8-Highview Linda Lou Apts. Architectural Sealed Set.pdf
PDF 5 MB Posted
- Solicitation number
- 2602-5657
- Issued by
- Bexar County, Texas
About this file
This is an Architectural Sealed Set of construction documents prepared by Durand-Hollis Rupe Architects for Opportunity Home San Antonio (formerly San Antonio Housing Authority) for roofing and window replacement at two residential properties: Highview Apartments located at 1351 Rigsby Avenue, San Antonio, Texas 78210, and Linda Lou Apartments located at 4603 S Hackberry Street, San Antonio, Texas 78223. The project scope includes complete roof replacement and window retrofitting across multiple building types at Highview Apartments (33 buildings categorized into three building types) and two buildings at Linda Lou Apartments (Buildings 102 and 124). All work must comply with the International Building Code (2024), International Existing Building Code (2024), International Fire Code (2024), International Mechanical Code (2024), International Plumbing Code (2024), National Electrical Code (2024), International Energy Conservation Code (2021), and City of San Antonio Codes with Amendments. The construction documents specify non-destructive window replacement methods using flush flange replacement windows and re-roofing with asphalt shingles at Highview Apartments and standing seam metal roofing at Linda Lou Apartments, with all new roofing installed over a 45-mil peel and stick membrane. Contractors must field-verify all existing conditions and dimensions prior to bidding, maintain buildings watertight throughout the renovation, and comply with all applicable codes and regulations.
Work activities are limited to 7:00 AM with limited noise until 8:00 AM, then full work operations until 5:00 PM with cleanup extending to 6:00 PM, Monday through Friday, with Saturday work not preferred and requiring owner consent and prior approval. Contractors are responsible for all fees and permits, discovery and proper handling of hazardous materials including asbestos and lead-based paint, protection of existing site improvements, daily cleanup and debris removal, and ensuring no construction materials or equipment remain on-site overnight except for a lockable porta potty. An Alternate #1 is available for contractors to provide pricing for the introduction of cellulose insulation to all existing attic spaces over occupied areas to achieve R-38 thermal performance in compliance with the International Energy Conservation Code 2021. The construction documents note that the existing buildings contain hazardous materials including chrysotile asbestos in sheetrock, ceiling gypsum board, floor tile and mastic, and lead-based paint on interior walls, ceilings, doors, window sills, trim, and baseboards, requiring contractors to exercise proper OSHA procedures for personnel protection and coordinate with the owner prior to any required disturbances.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
HIGHVIEW APARTMENTS PROJECT SITE MAP LINDA LOU APARTMENTS PROJECT SITE MAP
INTERNATIONAL BUILDING CODE (2024)
INTERNATIONAL EXISTING BUILDING
CODE (2024)
INTERNATIONAL FIRE CODE (2024)
INTERNATIONAL MECHANICAL CODE (2024)
APPLICABLE CODES
CITY OF SAN ANTONIO CODES WITH AMMENDMENTS
INTERNATIONAL MECHANICAL CODE (2024)
INTERNATIONAL PLUMBING CODE (2024)
NATIONAL ELECTRICAL CODE (2024)
INTERNATIONAL ENERGY CONSERVATION
CODE (2021)
HIGHVIEW APARTMENTS
VICINITY MAPS
PROJECT
LOCATION
HIGHVIEW APARTMENTS
VICINITY MAPS
PROJECT
LOCATION
LINDA LOU APARTMENTS
PRESIDENT & CEO
MICHAEL REYES
HECTOR MARTINEZ DIRECTOR OF CONSTRUCTION SERVICES & SUSTAINABILITY
PROJECT CONTACTS
EDWARD RENDON PROJECT MANAGER
GABRIEL LOPEZ
GILBERT CASILLAS
BARBARA ANKAMAH BURFORD
DALIA FLORES CONTRERAS
ESTRELLITA GARCIA-DIAZ
JANET GARCIA
LEILAH POWELL
CHAIR
VICE CHAIR
COMMISSIONER
BOARD COMMISSIONERS
COMMISSIONER
COMMISSIONER
COMMISSIONER
COMMISSIONER
INTERNATIONAL ENERGY CONSERVATION CODE 2021
BUILDING ENVELOPE REVIEW, EXISTING BUILDINGS:
DESCRIPTION OF WORK: ROOF REPAIRS AND WINDOW REPLACEMENT OF EXISTING BUILDINGS WITH NO CHANGES TO USE OR OCCUPANCY:
IECC C501.4 NEW REPLACEMENT MATERIALS SHALL BE AS PERMITTED FOR NEW CONSTRUCTION EXCEPT AS NOTED.
IECC 503.1 ALTERATIONS TO AN EXISTING BUILDING SHALL CONFORM TO THE PROVISIONS OF THIS CODE AS THOSE PROVISIONS RELATE TO NEW CONSTRUCTION.
EXCEPTION #3: ROOF RECOVER EXCEPTION #4: ROOF REPLACEMENT WHERE ROOF ASSEMBLY INSULATION IS INTERGRAL TO OR LOCATED BELOW THE STRUCTURAL DECK.
IECC 503.2.2.1 WHERE SOME OR ALL EXISTING FENESTRATION IS REPLACED WITH NEW PRODUCT THEN THE REPLACEMENT FENESTRATION UNIT SHALL MEET THE APPLICABLE
REQUIRMENTS FOR U-FACTOR AND SHGC IN TABLE C402.5
IECC C402.5 U-FACTOR, CLIMATE ZONE 2:
FIXED FENESTRATION: U-FACTOR 0.45
OPERABLE FENESTRATION: U-FACTOR 0.60 ACTUAL THERMAL TRANSMITTANCE: NFRC MAXIMUM WHOLE WINDOW U-FACTOR IS 0.30
SHGC, CLIMATE ZONE 2:
PROJECTION FACTOR LESS THAN 0.2: 0.25 FIXED, 0.23 OPERABLE ACTUAL MAXIMUM WHOLE WINDOW
SHGC OF 0.30
PROJECTION FACTOR GREATER THAN 0.2 BUT LESS THAN 0.5: 0.30 FIXED, 0.28 OPERABLE (HIGHVIEW BUILDINGS HAVE MINIMAL
PROJECTION
PROJECTION FACTOR GREATER THAN OR EQUAL TO 0.5: 0.40 FIXED, 0.37 OPERABLE LINDA LOU HAS SIGNIFICANT PROJECTION)
IECC 503.2.4 ABOVE GRADE WALL ALTERATIONS WHERE CAVITIES ARE EXPOSED SHALL BE INSULATED, HOWEVER, WE ARE USING A NON-DESTRUCTIVE WINDOW REPLACEMENT METHOD
WHICH WILL NOT EXPOSE THE WALL CAVITIES.
IECC 504.2 ITEM #2: ROOF REPAIRS ARE CONSIDERED REPAIRS
ITEM #3: AIR BARRIERS SHALL NOT BE REQUIRED FOR ROOF REPAIRS WHERE THE REPAIRS TO THE BUILDING DO NOT INCLUDE ALTERATIONS, RENOVATIONS, OR REPAIRS TO THE REMAINDER OF THE BUILDING THERMAL ENVELOPE. HOWEVER, AS BOTH THE SHINGLED REPAIRS AT HIGHVIEW AND THE METAL ROOFING AT LINDA LOU WILL BE SET OVER A 45 MIL. PEAL AND STICK MEMBRANE THE NEW ROOFING WILL EXCEED THE AIR BARRIER REQUIRMENTS FOR NEW CONSTRUCTION.
IECC 402.6.1.1 AIR BARRIER DESIGN COMPONENTS, WINDOW REPLACEMENT:
JOINT TREATMENT: ALL WINDOW REPLACEMENTS ARE NON-DESTRUCTIVE, LEAVING THE EXISTING WINDOW FRAMES ABANDONED IN THE WALL ASSEMBLY AND AS SUCH THERE IS NO DISTURBANCEO OF THE EXISTING AIR BARRIER OR PERIMETER JOINTS. AS REQUIRED BY ITEM #4 AND DETAILED IN SPECIFICATION APPENDIX “A” AAMA GUIDELINES, ALL NEW JOINTS AROUND OVERLAPPING FENESTRATION WILL BE SEALED AND ANY MINOR CAVITIES INSULATED.
ALTERNATE #1 ALTERNATE #1 INCLUDES THE INTRODUCTION OF CELLULOSE INSULATION TO ALL EXISTING ATTIC SPACES OVER
OCCUPIED AREAS TO A DEPTH REQUIRED TO ACHIEVE R-38.
SHEET INDEX
ARCHITECTURAL
A-001 COVER SHEET
A-010 HIGHVIEW APARTMENTS ARCHITECTURAL SITE PLAN
A100 HIGHVIEW APARTMENTS DEMOLITION PLANS
A101 HIGHVIEW APARTMENTS TYPICAL FLOOR PLANS
A-102 HIGHVIEW APARTMENTS BUILDING TYPE I - TYPICAL
A-103 HIGHVIEW APARTMENTS BUILDING TYPE II - TYPICAL
A-104 HIGHVIEW APARTMENTS BUILDING TYPE III - TYPICAL
A-105 HIGHVIEW APARTMENTS RE-ROOFING DETAILS
A-106 HIGHVIEW APARTMENTS WINDOW TYPES
A-107 HIGHVIEW APARTMENTS WINDOW REPLACEMENT DETAILS
A-200 LINDA LOU APARTMENTS ARCHITECTURAL SITE PLAN
A-200.1 LINDA LOU APARTMENTS DEMOLITION PLAN BUILDING 102
A-200.2 LINDA LOU APARTMENTS DEMOLITION PLAN BUILDING 124
A-201 LINDA LOU APARTMENTS BLDG. 102 ROOF & ELEVATIONS
A-202 LINDA LOU APARTMENTS BLDG. 124 ROOF & ELEVATIONS
A-203 LINDA LOU APARTMENTS BUILDING 102 FLOOR PLAN
A-204 LINDA LOU APARTMENTS BUILDING 124 FLOOR PLAN
A-205 LINDA LOU APARTMENTS WINDOW TYPES AND SCHEDULES
A-206 LINDA LOU APARTMENTS RE-ROOFING DETAILS
A-207 LINDA LOU APARTMENTS RE-ROOFING DETAILS
A -208 HIGHVIEW / LINDA LOU APARTMENTS ALTERNATE # 1 ADDITIONAL INSULATION
DURAND-HOLLIS RUPE
ARCHITECTS, INC.
14603 HUEBNER RD.
BUILDING 18
SAN ANTONIO, TEXAS 78230
PHONE: 210/308-0080
FAX: 210/697-3309
eMAIL: office@dhrarchitects.com
THIS DRAWING IS PROVIDED AS AN INSTRUMENT
OF SERVICE BY THE ARCHITECT AND IS INTENDED
FOR USE ON THIS PROJECT ONLY. THE DRAWING
REMAINS THE PROPERTY OF THE ARCHITECT AND
SHALL BE RETURNED TO HIM/HER UPON THE
COMPLETION OF THE CONSTRUCTION WORK.
PERSUANT TO THE ARCHITECTURAL WORKS
COPYRIGHT PROTECTION ACT OF 1990, ALL
DRAWINGS, SPECIFICATIONS, IDEAS AND
DESIGNS, INCLUDING THE OVERALL FORM,
ARRANGEMENT AND COMPOSITION OF SPACES
AND ELEMENTS APPEARING HEREIN, CONSTITUTES
THE COPYRIGHTED WORK OF THE ARCHITECT.
ANY REPRODUCTION, USE, OR DISCLOSURE OF
INFORMATION CONTAINED HEREIN WITHOUT
PRIOR WRITTEN CONSENT OF THE ARCHITECT IS
STRICTLY PROHIBITED.
