SATPC0036174 Tab 04 attachment.pdf
PDF 304 KB Posted
- Attached to
- Service Contract for Deionized Water System Federal contract opportunity
- Solicitation number
- 80NSSC24879320Q
About this file
This document is a standard guide for ultra pure water used in the electronics and semiconductor industry. It covers six types of electronic grade water, ranging from Type E-1 water for devices with 0.5-1.0 mm line widths to Type E-4 water for electroplating applications. The guide provides detailed requirements for each water type, including limits on parameters such as resistivity, endotoxins, total organic carbon, dissolved oxygen, particles, bacteria, and ion/metal concentrations. It also describes the key water purification processes, including pretreatment, desalination, organic/biological removal, and particulate removal. The guide specifies sampling, testing, and system operation requirements to maintain the necessary water purity.
The related federal contract opportunity is for a service contract to provide a deionized water system. The solicitation is being issued by the National Aeronautics and Space Administration (NASA) Shared Services Center. The contract will require the contractor to design, install, and maintain a deionized water system to support NASA operations. No other details about the specific requirements, timeline, or anticipated value of the contract are provided in the given information.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| SATPC0036174 Tab 04 Questions and answers.pdf | ||
| SATPC0036174 Tab 10 Open Market RFQ.pdf | ||
| SATPC0036174 Tab 04 4 Spec sheet.pdf | ||
| SATPC0036174 Tab 10 Open Market RFQ.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Designation: D 5127 – 99
Standard Guide for Ultra Pure Water Used in the Electronics and Semiconductor Industry1
This standard is issued under the fixed designation D 5127; the number immediately following the designation indicates the year of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
1. Scope
1.1 This guide provides recommendations for water quality
related to current electronics and semiconductor industry requirements.
1.2 Water is used for washing and rinsing of semiconductor
components during manufacture. It is also used for cleaning and etching operations, making steam for oxidation of silicon surfaces, photomask preparation and luminescent material deposition. Other applications are in the development and fabrication of solid state, thin film, communication lasers, light emitting diodes, photo-detectors, printed circuits, memory, vacuum tube, or electrolytic devices.
1.3 This guide also provides recommendations for ultra pure
water quality related to industry requirements for production of devices having line widths from 5 to 0.18 μm.
1.4 This standard does not purport to address all of the
safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.
2. Referenced Documents
2.1 ASTM Standards:
D 1129 Terminology Relating to Water2 D 1193 Specification for Reagent Water2 D 1976 Test Method for Elements in Water by Inductively- Coupled Argon Plasma Atomic Emission Spectroscopy
(ICP-AES)2
D 2791 Test Method for Continuous Determination of So-dium in Water2 D 3919 Practice for Measuring Trace Elements in Water by Graphite Furnace Atomic Absorption Spectrophotometry2 D 4191 Test Method for Sodium in Water by Atomic Absorption Spectrophotometry2 D 4192 Test Method for Potassium in Water by Atomic Absorption Spectrophotometry2 D 4327 Test Method for Anions by Chemically Suppressed Ion Chromatography2
D 4453 Practice for Handling of Ultra Pure Water Samples2 D 4517 Test Method for Low-Level Total Silica in High- Purity Water by Flameless Atomic Absorption Spectros-copy (GFAAS)3 D 4779 Test Method for Total, Organic or Inorganic Carbon in High-Purity Water by Ultraviolet (UV) or Both, or by High Temperature Combustion Followed by Gas Phase NDIR or Electrolytic Conductivity3 D 5173 Test Method for On-Line Monitoring of Carbon Compounds in Water by Chemical Oxidation, by UV Light Oxidation, by Both, or by High Temperature Combustion Followed by Gas Phase NDIR or Electrolytic Conductiv-ity2 D 5391 Test Method for Electrical Conductivity and Resis-tivity of a Flowing High Purity Water Sample2 D 5462 Test Method for On-Line Measurement of Dis-solved Oxygen in Water2 D 5542 Test Methods for TraceAnions in High Purity Water by Ion Chromatography2 D 5544 Test Method for On-Line Measurement of Residue after Evaporation of High-Purity Water2 D 5673 Test Method for Elements in Water by Inductively- Coupled Argon Plasma Mass Spectrometry (ICP-MS)2 D 5996 Test Method for Measuring Anionic Contaminants in High-Purity Water by On-Line Ion Chromatography2 D 5997 Test Method for On-Line Monitoring of Total Car-bon, Inorganic Carbon, in Water by Ultraviolet, Persulfate Oxidation, and Membrane Conductivity Detection2 F 1094 Test Methods for Microbiological Monitoring of Water Used for Processing Electron and Microelectronic Devices by Direct-Pressure Tap Sampling Valve and by the Pre-Sterilized Plastic Bag Method4
3. Terminology
3.1 Definitions— For definitions of terms used in this guide
refer to Terminology D 1129.
