B05 Amendment 7.pdf
PDF 4 MB Posted
- Solicitation number
- 75H70124R00012
About this file
This is a solicitation notice for a construction project to renovate and expand the Gallup Indian Medical Center Emergency Department in Gallup, New Mexico. The project scope includes renovating approximately 9,671 gross square feet of existing and new space in the first floor east wing to alleviate current space deficiencies. Site work and ambulance entrance driveway work are also required. The estimated construction value is between $5-10 million. The period of performance is 550 calendar days from notice to proceed using firm fixed price contracting. The solicitation will use request for proposal procedures according to FAR Parts 15 and 36. Proposals are due by the date and time specified in the SF1442. Evaluation will use the tradeoff process stated in FAR 15.101-1. The responsible agency is the Indian Health Service. Offerors must register in SAM and check for amendments frequently on the listed website.
View the file
Other files
Show all 22
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:
(a) By completing items 8 and 15, and returning or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
E. IMPORTANT: Contractor is not is required to sign this document and return copies to the issuing office.
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT 1. CONTRACT ID CODE
2. AMENDMENT/MODIFICATION NUMBER 3. EFFECTIVE DATE 4. REQUISITION/PURCHASE REQUISITION NUMBER 5. PROJECT NUMBER (If applicable)
7. ADMINISTERED BY (If other than Item 6) CODE
STANDARD FORM 30 (REV. 11/2016)
Prescribed by GSA FAR (48 CFR) 53.243
FACILITY CODE
9A. AMENDMENT OF SOLICITATION NUMBER
9B. DATED (SEE ITEM 11)
10A. MODIFICATION OF CONTRACT/ORDER NUMBER
10B. DATED (SEE ITEM 13)
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers is extended. is not extended.
12. ACCOUNTING AND APPROPRIATION DATA (If required) copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NUMBER AS DESCRIBED IN ITEM 14.
CHECK ONE A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER
NUMBER IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation data, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15C. DATE SIGNED
15A. NAME AND TITLE OF SIGNER (Type or print)
16C. DATE SIGNED
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
PAGE OF PAGES
6. ISSUED BY CODE
8. NAME AND ADDRESS OF CONTRACTOR (Number, street, county, State and ZIP Code) (X)
CODE
15B. CONTRACTOR/OFFEROR
(Signature of person authorized to sign)
16B. UNITED STATES OF AMERICA
(Signature of Contracting Officer)
Previous edition unusable
A00007
Andrew Hart, Contracting Officer
See SF30 Continuation Page.
Indian Health Service - DES Seattle 701 5th Avenue, Suite 1600 Seattle, WA 98104
See Item 6
75H70124R00012
NA21GA099H8
1 25
01/24/2024
11/29/2023
SF30 Continuation Page 2
The purpose of amendment 7 to solicitation 75H70124R00012 is the following:
1. Incorporate site visit roster dated 1/19/2024.
2. Incorporate sign schedule A602 revision 3 dated 1/24/2024.
3. Incorporate substitution request dated 1/18/2024. This request (brand name) is in addition to the brand name identified in the project documents.
4. Incorporate RFI responses 1-26.
5. The offer due date remains unchanged at 12:00pm Pacific time on 2/1/2024.
6. All other terms and conditions remain unchanged.
UP
DN
R E
F
7 7/8"
7 7/8"
BLACK PLASTIC
END CAP
RAISED
PICTOGRAMS
ON ACRYLIC
INSERT.
1/4" HIGH
BRAILLE ON
ACRYLIC
INSERT, RAISED
1/32" 1
/8
/4
/8
BLACK
PLASTIC
END CAP
ALUMINUM
FRAME
BLACK
PLASTIC
END CAP
PLAN
FRONT ELEVATIONSIDE ELEVATION
PATIENT RESTROOM
GRAPHICS AND
TEXT SHALL BE
A COMPUTER
GENERATED
TRANSPARENCY
INSERT BEHIND
ACRYLIC
FINAL VERBIAGE
TO BE
DETERMINED BY
CONTRACTING
OFFICER
/8
/4
/8
5 7/8"
5 7/8"
/8
/8
"1 /4
/8
/8
/4
/8
/8
BLACK PLASTIC
END CAP
RAISED CHARACTERS ON
ACRYLIC INSERT,
MINIMUM HEIGHT SHALL
BE 5/8" HIGH
1/4" HIGH BRAILLE ON
ACRYLIC INSERT,
RAISED 1/32"
GRAPHICS AND TEXT
SHALL BE A COMPUTER
GENERATED
TRANSPARENCY
INSERT BEHIND
ACRYLIC
/8
/4
/8
BLACK
PLASTIC
END CAP
ALUMINUM
FRAME
BLACK
PLASTIC
END CAP
PLAN
FRONT ELEVATIONSIDE ELEVATION
1E225
SOILED UTILITY
FINAL VERBIAGE
TO BE
DETERMINED BY
CONTRACTING
OFFICER
ROOM
1'-3 3/4"
1'-3 3/4"
PLAN
FRONT ELEVATION
/2 "2
/2
" 2
/2 "2
/2
" 2
/2 "2
/2
" 2
/2
/2
GRAPHICS AND
TEXT SHALL BE A
COMPUTER
GENERATED
TRANSPARENCY
INSERT BEHIND
ACRYLIC
BLACK
PLASTIC END
CAP
/8
'-1
/2
/8
ALUMINU
M FRAME
BLACK
PLASTI
C END
CAP
SIDE ELEVATION
GRAPHICS AND
TEXT SHALL BE A
COMPUTER
GENERATED
TRANSPARENCY
INSERT BEHIND
ACRYLIC
FINAL VERBIAGE
AND DIRECTION
TO BE
DETERMINED BY
CONTRACTING
OFFICER
DIRECTORY
FIRST FLOOR
ULTRA SOUND
BLOOD LAB
RADIOLOGY
CORRESPONDENCE
MAMMOGRAM
DEXA SCAN
CT SCAN
1'-3 3/4"
FRONT ELEVATION
ED PATIENT REGISTRATION
ULTRA SOUND
BLOOD LAB
URGENT CARE CLINIC
/2 "2
/2
" 2
/2 "2
/2
" 2
/2 "2
/2
" 2
/2
/2
GRAPHICS AND
TEXT SHALL BE A
COMPUTER
GENERATED
TRANSPARENCY
INSERT BEHIND
ACRYLIC
BLACK
PLASTIC END
CAP
/8
'-1
/2
/8
ALUMINU
M FRAME
BLACK
PLASTI
C END
CAP
SIDE ELEVATION
GRAPHICS AND
TEXT SHALL BE A
COMPUTER
GENERATED
TRANSPARENCY
INSERT BEHIND
ACRYLIC
DIRECTORY
FIRST FLOOR
RADIOLOGY
CORRESPONDENCE
MAMMOGRAM
DEXA SCAN
CT SCAN
FINAL VERBIAGE
AND DIRECTION
TO BE
DETERMINED BY
CONTRACTING
OFFICER
1'-3 3/4"
PLAN
EMERGENCY EXIT ONLY 3
OF DOOR
BOTTOM OF LETTER
@ 5'-6" A.F.F.
