6-90257389 Linda Lou Apt. Renovations - Asbestos LCP Survey Report (WCD 10-28-25).pdf

PDF 4 MB Posted

Attached to
Highview & Linda Lou Apartments Roofing and Window Replacement
Solicitation number
2602-5657
Issued by
Bexar County, Texas

About this file

This is a Limited Asbestos and Lead-Containing Paint (LCP) Survey Report prepared by Terracon Consultants, Inc. for Opportunity Home San Antonio (formerly San Antonio Housing Authority) regarding the Linda Lou Apartment complex located at 4603 S. Hackberry Street in San Antonio, Texas. The survey was conducted on October 3rd and October 8th, 2025, with the report finalized on October 29, 2025 (Project Number 90257389). The assessment evaluated all 10 units, HVAC closets, and the laundry room for the presence of asbestos-containing materials (ACM) and lead-based/containing paint materials in anticipation of planned renovations. Field activities included visual assessment, physical assessment, sample collection, and laboratory analysis in accordance with EPA regulations 40 CFR 763 (AHERA) and 40 CFR 61 (NESHAP), Texas Environmental Lead Reduction Rules (TELRR), and Texas Department of State Health Services regulations. A total of 54 bulk asbestos samples were collected from 12 homogeneous areas, and 181 XRF readings plus 7 bulk paint chip samples were collected for lead content analysis.

The survey identified multiple materials containing asbestos, including drywall construction (walls and ceilings) containing 2-3% Chrysotile classified as RACM (Regulatory Asbestos-Containing Material) spanning approximately 26,000 square feet, resilient floor tile with black mastic containing 3% Chrysotile (6,000 SF), cement asbestos pipe containing 15% Chrysotile (25 SF), and exterior caulking containing 2% Chrysotile (2,500 linear feet). Regarding lead-containing paint, XRF analysis identified light blue paint on exterior overhangs, walkways, door frames, and HVAC closet walls exceeding the 1.0 mg/cm² standard established by TDSHS, EPA, and HUD. Laboratory analysis of seven bulk paint samples revealed one sample of green paint on exterior window shades containing 2,800 ppm lead, while six samples tested below the detection limit. The grouted ceramic tile in bathroom shower/tub areas was also identified as containing lead-based components with readings exceeding 1.0 mg/cm².

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

6000 Northwest Parkway, Suite 100

San Antonio, Texas 78249

P (210) 641-2112

F (210) 641-2124

Limited Asbestos and

Lead-Containing Paint

Survey Report

Linda Lou Apartment Renovations

4603 S. Hackberry Street

San Antonio, Texas 78223

October 29, 2025 | Project Number: 90257389

Prepared for:

Opportunity Home San Antonio

818 South Flores

San Antonio, Texas 78204

6000 Northwest Parkway, Suite 100

San Antonio, Texas 78249

P (210) 641-2112

F (210) 641-2124

Terracon.com

Facilities | Environmental | Geotechnical | Materials

October 29, 2025

Opportunity Home San Antonio

818 South Flores

San Antonio, TX 78204

Attn: Lucretia Robinson | Senior Administrative Specialist

P: (210) 740-8208

E: lucretia_robinson@homesa.org

Re: Limited Asbestos and Lead-Containing Paint Survey Report

Linda Lou Apartment Renovations

4603 S Hackberry Street

San Antonio, Texas 78223

Terracon Project No. 90257389

Ms. Robinson:

Terracon Consultants, Inc. (Terracon) is pleased to submit this limited asbestos and lead-containing paint (LCP) survey report to Opportunity Home San Antonio (Client).

We appreciate the confidence you placed in us on this project and look forward to working with you on future projects. Please contact the undersigned if you have questions about this report.

Respectfully submitted, Terracon Consultants, Inc.

Carlos M. Campos

Field Work

Asbestos Inspector/Lead Risk Assessor

TDSHS License/Certification Nos. 603746/2071187

Will C. DeVeau

Report Review

Asbestos Individual Consultant

TDSHS License No. 105734

Damian T. Busby

Field Work/Report Preparation

Asbestos Inspector/Lead Risk Assessor

TDSHS License/Certification Nos. 604265/2071366

Damian Busby

Carlos Campos Will DeVeau mailto:lucretia_robinson@homesa.org

Limited Asbestos and Lead-Containing Paint Survey Report

Linda Lou Apartment Renovations | San Antonio, Texas

October 29, 2025 | Terracon Project No. 90257389

Facilities | Environmental | Geotechnical | Materials

TABLE OF CONTENTS

1.1 Project Objective

1.2 Limitations

3.1 Visual Assessment

3.2 Physical Assessment

3.3 Sample Collection

3.4 Sample Analysis

3.5 Lead-Based Paint Methodology and Analysis

3.6 Lead-Based Paint Wall and Component Indetification System

3.7 XRF Instrumentation

4.1 Findings

4.2 Recommendations

Appendices

Appendix A Asbestos Survey Sample Summary

Appendix B Lead-Containing Paint Survey Sample Summary

Appendix C Lead-Based Paint XRF Analytical Report

Appendix D XRF Performance Characteristics Sheet

Appendix E Sample Location Drawings

Appendix F Regulatory Overview

Appendix G Asbestos Laboratory Analytical Report

Appendix H Lead Laboratory Analytical Report

Appendix I Licenses & Certifications

Facilities | Environmental | Geotechnical | Materials 1

INTRODUCTION

Terracon Consultants, Inc. (Terracon) conducted a limited asbestos and LCP survey of the

Survey Area as defined in Section 2.0 in general accordance with Terracon Proposal No.

P90257389 dated July 22, 2025 and the Master Services Agreement (2103-925-35-5110-

5198) dated November 9, 2021, and Schedule #75 dated September 16, 2025 authorized by

Opportunity Home San Antonio (Client).

◼ Prior survey reports were not provided to Terracon for review.

1.1 Project Objective

The objective of the limited asbestos and LCP survey was to identify the presence and location of accessible friable and nonfriable asbestos-containing materials (ACM) and lead-based/containing paint materials present in the survey area, collect samples, and report our findings. This survey was requested by the Client prior to renovation of the Survey Area defined below.

1.2 Limitations

The scope of the survey was limited to the Survey Area indicated in Section 2.0, at the request of Client. The interior, exterior, and roof were included in the survey. Destructive sampling was not conducted as indicated in Terracon’s proposal (excluding roof sampling).

BUILDING AND SURVEY AREA DESCRIPTION

Survey Area The survey area included interior/exterior/roof areas, as applicable, of all

10 units, HVAC Closets, and Laundry Room of the Linda Lou Apartments.

Structure Use Apartment Housing.

Typical Interior Walls Textured drywall construction and grouted ceramic tile.

Typical Interior Ceilings Textured drywall construction.

Typical Interior Floors Adhered resilient floor tile and grouted ceramic tile.

Additional Information Asphalt shingle roofs on apartment buildings and the HVAC Closets.

