B01 Attachment J01f 072100 - Thermal Insulation.pdf
PDF 126 KB Posted
- Attached to
- Duplex Construction at Pine Ridge, Kyle, and Wanblee Federal contract opportunity
- Solicitation number
- 75H70125R00064
About this file
This specification document (Section 072100) details thermal insulation requirements for a duplex building project, covering multiple types of insulation materials and their installation methods. The document specifies six primary insulation types: polyisocyanurate foam-plastic board, extruded polystyrene foam-plastic board, glass-fiber blanket, glass-fiber board, mineral-wool blanket, and mineral-wool board insulation. Key manufacturers include Dow Chemical Company, DuPont, Owens Corning, CertainTeed Corporation, and Johns Manville. Installation guidelines emphasize critical requirements such as maintaining manufacturer's instructions, ensuring undamaged and dry materials, fitting insulation tightly around obstructions, and maintaining specific clearances (e.g., 3-inch clearance around recessed lighting). The specification provides detailed instructions for installation in various contexts, including slab, foundation wall, framed construction, and curtain-wall applications, with specific attention to vapor barriers, mechanical support, and achieving proper insulation density and coverage.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| B01 Attachment J01e 085313 SF - Vinyl Windows.pdf | ||
| B01 Attachment J01d IHS_SD Employee Housing-Crawl House_ARCH_R23_B04 RFI.pdf | ||
| B05 Amend A00003.pdf | ||
| B05 Amend A00002.pdf | ||
| B05 Amend A00001.pdf | ||
| B01 Attachment J01a Duplex Employee Housing Package.pdf | ||
| B01 RFP 75H70125R00064.pdf | ||
| B01 Attachment J07 BID SCHEDULE.xlsx | XLSX spreadsheet | |
| B01 Attachment J01b Specs Vol 1.pdf | ||
| B01 Attachment J05 Past Performance Questionnaire.docx | DOCX document | |
| B01 Attachment J03 Self Performed Calculation Sheet.docx | DOCX document | |
| B01 Attachment J01c Specs Vol 2.pdf | ||
| B01 Attachment J01 Duplex Employee Housing_Site Civil Package.pdf | ||
| B01 Attachment J06 IHS IEE Representation Form.pdf | ||
| B01 Attachment J04 Company Specialized Experience Form Construction.pdf | ||
| B01 Attachment J02 Wage Determination SD20250003.pdf |
Show all 16
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DUPLEX BUILDING AND SITE LOCATIONS THERMAL INSULATION
100% CONSTRUCTION DOCUMENTS 072100 - 1
SECTION 072100
THERMAL INSULATION
PART 1 - GENERAL
1.1 SUMMARY
A. Section Includes:
1. Polyisocyanurate foam-plastic board insulation.
2. Extruded polystyrene foam-plastic board insulation.
3. Glass-fiber blanket insulation.
4. Glass-fiber board insulation.
5. Mineral-wool blanket insulation.
6. Mineral-wool board insulation.
1.2 REFERENCES
1. ASTM E84: Standard Test Method for Surface Burning Characteristics of Building Materials.
2. ICC-ES: International Code Council Evaluation Service.
3. NFPA 286: Standard Methods of Fire Tests for Evaluating Contribution of Wall and
Ceiling Interior Finish to Room Fire Growth.
4. NFPA 285: Standard Fire Test Method for Evaluation of Fire Propagation Characteristics of Exterior Wall Assemblies Containing Combustible Components.
1.3 ACTION SUBMITTALS
A. Product Data: For the following:
1. Polyisocyanurate foam-plastic board insulation
2. Extruded polystyrene foam-plastic board insulation.
3. Glass-fiber blanket insulation.
4. Glass-fiber board insulation.
5. Mineral-wool blanket insulation.
6. Mineral-wool board insulation.
B. Installer's Certification: Listing type, manufacturer, and R-value of insulation installed in each element of the building thermal envelope.
1. Sign, date, and post the certification in a conspicuous location on Project site.
C. Product test reports.
D. Research reports.
E. ICC-ES Evaluation Reports.
100% CONSTRUCTION DOCUMENTS 072100 - 2
1.4 INFORMATION SUBMITTALS
A. Product Test Reports: For each product, for tests performed by a qualified testing agency.
B. Research Reports: For foam-plastic insulation, from ICC-ES.
C. Installer's Certification: Listing type, manufacturer, and R-value of insulation installed in each element of the building thermal envelope.