RED VINYL DIE-CUT
LETTERS, ARIAL
FONT 75%
CHARACTER WIDTH.
FINAL VERBIAGE
TO BE
DETERMINED BY
CONTRACTING
OFFICER
NO SMOKING
NO FIREARMS
/2
/2
OF GLAZING
' A
F F
WHITE VINYL DIE-CUT
LETTERS
FINAL VERBIAGE
TO BE
DETERMINED BY
CONTRACTING
OFFICER
8 1/2"
8 1/2"
BLACK PLASTIC
END CAP
PLAN
FRONT ELEVATION
EXIT MAP
/8
/4
/8
BLACK
PLASTIC
END CAP
ALUMINUM
FRAME
BLACK
PLASTIC
END CAP
SIDE ELEVATION
RAISED
CHARACTERS
ON ACRYLIC
INSERT,
MINIMUM
HEIGHT SHALL
BE 5/8" HIGH.
1/4" HIGH
BRAILLE ON
ACRYLIC
INSERT, RAISED
1/32"
COMPUTER
GENERATED
GRAPHICS ON
PAPER BEHIND
TRANSPARENCY
/8
/8
/4
/8
6"
SOLID
ALUMINUM
SHEET
SURFACE APPLIED FLAT
GRAPHICS COLOR:
BLACK. MINIMUM HEIGHT
SHALL BE 5/8" HIGH.
SURFACE APPLIED
RAISED BRAILLE, 1/32"
MIN.
GRAPHICS AND TEXT
SHALL BE APPLIED
BAKED ENAMEL OR
POWDER COAT
SOLID
ALUMINUM
SHEET
FASTENER
S
PLAN
FRONT ELEVATIONSIDE ELEVATION
1S116
EMS
FINAL VERBIAGE
TO BE
DETERMINED BY
CONTRACTING
OFFICER
BACKGROUND COLOR:
WHITE.
/8
"5 /8
/4
/8
" 1
/4
/8
A B
O V
E G
R A
D E
'-0
STORAGE
1'-6"
'-0
PLAN
FRONT ELEVATION
FINAL VERBIAGE
TO BE
DETERMINED BY
CONTRACTING
OFFICER
BACKGROUND COLOR: WHITE
SURFACE APPLIED FLAT GRAPHICS
COLOR: RED.
SOLID ALUMINUM SHEET
GRAPHICS AND TEXT SHALL BE
APPLIED BAKED ENAMEL OR
POWDER COAT
FASTENER
S
A B
O V
E G
R A
D E
NO
SMOKING
R 3/8"
SURFACE APPLIED FLAT TEXT
COLOR: BLACK.
SURFACE APPLIED FLAT GRAPHIC
COLOR: BLACK.
2'-6"
'-4
PLAN
FRONT ELEVATION
SHORT TERM PARKING
FOR EMERGENCY &
LAW ENFORCEMENT
VEHICLES
FINAL VERBIAGE
TO BE
DETERMINED BY
CONTRACTING
OFFICER
BACKGROUND
COLOR: WHITE
" 1
"2 " 1
"2 " 1
"2
" SURFACE APPLIED
FLAT GRAPHICS
COLOR: BLACK.
R 3/8"
SOLID ALUMINUM
SHEET
GRAPHICS AND
TEXT SHALL BE
APPLIED BAKED
ENAMEL OR
POWDER COAT
FASTENER
S
A B
O V
E G
R A
2'-8"
'-6
PLAN
FRONT ELEVATION
SHUT OFF
YOUR
ENGINE
WHILE
PARKED
FINAL VERBIAGE
TO BE
DETERMINED BY
CONTRACTING
OFFICER
BACKGROUND
COLOR: WHITE
SURFACE APPLIED
FLAT GRAPHICS
COLOR: RED.
R 3/8"
SOLID ALUMINUM
SHEET
GRAPHICS AND
TEXT SHALL BE
APPLIED BAKED
ENAMEL OR
POWDER COAT
FASTENER
S
A B
O V
E G
R A
/2
'-0
A/B
NOTE: WHEN SIGN CANNOT BE IMMEDIATELY ADJACENT TO DOOR FRAME, MOUNT
ON SIDE WALL NEAR LEVER HANDLE. MOUNTING LOCATION SHALL BE SO THAT A
PERSON MAY APPROACH WITHIN 3 INCHES OF SIGNAGE WITHOUT INCOUNTERING
PROTRUDING OBJECTS OR STANDING WITHIN THE SWING OF A DOOR. SIGN
INSTALLER TO SUBMIT SHOP DRAWINGS SHOWING ACTUAL SIGN INSTALLATION
LOCATION.