3.2 Definitions of Terms Specific to This Standard:
3.2.1 endotoxins, n—substances or by-products usually pro-duced by gram negative microorganisms that give a positive test for pyrogens, determined in accordance with the limulus lysate test (9.2).1 This guide is under the jurisdiction of ASTM Committee D-19 on Water and is the direct responsibility of Subcommittee D19.02 on General Specifications, Technical Resources, and Statistical Methods.
Current edition approved June 10, 1999. Published September 1999. Originally published as D 5127 – 90. Last previous edition D 5127 – 98.
2 Annual Book of ASTM Standards, Vol 11.01.
3 Annual Book of ASTM Standards, Vol 11.02.
4 Annual Book of ASTM Standards, Vol 10.04.
Copyright © ASTM, 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959, United States.
3.2.2 total bacterial counts, n—total number of viable microorganisms present in the named sample, excluding anaerobic organisms, determined in accordance with Test Methods F 1094.
3.2.3 total organic carbon (TOC), n—carbon measured after inorganic carbon response has been eliminated by one of the prescribed ASTM test methods (such as elimination in accordance with Test Method D 4779).
3.2.4 water, n—water prepared in accordance with Specifi-cation D 1193, reagent grade Type I.
4. Significance and Use
4.1 This guide recommends the water quality required for
the electronic and microelectronic industry. High purity water is required to prevent contamination of products during manu-facture, which would otherwise result in an unacceptable, low yield of electronic devices.
4.2 The range of water purity is defined in accordance with
the manufacturing process. The types of ultra pure water are defined with respect to device line width.
4.3 The limits on the impurities are related to current
contamination specifications and to available analytical meth-ods performed in a suitable, clean laboratory or using on-line methods. On-line and off-line methods are used in accordance with current industry practice. Concentration of the sample may be required to measure the impurities at the levels indicated in Table 1.
5. Classification
5.1 Six types of electronic grade water are described in this guide.
5.1.1 Type E-1—This water is classified as microelectronic
water to be used in the production of devices having line widths between 0.5 and 1.0 μm.
5.1.2 Type E-1.1—This water is classified as microelec-
tronic water to be used in the production of devices having line widths between 0.25 and 0.5 μm.
