18. Attachment B - Pricing Schedule.xlsx

XLSX spreadsheet 25 KB Posted

Attached to
OIL SAMPLE ANALYSIS AND TESTING - HIGH VOLTAGE TRANSFORMERS
Solicitation number
89503221QWA000352
Issued by

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Table 1 ATTACHMENT B - RFQ 89503221QWA000352 - Schedule of Supplies/Services and Prices/Costs *ANY TEST NOT AVAILABLE FOR EXPEDITED AND/OR SAME DAY TESTING SHALL BE NOTED BY THE OFFEROR All quanities are estimates only and not a guarantee IF ESTIMATED QUANTITY IS ZERO, PROVIDE PRICING IN THE EVENT TEST BECOMES NEEDED IN THE FUTURE

CLINTest name/DescriptionEst Qty
(Routine)UOMUnit PriceEst Qty
(Expedited)UOMUnit PriceEst Qty
(Same Day)UOMUnit PriceTotal
BASE YEAR
00001Transformer Dissolved Gas Analysis - ASTM D‐3612

Consisting of following components:

Hydrogen (H2) ‐ ppm, Methane (CH4) ‐ ppm, Ethane (C2H6) ‐ ppm, Ethylene (C2H4) ‐ ppm, Acetylene (C2H2) ‐ ppm, Carbon Monoxide (CO) ‐ ppm, Carbon Dioxide (C02) ‐ ppm, Nitrogen (N2) ‐ ppm, Oxygen (O2) ‐ ppm, Total Gas ‐ ppm, Total Combustable Gas ‐ ppm, and Equivalent TCG ‐ %600EA15EA10EA$ - 0
00002Transformer Physical‐Chemical

Consisting of following components:

Moisture in oil ‐ ppm - ASTM D‐1533 B, IFT ‐ dynes/cm - ASTM D‐971, Acid # ‐ mg KOH/g - ASTM D‐974, Color # ‐ relative - ASTM D‐1524, Visual ‐ string - ASTM D‐1524, Dielectric (a) ‐ kV MM‐C - ASTM D‐877, Dielectric (b) ‐kV MM‐C - ASTM D‐1816, Viscosity ‐ SFS (NUMERIC) - ASTM D‐88, Specific Gravity ‐ relative - ASTM D‐1298, Power Factor @ 25 C ‐ % - ASTM D‐924, Power Factor @ 100 C ‐ % - ASTM D‐924, and Flash Point‐Pour Point ‐ C/F - ASTM D‐92175EA5EA5EA$ - 0
00003Transformer Metals in Oil - ASTM D‐3635

Consisting of following components:

Silver (Ag) ‐ ppm, Chromium (Cr) ‐ ppm, Copper (Cu) ‐ ppm, Molybdenium (Mo) ‐ ppm,

Nickel (Ni) ‐ ppm, Lead (Pb) ‐ ppm, Tin (Sn) ‐ ppm, and Tungsten (W) ‐ ppm10EA0EA0EA$ - 0
00004Transformer Fault/Wear Metals in Oil - ASTM D‐7151

Consisting of following components:

Silver (Ag) ‐ ppm, Aluminum (Al) ‐ ppm, Copper (Cu) ‐ ppm, Iron (Fe) ‐ ppm, Silicon (Si) ‐ ppm, Tin (Sn) ‐ ppm, and Zinc (Zn) ‐ ppm0EA0EA0EA$ - 0
00005Transformer Pump Wear Metals in Oil - ASTM D‐7151

Consisting of following components:

Silver (Ag) ‐ ppm, Aluminum (Al) ‐ ppm, Barium (Ba) ‐ ppm, Cromium (Cr) ‐ ppm, Copper (Cu) ‐ ppm, Iron (Fe) ‐ ppm, Magnesium (Mg) ‐ ppm, Molybdenum (Mo) ‐ ppm, Nickel (Ni) ‐ ppm, P ‐ ppm, Lead (Pb) ‐ ppm, Silicon (Si) ‐ ppm, Tin (Sn) ‐ ppm, Vandium (V) ‐ ppm, Zinc (Zn) ‐ ppm0EA0EA0EA$ - 0
00006LOAD TAP CHANGER45EA0EA0EA$ - 0
00007Circuit Breaker Oil Analysis (BOA)

Consisting of following components:

Dissolved Gas Analysis - ASTM D‐3612, Moisture Content ‐ ppm - ASTM D‐1533b, Power Factor ‐ % @ 25 Centigrade - ASTM D‐924, Power Factor ‐ % @ 100 Centigrade - ASTM D‐924, Particle Characterization Laser Scan/ISO Code ‐ count - ASTM D‐6786, Metals In Oil, 8 Metal Scan, ppm - ASTM D‐3635, Visual string - ASTM D‐1524, Specific Gravity SG ralative - ASTM D‐1298, and Partical Count in Oil: > 4 µm ‐ count, > 6 µm ‐ count, > 10 µm ‐ count, > 14 µm ‐ count, and > 21 µm ‐ count7EA0EA0EA$ - 0
00008Oxidation Inhibitor ‐ % - ASTM D‐266852EA0EA0EA$ - 0
00009Furan Screen ‐ ppb (When a Furan test is requested, test results must be broken down and list each compound found in the sample (5H2F, 2FOL, 2FAL, 2ACF and 5M2F) and expressed in PPB.)180EA15EA0EA$ - 0
00010Corrosive Sulphur ‐ ppm - ASTM D‐1275, 3 day test1EA0EA0EA$ - 0
00011*Degree of Polymarization ‐ DP - ASTM D‐42430EA0EA0EA$ - 0
00012PCB ‐ ppm - EPA 600 / 4‐81‐04525EA0EA0EA$ - 0
00013Color ‐ Relative - ASTM D‐15240EA0EA0EA$ - 0
00014Dielectric ‐ kV MM‐C - ASTM D‐8770EA0EA0EA$ - 0
00015Dielectric ‐ kV MM‐C - ASTM D‐18160EA0EA0EA$ - 0
00016Acidity (modified) ‐ mg KOH/g - ASTM D‐9740EA0EA0EA$ - 0
00017Interfacial Tension ‐ dyne/cm - ASTM D‐9710EA0EA0EA$ - 0
00018Metals in Oil, 8 Metal Scan ‐ ppm - ASTM D‐36350EA0EA0EA$ - 0
00019Water in Oil - ASTM D153310EA6EA0EA$ - 0
00020Multi part screen/test (69kV and higher) one test that screens for the following: Color/Visual (ASTM D1500/D1524); Water/RS (ASTMD1533); Dielectric (ASTM D1816); Interfacial Tension (ASTM D971); Power Factor 25Deg C (ASTM D924); Power Factor 100 Deg C (ASTM D924); Specific Gravity (ASTM D1298); Neut. No (ASTM D974)410EA20EA0EA$ - 0
00021Multi part screen/test (69kV and lower) one test that screens for the following: Color/Visual (ASTM D1500/D1524); Water/RS (ASTMD1533); Dielectric (ASTM D1816); Interfacial Tension (ASTM D971); Power Factor 25Deg C (ASTM D924); Power Factor 100 Deg C (ASTM D924); Specific Gravity (ASTM D1298); Neut. No (ASTM D974)50EA0EA0EA$ - 0
00022Viscosity - ASTM D4450EA0EA0EA$ - 0
00023Oxidation inhibitor in Natural Esters (FR3 Insulating Fluid) - ASTM D‐47680EA0EA0EA$ - 0
BASE YEAR TOTAL$ - 0
OPTION YEAR ONE
CLINTest name/DescriptionEst Qty
(Routine)UOMUnit PriceEst Qty
(Expedited)UOMUnit PriceEst Qty
(Same Day)UOMUnit PriceTotal
10001Transformer Dissolved Gas Analysis - ASTM D‐3612

Consisting of following components:

Hydrogen (H2) ‐ ppm, Methane (CH4) ‐ ppm, Ethane (C2H6) ‐ ppm, Ethylene (C2H4) ‐ ppm, Acetylene (C2H2) ‐ ppm, Carbon Monoxide (CO) ‐ ppm, Carbon Dioxide (C02) ‐ ppm, Nitrogen (N2) ‐ ppm, Oxygen (O2) ‐ ppm, Total Gas ‐ ppm, Total Combustable Gas ‐ ppm, and Equivalent TCG ‐ %600EA15EA10EA$ - 0
10002Transformer Physical‐Chemical

Consisting of following components:

Moisture in oil ‐ ppm - ASTM D‐1533 B, IFT ‐ dynes/cm - ASTM D‐971, Acid # ‐ mg KOH/g - ASTM D‐974, Color # ‐ relative - ASTM D‐1524, Visual ‐ string - ASTM D‐1524, Dielectric (a) ‐ kV MM‐C - ASTM D‐877, Dielectric (b) ‐kV MM‐C - ASTM D‐1816, Viscosity ‐ SFS (NUMERIC) - ASTM D‐88, Specific Gravity ‐ relative - ASTM D‐1298, Power Factor @ 25 C ‐ % - ASTM D‐924, Power Factor @ 100 C ‐ % - ASTM D‐924, and Flash Point‐Pour Point ‐ C/F - ASTM D‐92175EA5EA5EA$ - 0
10003Transformer Metals in Oil - ASTM D‐3635

Consisting of following components:

Silver (Ag) ‐ ppm, Chromium (Cr) ‐ ppm, Copper (Cu) ‐ ppm, Molybdenium (Mo) ‐ ppm,

Nickel (Ni) ‐ ppm, Lead (Pb) ‐ ppm, Tin (Sn) ‐ ppm, and Tungsten (W) ‐ ppm10EA0EA0EA$ - 0
10004Transformer Fault/Wear Metals in Oil - ASTM D‐7151

Consisting of following components:

Silver (Ag) ‐ ppm, Aluminum (Al) ‐ ppm, Copper (Cu) ‐ ppm, Iron (Fe) ‐ ppm, Silicon (Si) ‐ ppm, Tin (Sn) ‐ ppm, and Zinc (Zn) ‐ ppm0EA0EA0EA$ - 0
10005Transformer Pump Wear Metals in Oil - ASTM D‐7151

Consisting of following components:

Silver (Ag) ‐ ppm, Aluminum (Al) ‐ ppm, Barium (Ba) ‐ ppm, Cromium (Cr) ‐ ppm, Copper (Cu) ‐ ppm, Iron (Fe) ‐ ppm, Magnesium (Mg) ‐ ppm, Molybdenum (Mo) ‐ ppm, Nickel (Ni) ‐ ppm, P ‐ ppm, Lead (Pb) ‐ ppm, Silicon (Si) ‐ ppm, Tin (Sn) ‐ ppm, Vandium (V) ‐ ppm, Zinc (Zn) ‐ ppm0EA0EA0EA$ - 0
10006LOAD TAP CHANGER45EA0EA0EA$ - 0
10007Circuit Breaker Oil Analysis (BOA)

Consisting of following components:

Dissolved Gas Analysis - ASTM D‐3612, Moisture Content ‐ ppm - ASTM D‐1533b, Power Factor ‐ % @ 25 Centigrade - ASTM D‐924, Power Factor ‐ % @ 100 Centigrade - ASTM D‐924, Particle Characterization Laser Scan/ISO Code ‐ count - ASTM D‐6786, Metals In Oil, 8 Metal Scan, ppm - ASTM D‐3635, Visual string - ASTM D‐1524, Specific Gravity SG ralative - ASTM D‐1298, and Partical Count in Oil: > 4 µm ‐ count, > 6 µm ‐ count, > 10 µm ‐ count, > 14 µm ‐ count, and > 21 µm ‐ count7EA0EA0EA$ - 0
10008Oxidation Inhibitor ‐ % - ASTM D‐266852EA0EA0EA$ - 0
10009Furan Screen ‐ ppb (When a Furan test is requested, test results must be broken down and list each compound found in the sample (5H2F, 2FOL, 2FAL, 2ACF and 5M2F) and expressed in PPB.)180EA15EA0EA$ - 0
10010Corrosive Sulphur ‐ ppm - ASTM D‐1275, 3 day test1EA0EA0EA$ - 0
10011*Degree of Polymarization ‐ DP - ASTM D‐42430EA0EA0EA$ - 0
10012PCB ‐ ppm - EPA 600 / 4‐81‐04525EA0EA0EA$ - 0
10013Color ‐ Relative - ASTM D‐15240EA0EA0EA$ - 0
10014Dielectric ‐ kV MM‐C - ASTM D‐8770EA0EA0EA$ - 0
10015Dielectric ‐ kV MM‐C - ASTM D‐18160EA0EA0EA$ - 0
10016Acidity (modified) ‐ mg KOH/g - ASTM D‐9740EA0EA0EA$ - 0
10017Interfacial Tension ‐ dyne/cm - ASTM D‐9710EA0EA0EA$ - 0
10018Metals in Oil, 8 Metal Scan ‐ ppm - ASTM D‐36350EA0EA0EA$ - 0
10019Water in Oil - ASTM D153310EA6EA0EA$ - 0
10020Multi part screen/test (69kV and higher) one test that screens for the following: Color/Visual (ASTM D1500/D1524); Water/RS (ASTMD1533); Dielectric (ASTM D1816); Interfacial Tension (ASTM D971); Power Factor 25Deg C (ASTM D924); Power Factor 100 Deg C (ASTM D924); Specific Gravity (ASTM D1298); Neut. No (ASTM D974)410EA20EA0EA$ - 0
10021Multi part screen/test (69kV and lower) one test that screens for the following: Color/Visual (ASTM D1500/D1524); Water/RS (ASTMD1533); Dielectric (ASTM D1816); Interfacial Tension (ASTM D971); Power Factor 25Deg C (ASTM D924); Power Factor 100 Deg C (ASTM D924); Specific Gravity (ASTM D1298); Neut. No (ASTM D974)50EA0EA0EA$ - 0
10022Viscosity - ASTM D4450EA0EA0EA$ - 0
10023Oxidation inhibitor in Natural Esters (FR3 Insulating Fluid) - ASTM D‐47680EA0EA0EA$ - 0
OPTION YEAR ONE TOTAL$ - 0
OPTION YEAR TWO
CLINTest name/DescriptionEst Qty
(Routine)UOMUnit PriceEst Qty
(Expedited)UOMUnit PriceEst Qty
(Same Day)UOMUnit PriceTotal
20001Transformer Dissolved Gas Analysis - ASTM D‐3612