4" TYP. 4" TYP.
A/B A/BC/F
15 16 17 18 19 20 21 22
AeAe
Be
B.1
F.1
G
H
G.5
FF
E
F
G.4
UC PASSAGE
1E254
RAD
1E255
CLOSET
1E256
'-6
Patient Waiting
1E35
STAIR EAST
1E95
South Corridor
1S148
ED MED CHIEF
1S105
SCN
1S109
BEREAVMENT
1S102
SCN ASST
1S104
PAT REG SUP
1S106
BENE COORD
1S101
REGISTRATION
1S100
CORRIDOR
1S103
CORRIDOR
1S108
AMBULANCE ENT
1E151
ISO(15)
1E153
LOCKERS
1S115
ALCOVE
1S114
STAFF RR
1S116
OBSERV (21)
1S111
OBSERV (20)
1S112
STAFF RR
1S110
C.LINEN
1E161
TLT/SHR
1E160 TRAUMA 01 (17)
1E146
TRAUMA 02 (16)
1E142
MED
1E140
EXAM/TR (14)
1E138
WAITING (45)
1E133
IT
1E129
UTIL SOIL
1E131
REC
1E134
TOILET PAT
1E132
CORRIDOR
1E127
TRIAGE 01
1E137
EXAM/TR (13)
1E143
HSKP
1E124
TOILET PAT
1E139
ELEC
1E116
DIETARY
1E145
UTIL CLEAN
1E147
EQ STOR
1E102
EXAM/TR (01)
1E104
EXAM/TR (02)
1E106
EXAM/TR (03)
1E109
EXAM/TR (04)
1E111
EXAM/TR (05)
1E113
EXAM/TR (06)
1E115
EXAM/TR (07)
1E117
EXAM/TR (08)
1E119
EXAM/TR (09)
1E121 TOILET PAT
1E123
STOR
1E125
EXAM/TR (10)
1E126
EXAM/TR (11)
1E128
EXAM/TR (12)
1E130
EXAM/TR (18)
1E105
CORRIDOR
1E101
ED PASSAGE
1E132
NURSE STA
1E120
NURSE STA
1E110
EMT STOR
1S117
RISER RM
1S118
CORRIDOR
1E141
CORRIDOR
1E118
CORRIDOR
1E108
SEC
1E107
B
B B B B B B B B B A B B B B
BB
B
B
BA
B
B
B
B B
B
A
B
B
B
B B A B B B B
B
B
B
B
18.4 19.1 20.5
F.3
5.1
6.1
HH
FF5
GG
GG3
5.3
C2
C1
B
B
B
A
B
C2
F
D
J
D
J
E
E
E
F
F
F
J
J
K
K
L
L
VERNON E
ROSAMOND
No. 004634
S T A
T
E
OF NEW
MEX
IC
O
R E
G
IST ERED ARCH
IT
E C
T
R
VI
H
P
S
N I
D
C E
I
A
A N
HE TL H
S
E
E
H
N M
E
A R
P
T O
F T
C D
SU
S
A
E
TAE L &H
N V
I S
E R
U M
A H
A
B
C
D
1 2 3 4 5
1 2 3 4 5
Sheet Number:
Sheet Title:
Checked By:
Drawn By:
Scale:
Project No:
Issue Date:
Consultants:
JOHNSON SMITTHIPONG &
ROSAMOND ASSOCIATES, INC.
5210 E Williams Cir Ste 600 Tucson, AZ 85711
(520) 547-7904 www.jsra.com
U. S.
DEPARTMENT OF
HEALTH AND
HUMAN SERVICES
INDIAN HEALTH SERVICE
NAVAJO AREA OFFICE
E
/2
/2
:1
:0
A
M
A u to d e s k D o c s /2
-0
I H
S I
D
IQ
G
IM
C E
D R e n o
P h v
/2
-0
A rc h G
IM
C
E D
P H
.r v t
As indicated
A602
SIGN SCHEDULE
HARGREAVES
PARKER
21-070
1/2/23
IFC Set
GIMC EMERGENCY
DEPT. PHASE 2
516 East Nizhoni Boulevard, Gallup, NM 87301
1/2/23
3" = 1'-0"A SIGN TYPE A
3" = 1'-0"B SIGN TYPE B
1 1/2" = 1'-0"C1 SIGN TYPE C1
1 1/2" = 1'-0"C2 SIGN TYPE C2
3/4" = 1'-0"D SIGN TYPE D
3" = 1'-0"E SIGN TYPE E
3" = 1'-0"F SIGN TYPE F
3" = 1'-0"G SIGN TYPE G
3/4" = 1'-0"J SIGN TYPE J
3/4" = 1'-0"K SIGN TYPE K
3/4" = 1'-0"L SIGN TYPE L
1/4" = 1'-0"
SIGN LOCATION DETAIL (TYP.)