TABLE 1 Requirements for Water Used in the Electronics and Semiconductor Industry Parameter Type E-1 Type E-1.1 Type E-1.2 Type E-2 Type E-3 Type E-4
Linewidth (microns) 1.0–0.5 0.5–0.25 0.25–0.18 5.0–1.0 > 5.0 —
Resistivity, 25°C 18.2 18.2 18.2 17.5 12 0.5 Endotoxin unit (EU/mL) 0.03 0.03 0.03 0.25 — — TOC (μg/L) 5 2 1 50 300 1000 Dissolved oxygen (μg/L) 1 1 1 — — — Residue after evaporation (μg/L) 1 0.5 0.1 — — — SEM particles/L (micron range) 0.1–0.2 1000 1000 200 — — — 0.2–0.5 500 500 100 3000 — — 0.5–1 50 50 1 — 10 000 — 10 — — — — — 100 000
On-line particles/L (micron range) 0.05–0.1 500 500 100 — — — 0.1–0.2 300 300 50 — — — 0.2–0.3 50 50 20 — — — 0.3–0.5 20 20 10 — — — > 0.5 4 4 1 — — — Bacteria/100 mL 100 mL Sample 1 1 1 — — — 1 L Sample 1 1 0.1 10 10 000 100 000
Silica – total (μg/L) 3 0.5 0.5 10 50 1000 Silica – dissolved (μg/L) 1 0.1 0.05 — — — Ions and metals (μg/L) Ammonium 0.1 0.10 0.05 — — — Bromide 0.1 0.05 0.02 — — — Chloride 0.1 0.05 0.02 1 10 1000 Fluoride 0.1 0.05 0.03 — — — Nitrate 0.1 0.05 0.02 1 5 500 Nitrite 0.1 0.05 0.02 — — — Phosphate 0.1 0.05 0.02 1 5 500 Sulfate 0.1 0.05 0.02 1 5 500 Aluminum 0.05 0.02 0.005 — — — Barium 0.05 0.02 0.001 — — — Boron 0.05 0.02 0.005 — — — Calcium 0.05 0.02 0.002 — — — Chromium 0.05 0.02 0.002 — — — Copper 0.05 0.02 0.002 1 2 500 Iron 0.05 0.02 0.002 — — — Lead 0.05 0.02 0.005 — — — Lithium 0.05 0.02 0.003 — — — Magnesium 0.05 0.02 0.002 — — — Manganese 0.05 0.02 0.002 — — — Nickel 0.05 0.02 0.002 1 2 500 Potassium 0.05 0.02 0.005 2 5 500 Sodium 0.05 0.02 0.005 1 5 1000 Strontium 0.05 0.02 0.001 — — — Zinc 0.05 0.02 0.002 1 5 500
D 5127
5.1.3 Type E-1.2—This water is classified as microelec-
tronic water to be used in the production of devices having line widths between 0.18 and 0.25 μm. It is the water of ultimate practical purity produced in large volumes and is intended for the most critical uses.
5.1.4 Type E-2—This water is classified as microelectronic
water to be used in the production of devices that have dimensions between 1 and 5 μm.
5.1.5 Type E-3—This grade of water is classified as macro-
electronic water to be used in the production of devices having dimensions larger than 5 μm. This grade may be used to produce larger components and some small components not affected by trace amounts of impurities.
5.1.6 Type E-4—This may be classified as electroplating
water to be used in the preparation of plating solutions, the production of certain electronic grade chemicals, and other applications where the water being used is in constant contact with the atmosphere because of tank storage. This water purity is based upon the fact that the water may have had a significantly higher purity, but that it becomes contaminated because of tank storage and handling.
5.2 Components of the water system for producing elec-
tronic grade water shall be grouped into five general process sections for the purpose of simplifying the organization of the components of the systems. These processes are described in 5.2.1-5.2.5.
5.2.1 Pretreatment—The processes in this category include
the addition of various types of coagulants, precipitating agents, clarifiers, sedimentation tanks, particulate filtration systems, including sand filters, disposable filter elements, ultrafilter membranes, and other particle removing systems.
Adsorbent or entrapment beds may include greensand, acti-vated carbon, and various synthetic materials specific for certain organic and inorganic impurities.
5.2.2 Desalination—This process is fundamental to the
production of ultrapure water of all grades and may include more than one of the processes of ion exchange, distillation, reverse osmosis, electrodialysis, or continuous electrodeioniza-tion or all of the above. The size of the system governs the choice of the combination of desalination processes; for example the use of distillation in a laboratory that would not be practical in a large production plant. Various configurations of the different processes should be considered, including two-bed and mixed-bed demineralization, multi-stage reverse os-mosis employing various types of membranes, and electrodi-alysis that might employ periodic polarity reversal techniques as well as the use of resins placed between the cation and anion membranes.
