B05 Amendment 7.pdf

PDF 4 MB Posted

Attached to
Gallup Indian Medical Center (GIMC) Emergency Department (ED) Renovation and Expansion
Solicitation number
75H70124R00012
Issued by

About this file

This is a solicitation notice for a construction project to renovate and expand the Gallup Indian Medical Center Emergency Department in Gallup, New Mexico. The project scope includes renovating approximately 9,671 gross square feet of existing and new space in the first floor east wing to alleviate current space deficiencies. Site work and ambulance entrance driveway work are also required. The estimated construction value is between $5-10 million. The period of performance is 550 calendar days from notice to proceed using firm fixed price contracting. The solicitation will use request for proposal procedures according to FAR Parts 15 and 36. Proposals are due by the date and time specified in the SF1442. Evaluation will use the tradeoff process stated in FAR 15.101-1. The responsible agency is the Indian Health Service. Offerors must register in SAM and check for amendments frequently on the listed website.

View the file

Other files

Show all 22

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:

(a) By completing items 8 and 15, and returning or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

E. IMPORTANT: Contractor is not is required to sign this document and return copies to the issuing office.

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT 1. CONTRACT ID CODE

2. AMENDMENT/MODIFICATION NUMBER 3. EFFECTIVE DATE 4. REQUISITION/PURCHASE REQUISITION NUMBER 5. PROJECT NUMBER (If applicable)

7. ADMINISTERED BY (If other than Item 6) CODE

STANDARD FORM 30 (REV. 11/2016)

Prescribed by GSA FAR (48 CFR) 53.243

FACILITY CODE

9A. AMENDMENT OF SOLICITATION NUMBER

9B. DATED (SEE ITEM 11)

10A. MODIFICATION OF CONTRACT/ORDER NUMBER

10B. DATED (SEE ITEM 13)

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers is extended. is not extended.

12. ACCOUNTING AND APPROPRIATION DATA (If required) copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.

IT MODIFIES THE CONTRACT/ORDER NUMBER AS DESCRIBED IN ITEM 14.

CHECK ONE A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER

NUMBER IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation data, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority)

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15C. DATE SIGNED

15A. NAME AND TITLE OF SIGNER (Type or print)

16C. DATE SIGNED

16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

PAGE OF PAGES

6. ISSUED BY CODE

8. NAME AND ADDRESS OF CONTRACTOR (Number, street, county, State and ZIP Code) (X)

CODE

15B. CONTRACTOR/OFFEROR

(Signature of person authorized to sign)

16B. UNITED STATES OF AMERICA

(Signature of Contracting Officer)

Previous edition unusable

A00007

Andrew Hart, Contracting Officer

See SF30 Continuation Page.

Indian Health Service - DES Seattle 701 5th Avenue, Suite 1600 Seattle, WA 98104

See Item 6

75H70124R00012

NA21GA099H8

1 25

01/24/2024

11/29/2023

SF30 Continuation Page 2

The purpose of amendment 7 to solicitation 75H70124R00012 is the following:

1. Incorporate site visit roster dated 1/19/2024.

2. Incorporate sign schedule A602 revision 3 dated 1/24/2024.

3. Incorporate substitution request dated 1/18/2024. This request (brand name) is in addition to the brand name identified in the project documents.

4. Incorporate RFI responses 1-26.

5. The offer due date remains unchanged at 12:00pm Pacific time on 2/1/2024.

6. All other terms and conditions remain unchanged.

UP

DN

R E

F

7 7/8"

7 7/8"

BLACK PLASTIC

END CAP

RAISED

PICTOGRAMS

ON ACRYLIC

INSERT.

1/4" HIGH

BRAILLE ON

ACRYLIC

INSERT, RAISED

1/32" 1

/8

/4

/8

BLACK

PLASTIC

END CAP

ALUMINUM

FRAME

BLACK

PLASTIC

END CAP

PLAN

FRONT ELEVATIONSIDE ELEVATION

PATIENT RESTROOM

GRAPHICS AND

TEXT SHALL BE

A COMPUTER

GENERATED

TRANSPARENCY

INSERT BEHIND

ACRYLIC

FINAL VERBIAGE

TO BE

DETERMINED BY

CONTRACTING

OFFICER

/8

/4

/8

5 7/8"

5 7/8"

/8

/8

"1 /4

/8

/8

/4

/8

/8

BLACK PLASTIC

END CAP

RAISED CHARACTERS ON

ACRYLIC INSERT,

MINIMUM HEIGHT SHALL

BE 5/8" HIGH

1/4" HIGH BRAILLE ON

ACRYLIC INSERT,

RAISED 1/32"

GRAPHICS AND TEXT

SHALL BE A COMPUTER

GENERATED

TRANSPARENCY

INSERT BEHIND

ACRYLIC

/8

/4

/8

BLACK

PLASTIC

END CAP

ALUMINUM

FRAME

BLACK

PLASTIC

END CAP

PLAN

FRONT ELEVATIONSIDE ELEVATION

1E225

SOILED UTILITY

FINAL VERBIAGE

TO BE

DETERMINED BY

CONTRACTING

OFFICER

ROOM

1'-3 3/4"

1'-3 3/4"

PLAN

FRONT ELEVATION

/2 "2

/2

" 2

/2 "2

/2

" 2

/2 "2

/2

" 2

/2

/2

GRAPHICS AND

TEXT SHALL BE A

COMPUTER

GENERATED

TRANSPARENCY

INSERT BEHIND

ACRYLIC

BLACK

PLASTIC END

CAP

/8

'-1

/2

/8

ALUMINU

M FRAME

BLACK

PLASTI

C END

CAP

SIDE ELEVATION

GRAPHICS AND

TEXT SHALL BE A

COMPUTER

GENERATED

TRANSPARENCY

INSERT BEHIND

ACRYLIC

FINAL VERBIAGE

AND DIRECTION

TO BE

DETERMINED BY

CONTRACTING

OFFICER

DIRECTORY

FIRST FLOOR

ULTRA SOUND

BLOOD LAB

RADIOLOGY

CORRESPONDENCE

MAMMOGRAM

DEXA SCAN

CT SCAN

1'-3 3/4"