1/8" = 1'-0"1 SIGNAGE PLAN - FIRST FLOOR ED
SIGN SCHEDULE
Room # Room Name Sign Type Sign # Sign Verbiage
1E102 EQ STOR B 1E102 STORAGE CLOSET
1E103 COR 1E103
1E104 EXAM/TR (01) B 1E104 TRIAGE ROOM 02
1E105 EXAM/TR (18) B 1E105 EXAM ROOM 15
1E106 EXAM/TR (02) B 1E106 TRIAGE ROOM 01
1E107 SEC 1E107 SECURITY
1E109 EXAM/TR (03) B 1E109 EXAM ROOM 01
1E110 NURSE STA 1E110 TEAM ROOM
1E111 EXAM/TR (04) B 1E111 EXAM ROOM 02
1E112 ALCOVE XRAY 1E112
1E113 EXAM/TR (05) B 1E113 EXAM ROOM 03
1E115 EXAM/TR (06) B 1E115 EXAM ROOM 04
1E116 ELEC B 1E116 ELECTRICAL CLOSET
1E117 EXAM/TR (07) B 1E117 EXAM ROOM 05
1E119 EXAM/TR (08) B 1E119 EXAM ROOM 06
1E120 NURSE STA 1E120 TEAM ROOM
1E121 EXAM/TR (09) B 1E121 EXAM ROOM 07
1E123 TOILET PAT A 1E123 PATIENT RESTROOM
1E124 HSKP B 1E124 HOUSEKEEPING CLOSET
1E125 STOR 1E125 STORAGE CLOSET
1E126 EXAM/TR (10) B 1E126 EXAM ROOM 08
1E127A ACLOVE EAST 1E127A
1E128 EXAM/TR (11) B 1E128 EXAM ROOM 09
1E129 IT 1E129 IT CLOSET
1E130 EXAM/TR (12) B 1E130 SECRETARY/REGISTRATION
1E131 UTIL SOIL B 1E131 SOILED UTILITY ROOM
1E132 TOILET PAT A 1E132 STAFF RESTROOM
1E133 WAITING (45) B 1E133 BREAKROOM
1E134 REC B 1E134 OBSERVATION BED 02
1E135 VEND 1E135
1E136 TRIAGE 01 B 1E136 EXAM ROOM 11
1E137 TRIAGE 01 B 1E137 OBSERVATION BED 01
1E138 EXAM/TR (14) B 1E138 EXAM ROOM 12
1E139 TOILET PAT A 1E139 PATIENT RESTROOM
1E140 MED B 1E140 EXAM ROOM 13
1E142 TRAUMA 02 (16) B 1E142 TRAMA ROOM 02
1E143 EXAM/TR (13) B 1E143 EXAM ROOM 10
1E144 ANTE 1E144
1E145 DIETARY B 1E145 DIETARY
1E146 TRAUMA 01 (17) B 1E146 TRAMA ROOM 01
1E147 UTIL CLEAN B 1E147 CLEAN UTILITY ROOM
1E151 AMBULANCE ENT B 1E151 AMBULANCE ENTRANCE
1E153 ISO(15) B 1E153 MEDICATION ROOM
1E160 TLT/SHR A 1E160 RESTROOM/SHOWER
1E161 C.LINEN B 1E161 I.T. CLOSET
1E255 RAD B 1E255 RADIOLOGY
1S100 REGISTRATION B 1S100 PATIENT REGISTRATION
1S101 BENE COORD B 1S101 BENEFITS COORDINATOR
1S102 BEREAVMENT B 1S102 BREAVEMENT
1S104 SCN ASST B 1S104 ASCN ASSISTANT
1S105 ED MED CHIEF B 1S105 ED MEDICAL CHIEF
1S106 PAT REG SUP B 1S106 PATIENT REGISTRATION SUPERVISOR
1S109 SCN B 1S109 SCN OFFICE
1S110 STAFF RR 1S110 OBSERVATION 01
1S111 OBSERV (21) B 1S111 OBSERVATION 02
1S112 OBSERV (20) 1S112 OBSERVATION 03
1S114 ALCOVE 1S114 ALCOVE
1S115 LOCKERS B 1S115 EQUIPMENT STORAGE
1S116 STAFF RR B 1S116 STAFF RESTROOM
1S117 EMT STOR G 1S117 EMT STORAGE
1S118 RISER RM 1S118 RISER ROOM
No. Date Description
3 1/24/24 RFI Response
© Copyright 2013, CSI, 110 South Union St., Suite 100, Alexandria, VA 22314
Page ___ of ___ Form Version: January 2013 CSI Form 1.5C
SUBSTITUTION
REQUEST
(During the Bidding/Negotiating Stage)
Project:
To:
Re:
Substitution Request Number:
From:
Date:
A/E Project Number:
Contract For:
Specification Title:
Section: Page:
Description:
Article/Paragraph:
Proposed Substitution:
Manufacturer: Address: Phone:
Trade Name: Model No.:
Attached data includes product description, specifications, drawings, photographs, and performance and test data adequate for evaluation of the request; applicable portions of the data are clearly identified.
Attached data also includes a description of changes to the Contract Documents that the proposed substitution will require for its proper installation.
The Undersigned certifies:
• Proposed substitution has been fully investigated and determined to be equal or superior in all respects to specified product.
• Same warranty will be furnished for proposed substitution as for specified product.
• Same maintenance service and source of replacement parts, as applicable, is available.
• Proposed substitution will have no adverse effect on other trades and will not affect or delay progress schedule.
• Proposed substitution does not affect dimensions and functional clearances.
• Payment will be made for changes to building design, including A/E design, detailing, and construction costs caused by the substitution.
Submitted by:
Signed by:
Firm:
Address:
Telephone:
A/E’s REVIEW AND ACTION
☐ Substitution approved - Make submittals in accordance with Specification Section 01 25 00 Substitution Procedures.
☐ Substitution approved as noted - Make submittals in accordance with Specification Section 01 25 00 Substitution Procedures.
☐ Substitution rejected - Use specified materials.
☐ Substitution Request received too late - Use specified materials.
Signed by: Date:
Supporting Data Attached: ☐ Drawings ☐ Product Data ☐ Samples ☐ Tests ☐ Reports ☐
Tony.M Typewritten Text
GIMC EMERGENCY
DEPT. PHASE 2
Tony.M Typewritten Text
JOHNSON SMITTHIPONG &
ROSAMOND ASSOCIATES, INC.
