B01 Attachment J01d IHS_SD Employee Housing-Crawl House_ARCH_R23_B04 RFI.pdf
PDF 612 KB Posted
- Solicitation number
- 75H70125R00064
About this file
These documents are architectural construction drawings for a duplex residential project for the Indian Health Service (IHS) located in Fort Yates, North Dakota. The project is a two-unit residential building with a crawl space, designed to comply with the 2020 International Residential Code and 2021 International Energy Conservation Code. Key design features include a one-story structure with interior garage, sprinkler system, fire alarm, and separate units with individual living spaces comprising bedrooms, bathrooms, kitchens, laundry areas, and mechanical rooms. The drawings provide detailed specifications for building thermal envelope, fire-resistant construction, insulation requirements, egress provisions, and interior space configurations, with specific attention to energy efficiency standards for Climate Zone 6A and adherence to national building and safety codes.
View the file
Other files
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
RELEVANT CODES AND STANDARDS [LATEST SHALL APPLY]
• NATIONAL FIRE CODES (NFC)
• NFPA 101 – LIFE SAFETY CODE
• INTERNATIONAL RESIDENTIAL CODE (IRC)
• INTERNATIONAL BUILDING CODE (IBC)
• ARCHITECTURAL BARRIERS ACT (ABA) STANDARDS
• INTERNATIONAL ENERGY CONSERVATION CODE (IECC)
• IHS TECHNICAL HANDBOOK
• ASHRAE STANDARD 111 “PRACTICES FOR MEASUREMENT,
TESTING, ADJUSTING, AND BALANCING OF BUILDING HEATING,
VENTILATION, AIR-CONDITIONING AND REFRIGERATION
SYSTEMS.
• ALL APPLICABLE IEEE STANDARDS
• ASHRAE GUIDELINE 0, THE COMMISSIONING PROCESS
• INTERNATIONAL PLUMBING CODE (IPC)
BUILDING DATA
STORIES: 1 W/ CRAWL SPACE
BUILDING AREA:
UNIT A UNIT B TOTAL
LEVEL ONE 1176 1176 2352
TOTAL 2359 2359
OCCUPANCY: RESIDENTIAL - ONE AND TWO-FAMILY DWELLINGS
PER NFPA 101 - 6.1.8.1.1
IECC COMPLIANCE PATH: PRESCRIPTIVE
SPRINKLERED: YES
FIRE ALARM: YES
PARKING: INTERIOR GARAGE W/ DRIVEWAY
AUTHORITY HAVING JURISDICTION (AHJ): DIRECTOR, DIVISION OF
ENGINEERING SERVICES (DES), INDIAN HEALTH SERVICE.
2020 INTERNATIONAL RESIDENTIAL CODE (IRC)
(R101.2) SCOPE: APPLIES TO DETACHED ONE AND TWO-FAMILY DWELLINGS WITH
A SEPARATE MEANS OF EGRESS NO MORE THAN 3 STORIES ABOVE GRADE PLANE.
CHAPTER 3: BUILDING PLANNING
(R302) FIRE-RESISTANT CONSTRUCTION
TABLE R302.1(2) EXTERIOR WALLS (SPRINKLERED BLDGS LPER P2904)
WALL ELEMENT MIN FIRE-RATING MIN FIRE SEPARATION DIST
WALLS FIRE-RATED 1-HR PER IBC 703.3 0 FT
NOT FIRE-RATED 0 HOURS 3 FT
PROJECTIONS
FIRE-RATED 1-HR, HT, OR FRT WOOD 2 FT
NOT FIRE-RATED 0 HOUR 3 FT
OPENINGS
UNLIMITED 0 HOUR 3 FT
PENETRATIONS
ALL COMPLY WITH R302.4 < 3 FT
(R302.3) TWO-FAMILY DWELLINGS
A. DWELLING UNITS TO BE SEPARATED BY WALL AND FLOOR ASSEMBLIES
WITH FIRE RATING >/= 1/2-HR PER ASTM E119, UL 263 OR 703.3 OF IBC.
EXTEND TO EXT WALLS AND FROM FOUNDATION TO UNDERSIDE OF
ROOF SHEATHING.
B. WALL ASSEMBLIES NEED NOT EXTEND THROUGH ATTIC SPACES WHERE:
1. CEILING PROTECTED BY 5/8” TYPE ‘X’ GYPSUM BOARD
2. ATTIC DRAFT STOP PER R302.12.1 PROVIDED ABOVE AND ALONG
SEPARATION WALL AND
3. STRUCTURAL FRAMING SUPPORTING THE CEILING TO BE
PROTECTED BY ½” GYPSUM BOARD OR EQUAL.
a. SUPPORTING CONSTRUCTION OF RATED FLOOR ASSEMBLIES
TO HAVE EQUAL OR GREATER RATING.
(R302.4) DWELLING UNIT FIRE-RATED PENETRATIONS
(R302.4.1) THROUGH PENETRATIONS
(R302.4.2) MEMBRANE PENETRATIONS: COMPLY WITH R302.4.1.