5.2.3 Organic and Biological Removal Systems—Removal
of biological and organic contaminants is an important adjunct of any system used to prepare ultra pure water. Dissolved organic compounds can accumulate in the system during the process as well as being present in the original water. Methods of minimizing biological contamination include the addition of active chlorine (sodium hypochlorite), hydrogen peroxide, and ozone. Ultraviolet irradiation at 254 nm significantly reduces the growth of organisms. Ultraviolet irradiation at 185 nm produces traces of ozone that break down organic compounds to carbon dioxide. Adsorptive beds such as strong base anion resins as well as mixed resin beds may also be effective in removing biological contaminants. Membrane filters including reverse osmosis and ultrafilters may also remove biological impurities as well as organic molecules. Synthetic adsorbent columns ranging from porous resins to activated carbon may be effective in removing organics.
5.2.4 Particulate Removal—Particulate removal in the pro-
duction of ultra pure water is differentiated from pretreatment to remove gross suspended substances. Particles of all types, biological, organic, or inorganic, significantly interfere with the production of electronic components. Processes used to re-move particulate matter generally consist of the use of a microporous membrane structure of flat, cylindrical, or pleated configuration. In the case of ultrafilters and reverse osmosis units, they are of hollow fiber, tubular, or spiral wound. The choice of the particular membrane depends upon the pore size, characteristics of that membrane, and the size of particle to be removed. As a general rule, particles of a size larger than 10 % of the minimum dimension of the device being produced should be removed. The measurement of these particles be-comes difficult at best and is generally dictated by the quality and pore size of the membrane used as the final filter.
5.2.5 Storage and Distribution System—This guide for the
storage of electronic grade water during production is very important because impurities are added to the water in propor-tion to the solubility, area of contact, and time of contact between the water and materials of containment. Because it is important to minimize the contact with the materials of containment of storage, the volume of storage should also be minimized. Particular emphasis must be placed upon the atmosphere above the water that may contaminate the water with biological, organic, inorganic, and particulate impurities.
The storage of E-1, E-1.1, E-1.2, E-2, and E-3 waters is impossible (if expecting to maintain purity); therefore, all storage should be before the final polishing, tertiary section.
5.2.5.1 The distribution systems also present a large area of contact between the water and pipe or tubing and, therefore, must be of a pure insoluble substance. Once again, the degree of contamination depends upon the solubility of the materials of contact as well as the time of contact. For that reason and because biological impurities tend to accumulate in stagnant water, the flow of water through the distribution system must be maintained on a continuous 24 hr basis. Contaminants probably dissolve in the water at a constant rate; therefore an increase in the velocity through the pipe will give an apparent reduction in the contamination. However the flow rate, particu-larly through large pipes above 50 mm diameter that have a small surface to volume ratio, need not exceed 25 cm/s.
5.2.5.2 Plastic systems should be installed with care without the use of oils of any kind. Generally, cleaning prior to use is best accomplished by rinsing for several days with pure water.
If the system has been idle for a period of time or was not clean when installed, a pre-rinse of nonionic detergent and 200 mg/L sodium hypochlorite might be required. The distribution out-lets must also be of noncontaminating design and materials, with particular care given to minimize the possibility of back contamination of the system from the faucet or valve outlet.
5.3 Component Sections:
5.3.1 Primary Section—This section of the water system
performing the primary purification of the input water should utilize one or more of the pretreatment and desalination processes noted in 5.2. The water produced in the primary section, should have a purity equivalent to Type E-4 and may or may not be stored prior to use or additional purification.
5.3.2 Secondary Purification Section—This section of the
water system should be dedicated to upgrading the effluent of the primary section to the purity level of Type E-3 that will include organic and biological removal as well as additional desalination processes as necessary. Particulate removal may also be incorporated into this section of the purification train depending upon the processes used in the primary section. The water from the secondary purification section may be stored for use in a protected tank system or used directly from the purification train if a degradation of the resistance is to be avoided.
5.3.3 Tertiary Section—This section of the water system is
dedicated to the removal of traces of ionized impurities, organics, and biological and particulate contaminants that will increase the purity to the requirements of Type E-1, E-1.1, E-1.2, or Type E-2. This section may include additional mixed bed ion exchange (regenerative or cartridge systems), ultravio-let light (the radiation of both 254 and 185 nm), and finally filtration, using the components described in 5.2.4. The water from this section of the system should be used without storage and should be recirculated continuously.