Tony.M Typewritten Text
SOLID PHENOLIC LOCKERS
Tony.M Typewritten Text 105100
Tony.M Typewritten Text
Tony.M Typewritten Text
2.1 A
Tony.M Typewritten Text Locker manufacturers
Tony.M Typewritten Text
SUMMIT PHENOLIC LOCKERS
Tony.M Typewritten Text
SUMMIT LOCKERS
Tony.M Typewritten Text 138 McLeod Road Columbia, SC 29203
Tony.M Typewritten Text
(803) 403-8816
Tony.M Typewritten Text Tony Menka
Tony.M Typewritten Text Tony Menka
Tony.M Typewritten Text Norcon of New Mexico
Tony.M Typewritten Text 8437 Washington Pl NE b, Albuquerque, NM 87113
Tony.M Typewritten Text 505-343-8801
Tony.M Typewritten Text x
Tony.M Typewritten Text x
Tony.M Typewritten Text Norcon of New Mexico
Tony.M Typewritten Text 1/18/24
Tony.M Typewritten Text 21-070
SUMMIT LOCKERS PHENOLIC LOCKER
803-403-8816 | WWW.SUMMITLOCKERS.COM | INFO@SUMMITLOCKERS.COM
SUMMIT LOCKERS, INC. - 138 MCLEOD ROAD, COLUMBIA, SC 29203
Mortised Joints Mortise and tenon joints lock pieces together using stainless steel screws for superior strength and durability.
Ventilation Our lockers are designed with ventilation in mind with space around the doors to provide multi-directional ventilation.
Overlay Doors
Full sized / overlay doors increase the usable size of each locker for optimal usage.
Hygienic
Non-porous surfaces which make Summit's lockers safe and easy to clean.
Completely Customizable | Durable | Low Maintenance | Luxurious Look
Water Resistant
Summit Standard Phenolic Locker
Construction Mortise and Tenon Joints Full Overlay Doors Stainless Steel Fasteners Multi - Directional Ventilation
Material Thickness Top, Bottom & Shelves – White – 3/8“ Sides & Backs – White – 5/16“ Doors & Trim – Std. Colors – 1/2"
Sizes Height - 60”, 72”, 84” Width - 12”, 15”, 18”, 20” Depth – 12”, 15”, 18”, 20”
Hinges Concealed 6-Knuckle Stainless Steel
Lock Hasp for padlock
Fire Rating Class B
Base Not Included
Top Flat-Unfinished: White
Standard Configurations
1-Tier 2-Tier
3-Tier 4-Tier
5-Tier 6-Tier Z-Tier
INNOVATIVE LOCKERS
FOR YOUR NEXT PROJECT, PLEASE CALL 803-403-8816,
YOU MAY ALSO EMAIL YOUR QUESTIONS TO INFO@SUMMITLOCKERS.COM
Material Thickness 3/8” sides and shelves 3/8” sides and ½” shelves 1/2” sides and shelves
Hinges 180° Hinge (ADA Compliant) Continuous Stainless Steel Euro Hinge Soft-Close Hinges
Fire Rating Class A
Top Sloped Flat Finished Front Facia
Base Adjustable Base w/ Toe Kick Integral Base
Don't see your option listed? Just ask.
All locker orders are tailored to fit your needs.
Sizes Custom sizes available upon request.
Lock Vendors DigiLock® Lowe & Fletcher®
CODELOCKS® OMJAR®
ZEPHYR Lock® Gantner® Master Lock®
Color Custom Color Interior Through-Color Phenolic
Other Logo Engraving Through Door Ventilation Stay Closed Door Magnets Stainless Steel Coat Rod Shoulder pad/Helmet Rack USB Outlets LED Lighting
Phenolic Locker Customizations
Your home for innovation www.summitlockers.com | (803)403-8816 | info@summitlockers.com
Since opening our doors in 2011, Summit has tripled our production capacity and shipped to over 2,000 customers in all 50 states! We are dedicated to working with owners, architects, specialty companies, contractors, and installers to ensure that all your locker projects are a success.
Summit was founded on a simple premise that customers need durable lockers and a dependable company to partner with; and we were right.
WHO WE ARE
Superior Design Premium Materials & Superior Durability
To build a better locker, Summit chose to build our lockers with phenolic panels, mortised joints, and stainless steel fasteners in lieu of butt joints, welds, or pop rivets. Our shelves feature tenons that provide strength to support heavy loads resulting in a stronger, more durable, and rigid locker. These lockers are built with full, overlay doors and hidden ventilation to improve access, appearance, storage capacity, and ventilation.
Mortised Joints
Summit Locker's mortise and tenon joints lock pieces together using stainless steel screws for superior strength and durability.
Ventilation
Our lockers are designed with ventilation in mind with space around the doors to provide multi-directional ventilation.
Overlay Doors
Our full sized / overlay doors increase the usable size of each locker for optimal usage.
Hygienic
Our lockers are composed of non-porous surfaces which make them safe and easy to clean.
Water Resistant
Water Resistant & Durable Phenolic lockers
Summit Phenolic lockers combine the appeal of wooden lockers with low maintenance and superior durability. Phenolic lockers are perfect for high traffic, as well as high moisture areas.
Athletic Lockers
Our athletic lockers provide a competitive advantage by combining strength, durability, low maintenance, and custom designs for professional, collegiate, and high school teams.
t h e l o o k o f s u c c e s s
High Density Polyethylene (HDPE) lockers have through- color panels and perform well in high moisture areas. Numerous sizes and styles make these lockers suitable for all facilities.