1. For blown-in or sprayed fiberglass and cellulosic-fiber loose-fill insulation, indicate initial installed thickness, settled thickness, settled R-value, installed density, coverage area, and number of bags installed.
2. Sign, date, and post the certification in a conspicuous location on Project site.
1.5 DELIVERY, STORAGE, AND HANDLING
A. Protect insulation materials from physical damage and from deterioration due to moisture, soiling, and other sources. Store inside and in a dry location. Comply with manufacturer's written instructions for handling, storing, and protecting during installation.
B. Protect foam-plastic board insulation as follows:
1. Do not expose to sunlight except to necessary extent for period of installation and concealment.
2. Protect against ignition at all times. Do not deliver foam-plastic board materials to Project site until just before installation time.
3. Quickly complete installation and concealment of foam-plastic board insulation in each area of construction.
PART 2 - PRODUCTS
2.1 POLYISOCYANURATE FOAM-PLASTIC BOARD INSULATION
A. Polyisocyanurate Board Insulation, Foil Faced: ASTM C1289, foil faced, Type I, Class 1 or 2.
1. Fire Propagation Characteristics: Passes NFPA 285 testing as part of an approved assembly.
2. Labeling: Provide identification of mark indicating R-value of each piece of insulation 12 inches and wider in width.
2.2 EXTRUDED POLYSTYRENE FOAM-PLASTIC BOARD INSULATION
A. Extruded Polystyrene Board Insulation, Type X: ASTM C578, Type X, 15-psi minimum compressive strength; unfaced.
1. Manufacturers: Subject to compliance with requirements, provide products by one of the following:
a. Dow Chemical Company (The).
b. DuPont de Nemours, Inc.
c. Owens Corning.
http://www.specagent.com/Lookup?ulid=11256 http://www.specagent.com/Lookup?uid=123457154998 http://www.specagent.com/Lookup?uid=123457184105 http://www.specagent.com/Lookup?uid=123457154999
100% CONSTRUCTION DOCUMENTS 072100 - 3
2. Flame-Spread Index: Not more than 25 when tested in accordance with ASTM E84.
3. Smoke-Developed Index: Not more than 450 when tested in accordance with ASTM E84.
4. Fire Propagation Characteristics: Passes NFPA 285 testing as part of an approved assembly.
5. Provide Extruded Polystyrene Foam-Plastic Board Insulation suitable for direct burial perimeter foundation insulation.
6. Labeling: Provide identification of mark indicating R-value of each piece of insulation 12 inches (305 mm) and wider in width.
2.3 GLASS-FIBER BLANKET INSULATION
A. Glass-Fiber Blanket Insulation, Unfaced: ASTM C665, Type I;; passing ASTM E136 for combustion characteristics.
1. Manufacturers: Subject to compliance with requirements, provide products by one of the following:
a. CertainTeed Corporation; Saint-Gobain North America.
b. Johns Manville; a Berkshire Hathaway company.
c. Owens Corning.
d. Other approved equal.
2. Flame-Spread Index: Not more than 25 when tested in accordance with ASTM E84.
3. Smoke-Developed Index: Not more than 50 when tested in accordance with ASTM E84.
4. Labeling: Provide identification of mark indicating R-value of each piece of insulation 12 inches and wider in width.
B. Glass-Fiber Blanket Insulation, Polypropylene-Scrim-Kraft Faced: ASTM C665, Type II (nonreflective faced), Class A (faced surface with a flame-spread index of 25 or less);
Category 1 (membrane is a vapor barrier).
1. Labeling: Provide identification of mark indicating R-value of each piece of insulation 12 inches and wider in width.
C. Glass-Fiber Blanket Insulation, Reinforced-Foil Faced: ASTM C665, Type III (reflective faced), Class A (faced surface with a flame-spread index of 25 or less); Category 1 (membrane is a vapor barrier), faced with foil scrim, foil-scrim kraft, or foil-scrim polyethylene.
1. Labeling: Provide identification of mark indicating R-value of each piece of insulation 12 inches and wider in width.
2.4 LOOSE-FILL INSULATION ATTIC INSULATION
A. Cellulosic-Fiber Loose-Fill Insulation Attic: ASTM C739, chemically treated for flame-resistance, processing, and handling characteristics.
B. Glass-Fiber Loose-Fill Insulation: ASTM C764, Type I for pneumatic application.
2.5 ACCESSORIES
A. Insulation for Miscellaneous Voids:
http://www.specagent.com/Lookup?ulid=11272 http://www.specagent.com/Lookup?uid=123457155167 http://www.specagent.com/Lookup?uid=123457155169 http://www.specagent.com/Lookup?uid=123457155170
100% CONSTRUCTION DOCUMENTS 072100 - 4
1. Glass-Fiber Insulation: ASTM C764, Type II, loose fill; with maximum flame-spread and smoke-developed indexes of 5, per ASTM E84.