FIELD ACTIVITIES

Terracon conducted the limited asbestos and LCP survey in general accordance with protocols established in Environmental Protection Agency (EPA) regulation 40 Code of Federal

Regulations (CFR) 763 the Asbestos Hazard Emergency Response Act (AHERA), EPA regulation 40 CFR 61 the National Emission Standard for Hazardous Air Pollutants (NESHAP), Texas Environmental Lead Reduction Rules (TELRR) guidelines, and the Texas Department of

State Health Services (TDSHS) regulations promulgated under the Texas Asbestos Health

Protection Rules (TAHPR).

Facilities | Environmental | Geotechnical | Materials 2

An X-Ray Fluorescence (XRF) type analyzer was used to obtain direct readouts of lead content in coated surfaces associated with all 10 units, HVAC Closets, and Laundry Room of the Linda

Lou Apartment complex. XRF values are read and recorded in the field. Where XRF analyses resulted in readings below the standard set by TDSHS, EPA, and the Department of Housing and Urban Development (HUD) of 1.0 mg/cm2, or exceptionally high concentrations of lead, the sample team randomly selected locations for collection of bulk paint chip samples for laboratory confirmation. The following sections present a summary of our survey activities.

3.1 Visual Assessment

Our survey activities began with visual observation in the survey area(s) to identify homogeneous areas of suspect ACM. A homogeneous area (HA) consists of building materials that appear similar throughout in terms of color, texture, and date of application. Building materials identified as glass, wood, masonry, metal, or rubber were not considered suspect

ACM. The assessment was conducted throughout visually accessible portions of the survey area(s).

Suspect materials located behind mirrors, brick, or within wall cavities were not sampled in order to prevent excessive damage to the material. Suspect materials, such as vermiculite fill, mastic, or other materials (i.e., overspray texturizers) which were not accessible on the day of the survey should be sampled prior to demolition activities if the activities will disturb the materials. Destructive sampling to assess moisture barrier materials within the building envelope of the apartment buildings, HVAC Closets, and Laundry Room was not included in the current scope of work (SOW).

Terracon visually assessed interior and exterior areas (including roof) of all 10 units, HVAC

Closets, and Laundry Room of the Linda Lou Apartment complex to identify painted/coated surfaces with suspect lead-containing paint (LCP). Painted/coated surfaces which appear similar throughout in terms of color, texture, substrate, and date of application are treated as a homogeneous paint combination for paint chip collection purposes. Painted/coated surfaces were visually assessed for evidence of distress, flaking, chipping and/or peeling. The visual assessment included evaluating the condition of the building, condition of painted surfaces, dust accumulation in interior spaces, and painted components at impact or friction surfaces. The information gathered in the visual assessment was utilized in determining the collection points of LCP samples collected.

The LCP sampling was limited to readily observable and accessible surfaces. It should be noted that suspect LCP, other than those identified during the sampling, may exist within the interior and exterior areas of the units, HVAC Closets, and Laundry Room. Materials which have not been specifically evaluated should be tested prior to disturbance of the material. If suspect LCP is identified during the demolition process, those materials should be assumed

LCP until testing can be performed to determine if lead is present in the paint.

Facilities | Environmental | Geotechnical | Materials 3

3.2 Physical Assessment

Terracon conducted a physical assessment of each identified HA of suspect ACM to assess the friability and condition of the materials. EPA defines a friable material as a material which, when dry, can be crumbled, pulverized, or reduced to powder by hand pressure. Terracon assessed friability by physically touching suspect ACM.

Additionally, Terracon conducted a physical assessment of each painted/coated surface to assess its condition. The painted/coated surfaces were assessed to be in intact or deteriorated condition depending on degree of cracking, flaking, chipping and/or peeling.

3.3 Sample Collection

Based on results of the visual observation, Terracon collected random bulk samples from each identified HA of suspect ACM observed in general accordance with AHERA sampling protocols.

Sample team members collected bulk samples using wet methods as applicable to reduce the potential for fiber release. Samples were placed in sealable containers and labeled with unique sample numbers using indelible ink.

Additionally, bulk chip samples of suspect paint materials were collected in general accordance with the TELRR and HUD Guidelines. Each bulk chip sample was placed in sealable containers and labeled with unique sample numbers using indelible ink.

3.4 Sample Analysis

Terracon delivered bulk asbestos samples under chain-of-custody (COC) to a laboratory that is accredited by the National Voluntary Laboratory Accreditation Program (NVLAP) for analysis by Polarized Light Microscopy (PLM) with dispersion staining techniques per EPA Method

600/R-93/116. The percentage of asbestos where applicable was determined by microscopic visual estimation.

Bulk samples of suspect LCP were submitted under COC to a laboratory that is accredited by the American Industrial Hygiene Association Laboratory Accreditation Programs, LLC (AIHA

LAP) (Laboratory ID: LAP-100420) and the Texas Commission on Environmental Quality

(TCEQ) (Certificate ID: TX-C24-00406) for analysis by Atomic Absorption Spectrometry (AAS) flame methodology.

3.5 LBP Methodology and Analysis

A SciAps X-550 XRF instrument was used to determine whether surface coatings contained lead-based paint (LBP). All 10 units, HVAC Closets, and the Laundry Room were evaluated to identify different testing combinations present. For the purposes of this survey and in the absence of published guidelines for testing commercial buildings, Terracon generally observed the HUD Guidelines for testing housing; per these guidelines, individual tests are to be classified as part of a group based on the testing combination (room equivalent, component, and substrate). Substrates are classified as brick, masonry, concrete, drywall, metal, plaster, or

Facilities | Environmental | Geotechnical | Materials 4 wood. A component is defined as an item, such as doors, windows, walls, etc. When using testing combinations, LBP results are classified by summing the individual component test results of positive, negative, or inconclusive.

For more detailed information, including testing location, component, color, and substrate, refer to the LBP XRF analytical report contained in Appendix C.

No materials were assumed to be LBP. Any inaccessible areas that contain painted surfaces should be tested when access permits or should be assumed to be positive for LBP.

3.6 LBP Wall and Component Identification

Wall sides were identified with letters A, B, C and D. Side A is the north side. Sides B, C, and

D are identified clockwise, starting from the “3 o’clock" position from Side A as one faces north;

thus, Side B is to the right, Side C is across from Side A, and Side D is to the left of Side A.

3.7 XRF Instrumentation

The SciAps X-550 XRF (Serial No. 1586) was used in the testing for LBP for this project. During the inspection, the standard set by the TDSHS, EPA and HUD of 1.0 mg/cm2 was followed to determine the components that contained LBP.

The calibration of the SciAps X-550 XRF was done in accordance with the Performance

Characteristic Sheet (PCS). The SciAps X-550 XRF was calibrated using the paint film nearest

1.0 mg/cm2 in the National Institute of Standards and Technology (NIST) Standard Reference

Material (SRM).

Using protocols provided by the HUD and instrument manufacturer and in accordance with the

NIST reference standard, calibration checks are performed at least twice daily, once prior to the inspection and once immediately after the inspection. If for any reason the SciAps X-550 XRF is not maintaining a consistent calibration reading within the manufacturer’s standards for performance on the calibration sheet supplied by the manufacturer, manufacturer’s recommendations are used to bring the instrument into calibration. If the instrument cannot be brought back into calibration, the instrument will be returned to the manufacturer for repair and/or recalibration. The PCS is located in Appendix D.