FRONT ELEVATION

ED PATIENT REGISTRATION

ULTRA SOUND

BLOOD LAB

URGENT CARE CLINIC

/2 "2

/2

" 2

/2 "2

/2

" 2

/2 "2

/2

" 2

/2

/2

GRAPHICS AND

TEXT SHALL BE A

COMPUTER

GENERATED

TRANSPARENCY

INSERT BEHIND

ACRYLIC

BLACK

PLASTIC END

CAP

/8

'-1

/2

/8

ALUMINU

M FRAME

BLACK

PLASTI

C END

CAP

SIDE ELEVATION

GRAPHICS AND

TEXT SHALL BE A

COMPUTER

GENERATED

TRANSPARENCY

INSERT BEHIND

ACRYLIC

DIRECTORY

FIRST FLOOR

RADIOLOGY

CORRESPONDENCE

MAMMOGRAM

DEXA SCAN

CT SCAN

FINAL VERBIAGE

AND DIRECTION

TO BE

DETERMINED BY

CONTRACTING

OFFICER

1'-3 3/4"

PLAN

EMERGENCY EXIT ONLY 3

OF DOOR

BOTTOM OF LETTER

@ 5'-6" A.F.F.

RED VINYL DIE-CUT

LETTERS, ARIAL

FONT 75%

CHARACTER WIDTH.

FINAL VERBIAGE

TO BE

DETERMINED BY

CONTRACTING

OFFICER

NO SMOKING

NO FIREARMS

/2

/2

OF GLAZING

' A

F F

WHITE VINYL DIE-CUT

LETTERS

FINAL VERBIAGE

TO BE

DETERMINED BY

CONTRACTING

OFFICER

8 1/2"

8 1/2"

BLACK PLASTIC

END CAP

PLAN

FRONT ELEVATION

EXIT MAP

/8

/4

/8

BLACK

PLASTIC

END CAP

ALUMINUM

FRAME

BLACK

PLASTIC

END CAP

SIDE ELEVATION

RAISED

CHARACTERS

ON ACRYLIC

INSERT,

MINIMUM

HEIGHT SHALL

BE 5/8" HIGH.

1/4" HIGH

BRAILLE ON

ACRYLIC

INSERT, RAISED

1/32"

COMPUTER

GENERATED

GRAPHICS ON

PAPER BEHIND

TRANSPARENCY

/8

/8

/4

/8

6"

SOLID

ALUMINUM

SHEET

SURFACE APPLIED FLAT

GRAPHICS COLOR:

BLACK. MINIMUM HEIGHT

SHALL BE 5/8" HIGH.

SURFACE APPLIED

RAISED BRAILLE, 1/32"

MIN.

GRAPHICS AND TEXT

SHALL BE APPLIED

BAKED ENAMEL OR

POWDER COAT

SOLID

ALUMINUM

SHEET

FASTENER

S

PLAN

FRONT ELEVATIONSIDE ELEVATION

1S116

EMS

FINAL VERBIAGE

TO BE

DETERMINED BY

CONTRACTING

OFFICER

BACKGROUND COLOR:

WHITE.

/8

"5 /8

/4

/8

" 1

/4

/8

A B

O V

E G

R A

D E

'-0

STORAGE

1'-6"

'-0

PLAN

FRONT ELEVATION

FINAL VERBIAGE

TO BE

DETERMINED BY

CONTRACTING

OFFICER

BACKGROUND COLOR: WHITE

SURFACE APPLIED FLAT GRAPHICS

COLOR: RED.

SOLID ALUMINUM SHEET

GRAPHICS AND TEXT SHALL BE

APPLIED BAKED ENAMEL OR

POWDER COAT

FASTENER

S

A B

O V

E G

R A

D E

NO

SMOKING

R 3/8"

SURFACE APPLIED FLAT TEXT

COLOR: BLACK.

SURFACE APPLIED FLAT GRAPHIC

COLOR: BLACK.

2'-6"

'-4

PLAN

FRONT ELEVATION

SHORT TERM PARKING

FOR EMERGENCY &

LAW ENFORCEMENT

VEHICLES

FINAL VERBIAGE

TO BE

DETERMINED BY

CONTRACTING

OFFICER

BACKGROUND

COLOR: WHITE

" 1

"2 " 1

"2 " 1

"2

" SURFACE APPLIED

FLAT GRAPHICS

COLOR: BLACK.

R 3/8"

SOLID ALUMINUM

SHEET

GRAPHICS AND

TEXT SHALL BE

APPLIED BAKED

ENAMEL OR

POWDER COAT

FASTENER

S

A B

O V

E G

R A

2'-8"

'-6

PLAN

FRONT ELEVATION

SHUT OFF

YOUR

ENGINE

WHILE

PARKED

FINAL VERBIAGE

TO BE

DETERMINED BY

CONTRACTING

OFFICER

BACKGROUND

COLOR: WHITE

SURFACE APPLIED

FLAT GRAPHICS

COLOR: RED.