(R302.5) DWELLING TO GARAGE:
(R302.5.1) OPENINGS
(R302.5.2) DUCT PENETRATIONS
TABLE R302.6 DWELLING TO GARAGE FIRE SEPARATION
SEPARATION MATERIAL
RESIDENCE AND ATTICS 1/2 INCH MIN GYPSUM BD
HABITABLE ROOMS ABOVE 5/8 INCH MIN TYPE ‘X’ GYPSUM BD
STRUCTURE FOR FLOOR/CEILING 1/2 INCH MIN GYPSUM BD
GARAGE LOCATED LESS THAN 1/2 INCH MIN GYPSUM BD INTERIOR SIDE
3 FT FROM DWELLING UNIT OF EXTERIOR WALLS.
(R302.7) UNDER-STAIR PROTECTION: PROTECT ENCLOSED SPACE WITH 1/2”
GYPSUM BOARD.
(R302.9) FLAME SPREAD AND SMOKE DEVELOPED INDEX FOR FINISHES.
• WALL AND CEILING FINISHES FLAME SPREAD INDEX </= 200.
• WALL AND CEILING FINISHES SMOKE DEVELOPED INDEX </= 450.
(R302.10.1) INSULATION SHALL HAVE FLAME SPREAD INDEX </= 25 AND SMOKE
DEVELOPED INDEX </= 450. INCLUDES FACINGS, VAPOR RETARDERS, ETC.
(R302.11) FIREBLOCKING: LOCATIONS:
1. STUD WALLS – VERTICALLY AT CEILING AND FLOOR LEVELS.
2. STUD WALLS – HORIZONTALLY AT INTERVALS </= 10 FEET.
3. CONCEALED VERTICAL AND HORIZONTAL SPACES AT SOFFITS, DROP
CEILINGS, ETC.
4. VENT, PIPE, DUCT, CABLES, WIRES AT CEILING AND FLOOR LEVEL WITH
APPROVED FIRE-STOPPING MATERIALS.
5. CHIMNEYS AND FIREPLACES.
(R302.12) DRAFTSTOPPING: INSTALL IN CONCEALED SPACES OF FLOOR-CEILING
ASSEMBLIES TO DIVIDE INTO EQUAL SPACES </= 1000 SF.
(R302.13) FIRE PROTECTION OF FLOORS: IF NOT REQUIRED TO BE FIRE-RATED,
PROTECT UNDERSIDE OF FLOOR FRAMING WITH ½” GYPSUM BOARD MEMBRANE,
5/8” WOOD STRUCTURAL PANEL MEMBRANE, OR EQUAL.
EXCEPTIONS:
1. FLOOR ASSEMBLY OVER SPACE PROTECTED BY SPRINKLERS
2. FLOOR ASSEMBLY OVER SPACE NOT INTENDED FOR STORAGE OR
FUEL-FIRED OR ELECTRIC-POWERED HEATING APPLIANCES.
3. FLOOR ASSEMBLIES PERMITTED TO BE UNPROTECTED IF
UNPROTECTED PORTION </= 80 SQUARE FEET PER STORY.
4. FIREBLOCKING PER R302.11.1 INSTALLED ALONG PERIMETER OF
UNPROTECTED PORTION.
5. WOOD FLOOR ASSEMBLIES USING 2X10 DIMENSION LUMBER OR
EQUAL OR OTHER ASSEMBLY OF EQUIVALENT FIRE PERFORMANCE.
(R302.14) COMBUSTIBLE INSULATION CLEARANCE: KEEP MIN 3 INCHES FROM
RECESSED LIGHTS, FAN MOTORS, ETC. (UNLESS LISTED OTHERWISE).
SECTION R303: LIGHT, VENTILATION, AND HEATING
(R303.5.1) INTAKE OPENINGS: LOCATE NOT LESS THAN 10 FEET FROM
HAZARDOUS OR NOXIOUS CONTAMINANTS.
(R303.5.2) EXHAUST OPENINGS: SHALL NOT BE DIRECTED ONTO WALKWAYS.
SECTION R304: MINIMUM ROOM AREAS
(R304.1) MINIMUM AREA: HABITABLE ROOMS MIN 70 SF.
(R304.2) MINIMUM DIMENSIONS: NOT LESS THAN 7 FEET IN ANY HORIZONTAL
DIRECTION.
(R304.3) HEIGHT EFFECT ON ROOM AREA: FLOOR AREA BELOW SLOPED CEILINGS
LESS THAN 5 FT AND FURRED CEILINGS LESS THAN 7 FT DOES NOT CONTRIBUTE
TO HABITABLE AREA OF ROOM.
SECTION R305: CEILING HEIGHT
(R305.1) MINIMUM HEIGHT: HABITABLE SPACE, HALLWAYS NOT LESS THAN 7 FEET.
BATHROOMS, TOILET ROOMS, LAUNDRY ROOMS NOT LESS THAN 6’-8”.