An XRF reading above the standard of 1.0 mg/cm2 of lead is considered positive for the presence of LBP; however, while a reading below 1.0 mg/cm2 is considered negative for the presence of

LBP, disturbance of the material could still create harmful conditions if proper precautions are not taken during activities that disturb these paint combinations.

Facilities | Environmental | Geotechnical | Materials 5

FINDINGS AND RECOMMENDATIONS

4.1 Findings

Terracon conducted the limited asbestos and LCP survey on October 3rd and October 8th, 2025.

The following personnel participated in the field work during the survey:

◼ Mr. Carlos M. Campos a licensed Asbestos Inspector/Lead Risk Assessor (TDSHS

License/Certification Nos. 603746/2071187)

◼ Mr. Damian T. Busby a licensed Asbestos Inspector/Lead Risk Assessor (TDSHS

License/Certification Nos. 604265/2071366)

A summary of bulk asbestos and bulk paint chip samples collected is presented in Appendices

A and B. The LBP XRF Analytical Report is included in Appendix C. The sample location drawing is provided in Appendix E. The Regulatory Overview is provided in Appendix F. The Asbestos

Laboratory Analytical Report is included in Appendix G. The Lead Laboratory Analytical Report is included in Appendix H. Licenses and Certifications are provided in Appendix I.

Terracon’s findings provided below are based upon laboratory results and field observations:

Fifty-four (54) bulk asbestos samples were collected from 12 homogeneous areas of suspect

ACM.

Materials Reported to Contain Asbestos

Sample

ID

Material

Material

Location

Asbestos

Content Friability

Assessed

Condition

Estimated

Quantity

Apartment Buildings

H-01, 02, 03, 04, 05, 06, 07, 08, 09, Drywall Construction

– White with an

Orange Peel Texture

Utilized as the walls throughout the Units, HVAC

Closets, and Laundry Room

(except the Laundry Room HVAC Closet)

2%

Chrysotile RACM Good 20,000 SF

H-11, 12, 13, 14, 15, 16, 17, 18, 19, Drywall Construction

– White with an

Orange Peel Texture

Utilized as the ceiling throughout the

Units, HVAC

Closets, and the

Laundry Room

(except the

Laundry Room

HVAC Closet)

2-3%

Chrysotile RACM Good 6,000 SF

Facilities | Environmental | Geotechnical | Materials 6

Materials Reported to Contain Asbestos

Sample

ID

Material

Material

Location

Asbestos

Content Friability

Assessed

Condition

Estimated

Quantity

H-21, 22, 23, 24, 25

Resilient Floor Tile –

1’ x 1’, Multi-Colored with Tan Mastic Over

Multi-Colored 1’ x 1’

Resilient Floor Tile with Tan/Black Mastic

(2 Layers)

Utilized on the floor throughout the Units

No

Asbestos

Detected in

Top Floor

Tile or Tan

Mastic

No

Asbestos

Detected in

Bottom

Floor Tile

3%

Chrysotile in Black

Mastic

Category I

Nonfriable Good 6,000 SF

H-34, 35, 36

Cement Asbestos Pipe

– White

Utilized on the piping on the water heaters throughout HVAC

Closets 2, 3, 4, 7, 8, and 9

15%

Chrysotile

Category II

Nonfriable Good 25 SF

H-46, 47, 48

Exterior Caulking –

White

Utilized around the exterior windows, doors, and top portion of the buildings

2%

Chrysotile

Category I

Nonfriable Good

2,500 Linear

Feet

None of the other suspect building materials sampled and analyzed were found to contain asbestos.

One-hundred eighty-one (181) XRF readings were collected along with 16 calibration readings for a total of 197 readings as part of this study.

Analysis using the XRF unit indicated that one (1) paint testing combination exceeded the unit’s analytical detection of 1.0 mg/cm2 and is considered “Lead-

Based” by HUD:

◼ Readings 164-174, 177-185, & 187-193 – The light blue paint material applied to the exterior overhang of the walkways, door/door frames to units, walls of the HVAC

Closets/Laundry Room, and portions of the east and west walls of both buildings was found to contain 0 – 1.19 mg/cm2 lead. Where observed, this material was found to be in intact condition.

Facilities | Environmental | Geotechnical | Materials 7

In addition, analysis using the XRF unit indicated that the grouted ceramic tile on the walls of the shower/tub in the Bathrooms in the majority of units throughout the complex are lead-containing components (LCC) as the readings exceed 1.0 mg/cm2 lead.

Where XRF analysis resulted in readings below the standard set by the TDSHS, EPA, and the

HUD of 1.0 mg/cm2, or exceptionally high concentrations of lead, the sample team randomly selected locations for collection of bulk paint chip samples for laboratory confirmation.

Seven (7) bulk chip samples of suspect paint materials were collected in general accordance with the TELRR and HUD Guidelines. Each bulk chip sample was placed in a sealable container and labeled with a unique sample number using an indelible marker.

One (1) of the 7 paint/coatings bulk sampled and analyzed by a laboratory as part of this survey were found to contain detectable quantities of lead (above detection but below 5,000 ppm) rendering them LCP and be considered a potential hazard by the

Occupational Safety and Health Administration (OSHA):

Exterior:

◼ L-L06 – The green paint material applied to exterior window shades on the north side of Building 1 was found to contain 2800 ppm lead. Where observed, this material was found to be in intact condition.

Six (6) of the 7 paint/coatings bulk sampled and analyzed by a laboratory as part of this survey was found to contain lead in concentrations below the limit of detection (LOD) and would be considered by OSHA to present no workforce hazard:

Apartment Buildings:

◼ L-L01 – The off-white paint material applied to the walls and ceilings throughout select

Units, HVAC Closets, and Laundry Room; and the doors/doorframes throughout the

HVAC Closets was found to contain <44 ppm lead. Where observed, this material was found to be in intact condition.

◼ L-L02 – The white paint material applied to the door/door frames, window frames/sills, and baseboards throughout select Units was found to contain <44 ppm lead. Where observed, this material was found to be in intact condition.

◼ L-L03 – The light brown paint material applied to the door/door frames throughout the

Laundry Room was found to contain <50 ppm lead. Where observed, this material was found to be in intact condition.

Facilities | Environmental | Geotechnical | Materials 8

◼ L-L04 – The blue paint material applied to the east and west walls in the Unit 101

(Building 2) Bathroom was found to contain <39 ppm lead. Where observed, this material was found to be in intact condition.

Exterior:

◼ L-L05 – The yellow paint material applied to the exterior soffits on the east and west sides of Buildings 1 and 2 was found to contain <50 ppm lead. Where observed, this material was found to be in intact condition.

◼ L-L07 – The gray paint material applied to the exterior facades, columns, wall edge trim, and gutters on both buildings; and the door/door frames to HVAC Closets was found to contain <43 ppm lead. Where observed, this material was found to be in intact condition.