R 3/8"

SOLID ALUMINUM

SHEET

GRAPHICS AND

TEXT SHALL BE

APPLIED BAKED

ENAMEL OR

POWDER COAT

FASTENER

S

A B

O V

E G

R A

/2

'-0

A/B

NOTE: WHEN SIGN CANNOT BE IMMEDIATELY ADJACENT TO DOOR FRAME, MOUNT

ON SIDE WALL NEAR LEVER HANDLE. MOUNTING LOCATION SHALL BE SO THAT A

PERSON MAY APPROACH WITHIN 3 INCHES OF SIGNAGE WITHOUT INCOUNTERING

PROTRUDING OBJECTS OR STANDING WITHIN THE SWING OF A DOOR. SIGN

INSTALLER TO SUBMIT SHOP DRAWINGS SHOWING ACTUAL SIGN INSTALLATION

LOCATION.

4" TYP. 4" TYP.

A/B A/BC/F

15 16 17 18 19 20 21 22

AeAe

Be

B.1

F.1

G

H

G.5

FF

E

F

G.4

UC PASSAGE

1E254

RAD

1E255

CLOSET

1E256

'-6

Patient Waiting

1E35

STAIR EAST

1E95

South Corridor

1S148

ED MED CHIEF

1S105

SCN

1S109

BEREAVMENT

1S102

SCN ASST

1S104

PAT REG SUP

1S106

BENE COORD

1S101

REGISTRATION

1S100

CORRIDOR

1S103

CORRIDOR

1S108

AMBULANCE ENT

1E151

ISO(15)

1E153

LOCKERS

1S115

ALCOVE

1S114

STAFF RR

1S116

OBSERV (21)

1S111

OBSERV (20)

1S112

STAFF RR

1S110

C.LINEN

1E161

TLT/SHR

1E160 TRAUMA 01 (17)

1E146

TRAUMA 02 (16)

1E142

MED

1E140

EXAM/TR (14)

1E138

WAITING (45)

1E133

IT

1E129

UTIL SOIL

1E131

REC

1E134

TOILET PAT

1E132

CORRIDOR

1E127

TRIAGE 01

1E137

EXAM/TR (13)

1E143

HSKP

1E124

TOILET PAT

1E139

ELEC

1E116

DIETARY

1E145

UTIL CLEAN

1E147

EQ STOR

1E102

EXAM/TR (01)

1E104

EXAM/TR (02)

1E106

EXAM/TR (03)

1E109

EXAM/TR (04)

1E111

EXAM/TR (05)

1E113

EXAM/TR (06)

1E115

EXAM/TR (07)

1E117

EXAM/TR (08)

1E119

EXAM/TR (09)

1E121 TOILET PAT

1E123

STOR

1E125

EXAM/TR (10)

1E126

EXAM/TR (11)

1E128

EXAM/TR (12)

1E130

EXAM/TR (18)

1E105

CORRIDOR

1E101

ED PASSAGE

1E132

NURSE STA

1E120

NURSE STA

1E110

EMT STOR

1S117

RISER RM

1S118

CORRIDOR

1E141

CORRIDOR

1E118

CORRIDOR

1E108

SEC

1E107

B

B B B B B B B B B A B B B B

BB

B

B

BA

B

B

B

B B

B

A

B

B

B

B B A B B B B

B

B

B

B

18.4 19.1 20.5

F.3

5.1

6.1

HH

FF5

GG

GG3

5.3

C2

C1

B

B

B

A

B

C2

F

D

J

D

J

E

E

E

F

F

F

J

J

K

K

L

L

VERNON E

ROSAMOND

No. 004634

S T A

T

E

OF NEW

MEX

IC

O

R E

G

IST ERED ARCH

IT

E C

T

R

VI

H

P

S

N I

D

C E

I

A

A N

HE TL H

S

E

E

H

N M

E

A R

P

T O

F T

C D

SU

S

A

E

TAE L &H

N V

I S

E R

U M

A H

A

B

C

D

1 2 3 4 5

1 2 3 4 5

Sheet Number:

Sheet Title:

Checked By:

Drawn By:

Scale:

Project No:

Issue Date:

Consultants:

JOHNSON SMITTHIPONG &

ROSAMOND ASSOCIATES, INC.

5210 E Williams Cir Ste 600 Tucson, AZ 85711

(520) 547-7904 www.jsra.com

U. S.

DEPARTMENT OF

HEALTH AND

HUMAN SERVICES

INDIAN HEALTH SERVICE

NAVAJO AREA OFFICE

E

/2

/2

:1

:0

A

M

A u to d e s k D o c s /2

-0

I H

S I

D

IQ

G

IM

C E

D R e n o

P h v

/2

-0

A rc h G

IM

C

E D

P H

.r v t

As indicated

A602

SIGN SCHEDULE

HARGREAVES

PARKER

21-070

1/2/23

IFC Set

GIMC EMERGENCY

DEPT. PHASE 2

516 East Nizhoni Boulevard, Gallup, NM 87301

1/2/23

3" = 1'-0"A SIGN TYPE A

3" = 1'-0"B SIGN TYPE B

1 1/2" = 1'-0"C1 SIGN TYPE C1

1 1/2" = 1'-0"C2 SIGN TYPE C2

3/4" = 1'-0"D SIGN TYPE D

3" = 1'-0"E SIGN TYPE E

3" = 1'-0"F SIGN TYPE F

3" = 1'-0"G SIGN TYPE G

3/4" = 1'-0"J SIGN TYPE J

3/4" = 1'-0"K SIGN TYPE K

3/4" = 1'-0"L SIGN TYPE L

1/4" = 1'-0"

SIGN LOCATION DETAIL (TYP.)