© 2025
SHEET NO.:
ARCHITECT:
GABRIEL DURAND-HOLLIS, FAIA
LICENSE NUMBER: TX 10881
RO
O
FI
N G A N D W
IN
DO
W R
EP
LA
C
EM
EN
T
O
PP
O
RT
UN
ITY
H O M E
SA
N A N
TO
N
IO
HI
G
HV
IE
W A
PA
RT
M
EN
TS
L
IN
DA
L O U A
PA
RT
M
EN
TS
COVER SHEET
PROJECT No. : 25-005
ISSUE DATE: 12/11/25
DRAWN BY: DHR
REVIEWED BY: DHR
A001
R
IG
SB
Y A V E, S A N A N
TO
N
IO
, T X
S H A C
KB
ER
RY
S T, S A N A N
TO
N
IO
, T X
OPPORTUNITY HOME SAN ANTONIO
HIGHVIEW APARTMENTS & LINDA LOU APARTMENTS
1351 RIGSBY AVE, SAN ANTONIO, TX 78210
4603 S HACKBERRY ST, SAN ANTONIO, TX 78223
LINDA LOU APARTMENTS
ROOFING AND WINDOW REPLACEMENT REVISED ISSUE DATES
NO ISSUE DATE
TYPE I
TYPE I
TYPE I
TYPE I
TYPE I
TYPE I
TYPE I TYPE I
TYPE I
TYPE I
TYPE I
TYPE I
TYPE I
TYPE I
TYPE I
TYPE I
TYPE I TYPE I
TYPE III
TYPE III
TYPE II
TYPE II TYPE II TYPE II
TYPE II
TYPE II
TYPE II
TYPE II
TYPE II
TYPE IITYPE II
TYPE II
TYPE II
TYPE II
TYPE II
HALLIE AVE
H A
LL
IE
A
VE
HALLIE AVE
H A
LL
IE
A
VE
RIGSBY AVE
RIGSBY AVE RIGSBY AVE
RIGSBY AVE
RIGSBY AVE
H A
LL
IE
A
VE
FIRE HYDRANT
FIRE HYDRANT
EXISTING
POWER POLE
TO REMAIN EXISTING
POWER POLE
TO REMAIN
EXISTING
POWER POLE
TO REMAIN
EXISTING
POWER POLE
TO REMAIN
EXISTING
POWER POLE
TO REMAIN
EXISTING
POWER POLE
TO REMAIN
EXISTING
PUBLIC
SIDEWALK
FIRE LANE DO NOT BLOCK
FIRE LANE DO NOT BLOCK
REROOF AND
PROVIE WINDOW
REPLACEMENT
FOR ALL
BUILDINGS AND
STRUCTURES AT
HIGHVIEW
APARTMENTS.
8 9 10
15 16 17
GENERAL NOTES
1.
2.
CONSTRUCTION DOCUMENTS: THIS SET OF CONSTRUCTION DOCUMENTS IS PRESENTED TO INCLUDE DRAWINGS AND A SET OF SPECIFICATIONS ON 24" x 36" SHEETS. THIS SET OF CONSTRUCTION
DOCUMENTS INDICATES THE GENERAL DESIGN INTENT, AND MAY NOT DESCRIBE ALL WORK
REQUIRED FOR FULL PERFOMANCE AND COMPLETION. THE CONTRACTOR SHALL PROVIDE ALL
ITEMS REQUIRED FOR A COMPLETE AND OPERATIONAL PROJECT. ALL OF THE CONTRACT
DOCUMENTS (ARCHITECTURAL) ARE TO BE USED TOGETHER. THE GENERAL CONTRACTOR AND ALL
SUBCONTRACTORS ARE TO REVIEW COMPLETE SETS OF DOCUMENTS AND REPORT ANY
DISCREPANCIES TO THE ARCHITECT IMMEDIATELY. SHOULD ANY QUESTIONS ARISE PRIOR TO THE
BEGINNING OF CONSTRUCTION OR DURING CONSTRUCTION, THE CONTRACTOR SHALL
IMMEDIATELY NOTIFY THE ARCHITECT FOR REVIEW AND CLARIFICATION BEFORE PROCEEDING
WITH THAT PORTION OF THE WORK OR ANY PART RELATED THERETO.
WORK DESCRIBED ON THESE CONTRACT DOCUMENTS AND SPECIFICATIONS PERTAIN TO THE NEW
ROOF SYSTEM INSTALLATION & WINDOWS RETROFIT. MATERIALS ARE AS SCHEDULED OR NOTED.
3. EXISTING CONDITIONS: THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND
DIMENSIONS AT THE JOB SITE BEFORE COMMENCING WORK. REPORT, IMMEDIATELY, ANY NOTED DISCREPANCIES TO THE ARCHITECT. THE CONTRACTOR SHALL FAMILIARIZE HIM (HER) SELF WITH
EXISTING CONDITIONS BEFORE COMMENCING WORK, INCLUDING, BUT NOT LIMITED TO
EXISTENCE
AND LOCATION OF ASBESTOS, OR OTHER UNKNOWN TOXIC MATERIALS.
4. PROTECTION: CONTRACTOR SHALL PROTECT ALL EXISTING SITE IMPROVEMENTS AND ADJACENT PROPERTY THAT IS SCHEDULED TO REMAIN. CONTRACTOR IS LIABLE FOR ANY DAMAGES TO THE
EXISTING IMPROVEMENTS. CONTRACTOR SHALL CONFINE OPERATIONS TO THE DESIGNATED
CONSTRUCTION AREAS SO AS NOT TO DISRUPT BUILDING TENANTS OR TO MINIMIZE
INTERRUPTIONS.
5. AVAILABLE WORK HOURS: CONTRACTOR MAY BEGIN WORK AT 7 AM WITH LIMITED NOISE UNTIL 8 AM At WHICH TIME WORK MAY PROGRESS IN WHICH TIME WORK MAY PROGRESS IN FULL.
WORK MAY PROCEED UNTIL 5 PM WITH DAILY CLEAN UP ACTIVITIES EXTENDING UNTIL 6 PM
MONDAY - FRIDAY. WORK ON SATURDAYS IS NOT PREFERED AND MAy ONLY BE GRANTED WITH
OWNER CONSENT AND PRIOR APPROVAL.
5. CLEANUP: WORK AREA SHALL BE KEPT CLEAR OF ALL DEBRIS AND TRASH AT ALL TIMES. DO NOT
ALLOW DEBRIS TO ACCUMULATE. CONSTRUCTION MATERIALS, TOOLS, AND TRASH ARE TO BE
TRANSFERRED TO AND FROM THE CONSTRUCTION AREA AS DETERMINED BY THE CONSTRUCTION
MANAGEMENT AND OWNERSHIP.
6. CODES: ALL WORK SHALL BE DONE IN COMPLIANCE WITH ALL CURRENT LOCAL CODES AND
REGULATIONS. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR THE DISCOVERY OF ASBESTOS
AND OTHER REGULATED TOXIC MATERIALS AND SHALL BEAR THE ADMINISTRATIVE RESPONSIBILITY
FOR CONFORMANCES TO FEDERAL, STATE, AND LOCAL CODES FOR DISPOSING OF HAZARDOUS
MATERIALS. SHOULD ANY QUESTIONS ARISE DURING ANY PHASE OF THE CONSTRUCTION, THE
CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ARCHITECT FOR A REVIEW AND CLARIFICATION
PRIOR TO PROCEEDING WITH THAT PORTION OF WORK.
7. BUILDING STANDARDS: UNLESS NOTED OTHERWISE ON THE DRAWINGS, ALL PRODUCTS USED FOR
PATCHING AND REPAIRING OF THE ADJACENT AREAS SHALL MATCH EXISTING MATERIALS AND
COLORS. WHERE PRODUCTS ARE NO LONGER AVAILABLE, CONSULT WITH THE ARCHITECT FOR AN ACCEPTABLE ALTERNATIVE. ALL BRANDS NOTED IN THESE DRAWINGS ARE INTENDED TO REPRESENT THE QUALITY AND TYPE OF MATERIAL THAT WILL BE DEMANDED. ALL SUBSTITUTIONS MUST BE
SUBMITTED TO THE ARCHITECT AND MUST BE EQUAL IN QUALITY, COLOR, TEXTURE, ETC.
8. DEMOLITION: ALL DEMOLITION THAT TAKES PLACE MUST ACCOMMODATE THE NEW WORK
DESIGN LAYOUT. CONTRACTOR TO VERIFY, PRIOR TO BEGINNING WORK, ANY ADDITIONAL
DEMOLITION THAT MAY BE REQUIRED TO SUCCESSFULY COMPLETE THIS RENOVATION.
9. DIMENSIONS: THE CONTRACTOR SHALL LAYOUT ALL NEW CONSTRUCTION TO COORDINATE THESE
DRAWINGS. DO NOT SCALE THESE DRAWINGS WITHOUT REFERRING TO THE DIMENSIONS.
DIMENSIONS ARE APPROXIMATE AND MUST BE FIELD VERIFIED.
10. COORDINATION OF WORK: THE GENERAL CONTRACTOR SHALL COORDINATE JOB OPERATIONS
WITH THE OPERATIONS OF OTHER TRADES DOING ADJACENT WORK, IN ORDER TO PREVENT DELAY AND CONFLICT. ALL PARTS AND MATERIALS PERTINENT TO A MANUFACTURER'S SYSTEM SHALL BE FURNISHED AND INSTALLED WITH THAT SYSTEM. ANY ITEM THAT MAY BE A PART OF A SYSTEM OR
REQUIRED IN THE OPERATION/PERFORMANCE OF A SYSTEM SHALL BE INCLUDED IN THE
CONSTRUCTION.
11. FEES AND PERMITS: THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL FEES AND PERMITS
REQUIRED
AND ASSOCIATED WITH ALL PHASES OF THE WORK AND WITHIN THE SCOPE OR THE CONTRACT
DOCUMENTS INCLUDING BUT NOT LIMITED TO BUILDING PERMIT FEES.
12. SAFETY, WARNING AND HAZARD BARRIERS: THIS WORK MAY BE PERFORMED DURING NORMAL BUSINESS HOURS. IN THIS EVENT, APPROPRIATE SAFETY, WARNING AND HAZARD BARRIERS MUST BE
IN PLACE IN QUANTITIES TO ENSURE THE PROTECTION OF THE PUBLIC.
13. WHEN A REFERENCE IS MADE TO A MATERIAL SYSTEM, ALL PARTS AND MATERIALS PERTINENT TO
THE MANUFACTURERS SYSTEM SPECIFIED SHALL BE FURNISHED AND INSTALLED.
1. CONTRACTOR IS EXPECTED TO BRING AND REMOVE ALL NECESSARY MATERIALS AND EQUIPMENT TO THE SITE EACH DAY AND TO LEAVE NOTHING ON THE SITE OVERNIGHT OR UNSECURED THRU THE WEEKEND WITH THE POSSIBLE EXCEPTION OF A LOCKABLE PORTA POTTY. CONTRACTOR IS RESPONSIBLE
FOR DAILY CLEAN UP AND DEBRIS REMOVAL.
2. THE CONTRACTOR SHOULD MAKE HOURLYASSESMENTS OF THE ON-SITE PARKING TO CONSOLIDATE
CONSTRUCTION VEHICLES CLOSE TO THE CONSTRUCTION AREA TO REDUCE RESIDENT PARKING
DISTURBANCE THROUGHOUT THE DAY.
3. ALL VEHICLES ASSOCIATED WITH THE CONSTRUCTION SITE MAY NOT BLOCK FIRE LANES, HYDRANTS, RESIDENCE ENTRANCES, STOP SIGNS, AND SIDEWALKS. ALL LOADING AND UNLOADING OF
MATERIALS MUST BE KEPT WITHIN THE CONSTRUCTION SITE AREA.