4.2 Recommendations

Based upon our findings, Terracon makes the following recommendations (refer to the

Regulatory Overview in Appendix F for additional information):

Asbestos:

1. Abatement of interior ACM that will be disturbed during renovation activities must be performed by a State of Texas licensed asbestos contractor in accordance with a project design prepared by a State of Texas licensed asbestos consultant. In addition, third party air monitoring must be performed during the abatement by a licensed asbestos consultant.

2. It is important to note that the NESHAP and the State of Texas require written notification be submitted before beginning renovation projects that include the disturbance of certain quantities of ACM in a building or facility, or before the demolition of a building or facility, even when no asbestos is present. This written notification must be provided to the TDSHS, the state governing agency, at least 10 working days prior to the commencement of asbestos abatement or demolition activities.

3. Excluded, inaccessible, or new materials that were not sampled during this survey must be inspected and sampled prior to disturbing those materials, or those materials must be assumed to be ACM. If the analysis determines that the new material contains asbestos and could potentially be disturbed during renovation or demolition activities, then proper abatement of the material will be required. Additionally, prior to disturbing the material it must be removed, transported, and disposed by properly trained/licensed personnel.

Facilities | Environmental | Geotechnical | Materials 9

Lead:

1. In areas where the Client does not intend to renovate or demolish the buildings currently on-site, the LCP/LBP/LCC materials, which will remain in the buildings, should be managed in place. It is recommended that this in-place management should include such operations as stabilizing or repairing any damaged materials, protecting the remaining LCP/LBP/LCC materials from further damage, and developing a plan to periodically monitor the condition of the LCP/LBP/LCC materials. Notification of the presence of the materials should also be made to employees and outside contractors so that they do not inadvertently disturb the remaining LCP/LBP/LCC materials.

2. Where project plans would disturb the LCP/LBP/LCC materials associated with the buildings currently on-site, it is recommended that contracting personnel who may disturb the materials associated with the buildings be made aware of the lead content in the materials so that they may exercise proper OSHA procedures for personnel protection or possibly employ protective procedures when working with the coatings.

3. Planned renovation activities impacting those materials determined to contain measurable concentrations of lead will be subject to OSHA regulations (29 CFR

1926.62 – Lead Exposure in Construction). The OSHA regulation defines specific training requirements, engineering controls, and working practices for construction personnel subject to this standard. There are also federal and state regulations, which require characterization of demolition debris to determine the proper disposal procedures.

4. Construction work covered by 29 CFR 1926.62 includes any repair, renovation, or other activities that disturb in-place, LBP/LCP materials, but does not include routine cleaning and repainting where there is insignificant damage, wear, or corrosion of existing LBP/LCP or substrates. Employers must assure that no employee will be exposed to lead at concentrations greater than the PEL of 50 g/m3 averaged over an

8-hour period without adequate protection. The OSHA standard also establishes an action level (AL) of 30 g/m3, which if exceeded, triggers certain requirements, including periodic exposure monitoring and medical monitoring.

5. Terracon recommends personnel air sampling of workers that perform work on surfaces with LCP/LBP/LCC materials. Personnel sampling should be performed in compliance with OSHA regulations. It is recommended that contracting personnel who may disturb the LCP/LBP/LCC materials associated with the buildings currently on-site be made aware of the lead content in the materials so that they may exercise proper

OSHA procedures for personnel protection or possibly employ protective procedures when working with the coatings.

6. Compliance with applicable OSHA lead regulations is the responsibility of the contractor performing the work and it is recommended that they be required to communicate potential lead hazards to their workforce and utilize lead-safe work practices such as outlined in the EPA Renovation, Repair, and Painting (RRP) Final Rule (40 CFR 745) or applicable portions of the Structural Steel Painting Council (SSPC) Guidelines. It is

Facilities | Environmental | Geotechnical | Materials 10 further recommended that activities such as flame/torch dismantling, dry sanding and/or dry grinding of any components with LBP/LCP materials applied should be prohibited as part of any repair, renovation, or demolition activity.

7. It is recommended that any painted metal components which are to be removed from the buildings currently on-site be segregated from the waste stream and be transferred to a suitable metal recycling facility.

8. As the buildings currently on-site are Target Housing, the HUD and TDSHS lead regulations apply to removal operations associated with the buildings.

9. The EPA Resource Conservation and Recovery Act (RCRA) regulations set the limit of leachable lead in lead containing waste at 5.0 milligrams per liter (mg/L). Leachable lead means the amount of lead likely to leach from the waste into the surrounding soil of a landfill. This level is established by an analytical method called the Toxicity

Characteristic Leaching Procedure (TCLP). Lead-containing waste that equals or exceeds the RCRA limit must be managed in accordance with RCRA regulations. This regulation affects the disposal of demolition or remodel debris containing lead or LBP.

GENERAL COMMENTS

Terracon conducted this limited asbestos and LCP survey in a manner consistent with the level of care and skill ordinarily exercised by members of the profession currently practicing under similar conditions in the same locale. The results, findings, conclusions, and recommendations expressed in this report are based on conditions observed during our survey. The information contained in this report is relevant to the dates on which this survey was conducted and should not be relied upon to represent conditions later.

This report has been prepared on behalf of and exclusively for use by Client for specific application to their project. This report is not a bidding document. Contractors, consultants, or others reviewing this report must draw their own conclusions regarding further investigation or remediation deemed necessary. Terracon does not warrant the work of regulatory agencies, laboratories, or other third parties supplying information which may have been used in the preparation of this report. No warranty, express or implied, is made.

October 29, 2025 | Terracon Project No. 90257389

Facilities | Environmental | Geotechnical | Materials

APPENDIX A

ASBESTOS SURVEY SAMPLE SUMMARY

October 29, 2025 | Terracon Project No. 90257389

Facilities | Environmental | Geotechnical | Materials

APPENDIX A – ASBESTOS SURVEY SAMPLE SUMMARY

Sample

ID

Material Material Location

Asbestos Containing

Apartment Buildings

H-01, 02, 03, 04, 05, 06, 07, 08, 09, 10

Drywall Construction – White with an Orange Peel Texture

Utilized as the walls throughout the Units, HVAC Closets, and Laundry Room (except the

Laundry Room HVAC Closet)

Yes

H-11, 12, 13, 14, 15, 16, 17, 18, 19, 20

Drywall Construction – White with an Orange Peel Texture

Utilized as the ceilings throughout the Units, HVAC Closets, and Laundry Room (except the Laundry Room

HVAC Closet)

Yes

H-21, 22, 23, 24, 25

Resilient Floor Tile – 1’ x 1’, Multi- Colored with Yellow Mastic Over

Multi-Colored 1’ x 1’ Resilient Floor Tile with Black Mastic (2 Layers)

Utilized on the floor throughout the Units

Yes

H-26, 27, 28, 29, 30

Ceramic Wall Tile Grout & Mortar – White/Gray

Utilized between/behind the ceramic tile on the walls of the showers throughout the Units

No

H-31, 32, Cove Base – Multi-Colored with Tan Mastic

Utilized on the base of walls throughout the HVAC Closets, south wall of Building 2, Unit 104 (Kitchen), and Building 2, Unit