1/8" = 1'-0"1 SIGNAGE PLAN - FIRST FLOOR ED

SIGN SCHEDULE

Room # Room Name Sign Type Sign # Sign Verbiage

1E102 EQ STOR B 1E102 STORAGE CLOSET

1E103 COR 1E103

1E104 EXAM/TR (01) B 1E104 TRIAGE ROOM 02

1E105 EXAM/TR (18) B 1E105 EXAM ROOM 15

1E106 EXAM/TR (02) B 1E106 TRIAGE ROOM 01

1E107 SEC 1E107 SECURITY

1E109 EXAM/TR (03) B 1E109 EXAM ROOM 01

1E110 NURSE STA 1E110 TEAM ROOM

1E111 EXAM/TR (04) B 1E111 EXAM ROOM 02

1E112 ALCOVE XRAY 1E112

1E113 EXAM/TR (05) B 1E113 EXAM ROOM 03

1E115 EXAM/TR (06) B 1E115 EXAM ROOM 04

1E116 ELEC B 1E116 ELECTRICAL CLOSET

1E117 EXAM/TR (07) B 1E117 EXAM ROOM 05

1E119 EXAM/TR (08) B 1E119 EXAM ROOM 06

1E120 NURSE STA 1E120 TEAM ROOM

1E121 EXAM/TR (09) B 1E121 EXAM ROOM 07

1E123 TOILET PAT A 1E123 PATIENT RESTROOM

1E124 HSKP B 1E124 HOUSEKEEPING CLOSET

1E125 STOR 1E125 STORAGE CLOSET

1E126 EXAM/TR (10) B 1E126 EXAM ROOM 08

1E127A ACLOVE EAST 1E127A

1E128 EXAM/TR (11) B 1E128 EXAM ROOM 09

1E129 IT 1E129 IT CLOSET

1E130 EXAM/TR (12) B 1E130 SECRETARY/REGISTRATION

1E131 UTIL SOIL B 1E131 SOILED UTILITY ROOM

1E132 TOILET PAT A 1E132 STAFF RESTROOM

1E133 WAITING (45) B 1E133 BREAKROOM

1E134 REC B 1E134 OBSERVATION BED 02

1E135 VEND 1E135

1E136 TRIAGE 01 B 1E136 EXAM ROOM 11

1E137 TRIAGE 01 B 1E137 OBSERVATION BED 01

1E138 EXAM/TR (14) B 1E138 EXAM ROOM 12

1E139 TOILET PAT A 1E139 PATIENT RESTROOM

1E140 MED B 1E140 EXAM ROOM 13

1E142 TRAUMA 02 (16) B 1E142 TRAMA ROOM 02

1E143 EXAM/TR (13) B 1E143 EXAM ROOM 10

1E144 ANTE 1E144

1E145 DIETARY B 1E145 DIETARY

1E146 TRAUMA 01 (17) B 1E146 TRAMA ROOM 01

1E147 UTIL CLEAN B 1E147 CLEAN UTILITY ROOM

1E151 AMBULANCE ENT B 1E151 AMBULANCE ENTRANCE

1E153 ISO(15) B 1E153 MEDICATION ROOM

1E160 TLT/SHR A 1E160 RESTROOM/SHOWER

1E161 C.LINEN B 1E161 I.T. CLOSET

1E255 RAD B 1E255 RADIOLOGY

1S100 REGISTRATION B 1S100 PATIENT REGISTRATION

1S101 BENE COORD B 1S101 BENEFITS COORDINATOR

1S102 BEREAVMENT B 1S102 BREAVEMENT

1S104 SCN ASST B 1S104 ASCN ASSISTANT

1S105 ED MED CHIEF B 1S105 ED MEDICAL CHIEF

1S106 PAT REG SUP B 1S106 PATIENT REGISTRATION SUPERVISOR

1S109 SCN B 1S109 SCN OFFICE

1S110 STAFF RR 1S110 OBSERVATION 01

1S111 OBSERV (21) B 1S111 OBSERVATION 02

1S112 OBSERV (20) 1S112 OBSERVATION 03

1S114 ALCOVE 1S114 ALCOVE

1S115 LOCKERS B 1S115 EQUIPMENT STORAGE

1S116 STAFF RR B 1S116 STAFF RESTROOM

1S117 EMT STOR G 1S117 EMT STORAGE

1S118 RISER RM 1S118 RISER ROOM

No. Date Description

3 1/24/24 RFI Response

© Copyright 2013, CSI, 110 South Union St., Suite 100, Alexandria, VA 22314

Page ___ of ___ Form Version: January 2013 CSI Form 1.5C

SUBSTITUTION

REQUEST

(During the Bidding/Negotiating Stage)

Project:

To:

Re:

Substitution Request Number:

From:

Date:

A/E Project Number:

Contract For:

Specification Title:

Section: Page:

Description:

Article/Paragraph:

Proposed Substitution:

Manufacturer: Address: Phone:

Trade Name: Model No.:

Attached data includes product description, specifications, drawings, photographs, and performance and test data adequate for evaluation of the request; applicable portions of the data are clearly identified.

Attached data also includes a description of changes to the Contract Documents that the proposed substitution will require for its proper installation.

The Undersigned certifies:

• Proposed substitution has been fully investigated and determined to be equal or superior in all respects to specified product.

• Same warranty will be furnished for proposed substitution as for specified product.

• Same maintenance service and source of replacement parts, as applicable, is available.

• Proposed substitution will have no adverse effect on other trades and will not affect or delay progress schedule.

• Proposed substitution does not affect dimensions and functional clearances.

• Payment will be made for changes to building design, including A/E design, detailing, and construction costs caused by the substitution.

Submitted by:

Signed by:

Firm:

Address:

Telephone:

A/E’s REVIEW AND ACTION

☐ Substitution approved - Make submittals in accordance with Specification Section 01 25 00 Substitution Procedures.

☐ Substitution approved as noted - Make submittals in accordance with Specification Section 01 25 00 Substitution Procedures.

☐ Substitution rejected - Use specified materials.

☐ Substitution Request received too late - Use specified materials.