Consisting of following components:

Hydrogen (H2) ‐ ppm, Methane (CH4) ‐ ppm, Ethane (C2H6) ‐ ppm, Ethylene (C2H4) ‐ ppm, Acetylene (C2H2) ‐ ppm, Carbon Monoxide (CO) ‐ ppm, Carbon Dioxide (C02) ‐ ppm, Nitrogen (N2) ‐ ppm, Oxygen (O2) ‐ ppm, Total Gas ‐ ppm, Total Combustable Gas ‐ ppm, and Equivalent TCG ‐ %600EA15EA10EA$ - 0
20002Transformer Physical‐Chemical

Consisting of following components:

Moisture in oil ‐ ppm - ASTM D‐1533 B, IFT ‐ dynes/cm - ASTM D‐971, Acid # ‐ mg KOH/g - ASTM D‐974, Color # ‐ relative - ASTM D‐1524, Visual ‐ string - ASTM D‐1524, Dielectric (a) ‐ kV MM‐C - ASTM D‐877, Dielectric (b) ‐kV MM‐C - ASTM D‐1816, Viscosity ‐ SFS (NUMERIC) - ASTM D‐88, Specific Gravity ‐ relative - ASTM D‐1298, Power Factor @ 25 C ‐ % - ASTM D‐924, Power Factor @ 100 C ‐ % - ASTM D‐924, and Flash Point‐Pour Point ‐ C/F - ASTM D‐92175EA5EA5EA$ - 0
20003Transformer Metals in Oil - ASTM D‐3635

Consisting of following components:

Silver (Ag) ‐ ppm, Chromium (Cr) ‐ ppm, Copper (Cu) ‐ ppm, Molybdenium (Mo) ‐ ppm,

Nickel (Ni) ‐ ppm, Lead (Pb) ‐ ppm, Tin (Sn) ‐ ppm, and Tungsten (W) ‐ ppm10EA0EA0EA$ - 0
20004Transformer Fault/Wear Metals in Oil - ASTM D‐7151

Consisting of following components:

Silver (Ag) ‐ ppm, Aluminum (Al) ‐ ppm, Copper (Cu) ‐ ppm, Iron (Fe) ‐ ppm, Silicon (Si) ‐ ppm, Tin (Sn) ‐ ppm, and Zinc (Zn) ‐ ppm0EA0EA0EA$ - 0
20005Transformer Pump Wear Metals in Oil - ASTM D‐7151

Consisting of following components:

Silver (Ag) ‐ ppm, Aluminum (Al) ‐ ppm, Barium (Ba) ‐ ppm, Cromium (Cr) ‐ ppm, Copper (Cu) ‐ ppm, Iron (Fe) ‐ ppm, Magnesium (Mg) ‐ ppm, Molybdenum (Mo) ‐ ppm, Nickel (Ni) ‐ ppm, P ‐ ppm, Lead (Pb) ‐ ppm, Silicon (Si) ‐ ppm, Tin (Sn) ‐ ppm, Vandium (V) ‐ ppm, Zinc (Zn) ‐ ppm0EA0EA0EA$ - 0
20006LOAD TAP CHANGER45EA0EA0EA$ - 0
20007Circuit Breaker Oil Analysis (BOA)

Consisting of following components:

Dissolved Gas Analysis - ASTM D‐3612, Moisture Content ‐ ppm - ASTM D‐1533b, Power Factor ‐ % @ 25 Centigrade - ASTM D‐924, Power Factor ‐ % @ 100 Centigrade - ASTM D‐924, Particle Characterization Laser Scan/ISO Code ‐ count - ASTM D‐6786, Metals In Oil, 8 Metal Scan, ppm - ASTM D‐3635, Visual string - ASTM D‐1524, Specific Gravity SG ralative - ASTM D‐1298, and Partical Count in Oil: > 4 µm ‐ count, > 6 µm ‐ count, > 10 µm ‐ count, > 14 µm ‐ count, and > 21 µm ‐ count7EA0EA0EA$ - 0
20008Oxidation Inhibitor ‐ % - ASTM D‐266852EA0EA0EA$ - 0
20009Furan Screen ‐ ppb (When a Furan test is requested, test results must be broken down and list each compound found in the sample (5H2F, 2FOL, 2FAL, 2ACF and 5M2F) and expressed in PPB.)180EA15EA0EA$ - 0
20010Corrosive Sulphur ‐ ppm - ASTM D‐1275, 3 day test1EA0EA0EA$ - 0
20011*Degree of Polymarization ‐ DP - ASTM D‐42430EA0EA0EA$ - 0
20012PCB ‐ ppm - EPA 600 / 4‐81‐04525EA0EA0EA$ - 0
20013Color ‐ Relative - ASTM D‐15240EA0EA0EA$ - 0
20014Dielectric ‐ kV MM‐C - ASTM D‐8770EA0EA0EA$ - 0
20015Dielectric ‐ kV MM‐C - ASTM D‐18160EA0EA0EA$ - 0
20016Acidity (modified) ‐ mg KOH/g - ASTM D‐9740EA0EA0EA$ - 0
20017Interfacial Tension ‐ dyne/cm - ASTM D‐9710EA0EA0EA$ - 0
20018Metals in Oil, 8 Metal Scan ‐ ppm - ASTM D‐36350EA0EA0EA$ - 0
20019Water in Oil - ASTM D153310EA6EA0EA$ - 0
20020Multi part screen/test (69kV and higher) one test that screens for the following: Color/Visual (ASTM D1500/D1524); Water/RS (ASTMD1533); Dielectric (ASTM D1816); Interfacial Tension (ASTM D971); Power Factor 25Deg C (ASTM D924); Power Factor 100 Deg C (ASTM D924); Specific Gravity (ASTM D1298); Neut. No (ASTM D974)410EA20EA0EA$ - 0
20021Multi part screen/test (69kV and lower) one test that screens for the following: Color/Visual (ASTM D1500/D1524); Water/RS (ASTMD1533); Dielectric (ASTM D1816); Interfacial Tension (ASTM D971); Power Factor 25Deg C (ASTM D924); Power Factor 100 Deg C (ASTM D924); Specific Gravity (ASTM D1298); Neut. No (ASTM D974)50EA0EA0EA$ - 0
20022Viscosity - ASTM D4450EA0EA0EA$ - 0
20023Oxidation inhibitor in Natural Esters (FR3 Insulating Fluid) - ASTM D‐47680EA0EA0EA$ - 0
OPTION YEAR TWO TOTAL$ - 0
OPTION YEAR THREE
CLINTest name/DescriptionEst Qty
(Routine)UOMUnit PriceEst Qty
(Expedited)UOMUnit PriceEst Qty
(Same Day)UOMUnit PriceTotal
30001Transformer Dissolved Gas Analysis - ASTM D‐3612

Consisting of following components:

Hydrogen (H2) ‐ ppm, Methane (CH4) ‐ ppm, Ethane (C2H6) ‐ ppm, Ethylene (C2H4) ‐ ppm, Acetylene (C2H2) ‐ ppm, Carbon Monoxide (CO) ‐ ppm, Carbon Dioxide (C02) ‐ ppm, Nitrogen (N2) ‐ ppm, Oxygen (O2) ‐ ppm, Total Gas ‐ ppm, Total Combustable Gas ‐ ppm, and Equivalent TCG ‐ %600EA15EA10EA$ - 0
30002Transformer Physical‐Chemical

Consisting of following components:

Moisture in oil ‐ ppm - ASTM D‐1533 B, IFT ‐ dynes/cm - ASTM D‐971, Acid # ‐ mg KOH/g - ASTM D‐974, Color # ‐ relative - ASTM D‐1524, Visual ‐ string - ASTM D‐1524, Dielectric (a) ‐ kV MM‐C - ASTM D‐877, Dielectric (b) ‐kV MM‐C - ASTM D‐1816, Viscosity ‐ SFS (NUMERIC) - ASTM D‐88, Specific Gravity ‐ relative - ASTM D‐1298, Power Factor @ 25 C ‐ % - ASTM D‐924, Power Factor @ 100 C ‐ % - ASTM D‐924, and Flash Point‐Pour Point ‐ C/F - ASTM D‐92175EA5EA5EA$ - 0
30003Transformer Metals in Oil - ASTM D‐3635

Consisting of following components:

Silver (Ag) ‐ ppm, Chromium (Cr) ‐ ppm, Copper (Cu) ‐ ppm, Molybdenium (Mo) ‐ ppm,

Nickel (Ni) ‐ ppm, Lead (Pb) ‐ ppm, Tin (Sn) ‐ ppm, and Tungsten (W) ‐ ppm10EA0EA0EA$ - 0
30004Transformer Fault/Wear Metals in Oil - ASTM D‐7151

Consisting of following components:

Silver (Ag) ‐ ppm, Aluminum (Al) ‐ ppm, Copper (Cu) ‐ ppm, Iron (Fe) ‐ ppm, Silicon (Si) ‐ ppm, Tin (Sn) ‐ ppm, and Zinc (Zn) ‐ ppm0EA0EA0EA$ - 0
30005Transformer Pump Wear Metals in Oil - ASTM D‐7151

Consisting of following components:

Silver (Ag) ‐ ppm, Aluminum (Al) ‐ ppm, Barium (Ba) ‐ ppm, Cromium (Cr) ‐ ppm, Copper (Cu) ‐ ppm, Iron (Fe) ‐ ppm, Magnesium (Mg) ‐ ppm, Molybdenum (Mo) ‐ ppm, Nickel (Ni) ‐ ppm, P ‐ ppm, Lead (Pb) ‐ ppm, Silicon (Si) ‐ ppm, Tin (Sn) ‐ ppm, Vandium (V) ‐ ppm, Zinc (Zn) ‐ ppm0EA0EA0EA$ - 0
30006LOAD TAP CHANGER45EA0EA0EA$ - 0
30007Circuit Breaker Oil Analysis (BOA)

Consisting of following components:

Dissolved Gas Analysis - ASTM D‐3612, Moisture Content ‐ ppm - ASTM D‐1533b, Power Factor ‐ % @ 25 Centigrade - ASTM D‐924, Power Factor ‐ % @ 100 Centigrade - ASTM D‐924, Particle Characterization Laser Scan/ISO Code ‐ count - ASTM D‐6786, Metals In Oil, 8 Metal Scan, ppm - ASTM D‐3635, Visual string - ASTM D‐1524, Specific Gravity SG ralative - ASTM D‐1298, and Partical Count in Oil: > 4 µm ‐ count, > 6 µm ‐ count, > 10 µm ‐ count, > 14 µm ‐ count, and > 21 µm ‐ count7EA0EA0EA$ - 0
30008Oxidation Inhibitor ‐ % - ASTM D‐266852EA0EA0EA$ - 0
30009Furan Screen ‐ ppb (When a Furan test is requested, test results must be broken down and list each compound found in the sample (5H2F, 2FOL, 2FAL, 2ACF and 5M2F) and expressed in PPB.)180EA15EA0EA$ - 0
30010Corrosive Sulphur ‐ ppm - ASTM D‐1275, 3 day test1EA0EA0EA$ - 0
30011*Degree of Polymarization ‐ DP - ASTM D‐42430EA0EA0EA$ - 0
30012PCB ‐ ppm - EPA 600 / 4‐81‐04525EA0EA0EA$ - 0
30013Color ‐ Relative - ASTM D‐15240EA0EA0EA$ - 0
30014Dielectric ‐ kV MM‐C - ASTM D‐8770EA0EA0EA$ - 0
30015Dielectric ‐ kV MM‐C - ASTM D‐18160EA0EA0EA$ - 0
30016Acidity (modified) ‐ mg KOH/g - ASTM D‐9740EA0EA0EA$ - 0
30017Interfacial Tension ‐ dyne/cm - ASTM D‐9710EA0EA0EA$ - 0
30018Metals in Oil, 8 Metal Scan ‐ ppm - ASTM D‐36350EA0EA0EA$ - 0
30019Water in Oil - ASTM D153310EA6EA0EA$ - 0
30020Multi part screen/test (69kV and higher) one test that screens for the following: Color/Visual (ASTM D1500/D1524); Water/RS (ASTMD1533); Dielectric (ASTM D1816); Interfacial Tension (ASTM D971); Power Factor 25Deg C (ASTM D924); Power Factor 100 Deg C (ASTM D924); Specific Gravity (ASTM D1298); Neut. No (ASTM D974)410EA20EA0EA$ - 0
30021Multi part screen/test (69kV and lower) one test that screens for the following: Color/Visual (ASTM D1500/D1524); Water/RS (ASTMD1533); Dielectric (ASTM D1816); Interfacial Tension (ASTM D971); Power Factor 25Deg C (ASTM D924); Power Factor 100 Deg C (ASTM D924); Specific Gravity (ASTM D1298); Neut. No (ASTM D974)50EA0EA0EA$ - 0
30022Viscosity - ASTM D4450EA0EA0EA$ - 0
30023Oxidation inhibitor in Natural Esters (FR3 Insulating Fluid) - ASTM D‐47680EA0EA0EA$ - 0
OPTION YEAR THREE TOTAL$ - 0
OPTION YEAR FOUR
CLINTest name/DescriptionEst Qty
(Routine)UOMUnit PriceEst Qty
(Expedited)UOMUnit PriceEst Qty
(Same Day)UOMUnit PriceTotal
40001Transformer Dissolved Gas Analysis - ASTM D‐3612

Consisting of following components:

Hydrogen (H2) ‐ ppm, Methane (CH4) ‐ ppm, Ethane (C2H6) ‐ ppm, Ethylene (C2H4) ‐ ppm, Acetylene (C2H2) ‐ ppm, Carbon Monoxide (CO) ‐ ppm, Carbon Dioxide (C02) ‐ ppm, Nitrogen (N2) ‐ ppm, Oxygen (O2) ‐ ppm, Total Gas ‐ ppm, Total Combustable Gas ‐ ppm, and Equivalent TCG ‐ %600EA15EA10EA$ - 0
40002Transformer Physical‐Chemical

Consisting of following components:

Moisture in oil ‐ ppm - ASTM D‐1533 B, IFT ‐ dynes/cm - ASTM D‐971, Acid # ‐ mg KOH/g - ASTM D‐974, Color # ‐ relative - ASTM D‐1524, Visual ‐ string - ASTM D‐1524, Dielectric (a) ‐ kV MM‐C - ASTM D‐877, Dielectric (b) ‐kV MM‐C - ASTM D‐1816, Viscosity ‐ SFS (NUMERIC) - ASTM D‐88, Specific Gravity ‐ relative - ASTM D‐1298, Power Factor @ 25 C ‐ % - ASTM D‐924, Power Factor @ 100 C ‐ % - ASTM D‐924, and Flash Point‐Pour Point ‐ C/F - ASTM D‐92175EA5EA5EA$ - 0
40003Transformer Metals in Oil - ASTM D‐3635

Consisting of following components:

Silver (Ag) ‐ ppm, Chromium (Cr) ‐ ppm, Copper (Cu) ‐ ppm, Molybdenium (Mo) ‐ ppm,

Nickel (Ni) ‐ ppm, Lead (Pb) ‐ ppm, Tin (Sn) ‐ ppm, and Tungsten (W) ‐ ppm10EA0EA0EA$ - 0
40004Transformer Fault/Wear Metals in Oil - ASTM D‐7151

Consisting of following components:

Silver (Ag) ‐ ppm, Aluminum (Al) ‐ ppm, Copper (Cu) ‐ ppm, Iron (Fe) ‐ ppm, Silicon (Si) ‐ ppm, Tin (Sn) ‐ ppm, and Zinc (Zn) ‐ ppm0EA0EA0EA$ - 0
40005Transformer Pump Wear Metals in Oil - ASTM D‐7151