4. CONTRACTOR SHALL LIMIT ALL CONSTRUCTION ACTIVITY TO THE PROPERTY AND FENCED EDGES OF THE THE BUILDINGS BEING REROOFED. PREVENT DISTURBANCE TO NEIGHBORING PROPERTIES.
SITE PLAN NOTES
DURAND-HOLLIS RUPE
ARCHITECTS, INC.
14603 HUEBNER RD.
BUILDING 18
SAN ANTONIO, TEXAS 78230
PHONE: 210/308-0080
FAX: 210/697-3309
eMAIL: office@dhrarchitects.com
THIS DRAWING IS PROVIDED AS AN INSTRUMENT
OF SERVICE BY THE ARCHITECT AND IS INTENDED
FOR USE ON THIS PROJECT ONLY. THE DRAWING
REMAINS THE PROPERTY OF THE ARCHITECT AND
SHALL BE RETURNED TO HIM/HER UPON THE
COMPLETION OF THE CONSTRUCTION WORK.
PERSUANT TO THE ARCHITECTURAL WORKS
COPYRIGHT PROTECTION ACT OF 1990, ALL
DRAWINGS, SPECIFICATIONS, IDEAS AND
DESIGNS, INCLUDING THE OVERALL FORM,
ARRANGEMENT AND COMPOSITION OF SPACES
AND ELEMENTS APPEARING HEREIN, CONSTITUTES
THE COPYRIGHTED WORK OF THE ARCHITECT.
ANY REPRODUCTION, USE, OR DISCLOSURE OF
INFORMATION CONTAINED HEREIN WITHOUT
PRIOR WRITTEN CONSENT OF THE ARCHITECT IS
STRICTLY PROHIBITED.
© 2025
SHEET NO.:
ARCHITECT:
GABRIEL DURAND-HOLLIS, FAIA
LICENSE NUMBER: TX 10881
RO
O
FI
N G A N D W
IN
DO
W R
EP
LA
C
EM
EN
T
O
PP
O
RT
UN
ITY
H O M E
SA
N A N
TO
N
IO
HI
G
HV
IE
W A
PA
RT
M
EN
TS
L
IN
DA
L O U A
PA
RT
M
EN
TS
HIGHVIEW APARTMENTS
ARCHITECTURAL SITE PLAN
PROJECT No. : 25-005
ISSUE DATE: 12/11/25
DRAWN BY: DHR
REVIEWED BY: DHR
A010
R
IG
SB
Y A V E, S A N A N
TO
N
IO
, T X
S H A C
KB
ER
RY
S T, S A N A N
TO
N
IO
, T X
1" = 30'-0"1 HIGH VIEW APARTMENTS SITE PLAN
1" = 20'-0"2 BUILDING TYPE I
1" = 20'-0"4 BUILDING TYPE III
1" = 20'-0"3 BUILDING TYPE II
NORTH
NOTE: THE VARIOUS ROOF ARRANGEMENT AT HIGHVIEW APARTMENTS GENERALLY FALL INTO ONE OF 3 BUILDING TYPES IDENTIFIED HERE. AND DETAILED ON SUBSEQUENT PAGES. CONTRACTOR IS RESPONSIBLE FOR IDENTIFYING AND ADDRESSING ANY UNIQUE
VARIATIONS IN THE EXISTING CONDITIONS IN HTE WORK PERFORMED.
REVISED ISSUE DATES
R002
R001 R001
R002
R002 R004
R005
REMOVE ALL GLAZING AND OPERABLE WINDOW
COMPONENTS FROM ALL EXISTING WINDOW FRAMES AND
PREPARE FOR NEW FLUSH FLANGE REPLACEMENT
WINDOWS
REMOVE EXISTING GUTTERS AND DOWNSPOUTS AND
DISPOSE OF ANY EXISTING SPLASH BLOCKS
EXISTING DOORS TO REMAIN
EXISTING WALLS
TO REMAIN
EXISTING DOORS
TO REMAIN
R001 EXISTING ROOF VENT TO REMAIN. REMOVE EXISTING JACK FLASHING AND PREPARE TO RECEIVE NEW ROOFING
R002 EXISTING EXHAUST VENT TO REMAIN. REMOVE EXISTING JACK FLASHING AND PREPARE TO RECEIVED NEW ROOFING
R004 REMOVED EXISTING ROOFING TO DECK
R005 FASCIA TO REMAIN. CONTRACTOR SHALL PROVIDE UNIT COST FOR REPLACEMENT OF DAMAGED FACIA TRIM AS SPECIFIED
KEY NOTES
R001
R001
C
REMOVE EXISTING GUTTERS AND
DOWNSPOUTS AND DISPOSE OF ANY
EXISTING SPLASH BLOCKS
REMOVE ALL GLAZING AND OPERABLE
WINDOW COMPONENTS FROM ALL
EXISTING WINDOW FRAMES AND PREPARE
FOR NEW FLUSH FLANGE REPLACEMENT
WINDOWS.
EXISTING DOORS
TO REMAIN
EXISTING WALLS
TO REMAIN
R001
REMOVE ALL GLAZING AND OPERABLE
WINDOW COMPONENTS FROM ALL
EXISTING WINDOW FRAMES AND PREPARE
FOR NEW FLUSH FLANGE REPLACEMENT
WINDOWS.
REMOVE EXISTING GUTTERS AND
DOWNSPOUTS AND DISPOSE OF
ANY EXISTING SPLASH BLICKS.
EXISITNG DOORS
TO REMAIN.
EXISITNG WALLS
TO REMAIN.
DEMOLITION GENERAL NOTES
1.
2.
3.
4.
CONTRACTOR TO FIELD VERIFY ALL CONDITIONS
AND DIMENSIONS PRIOR TO BIDDING THE PROJECT.
IT IS THE CONTRACTOR RESPONSIBILITIY TO
MAINTAIN THE BUILDINGS/RESIDENCES WATERTIGHT
THROUGHOUT THE ENTIRE RENOVATION PROJECT.
PATCH, REPAIR AND MATCH ADJACENT AREA
FINISHES WITHIN SCOPE OF WORK.
CONTRACTOR MUST EXAMINE AND VERIFY ALL
EXISTING ROOF PENETRATIONS ARE FUNCTIONING
PROPERLY. ANY EXISTING PENETRATION NOT
FUNCTIONING PROPERLY MUST BE DOCUMENTED
BY THE CONTRACTOR AND BROUGHT TO THE
ATTENTION OF THE ARCHITECT THROUGH AN RFI
BEFORE PROCEDING WITH REPLACEMENT.
5. ALL WORK SHALL MEET MANUFACTURER'S
WARRANTY REQUIREMENTS.
6. CONTRACTOR SHALL COMPLY WITH ALL CURRENT
ADOPTED LOCAL BUILDING CODES WITH
AMENDMENTS. REFER TO COVER SHEET. IF SCOPE
OF WORK SPECIFIED IS IN CONFLICT WITH CODE
REQUIREMENTS THE CONTRACTOR SHALL
INMEDIATELY NOTIFY THE ARCHITECT.
7. CONTRACTOR SHALL PROVIDE PRICING FOR
REPLACEMENT OF DAMAGE WINDOW CASINGS,
ROOF SHEATHING, FASCIA BOARDS AND FOR
REPLACEMENT OF EXISTING SOFFIT SCREENING, UNIT
UNIT PRICING SPECIFICATION SECTION.
8. CONTRACTOR SHALLL IDENTIFY ANY EXISITNG
SATELLITE DISHES. ANTENNAS, WIFI, OR SIMILAR
TRANMISSION CABLES OR SIMILAR ROOF OR FACIA-
MOUNTED EQUIPMENT AND BRING THEM TO THE
ATTENTION OF THE OWNER. OWNER WILL DETERMINE
IF THE EXISTING EQUIPMENT IS TO REMAIN. ALLOW
REASONABLE TIME FOR OWNER ACTION PRIOR TO
COMMENCEMENT OF WORK.
9. REFERENCE SPECIFICATION SECTION 01 1100-
SUMMARY OF WORK FOR SPECIFIC REQUIREMENTS
RELATED TO ALL ROOF AND WINDOW
REPLACEMENT.
DURAND-HOLLIS RUPE
ARCHITECTS, INC.
14603 HUEBNER RD.
BUILDING 18
SAN ANTONIO, TEXAS 78230
PHONE: 210/308-0080
FAX: 210/697-3309
eMAIL: office@dhrarchitects.com
THIS DRAWING IS PROVIDED AS AN INSTRUMENT
OF SERVICE BY THE ARCHITECT AND IS INTENDED
FOR USE ON THIS PROJECT ONLY. THE DRAWING
REMAINS THE PROPERTY OF THE ARCHITECT AND
SHALL BE RETURNED TO HIM/HER UPON THE
COMPLETION OF THE CONSTRUCTION WORK.
PERSUANT TO THE ARCHITECTURAL WORKS
COPYRIGHT PROTECTION ACT OF 1990, ALL
DRAWINGS, SPECIFICATIONS, IDEAS AND
DESIGNS, INCLUDING THE OVERALL FORM,
ARRANGEMENT AND COMPOSITION OF SPACES
AND ELEMENTS APPEARING HEREIN, CONSTITUTES
THE COPYRIGHTED WORK OF THE ARCHITECT.
ANY REPRODUCTION, USE, OR DISCLOSURE OF
INFORMATION CONTAINED HEREIN WITHOUT
PRIOR WRITTEN CONSENT OF THE ARCHITECT IS
STRICTLY PROHIBITED.
© 2025
SHEET NO.:
ARCHITECT:
GABRIEL DURAND-HOLLIS, FAIA
LICENSE NUMBER: TX 10881
RO
O
FI
N G A N D W
IN
DO
W R
EP
LA
C
EM
EN
T
O
PP
O
RT
UN
ITY
H O M E
SA
N A N
TO
N
IO
HI
G
HV
IE
W A
PA
RT
M
EN
TS
L
IN
DA
L O U A
PA
RT
M
EN
TS
HIGHVIEW APARTMENTS
DEMOLITION PLANS
PROJECT No. : 25-005
ISSUE DATE: 12/11/25
DRAWN BY: Author REVIEWED BY: Checker
A100
R
IG
SB
Y A V E, S A N A N
TO
N
IO
, T X
S H A C
KB
ER
RY
S T, S A N A N
TO
N
IO
, T X
3/16" = 1'-0"1 BLDG. TYPE 1 - DEMO PLAN
3/16" = 1'-0"2 BLDG. TYPE II - DEMO PLAN
R001
R004
R005
R001R001 3/16" = 1'-0"3 BUILDING TYPE III
R001
R005
R002
R004
A102
A102
A102
ROOF LINE
7"
2' - 6" 3' - 0" 3' - 0"
3' - 0"6' - 0"
6' - 0"3' - 0"
3' - 0" 3' - 0" 2' - 6"
3'
- 0
3'
- 0
EC
CE
B E D
D E B
E
E
EXISTING DOOR
TO REMAIN TYPICAL
EXISTING BRICK
MANSORY TO REMAIN
EXISTING STUD
WALL TO REMAIN
EXISITNG DOOR
TO REMAIN TYPICAL
69' - 3 1/4"
34' - 5 3/4" 34' - 9 1/2"
1'
- 1 1 3 /4"
7"
1'
- 1 1 3 /4" 4'
- 0 1/ 4" 1'
- 5 3/ 4"
0 1 /2"
TYPICAL
A1075/
A1
A1
3' - 0" 6' - 0"
6' - 0" 3' - 0"
3'
- 0
3'
- 0
2' - 6"3' - 0"
3' - 0"2' - 6"
3'
- 0
3'
- 0
3' - 0"
3' - 0"
76' - 11 173/256"
7"
ROOF LINE
BED
DEB
E
E
E F
F E
EXISITNG DOOR
TO REMAIN
EXISTING STUD
WALLS TO REMAIN
E
E
TYPICAL
A1075/
A1
A1
A1
2' - 6" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 2' - 0"
3' - 0" 3' - 0"
6' - 0" 6' - 0"
3' - 0" 3' - 0" 3'
- 0
3'
- 0
0"
75' - 5"
ROOF LINE
E
E
B E D D E A
E
E
3'
- 0
3'
- 0
EXISTING DOOR
TO REMAIN TYPICAL
EE
FF
EE
TYPICAL
A1075/
3/ A2
DEMOLITION GENERAL NOTES
1.