Signed by: Date:

Supporting Data Attached: ☐ Drawings ☐ Product Data ☐ Samples ☐ Tests ☐ Reports ☐

Tony.M Typewritten Text

GIMC EMERGENCY

DEPT. PHASE 2

Tony.M Typewritten Text

JOHNSON SMITTHIPONG &

ROSAMOND ASSOCIATES, INC.

Tony.M Typewritten Text

SOLID PHENOLIC LOCKERS

Tony.M Typewritten Text 105100

Tony.M Typewritten Text

Tony.M Typewritten Text

2.1 A

Tony.M Typewritten Text Locker manufacturers

Tony.M Typewritten Text

SUMMIT PHENOLIC LOCKERS

Tony.M Typewritten Text

SUMMIT LOCKERS

Tony.M Typewritten Text 138 McLeod Road Columbia, SC 29203

Tony.M Typewritten Text

(803) 403-8816

Tony.M Typewritten Text Tony Menka

Tony.M Typewritten Text Tony Menka

Tony.M Typewritten Text Norcon of New Mexico

Tony.M Typewritten Text 8437 Washington Pl NE b, Albuquerque, NM 87113

Tony.M Typewritten Text 505-343-8801

Tony.M Typewritten Text x

Tony.M Typewritten Text x

Tony.M Typewritten Text Norcon of New Mexico

Tony.M Typewritten Text 1/18/24

Tony.M Typewritten Text 21-070

SUMMIT LOCKERS PHENOLIC LOCKER

803-403-8816 | WWW.SUMMITLOCKERS.COM | INFO@SUMMITLOCKERS.COM

SUMMIT LOCKERS, INC. - 138 MCLEOD ROAD, COLUMBIA, SC 29203

Mortised Joints Mortise and tenon joints lock pieces together using stainless steel screws for superior strength and durability.

Ventilation Our lockers are designed with ventilation in mind with space around the doors to provide multi-directional ventilation.

Overlay Doors

Full sized / overlay doors increase the usable size of each locker for optimal usage.

Hygienic

Non-porous surfaces which make Summit's lockers safe and easy to clean.

Completely Customizable | Durable | Low Maintenance | Luxurious Look

Water Resistant

Summit Standard Phenolic Locker

Construction Mortise and Tenon Joints Full Overlay Doors Stainless Steel Fasteners Multi - Directional Ventilation

Material Thickness Top, Bottom & Shelves – White – 3/8“ Sides & Backs – White – 5/16“ Doors & Trim – Std. Colors – 1/2"

Sizes Height - 60”, 72”, 84” Width - 12”, 15”, 18”, 20” Depth – 12”, 15”, 18”, 20”

Hinges Concealed 6-Knuckle Stainless Steel

Lock Hasp for padlock

Fire Rating Class B

Base Not Included

Top Flat-Unfinished: White

Standard Configurations

1-Tier 2-Tier

3-Tier 4-Tier

5-Tier 6-Tier Z-Tier

INNOVATIVE LOCKERS

FOR YOUR NEXT PROJECT, PLEASE CALL 803-403-8816,

YOU MAY ALSO EMAIL YOUR QUESTIONS TO INFO@SUMMITLOCKERS.COM

Material Thickness 3/8” sides and shelves 3/8” sides and ½” shelves 1/2” sides and shelves

Hinges 180° Hinge (ADA Compliant) Continuous Stainless Steel Euro Hinge Soft-Close Hinges

Fire Rating Class A

Top Sloped Flat Finished Front Facia

Base Adjustable Base w/ Toe Kick Integral Base

Don't see your option listed? Just ask.

All locker orders are tailored to fit your needs.

Sizes Custom sizes available upon request.

Lock Vendors DigiLock® Lowe & Fletcher®

CODELOCKS® OMJAR®

ZEPHYR Lock® Gantner® Master Lock®

Color Custom Color Interior Through-Color Phenolic

Other Logo Engraving Through Door Ventilation Stay Closed Door Magnets Stainless Steel Coat Rod Shoulder pad/Helmet Rack USB Outlets LED Lighting

Phenolic Locker Customizations

Your home for innovation www.summitlockers.com | (803)403-8816 | info@summitlockers.com

Since opening our doors in 2011, Summit has tripled our production capacity and shipped to over 2,000 customers in all 50 states! We are dedicated to working with owners, architects, specialty companies, contractors, and installers to ensure that all your locker projects are a success.

Summit was founded on a simple premise that customers need durable lockers and a dependable company to partner with; and we were right.

WHO WE ARE

Superior Design Premium Materials & Superior Durability

To build a better locker, Summit chose to build our lockers with phenolic panels, mortised joints, and stainless steel fasteners in lieu of butt joints, welds, or pop rivets. Our shelves feature tenons that provide strength to support heavy loads resulting in a stronger, more durable, and rigid locker. These lockers are built with full, overlay doors and hidden ventilation to improve access, appearance, storage capacity, and ventilation.

Mortised Joints

Summit Locker's mortise and tenon joints lock pieces together using stainless steel screws for superior strength and durability.

Ventilation

Our lockers are designed with ventilation in mind with space around the doors to provide multi-directional ventilation.

Overlay Doors

Our full sized / overlay doors increase the usable size of each locker for optimal usage.

Hygienic

Our lockers are composed of non-porous surfaces which make them safe and easy to clean.

Water Resistant

Water Resistant & Durable Phenolic lockers

Summit Phenolic lockers combine the appeal of wooden lockers with low maintenance and superior durability. Phenolic lockers are perfect for high traffic, as well as high moisture areas.

Athletic Lockers

Our athletic lockers provide a competitive advantage by combining strength, durability, low maintenance, and custom designs for professional, collegiate, and high school teams.

t h e l o o k o f s u c c e s s

High Density Polyethylene (HDPE) lockers have through- color panels and perform well in high moisture areas. Numerous sizes and styles make these lockers suitable for all facilities.