6. Requirements
6.1 Electronic grade water when referenced to this guide
shall conform to the recommendations in Table 1. Additional recommendations, including the modification or elimination of certain test procedures, may be included as part of this guide by agreement between the parties concerned.
7. Reagents
7.1 Purity of Reagents:
7.1.1 Types E-1, E-2, E-3, and E-4—Reagent grade chemi-
cals shall be used in all tests.
7.1.2 Types E-1.1 and E-1.2—Ultra pure chemicals shall be
used in all tests. Other grades may be used, provided it is first ascertained that the reagent is of sufficiently high purity to permit its use without lessening the accuracy of the determi-nation.
7.1.3 Unless otherwise indicated, all reagents shall conform
to the specification of the Committee onAnalytical Reagents of the American Chemical Society5, where such specifications are available. Other grades may be used, provided it is first ascertained that the reagent is of sufficiently high purity to permit its use without lessening the accuracy of the determi-nation.
7.2 Purity of Water:
7.2.1 Types E-1, E-2, E-3, and E-4—References to water
shall be understood to mean Type I reagent grade water in accordance with Specification D 1193.
7.2.2 Types E-1.1 and E-1.2—Water equivalent to or better
than E-1.2 is required.
8. Sampling
8.1 The test methods specified in Section 9 assume that
great care and skill are required to obtain water samples to be tested. It is assumed that container and airborne contamination is minimized and operators should note possible sources of contamination due to the sampling procedure. It is recom-mended that the samples be handled as noted in Practice D 4453.
8.2 Extreme care must be exercised in handling samples for
analyses. Pre-cleaned polystyrene flasks and high quality HDPE are recommended as sample containers. PFA or TFE-fluorocarbon will leach fluoride. Borosilicate glassware leach ions at low microgram per litre levels. The major contaminants from borosilicate glass are sodium (Na), potassium (K), boron (B), and silica (SiO2).
9. Test Methods
9.1 Electrical Resistivity—Test Method D 5391, Resistivity
(conductivity) is measured off- or on-line depending on the application.
NOTE 1—18.25 MegOhm-centimeter is the theoretical limit for pure water at 25°C.
9.2 Endotoxins—Limulus Lysate Test5
9.3 TOC—Test Methods D 5173 and D 5997, involve on-
line oxidation of organic materials and measurements of the carbon dioxide produced by conductivity or infrared photom-etry.
9.4 Dissolved oxygen should be measured on-line when
required by Test Method D 5462.
9.5 Residue after evaporation uses Test Method D 5544.
9.6 Particulate Matter (particles/L)—Scanning electron mi-
croscopy (SEM) with an elemental analyzer accessory is useful for troubleshooting. On-line methods of data acquisition using laser technology are recommended for trend analysis.
9.7 Bacteria (number of bacteria/100 mL)—Test Methods
F 1094, Cultures are run in triplicate using acceptable filters and sample sizes of 100 or 1000 mL. Total count of the media after incubation at 28°C for 48 to 72 hours depending on the specifications. Epi-fluorescence microscopy has also been used to measure and identify bacteria.
9.8 Silica—Total silica (μg/L) GFAAS, ICP-AES, and
ICP-MS are suitable techniques, Test Method D 4517, D 1976, or D 5673. Dissolved silica (μg/L as SiO 2) utilizes heteropoly blue photometry or ion chromatography for the lowest levels.
9.9 Ionic Concentrations (μg/L)—Many anions and cations
may be determined by using ion chromatography either off-line by Test Method D 4327 or D 5542, or preferably on-line by Test Method 5996–96. Metals may be determined using ICP-AES (Test Method D 1976) or ICP-MS (Test Method D 5673) using suitable ICP conditions in accordance with the analytical requirement.
