hydrogen (H2) ‐ ppm, Methane (CH4) ‐ ppm, Ethane (C2H6) ‐ ppm, Ethylene (C2H4) ‐ ppm, Acetylene (C2H2) ‐ ppm, Carbon Monoxide (CO) ‐ ppm, Carbon Dioxide (C02) ‐ ppm, Nitrogen (N2) ‐ ppm, Oxygen (O2) ‐ ppm, Total Gas ‐ ppm, Total Combustable Gas ‐ ppm, and Equivalent TCG ‐ % | 600 | EA | 15 | EA | 10 | EA | $ - 0 | |
| 10002 | Transformer Physical‐Chemical |
Consisting of following components:
| Moisture in oil ‐ ppm - ASTM D‐1533 B, IFT ‐ dynes/cm - ASTM D‐971, Acid # ‐ mg KOH/g - ASTM D‐974, Color # ‐ relative - ASTM D‐1524, Visual ‐ string - ASTM D‐1524, Dielectric (a) ‐ kV MM‐C - ASTM D‐877, Dielectric (b) ‐kV MM‐C - ASTM D‐1816, Viscosity ‐ SFS (NUMERIC) - ASTM D445 ASTM D‐88, Specific Gravity ‐ relative - ASTM D‐1298, Power Factor @ 25 C ‐ % - ASTM D‐924, Power Factor @ 100 C ‐ % - ASTM D‐924, and Flash Point‐Pour Point ‐ C/F - ASTM D‐92 | 175 | EA | 5 | EA | 5 | EA | $ - 0 | |
| 10003 | Transformer Metals in Oil - ASTM D‐3635 |
Consisting of following components:
Silver (Ag) ‐ ppm, Chromium (Cr) ‐ ppm, Copper (Cu) ‐ ppm, Molybdenium (Mo) ‐ ppm,
| Nickel (Ni) ‐ ppm, Lead (Pb) ‐ ppm, Tin (Sn) ‐ ppm, and Tungsten (W) ‐ ppm | 10 | EA | 0 | EA | 0 | EA | $ - 0 | |
| 10004 | Transformer Fault/Wear Metals in Oil - ASTM D‐7151 |
Consisting of following components:
| Silver (Ag) ‐ ppm, Aluminum (Al) ‐ ppm, Copper (Cu) ‐ ppm, Iron (Fe) ‐ ppm, Silicon (Si) ‐ ppm, Tin (Sn) ‐ ppm, and Zinc (Zn) ‐ ppm | 0 | EA | 0 | EA | 0 | EA | $ - 0 | |
| 10005 | Transformer Pump Wear Metals in Oil - ASTM D‐7151 |
Consisting of following components:
| Silver (Ag) ‐ ppm, Aluminum (Al) ‐ ppm, Barium (Ba) ‐ ppm, Cromium (Cr) ‐ ppm, Copper (Cu) ‐ ppm, Iron (Fe) ‐ ppm, Magnesium (Mg) ‐ ppm, Molybdenum (Mo) ‐ ppm, Nickel (Ni) ‐ ppm, P ‐ ppm, Lead (Pb) ‐ ppm, Silicon (Si) ‐ ppm, Tin (Sn) ‐ ppm, Vandium (V) ‐ ppm, Zinc (Zn) ‐ ppm | 0 | EA | 0 | EA | 0 | EA | $ - 0 | |||||
| 10006 | LOAD TAP CHANGER Consisting of the following components: Transformer Dissolved Gas Analysis ASTM D-3615, Moisture in oil ‐ ppm - ASTM D‐1533 B, IFT ‐ dynes/cm - ASTM D‐971, Acid # ‐ mg KOH/g - ASTM D‐974, Color # ‐ relative - ASTM D‐1524, Visual ‐ string - ASTM D‐1524, Dielectric (a) ‐ kV MM‐C - ASTM D‐877, Dielectric (b) ‐kV MM‐C - ASTM D‐1816, 2,6-di-tert-butyl-Butyl-Phenol/p-Cresol - D-2668; Viscosity ‐ SFS (NUMERIC) - ASTM D-445, Specific Gravity ‐ relative - ASTM D‐1298, Power Factor @ 25 C ‐ % - ASTM D‐924, Power Factor @ 100 C ‐ % - ASTM D‐924, and Flash Point‐Pour Point ‐ C/F - ASTM D‐92, Corrosive Silver - D-1275 (AS NEEDED), Degree of Polmerization - D-4243, PCB (AS NEEDED) Metals in oil - ASTM D-7151, Fault/Wear metals in Oil - ASTM D-7151, Particle - ASTM D-6786, Furanic Compounds- ASTM D-5837 | 45 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| 10007 | Circuit Breaker Oil Analysis (BOA) |
Consisting of following components:
| Dissolved Gas Analysis - ASTM D‐3612, Moisture Content ‐ ppm - ASTM D‐1533b, Power Factor ‐ % @ 25 Centigrade - ASTM D‐924, Power Factor ‐ % @ 100 Centigrade - ASTM D‐924, Particle Characterization Laser Scan/ISO Code ‐ count - ASTM D‐6786, Metals In Oil, 8 Metal Scan, ppm - ASTM D‐3635, Visual string - ASTM D‐1524, Specific Gravity SG ralative - ASTM D‐1298, and Partical Count in Oil: > 4 µm ‐ count, > 6 µm ‐ count, > 10 µm ‐ count, > 14 µm ‐ count, and > 21 µm ‐ count | 7 | EA | 0 | EA | 0 | EA | $ - 0 | |||||
| 10008 | Oxidation Inhibitor ‐ % - ASTM D‐2668 | 52 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| 10009 | Furan Screen ‐ ppb (When a Furan test is requested, test results must be broken down and list each compound found in the sample (5H2F, 2FOL, 2FAL, 2ACF and 5M2F) and expressed in PPB.) | 180 | EA | 15 | EA | 0 | EA | $ - 0 | ||||
| 10010 | Corrosive Sulphur ‐ ppm - ASTM D‐1275, 3 day test | 1 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| 10011 | *Degree of Polymarization ‐ DP - ASTM D‐4243 | 0 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| 10012 | PCB ‐ ppm - EPA 600 / 4‐81‐045 | 25 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| 10013 | Color ‐ Relative - ASTM D‐1524 | 0 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| 10014 | Dielectric ‐ kV MM‐C - ASTM D‐877 | 0 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| 10015 | Dielectric ‐ kV MM‐C - ASTM D‐1816 | 0 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| 10016 | Acidity (modified) ‐ mg KOH/g - ASTM D‐974 | 0 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| 10017 | Interfacial Tension ‐ dyne/cm - ASTM D‐971 | 0 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| 10018 | Metals in Oil, 8 Metal Scan ‐ ppm - ASTM D‐3635 | 0 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| 10019 | Water in Oil - ASTM D1533 | 10 | EA | 6 | EA | 0 | EA | $ - 0 | ||||
| 10020 | Multi part screen/test (69kV and higher) one test that screens for the following: Color/Visual (ASTM D1500/D1524); Water/RS (ASTMD1533); Dielectric (ASTM D1816); Interfacial Tension (ASTM D971); Power Factor 25Deg C (ASTM D924); Power Factor 100 Deg C (ASTM D924); Specific Gravity (ASTM D1298); Neut. No (ASTM D974) | 410 | EA | 20 | EA | 0 | EA | $ - 0 | ||||
| 10021 | Multi part screen/test (69kV and lower) one test that screens for the following: Color/Visual (ASTM D1500/D1524); Water/RS (ASTMD1533); Dielectric (ASTM D1816); Interfacial Tension (ASTM D971); Power Factor 25Deg C (ASTM D924); Power Factor 100 Deg C (ASTM D924); Specific Gravity (ASTM D1298); Neut. No (ASTM D974) | 50 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| 10022 | Viscosity - ASTM D445 | 0 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| 10023 | Oxidation inhibitor in Natural Esters (FR3 Insulating Fluid) - ASTM D‐4768 | 0 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| OPTION YEAR ONE TOTAL | $ - 0 | |||||||||||
| OPTION YEAR TWO | ||||||||||||
| CLIN | Test name/Description | Est Qty | ||||||||||
| (Routine) | UOM | Unit Price | Est Qty | |||||||||
| (Expedited) | UOM | Unit Price | Est Qty | |||||||||
| (Same Day) | UOM | Unit Price | Total | |||||||||
| 20001 | Transformer Dissolved Gas Analysis - ASTM D‐3612 |