106(Bathroom)

No

H-34, 35, Fibrous Cementitious Pipe (FRP) – White

Utilized on the piping on the water heaters throughout HVAC

Closets 2, 3, 4, 7, 8, and 9 Yes

H-37, 38, Ceramic Floor Tile Grout & Mortar – Black/Gray

Utilized between/beneath the ceramic tile flooring throughout

Building 2 and Unit 106(Bathroom) No

H-40, 41, Sink Undercoating - White Utilized as the undercoating beneath the sink in Building 2, and Unit 106 (Kitchen Sink)

Yes

H-43, 44, Drywall Construction – Tape Only Utilized as the walls throughout the

Laundry Room HVAC Closet throughout

No

Exterior

H-46, 47, Exterior Caulking – White

Utilized on the exterior windows, doors, and top portion of the buildings where the brick meets the overhang

Yes

October 29, 2025 | Terracon Project No. 90257389

Facilities | Environmental | Geotechnical | Materials

APPENDIX A – ASBESTOS SURVEY SAMPLE SUMMARY

Sample

ID

Material Material Location

Asbestos Containing

H-49, 50, Exterior Plaster – Gray Utilized on the base of exterior walls throughout Building 1 and 2 No

H-52, 53, Asphalt Shingle Roof – Black Utilized as the field-of-roof of the apartment buildings throughout the complex

No

October 29, 2025 | Terracon Project No. 90257389

Facilities | Environmental | Geotechnical | Materials

APPENDIX B

LEAD-CONTAINING PAINT SAMPLE SUMMARY

October 29, 2025 | Terracon Project No. 90257389

Facilities | Environmental | Geotechnical | Materials

APPENDIX B – LEAD-CONTAINING PAINT SURVEY SAMPLE SUMMARY

Sample

ID

Combination Substrate Functional Area Conditio n Lead

Content

Apartment Buildings

L-L01 Off-White Drywall

Construction

(DWC)

Applied to the walls and ceilings throughout select Units, HVAC Closets, and Laundry Room; and the doors/doorframes throughout the

HVAC Closets

Intact <44 ppm

L-L02 White Wood

Applied to the walls, ceilings, door/door frames, window frames/sills, baseboards, and cabinets throughout select Units and Outside Storages

Intact <44 ppm

L-L03 Light Brown Wood Applied to the door/door frames throughout the Laundry Room

Intact <50 ppm

L-L04 Blue DWC Applied to the east and west walls in

Unit 101 Bathroom Intact <39 ppm

Exterior

L-L05 Yellow Wood Applied to the exterior soffits on the east and west sides of Buildings 1 and

Intact <50 ppm

L-L06 Green Wood Applied to exterior window shades on the north side of Building 1 Intact

2,800 ppm

L-L07 Gray Metal & Wood

Applied to the exterior facades, columns, wall edge trim, and gutters on both buildings; and the door/door frames to HVAC Closets

Intact <43 ppm

Readings 164-174, 177-185, & 187-193

Light Blue Wood

Applied to the exterior overhang of the walkways, door/door frames to units, walls of the HVAC Closets/Laundry Room, and portions of the east and west walls of both buildings