5 Reagent Chemicals, American Chemical Society Specifications, American Chemical Society, Washington, DC. For suggestions on the testing of reagents not listed by the American Chemical Society, see Analar Standards for Laboratory Chemicals, BDH Ltd., Poole, Dorset, U.K., and the United States Pharmacopeia and National Formulary, U.S. Pharmaceutical Convention, Inc. (USPC), Rockville, MD.
9.9.1 Copper—Practice D 3919.
9.9.2 Nickel—Practice D 3919.
9.9.3 Potassium—Test Method D 4192.
9.9.4 Sodium—Test Methods D 2791 and D 4191.
9.9.5 Zinc—Practice D 3919.
9.10 Where a test covering the particular impurity or con-
taminant is not sensitive enough to reliably measure the impurity at the level specified in Table 1, a suitable nonrefer-enced test shall be made by agreement between the concerned parties.
9.11 The sample may require concentration in order to
measure the impurities at the levels indicated in Table 1.
10. Systems Operations
10.1 The size of the components of the primary, secondary, and tertiary sections of the water system is influenced by the ability of the user to recirculate all or some portion of the water after it has been used in a cleaning or component rinse operation. The term recirculation refers to the process of piping used water back to a point in the system where it may be purified or combined with water of approximately equal quality. From this point it is processed through the secondary section, and if necessary through portions of the primary section, followed by the tertiary section, and reused.
10.1.1 Water recovered from processes that impart contami-
nants to the water in large quantities, such as nonionic surfactants that may be difficult to remove because of the particular configuration of the system, should not be recircu-lated.
10.2 The quality of the effluent water depends upon the age, type, and method of regeneration of the ion exchange resins.
Likewise, the flow rate through the ion exchange resin bed will affect the resistivity of the effluent water. The resin manufac-turer’s instructions relating to flow rate and regeneration procedure should be followed.
10.3 The use of microporous, reverse osmosis, or ultrafilter
membranes as well as the use of plastic piping in the system may add a small amount of organic contamination to the water produced. Water users concerned with the most critical elec-tronic device applications should be aware of this contamina-tion and, where necessary, measure or monitor the level of organic contamination by means of a total organic carbon analysis, or other applicable analytical procedure.
10.3.1 Certain membranes contain small quantities of
soluble impurities as a result of the manufacturing process.
Care must be taken to avoid the use of the initial effluent from such membranes when membrane changes are made.
10.3.2 The periodic back flushing and cleaning required
with the use of some types of ultra-filters or reverse-osmosis (RO) units imparts contaminants to the filter that the user must take care to flush from the membrane system before placing the system back on-line.
10.3.2.1 In certain applications involving the processing of
sodium-sensitive, solid-state electronic devices, users may prefer to fast flush or back flush with a hydrogen peroxide or ozone solution to reduce the rinse time required when using the generally recommended sodium hypochlorite flush solution.
The user should check with the manufacturer to make certain that the membranes resist the chemicals used and tolerate the type of flushing.
10.4 Because atmospheric gases and airborne impurities
rapidly re-contaminate exposed water, in-line electrodes must be employed for determining the electrical resistivity of electronic grade waters of Types E-1, E-1.1, E-1.2, E-2, E-3, or E-4. Most pH measuring devices introduce impurities from electrodes to Types E-1, E-1.1 E-1.2, E-2, and E-3 waters that reduces the purity of the waters, thus making the pH measure-ment invalid.
11. Keywords
11.1 electronic; microelectronics; semiconductor; ultra pure water
The American Society for Testing and Materials takes no position respecting the validity of any patent rights asserted in connection with any item mentioned in this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the risk of infringement of such rights, are entirely their own responsibility.
This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years and if not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standards and should be addressed to ASTM Headquarters. Your comments will receive careful consideration at a meeting of the responsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you should make your views known to the ASTM Committee on Standards, 100 Barr Harbor Drive, West Conshohocken, PA 19428.
This standard is copyrighted by ASTM, 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959, United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the above address or at 610-832-9585 (phone), 610-832-9555 (fax), or service@astm.org (e-mail); or through the ASTM website (http://www.astm.org).