HDPE Lockers Durable Solid Plastic
Benches
Cubbies Summit provides cubbies in all sizes and configurations. From small mail cubbies all the way to equipment storage, we can meet your needs.
Summit provides locker room benches in Solid Phenolic, Solid Plastic (HDPE), and hardwood to meet customer's design needs including ADA compliant options. We offer a wide variety of options to mount your benches.
Specialty Products Cabinets
Pass-Through lockers
Equipment Lockers
Storage Boxes
Cubby Benches/ integral bench
Summit's Solid Phenolic Specialty products can be customized to fit any project. We offer 300+ color options, door pulls, locks, color coated tags, magnetic catches, and custom interior options.
Locks
Phenolic
**Visit summitlockers.com for more information on colors and Locks
Solid phenolic lockers have a nonporous, easy to clean surface that is water, mold, and mildew resistant.
Summit Lockers has over 300 color options available to choose from.
HDPE
HDPE lockers have an orange peel, nonporous, and easy to clean surface. Our lockers are water, mold, and mildew resistant.
Summit manufactures cabinets and lockers while working with industry leading lock suppliers to meet your security needs. Here are a few companies we work with:
GOING GREEN
INNOVATIVE LOCKER ROOM SOLUTIONS
Durable & Long Lasting
Summit Lockers are made in the U.S.A.
using environmentally friendly materials.
We use modern high-precision equipment to provide consistent and top quality products. Our design and manufacturing capabilities enables us to create a variety of custom products.
Sustainability
Summit Lockers addresses sustainability through the production of durable lockers that are manufactured with environmentally aware components.
The result is a longer lasting locker that uses less natural resources.
As an environmentally friendly company, our lockers are made from recycled materials in several ranges to qualify for GREENGUARD indoor air quality and LEED certification.
Contact us (803)403-8816 info@summitlockers.com www.summitlockers.com
138 McLeod Road
Columbia, SC 29203
756- Natural Maple 758- Blossom Cherrywood 3712- Walnut Butcherblock 8842- Weathered Ash 8844- Aged Ash
9012- Ebony 9283- Walnut Riftwood 9312- Planked Urban Oak 9484- Oxidized Beamwood 909- Black
912- Storm 927- Folkstone 928- Mouse 949- White 961- Fog
969- Navy Blue 5342- Earth 7197- Dover White 8751- Mojave 8793- Green Slate
515- Graphite Grafix 3709- Brushed Iron 3711- Slate Noir 3720- White Pearl Cascade 5880- Earthen Warp
6307- Burnt Strand 6696- Carrara Bianco 6697- Argento Romano 7732- Butterum Granite 8826- Neutral Twill
803-403-8816 | WWW.SUMMITLOCKERS.COM | INFO@SUMMITLOCKERS.COM
SUMMIT LOCKERS, INC. - 138 MCLEOD ROAD, COLUMBIA, SC 29203
FORMICA PHENOLIC
Completely Customizable | Durable | Low Maintenance | Luxurious Look
STANDARD HASP BAR LOCK
803-403-8816 | WWW.SUMMITLOCKERS.COM | INFO@SUMMITLOCKERS.COM
SUMMIT LOCKERS, INC. - 138 MCLEOD ROAD, COLUMBIA, SC 29203
The standard locking option for Summit Phenolic Lockers is a through door mounted 11 gauge stainless steel hasp bar for end-user supplied padlocks. The hasp bar is secured to the locker side panels using theft proof stainless steel fasteners and protrudes through the door for ultimate security.
On the front of the door we provide a reverse side engraved plastic ID tag and door pull. The ID tag is reverse side engraved with ½” tall numbers so that the numbers will not deteriorate or collect dirt. The tag also provides protection from the padlock hitting the door.
- ID Plate is attached with double sided adhesive tape.
*ALTERNATIVE LOCKING MECHANISMS AND ID TAGS/DOOR PULLS ARE AVAILABLE UPON REQUEST*
FOR YOUR NEXT PROJECT, PLEASE CALL 803-403-8816,
YOU MAY ALSO EMAIL YOUR QUESTIONS TO INFO@SUMMITLOCKERS.COM
Options
Material Thickness 3/8” sides and shelves 3/8” sides and ½” shelves 1/2” sides and shelves
Sizes Custom sizes available upon request.
Hinges 180° Hinge/ADA Compliant Continuous Stainless Steel Euro Hinge
Lock Vendors DigiLock® Lowe & Fletcher®
CODELOCKS® OMJAR®
ZEPHYR Lock® Gantner® Master Lock®
Fire Rating Class A
Base Adjustable Base with Toe Kick Integral Base
Top Sloped Flat Finished Front Facial
Color Custom Color Interior Through-Color Phenolic
Other Logo Engraving Through Door Ventilation Stay Closed Door Magnets Stainless Steel Coat Rod
Mortise and Tenon Joints Full Overlay Doors Stainless Steel Fasteners Stainless Steel Coat Hooks Multi - Directional Ventilation
Top, Bottom & Shelves – White – 3/8“ Sides & Backs – White – 5/16“ Doors & Trim – Std. Colors – 1/2"
Height - 60”, 72”, 84” Width - 12”, 15”, 18”, 20” Depth – 12”, 15”, 18”, 20”
Concealed 6-Knuckle Stainless Steel
Hasp for padlock
Unfinished - White
Standard Details
Construction
Material Thickness
Sizes
Hinges
Lock
Fire Rating Class B
Base Not Included
Top
Don't see your option listed? Just ask. All locker orders are tailored to fit your needs.