2.
3.
4.
CONTRACTOR TO FIELD VERIFY ALL CONDITIONS
AND DIMENSIONS PRIOR TO BIDDING THE PROJECT.
IT IS THE CONTRACTOR RESPONSIBILITIY TO
MAINTAIN THE BUILDINGS/RESIDENCES WATERTIGHT
THROUGHOUT THE ENTIRE RENOVATION PROJECT.
PATCH, REPAIR AND MATCH ADJACENT AREA
FINISHES WITHIN SCOPE OF WORK.
CONTRACTOR MUST EXAMINE AND VERIFY ALL
EXISTING ROOF PENETRATIONS ARE FUNCTIONING
PROPERLY. ANY EXISTING PENETRATION NOT
FUNCTIONING PROPERLY MUST BE DOCUMENTED
BY THE CONTRACTOR AND BROUGHT TO THE
ATTENTION OF THE ARCHITECT THROUGH AN RFI
BEFORE PROCEDING WITH REPLACEMENT.
4. ALL WORK SHALL MEET MANUFACTURER'S
WARRANTY REQUIREMENTS.
5. CONTRACTOR SHALL COMPLY WITH ALL CURRENT
ADOPTED LOCAL BUILDING CODES WITH
AMENDMENTS. REFER TO COVER SHEET. IF SCOPE
OF WORK SPECIFIED IS IN CONFLICT WITH CODE
REQUIREMENTS THE CONTRACTOR SHALL
INMEDIATELY NOTIFY THE ARCHITECT.
6. CONTRACTOR SHALL PROVIDE PRICING FOR
REPLACEMENT OF DAMAGE WINDOW CASINGS,
ROOF SHEATHING, FASCIA BOARDS AND FOR
REPLACEMENT OF EXISTING SOFFIT SCREENING, UNIT
UNIT PRICING SPECIFICATION SECTION.
7. CONTRACTOR SHALLL IDENTIFY ANY EXISITNG
SATELLITE DISHES. ANTENNAS, WIFI, OR SIMILAR
TRANMISSION CABLES OR SIMILAR ROOF OR FACIA-
MOUNTED EQUIPMENT AND BRING THEM TO THE
ATTENTION OF THE OWNER. OWNER WILL DETERMINE
IF THE EXISTING EQUIPMENT IS TO REMAIN. ALLOW
REASONABLE TIME FOR OWNER ACTION PRIOR TO
COMMENCEMENT OF WORK.
8. REFERENCE SPECIFICATION SECTION 01 1100-
SUMMARY OF WORK FOR SPECIFIC REQUIREMENTS
RELATED TO ALL ROOF AND WINDOW
REPLACEMENT.
DURAND-HOLLIS RUPE
ARCHITECTS, INC.
14603 HUEBNER RD.
BUILDING 18
SAN ANTONIO, TEXAS 78230
PHONE: 210/308-0080
FAX: 210/697-3309
eMAIL: office@dhrarchitects.com
THIS DRAWING IS PROVIDED AS AN INSTRUMENT
OF SERVICE BY THE ARCHITECT AND IS INTENDED
FOR USE ON THIS PROJECT ONLY. THE DRAWING
REMAINS THE PROPERTY OF THE ARCHITECT AND
SHALL BE RETURNED TO HIM/HER UPON THE
COMPLETION OF THE CONSTRUCTION WORK.
PERSUANT TO THE ARCHITECTURAL WORKS
COPYRIGHT PROTECTION ACT OF 1990, ALL
DRAWINGS, SPECIFICATIONS, IDEAS AND
DESIGNS, INCLUDING THE OVERALL FORM,
ARRANGEMENT AND COMPOSITION OF SPACES
AND ELEMENTS APPEARING HEREIN, CONSTITUTES
THE COPYRIGHTED WORK OF THE ARCHITECT.
ANY REPRODUCTION, USE, OR DISCLOSURE OF
INFORMATION CONTAINED HEREIN WITHOUT
PRIOR WRITTEN CONSENT OF THE ARCHITECT IS
STRICTLY PROHIBITED.
© 2025
SHEET NO.:
ARCHITECT:
GABRIEL DURAND-HOLLIS, FAIA
LICENSE NUMBER: TX 10881
RO
O
FI
N G A N D W
IN
DO
W R
EP
LA
C
EM
EN
T
O
PP
O
RT
UN
ITY
H O M E
SA
N A N
TO
N
IO
HI
G
HV
IE
W A
PA
RT
M
EN
TS
L
IN
DA
L O U A
PA
RT
M
EN
TS
HIGHVIEW APARTMENTS TYPICAL
FLOOR PLANS
PROJECT No. : 25-005
ISSUE DATE: 12/11/25
DRAWN BY: Author REVIEWED BY: Checker
A101
R
IG
SB
Y A V E, S A N A N
TO
N
IO
, T X
S H A C
KB
ER
RY
S T, S A N A N
TO
N
IO
, T X
3/16" = 1'-0"1 BLDG. TYPE I -TYPICAL FLOOR PLAN
3/16" = 1'-0"2 BLDG. TYPE II -TYPICAL FLOOR PLAN
3/16" = 1'-0"3 BLDG. TYPE III -TYPICAL FLOOR PLAN
A102
A102
A102
A102
R021 R007
BLDG. LINE
R007
R001
R001
R001R012R002
R001
R003
R002
R003
R002
R020
A1051/
A1054/
A1052/
A1055/
4" / 1 0"
4" / 1 0"
4" / 1 0"
4" / 1 0"
R012
R021
R021
R018
R018
R021
EXISTING DOOR
TO REMAIN
CONCRETE
SPLASH BLOCKS CONCRETE
SPLASH BLOCKS
CONCRETE
SPLASH BLOCKS
CONCRETE SPLASHBLOCKS
E D
D E
B
B
R007R020
R007R012R008
REPLACE ALL
EXISTING WINDOWS
EXISTING DOOR
TO REMAIN
EXISTING SIDINGS
TO REMAIN
REPLACE ALL
EXISTING WINDOWS
EXISTING SIDINGS
TO REMAIN
EXISTING DOOR
TO REMAIN
EXISTING WOOD
TRIM TO REMAIN
EXISTING WOOD
TRIM TO REMAIN
CONCRETE
SPLASH BLOCKS CONCRETE
SPLASH BLOCKS
E
EXISTING BRICK
SILL TO REMAIN
R007 R012
R012
EXISTING BRICK
MANSORY
TO REMAIN
EXISTING SIDINGS
TO REMAIN
R018
R020
REPLACE ALL
EXISTING
WINDOWS
R008
EXISTING WOOD
TRIM TO REMAIN
EXISTING SIDINGS
TO REMAIN
A1052/
CONCRETE
SPLASH BLOCKS
CONCRETE
SPLASH BLOCKS
E
EXISTING BRICK
SILL TO REMAIN
R012
R007
R020
EXISTING BRICK
MANSORY
TO REMAIN
EXISTING WOOD
TRIM TO REMAIN
EXISTING BRICK
MANSORY
TO REMAIN
EXISTING SIDINGS
TO REMAIN
R008
REMOVE ALL
EXISTING WINDOWS
EXISTING DOOR
TO REMAIN
EXISTING DOOR
TO REMAIN
CONCRETE
SPLASH BLOCKS
CONCRETE
SPLASH BLOCKS
CONCRETE
SPLASH BLOCKS
EC
CE
R008R007R012R020
R007R012
R008
EXISTING BRICK
MANSORY
TO REMAIN
REPLACE ALL
EXISITNG WINDOWS
EXISTING SIDINGS
TO REMAIN
EXISTING WOOD
TRIM TO REMAIN
EXISTING WOOD
TRIM TO REMAIN
EXISTING BRICK
MANSORY
TO REMAIN
EXISTING SIDINGS
TO REMAIN
GENERAL NOTES
1.
2.
3.
4.
CONTRACTOR TO FIELD VERIFY ALL CONDITIONS
AND DIMENSIONS PRIOR TO BIDDING THE PROJECT.
IT IS THE CONTRACTOR RESPONSIBILITIY TO
MAINTAIN THE BUILDINGS/RESIDENCES WATERTIGHT
THROUGHOUT THE ENTIRE RENOVATION PROJECT.
PATCH, REPAIR AND MATCH ADJACENT AREA
FINISHES WITHIN SCOPE OF WORK.
CONTRACTOR MUST EXAMINE AND VERIFY ALL
EXISTING ROOF PENETRATIONS ARE FUNCTIONING
PROPERLY. ANY EXISTING PENETRATION NOT
FUNCTIONING PROPERLY MUST BE DOCUMENTED
BY THE CONTRACTOR AND BROUGHT TO THE
ATTENTION OF THE ARCHITECT THROUGH AN RFI
BEFORE PROCEDING WITH REPLACEMENT.
4. ALL WORK SHALL MEET MANUFACTURER'S
WARRANTY REQUIREMENTS.
5. CONTRACTOR SHALL COMPLY WITH ALL CURRENT
ADOPTED LOCAL BUILDING CODES WITH
AMENDMENTS. REFER TO COVER SHEET. IF SCOPE
OF WORK SPECIFIED IS IN CONFLICT WITH CODE
REQUIREMENTS THE CONTRACTOR SHALL
INMEDIATELY NOTIFY THE ARCHITECT.
6. ALL NEW VENT PIPES SHALL BE NO LESS THAN HALF
THE DIAMETER OF THE EXISTING DRAIN THEY SERVE
7. CONTRACTOR SHALL PROVIDE PRICING FOR
REPLACEMENT OF DAMAGE WINDOW CASINGS,
ROOF SHEATHING, FASCIA BOARDS AND FOR
REPLACEMENT OF EXISTING SOFFIT SCREENING, UNIT
UNIT PRICING SPECIFICATION SECTION.
8. CONTRACTOR SHALL INSPECT ALL EXISTING GAS
EXHAUST VENTS TO VERIFY THEY ARE NOT LEAKING
INTO THE APARTMENT UNITS OR ATTIC AREAS. UPON
COMPLETION OF ROOFING REPLACEMENT ALL GAS
VENTS SHALL BE TESTED TO ENSURE NO EXHAUST
LEAKS EXIST. INFORM THE OWNER OF ANY
DESCREPANCIES.
9. CONTRACTOR SHALLL IDENTIFY ANY EXISITNG
SATELLITE DISHES. ANTENNAS, WIFI, OR SIMILAR
TRANMISSION CABLES OR SIMILAR ROOF OR FACIA-
MOUNTED EQUIPMENT AND BRING THEM TO THE
ATTENTION OF THE OWNER. OWNER WILL DETERMINE
IF THE EXISTING EQUIPMENT IS TO REMAIN. ALLOW
REASONABLE TIME FOR OWNER ACTION PRIOR TO
COMMENCEMENT OF WORK.
10. REFERENCE SPECIFICATION SECTION 01 1100-
SUMMARY OF WORK FOR SPECIFIC REQUIREMENTS
RELATED TO ALL ROOF AND WINDOW
REPLACEMENT.
