B01 Attachment J01b - Details.pdf

PDF 855 KB Posted

Attached to
Zuni Quarters Sewer Improvement Project
Solicitation number
75H70126R00014
Issued by

About this file

This file contains technical construction details for a water and sewer utility infrastructure project prepared by the Department of Health and Human Services, Public Health Service, Indian Health Service, Albuquerque Area DSFC. The document presents standardized construction specifications and cross-sectional details for trench work and manhole installations.

The specifications detail typical trench section 1A requirements, including pipe bedding and haunching material conforming to unified soils classification standards (GW, GP, SW, or SP soils), tracer wire attachment at 20-foot intervals minimum on water mains, water service lines, and sewer force mains per technical provisions TP-04, TP-05, and TP-43. Initial backfill must be compacted to 85 percent of reference density minimum, with final backfill compacted to specifications. Warning tape must be placed 12 inches above pipe. The document specifies utility line markers (detail 1B) in blue for water mains (66 inches tall, marked "Caution Water Pipeline") and green for sewer mains (72 inches tall, marked "Caution Sewer Pipeline"), placed every 500 linear feet. Bollard details (1C) show 4-inch concrete-filled steel pipes painted yellow for surface protection. Manhole specifications include shallow manhole design (6A) with 4-foot-0-inch diameter opening, standard manhole construction (6B) with precast concrete sections and adjustment rings, and drop manhole with exterior drop design (6C) utilizing PVC pipe, combination wye and bend fittings, and concrete encasement. All designs incorporate waterstop gaskets, gravel bases, and minimum concrete thickness requirements varying by manhole diameter.

View the file

Other files

Show all 18

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TYPICAL TRENCH SECTION

NTS

1A

TYPICAL TRENCH SECTIONS

1A

AutoCAD SHX Text 90%%D

AutoCAD SHX Text NOTES: 1. SPECIAL IMPORTED BEDDING AND SPECIAL IMPORTED BEDDING AND HAUNCHING MATERIAL SHALL MEET THE CRITERIA OF THE UNIFIED SOILS CLASSIFICATION SYSTEM FOR GW, GP, SW OR SP SOILS. 2. ATTACH TRACER WIRE TO PIPE 3 TIMES ATTACH TRACER WIRE TO PIPE 3 TIMES PER 20' PIPE LENGTH, MINIMUM. 3. TRACER WIRE IS REQUIRED ON WATER TRACER WIRE IS REQUIRED ON WATER MAINS, WATER SERVICE LINES AND SEWER FORCE MAINS PER TP-04, TP-05 AND TP-43.

AutoCAD SHX Text

CONDITIONS REQUIRING SPECIAL EMBEDMENT MATERIAL

AutoCAD SHX Text

12" MAX.

AutoCAD SHX Text

PIPE O.D.

AutoCAD SHX Text

CONDITIONS NOT REQUIRING SPECIAL EMBEDMENT MATERIAL

AutoCAD SHX Text

FINAL BACKFILL COMPACTED AS PER SPECIFICATIONS

AutoCAD SHX Text

FINAL BACKFILL COMPACTED AS PER SPECIFICATIONS

AutoCAD SHX Text

HAUNCHING (PLACED BY HAND AND COMPACTED TO 95% MIN. OF REFERENCE DENSITY)

AutoCAD SHX Text

CONTROL OR POWER CABLES (IF ANY)

AutoCAD SHX Text

BEDDING (COMPACT TO 95% OF REFERENCE DENSITY)

AutoCAD SHX Text BOTTOM 1/4 OF PIPE TO BEAR ON UNDISTURBED BOTTOM; FREE OF ROCK; PIPE NOT TO BE SUPPORTED BY BELLS

AutoCAD SHX Text

CONTROL OR POWER CABLES (IF ANY)

AutoCAD SHX Text

TRACER WIRE

AutoCAD SHX Text

INITIAL BACKFILL COMPACT TO 85% MIN. OF REFERENCE OF REFERENCE DENSITY

AutoCAD SHX Text

WARNING TAPE 12" ABOVE PIPE

AutoCAD SHX Text

12" MAX.

AutoCAD SHX Text

12" MAX.

AutoCAD SHX Text

PIPE O.D.

AutoCAD SHX Text

12" MAX.

AutoCAD SHX Text

DETAIL NO.