Intact 0 to 1.19 mg/cm² ppm: parts per million

October 29, 2025 | Terracon Project No. 90257389

Facilities | Environmental | Geotechnical | Materials

APPENDIX C

LEAD-BASED PAINT XRF ANALYTICAL REPORT

Date Test # Pass/Fail Calibration Model/Matrix ID Pb Pb P/F Project # Substrate Wall Condition Color Calibration Interior/Exterior Building Component Notes 10/8/2025 1 Pass PCS Cal 1.1 Positive 90257389 Calibration 10/8/2025 2 Pass PCS Cal 1.12 Positive 90257389 Calibration 10/8/2025 3 Pass PCS Cal 1.14 Positive 90257389 Calibration 10/8/2025 4 Pass PCS Cal 1.12 Positive 90257389 Calibration 10/8/2025 5 LeadPaint 0 Negative 90257389 Drywall A Intact Off-White Interior Linda Lou Apartments Wall Building 2, Unit 106 - Living Room 10/8/2025 6 LeadPaint 0 Negative 90257389 Drywall B Intact Off-White Interior Linda Lou Apartments Wall Building 2, Unit 106 - Kitchen 10/8/2025 7 LeadPaint 0 Negative 90257389 Drywall C Intact Off-White Interior Linda Lou Apartments Wall Building 2, Unit 106 - Bathroom 10/8/2025 8 LeadPaint 0 Negative 90257389 Drywall D Intact Off-White Interior Linda Lou Apartments Wall Building 2, Unit 106 - Bedroom 10/8/2025 9 LeadPaint 0 Negative 90257389 Wood Intact Off-White Interior Linda Lou Apartments Baseboard Building 2, Unit 106 - Bedroom 10/8/2025 10 LeadPaint 0 Negative 90257389 Wood Intact Off-White Interior Linda Lou Apartments Door Building 2, Unit 106 - Bathroom 10/8/2025 11 LeadPaint 0 Negative 90257389 Wood Intact Off-White Interior Linda Lou Apartments Door Frame Building 2, Unit 106 - Living Room 10/8/2025 12 LeadPaint 0 Negative 90257389 Wood Intact Off-White Interior Linda Lou Apartments Window Frame Building 2, Unit 106 - Living Room 10/8/2025 13 LeadPaint 0 Negative 90257389 Wood Intact White Interior Linda Lou Apartments Window Sill Building 2, Unit 106 - Kitchen 10/8/2025 14 LeadPaint 0 Negative 90257389 Wood Intact Off-White Interior Linda Lou Apartments Cabinet Building 2, Unit 106 - Kitchen 10/8/2025 15 LeadPaint 0 Negative 90257389 Drywall Intact Off-White Interior Linda Lou Apartments Ceiling Building 2, Unit 106 - Kitchen 10/8/2025 16 LeadPaint 0 Negative 90257389 Ceramic Tile A Intact Off-White Interior Linda Lou Apartments Wall Building 2, Unit 106 - Bathroom Shower/Tub 10/8/2025 17 LeadPaint 0 Negative 90257389 Ceramic Tile C Intact Yellow Interior Linda Lou Apartments Wall Building 2, Unit 106 - Bathroom Shower/Tub 10/8/2025 18 LeadPaint 0 Negative 90257389 Ceramic Tile Intact Beige Interior Linda Lou Apartments Floor Building 2, Unit 106 - Bathroom 10/8/2025 19 LeadPaint 0 Negative 90257389 Drywall A Intact Off-White Interior Linda Lou Apartments Wall HVAC Closet 5 10/8/2025 20 LeadPaint 0 Negative 90257389 Drywall B Intact Off-White Interior Linda Lou Apartments Wall HVAC Closet 6 10/8/2025 21 LeadPaint 0 Negative 90257389 Drywall C Intact Off-White Interior Linda Lou Apartments Wall HVAC Closet 7 10/8/2025 22 LeadPaint 0 Negative 90257389 Drywall D Intact Off-White Interior Linda Lou Apartments Wall HVAC Closet 8 10/8/2025 23 LeadPaint 0 Negative 90257389 Drywall Intact Off-White Interior Linda Lou Apartments Ceiling HVAC Closet 9 10/8/2025 24 LeadPaint 0 Negative 90257389 Drywall Intact Off-White Interior Linda Lou Apartments Ceiling Laundry Room 10/8/2025 25 LeadPaint 0 Negative 90257389 Wood Intact Off-White Interior Linda Lou Apartments Door Frame HVAC Closet 6 10/8/2025 26 LeadPaint 0.21 Negative 90257389 Wood Intact Off-White Interior Linda Lou Apartments Door HVAC Closet 8 10/8/2025 27 LeadPaint 0 Negative 90257389 Wood Intact Light Brown Interior Linda Lou Apartments Door Laundry Room 10/8/2025 28 LeadPaint 0 Negative 90257389 Wood Intact Light Brown Interior Linda Lou Apartments Door Laundry Room 10/8/2025 29 LeadPaint 0 Negative 90257389 Wood Intact Light Brown Interior Linda Lou Apartments Door Frame Laundry Room 10/8/2025 30 LeadPaint 0 Negative 90257389 Wood Intact Light Brown Interior Linda Lou Apartments Door Frame Laundry Room 10/8/2025 31 LeadPaint 0 Negative 90257389 Drywall A Intact Off-White Interior Linda Lou Apartments Wall Building 2, Unit 105 - Living Room 10/8/2025 32 LeadPaint 0 Negative 90257389 Drywall B Intact Off-White Interior Linda Lou Apartments Wall Building 2, Unit 105 - Kitchen 10/8/2025 33 LeadPaint 0 Negative 90257389 Drywall C Intact Off-White Interior Linda Lou Apartments Wall Building 2, Unit 105 - Bedroom 10/8/2025 34 LeadPaint 0 Negative 90257389 Drywall D Intact Off-White Interior Linda Lou Apartments Wall Building 2, Unit 105 - Bathroom 10/8/2025 35 LeadPaint 0 Negative 90257389 Drywall Intact Off-White Interior Linda Lou Apartments Ceiling Building 2, Unit 105 - Closet 10/8/2025 36 LeadPaint 0.26 Negative 90257389 Drywall Intact Off-White Interior Linda Lou Apartments Door Building 2, Unit 105 - Closet 10/8/2025 37 LeadPaint 0 Negative 90257389 Drywall Intact Off-White Interior Linda Lou Apartments Door Frame Building 2, Unit 105 - Bathroom 10/8/2025 38 LeadPaint 0 Negative 90257389 Wood Intact Tan Interior Linda Lou Apartments Window Frame Building 2, Unit 105 - Bedroom 10/8/2025 39 LeadPaint 0 Negative 90257389 Wood Intact White Interior Linda Lou Apartments Window Sill Building 2, Unit 105 - Bedroom 10/8/2025 40 LeadPaint 0 Negative 90257389 Wood Intact White Interior Linda Lou Apartments Baseboard Building 2, Unit 105 - Bedroom 10/8/2025 41 LeadPaint 1.14 Positive 90257389 Ceramic Tile A Intact White Interior Linda Lou Apartments Wall Building 2, Unit 105 - Bathroom Shower/Tub 10/8/2025 42 LeadPaint 1.15 Positive 90257389 Ceramic Tile D Intact White Interior Linda Lou Apartments Wall Building 2, Unit 105 - Bathroom Shower/Tub 10/8/2025 43 LeadPaint 0 Negative 90257389 Drywall A Intact Off-White Interior Linda Lou Apartments Wall Building 2, Unit 101 - Living Room 10/8/2025 44 LeadPaint 0 Negative 90257389 Drywall B Intact Off-White Interior Linda Lou Apartments Wall Building 2, Unit 101 - Kitchen 10/8/2025 45 LeadPaint 0 Negative 90257389 Drywall C Intact Off-White Interior Linda Lou Apartments Wall Building 2, Unit 101 - Bedroom 10/8/2025 46 LeadPaint 0 Negative 90257389 Drywall D Intact Off-White Interior Linda Lou Apartments Wall Building 2, Unit 101 - Closet 10/8/2025 47 LeadPaint 0 Negative 90257389 Drywall Intact Off-White Interior Linda Lou Apartments Ceiling Building 2, Unit 101 - Bathroom 10/8/2025 48 LeadPaint 0 Negative 90257389 Wood Intact Off-White Interior Linda Lou Apartments Door Building 2, Unit 101 - Bathroom

SciAps X-550 Lead-Based Paint XRF Analytical Report

Inspection Date: 10/8/2025 Inspection Site:

Linda Lou Apartment Renovations

4603 S. Hackberry Street

San Antonio, Texas 78223

Project Number: 90257389

Total Readings: 197

Unit Started: 10/8/2025

Unit Ended: 10/8/2025

Date Test # Pass/Fail Calibration Model/Matrix ID Pb Pb P/F Project # Substrate Wall Condition Color Calibration Interior/Exterior Building Component Notes

SciAps X-550 Lead-Based Paint XRF Analytical Report

Inspection Date: 10/8/2025 Inspection Site:

Linda Lou Apartment Renovations

4603 S. Hackberry Street

San Antonio, Texas 78223

Project Number: 90257389

Total Readings: 197

Unit Started: 10/8/2025

Unit Ended: 10/8/2025

10/8/2025 49 LeadPaint 0.13 Negative 90257389 Wood Intact Off-White Interior Linda Lou Apartments Door Frame Building 2, Unit 101 - Bedroom 10/8/2025 50 LeadPaint 0 Negative 90257389 Wood Intact Off-White Interior Linda Lou Apartments Baseboard Building 2, Unit 101 - Living Room 10/8/2025 51 LeadPaint 0 Negative 90257389 Wood Intact Off-White Interior Linda Lou Apartments Window Sill Building 2, Unit 101 - Kitchen 10/8/2025 52 LeadPaint 0 Negative 90257389 Drywall B Intact Blue Interior Linda Lou Apartments Wall Building 2, Unit 101 - Bedroom 10/8/2025 53 LeadPaint 0 Negative 90257389 Drywall D Intact Blue Interior Linda Lou Apartments Wall Building 2, Unit 101 - Bedroom 10/8/2025 54 LeadPaint 0 Negative 90257389 Ceramic Tile C Intact Beige Interior Linda Lou Apartments Wall Building 2, Unit 101 - Bathroom Shower/Tub 10/8/2025 55 LeadPaint 0 Negative 90257389 Drywall A Intact Off-White Interior Linda Lou Apartments Wall Building 2, Unit 104 - Living Room 10/8/2025 56 LeadPaint 0 Negative 90257389 Drywall B Intact Off-White Interior Linda Lou Apartments Wall Building 2, Unit 104 - Kitchen 10/8/2025 57 LeadPaint 0 Negative 90257389 Drywall C Intact Off-White Interior Linda Lou Apartments Wall Building 2, Unit 104 - Bedroom 10/8/2025 58 LeadPaint 0 Negative 90257389 Drywall D Intact Off-White Interior Linda Lou Apartments Wall Building 2, Unit 104 - Bathroom 10/8/2025 59 LeadPaint 0 Negative 90257389 Drywall Intact Off-White Interior Linda Lou Apartments Ceiling Building 2, Unit 104 - Closet 10/8/2025 60 LeadPaint 0.25 Negative 90257389 Wood Intact White Interior Linda Lou Apartments Door Building 2, Unit 104 - Closet 10/8/2025 61 LeadPaint 0.1 Negative 90257389 Wood Intact White Interior Linda Lou Apartments Door Frame Building 2, Unit 104 - Bedroom 10/8/2025 62 LeadPaint 0 Negative 90257389 Wood Intact White Interior Linda Lou Apartments Baseboard Building 2, Unit 104 - Bedroom 10/8/2025 63 LeadPaint 0 Negative 90257389 Wood Intact White Interior Linda Lou Apartments Window Sill Building 2, Unit 104 - Living Room 10/8/2025 64 LeadPaint 0 Negative 90257389 Wood Intact White Interior Linda Lou Apartments Window Frame Building 2, Unit 104 - Living Room 10/8/2025 65 LeadPaint 0.01 Negative 90257389 Ceramic Tile C Intact Gray Interior Linda Lou Apartments Wall Building 2, Unit 104 - Bathroom Shower/Tub 10/8/2025 66 LeadPaint 0 Negative 90257389 Wood Intact White Interior Linda Lou Apartments Cabinet Building 2, Unit 104 - Kitchen 10/8/2025 67 LeadPaint 0 Negative 90257389 Drywall A Intact Off-White Interior Linda Lou Apartments Wall Building 1, Unit 104 - Living Room 10/8/2025 68 LeadPaint 0 Negative 90257389 Drywall B Intact Off-White Interior Linda Lou Apartments Wall Building 1, Unit 104 - Kitchen 10/8/2025 69 LeadPaint 0 Negative 90257389 Drywall C Intact Off-White Interior Linda Lou Apartments Wall Building 1, Unit 104 - Bedroom 10/8/2025 70 LeadPaint 0 Negative 90257389 Drywall D Intact Off-White Interior Linda Lou Apartments Wall Building 1, Unit 104 - Bathroom 10/8/2025 71 LeadPaint 0 Negative 90257389 Drywall Intact Off-White Interior Linda Lou Apartments Ceiling Building 1, Unit 104 - Closet 10/8/2025 72 LeadPaint 0.01 Negative 90257389 Wood Intact White Interior Linda Lou Apartments Door Building 1, Unit 104 - Closet 10/8/2025 73 LeadPaint 0.11 Negative 90257389 Wood Intact White Interior Linda Lou Apartments Door Frame Building 1, Unit 104 - Bathroom 10/8/2025 74 LeadPaint 0 Negative 90257389 Wood Intact White Interior Linda Lou Apartments Window Frame Building 1, Unit 104 - Bedroom 10/8/2025 75 LeadPaint 0 Negative 90257389 Wood Intact White Interior Linda Lou Apartments Window Sill Building 1, Unit 104 - Bedroom 10/8/2025 76 LeadPaint 0 Negative 90257389 Wood Intact White Interior Linda Lou Apartments Baseboard Building 1, Unit 104 - Living Room 10/8/2025 77 LeadPaint 0 Negative 90257389 Wood Intact White Interior Linda Lou Apartments Cabinet Building 1, Unit 104 - Kitchen 10/8/2025 78 LeadPaint 7.4 Positive 90257389 Ceramic Tile B Intact Beige Interior Linda Lou Apartments Wall Building 1, Unit 104 - Bathroom Shower/Tub 10/8/2025 79 LeadPaint 7.53 Positive 90257389 Ceramic Tile C Intact Beige Interior Linda Lou Apartments Wall Building 1, Unit 104 - Bathroom Shower/Tub 10/8/2025 80 LeadPaint 0 Negative 90257389 Drywall A Intact Off-White Interior Linda Lou Apartments Wall Building 1, Unit 103 - Living Room 10/8/2025 81 LeadPaint 0 Negative 90257389 Drywall B Intact Off-White Interior Linda Lou Apartments Wall Building 1, Unit 103 - Kitchen 10/8/2025 82 LeadPaint 0 Negative 90257389 Drywall C Intact Off-White Interior Linda Lou Apartments Wall Building 1, Unit 103 - Bedroom 10/8/2025 83 LeadPaint 0 Negative 90257389 Drywall D Intact Off-White Interior Linda Lou Apartments Wall Building 1, Unit 103 - Closet 10/8/2025 84 LeadPaint 0 Negative 90257389 Drywall Intact Off-White Interior Linda Lou Apartments Ceiling Building 1, Unit 103 - Bathroom 10/8/2025 85 LeadPaint 0 Negative 90257389 Wood Intact White Interior Linda Lou Apartments Baseboard Building 1, Unit 103 - Bathroom 10/8/2025 86 LeadPaint 0.27 Negative 90257389 Wood Intact White Interior Linda Lou Apartments Door Frame Building 1, Unit 103 - Closet 10/8/2025 87 LeadPaint 0 Negative 90257389 Wood Intact White Interior Linda Lou Apartments Window Frame Building 1, Unit 103 - Bedroom 10/8/2025 88 LeadPaint 0 Negative 90257389 Wood Intact White Interior Linda Lou Apartments Window Sill Building 1, Unit 103 - Bedroom 10/8/2025 89 LeadPaint 0 Negative 90257389 Wood Intact White Interior Linda Lou Apartments Door Building 1, Unit 103 - Living Room 10/8/2025 90 LeadPaint 0 Negative 90257389 Wood Intact White Interior Linda Lou Apartments Cabinet Building 1, Unit 103 - Kitchen 10/8/2025 91 LeadPaint 7.84 Positive 90257389 Ceramic Tile D Intact Beige Interior Linda Lou Apartments Wall Building 1, Unit 103 - Bathroom Shower/Tub 10/8/2025 92 LeadPaint 7.35 Positive 90257389 Ceramic Tile B Intact Beige Interior Linda Lou Apartments Wall Building 1, Unit 103 - Bathroom Shower/Tub 10/8/2025 93 LeadPaint 0 Negative 90257389 Drywall A Intact Off-White Interior Linda Lou Apartments Wall Building 1, Unit 102 - Living Room 10/8/2025 94 LeadPaint 0 Negative 90257389 Drywall B Intact Blue Interior Linda Lou Apartments Wall Building 1, Unit 102 - Living Room 10/8/2025 95 LeadPaint 0 Negative 90257389 Drywall C Intact Off-White Interior Linda Lou Apartments Wall Building 1, Unit 102 - Living Room 10/8/2025 96 LeadPaint 0 Negative 90257389 Drywall D Intact Off-White Interior Linda Lou Apartments Wall Building 1, Unit 102 - Kitchen