R001 PLUMBING STACKED VENT
R002 DOUBLE WALL COMBUSTION VENT
R007 REMOVE AND REPLACE GUTTERS
R008 REMOVE AND REPLACE DOWNSPOUT AND CLIPS
R003 ROOF JACK WITH VENT CAP
R012 REMOVE EXISTING ROOFING TO DECK AND REPLACE AS SPECIFIED
R018 FASCIA WITH DRIP EDGE
R020 REMOVE AND REPLACE RIDGE VENT
R021 GUTTER WITH DOWNSPOUTS
KEY NOTES
NOTES:
ALTENATE #1: PROVIDE A MINIMUM OF R-38 INSULATION TO ALL ATTIC AND CRAWL
SPACES TO BRING THE ROOF INSULATION OF THESE BUILDINGS INTO GENERAL
COMPLIANCE WITH THE INTERNATIONAL ENERGY CONSERVATION CODE 2021
REQUIREMENTS FOR THERMAL PERFORMANCE OF THE ROOF ASSEMBLIES. CONTRACTOR
SHALL BE REQUIRED TO ACCESS AREAS ABOVE THE OCCUPIED SPACES VIA ACCESS
OPENINGS CUT THRU EXISTING ROOF DECK.
DURAND-HOLLIS RUPE
ARCHITECTS, INC.
14603 HUEBNER RD.
BUILDING 18
SAN ANTONIO, TEXAS 78230
PHONE: 210/308-0080
FAX: 210/697-3309
eMAIL: office@dhrarchitects.com
THIS DRAWING IS PROVIDED AS AN INSTRUMENT
OF SERVICE BY THE ARCHITECT AND IS INTENDED
FOR USE ON THIS PROJECT ONLY. THE DRAWING
REMAINS THE PROPERTY OF THE ARCHITECT AND
SHALL BE RETURNED TO HIM/HER UPON THE
COMPLETION OF THE CONSTRUCTION WORK.
PERSUANT TO THE ARCHITECTURAL WORKS
COPYRIGHT PROTECTION ACT OF 1990, ALL
DRAWINGS, SPECIFICATIONS, IDEAS AND
DESIGNS, INCLUDING THE OVERALL FORM,
ARRANGEMENT AND COMPOSITION OF SPACES
AND ELEMENTS APPEARING HEREIN, CONSTITUTES
THE COPYRIGHTED WORK OF THE ARCHITECT.
ANY REPRODUCTION, USE, OR DISCLOSURE OF
INFORMATION CONTAINED HEREIN WITHOUT
PRIOR WRITTEN CONSENT OF THE ARCHITECT IS
STRICTLY PROHIBITED.
© 2025
SHEET NO.:
ARCHITECT:
GABRIEL DURAND-HOLLIS, FAIA
LICENSE NUMBER: TX 10881
RO
O
FI
N G A N D W
IN
DO
W R
EP
LA
C
EM
EN
T
O
PP
O
RT
UN
ITY
H O M E
SA
N A N
TO
N
IO
HI
G
HV
IE
W A
PA
RT
M
EN
TS
L
IN
DA
L O U A
PA
RT
M
EN
TS
HIGHVIEW APARTMENTS
BUILDING TYPE I - TYPICAL
PROJECT No. : 25-005
ISSUE DATE: 12/11/25
DRAWN BY: DHR
REVIEWED BY: DHR
A102
R
IG
SB
Y A V E, S A N A N
TO
N
IO
, T X
S H A C
KB
ER
RY
S T, S A N A N
TO
N
IO
, T X
1/4" = 1'-0"1 BLDG. TYPE I -TYPICAL ROOF PLAN
1/4" = 1'-0"3 BLDG. TYPE I - TYPICAL NORTH ELEVATION
1/4" = 1'-0"4 BLDG. TYPE I - TYPICAL EAST ELEVATION
1/4" = 1'-0"5 BLDG. TYPE I - TYPICAL WEST ELEVATION
1/4" = 1'-0"2 BLDG. TYPE I - TYPICAL SOUTH ELEVATION
GENERAL NOTES
1.
2.
3.
4.
CONTRACTOR TO FIELD VERIFY ALL CONDITIONS
AND DIMENSIONS PRIOR TO BIDDING THE PROJECT.
IT IS THE CONTRACTOR RESPONSIBILITIY TO
MAINTAIN THE BUILDINGS/RESIDENCES WATERTIGHT
THROUGHOUT THE ENTIRE RENOVATION PROJECT.
PATCH, REPAIR AND MATCH ADJACENT AREA
FINISHES WITHIN SCOPE OF WORK.
CONTRACTOR MUST EXAMINE AND VERIFY ALL
EXISTING ROOF PENETRATIONS ARE FUNCTIONING
PROPERLY. ANY EXISTING PENETRATION NOT
FUNCTIONING PROPERLY MUST BE DOCUMENTED
BY THE CONTRACTOR AND BROUGHT TO THE
ATTENTION OF THE ARCHITECT THROUGH AN RFI
BEFORE PROCEDING WITH REPLACEMENT.
4. ALL WORK SHALL MEET MANUFACTURER'S
WARRANTY REQUIREMENTS.
5. CONTRACTOR SHALL COMPLY WITH ALL CURRENT
ADOPTED LOCAL BUILDING CODES WITH
AMENDMENTS. REFER TO COVER SHEET. IF SCOPE
OF WORK SPECIFIED IS IN CONFLICT WITH CODE
REQUIREMENTS THE CONTRACTOR SHALL
INMEDIATELY NOTIFY THE ARCHITECT.
6. ALL NEW VENT PIPES SHALL BE NO LESS THAN HALF
THE DIAMETER OF THE EXISTING DRAIN THEY SERVE
7. CONTRACTOR SHALL PROVIDE PRICING FOR
REPLACEMENT OF DAMAGE WINDOW CASINGS,
ROOF SHEATHING, FASCIA BOARDS AND FOR
REPLACEMENT OF EXISTING SOFFIT SCREENING, UNIT
UNIT PRICING SPECIFICATION SECTION.
8. CONTRACTOR SHALL INSPECT ALL EXISTING GAS
EXHAUST VENTS TO VERIFY THEY ARE NOT LEAKING
INTO THE APARTMENT UNITS OR ATTIC AREAS. UPON
COMPLETION OF ROOFING REPLACEMENT ALL GAS
VENTS SHALL BE TESTED TO ENSURE NO EXHAUST
LEAKS EXIST. INFORM THE OWNER OF ANY
DESCREPANCIES.
9. CONTRACTOR SHALLL IDENTIFY ANY EXISITNG
SATELLITE DISHES. ANTENNAS, WIFI, OR SIMILAR
TRANMISSION CABLES OR SIMILAR ROOF OR FACIA-
MOUNTED EQUIPMENT AND BRING THEM TO THE
ATTENTION OF THE OWNER. OWNER WILL DETERMINE
IF THE EXISTING EQUIPMENT IS TO REMAIN. ALLOW
REASONABLE TIME FOR OWNER ACTION PRIOR TO
COMMENCEMENT OF WORK.
10. REFERENCE SPECIFICATION SECTION 01 1100-
SUMMARY OF WORK FOR SPECIFIC REQUIREMENTS
RELATED TO ALL ROOF AND WINDOW
REPLACEMENT.
A1
A1
A1
A1
R007R012
R021
R020
R001
R001R001
R020
A1051/
A1054/
A1055/
A1053/ A1053/
R007
4" / 1 0"
4" / 1 0"
4" / 1 0"
4" / 1 0"
4" / 1' - 0"4" / 1' - 0"
A1052/
R012
R021
R018
R007
R021 R007
EXISTING DOOR
TO REMAIN
EXISTING DOOR
TO REMAIN
CONC. SPLASH
BLOCKS
CONC. SPLASH
BLOCKS
CONC. SPLASH
BLOCKS
CONC. SPLASH
BLOCKS
BE
DD
EB
EXISTING DOOR
TO REMAIN
R020R001R012R020 R001R012R007
EXISTING SIDINGS
TO REMAIN
EXISTING STONE
MANSORY TO REMAIN
R008
REPLACE ALL
EXISTING
WINDOWS
EXISTING
WOOD TRIM
TO REMAIN
REPLACE ALL
EXISTING WINDOWS
EXISTING SIDINGS
TO REMAIN
A1054/
E E
EXISTING BRICK
SILL TO REMAIN
R012 R001
EXISTING STONE
MANSORY
TO REMAIN
EXISTING WOOD
TRIM TO REMAIN
REPLACE ALL
EXISTING
WINDOWS
R020
R008 R008
EXISTING SIDINGS
TO REMAIN
A1052/
CONC.
SPLASH BLOCK
EE
EXISTING BRICK
SILL TO REMAIN
R020R012
EXISTING WOOD
TRIM TO REMAIN
REPLACE ALL
EXISTING WINDOWS
EXISTING SIDINGS
TO REMAIN
EXISTING STONE
MANSORY TO REMAIN
EXISTING SIDINGS
TO REMAIN
R008
R018
EXISTING DOOR
TO REMAIN
EXISTING DOOR
TO REMAIN
CONC. SPLASH
BLOCKS
CONC. SPLASH
BLOCKS
CONC. SPLASH
BLOCKS
CONC. SPLASH
BLOCKS
E FF E
6' - 0"
R012R020R012 R001
EXISTING STONE
MANSORY
TO REMAIN
EXISTING SIDINGS
TO REMAIN
REPLACE ALL
EXISTING
WINDOWS
EXISTING WOOD
TRIM TO REMAIN
EXISTING WOOD
TRIM TO REMAIN
EXISTING STONE
MANSORY TO
REMAIN
R020
EXISTING SIDINGS
TO REMAIN
EXISTING SIDINGS
TO REMAIN
REPLACE ALL
EXISTING
WINDOWS
R008
R001 PLUMBING STACKED VENT
R002 DOUBLE WALL COMBUSTION VENT
R007 REMOVE AND REPLACE GUTTERS
R008 REMOVE AND REPLACE DOWNSPOUT AND CLIPS
R003 ROOF JACK WITH VENT CAP
R012 REMOVE EXISTING ROOFING TO DECK AND REPLACE AS SPECIFIED
R018 FASCIA WITH DRIP EDGE
R020 REMOVE AND REPLACE RIDGE VENT
R021 GUTTER WITH DOWNSPOUTS
KEY NOTES
NOTES:
ALTENATE #1: PROVIDE A MINIMUM OF R-38 INSULATION TO ALL ATTIC AND CRAWL
SPACES TO BRING THE ROOF INSULATION OF THESE BUILDINGS INTO GENERAL
COMPLIANCE WITH THE INTERNATIONAL ENERGY CONSERVATION CODE 2021
REQUIREMENTS FOR THERMAL PERFORMANCE OF THE ROOF ASSEMBLIES. CONTRACTOR
SHALL BE REQUIRED TO ACCESS AREAS ABOVE THE OCCUPIED SPACES VIA ACCESS
OPENINGS CUT THRU EXISTING ROOF DECK.
DURAND-HOLLIS RUPE
ARCHITECTS, INC.
14603 HUEBNER RD.
BUILDING 18
SAN ANTONIO, TEXAS 78230
PHONE: 210/308-0080
FAX: 210/697-3309
eMAIL: office@dhrarchitects.com
THIS DRAWING IS PROVIDED AS AN INSTRUMENT
OF SERVICE BY THE ARCHITECT AND IS INTENDED
FOR USE ON THIS PROJECT ONLY. THE DRAWING
REMAINS THE PROPERTY OF THE ARCHITECT AND
SHALL BE RETURNED TO HIM/HER UPON THE
COMPLETION OF THE CONSTRUCTION WORK.
PERSUANT TO THE ARCHITECTURAL WORKS
COPYRIGHT PROTECTION ACT OF 1990, ALL
DRAWINGS, SPECIFICATIONS, IDEAS AND
DESIGNS, INCLUDING THE OVERALL FORM,
ARRANGEMENT AND COMPOSITION OF SPACES
AND ELEMENTS APPEARING HEREIN, CONSTITUTES
THE COPYRIGHTED WORK OF THE ARCHITECT.