AutoCAD SHX Text

FILE NAME:

AutoCAD SHX Text

DETAIL NAME:

AutoCAD SHX Text

IHS-STD-BLOCKS-2021

AutoCAD SHX Text

INDIAN HEALTH SERVICE

AutoCAD SHX Text

PUBLIC HEALTH SERVICE

AutoCAD SHX Text

DEPT. OF HEALTH & HUMAN SERVICES

AutoCAD SHX Text

ALBUQUERQUE AREA DSFC

UTILITY LINE MARKER DETAIL

BOLLARD DETAIL

NTS

1C

1B

UTILITY LINE MARKER DETAIL

BOLLARD DETAIL

1B, 1C

AutoCAD SHX Text

ANCHOR BARB

AutoCAD SHX Text

EXPLODED VIEW

AutoCAD SHX Text NOTE: 1. WATER MAIN MARKERS SHALL BE BLUE, 66" WATER MAIN MARKERS SHALL BE BLUE, 66" TALL, MARKED "CAUTION WATER PIPELINE" "CAUTION WATER PIPELINE" 2. SEWERMAIN & SEWER FORCE MAIN MARKERS SEWERMAIN & SEWER FORCE MAIN MARKERS SHALL BE GREEN, 72" TALL, MARKED "CAUTION SEWER PIPELINE" 3. MARKERS SHALL BE PLACED EVERY 500 L.F. MARKERS SHALL BE PLACED EVERY 500 L.F. ALONG THE SPAN OF UTILITY LINE.

AutoCAD SHX Text

UTILITY LINE MARKER

AutoCAD SHX Text

ANCHOR BARB

AutoCAD SHX Text

CARSONITE UTILITY MARKER WITH ANCHOR BARB, OR EQUAL

AutoCAD SHX Text 4" CONCRETE FILLED STEEL PIPE, PAINTED YELLOW WITH 2 COATS OF PAINT; PREPARE SURFACE IN ACCORDANCE WITH PAINT MANUFACTURER'S RECOMMENDATIONS

AutoCAD SHX Text

DETAIL NO.

AutoCAD SHX Text

FILE NAME:

AutoCAD SHX Text

DETAIL NAME:

AutoCAD SHX Text

IHS-STD-BLOCKS-2021

AutoCAD SHX Text

INDIAN HEALTH SERVICE

AutoCAD SHX Text

PUBLIC HEALTH SERVICE

AutoCAD SHX Text

DEPT. OF HEALTH & HUMAN SERVICES

SHALLOW MANHOLE

6A

PLAN VIEW

SHALLOW MANHOLE

6A

AutoCAD SHX Text

NOTE: MIN. DROP ACROSS MH SHALL BE 0.1'

AutoCAD SHX Text

PIPE

AutoCAD SHX Text

PIPE

AutoCAD SHX Text

WATERSTOP

AutoCAD SHX Text

ELEVATION PER PLANS

AutoCAD SHX Text

WATERSTOP

AutoCAD SHX Text

INVERT OUT

AutoCAD SHX Text

INVERT IN

AutoCAD SHX Text 6" MIN. THICKNESS FOR MANHOLES UP TO 48" IN DIAMETER, 8" MIN. THICKNESS FOR MANHOLES OVER 48" DIAMETER.

AutoCAD SHX Text NOTES: 1. WATERSTOP GASKET GROUTED INSIDE MANHOLE WALL REQUIRED FOR PIPE CONNECTIONS. WATERSTOP GASKET GROUTED INSIDE MANHOLE WALL REQUIRED FOR PIPE CONNECTIONS. 2. RING & COVER SHALL BE CENTERED ON THE SEWER LINE ON THE UPSTREAM SIDE OF THE MANHOLE. 3. IN NON-TRAFFIC AREAS:MANHOLE RIM RIM SHALL EXTEND APPROX. 6" ABOVE FINISHED SURFACE. IN NON-TRAFFIC AREAS:MANHOLE RIM RIM SHALL EXTEND APPROX. 6" ABOVE FINISHED SURFACE. 4. IN TRAFFIC AREAS: RIM SHALL BE FLUSH WITH FINISHED TRAFFIC WAY/ROADWAY SURFACE.IN TRAFFIC AREAS: RIM SHALL BE FLUSH WITH FINISHED TRAFFIC WAY/ROADWAY SURFACE.RIM SHALL BE FLUSH WITH FINISHED TRAFFIC WAY/ROADWAY SURFACE.

AutoCAD SHX Text

INVERT IN

AutoCAD SHX Text

INVERT OUT

AutoCAD SHX Text

ADJUSTMENT RING(S).

AutoCAD SHX Text

DETAIL NO.

AutoCAD SHX Text

FILE NAME:

AutoCAD SHX Text

DETAIL NAME:

AutoCAD SHX Text

IHS-STD-BLOCKS-2021

AutoCAD SHX Text

INDIAN HEALTH SERVICE

AutoCAD SHX Text

PUBLIC HEALTH SERVICE

AutoCAD SHX Text

DEPT. OF HEALTH & HUMAN SERVICES

PLAN VIEW BAR PLACEMENT

SECTION A-A

STANDARD MANHOLE

NTS

6B

B

B

SECTION B-B

A A

M A

N H

O L

E

M

A N

H O

L E

F

R A

M E

C

O V

E R

B

AutoCAD SHX Text NOTES: 1. WATERSTOP GASKET GROUTED INSIDE MANHOLE WATERSTOP GASKET GROUTED INSIDE MANHOLE WALL REQUIRED FOR PIPE CONNECTIONS. 2. CONE SHALL BE CENTERED ON THE SEWER LINE ON THE UPSTREAM SIDE OF THE MANHOLE.