Consisting of following components:
| Hydrogen (H2) ‐ ppm, Methane (CH4) ‐ ppm, Ethane (C2H6) ‐ ppm, Ethylene (C2H4) ‐ ppm, Acetylene (C2H2) ‐ ppm, Carbon Monoxide (CO) ‐ ppm, Carbon Dioxide (C02) ‐ ppm, Nitrogen (N2) ‐ ppm, Oxygen (O2) ‐ ppm, Total Gas ‐ ppm, Total Combustable Gas ‐ ppm, and Equivalent TCG ‐ % | 600 | EA | 15 | EA | 10 | EA | $ - 0 | |
| 20002 | Transformer Physical‐Chemical |
Consisting of following components:
| Moisture in oil ‐ ppm - ASTM D‐1533 B, IFT ‐ dynes/cm - ASTM D‐971, Acid # ‐ mg KOH/g - ASTM D‐974, Color # ‐ relative - ASTM D‐1524, Visual ‐ string - ASTM D‐1524, Dielectric (a) ‐ kV MM‐C - ASTM D‐877, Dielectric (b) ‐kV MM‐C - ASTM D‐1816, Viscosity ‐ SFS (NUMERIC) - ASTM D445 ASTM D‐88, Specific Gravity ‐ relative - ASTM D‐1298, Power Factor @ 25 C ‐ % - ASTM D‐924, Power Factor @ 100 C ‐ % - ASTM D‐924, and Flash Point‐Pour Point ‐ C/F - ASTM D‐92 | 175 | EA | 5 | EA | 5 | EA | $ - 0 | |
| 20003 | Transformer Metals in Oil - ASTM D‐3635 |
Consisting of following components:
Silver (Ag) ‐ ppm, Chromium (Cr) ‐ ppm, Copper (Cu) ‐ ppm, Molybdenium (Mo) ‐ ppm,
| Nickel (Ni) ‐ ppm, Lead (Pb) ‐ ppm, Tin (Sn) ‐ ppm, and Tungsten (W) ‐ ppm | 10 | EA | 0 | EA | 0 | EA | $ - 0 | |
| 20004 | Transformer Fault/Wear Metals in Oil - ASTM D‐7151 |
Consisting of following components:
| Silver (Ag) ‐ ppm, Aluminum (Al) ‐ ppm, Copper (Cu) ‐ ppm, Iron (Fe) ‐ ppm, Silicon (Si) ‐ ppm, Tin (Sn) ‐ ppm, and Zinc (Zn) ‐ ppm | 0 | EA | 0 | EA | 0 | EA | $ - 0 | |
| 20005 | Transformer Pump Wear Metals in Oil - ASTM D‐7151 |
Consisting of following components:
| Silver (Ag) ‐ ppm, Aluminum (Al) ‐ ppm, Barium (Ba) ‐ ppm, Cromium (Cr) ‐ ppm, Copper (Cu) ‐ ppm, Iron (Fe) ‐ ppm, Magnesium (Mg) ‐ ppm, Molybdenum (Mo) ‐ ppm, Nickel (Ni) ‐ ppm, P ‐ ppm, Lead (Pb) ‐ ppm, Silicon (Si) ‐ ppm, Tin (Sn) ‐ ppm, Vandium (V) ‐ ppm, Zinc (Zn) ‐ ppm | 0 | EA | 0 | EA | 0 | EA | $ - 0 | |||||
| 20006 | LOAD TAP CHANGER Consisting of the following components: Transformer Dissolved Gas Analysis ASTM D-3615, Moisture in oil ‐ ppm - ASTM D‐1533 B, IFT ‐ dynes/cm - ASTM D‐971, Acid # ‐ mg KOH/g - ASTM D‐974, Color # ‐ relative - ASTM D‐1524, Visual ‐ string - ASTM D‐1524, Dielectric (a) ‐ kV MM‐C - ASTM D‐877, Dielectric (b) ‐kV MM‐C - ASTM D‐1816, 2,6-di-tert-butyl-Butyl-Phenol/p-Cresol - D-2668; Viscosity ‐ SFS (NUMERIC) - ASTM D-445, Specific Gravity ‐ relative - ASTM D‐1298, Power Factor @ 25 C ‐ % - ASTM D‐924, Power Factor @ 100 C ‐ % - ASTM D‐924, and Flash Point‐Pour Point ‐ C/F - ASTM D‐92, Corrosive Silver - D-1275 (AS NEEDED), Degree of Polmerization - D-4243, PCB (AS NEEDED) Metals in oil - ASTM D-7151, Fault/Wear metals in Oil - ASTM D-7151, Particle - ASTM D-6786, Furanic Compounds- ASTM D-5837 | 45 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| 20007 | Circuit Breaker Oil Analysis (BOA) |
Consisting of following components:
| Dissolved Gas Analysis - ASTM D‐3612, Moisture Content ‐ ppm - ASTM D‐1533b, Power Factor ‐ % @ 25 Centigrade - ASTM D‐924, Power Factor ‐ % @ 100 Centigrade - ASTM D‐924, Particle Characterization Laser Scan/ISO Code ‐ count - ASTM D‐6786, Metals In Oil, 8 Metal Scan, ppm - ASTM D‐3635, Visual string - ASTM D‐1524, Specific Gravity SG ralative - ASTM D‐1298, and Partical Count in Oil: > 4 µm ‐ count, > 6 µm ‐ count, > 10 µm ‐ count, > 14 µm ‐ count, and > 21 µm ‐ count | 7 | EA | 0 | EA | 0 | EA | $ - 0 | |||||
| 20008 | Oxidation Inhibitor ‐ % - ASTM D‐2668 | 52 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| 20009 | Furan Screen ‐ ppb (When a Furan test is requested, test results must be broken down and list each compound found in the sample (5H2F, 2FOL, 2FAL, 2ACF and 5M2F) and expressed in PPB.) | 180 | EA | 15 | EA | 0 | EA | $ - 0 | ||||
| 20010 | Corrosive Sulphur ‐ ppm - ASTM D‐1275, 3 day test | 1 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| 20011 | *Degree of Polymarization ‐ DP - ASTM D‐4243 | 0 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| 20012 | PCB ‐ ppm - EPA 600 / 4‐81‐045 | 25 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| 20013 | Color ‐ Relative - ASTM D‐1524 | 0 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| 20014 | Dielectric ‐ kV MM‐C - ASTM D‐877 | 0 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| 20015 | Dielectric ‐ kV MM‐C - ASTM D‐1816 | 0 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| 20016 | Acidity (modified) ‐ mg KOH/g - ASTM D‐974 | 0 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| 20017 | Interfacial Tension ‐ dyne/cm - ASTM D‐971 | 0 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| 20018 | Metals in Oil, 8 Metal Scan ‐ ppm - ASTM D‐3635 | 0 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| 20019 | Water in Oil - ASTM D1533 | 10 | EA | 6 | EA | 0 | EA | $ - 0 | ||||
| 20020 | Multi part screen/test (69kV and higher) one test that screens for the following: Color/Visual (ASTM D1500/D1524); Water/RS (ASTMD1533); Dielectric (ASTM D1816); Interfacial Tension (ASTM D971); Power Factor 25Deg C (ASTM D924); Power Factor 100 Deg C (ASTM D924); Specific Gravity (ASTM D1298); Neut. No (ASTM D974) | 410 | EA | 20 | EA | 0 | EA | $ - 0 | ||||
| 20021 | Multi part screen/test (69kV and lower) one test that screens for the following: Color/Visual (ASTM D1500/D1524); Water/RS (ASTMD1533); Dielectric (ASTM D1816); Interfacial Tension (ASTM D971); Power Factor 25Deg C (ASTM D924); Power Factor 100 Deg C (ASTM D924); Specific Gravity (ASTM D1298); Neut. No (ASTM D974) | 50 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| 20022 | Viscosity - ASTM D445 | 0 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| 20023 | Oxidation inhibitor in Natural Esters (FR3 Insulating Fluid) - ASTM D‐4768 | 0 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| OPTION YEAR TWO TOTAL | $ - 0 | |||||||||||
| OPTION YEAR THREE | ||||||||||||
| CLIN | Test name/Description | Est Qty | ||||||||||
| (Routine) | UOM | Unit Price | Est Qty | |||||||||
| (Expedited) | UOM | Unit Price | Est Qty | |||||||||
| (Same Day) | UOM | Unit Price | Total | |||||||||
