80 gallon steam kettle specs.pdf

PDF 427 KB Posted

Attached to
IDOC PNK 80 GAL GAS STEAM KETTLE bjl
Solicitation number
26-426DOC-PINCK-B-49625
Issued by
Piatt County, Illinois

About this file

This document is a product specification sheet for Crown Middleby Gas Steam Stationary Kettles, specifically the GL-80E and GL-100E models. The specifications detail a commercial-grade stationary kettle designed for professional kitchen environments, with an 80-gallon (GL-80E) or 100-gallon (GL-100E) capacity. The kettles are gas-fired, ASME Code stamped, and NSF approved, featuring a type 304 stainless steel exterior, type 316 stainless steel interior, and a 2/3 steam jacketed design. Standard features include electronic ignition, direct immersion thermostat, water sight glass, cooking light, pressure gauge, low water indicator light, low water cut-off, pressure relief valve, and pressure switch.

The kettles are configured for natural gas or L.P. gas operation, with 115 VAC, 1-phase electrical requirements and temperature ranges between 165°F to 265°F. Each model has specific technical specifications, including 150,000 BTU/HR output, 44.0 kW/HR, and varying shipping weights (GL-80E at 950 lbs, GL-100E at 1100 lbs). Optional accessories are available at additional cost, such as correctional packages, pantry faucets, kettle fillers, and various measurement and straining accessories. The product is explicitly marked as intended for commercial use only and requires installation on non-combustible floors with specific gas supply and electrical connection guidelines.

View the file

Other files

File Type Posted
PNK Steam Kettle B-49625 BOA.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Crown (Middleby) Model GL‐80E Dimensions: 44.63(h) x 41.63(w) x 60.13(d) Stationary Kettle, gas, 80 gallon capacity, 2/3 jacket, thermostatic control, electronic ignition, direct immersion thermostat, water sight glass, cooking light, pressure gauge & low water indicator light, low water cut off, pressure relief valve, pressure switch, 2" draw‐off, includes: perforated strainer, spring assisted hinged cover & faucet bracket, 316 stainless steel interior liner, 304 stainless steel exterior, tri‐leg, 150,000 BTU, CSA‐Star, CSA‐Flame, NSF

Domestic Shipping, inside of North America Standard one year limited, 10 year hemispheric bottom warranty Additional one year warranty (NET) Natural Gas 120v/50/60/1‐ph, cord and plug, standard Model TPS‐2 Perforated Strainer, for 2" draw‐offs, standard Model KBUK‐1 Kettle Cleaning & Utensil Kit, includes (1) 36" cleaning brush & scraping paddle, draw‐off valve brush, hand held scrub brush, stainless steel 36" whip & 24 ounce ladle Stainless steel hinged cover over control panel with locking provisions Correctional screws & tack welds (where applicable) Dormont Model RDC48 Dormont Restraining Device for 48" Connectors

ELECTRICAL

VOLTS CYCLE PHASE CONN AFF NEMA AMPS KW HP MCA MOCP

1 120 60 1 Cord & Plug

GAS STEAM

SIZE MBTU KW CONN INLET SIZE RETURN SIZE LB/HR PSIG (MIN) PSIG (MAX)

1 3/4" 150.0 1

WATER WASTE

HOT

SIZE

HOT

AFF

HOT

GPH

COLD

SIZE

COLD

AFF

FILTERED

SIZE

FILTERED

AFF

CONDENSER

INLET SIZE

CONDENSER

OUTLET SIZE

INDIRECT

SIZE

DIRECT

SIZE

1 1

PLUMBING 1 REMARKS

(Connections for optional faucet)

70 Oakdale Road, Toronto ON, Canada M3N IV9

(919) 762-1000 www.crownsteamgroup.com

Approval Notes: ________________________________

G L80-100

Job: Item#

Printed in USA Date:____________Form GL80-100 Rev 4 (November/2022)

STANDARD CONSTRUCTION SPECIFICATIONS

Gas Steam Kettle Stationary

Shall be a Crown model GL-80E or GL-100E, gas fired, self-contained, fully insulated steam jacketed kettle, ASME Code stamped, National Board Registered, AGA and CGA design certified, NSF approved.