Amend No. Item # Date Submitted
Question Type (Technical or
Admin) Question Response
Date
Response Responded By
A00002 1 N/A Admin SEE RESPONSE TO BRAND NAME PROPOSALS 12/27/2023
Proposals shall incorporate all brand names identified in the solicitation or approved "equal" incorporated via solicitation amendment. If proposing an "equal" not approved during the solicitation process, contractors shall submit a separate price proposal, in addition to the price proposal for the brand names identified in the solicitation. The price proposal for "equal" items shall include all information requested on CSI Form 13.1A
Contracting
A0001 2 12/20/2023 Technical How many CAT 6A ports shall be installed per TELE/DATA drop? Is it two (2), three (3) or four (4)?
12/21/2023 Provide four (4) ports with six (6) port stainless steel coverplates with two (2) blanks for non-ported outlets for all Tele/Data outlets. Design Firm
A0001 3 12/20/2023 Technical
Are the stainless-steel cover plates to be four (4) port or six (6) cover plates?
On the drawings/plans page E151 General Notes Section B states: “All tele/data outlets shall be (4) port with (6) port cover plates.”
Keyed notes section 3 states: “Provide (2) port voip data outlets, typical unless noted otherwise. Installation shall be complete with (1) 1''c stubbed from data outlet to basket cable tray. Conduits shall terminate at cable tray with a nylon bushing. Provide (2) cat6 plenum rated cables from data ports to patch panel within data management rack within it 1e129. All cat6 cabling shall be terminated at each data port and at patch panel. All cat6 cables shall be tested and certified.”
On the Drawings/plans page E001 Tele/Data Legend indicates a “Wall mounted data Outlet – With 3 Data drops” for the indicated icon of a black triangle with a center fill of all white.
In the specifications document page 1474 (271510-5) section 2.3 Modular Jacks part B states:
“Provide stainless steel four port keystone compatible faceplates. Provide blank closures where required. Comply with all Owner requirements for faceplate configurations.”
12/21/2023
Refer to response 1 above.
Design Firm
A0001 4 12/20/2023 Technical
The Specifications documentation is asking for this specific warranty while also naming CommScope and Leviton to be used in separate portions of the system. In order to obtain a 25-year warranty, the entire cabling installation will need to consist of products from the same manufacturer, end-to-end, and a certified installer to sign off on the project.
For this project a Siemons certification or CommScope certification can be obtained. Shall we submit the bid for the project with the 25-year warranty or bid as specified which would not qualify for the 25 year warranty?
Specifications document page 1491 and 1492 (280513-3 and 280513-3 states:
2.3 UTP CABLE
A.Manufacturers: Subject to compliance with requirements, provide products by one of the following:
1.CommScope, Inc.
2.4UTP CABLE HARDWARE
A.Manufacturers: Subject to compliance with requirements, provide products by one of the following:
1.Leviton Commercial Networks Division.
Specifications document page 1473 (271510-4) states:
1.6WARRANTY
A.The Contractor shall warranty all material, equipment, and work performed under this contract for one (1) year from date of acceptance.
The full cost of maintenance, labor, and materials to correct any defect shall be included in this bid.
B.Provide manufacturer network infrastructure solution 25 year extended product warranty.
C.Submittal shall include documentation and certification from the manufacturer regarding authorization to provide the manufacturer’s 25 year extended product warranty.
12/21/2023
Provide a 1 year warranty.
Design Firm
A0002 5 12/20/2023 Technical
The specification is asking for a 25-pair utility feed although this does not seem to be depicted in the plans/drawing and the requested cable type does not exist. Can we please have clarification regarding this specific request.
2.2 CABLING
B.Utility feed and backbone copper cabling shall be 25 pair, CommScope CAT-6A, 550 Mhz, plenum rated cable (or rated as required for feed and entrance), or as directed by Owner.
1.The Contractor shall coordinate existing copper feeds with the Owner prior to bidding the project regarding what may be re-used and what must be replaced.
12/21/2023
The 25 pair cable (24 AWG, MEGAPIC-NF OSP Broadband Backbone CAT5, Solid Annealed Copper, Polymer Coated Corrugated Aluminum Tape Sheild) should be installed from GW-28 to New IDF at ED Expansion.
IHS
Design Firm
A0002 6 12/21/2023 Technical 271500 Horizontal Cabling: 271500 Horizontal Cabling:
Can you provide details on the existing horizontal cabling system? (e.g., cable types, specifications) 12/22/2023
.All 24 AWG Copper Cables (24 AWG, MEGAPIC-NF OSP Broadband Backbone CAT5, Solid Annealed Copper, Polymer Coated Corrugated Aluminum Tape Sheild) are terminated from D-Mark (GW28) to the perposed IDF locations.
IHS/GIMC
A0002 7 12/21/2023 Technical 271500 Horizontal Cabling: 271500 Horizontal Cabling: Is the owner open to considering a BerkTek & Leviton cabling solution with 20 year manufacturer warranty? 12/22/2023
As long as the copper cables are Sheilded with Polymer Coated Corrugate Tape. Cables need to be grounded/sheilded due to signal interferences. IHS/GIMC
A0002 8 12/21/2023 Technical 271500 Horizontal Cabling: Is the owner intending to use existing backbone cable, or is any new backbone cable or fiber required. If so, please provide specifications. 12/22/2023
Yes, New Copper (See Cable required in ITEM#4) and New Fiber (12 strand single-mode OS/2, Duplex) terminated at each end with a 1RU Rack Mount and Cira Telecom 25 pair Lightning Protected 110 Block. IHS/GIMC
A0002 9 12/21/2023 Technical 275116 Public Address System: Please provide the specifications for the existing Public Address system including the brand and models?
12/21/2023 BOGEN Paging/Intercom System
IHS/GIMC
A0002 10 12/21/2023 Technical 275116 Public Address System: Is the existing system capable of handling the additional speakers specified for this project, or will a new headend be required for the new area? 12/22/2023
The existing Bogen Paging System will handle speakers for this project but all overhead speakers will need to terminate in the IDF Room. IHS/GIMC
A0002 11 12/21/2023 Technical 275116 Public Address System: Are there any specific features or capabilities that we should consider in matching the existing system?
