This is a Questions and Answers document for solicitation 75H71525R00001 regarding the WiFi network installation at the Monacan Health Center facility. The document clarifies technical requirements and specifications for the project.
Key requirements include: replacing originally specified Cisco C9300-48P-E with a Cisco C9800-L-C-K9 Catalyst 9800-L 802.11ax Wireless LAN Controller or equivalent to meet FIPS PUB 140-3 requirements; implementation of a local (not cloud-based) WLC; ceiling-mounted enclosures for indoor access points; implementation of IEEE 802.1X access control with vendor-provided licensing; installation of CAT6A red UTP cabling and 3' or less red patch cables; full building WiFi coverage with cables terminating at the main server room/MDF; optional outdoor AP for parking lot triage (required only if building signal doesn't extend 100' from front door); VLAN implementation (firewall not required); and compliance with IHS and DHHS security standards. The installation will utilize plenum space with cable trays or hooks provided by the vendor, with no conduit required. No existing management platform integration is needed as this is a new facility installation.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 75H71525R00001_Amd_0002.pdf | ||
| 75H71525R00001_Amd_0001.pdf | ||
| Attachment 1 - Floor Plan.pdf | ||
| 75H71525R00001.pdf | ||
| Attachment 2 - IHS IEE Form.pdf | ||
| Attachment 3 - WD 2015-4311.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1. Section E(1) on Page 4 of the solicitation should be a Cisco C9800 or equivalent to meet the FIPS PUB 140-3 requirement. The equipment listed in the top block of the graphic on Page 4 (Part Number: C9300-48P-E / Description: Catalyst 9300 48-port PoE+, Network Essentials) shall be replaced with a Cisco C9800-L-C-K9 Catalyst 9800-L 802.11ax Wireless Lan Controller or equivalent.
2. "Turnkey WiFi Network, which includes a switch, firewall, and access points" o Is there a WLC located at the Nashville Area Office that will be used for the requested
WiFi Network?
Answer: No, the Cisco C9800-L-C-K9 Catalyst 9800-L 802.11ax Wireless Lan Controller will be the controller at the site.
o Do you want a Local or Cloud-Based WLC?
Answer: The WLC shall be local.
3. Clarification:
o All runs must terminate at the main server room.
4. "Must be compliant with Indian Health Service (IHS) and the Department of Health and Human Services (DHHS) requirements."
The quoted requirements documentation refers to the FIPS PUB 140-1, 140-2, and 140-3 which are available from the NIST website. The security standards are listed throughout the requirements section of the SOW portion of the solicitation that cover the defining instruction of the cited documents listed below.
o IHS DIS SOP-09-36 - Wireless Network Security Standards o IHS CIO Memo, 8/24/2004 o Department of Health and Human Services (DHHS) requirements
5. "APs should be contained within enclosures or in physically secure locations to reduce the risk of unauthorized physical access or tampering" o Does the government prefer wall or ceiling-mounted enclosures for any indoor access points?
Answer: Ceiling mount enclosures are preferred for the additional tamper resistance factor of height.
6. "WLANs that are not configured for open/public access must implement IEEE 802.1X access control to prevent access from unauthorized WLAN devices" o Is it the contractor's responsibility to implement an 802.1X solution (new or existing) at this facility?
Answer: Yes, it is the vendor’s responsibility to implement the solution at the facility as it will be new.
o If YES above: Is there an 802.1X solution in place, and does the government have enough licensing for this implementation?
Answer: The facility is new so there is no solution in place at this time. Licensing for this shall be provided by the vendor, to be included in your proposal.
o Is it the contractor’s responsibility to configure 802.1X on the requested WiFi network?
Answer: Yes, it is the vendor’s responsibility to configure while working in conjunction with the Network Operations System Center (NOSC) office.
7. Is the intention of this solicitation to cover the entire building with WiFi coverage?
Answer: Yes.
8. The solicitation requests one (1) switch and one (1) firewall:
Clarification – the firewall is not required.
o Where would the government prefer that equipment be installed?
Answer: MDF o Is it the government’s intention to have all cabling connected to Access Points run to that location?
Answer: Yes.
9. Is there an existing management platform that this solution will be integrated with?
Answer: No.
10. Is any conduit required at this facility for any required line pulls that support the Access Points?
Answer: No, lines will go through the plenum in cable tray where existing or hooks provided by the vendor.
11. What category of Unshielded Twisted Pair (UTP) wire is required at this facility?
Answer: CAT6A is preferred.
o What color of UTP is desired?
Answer: Red.
o What color of UTP patch cables are desired?
Answer: Red.
o What length of UTP patch cables are desired?
Answer: 3’ or less.
12. The solicitation requires an "AP for parking lot in the event we need to provide triage outdoors" o Is there an existing pathway in place for the cabling to support the outdoor AP?
Answer: No.
o If Core Drilling is required to support, what type of building materials?
(Concrete/Brick/Metal/Wood/…) Answer: If the buildings signal strength extends 100’ from the front door, an exterior point would not be required. If a point is required it can be mounted to wood/metal siding at ceiling height or higher.
13. Is a firewall or VLAN required?
o VLAN is required