8 Fence Material specs.doc
DOC document 50 KB Posted
- Attached to
- PFO JAMES RYEGRASS ALLOTMENT FENCE
- Solicitation number
- 140L6220Q0107
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Sol_140L6220Q0107_Amd_0001.pdf | ||
| 6 02829 End Stress Panels and 3 Post Corners.doc | DOC document | |
| 9 James Ryegrass Project 2018 75K.pdf | ||
| Sol_140L6220Q0107.pdf | ||
| 3 01009 general.docx | DOCX document | |
| 7 Work Data Sheet.docx | DOCX document | |
| 5 02827 fence removal.docx | DOCX document | |
| 2 Bid Schedule.doc | DOC document | |
| 11 James Ryegrass Fence Drawings.pdf | ||
| 10 James Ryegrass Project 2018 24K Map.pdf | ||
| 4 02825 wood fences and gates.docx | DOCX document |
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Material Specifications:
Specifications
A. Barbed Wire: A strand of two 12‑1/2‑gauge galvanized wires twisted together with 2‑point barbs of 14‑gauge wire spaced 4-inches apart. Wire and barbs shall be zinc‑coated steel, with a zinc coating of at least 0.3 oz/ft2 of coated surface area. The minimum breaking strength of each wire shall be 950 lb‑force. The barbed wire shall conform to ASTM A 121.
B.
Barbless Wire: A strand of two 12‑1/2‑gauge galvanized wires twisted together. Wire shall be zinc‑coated steel wire of at least 0.3 oz/ft2 of coated surface area. The minimum breaking strength of each wire shall be 950 lb‑force. The barbless wire shall conform to ASTM A 12 C.
Wood Posts and Braces:
1.
Acceptable Wood Posts: Sound single-stem members. A slight bend in one plane is acceptable. Posts may be full stem members, sawed members of square cross section, or split members (western red cedar only). Nominal diameter for treated posts shall be 5-inches or 6-inches. The following species will be acceptable: Ponderosa pine, Lodgepole pine, fir, and tamarack. All treated posts shall be free of bark with ends cut square.
2.
Basis for Rejection: Posts are not acceptable when sweep causes a straight line joining the center of the top to the center of the butt to fall outside the body of the post, or at point 2-inches or more from the center of the post. Posts that are charred, twisted, rotted, or excessively bent are not acceptable. Seasoning checks, single or opposite each other with a sum total equal to or more than 1/2 the thickness of the post are not acceptable.
3. Wood Treatment Practices: General: The following treatments may be used for treatment method shall be in accordance with AWPA C 1.
a) Chromated Copper Arsenic Method: Chromated copper arsenate, waterborne preservative (conforming to Type B in AWPA 5) shall be applied. Minimum net retention of solid preservative shall be 0.4 pounds per cubic foot (gauge only) using the full-cell pressure treatment process.
b) Assay Report: The Supplier shall furnish an assay report, for all treated wood products, from an independent testing laboratory to the Contracting Officer. A minimum of five inch boring shall be taken from each bundle of 50 posts as samples for the assay report.
A written submittal for all materials shall be submitted for approval to Andy Skordas (askordas@blm.gov) and Megan Vasquez Ogle (mvasquezogle@blm.gov) at Rawlins Wyoming BLM Field Office prior to shipping the products.
Contact Andy Skordas at 307-320-5714, or Megan Vasquez Ogle at 307-320-5713 with any questions.