SECTION R306: SANITATION
(R306.1) TOILET FACILITIES: WATER CLOSET, LAVATORY, AND BATHTUB OR
SHOWER REQUIRED IN EVERY DWELLING UNIT.
SECTION R307: TOILET, BATH, AND SHOWER SPACES
(R307.1) SPACE REQUIRED: FIXTURES SPACED PER P2705.1.
(R307.1) SPACE REQUIRED: FIXTURES SPACED PER P2705.1.
2021 INTERNATIONAL ENERGY CONSERVATION CODE (IECC)
IECC RESIDENTIAL PROVISIONS
CHAPTER 1 [RE]:
(R103.2) INFORMATION REQUIRED ON CONSTRUCTION DOCUMENTS
1. ENERGY COMPLIANCE PATH: PRESCRIPTIVE
(R103.2.1) THERMAL ENVELOPE: REPRESENT ON DOCUMENTS
(R105.2) REQUIRED INSPECTIONS
1. FOOTING AND FOUNDATIONS
2. FRAMING AND ROUGH-IN
3. PLUMBING ROUGH-IN
4. MECHANICAL ROUGH-IN
5. FINAL INSPECTION
SECTION R402: BUILDING THERMAL ENVELOPE
TABLE R402.1.2 MAX U-FACTORS BY COMPONENT (CLIMATE ZONE 6A)
FENESTRATION U-FACTOR 0.30
SKYLIGHT U-FACTOR 0.55
GLAZED FENETRATION SHGC NR
CEILING U-FACTOR 0.024
WOOD FRAME WALL U-FACTOR 0.045
MASS WALL U-FACTOR 0.060
FLOOR U-FACTOR 0.033
BASEMENT WALL U-FACTOR 0.050
CRAWL SPACE WALL U-FACTOR 0.055
TABLE R402.1.3 MIN R-VALUES BY COMPONENT (CLIMATE ZONE 6A)
FENESTRATION U-FACTOR 0.30
SKYLIGHT U-FACTOR 0.55
GLAZED FENETRATION SHGC NR
CEILING R-VALUE 0.060
WOOD FRAME WALL R-VALUE 20+5ci or 13+10ci or 0+20
MASS WALL R-VALUE 15/20
FLOOR R-VALUE 30
BASEMENT WALL R-VALUE 15ci or 19 or 13+5ci SLAB R-VALUE & DEPTH 10ci, 4 FT CRAWL SPACE WALL R-VALUE 15ci or 19 or 13+5ci
(R402.2.1) CEILINGS WITH ATTICS: EXTEND UNCOMPRESSED INSUL OVER WALL TOP
PLATE TO ALLOW LOWER R-VALUE INSUL TO BE USED.
(R402.2.2) CEILINGS WITHOUT ATTICS: WHERED REQUIRED INSULTATION > R-30,
BUT ROOF/CEILING ASSEMBLY DOES NOT ALLOW SUFFICIENT SPACE, MIN UNSUL
VALUE = R-30 FOR MAX 500 SF. INSUL SHALL EXTEND OVER WALL TOP PLATE.
(R402.2.4) ACCESS HATCHES AND DOORS FROM CONDITIONED TO UNCONDITIONED
SPACE – INSULATE TO LEVEL OF ADJACENT WALL.
(R402.2.8) BASEMENT WALLS: INSTALL INSUL FROM TOP OF WALL DOWN TO 10 FT
BELOW GRADE OR TO BASEMENT FLOOR.
(R402.2.9) SLAB-ON-GRADE FLOORS LOCATED LESS THAN 12 INCHES BELOW GRADE:
EXTEND INSULATION FROM TOP OF SLAB (INSIDE OR OUTSIDE OF FOUNDATION
WALL) VERTICALLY, HORIZONTALLY UNDER THE FLOOR SLAB, OR HORIZONTALLY
OUT FROM THE BUILDING (PROTECTED BY PAVEMENT OR 10+ INCHES OF SOIL).
(R402.2.10) INSULATED CRAWL SPACE WALLS: IF CRAWL SPACE NOT VENTED TO
OUTSIDE, INSUL TO EXTEND FROM UNDERSIDE OF FLOOR DOWNWARD TO FINISHED
GRADE AND THEN VERTICALLY OR HORIZONTALLY AN ADDITIONAL 24 INCHES.
EXPOSED EARTH IN UNVENTED CRAWL SPACE TO BE COVERED WITH CONTINUOUS
CLASS 1 VAPOR RETARDER. EXTEND UP FOUNDATION WALLS MIN 6 INCHES.
(R402.4.1) BUILDING THERMAL ENVELOPE: INSTALL PER MFR’S INSTRUCTIONS AND
PER TABLE R402.4.1.1.
(R402.4.3) FENESTRATION AIR LEAKAGE: </= 0.32 CFM PER SF FOR WINDOWS,
SKYLIGHTS, AND SLIDING DOORS, AND </= 0.5 CFM PER SF FOR SWINGING DOORS
PER NFRC 400. EXCEPTION: SITE-BUILT WINDOWS, SKYLIGHTS, AND DOORS.