AutoCAD SHX Text

CONCRETE (PRECAST OR CIP)

AutoCAD SHX Text

CONCRETE COLLAR

AutoCAD SHX Text

ADJUSTMENT COLLAR ( USE AT LEAST ONE IN TRAFFIC AREAS, BUT NOT MORE THAT 12")

AutoCAD SHX Text

PRECAST ECCENTRIC CONCRETE CONE

AutoCAD SHX Text

WATERTIGHT SEAL AT ALL JOINTS

AutoCAD SHX Text

5" MIN. PRECAST CONCRETE SECTIONS

AutoCAD SHX Text

PIPE INVERT ELEVATION (IE)

AutoCAD SHX Text

REINF. W/8 #4 PLACED AS SHOWN 2" COVER AT ENDS AND BOTTOM

AutoCAD SHX Text TWO COURSES OF ADJUSTMENT RINGS (A TOTAL OF 8") MAXIMUM IF REQUIRED FOR ADJUSTING TOP OF MANHOLE TO GRADE.

AutoCAD SHX Text

CONCRETE COLLAR SHALL BE PRECAST OR FORMED IN PLACE

AutoCAD SHX Text

GRADE

AutoCAD SHX Text

FOR REINFORCING BAR PLACEMENT REFER TO PLAN VIEW BAR PLACEMENT DETAIL THIS SHEET

AutoCAD SHX Text 6" DEPTH FOR MANHOLES UP TO 48" IN DIAMETER, 8" DEPTH FOR MANHOLES OVER 48" DIAMETER.

AutoCAD SHX Text

1"/FT. MIN 2"/FT MAX

AutoCAD SHX Text

FLOW

AutoCAD SHX Text

FLOW

AutoCAD SHX Text

DETAIL NO.

AutoCAD SHX Text

FILE NAME:

AutoCAD SHX Text

DETAIL NAME:

AutoCAD SHX Text

IHS-STD-BLOCKS-2021

AutoCAD SHX Text

INDIAN HEALTH SERVICE

AutoCAD SHX Text

PUBLIC HEALTH SERVICE

AutoCAD SHX Text

DEPT. OF HEALTH & HUMAN SERVICES

PLAN VIEW

DROP MANHOLE DETAIL - EXTERIOR DROP

NTS

6C

DROP MANHOLE

EXTERIOR DROP

6C

AutoCAD SHX Text

PVC PIPE

AutoCAD SHX Text

PVC PIPE

AutoCAD SHX Text

COMBINATION WYE AND BEND

AutoCAD SHX Text

TRENCH EXCAVATION PER OSHA REQUIREMENTS

AutoCAD SHX Text

PVC PIPE

AutoCAD SHX Text

WATERSTOP

AutoCAD SHX Text

COMBINATION WYE AND BEND (GASKETED)

AutoCAD SHX Text

CONCRETE ENCASEMENT FROM BOTTOM OF MH BASE TO 6" ABOVE ELBOW JOINT

AutoCAD SHX Text

PVC 90° GASKETEDELBOW

AutoCAD SHX Text

PVC PIPE

AutoCAD SHX Text

PVC PIPE

AutoCAD SHX Text

WATERSTOP (TYP)

AutoCAD SHX Text

TERMINATE PIPE FLUSH WITH INSIDE MANHOLE SURFACE

AutoCAD SHX Text 6" MIN. THICKNESS FOR MANHOLES UP TO 48" IN DIAMETER, 8" MIN. THICKNESS FOR MANHOLES OVER 48" DIAMETER.

AutoCAD SHX Text NOTE: OFFSET CONE AS SHOWN FOR DROP MANHOLES ONLY. ALL OTHERS SHALL BE CENTERED ON THE SEWER LINE ON THE UPSTREAM SIDE OF THE MANHOLE.

AutoCAD SHX Text

FLOW

AutoCAD SHX Text

FLOW

AutoCAD SHX Text

DETAIL NO.

AutoCAD SHX Text

FILE NAME:

AutoCAD SHX Text

DETAIL NAME:

AutoCAD SHX Text

IHS-STD-BLOCKS-2021

AutoCAD SHX Text

INDIAN HEALTH SERVICE

AutoCAD SHX Text

PUBLIC HEALTH SERVICE

AutoCAD SHX Text

DEPT. OF HEALTH & HUMAN SERVICES

File details come from the government source that posted it. Updated .