2. Spray Polyurethane Foam Insulation: ASTM C1029, Type II, closed cell, with maximum flame-spread and smoke-developed indexes of 75 and 450, respectively, per ASTM E84.
B. Insulation Anchors, Spindles, and Standoffs: As recommended by manufacturer.
C. Adhesive for Bonding Insulation: Product compatible with insulation and air and water barrier materials, and with demonstrated capability to bond insulation securely to substrates without damaging insulation and substrates.
PART 3 - EXECUTION
3.1 INSTALLATION, GENERAL
A. Comply with insulation manufacturer's written instructions applicable to products and applications.
B. Install insulation that is undamaged, dry, and unsoiled and that has not been left exposed to ice, rain, or snow at any time.
C. Install insulation with manufacturer's R-value label exposed after insulation is installed.
D. Extend insulation to envelop entire area to be insulated. Fit tightly around obstructions and fill voids with insulation. Remove projections that interfere with placement.
E. Provide sizes to fit applications and selected from manufacturer's standard thicknesses, widths, and lengths. Apply single layer of insulation units unless multiple layers are otherwise shown or required to make up total thickness or to achieve R-value.
3.2 INSTALLATION OF SLAB INSULATION
A. On vertical slab edge and foundation surfaces, set insulation units using manufacturer's recommended adhesive according to manufacturer's written instructions.
1. If not otherwise indicated, extend insulation a minimum of 24 inches below exterior grade line.
B. On horizontal surfaces, loosely lay insulation units according to manufacturer's written instructions. Stagger end joints and tightly abut insulation units.
1. If not otherwise indicated, extend insulation a minimum of 24 inches in from exterior walls.
3.3 INSTALLATION OF FOUNDATION WALL INSULATION
A. Butt panels together for tight fit.
B. Anchor Installation: Install board insulation on concrete substrates by adhesively attached, spindle-type insulation anchors.
100% CONSTRUCTION DOCUMENTS 072100 - 5
C. Adhesive Installation: Install with adhesive or press into tacky waterproofing or dampproofing according to manufacturer's written instructions.
3.4 INSTALLATION OF INSULATION IN FRAMED CONSTRUCTION
A. Blanket Insulation: Install in cavities formed by framing members according to the following requirements:
1. Use insulation widths and lengths that fill the cavities formed by framing members. If more than one length is required to fill the cavities, provide lengths that will produce a snug fit between ends.
2. Place insulation in cavities formed by framing members to produce a friction fit between edges of insulation and adjoining framing members.
3. Maintain 3-inch clearance of insulation around recessed lighting fixtures not rated for or protected from contact with insulation.
4. Attics: Install eave ventilation troughs between roof framing members in insulated attic spaces at vented eaves.
5. For metal-framed wall cavities where cavity heights exceed 96 inches, support unfaced blankets mechanically and support faced blankets by taping flanges of insulation to flanges of metal studs.
6. For wood-framed construction, install blankets according to ASTM C1320 and as follows:
a. With faced blankets having stapling flanges, lap blanket flange over flange of adjacent blanket to maintain continuity of vapor retarder once finish material is installed over it.
7. Vapor-Retarder-Faced Blankets: Tape joints and ruptures in vapor-retarder facings, and seal each continuous area of insulation to ensure airtight installation.
a. Exterior Walls: Set units with facing placed toward interior of construction.
B. Miscellaneous Voids: Install insulation in miscellaneous voids and cavity spaces where required to prevent gaps in insulation using the following materials:
1. Glass-Fiber Insulation: Compact to approximately 40 percent of normal maximum volume equaling a density of approximately 2.5 lb/cu. ft..
2. Spray Polyurethane Insulation: Apply according to manufacturer's written instructions.
3.5 INSTALLATION OF CURTAIN-WALL INSULATION
A. Install board insulation in curtain-wall construction according to curtain-wall manufacturer's written instructions.
1. Hold insulation in place by securing metal clips and straps or integral pockets within window frames, spaced at intervals recommended in writing by insulation manufacturer to hold insulation securely in place without touching spandrel glass. Maintain cavity width of dimension indicated on Drawings between insulation and glass.
2. Install insulation to fit snugly without bowing.
END OF SECTION 072100