(R402.5) MAX FENESTRATION U-FACTOR = 0.40 IN CLIMATE ZONE 6. AVERAGE MAX
SHGC = 0.50.
SECTION R308: GLAZING
(R308.1) IDENTIFICATION
(R308.3) HUMAN IMPACT LOADS
(R308.4) HAZARDOUS LOCATIONS:
1. DOORS: GLAZING IN FIXED OR OPERABLE PANELS IN SWINGING,
SLIDING, OR BI-FOLD DOORS.
2. GLAZING ADJACENT TO DOORS: WHERE BOTTOM EDGE OF GLASS < 60
INCHES ABOVE FLOOR OR WALKING SURFACE AND WITHIN 24 INCHES
EITHER SIDE OF THE DOOR IN THE CLOSED POSITION.
3. GLAZING IN WINDOWS: HAS TO MEET ALL THE FOLLOWING CONDITIONS:
• EXPOSED AREA OF INDIVIDUAL PANE LARGER THAN 9 SF.
• BOTTOM EDGE OF GLAZING < 18 INCHES ABOVE THE FLOOR.
• TOP EDGE OF GLAZING > 36 INCHES ABOVE FLOOR.
• WALKING SURFACE WITHIN 36 INCHES OF GLAZING.
(R308.4.5) GLAZING ADJACENT TO HOT TUBS, SPAS, SAUNAS, STEAM ROOMS,
BATHTUBS, SHOWERS, SWIMMING POOLS WHERE BOTTOM EDGE OF GLAZING
LESS THAN 60 INCHES ABOVE ANY STANDING OR WALKING SURFACES.
(R308.4.6) GLAZING ADJACENT TO STAIRS AND RAMPS
(R308.4.7) GLAZING ADJACENT TO BOTTOM LANDING OF STAIR.
SECTION R310: EMERGENCY ESCAPE AND RESCUE OPENINGS
(R301.1) LOCATIONS REQUIRED: BASEMENTS, HABITABLE ATTICS, EVERY
SLEEPING ROOM. TO OPEN DIRECTLY INTO A PUBLIC WAY, YARD OR COURT.
(R310.2.1) MINIMUM OPENING: NET CLEAR AREA >/= 5.7 SF. NET CLEAR MIN
HEIGHT 24 INCHES AND NET MIN CLEAR WIDTH 20 INCHES. MIN NET CLEAR
OPENING FOR AT-GRADE OR BELOW-GRADE OPENINGS >/= 5 SF.
(R310.2.2) WINDOWSILL HEIGHT: </= 44 INCHES ABOVE FLOOR OR IF BELOW
GRADE, PROVIDE A WINDOW WELL.
SECTION R311: MEANS OF EGRESS
(R311.2) EGRESS DOOR: NOT LESS THAN ONE, SIDE-HINGE, MIN WIDTH 32 INCHES,
CLEAR HEIGHT 78 INCHES MIN.
(R311.3) LANDING ON EACH SIDE OF EACH EXTERIOR DOOR REQD. MIN WIDTH >/=
WIDTH OF DOOR, MIN 36 INCHES LONG IN DIRECITON OF TRAVEL.
(R311.3.1) FLOOR ELEVATIONS AT REQUIRED EGRESS DOORS:
(R311.7) STAIRWAYS
(R311.7.1) WIDTH: NOT LESS THAN 36” CLEAR ABOVE HANDRAIL HEIGHT, MIN 31 1/2”
BELOW HANDRAIL. (31 1/2” WHERE HANDRAIL ON ONE SIDE)
(R311.7.2) HEADROOM: MIN 6’-8”.
(R311.7.3) VERTICAL RISE: MAX RISE FOR A FLIGHT OF STAIRS 151 INCHES
BETWEEN FLOORS OR LANDINGS.
(R311.7.8.1) HANDRAIL HEIGHT: >/= 34 INCHES NOR MORE THAN 38 INCHES
(R311.7.8.4) CONTINUITY: CONTINUOUS FOR FULL LENGTH OF THE FLIGHT.
(R311.8) RAMPS: MAX SLOPE FOR EGRESS DOORS 1:12. OTHER RAMPS MAX 1:8.
WHERE TECHNICALLY INFEASIBLE, RAMPS CAN HAVE MAX SLOPE 1:8.
(R311.8.2) LANDINGS REQUIRED AT TOP AND BOTTOM, AT DOORS, AT DIRECTION
CHANGES, MIN WIDTH 36”.
(R311.8.3) HANDRAILS REQUIRED ON MIN ONE SIDE WHERE SLOPE > 1:12.
(R311.8.3.1) HANDRAIL HEIGHT: >/= 34 INCHES OR MORE THAN 38 INCHES.
(R311.8.3.3) HANDRAILS: TO BE CONTINUOUS FOR FULL LENGTH OF RAMP.