ANY REPRODUCTION, USE, OR DISCLOSURE OF
INFORMATION CONTAINED HEREIN WITHOUT
PRIOR WRITTEN CONSENT OF THE ARCHITECT IS
STRICTLY PROHIBITED.
© 2025
SHEET NO.:
ARCHITECT:
GABRIEL DURAND-HOLLIS, FAIA
LICENSE NUMBER: TX 10881
RO
O
FI
N G A N D W
IN
DO
W R
EP
LA
C
EM
EN
T
O
PP
O
RT
UN
ITY
H O M E
SA
N A N
TO
N
IO
HI
G
HV
IE
W A
PA
RT
M
EN
TS
L
IN
DA
L O U A
PA
RT
M
EN
TS
HIGHVIEW APARTMENTS
BUILDING TYPE II - TYPICAL
PROJECT No. : 25-005
ISSUE DATE: 12/11/25
DRAWN BY: DHR
REVIEWED BY: DHR
A103
R
IG
SB
Y A V E, S A N A N
TO
N
IO
, T X
S H A C
KB
ER
RY
S T, S A N A N
TO
N
IO
, T X
1/4" = 1'-0"1 BLDG. TYPE II -TYPICAL ROOF PLAN
1/4" = 1'-0"4 BLDG. TYPE II - TYPICAL EAST ELEVATION
1/4" = 1'-0"2 BLDG. TYPE II - TYPICAL NORTH ELEVATION
1/4" = 1'-0"3 BLDG. TYPE II - TYPICAL SOUTH ELEVATION
1/4" = 1'-0"5 BLDG. TYPE II - TYPICAL WEST ELEVATION
2.
3.
4.
CONTRACTOR TO FIELD VERIFY ALL CONDITIONS
AND DIMENSIONS PRIOR TO BIDDING THE PROJECT.
IT IS THE CONTRACTOR RESPONSIBILITIY TO
MAINTAIN THE BUILDINGS/RESIDENCES WATERTIGHT
THROUGHOUT THE ENTIRE RENOVATION PROJECT.
PATCH, REPAIR AND MATCH ADJACENT AREA
FINISHES WITHIN SCOPE OF WORK.
CONTRACTOR MUST EXAMINE AND VERIFY ALL
EXISTING ROOF PENETRATIONS ARE FUNCTIONING
PROPERLY. ANY EXISTING PENETRATION NOT
FUNCTIONING PROPERLY MUST BE DOCUMENTED
BY THE CONTRACTOR AND BROUGHT TO THE
ATTENTION OF THE ARCHITECT THROUGH AN RFI
BEFORE PROCEDING WITH REPLACEMENT.
4. ALL WORK SHALL MEET MANUFACTURER'S
WARRANTY REQUIREMENTS.
5. CONTRACTOR SHALL COMPLY WITH ALL CURRENT
ADOPTED LOCAL BUILDING CODES WITH
AMENDMENTS. REFER TO COVER SHEET. IF SCOPE
OF WORK SPECIFIED IS IN CONFLICT WITH CODE
REQUIREMENTS THE CONTRACTOR SHALL
INMEDIATELY NOTIFY THE ARCHITECT.
6. ALL NEW VENT PIPES SHALL BE NO LESS THAN HALF
THE DIAMETER OF THE EXISTING DRAIN THEY SERVE
7. CONTRACTOR SHALL PROVIDE PRICING FOR
REPLACEMENT OF DAMAGE WINDOW CASINGS,
ROOF SHEATHING, FASCIA BOARDS AND FOR
REPLACEMENT OF EXISTING SOFFIT SCREENING, UNIT
UNIT PRICING SPECIFICATION SECTION.
8. CONTRACTOR SHALL INSPECT ALL EXISTING GAS
EXHAUST VENTS TO VERIFY THEY ARE NOT LEAKING
INTO THE APARTMENT UNITS OR ATTIC AREAS. UPON
COMPLETION OF ROOFING REPLACEMENT ALL GAS
VENTS SHALL BE TESTED TO ENSURE NO EXHAUST
LEAKS EXIST. INFORM THE OWNER OF ANY
DESCREPANCIES.
9. CONTRACTOR SHALLL IDENTIFY ANY EXISITNG
SATELLITE DISHES. ANTENNAS, WIFI, OR SIMILAR
TRANMISSION CABLES OR SIMILAR ROOF OR FACIA-
MOUNTED EQUIPMENT AND BRING THEM TO THE
ATTENTION OF THE OWNER. OWNER WILL DETERMINE
IF THE EXISTING EQUIPMENT IS TO REMAIN. ALLOW
REASONABLE TIME FOR OWNER ACTION PRIOR TO
COMMENCEMENT OF WORK.
10. REFERENCE SPECIFICATION SECTION 01 1100-
SUMMARY OF WORK FOR SPECIFIC REQUIREMENTS
RELATED TO ALL ROOF AND WINDOW
REPLACEMENT.
A1
A1
A1
A1
R012
R008R007R018
R001
R020 R020
4" 1'
- 0
4" 1'
- 0
4" 1'
- 0
4" 1'
- 0
4" 1'
- 0
4" 1'
- 0
A1054/
A1052/A1055/
R021 R012
R020
R018
R021 R007 R021
R007
CONC.SPLASH
BLOCKS
CONC.SPLASH
BLOCKS
CONC.SPLASH
BLOCKS
CONC.SPLASH
BLOCKS CONC.SPLASH
BLOCKS
EE F F E E
R008R007R012
R020R012
R001R012R007
EXISTING BRICK
MANSORY TO
REMAIN
REPLACE ALL
EXISTING WINDOWS
EXISTING SIDINGS
TO REMAIN
EXISTING WOOD
TRIM TO REMAIN
EXISTING SIDINGS
TO REMAIN
EXISTING BRICK
MANSORY TO REMAIN
REPLACE ALL
EXISTING WINDOWS
EXISTING BRICK
MANSORY TO REMAIN
R020
R008
4" / 1'-0"
CONCRETE
SPLASH BLOCKS
CONCRETE SPLASH BLOCKS
EE
EXISTING BRICK SILL TO REMAIN
R007
R020
REPLACE ALL EXISTING
WINDOWS
EXISTING BRICK
MANSORY TO REMAIN
EXISTING SIDINGS
TO REMAIN
R008
R018
4" / 1'-0"
CONCRETE SPLASH BLOCKS CONCRETE SPLASH BLOCKS
EE
EXISITNG BRICK SILL TO REMAIN
R008R018
EXISTING SIDINGS
TO REMAIN
R001
REPLACE ALL
EXISITNG WINDOWS
EXISTING BRICK
MANSORY
TO REMAIN
EXISTING WOOD
TRIM TO REMAIN
EXISTING DOOR
TO REMAIN
CONCRETE
SPLASH BLOCKS
EXISTING DOOR TO REMAIN
CONCRETE
SPLASH BLOCKS
E D D
E B
A
EXISTING SIDINGS
TO REMAIN
EXISTING WOOD
TRIM TO REMAIN
EXISTING DOOR
TO REMAIN
R008R007R012 R020
R001R012
EXISTING BRICK
MANSORY TO
REMIAN
REPLACE ALL
EXISTING
WINDOWS
R020
EXISTING BRICK
MANSORY TO
REMAIN
R008
EXISTING DOOR
TO REMAIN
R001 PLUMBING STACKED VENT
R002 DOUBLE WALL COMBUSTION VENT
R007 REMOVE AND REPLACE GUTTERS
R008 REMOVE AND REPLACE DOWNSPOUT AND CLIPS
R003 ROOF JACK WITH VENT CAP
R012 REMOVE EXISTING ROOFING TO DECK AND REPLACE AS SPECIFIED
R018 FASCIA WITH DRIP EDGE
R020 REMOVE AND REPLACE RIDGE VENT
R021 GUTTER WITH DOWNSPOUTS
KEY NOTES
NOTES:
ALTENATE #1: PROVIDE A MINIMUM OF R-38 INSULATION TO ALL ATTIC AND CRAWL
SPACES TO BRING THE ROOF INSULATION OF THESE BUILDINGS INTO GENERAL
COMPLIANCE WITH THE INTERNATIONAL ENERGY CONSERVATION CODE 2021
REQUIREMENTS FOR THERMAL PERFORMANCE OF THE ROOF ASSEMBLIES. CONTRACTOR
SHALL BE REQUIRED TO ACCESS AREAS ABOVE THE OCCUPIED SPACES VIA ACCESS
OPENINGS CUT THRU EXISTING ROOF DECK.
1/4" = 1'-0"2 BLDG. TYPE III - TYPICAL NORTH ELEVATION
DURAND-HOLLIS RUPE
ARCHITECTS, INC.
14603 HUEBNER RD.
BUILDING 18
SAN ANTONIO, TEXAS 78230
PHONE: 210/308-0080
FAX: 210/697-3309
eMAIL: office@dhrarchitects.com
THIS DRAWING IS PROVIDED AS AN INSTRUMENT
OF SERVICE BY THE ARCHITECT AND IS INTENDED
FOR USE ON THIS PROJECT ONLY. THE DRAWING
REMAINS THE PROPERTY OF THE ARCHITECT AND
SHALL BE RETURNED TO HIM/HER UPON THE
COMPLETION OF THE CONSTRUCTION WORK.
PERSUANT TO THE ARCHITECTURAL WORKS
COPYRIGHT PROTECTION ACT OF 1990, ALL
DRAWINGS, SPECIFICATIONS, IDEAS AND
DESIGNS, INCLUDING THE OVERALL FORM,
ARRANGEMENT AND COMPOSITION OF SPACES
AND ELEMENTS APPEARING HEREIN, CONSTITUTES
THE COPYRIGHTED WORK OF THE ARCHITECT.
ANY REPRODUCTION, USE, OR DISCLOSURE OF
INFORMATION CONTAINED HEREIN WITHOUT
PRIOR WRITTEN CONSENT OF THE ARCHITECT IS
STRICTLY PROHIBITED.
© 2025
SHEET NO.:
ARCHITECT:
GABRIEL DURAND-HOLLIS, FAIA
LICENSE NUMBER: TX 10881
RO
O
FI
N G A N D W
IN
DO
W R
EP
LA
C
EM
EN
T
O
PP
O
RT
UN
ITY
H O M E
SA
N A N
TO
N
IO
HI
G
HV
IE
W A
PA
RT
M
EN
TS
L
IN
DA
L O U A
PA
RT
M
EN
TS
HIGHVIEW APARTMENTS
BUILDING TYPE III - TYPICAL
PROJECT No. : 25-005
ISSUE DATE: 12/11/25
DRAWN BY: DHR
REVIEWED BY: DHR
A104
R
IG
SB
Y A V E, S A N A N
TO
N
IO
, T X
S H A C
KB
ER
RY
S T, S A N A N
TO
N
IO
, T X
1/4" = 1'-0"1 BLDG. TYPE III -TYPICAL ROOF PLAN
1/4" = 1'-0"4 BLDG. TYPE III - TYPICAL EAST ELEVATION
1/4" = 1'-0"3 BLDG. TYPE III - TYPICAL SOUTH ELEVATION
1/4" = 1'-0"5 BLDG. TYPE III - TYPICAL WEST ELEVATION
EXISTING EXTERIOR SHEATHING &
WEATHER BARRIER TO REMAIN
TRIM BOARD
"Z" FLASHING. INSTALL FASTENERS EVERY
8" TO TERMINATE STEP FLASHING AND
WATERPROOFING MEMBRANE.
EXISTING ROOF SHEATHING TO REMAIN.
REPLACE DAMAGED SHEATHING AS REQUIRED.
NOTE:
24 GAUGE REQUIRED FOR ALL
TERMINATION METALS.