| 30001 | Transformer Dissolved Gas Analysis - ASTM D‐3612 |
Consisting of following components:
| Hydrogen (H2) ‐ ppm, Methane (CH4) ‐ ppm, Ethane (C2H6) ‐ ppm, Ethylene (C2H4) ‐ ppm, Acetylene (C2H2) ‐ ppm, Carbon Monoxide (CO) ‐ ppm, Carbon Dioxide (C02) ‐ ppm, Nitrogen (N2) ‐ ppm, Oxygen (O2) ‐ ppm, Total Gas ‐ ppm, Total Combustable Gas ‐ ppm, and Equivalent TCG ‐ % | 600 | EA | 15 | EA | 10 | EA | $ - 0 | |
| 30002 | Transformer Physical‐Chemical |
Consisting of following components:
| Moisture in oil ‐ ppm - ASTM D‐1533 B, IFT ‐ dynes/cm - ASTM D‐971, Acid # ‐ mg KOH/g - ASTM D‐974, Color # ‐ relative - ASTM D‐1524, Visual ‐ string - ASTM D‐1524, Dielectric (a) ‐ kV MM‐C - ASTM D‐877, Dielectric (b) ‐kV MM‐C - ASTM D‐1816, Viscosity ‐ SFS (NUMERIC) - ASTM D445 ASTM D‐88, Specific Gravity ‐ relative - ASTM D‐1298, Power Factor @ 25 C ‐ % - ASTM D‐924, Power Factor @ 100 C ‐ % - ASTM D‐924, and Flash Point‐Pour Point ‐ C/F - ASTM D‐92 | 175 | EA | 5 | EA | 5 | EA | $ - 0 | |
| 30003 | Transformer Metals in Oil - ASTM D‐3635 |
Consisting of following components:
Silver (Ag) ‐ ppm, Chromium (Cr) ‐ ppm, Copper (Cu) ‐ ppm, Molybdenium (Mo) ‐ ppm,
| Nickel (Ni) ‐ ppm, Lead (Pb) ‐ ppm, Tin (Sn) ‐ ppm, and Tungsten (W) ‐ ppm | 10 | EA | 0 | EA | 0 | EA | $ - 0 | |
| 30004 | Transformer Fault/Wear Metals in Oil - ASTM D‐7151 |
Consisting of following components:
| Silver (Ag) ‐ ppm, Aluminum (Al) ‐ ppm, Copper (Cu) ‐ ppm, Iron (Fe) ‐ ppm, Silicon (Si) ‐ ppm, Tin (Sn) ‐ ppm, and Zinc (Zn) ‐ ppm | 0 | EA | 0 | EA | 0 | EA | $ - 0 | |
| 30005 | Transformer Pump Wear Metals in Oil - ASTM D‐7151 |
Consisting of following components:
| Silver (Ag) ‐ ppm, Aluminum (Al) ‐ ppm, Barium (Ba) ‐ ppm, Cromium (Cr) ‐ ppm, Copper (Cu) ‐ ppm, Iron (Fe) ‐ ppm, Magnesium (Mg) ‐ ppm, Molybdenum (Mo) ‐ ppm, Nickel (Ni) ‐ ppm, P ‐ ppm, Lead (Pb) ‐ ppm, Silicon (Si) ‐ ppm, Tin (Sn) ‐ ppm, Vandium (V) ‐ ppm, Zinc (Zn) ‐ ppm | 0 | EA | 0 | EA | 0 | EA | $ - 0 | |||||
| 30006 | LOAD TAP CHANGER Consisting of the following components: Transformer Dissolved Gas Analysis ASTM D-3615, Moisture in oil ‐ ppm - ASTM D‐1533 B, IFT ‐ dynes/cm - ASTM D‐971, Acid # ‐ mg KOH/g - ASTM D‐974, Color # ‐ relative - ASTM D‐1524, Visual ‐ string - ASTM D‐1524, Dielectric (a) ‐ kV MM‐C - ASTM D‐877, Dielectric (b) ‐kV MM‐C - ASTM D‐1816, 2,6-di-tert-butyl-Butyl-Phenol/p-Cresol - D-2668; Viscosity ‐ SFS (NUMERIC) - ASTM D-445, Specific Gravity ‐ relative - ASTM D‐1298, Power Factor @ 25 C ‐ % - ASTM D‐924, Power Factor @ 100 C ‐ % - ASTM D‐924, and Flash Point‐Pour Point ‐ C/F - ASTM D‐92, Corrosive Silver - D-1275 (AS NEEDED), Degree of Polmerization - D-4243, PCB (AS NEEDED) Metals in oil - ASTM D-7151, Fault/Wear metals in Oil - ASTM D-7151, Particle - ASTM D-6786, Furanic Compounds- ASTM D-5837 | 45 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| 30007 | Circuit Breaker Oil Analysis (BOA) |
Consisting of following components:
| Dissolved Gas Analysis - ASTM D‐3612, Moisture Content ‐ ppm - ASTM D‐1533b, Power Factor ‐ % @ 25 Centigrade - ASTM D‐924, Power Factor ‐ % @ 100 Centigrade - ASTM D‐924, Particle Characterization Laser Scan/ISO Code ‐ count - ASTM D‐6786, Metals In Oil, 8 Metal Scan, ppm - ASTM D‐3635, Visual string - ASTM D‐1524, Specific Gravity SG ralative - ASTM D‐1298, and Partical Count in Oil: > 4 µm ‐ count, > 6 µm ‐ count, > 10 µm ‐ count, > 14 µm ‐ count, and > 21 µm ‐ count | 7 | EA | 0 | EA | 0 | EA | $ - 0 | |||||
| 30008 | Oxidation Inhibitor ‐ % - ASTM D‐2668 | 52 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| 30009 | Furan Screen ‐ ppb (When a Furan test is requested, test results must be broken down and list each compound found in the sample (5H2F, 2FOL, 2FAL, 2ACF and 5M2F) and expressed in PPB.) | 180 | EA | 15 | EA | 0 | EA | $ - 0 | ||||
| 30010 | Corrosive Sulphur ‐ ppm - ASTM D‐1275, 3 day test | 1 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| 30011 | *Degree of Polymarization ‐ DP - ASTM D‐4243 | 0 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| 30012 | PCB ‐ ppm - EPA 600 / 4‐81‐045 | 25 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| 30013 | Color ‐ Relative - ASTM D‐1524 | 0 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| 30014 | Dielectric ‐ kV MM‐C - ASTM D‐877 | 0 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| 30015 | Dielectric ‐ kV MM‐C - ASTM D‐1816 | 0 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| 30016 | Acidity (modified) ‐ mg KOH/g - ASTM D‐974 | 0 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| 30017 | Interfacial Tension ‐ dyne/cm - ASTM D‐971 | 0 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| 30018 | Metals in Oil, 8 Metal Scan ‐ ppm - ASTM D‐3635 | 0 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| 30019 | Water in Oil - ASTM D1533 | 10 | EA | 6 | EA | 0 | EA | $ - 0 | ||||
| 30020 | Multi part screen/test (69kV and higher) one test that screens for the following: Color/Visual (ASTM D1500/D1524); Water/RS (ASTMD1533); Dielectric (ASTM D1816); Interfacial Tension (ASTM D971); Power Factor 25Deg C (ASTM D924); Power Factor 100 Deg C (ASTM D924); Specific Gravity (ASTM D1298); Neut. No (ASTM D974) | 410 | EA | 20 | EA | 0 | EA | $ - 0 | ||||
| 30021 | Multi part screen/test (69kV and lower) one test that screens for the following: Color/Visual (ASTM D1500/D1524); Water/RS (ASTMD1533); Dielectric (ASTM D1816); Interfacial Tension (ASTM D971); Power Factor 25Deg C (ASTM D924); Power Factor 100 Deg C (ASTM D924); Specific Gravity (ASTM D1298); Neut. No (ASTM D974) | 50 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| 30022 | Viscosity - ASTM D445 | 0 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| 30023 | Oxidation inhibitor in Natural Esters (FR3 Insulating Fluid) - ASTM D‐4768 | 0 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| OPTION YEAR THREE TOTAL | $ - 0 | |||||||||||
| OPTION YEAR FOUR | ||||||||||||
| CLIN | Test name/Description | Est Qty | ||||||||||
| (Routine) | UOM | Unit Price | Est Qty | |||||||||
| (Expedited) | UOM | Unit Price | Est Qty | |||||||||