SECITON R312: GUARDS AND WINDOW FALL PROTECTION:
(R312.1) GUARDS: PROVIDE AT OPEN SIDE OF WALKING SURFACES > 30 INCHES
ABOVE ADJACENT FLOOR OR GRADE. MIN HEIGHT 36 INCHES. INSECT SCREEN
NOT CONSIDERED A GUARD. NO OPENINGS TO ALLOW PASSAGE OF 4 INCH
SPHERE.
(R312.2) WINDOW FALL PROTECTION: WHERE WINDOW SILL LESS THAN 24 INCHES
ABOVE FINISHED FLOOR AND MORE THAN 72 INCHES ABOVE GRADE:
• WINDOW OPENING SHALL NOT ALLOW PASSAGE OF 4 INCH SPHERE, OR
• WINDOW PROVIDED WITH FALL PROTECTION PER ASTM F2090, OR
• WINDOW PROVIDED WITH OPENING CONTROL DEVICES PER SECTION
R310.2.1.
(R312.2.2) WINDOW OPENING CONTROL DEVICES. WILL ALLOW WINDOW TO OPEN
FULLY AS REQUIRED PER SECTION R310.2.1.
SECTION R314: SMOKE ALARMS PER NFPA 72 AND SECTION R314: SHALL BE
PROVIDED IN DWELLING UNITS (OR COMBINATION SMOKE AND CARBON
MONOXIDE ALARM)
(R314.3) LOCATIONS:
• EACH SLEEPING ROOM
• OUTSIDE EACH SLEEPING AREA IN VICINITY OF BEDROOMS
• ON EACH ADDITIONAL STORY INCLUDING BASEMENTS AND HABITABLE
ATTICS
• NOT LESS THAN 3 FEET FROM DOOR OPENING IN BATHROOM HAVING
BATHTUB OR SHOWER
• NOT LESS THAN 20 FEET FROM COOKING APPLIANCE (10 FEET IF
IONIZATION TYPE OR 6 FEET IF PHOTOELECTRIC TYPE)
(R314.4) IF ONE ALARM IS ACTIVATED, ALL ALARMS SHALL BE ACTIVATED.
SECTION R315: CARBON MONOXIDE ALARMS: REQUIRED WHERE DWELLING UNIT
CONTAINS A FUEL-FIRED APPLIANCE OR HAS AN ATTACHED GARAGE WITH AN
OPENING THAT COMMUNICATES WITH THE DWELLING UNIT.
SECTION R316: FOAM PLASTIC TO HAVE FLAME SPREAD INDEX NOT MORE THAN
75 AND SMOKE DEVELOPED INDEX NOT MORE THAN 450.
(R316.4) THERMAL BARRIER: SEPARATE FOAM PLASTIC FROM INTERIOR OF
BUILDING BY A LAYER OF NOT LESS THAN ONE-HALF INCH GYPSUM BOARD, 23/32
INCH WOOD STRUCTURAL PANEL, OR OTHER MATERIAL APPROVED PER NFPA 275.
(R316.5.2) ROOFING: THERMAL BARRIER PER SECTION R316.4 NOT REQUIRED
WHERE FOAM PLASTIC UNDER ROOF COVERING IS SEPARATED FROM INTERIOR
BY T&G WOOD PLANKS OR WOOD STRUCTURAL SHEATHING NOT LESS THAN 15/32
INCHES THICK EXTERIOR GLUE.
(R316.5.5) FOAM-FILLED EXTERIOR DOORS: EXEMPT FROM REQUIREMENTS OF
R316.3 AND R316.4.
(R316.5.6) FOAM-FILLED GARAGE DOORS: EXEMPT FROM REQUIREMENTS OF
R316.3 AND R316.
B.O. STRUCTURE
CEILING LINE
FLOOR LINE
2 X 4 WOOD STUDS @ 16"
O.C. W/ SOUND BATT.
2 X 4 WOOD STUDS @ 16"
O.C. (NO SOUND BATT.)
5/8" TYPE "X"
GYPSUM BOARD
A1
A2
2 X 4 WOOD STUDS @ 16"
O.C. (NO SOUND BATT.)
5/8" TYPE "X"
GYPSUM BOARD
6" WOOD STUDS @ 16"
O.C. (NO SOUND BATT.)
5/8" TYPE "X"
GYPSUM BOARD
2 x 4 WOOD STUDS @ 16"
O.C. W/ SOUND BATT.
B1
B2
A1 B1 C1A2 B2 C2
2 X 6 WOOD STUDS @
16"O.C. W/ SOUND BATT.
C2
C1
TREATED SILL PLATE
WHEN IN CONTACT W/
CONCRETE FLOOR
TREATED SILL PLATE
WHEN IN CONTACT W/
CONCRETE FLOOR
5/8" TYPE "X"
GYPSUM BOARD
D1
2 X 4 WOOD STUDS @
16"O.C. W/ SOUND BATT.
1"
PLYWOOD SHEATHING
WOOD TRUSS, RE:
STRUCTURAL DRAWINGS
R1
STANDING SEAM METAL ROOF
UNDERLAYMENT
CORNER INTERSECTION
METAL CORNER BEAD - FORM TIGHT 90 DG.