Consisting of following components:

Silver (Ag) ‐ ppm, Aluminum (Al) ‐ ppm, Barium (Ba) ‐ ppm, Cromium (Cr) ‐ ppm, Copper (Cu) ‐ ppm, Iron (Fe) ‐ ppm, Magnesium (Mg) ‐ ppm, Molybdenum (Mo) ‐ ppm, Nickel (Ni) ‐ ppm, P ‐ ppm, Lead (Pb) ‐ ppm, Silicon (Si) ‐ ppm, Tin (Sn) ‐ ppm, Vandium (V) ‐ ppm, Zinc (Zn) ‐ ppm0EA0EA0EA$ - 0
40006LOAD TAP CHANGER45EA0EA0EA$ - 0
40007Circuit Breaker Oil Analysis (BOA)

Consisting of following components:

Dissolved Gas Analysis - ASTM D‐3612, Moisture Content ‐ ppm - ASTM D‐1533b, Power Factor ‐ % @ 25 Centigrade - ASTM D‐924, Power Factor ‐ % @ 100 Centigrade - ASTM D‐924, Particle Characterization Laser Scan/ISO Code ‐ count - ASTM D‐6786, Metals In Oil, 8 Metal Scan, ppm - ASTM D‐3635, Visual string - ASTM D‐1524, Specific Gravity SG ralative - ASTM D‐1298, and Partical Count in Oil: > 4 µm ‐ count, > 6 µm ‐ count, > 10 µm ‐ count, > 14 µm ‐ count, and > 21 µm ‐ count7EA0EA0EA$ - 0
40008Oxidation Inhibitor ‐ % - ASTM D‐266852EA0EA0EA$ - 0
40009Furan Screen ‐ ppb (When a Furan test is requested, test results must be broken down and list each compound found in the sample (5H2F, 2FOL, 2FAL, 2ACF and 5M2F) and expressed in PPB.)180EA15EA0EA$ - 0
40010Corrosive Sulphur ‐ ppm - ASTM D‐1275, 3 day test1EA0EA0EA$ - 0
40011*Degree of Polymarization ‐ DP - ASTM D‐42430EA0EA0EA$ - 0
40012PCB ‐ ppm - EPA 600 / 4‐81‐04525EA0EA0EA$ - 0
40013Color ‐ Relative - ASTM D‐15240EA0EA0EA$ - 0
40014Dielectric ‐ kV MM‐C - ASTM D‐8770EA0EA0EA$ - 0
40015Dielectric ‐ kV MM‐C - ASTM D‐18160EA0EA0EA$ - 0
40016Acidity (modified) ‐ mg KOH/g - ASTM D‐9740EA0EA0EA$ - 0
40017Interfacial Tension ‐ dyne/cm - ASTM D‐9710EA0EA0EA$ - 0
40018Metals in Oil, 8 Metal Scan ‐ ppm - ASTM D‐36350EA0EA0EA$ - 0
40019Water in Oil - ASTM D153310EA6EA0EA$ - 0
40020Multi part screen/test (69kV and higher) one test that screens for the following: Color/Visual (ASTM D1500/D1524); Water/RS (ASTMD1533); Dielectric (ASTM D1816); Interfacial Tension (ASTM D971); Power Factor 25Deg C (ASTM D924); Power Factor 100 Deg C (ASTM D924); Specific Gravity (ASTM D1298); Neut. No (ASTM D974)410EA20EA0EA$ - 0
40021Multi part screen/test (69kV and lower) one test that screens for the following: Color/Visual (ASTM D1500/D1524); Water/RS (ASTMD1533); Dielectric (ASTM D1816); Interfacial Tension (ASTM D971); Power Factor 25Deg C (ASTM D924); Power Factor 100 Deg C (ASTM D924); Specific Gravity (ASTM D1298); Neut. No (ASTM D974)50EA0EA0EA$ - 0
40022Viscosity - ASTM D4450EA0EA0EA$ - 0
40023Oxidation inhibitor in Natural Esters (FR3 Insulating Fluid) - ASTM D‐47680EA0EA0EA$ - 0
OPTION YEAR FOUR TOTAL$ - 0

TOTAL ESTIMATED CONTRACT VALUE $ - 0