Date Test # Pass/Fail Calibration Model/Matrix ID Pb Pb P/F Project # Substrate Wall Condition Color Calibration Interior/Exterior Building Component Notes

Inspection Date: 10/8/2025 Inspection Site:

Linda Lou Apartment Renovations

4603 S. Hackberry Street

San Antonio, Texas 78223

Project Number: 90257389

Total Readings: 197

Unit Started: 10/8/2025

Unit Ended: 10/8/2025

10/8/2025 97 LeadPaint 0 Negative 90257389 Drywall Intact Off-White Interior Linda Lou Apartments Ceiling Building 1, Unit 102 - Kitchen 10/8/2025 98 LeadPaint 0 Negative 90257389 Wood Intact White Interior Linda Lou Apartments Baseboard Building 1, Unit 102 - Kitchen 10/8/2025 99 LeadPaint 0 Negative 90257389 Wood Intact White Interior Linda Lou Apartments Window Frame Building 1, Unit 102 - Living Room 10/8/2025 100 LeadPaint 0 Negative 90257389 Wood Intact White Interior Linda Lou Apartments Window Sill Building 1, Unit 102 - Living Room 10/8/2025 101 LeadPaint 0.2 Negative 90257389 Wood Intact White Interior Linda Lou Apartments Door Frame Building 1, Unit 102 - Living Room 10/8/2025 102 LeadPaint 0 Negative 90257389 Wood Intact White Interior Linda Lou Apartments Door Building 1, Unit 102 - Living Room 10/8/2025 103 LeadPaint 7.69 Positive 90257389 Ceramic Tile C Intact Beige Interior Linda Lou Apartments Wall Building 1, Unit 102 - Bathroom Shower/Tub 10/8/2025 104 LeadPaint 0 Negative 90257389 Drywall A Intact Off-White Interior Linda Lou Apartments Wall Building 1, Unit 101 - Living Room 10/8/2025 105 LeadPaint 0 Negative 90257389 Drywall B Intact Off-White Interior Linda Lou Apartments Wall Building 1, Unit 101 - Kitchen 10/8/2025 106 LeadPaint 0 Negative 90257389 Drywall C Intact Off-White Interior Linda Lou Apartments Wall Building 1, Unit 101 - Bedroom 10/8/2025 107 LeadPaint 0.01 Negative 90257389 Drywall D Intact Off-White Interior Linda Lou Apartments Wall Building 1, Unit 101 - Bathroom 10/8/2025 108 LeadPaint 0 Negative 90257389 Drywall Intact Off-White Interior Linda Lou Apartments Ceiling Building 1, Unit 101 - Bathroom 10/8/2025 109 LeadPaint 0 Negative 90257389 Wood Intact White Interior Linda Lou Apartments Baseboard Building 1, Unit 101 - Bathroom 10/8/2025 110 LeadPaint 0 Negative 90257389 Wood Intact White Interior Linda Lou Apartments Cabinet Building 1, Unit 101 - Bedroom 10/8/2025 111 LeadPaint 0.2 Negative 90257389 Wood Intact White Interior Linda Lou Apartments Door Frame Building 1, Unit 101 - Closet 10/8/2025 112 LeadPaint 0 Negative 90257389 Wood Intact White Interior Linda Lou Apartments Door Building 1, Unit 101 - Bedroom 10/8/2025 113 LeadPaint 0 Negative 90257389 Wood Intact White Interior Linda Lou Apartments Window Frame Building 1, Unit 101 - Living Room 10/8/2025 114 LeadPaint 0 Negative 90257389 Wood Intact White Interior Linda Lou Apartments Window Sill Building 1, Unit 101 - Living Room 10/8/2025 115 LeadPaint 0 Negative 90257389 Ceramic Tile B Intact White Interior Linda Lou Apartments Wall Building 1, Unit 101 - Bathroom Shower/Tub 10/8/2025 116 LeadPaint 0 Negative 90257389 Drywall A Intact White Interior Linda Lou Apartments Wall HVAC Closet 1 10/8/2025 117 LeadPaint 0 Negative 90257389 Drywall B Intact White Interior Linda Lou Apartments Wall HVAC Closet 2 10/8/2025 118 LeadPaint 0 Negative 90257389 Drywall C Intact Off-White Interior Linda Lou Apartments Wall HVAC Closet 3 10/8/2025 119 LeadPaint 0 Negative 90257389 Drywall D Intact Off-White Interior Linda Lou Apartments Wall HVAC Closet 4 10/8/2025 120 LeadPaint 0 Negative 90257389 Drywall Intact Off-White Interior Linda Lou Apartments Ceiling HVAC Closet 4 10/8/2025 121 LeadPaint 0 Negative 90257389 Wood Intact Off-White Interior Linda Lou Apartments Door HVAC Closet 4 10/8/2025 122 LeadPaint 0 Negative 90257389 Wood Intact Off-White Interior Linda Lou Apartments Door Frame HVAC Closet 2 10/8/2025 123 Pass PCS Cal 1.08 Positive 90257389 Calibration 10/8/2025 124 Pass PCS Cal 1.13 Positive 90257389 Calibration 10/8/2025 125 Pass PCS Cal 1.1 Positive 90257389 Calibration 10/8/2025 126 Pass PCS Cal 1.1 Positive 90257389 Calibration 10/8/2025 127 Pass PCS Cal 1.16 Positive 90257389 Calibration 10/8/2025 128 Pass PCS Cal 1.08 Positive 90257389 Calibration 10/8/2025 129 Pass PCS Cal 1.1 Positive 90257389 Calibration 10/8/2025 130 Pass PCS Cal 1.11 Positive 90257389 Calibration 10/8/2025 131 LeadPaint 0.1 Negative 90257389 Wood Intact Gray Exterior Linda Lou Apartments Facade Building 2 10/8/2025 132 LeadPaint 0.42 Negative 90257389 Wood Intact Gray Exterior Linda Lou Apartments Facade Building 2 10/8/2025 133 LeadPaint 0.72 Negative 90257389 Wood Intact Gray Exterior Linda Lou Apartments Facade Building 2 10/8/2025 134 LeadPaint 0 Negative 90257389 Metal Intact Gray Exterior Linda Lou Apartments Gutter Building 2 10/8/2025 135 LeadPaint 0.02 Negative 90257389 Metal Intact Gray Exterior Linda Lou Apartments Column Building 2 10/8/2025 136 LeadPaint 0 Negative 90257389 Metal Intact Gray Exterior Linda Lou Apartments Screen Door Building 2 - Unit 10/8/2025 137 LeadPaint 0 Negative 90257389 Wood Intact Gray Exterior Linda Lou Apartments Door Building 2 - Laundry Room 10/8/2025 138 LeadPaint 0.58 Negative 90257389 Wood Intact Gray Exterior Linda Lou Apartments Door Frame Building 2 - HVAC Closets 10/8/2025 139 LeadPaint 0 Negative 90257389 Wood Intact Gray Exterior Linda Lou Apartments Door Frame Building 2 - HVAC Closets 10/8/2025 140 LeadPaint 0.41 Negative 90257389 Wood Intact Gray Exterior Linda Lou Apartments Door…