HDPE Lockers Durable Solid Plastic

Benches

Cubbies Summit provides cubbies in all sizes and configurations. From small mail cubbies all the way to equipment storage, we can meet your needs.

Summit provides locker room benches in Solid Phenolic, Solid Plastic (HDPE), and hardwood to meet customer's design needs including ADA compliant options. We offer a wide variety of options to mount your benches.

Specialty Products Cabinets

Pass-Through lockers

Equipment Lockers

Storage Boxes

Cubby Benches/ integral bench

Summit's Solid Phenolic Specialty products can be customized to fit any project. We offer 300+ color options, door pulls, locks, color coated tags, magnetic catches, and custom interior options.

Locks

Phenolic

**Visit summitlockers.com for more information on colors and Locks

Solid phenolic lockers have a nonporous, easy to clean surface that is water, mold, and mildew resistant.

Summit Lockers has over 300 color options available to choose from.

HDPE

HDPE lockers have an orange peel, nonporous, and easy to clean surface. Our lockers are water, mold, and mildew resistant.

Summit manufactures cabinets and lockers while working with industry leading lock suppliers to meet your security needs. Here are a few companies we work with:

GOING GREEN

INNOVATIVE LOCKER ROOM SOLUTIONS

Durable & Long Lasting

Summit Lockers are made in the U.S.A.

using environmentally friendly materials.

We use modern high-precision equipment to provide consistent and top quality products. Our design and manufacturing capabilities enables us to create a variety of custom products.

Sustainability

Summit Lockers addresses sustainability through the production of durable lockers that are manufactured with environmentally aware components.

The result is a longer lasting locker that uses less natural resources.

As an environmentally friendly company, our lockers are made from recycled materials in several ranges to qualify for GREENGUARD indoor air quality and LEED certification.

Contact us (803)403-8816 info@summitlockers.com www.summitlockers.com

138 McLeod Road

Columbia, SC 29203

756- Natural Maple 758- Blossom Cherrywood 3712- Walnut Butcherblock 8842- Weathered Ash 8844- Aged Ash

9012- Ebony 9283- Walnut Riftwood 9312- Planked Urban Oak 9484- Oxidized Beamwood 909- Black

912- Storm 927- Folkstone 928- Mouse 949- White 961- Fog

969- Navy Blue 5342- Earth 7197- Dover White 8751- Mojave 8793- Green Slate

515- Graphite Grafix 3709- Brushed Iron 3711- Slate Noir 3720- White Pearl Cascade 5880- Earthen Warp

6307- Burnt Strand 6696- Carrara Bianco 6697- Argento Romano 7732- Butterum Granite 8826- Neutral Twill

803-403-8816 | WWW.SUMMITLOCKERS.COM | INFO@SUMMITLOCKERS.COM

SUMMIT LOCKERS, INC. - 138 MCLEOD ROAD, COLUMBIA, SC 29203

FORMICA PHENOLIC

Completely Customizable | Durable | Low Maintenance | Luxurious Look

STANDARD HASP BAR LOCK

803-403-8816 | WWW.SUMMITLOCKERS.COM | INFO@SUMMITLOCKERS.COM

SUMMIT LOCKERS, INC. - 138 MCLEOD ROAD, COLUMBIA, SC 29203

The standard locking option for Summit Phenolic Lockers is a through door mounted 11 gauge stainless steel hasp bar for end-user supplied padlocks. The hasp bar is secured to the locker side panels using theft proof stainless steel fasteners and protrudes through the door for ultimate security.

On the front of the door we provide a reverse side engraved plastic ID tag and door pull. The ID tag is reverse side engraved with ½” tall numbers so that the numbers will not deteriorate or collect dirt. The tag also provides protection from the padlock hitting the door.

- ID Plate is attached with double sided adhesive tape.

*ALTERNATIVE LOCKING MECHANISMS AND ID TAGS/DOOR PULLS ARE AVAILABLE UPON REQUEST*

FOR YOUR NEXT PROJECT, PLEASE CALL 803-403-8816,

YOU MAY ALSO EMAIL YOUR QUESTIONS TO INFO@SUMMITLOCKERS.COM

Options

Material Thickness 3/8” sides and shelves 3/8” sides and ½” shelves 1/2” sides and shelves

Sizes Custom sizes available upon request.

Hinges 180° Hinge/ADA Compliant Continuous Stainless Steel Euro Hinge

Lock Vendors DigiLock® Lowe & Fletcher®

CODELOCKS® OMJAR®

ZEPHYR Lock® Gantner® Master Lock®

Fire Rating Class A

Base Adjustable Base with Toe Kick Integral Base

Top Sloped Flat Finished Front Facial

Color Custom Color Interior Through-Color Phenolic

Other Logo Engraving Through Door Ventilation Stay Closed Door Magnets Stainless Steel Coat Rod

Mortise and Tenon Joints Full Overlay Doors Stainless Steel Fasteners Stainless Steel Coat Hooks Multi - Directional Ventilation

Top, Bottom & Shelves – White – 3/8“ Sides & Backs – White – 5/16“ Doors & Trim – Std. Colors – 1/2"

Height - 60”, 72”, 84” Width - 12”, 15”, 18”, 20” Depth – 12”, 15”, 18”, 20”

Concealed 6-Knuckle Stainless Steel

Hasp for padlock

Unfinished - White

Standard Details

Construction

Material Thickness

Sizes

Hinges

Lock

Fire Rating Class B

Base Not Included

Top

Don't see your option listed? Just ask. All locker orders are tailored to fit your needs.