The unit comes standard with a spring assisted cover.

The kettle shall be constructed with an exterior of type 304 stainless steel, #4 sanitary finish and four 6” stainless steel adjustable legs.

The interior kettle liner shall be a one piece welded construction made with type 316 stainless steel with #4 sanitary finish, 2/3 jacketed and shall be furnished with a 2” tangent draw off valve with strainer as standard.

The recessed control panel is located on the front side of the unit in full view of the operator and is easy to use.

Standard controls include electronic ignition, direct immersion thermostat, water sight glass, cooking light, pressure gauge and low water indicator light.

Safety features shall include a low water cut off, pressure relief valve, and pressure switch.

A double wall kettle interior shall form a steam jacket around the lower 2/3 of the kettle. The bottom of the kettle shall be of hemispherical design for superior heat circulation.

Convenience features shall include 2” (50 mm) sanitary draw-off valve with a heat resistant handle.

Faucet bracket included.

GL-80E

GL-100E

OPERATION SHALL BE BY:

Natural Gas

L.P. Gas

For operation on 115 VAC, 1 phase 50/60 Hz, A.S.M.E.

code stamped for operation up to 35 psi (241 kPa).

The steam kettle temperature ranges shall be between 165°F to 265°F (74°C to 130°C).

220-240 VAC operation (specify voltage) (GKVS-1)

3” (76 mm) draw-off valve with perforated strainer (TVS-3)

Etched gallon markings (GM-)

Etched liter markings (LM-)

OPTIONS & ACCESSORIES AT ADDITIONAL COST

Correctional Package

Single pantry faucet with swing spout, SF-12

Double pantry faucet with swing spout, DF-12

Single pantry kettle filler (SP-KF-GK)

Double pantry kettle filler (DP-KF-GK)

Stainless steel tri basket, (TBA-)

Solid disc for draw-off valve (TSS-)

Graduated measuring strip (CMS-)

Strainer hook (SH-)

Draw-off valve hose kit (DVHK-)

Christopher Smith Highlight

Christopher Smith Highlight

Christopher Smith Highlight

70 Oakdale Road, Toronto ON, Canada M3N IV9

(919) up.com

Models:

G L80-100

Model Capacity

GL-80E 80 Gallon 303 Liter

GL-100E 100 Gallon 379 Liter

Printed in USA Date:____________Form GL80-100 Rev 4 (November/2022)

INTENDED FOR COMMERCIAL USE ONLY.

NOT FOR HOUSEHOLD USE.

SPECIFICATIONS

GAS CHARACTERISTICS

* For use on non-combustible floors only.

KS

LG

-8

KS

LG

-1

KS

LG

-8

KS

LG

-1

00KS

LG

-8

KS

LG

-1

SERVICE CONNECTIONS

– Supply gas through 3/4” pipe. A gas shut-off valve must be installed in supply piping convenient and adjacent to appliance

– Unless other wise specified, Field Wire Electrical Connection to be 120 Volts, 60 Hertz, single phase with grounding wire. Unit furnished with 6’ cord and 3 prong plug. Total maximum amps 2.0.

Model Shipping Weight Minimum Clearance *

GL-80E 950 lbs. [430 kg] Side Back

6” [152 mm] 2” [51 mm]

GL-100E 1100 lbs. [498 kg]

Model Gas Supply

BTU/HR. kW/HR. Supply Pipe Pressure (W.C.)

GL-80E 150,000 44.0 Natural 6”-14” (152-355 mm)

Propane 11”-14” (279-355 mm)GL-100E 150,000 44.0

GL-80E GL-100E