" M
IN
. E
XI
ST
IN
G
SI
DI
NG
RE
MO
VE
E
XI
ST
IN
G
SI
DI
NG
EXISITNG ROOF SHEATHING
EXISITNG TRIM TO REMAIN
FLASHING
IN-WALL
REGLET
SEALANT
EXISTING
WATERPROOFING TO
REMAIN
ASPHALT SHINGLE ROOF
DRIP FLASHING
PRE-FINISHED
GUTTER &
DOWNSPOUT
NOTE:
24 GAUGE REQUIRED FOR ALL
TERMINATION METALS.
PEEL AND STICK
ROOF MEMBRANE
UPPER FASCIA BOARD
EXISTING CONTINUOUS
SCREENED SOFFIT
PANELS TO REMAIN.
REPAIR OR REPLACE
DAMAGED SCREENING AS
SPECIFIED.
CONTINOUS CLEAT
ALUMINUM GUTTER
@ 24" O.C.
GUTTER STRAP
@ 24" O.C.
GUTTER SCREEN
SOFFIT SCREEN
ASPHALT SHINGLE ROOF
PEEL AND STICK
ROOF MEMBRANE
DRIP FLASHING
NOTE:
24 GAUGE REQUIRED FOR ALL
TERMINATION METALS.
UPPER FASCIA
BOARD
EXISTING ROOF
SHEATHING
CONTINOUS CLEAT
ROOFING MEMBRANE
CONT. RIDGE VENT.
EXISTING ROOF
SHEATHING
NOTE:
24 GAUGE REQUIRED FOR ALL
TERMINATION METALS.
PEEL AND STICK
ROOF MEMBRANE
ALTERNATE DIRECTION
OF SHINGLE-CAP
OVERLAPS
1" MIN.
SLOPE
METAL FLASH
ING
0' - 6" MIN
0' - 1 117/12
8"
SLOPE
EXISTING ROOF SHEATHING
TO REMAIN
PEEL AND STICK
ROOF MEMBRANE
DIVERTER FLASHINGASPHALT SHINGLE ROOF
NOTE:
24 GAUGE REQUIRED FOR ALL
TERMINATION METALS.
COVER BOARD
45 MIL SA UNDERLAYNMENT OVERLAPPED 2"
GUTTER BRACKET.
GUTTER STRAPS.
DRIP FLASHING.
PRE-FINISHED
GUTTER.
DURAND-HOLLIS RUPE
ARCHITECTS, INC.
14603 HUEBNER RD.
BUILDING 18
SAN ANTONIO, TEXAS 78230
PHONE: 210/308-0080
FAX: 210/697-3309
eMAIL: office@dhrarchitects.com
THIS DRAWING IS PROVIDED AS AN INSTRUMENT
OF SERVICE BY THE ARCHITECT AND IS INTENDED
FOR USE ON THIS PROJECT ONLY. THE DRAWING
REMAINS THE PROPERTY OF THE ARCHITECT AND
SHALL BE RETURNED TO HIM/HER UPON THE
COMPLETION OF THE CONSTRUCTION WORK.
PERSUANT TO THE ARCHITECTURAL WORKS
COPYRIGHT PROTECTION ACT OF 1990, ALL
DRAWINGS, SPECIFICATIONS, IDEAS AND
DESIGNS, INCLUDING THE OVERALL FORM,
ARRANGEMENT AND COMPOSITION OF SPACES
AND ELEMENTS APPEARING HEREIN, CONSTITUTES
THE COPYRIGHTED WORK OF THE ARCHITECT.
ANY REPRODUCTION, USE, OR DISCLOSURE OF
INFORMATION CONTAINED HEREIN WITHOUT
PRIOR WRITTEN CONSENT OF THE ARCHITECT IS
STRICTLY PROHIBITED.
© 2025
SHEET NO.:
ARCHITECT:
GABRIEL DURAND-HOLLIS, FAIA
LICENSE NUMBER: TX 10881
RO
O
FI
N G A N D W
IN
DO
W R
EP
LA
C
EM
EN
T
O
PP
O
RT
UN
ITY
H O M E
SA
N A N
TO
N
IO
HI
G
HV
IE
W A
PA
RT
M
EN
TS
L
IN
DA
L O U A
PA
RT
M
EN
TS
HIGHVIEW APARTMENTS
RE-ROOFING DETAILS
PROJECT No. : 25-005
ISSUE DATE: 12/11/25
DRAWN BY: DHR
REVIEWED BY: DHR
A105
R
IG
SB
Y A V E, S A N A N
TO
N
IO
, T X
S H A C
KB
ER
RY
S T, S A N A N
TO
N
IO
, T X
3" = 1'-0"1 ROOF TO WALL CONNECTION
3" = 1'-0"2 ROOF EDGE
3" = 1'-0"5 ROOF EDGE @ ROOF RAKE
3" = 1'-0"4 ROOF RIDGE
3" = 1'-0"3 ROOF @ VALLEY
1/4" = 1'-0"7 SHINGLE EAVE AT GUTTER
WINDOW TYPES
1'
- 0
5'
- 9 3/ 4"
A B C D E F
OPERABLE SLIDING WINDOW OPERABLE SLIDING WINDOW OPERABLE SLIDING WINDOW OPERABLE HUNG WINDOW OPERABLE HUNG WINDOW OPERABLE HUNG WINDOW
6' - 0"3' - 0"
5'
- 0
5'
- 0
2' - 6"
2'
- 0
4'
- 9 3/ 4"
3' - 0"
3'
- 0
4'
- 0
6' - 0"
5'
- 0
2'
- 0
2'
- 0
2'
- 0
7'
- 0
1/A107
2/A107
3/A107
1/A107 1/A107 1/A107 1/A107 1/A107
2/A107
2/A107
2/A107 2/A107 2/A107
3/A107
3/A107
3/A107
3/A107 3/A107
NOTE: FIELD VERIFY MEASUREMENT
WINDOW REPLACEMENT GENERAL NOTES
1. REFERENCE SPECIFICATION SECTION 01 1100 SUMMARY OF
WORK FOR SPECIFIC WINDOW REPLACEMENT REQUIREMENTS.
2. WINDOW BLINDS, CONTRACTOR SHALL PROVIDE BALI BLINDS "
LIGHTBLOCKER" 1" MINI-BLINDS OR EQUAL.APPROVED BY THE
OWNER OFFERING MINIMUM 8-GAUGE ALUMINUM SLATS AND
CORDLESS LIFT AND WAND TILT FUNCTION AT ALL WINDOWS.
COLOR TO BE SELECTED FROM MANUFACTURER'S FULL RANGE
OF AVAILABLE COLORS.
3. PROVIDE SCREENS AT ALL OPERABLE WINDOWS
4. CONTRACTOR SHALL PROVIDE ADDITIONAL BRACKETS AS
REQUIRED TO SUPPORT RE- INSTALLATION OF WINDOW UNITS.
5. CONTRACTOR TO REMOVE ANY SECURITY SCREENS
INSTTALED AT EXISTING WINDOWS.
DURAND-HOLLIS RUPE
ARCHITECTS, INC.
14603 HUEBNER RD.
BUILDING 18
SAN ANTONIO, TEXAS 78230
PHONE: 210/308-0080
FAX: 210/697-3309
eMAIL: office@dhrarchitects.com
THIS DRAWING IS PROVIDED AS AN INSTRUMENT
OF SERVICE BY THE ARCHITECT AND IS INTENDED
FOR USE ON THIS PROJECT ONLY. THE DRAWING
REMAINS THE PROPERTY OF THE ARCHITECT AND
SHALL BE RETURNED TO HIM/HER UPON THE
COMPLETION OF THE CONSTRUCTION WORK.
PERSUANT TO THE ARCHITECTURAL WORKS
COPYRIGHT PROTECTION ACT OF 1990, ALL
DRAWINGS, SPECIFICATIONS, IDEAS AND
DESIGNS, INCLUDING THE OVERALL FORM,
ARRANGEMENT AND COMPOSITION OF SPACES
AND ELEMENTS APPEARING HEREIN, CONSTITUTES
THE COPYRIGHTED WORK OF THE ARCHITECT.
ANY REPRODUCTION, USE, OR DISCLOSURE OF
INFORMATION CONTAINED HEREIN WITHOUT
PRIOR WRITTEN CONSENT OF THE ARCHITECT IS
STRICTLY PROHIBITED.
© 2025
SHEET NO.:
ARCHITECT:
GABRIEL DURAND-HOLLIS, FAIA
LICENSE NUMBER: TX 10881
RO
O
FI
N G A N D W
IN
DO
W R
EP
LA
C
EM
EN
T
O
PP
O
RT
UN
ITY
H O M E
SA
N A N
TO
N
IO
HI
G
HV
IE
W A
PA
RT
M
EN
TS
L
IN
DA
L O U A
PA
RT
M
EN
TS
HIGHVIEW APARTMENTS
WINDOW TYPES
PROJECT No. : 25-005
ISSUE DATE: 12/11/25
DRAWN BY: DHR
REVIEWED BY: DHR
A106
R
IG
SB
Y A V E, S A N A N
TO
N
IO
, T X
S H A C
KB
ER
RY
S T, S A N A N
TO
N
IO
, T X
2.
3.
4.
5.
6.
7.
8.
1. THE EXISTING CONSTRUCTION OF THESE APARTMNETS
INCLUDES HAZARDOUS MATERIALS. THERE IS EVIDENCE
OF BOTH ASBESTOS CONTAINING MATERIALS AND LEAD
BASED PAINT IN EXISTING AREAS NOT INTENDED TO BE
DISTURBED BY HTIS WORK. LIMITED ASBESTOS AND LEAD
CONTANING PAINT SURVEY REPORTS ARE INCLUDED IN THE
SPECIFICATIONS. THEY IDENTIFY CHRYSOTILE MATERIALS
IN THE EXISTING SHEETROCK WALLS AND CEILING GYPSUM
BOARD CONSTRUCTION AS WELL AS IN THE ORIGINAL
FLOOR TILE AND MASTIC. IN ADDITION, LEAD BASED PAINT
WAS FOUND TO EXIST TO SAMPLES TESTED INCLUDING THE
VARIOUS COLORS APPLIED TO THE INTERIOR WALLS,
CEILING, DOORS AND DOOR FRAMES, WINDOW SILL AND
TRIM AS WELL AS BASEDBOARDS. CONTRACTOR SHALL
SHALL TAKE EVERY EFFORT TO AVOID DISTURBANCE OF
EXISTING WORK IN PLACE NOT SPECIFICALLY REQUIRED BY
THESE CONSTRUCTION ACTIVITIES. CONTRACTOR SHALL
EXERCISE PROPER OSHA PROCEDURES FOR PERSONNEL
PROTECTION AND SHALL EMPLOY PROTECTIVE MEASURES
WHEN DISTURBING ANY EXISTING SHEET ROCK OR PAINTED
SURFACES. PLANNED ACTIVITIES IMPACTING THOSE
MATERIALS DETERMINED TO CONTAIN MEASURABLE
CONCENTRATIONS OF LEAD WILL BE SUBJECT TO OSHA
REGULATIONS IS THE RESPONSIBILITY OF THE
CONTRACTOR. REVIEW PROCEDURES WITH OWNER PRIOR
TO ANY REQUIRED DISTURBANCES.
2. CONTRACTOR TO VERIFY THE EXISTING WINDOW FRAME IS
NOT DETERIORATED. PRIOR TO THE INSTALLATION, INSPECT
THE WINDOW FRAME PERIMETER FOR EVIDENCE OF DAMAGE
OR DECAY.
CONTRACTOR TO FIELD VERIFY ALL EXISTING WINDOWS
DIMENSIONS AND DETERMINE DAYLIGHT OPENING SIZES TO
ENSURE SQUARENESS. OUT OF SQUARE CONDITIONS MAY
REQUIRE ADDITIONAL MEASUREMENT ALLOWANCES FOR
THE NEW WINDOW UNIT.