CORNER AND SCREW TO STUD
3 COAT JOINT COMPOUND COVER BEAD AND
FEATHER FOR SMOOTH FINISH
TYP. WOOD STUD AND DRYWALL SCREWS
JOINT TAPE, TYP.
5 GWB AS NOTED
ELEVATION
WOOD STUDS; SPACING AS
SPECIFIED
SUB FLOOR
SHEAR WALL BLOCKING;
RE: STRUCT
NOTE:
INSTALL DBL. STUDS AT WALL
MOUNTED PLBG. & ELECT. FIXTURES,
COUNTERS, TOILET PARTITIONS AND
OTHER SIMILAR EQUIP. LOCATIONS.
DOUBLE TOP PLATE
LAP DOUBLE TOP PLATE MIN 4'-0"
TOP CRIPPLES
HEADER; RE: STRUCT.
KING STUD
SILL 21
BOTTOM CRIPPLES5
TRIMMER STUD6
BOTTOM PLATE9
ROUGH OPENING
WINDOW
ROUGH OPENING
DOOR
R O
U G
H O
P E
N
IN
G
D O
O R
R O
U G
H O
P E
N
IN
G
W
IN
D O
W
R
SEH Project
Checked By
Drawn By
Project Status Issue Date
This drawing is an instrument of service and shall remain the property of Short Elliott Hendrickson, Inc.
(SEH). This drawing, concepts and ideas contained herein shall not be used, reproduced, revised, or retained without the express written approval of SEH.
Submission or distribution of this drawing to meet official or regulatory requirements or for purposes in connection with the project is not be construed as publication in derogation of any of the rights of SEH.
Project Owner
S ho rt E lli ot t H en dr ic ks on
, I nc
A ll
R ig ht s
R es er ve d
C O
P Y
R
IG
H T
Indian Health Service (IHS) Department of Health and Human Services Division of Engineering Services 701 Fifth Avenue, MS 24, Suite 1600 Seattle, Washington 98104-7307
8/
/2
2:
:1
P
M
CODE INFORMATION AND
CONSTRUCTION
ASSEMBLIES
S
IT
E A
D A
P T
D U
P L
E X
F
O R
T Y
A T
E S
, N D
D U
P L
E X
P A
C K
A G
E
C R
A W
L S
P A
C E
F
IF
T H
A V
E N
U E
, M S
4, S U
IT
E
S
E A
T T
LE
, W
A S
H
IN
G T
O N
4-
177917
A. JAUCH
J. HEGG
IN
D
IA
N
H E
A
LT
H S
E R
V
IC
E
G R
E A
T P
LA
IN
S A
R E
A
CONSTRUCTION
DOCUMENTS
03.31.2025
A002
CODE ANALYSIS
1 1/2" = 1'-0"A002
1 PARTITION TYPES
1" = 1'-0"A002
2 ROOF ASSEMBLIES
3" = 1'-0"A002
4 GWB PARTITION DETAILS - WOOD STUDS
1" = 1'-0"A002
5 WOOD STUD FRAMING DETAIL
REVISION SCHEDULE
REV. # DESCRIPTION DATE
WH W
D
W D
WH
A202
A201
A201
A202
A411
'-6
26'-0" 3 1/2" 15'-5 1/2" 8" 15'-5 1/2" 3 1/2" 26'-0"
'-1
25'-0 1/2" 3 1/2" 2'-1" 3 1/2" 13'-7"
6' -2
5'
-0
3'-7"
3 1/2" 7'-9 1/2"
'-3
/4
1/ 2"
2' -1
1/ 2"
'-1
/4
5'-3" 5'-11 1/2"
15'-11"
4' -6
A411
BEDROOM 1
101A
BEDROOM 2
104A
BATHROOM
107A
HALLWAY
105A
LIVING/DINING
110A
MECH
113A
ENTRY
108A
GARAGE
115A
'-0
'-4
42'-1" 42'-1"
26'-0" 16'-1" 16'-1" 26'-0"
CLOSET
102A
LINEN
106A
CLOSET
109A
CLOSET
103A
101A
108B
104B
101B
107B
103B
102B
108A
104A
107A
103A
102A
115A
111B
106B106A 109A
110A
LIVING/DINING
110B
KITCHEN
111B
MECH
113B
CLOSET
109B
ENTRY
108B BATHROOM
107B
HALLWAY
105B
BEDROOM 1
101B
CLOSET
102B
BEDROOM 2
104B
CLOSET
103B
LINEN
106B
GARAGE
115B
115B
5'-8" 3'-0" 10'-3" 3'-0" 3" 5'-0" 3" 3'-0" 2'-1" 3'-2" 1'-7" 3'-0" 1'-6" 4"
4' -7
3'
-0
'-1
0" 3'
-0
4' -7
110B
4" 1'-6" 3'-0" 1'-7" 3'-2" 2'-1" 3'-0" 3" 5'-0" 3" 3'-0" 10'-3" 3'-0" 5'-8"
'-0
5'-8" 3'-0" 11'-7 1/2" 5'-0" 8 1/2" 8 1/2" 5'-0" 11'-7 1/2" 3'-0" 5'-8"
84'-2"
2'-11" 9'-2" 4'-0" 4'-0" 9'-2" 2'-11"
4' -7
3'
-0
'-1
0" 3'
-0
4' -7
A301
A301
LAUNDRY
114B
KITCHEN
111A
113A 111A
LAUNDRY
114A
4'-9 1/2" 3'-1"
5' -7
PANTRY
112A
109B
PANTRY
112B
A411 45
113B