Amend No. Item # Date Submitted

Question Type (Technical or

Admin) Question Response

Date

Response Responded By

A00002 1 N/A Admin SEE RESPONSE TO BRAND NAME PROPOSALS 12/27/2023

Proposals shall incorporate all brand names identified in the solicitation or approved "equal" incorporated via solicitation amendment. If proposing an "equal" not approved during the solicitation process, contractors shall submit a separate price proposal, in addition to the price proposal for the brand names identified in the solicitation. The price proposal for "equal" items shall include all information requested on CSI Form 13.1A

Contracting

A0001 2 12/20/2023 Technical How many CAT 6A ports shall be installed per TELE/DATA drop? Is it two (2), three (3) or four (4)?

12/21/2023 Provide four (4) ports with six (6) port stainless steel coverplates with two (2) blanks for non-ported outlets for all Tele/Data outlets. Design Firm

A0001 3 12/20/2023 Technical

Are the stainless-steel cover plates to be four (4) port or six (6) cover plates?

On the drawings/plans page E151 General Notes Section B states: “All tele/data outlets shall be (4) port with (6) port cover plates.”

Keyed notes section 3 states: “Provide (2) port voip data outlets, typical unless noted otherwise. Installation shall be complete with (1) 1''c stubbed from data outlet to basket cable tray. Conduits shall terminate at cable tray with a nylon bushing. Provide (2) cat6 plenum rated cables from data ports to patch panel within data management rack within it 1e129. All cat6 cabling shall be terminated at each data port and at patch panel. All cat6 cables shall be tested and certified.”

On the Drawings/plans page E001 Tele/Data Legend indicates a “Wall mounted data Outlet – With 3 Data drops” for the indicated icon of a black triangle with a center fill of all white.

In the specifications document page 1474 (271510-5) section 2.3 Modular Jacks part B states:

“Provide stainless steel four port keystone compatible faceplates. Provide blank closures where required. Comply with all Owner requirements for faceplate configurations.”

12/21/2023

Refer to response 1 above.

Design Firm

A0001 4 12/20/2023 Technical

The Specifications documentation is asking for this specific warranty while also naming CommScope and Leviton to be used in separate portions of the system. In order to obtain a 25-year warranty, the entire cabling installation will need to consist of products from the same manufacturer, end-to-end, and a certified installer to sign off on the project.

For this project a Siemons certification or CommScope certification can be obtained. Shall we submit the bid for the project with the 25-year warranty or bid as specified which would not qualify for the 25 year warranty?

Specifications document page 1491 and 1492 (280513-3 and 280513-3 states:

2.3 UTP CABLE

A.Manufacturers: Subject to compliance with requirements, provide products by one of the following:

1.CommScope, Inc.

2.4UTP CABLE HARDWARE

A.Manufacturers: Subject to compliance with requirements, provide products by one of the following:

1.Leviton Commercial Networks Division.

Specifications document page 1473 (271510-4) states:

1.6WARRANTY

A.The Contractor shall warranty all material, equipment, and work performed under this contract for one (1) year from date of acceptance.

The full cost of maintenance, labor, and materials to correct any defect shall be included in this bid.

B.Provide manufacturer network infrastructure solution 25 year extended product warranty.

C.Submittal shall include documentation and certification from the manufacturer regarding authorization to provide the manufacturer’s 25 year extended product warranty.

12/21/2023

Provide a 1 year warranty.

Design Firm

A0002 5 12/20/2023 Technical

The specification is asking for a 25-pair utility feed although this does not seem to be depicted in the plans/drawing and the requested cable type does not exist. Can we please have clarification regarding this specific request.

2.2 CABLING

B.Utility feed and backbone copper cabling shall be 25 pair, CommScope CAT-6A, 550 Mhz, plenum rated cable (or rated as required for feed and entrance), or as directed by Owner.

1.The Contractor shall coordinate existing copper feeds with the Owner prior to bidding the project regarding what may be re-used and what must be replaced.

12/21/2023

The 25 pair cable (24 AWG, MEGAPIC-NF OSP Broadband Backbone CAT5, Solid Annealed Copper, Polymer Coated Corrugated Aluminum Tape Sheild) should be installed from GW-28 to New IDF at ED Expansion.

IHS

Design Firm

A0002 6 12/21/2023 Technical 271500 Horizontal Cabling: 271500 Horizontal Cabling:

Can you provide details on the existing horizontal cabling system? (e.g., cable types, specifications) 12/22/2023

.All 24 AWG Copper Cables (24 AWG, MEGAPIC-NF OSP Broadband Backbone CAT5, Solid Annealed Copper, Polymer Coated Corrugated Aluminum Tape Sheild) are terminated from D-Mark (GW28) to the perposed IDF locations.

IHS/GIMC

A0002 7 12/21/2023 Technical 271500 Horizontal Cabling: 271500 Horizontal Cabling: Is the owner open to considering a BerkTek & Leviton cabling solution with 20 year manufacturer warranty? 12/22/2023

As long as the copper cables are Sheilded with Polymer Coated Corrugate Tape. Cables need to be grounded/sheilded due to signal interferences. IHS/GIMC

A0002 8 12/21/2023 Technical 271500 Horizontal Cabling: Is the owner intending to use existing backbone cable, or is any new backbone cable or fiber required. If so, please provide specifications. 12/22/2023

Yes, New Copper (See Cable required in ITEM#4) and New Fiber (12 strand single-mode OS/2, Duplex) terminated at each end with a 1RU Rack Mount and Cira Telecom 25 pair Lightning Protected 110 Block. IHS/GIMC

A0002 9 12/21/2023 Technical 275116 Public Address System: Please provide the specifications for the existing Public Address system including the brand and models?