12/22/2023 The ceiling speakers should be drop-in ceiling speakers by Bogen.
IHS/GIMC
A0002 12 12/21/2023 Technical 275223 Nurse Call/Code Blue: Could you provide specifications for the current nurse call/Code Blue system, including the manufacturer and model? 12/21/2023
Hill-Rom/Baxter (Voalte) Nurse Call system
IHS/GIMC
A0002 13 12/21/2023 Technical 275223 Nurse Call/Code Blue:Is the existing Nurse call system capable of handling the expansion required for the new areas? 12/22/2023 Yes, Hill-Rom/Baxter (Voalte) will need to installed by a certified Hill-Rom Installer. IHS/GIMC A0002 14 12/21/2023 Technical 275223 Nurse Call/Code Blue: Is the owner open to a different nurse call system 12/22/2023 No, GIMC is only using Hill-Rom Voalte System IHS/GIMC
A0002 15 12/21/2023 Technical 281300 Access Control (Controller, Card Readers): Please provide the brand and model of access control equipment that is currently implemented? 12/21/2023
Tyco Software House (C-Cure 9000 v2.9)
IHS/GIMC
A0002 16 12/21/2023 Technical 281300 Access Control (Controller, Card Readers): Is the system capable of handling the new access control equipment required for the new areas? 12/22/2023
We (GIMC) will need to verify with current contractor on new installation and warranty.
IHS/GIMC
A0002 17 12/21/2023 Technical 282300 Video Surveillance (Interior and Exterior): Can you share details on the existing video surveillance system, including Video Management system, camera types and specifications? 12/21/2023
ExacqVision Video Management – Professional with Hanwha Techwin Camera’s (In & Outdoor, Day & Night Camera’s) IHS/GIMC
A0002 18 12/21/2023 Technical 282300 Video Surveillance (Interior and Exterior): What are the preferences for capabilities and features? 12/22/2023 Each indoor camera (4M Network IR Dome Camera) 4 mega pixel IHS/GIMC
A0002 19 12/21/2023 Technical 282300 Video Surveillance (Interior and Exterior): Will the current NVR be used to connect to the new cameras, or will a new NVR be required? If the existing NVR is to be used, please provide the existing storage capacity and number of cameras connected. 12/22/2023
The new cameras will need to be connected/configured to our current NVR System.
IHS/GIMC
A0002 20 12/21/2023 Technical 282300 Video Surveillance (Interior and Exterior): If a new NRV is required, please indicate what the desired retainage is for stored video – number of days or months, and what frame rate is expected. 12/22/2023
Use current NVR but licenses maybe required for configuration of new cameras.
IHS/GIMC
A0001 21 12/21/2023 Technical Low Voltage Cabling Demolition Responsibility: Who is responsible for the demolition of existing low voltage cabling and devices?
12/21/2023 Electrical contractor.
Design Firm
A0001 22 12/21/2023 Technical What is the existing Fire Alarm system that needs to be matched?
12/21/2023 Siemens Fire Alarm Panel – Model: FHD2007-R3 (THIS IS MAINTAINED BY GIMC-BOILER DEPT.)
IHS/GIMC
A0004 23 12/29/2023 Technical
Ground Floor Demo Plans sheet A112, and Ground Floor Plan sheet A121:
At the existing thick wall north of GL F.3, keynote 01 24 indicates infilling of existing window openings between GL 19 to 20.6 with 2 hour construction. Neither plan seems to define where those windows are removed or are to be infilled. Keynote 01 24 also appears on this wall west of GL 19 which is outside of the GL 19 to 20.6 parameters described in the keynote. Please define how the 2 hour separation is to be constructed. Is this two layers of 8” CMU? If so, can we get a detail of how this is to be constructed? The unnamed area along GL F.3, and roughly between GL 21 to 22, appears to be completely covered by the First Floor and has no access. Is this area filled with dirt? Keynote 02 19 indicates removal of existing windows and infill with CMU. Please provide detail of the CMU infill.
1/8/2024
Refer to attached detail Window In-Fill Detail in Concrete Wall.pdf - Attachment 1, Amendment 4
Design Firm
A0004 24 12/29/2023 Technical Ground Floor Plan sheet A121:
Keynote 03 41 refers to Structural Detail 14/S210 for reinforcing at infill of temporary stair egress, but there are no structural drawings provided.
1/8/2024 Refer to attached In-Fill Detail in Concrete Wall.pdf - Attachment 2, Amendment 4
Design Firm
A0004 25 12/29/2023 Technical Elevations sheet A201, and Details D1 and D2 on sheet A405:
There is no callout for the wall finish below Level 1 (0”), and extending down the stairs to entry door GE50B. Please clarify. 1/8/2024
Exposed concrete. Finish shall be “patch & rub” smooth monochromatic concrete.
Design Firm
A0007 26 1/23/2024 Technical Sign types C1, C2, D, E, F, J, K, L not seen on sign schedule or sign plan. Please confirm these signs are not needed for this phase. 1/24/2024
Yes, the sign details on A602 are needed for the complete sign package. Refer to the attached drawing A603r3 for all of the sign locations. (See Amendment 7) Design Firm
| B05 Amendment 7 |
| SF30 Continuation Page |
| B03 Site Visit Roster Jan 19 |
| A602r3 - Sign Schedule |
| Sheets |
| A602 - SIGN SCHEDULE |
| CSI Request Sheet Norcon New Mexico |
| B04 RFI Response 1-26 |
File details come from the government source that posted it. Updated .