ALL EXISTING METAL MATERIALS MUST BE ISOLATED FROM
NEW CORROSIVE PRODUCTS USING NONCONDUCTIVE
COATINGS, MEMBRANES OR SEALANTS.
ALL FASTENERS MUST BE CORROSIVE RESISTANT. 3"
STAINLESS STEEL FASTENERS ARE TO BE USED. FASTEN
HEAD AND JAMBS A MAXIMUM OF 18" O.C.
VERIFY ALL RETROFIT WINDOWS FIT WITHIN THE DAYLIGHT
OPENING AND FLUSH FINS WILL COVER THE EXTERIOR OF
THE PRE-EXISTING WINDOW'S FRAME. TRIM ALL
PROTRUDING ELEMENTS PART OF THE EXISTING WINDOW.
INSULATE ALL VOIDS WITH FIBERGLASS INSULATION. ALL
NEW WINDOW UNITS TO BE DOUBLE FLASHED. INSTALL JAMB
EXTENSIONS AS REQUIRED.
DO NOT ALLOW HEAD AND JAMBS TO BOW. ALLOW 1 1/4"
MINIMUM PENETRATION OF FASTENER INTO FRAMING. ALL
SHIMS USED WILL BE DRY TREATED WOOD OR SYNTHETIC.
INSTALL ALL NEW WINDOW UNITS LEVEL, PLUMB AND
SQUARE.
FOR SMALL WALL PATCHES AROUND WINDOW OPENING
(LESS THAN 100 IN²), USE APPROPRIATE GYPSUM BOARD
PATCHING METHODS.
PATCH AND REPAIR WALL SURFACE AROUND WINDOW
OPENING TO SEAMLESSLY MATCH THE ADJACENT EXISTING
SURFACES IN TERMS OF FINISH AND TEXTURE.
9. CONTRACTOR TO VERIFY THE EXISTING WINDOW FRAMES
WILL ALLOW FOR FULL PERIMETER CONTACT WITH THE
FLUSH FIN OF THE RETROFIT WINDOW. TRIM EXTERIOR FIN
OF RETROFIT WINDOW AS REQUIRED.
EXISTING ASSEMBLY TO REMAIN
NEW WINDOW COMPONENTS
5.
6.
7.
8.
9.
10.
11.
INSIDE OUTSIDE
CUT NAILING FIN OF EXISTING
WINDOW
INTERIOR GYPSUM BOARD TO
REMAIN, PATCH & REPAIR AS
REQUIRED
EXISTING THRU-WALL FLASHING
WITH WEEPS TO REMAIN
EXISTING SHEATHING TO REMAIN
EXISTING BRICK MANSORY TO
REMAIN
BLOCKING IS NECESSARY
TO PREVENT ROTATION OF NEW
WINDOW SILL
FLUSH FLANGE
REPLACEMENT WINDOW
EXISTING BRICK MANSORY
BEYOND TO REMAIN
EXISTING WOOD TRIM
BEYOND TO REMAIN
SEALANT
INSIDE TRIM
WINDOW SCREEN
INSIDE OUTSIDE
INTERIOR GYPSUM BOARD TO
REMAIN, PATCH & REPAIR AS
REQUIRED
EXISTING THRU-WALL FLASHING
WITH WEEPS TO REMAIN
EXISTING SHEATHING TO REMAIN
EXISTING STONE MANSORY VENEER
TO REMAIN
BLOCKING AS NECESSARY
TO PREVENT ROTATION OF NEW
WINDOW SILL
FLUSH FLANGE
REPLACEMENT WINDOW
EXISTING STONE MANSORY
VENEER BEYOND TO REMAIN
EXISTING WOOD TRIM TO REMAIN
SEALANT
INSIDE TRIM
WINDOW SCREEN
INSIDE OUTSIDE
INTERIOR GYPSUM BOARD TO
REMAIN, PATCH & REPAIR AS
REQUIRED
EXISTING SHEATHING TO REMAIN
BLOCKING AS NECESSARY
TO PREVENT ROTATION OF NEW
WINDOW SILL
FLUSH FLANGE
REPLACEMENT
WINDOW
EXISTING WOOD TRIM TO REMAIN
SEALANT
INSIDE TRIM
WINDOW SCREEN
EXISTING CONTINUOUS DRIP
FLASHING AT HEAD, BACK SEALED
TO FLASHING
INSIDE OUTSIDE
EXISTING SHEATHING TO REMAIN
EXISTING AIR/MOISTURE BARRIER
MEMBRANE ON SHEATHING TO
REMAIN
SEALANT
FLANGE FLUSH
REPLACEMENT
WINNDOW
INTERIOR GYPSUM BOARD
TO REMAIN, PATCH & REPAIR
AS REQUIRED
BLOCKING AS NECESSARY
TO PREVENT ROTATION OF NEW
WINDOW SILL
INSIDE TRIM
WINDOW SCREEN
EXISTNG WOOD TRIM
TO REMAIN
INSIDE
OUTSIDE
INTERIOR GYPSUM BOARD TO
REMAIN, PATCH & REPAIR AS
REQUIRED
EXISTING SHEATHING TO REMAIN
EXISTING SIDING TO REMAIN
EXISTING AIR/MOISTURE BARRIER
MEMBRANE ON SHEATHING TO
REMAIN
EXISTING WOOD TRIM TO REMAIN
3 1 /2"
0'
- 3 7/2
0'
- 4 9/2
INSIDE TRIM
SEALANT
FLUSH FLANGE
REPLACEMENT WINDOW
BLOCKING AS NECESSARY
TO PREVENT ROTATION OF NEW
WINDOW SILL
WINDOW SCREEN
DURAND-HOLLIS RUPE
ARCHITECTS, INC.
14603 HUEBNER RD.
BUILDING 18
SAN ANTONIO, TEXAS 78230
PHONE: 210/308-0080
FAX: 210/697-3309
eMAIL: office@dhrarchitects.com
THIS DRAWING IS PROVIDED AS AN INSTRUMENT
OF SERVICE BY THE ARCHITECT AND IS INTENDED
FOR USE ON THIS PROJECT ONLY. THE DRAWING
REMAINS THE PROPERTY OF THE ARCHITECT AND
SHALL BE RETURNED TO HIM/HER UPON THE
COMPLETION OF THE CONSTRUCTION WORK.
PERSUANT TO THE ARCHITECTURAL WORKS
COPYRIGHT PROTECTION ACT OF 1990, ALL
DRAWINGS, SPECIFICATIONS, IDEAS AND
DESIGNS, INCLUDING THE OVERALL FORM,
ARRANGEMENT AND COMPOSITION OF SPACES
AND ELEMENTS APPEARING HEREIN, CONSTITUTES
THE COPYRIGHTED WORK OF THE ARCHITECT.
ANY REPRODUCTION, USE, OR DISCLOSURE OF
INFORMATION CONTAINED HEREIN WITHOUT
PRIOR WRITTEN CONSENT OF THE ARCHITECT IS
STRICTLY PROHIBITED.
© 2025
SHEET NO.:
ARCHITECT:
GABRIEL DURAND-HOLLIS, FAIA
LICENSE NUMBER: TX 10881
RO
O
FI
N G A N D W
IN
DO
W R
EP
LA
C
EM
EN
T
O
PP
O
RT
UN
ITY
H O M E
SA
N A N
TO
N
IO
HI
G
HV
IE
W A
PA
RT
M
EN
TS
L
IN
DA
L O U A
PA
RT
M
EN
TS
HIGHVIEW APARTMENTS
WINDOW REPLACEMENT
DETAILS
PROJECT No. : 25-005
ISSUE DATE: 12/11/25
DRAWN BY: DHR
REVIEWED BY: DHR
A107
R
IG
SB
Y A V E, S A N A N
TO
N
IO
, T X
S H A C
KB
ER
RY
S T, S A N A N
TO
N
IO
, T X
6" = 1'-0"5 VINYL WNDOW SILL - BRICK CONDITION
6" = 1'-0"4 VINYL WINDOW SILL - STONE VENEER CONDITION
6" = 1'-0"3 VINYL WINDOW SILL - SIDING CONDITION
6" = 1'-0"1 VINYL WINDOW HEAD - SIDING CONDITION
6" = 1'-0"2 VINYL WINDOW JAMB - SIDING CONDITION
LINDA LOU DR LINDA LOU DR
B O
XE
LD
ER
L N
B O
XE
LD
ER
L N
S H A C K B
ER
R Y
ST
S H A C K B
ER
R Y
ST
BLDG. 102BLDG. 124
EXISTING GAS
AND ELECTRICAL
METERS
EXISTING POWER
POLE
EXISTING FIRE
HYDRANT
EXISTING FIRE
HYDRANT
EXISTING POWER
POLE
EXISTING POWER
POLE
EXISTING FENCING
TO REMAIN
EXISTING FENCING
TO REMAIN
EXISTING FENCING
TO REMAIN
EXISTING FENCING
TO REMAIN
EXISTING TRASH
ENCLOSURE FENCE
AND DUMPSTERS
PARKING
PARKING
EXISTING FENCING
TO REMAIN
EXISTING RAMP
EXISTING ELECTRICAL
METER
DS
DS
GENERAL NOTES
1. CONSTRUCTION DOCUMENTS: THIS SET OF CONSTRUCTION DOCUMENTS IS PRESENTED TO INCLUDE DRAWINGS AND A SET OF SPECIFICATIONS ON 24" x 36" SHEETS. THIS SET OF CONSTRUCTION
DOCUMENTS INDICATES THE GENERAL DESIGN INTENT, AND MAY NOT DESCRIBE ALL WORK
REQUIRED FOR FULL PERFOMANCE AND COMPLETION. THE CONTRACTOR SHALL PROVIDE ALL
ITEMS REQUIRED FOR A COMPLETE AND OPERATIONAL PROJECT. ALL OF THE CONTRACT
DOCUMENTS (ARCHITECTURAL) ARE TO BE USED TOGETHER. THE GENERAL CONTRACTOR AND ALL
SUBCONTRACTORS ARE TO REVIEW COMPLETE SETS OF DOCUMENTS AND REPORT ANY
DISCREPANCIES TO THE ARCHITECT IMMEDIATELY. SHOULD ANY QUESTIONS ARISE PRIOR TO THE
BEGINNING OF CONSTRUCTION OR DURING CONSTRUCTION, THE CONTRACTOR SHALL
IMMEDIATELY NOTIFY THE ARCHITECT FOR REVIEW AND CLARIFICATION BEFORE PROCEEDING
WITH THAT PORTION OF THE WORK OR ANY PART RELATED THERETO.
2. EXISTING CONDITIONS: THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND
DIMENSIONS AT THE JOB SITE BEFORE COMMENCING WORK. REPORT, IMMEDIATELY, ANY NOTED DISCREPANCIES TO THE ARCHITECT. THE CONTRACTOR SHALL FAMILIARIZE HIM (HER) SELF WITH
EXISTING CONDITIONS BEFORE COMMENCING WORK, INCLUDING, BUT NOT LIMITED TO
EXISTENCE AND LOCATION OF ASBESTOS, OR OTHER UNKNOWN TOXIC MATERIALS.
3. PROTECTION: CONTRACTOR SHALL PROTECT ALL EXISTING SITE IMPROVEMENTS AND ADJACENT PROPERTY THAT IS SCHEDULED TO REMAIN. CONTRACTOR IS LIABLE FOR ANY DAMAGES TO THE
EXISTING IMPROVEMENTS. CONTRACTOR SHALL CONFINE OPERATIONS TO THE DESIGNATED
CONSTRUCTION AREAS SO AS NOT TO DISRUPT BUILDING TENANTS OR TO MINIMIZE
INTERRUPTIONS.
4.…
This is the start of the file's text. The full file is on GovTribe.