114B114A
A311
A311
112B112A
DW DW
W1
W1
W1
W1W1W2W1
W1
W1
W1
W1 W1 W2 W1 W1 W1
1 HOUR FIRE
PARTITION
1 HOUR FIRE
PARTITION
ATTIC ACCESS
HATCH 20"x30"
MIN CLEAR
ATTIC ACCESS
HATCH 20"X30"
MIN CLEAR
B1
1' -5
W1 W1
B2
7' -1
0" 3'
-0
9' -6
7' -1
0" 3'
-0
9' -6
CRAWL SPACE
ACCESS HATCH
18"x24" MIN CLEAR
CRAWL SPACE
ACCESS HATCH
18"x24" MIN .CLEAR
TOP OF CONCRETE STOOP 7" MAX
BELOW TOP OF FINISHED FLOOR
4'-0"
3' -0
4'-0"
3' -0
A2
A2
A1
A1A1 A2
A2
A1
A2
A1A1
A1
A1 A2
A2
A1
A1
A1
A1
A2
B1
D1
ATTIC ACCESS
HATCH 20"X30"
MIN CLEAR
ATTIC ACCESS
HATCH 20"X30"
MIN CLEAR
R
SEH Project
Checked By
Drawn By
Project Status Issue Date
This drawing is an instrument of service and shall remain the property of Short Elliott Hendrickson, Inc.
(SEH). This drawing, concepts and ideas contained herein shall not be used, reproduced, revised, or retained without the express written approval of SEH.
Submission or distribution of this drawing to meet official or regulatory requirements or for purposes in connection with the project is not be construed as publication in derogation of any of the rights of SEH.
Project Owner
S ho rt E lli ot t H en dr ic ks on
, I nc
A ll
R ig ht s
R es er ve d
C O
P Y
R
IG
H T
Indian Health Service (IHS) Department of Health and Human Services Division of Engineering Services 701 Fifth Avenue, MS 24, Suite 1600 Seattle, Washington 98104-7307
8/
/2
2:
:1
P
M
FLOOR PLAN - GROUND
FLOOR
S
IT
E A
D A
P T
D U
P L
E X
F
O R
T Y
A T
E S
, N D
D U
P L
E X
P A
C K
A G
E
C R
A W
L S
P A
C E
F
IF
T H
A V
E N
U E
, M S
4, S U
IT
E
S
E A
T T
LE
, W
A S
H
IN
G T
O N
4-
177917
A. JAUCH
J. HEGG
IN
D
IA
N
H E
A
LT
H S
E R
V
IC
E
G R
E A
T P
LA
IN
S A
R E
A
CONSTRUCTION
DOCUMENTS
03.31.2025
A102
PROJECT
NORTH
1/4" = 1'-0"A102
1 FLOOR PLAN - GROUND FLOOR
GENERAL NOTES
1. FIELD VERIFY ALL DIMENSIONS. NOTIFY OWNER IF DIMENSIONS VARY SIGNIFICANTLY.
2. ALL DIMENSIONS TO FACE OF WOOD STUD UNLESS NOTED OTHERWISE.
3. ALL INTERIOR WALLS TO BE WALL TYPE A-1 UNLESS NOTED OTHERWISE
W D
WH
A411
A411 45
KITCHEN
111B
PANTRY
112B
CLOSET
109B
LAUNDRY
114B
MECH
113B
DW
3' -3
3'
-1
1/ 2"
6' -1
/4
2'
-5
/2
3'-4 1/2"
4' -2
/4
3'
-3
/4
3'-3 1/4" 2'-7 1/2" 2'-1 1/4"
42" CLEAR
5' -7
9'
-1
1/ 4"
4'-7 3/4"
09.02
09.02
09.01
22.04
09.02 22.06
09.02
09.02
09.01
3' -0
3' -7
/2
09.02
11.03
09.01
09.02 11.01
11.02
09.02
08.0108.01 08.01
09.02
09.01
09.02
11.01
11.02
1 1/2"1'-6" 2'-6" 1'-6"1 1/2"
08.01
11.03 09.02 22.06
09.01
3' -0
09.02
1 1/2" 2'-9" 3'-0" 3'-0"
1'-6" 3'-0"
3' -0
09.02
09.01
09.02
A411 8
4'-9 3/4"
CL22.09
22.08
22.01
12.02
22.02
12.03 2' -6
/4
22.03
8' -1
/2
2'
-6
'-7
/2
1' -6
6' -6
1'-3 1/4"
CL
12.01
12.02
22.01
22.03
12.03
22.02
09.01
09.02
6' -6
22.10
22.09
22.03
22.01
12.01
06.09
1' -0
2'
-6
1' -8
2'
-1 0"
8' -0
1/
2" 2'
-4
/2
4"
2'-1"
1'-2 1/2"
1'-8" 4"
WHITE MELAMINE ADJUSTABLE
SHELVES
OAK DOORS
STAINLESS STEEL WIRE PULLS
OAK CABINET
SOLID SURFACE (SS-1)
COUNTERTOP W/ 4" BACK &
SIDE SPLASH
OAK CABINET
STAINLESS STEEL WIRE PULLS
BASE - REFER TO SCHEDULE
WHITE MELAMINE
ADJUSTABLE SHELVES
R
SEH Project
Checked By
Drawn By
Project Status Issue Date
This drawing is an instrument of service and shall remain the property of Short Elliott Hendrickson, Inc.