12/21/2023 BOGEN Paging/Intercom System

IHS/GIMC

A0002 10 12/21/2023 Technical 275116 Public Address System: Is the existing system capable of handling the additional speakers specified for this project, or will a new headend be required for the new area? 12/22/2023

The existing Bogen Paging System will handle speakers for this project but all overhead speakers will need to terminate in the IDF Room. IHS/GIMC

A0002 11 12/21/2023 Technical 275116 Public Address System: Are there any specific features or capabilities that we should consider in matching the existing system?

12/22/2023 The ceiling speakers should be drop-in ceiling speakers by Bogen.

IHS/GIMC

A0002 12 12/21/2023 Technical 275223 Nurse Call/Code Blue: Could you provide specifications for the current nurse call/Code Blue system, including the manufacturer and model? 12/21/2023

Hill-Rom/Baxter (Voalte) Nurse Call system

IHS/GIMC

A0002 13 12/21/2023 Technical 275223 Nurse Call/Code Blue:Is the existing Nurse call system capable of handling the expansion required for the new areas? 12/22/2023 Yes, Hill-Rom/Baxter (Voalte) will need to installed by a certified Hill-Rom Installer. IHS/GIMC A0002 14 12/21/2023 Technical 275223 Nurse Call/Code Blue: Is the owner open to a different nurse call system 12/22/2023 No, GIMC is only using Hill-Rom Voalte System IHS/GIMC

A0002 15 12/21/2023 Technical 281300 Access Control (Controller, Card Readers): Please provide the brand and model of access control equipment that is currently implemented? 12/21/2023

Tyco Software House (C-Cure 9000 v2.9)

IHS/GIMC

A0002 16 12/21/2023 Technical 281300 Access Control (Controller, Card Readers): Is the system capable of handling the new access control equipment required for the new areas? 12/22/2023

We (GIMC) will need to verify with current contractor on new installation and warranty.

IHS/GIMC

A0002 17 12/21/2023 Technical 282300 Video Surveillance (Interior and Exterior): Can you share details on the existing video surveillance system, including Video Management system, camera types and specifications? 12/21/2023

ExacqVision Video Management – Professional with Hanwha Techwin Camera’s (In & Outdoor, Day & Night Camera’s) IHS/GIMC

A0002 18 12/21/2023 Technical 282300 Video Surveillance (Interior and Exterior): What are the preferences for capabilities and features? 12/22/2023 Each indoor camera (4M Network IR Dome Camera) 4 mega pixel IHS/GIMC

A0002 19 12/21/2023 Technical 282300 Video Surveillance (Interior and Exterior): Will the current NVR be used to connect to the new cameras, or will a new NVR be required? If the existing NVR is to be used, please provide the existing storage capacity and number of cameras connected. 12/22/2023

The new cameras will need to be connected/configured to our current NVR System.

IHS/GIMC

A0002 20 12/21/2023 Technical 282300 Video Surveillance (Interior and Exterior): If a new NRV is required, please indicate what the desired retainage is for stored video – number of days or months, and what frame rate is expected. 12/22/2023

Use current NVR but licenses maybe required for configuration of new cameras.

IHS/GIMC

A0001 21 12/21/2023 Technical Low Voltage Cabling Demolition Responsibility: Who is responsible for the demolition of existing low voltage cabling and devices?

12/21/2023 Electrical contractor.

Design Firm

A0001 22 12/21/2023 Technical What is the existing Fire Alarm system that needs to be matched?

12/21/2023 Siemens Fire Alarm Panel – Model: FHD2007-R3 (THIS IS MAINTAINED BY GIMC-BOILER DEPT.)

IHS/GIMC

A0004 23 12/29/2023 Technical

Ground Floor Demo Plans sheet A112, and Ground Floor Plan sheet A121:

At the existing thick wall north of GL F.3, keynote 01 24 indicates infilling of existing window openings between GL 19 to 20.6 with 2 hour construction. Neither plan seems to define where those windows are removed or are to be infilled. Keynote 01 24 also appears on this wall west of GL 19 which is outside of the GL 19 to 20.6 parameters described in the keynote. Please define how the 2 hour separation is to be constructed. Is this two layers of 8” CMU? If so, can we get a detail of how this is to be constructed? The unnamed area along GL F.3, and roughly between GL 21 to 22, appears to be completely covered by the First Floor and has no access. Is this area filled with dirt? Keynote 02 19 indicates removal of existing windows and infill with CMU. Please provide detail of the CMU infill.

1/8/2024

Refer to attached detail Window In-Fill Detail in Concrete Wall.pdf - Attachment 1, Amendment 4

Design Firm

A0004 24 12/29/2023 Technical Ground Floor Plan sheet A121:

Keynote 03 41 refers to Structural Detail 14/S210 for reinforcing at infill of temporary stair egress, but there are no structural drawings provided.

1/8/2024 Refer to attached In-Fill Detail in Concrete Wall.pdf - Attachment 2, Amendment 4

Design Firm

A0004 25 12/29/2023 Technical Elevations sheet A201, and Details D1 and D2 on sheet A405:

There is no callout for the wall finish below Level 1 (0”), and extending down the stairs to entry door GE50B. Please clarify. 1/8/2024

Exposed concrete. Finish shall be “patch & rub” smooth monochromatic concrete.

Design Firm

A0007 26 1/23/2024 Technical Sign types C1, C2, D, E, F, J, K, L not seen on sign schedule or sign plan. Please confirm these signs are not needed for this phase. 1/24/2024

Yes, the sign details on A602 are needed for the complete sign package. Refer to the attached drawing A603r3 for all of the sign locations. (See Amendment 7) Design Firm

B05 Amendment 7
SF30 Continuation Page
B03 Site Visit Roster Jan 19
A602r3 - Sign Schedule
Sheets
A602 - SIGN SCHEDULE
CSI Request Sheet Norcon New Mexico
B04 RFI Response 1-26

File details come from the government source that posted it. Updated .