| (Same Day) | UOM | Unit Price | Total | |||||||||
| 40001 | Transformer Dissolved Gas Analysis - ASTM D‐3612 |
Consisting of following components:
| Hydrogen (H2) ‐ ppm, Methane (CH4) ‐ ppm, Ethane (C2H6) ‐ ppm, Ethylene (C2H4) ‐ ppm, Acetylene (C2H2) ‐ ppm, Carbon Monoxide (CO) ‐ ppm, Carbon Dioxide (C02) ‐ ppm, Nitrogen (N2) ‐ ppm, Oxygen (O2) ‐ ppm, Total Gas ‐ ppm, Total Combustable Gas ‐ ppm, and Equivalent TCG ‐ % | 600 | EA | 15 | EA | 10 | EA | $ - 0 | |
| 40002 | Transformer Physical‐Chemical |
Consisting of following components:
| Moisture in oil ‐ ppm - ASTM D‐1533 B, IFT ‐ dynes/cm - ASTM D‐971, Acid # ‐ mg KOH/g - ASTM D‐974, Color # ‐ relative - ASTM D‐1524, Visual ‐ string - ASTM D‐1524, Dielectric (a) ‐ kV MM‐C - ASTM D‐877, Dielectric (b) ‐kV MM‐C - ASTM D‐1816, Viscosity ‐ SFS (NUMERIC) - ASTM D445 ASTM D‐88, Specific Gravity ‐ relative - ASTM D‐1298, Power Factor @ 25 C ‐ % - ASTM D‐924, Power Factor @ 100 C ‐ % - ASTM D‐924, and Flash Point‐Pour Point ‐ C/F - ASTM D‐92 | 175 | EA | 5 | EA | 5 | EA | $ - 0 | |
| 40003 | Transformer Metals in Oil - ASTM D‐3635 |
Consisting of following components:
Silver (Ag) ‐ ppm, Chromium (Cr) ‐ ppm, Copper (Cu) ‐ ppm, Molybdenium (Mo) ‐ ppm,
| Nickel (Ni) ‐ ppm, Lead (Pb) ‐ ppm, Tin (Sn) ‐ ppm, and Tungsten (W) ‐ ppm | 10 | EA | 0 | EA | 0 | EA | $ - 0 | |
| 40004 | Transformer Fault/Wear Metals in Oil - ASTM D‐7151 |
Consisting of following components:
| Silver (Ag) ‐ ppm, Aluminum (Al) ‐ ppm, Copper (Cu) ‐ ppm, Iron (Fe) ‐ ppm, Silicon (Si) ‐ ppm, Tin (Sn) ‐ ppm, and Zinc (Zn) ‐ ppm | 0 | EA | 0 | EA | 0 | EA | $ - 0 | |
| 40005 | Transformer Pump Wear Metals in Oil - ASTM D‐7151 |
Consisting of following components:
| Silver (Ag) ‐ ppm, Aluminum (Al) ‐ ppm, Barium (Ba) ‐ ppm, Cromium (Cr) ‐ ppm, Copper (Cu) ‐ ppm, Iron (Fe) ‐ ppm, Magnesium (Mg) ‐ ppm, Molybdenum (Mo) ‐ ppm, Nickel (Ni) ‐ ppm, P ‐ ppm, Lead (Pb) ‐ ppm, Silicon (Si) ‐ ppm, Tin (Sn) ‐ ppm, Vandium (V) ‐ ppm, Zinc (Zn) ‐ ppm | 0 | EA | 0 | EA | 0 | EA | $ - 0 | |||||
| 40006 | LOAD TAP CHANGER Consisting of the following components: Transformer Dissolved Gas Analysis ASTM D-3615, Moisture in oil ‐ ppm - ASTM D‐1533 B, IFT ‐ dynes/cm - ASTM D‐971, Acid # ‐ mg KOH/g - ASTM D‐974, Color # ‐ relative - ASTM D‐1524, Visual ‐ string - ASTM D‐1524, Dielectric (a) ‐ kV MM‐C - ASTM D‐877, Dielectric (b) ‐kV MM‐C - ASTM D‐1816, 2,6-di-tert-butyl-Butyl-Phenol/p-Cresol - D-2668; Viscosity ‐ SFS (NUMERIC) - ASTM D-445, Specific Gravity ‐ relative - ASTM D‐1298, Power Factor @ 25 C ‐ % - ASTM D‐924, Power Factor @ 100 C ‐ % - ASTM D‐924, and Flash Point‐Pour Point ‐ C/F - ASTM D‐92, Corrosive Silver - D-1275 (AS NEEDED), Degree of Polmerization - D-4243, PCB (AS NEEDED) Metals in oil - ASTM D-7151, Fault/Wear metals in Oil - ASTM D-7151, Particle - ASTM D-6786, Furanic Compounds- ASTM D-5837 | 45 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| 40007 | Circuit Breaker Oil Analysis (BOA) |
Consisting of following components:
| Dissolved Gas Analysis - ASTM D‐3612, Moisture Content ‐ ppm - ASTM D‐1533b, Power Factor ‐ % @ 25 Centigrade - ASTM D‐924, Power Factor ‐ % @ 100 Centigrade - ASTM D‐924, Particle Characterization Laser Scan/ISO Code ‐ count - ASTM D‐6786, Metals In Oil, 8 Metal Scan, ppm - ASTM D‐3635, Visual string - ASTM D‐1524, Specific Gravity SG ralative - ASTM D‐1298, and Partical Count in Oil: > 4 µm ‐ count, > 6 µm ‐ count, > 10 µm ‐ count, > 14 µm ‐ count, and > 21 µm ‐ count | 7 | EA | 0 | EA | 0 | EA | $ - 0 | |||||
| 40008 | Oxidation Inhibitor ‐ % - ASTM D‐2668 | 52 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| 40009 | Furan Screen ‐ ppb (When a Furan test is requested, test results must be broken down and list each compound found in the sample (5H2F, 2FOL, 2FAL, 2ACF and 5M2F) and expressed in PPB.) | 180 | EA | 15 | EA | 0 | EA | $ - 0 | ||||
| 40010 | Corrosive Sulphur ‐ ppm - ASTM D‐1275, 3 day test | 1 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| 40011 | *Degree of Polymarization ‐ DP - ASTM D‐4243 | 0 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| 40012 | PCB ‐ ppm - EPA 600 / 4‐81‐045 | 25 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| 40013 | Color ‐ Relative - ASTM D‐1524 | 0 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| 40014 | Dielectric ‐ kV MM‐C - ASTM D‐877 | 0 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| 40015 | Dielectric ‐ kV MM‐C - ASTM D‐1816 | 0 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| 40016 | Acidity (modified) ‐ mg KOH/g - ASTM D‐974 | 0 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| 40017 | Interfacial Tension ‐ dyne/cm - ASTM D‐971 | 0 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| 40018 | Metals in Oil, 8 Metal Scan ‐ ppm - ASTM D‐3635 | 0 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| 40019 | Water in Oil - ASTM D1533 | 10 | EA | 6 | EA | 0 | EA | $ - 0 | ||||
| 40020 | Multi part screen/test (69kV and higher) one test that screens for the following: Color/Visual (ASTM D1500/D1524); Water/RS (ASTMD1533); Dielectric (ASTM D1816); Interfacial Tension (ASTM D971); Power Factor 25Deg C (ASTM D924); Power Factor 100 Deg C (ASTM D924); Specific Gravity (ASTM D1298); Neut. No (ASTM D974) | 410 | EA | 20 | EA | 0 | EA | $ - 0 | ||||
| 40021 | Multi part screen/test (69kV and lower) one test that screens for the following: Color/Visual (ASTM D1500/D1524); Water/RS (ASTMD1533); Dielectric (ASTM D1816); Interfacial Tension (ASTM D971); Power Factor 25Deg C (ASTM D924); Power Factor 100 Deg C (ASTM D924); Specific Gravity (ASTM D1298); Neut. No (ASTM D974) | 50 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| 40022 | Viscosity - ASTM D445 | 0 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| 40023 | Oxidation inhibitor in Natural Esters (FR3 Insulating Fluid) - ASTM D‐4768 | 0 | EA | 0 | EA | 0 | EA | $ - 0 | ||||
| OPTION YEAR FOUR TOTAL | $ - 0 |
TOTAL ESTIMATED CONTRACT VALUE $ - 0
Independent Cost Estimate
All quantities are estimates only, not a guarantee *If not included in a separate test. If included in a separate test, no additional charge