(SEH). This drawing, concepts and ideas contained herein shall not be used, reproduced, revised, or retained without the express written approval of SEH.
Submission or distribution of this drawing to meet official or regulatory requirements or for purposes in connection with the project is not be construed as publication in derogation of any of the rights of SEH.
Project Owner
S ho rt E lli ot t H en dr ic ks on
, I nc
A ll
R ig ht s
R es er ve d
C O
P Y
R
IG
H T
Indian Health Service (IHS) Department of Health and Human Services Division of Engineering Services 701 Fifth Avenue, MS 24, Suite 1600 Seattle, Washington 98104-7307
8/
/2
2:
:1
P
M
ENLARGED KITCHEN AND
BATHROOM PLANS AND
INTERIOR ELEVATIONS
S
IT
E A
D A
P T
D U
P L
E X
F
O R
T Y
A T
E S
, N D
D U
P L
E X
P A
C K
A G
E
C R
A W
L S
P A
C E
F
IF
T H
A V
E N
U E
, M S
4, S U
IT
E
S
E A
T T
LE
, W
A S
H
IN
G T
O N
4-
177917
A. JAUCH
J. HEGG
IN
D
IA
N
H E
A
LT
H S
E R
V
IC
E
G R
E A
T P
LA
IN
S A
R E
A
CONSTRUCTION
DOCUMENTS
03.31.2025
A411
1/2" = 1'-0"A411
1 ENLARGED PLAN - KITCHEN
1/4" = 1'-0"A411
2 KITCHEN - NOTRH
1/4" = 1'-0"A411
3 KITCHEN - SOUTH
1/4" = 1'-0"A411
4 KITCHEN - EAST
1/4" = 1'-0"A411
5 KITCHEN - WEST
1/4" = 1'-0"A411
6 BUFFET
KEYNOTE LEGEND
06.09 LAMINATE SHELFING W/ SUPPORT BRACKETS
08.01 WOOD DOOR, RE: DOOR SCHEDULE
09.01 PLAM COUNTERTOP W/3 MIL EDGE AND SET ON BACKSPLASH
09.02 OAK FINISH CABINET
11.01 RANGE, SPEC: TBD
11.02 MICROWAVE, SPEC: TBD
11.03 FRIDGE, SPEC: TBD
12.01 CURTAIN ROD, SPEC: TBD
12.02 TOILET PAPER DISPENSER, SPEC: TBD
12.03 VANITY MIRROR, SPEC: TBD
22.01 FLOOR MOUNTED WATER CLOSET, RE:PLUMB.
22.02 LAVATORY, RE: PLUMB.
22.03 ONE PIECE FIBERGLASS SHOWER SURROUND WITH TUB, SPEC: TBD
22.04 KITCHEN SINK, RE: PLUMB.
22.06 DISHWASHER, SPEC: TBD
22.08 CURTAIN ROD, SPEC: TBD
22.09 TOWEL HOOK, SPEC: TBD
22.10 SHOWER HEAD, RE: SPEC.
GENERAL NOTES
1. FIELD VERIFY ALL DIMENSIONS. NOTIFY OWNER IF DIMENSIONS VARY SIGNIFICANTLY.
2. ALL DIMENSIONS TO FACE OF WOOD STUD UNLESS NOTED OTHERWISE.
3. ALL INTERIOR WALLS TO BE WALL TYPE A-1 UNLESS NOTED OTHERWISE
1/2" = 1'-0"A411
7 ENLARGED PLAN - LEVEL 1
1/4" = 1'-0"A411
8 BATHROOM ELEV. - WEST
1/4" = 1'-0"A411
9 BATHROOM ELEV. - SOUTH
3/4" = 1'-0"A411
11 STANDARD HT. CASEWORK, TYP.
| Sheets |
| A002 - CODE INFORMATION AND CONSTRUCTION ASSEMBLIES |
| A102 - FLOOR PLAN - GROUND FLOOR |
| A411 - ENLARGED KITCHEN AND BATHROOM PLANS AND INTERIOR ELEVATIONS |
File details come from the government source that posted it. Updated .