This document contains an amendment to a federal solicitation for construction services. The solicitation is for the construction of staff quarters at the Peach Springs Indian Health Service facility in Arizona, including site work and utilities. Key details include specifications for site grading, post-tension concrete slabs, interior and exterior walls, HVAC, plumbing and electrical systems. The amendment provides responses to contractor questions to clarify contract requirements such as foundation depths, wall framing attachments, and material specifications. It also notes submittal due dates of November 28, 2023. The Indian Health Service is the contracting agency managing this project.
View the file
Other files
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:
(a) By completing items 8 and 15, and returning or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
E. IMPORTANT: Contractor is not is required to sign this document and return copies to the issuing office.
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT 1. CONTRACT ID CODE
3. EFFECTIVE DATE 4. REQUISITION/PURCHASE REQUISITION NUMBER
7. ADMINISTERED BY (If other than Item 6) CODE
STANDARD FORM 30 (REV. 11/2016)
Prescribed by GSA FAR (48 CFR) 53.243
FACILITY CODE
10A. MODIFICATION OF CONTRACT/ORDER NUMBER
10B. DATED (SEE ITEM 13)
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers is extended. is not extended.
12. ACCOUNTING AND APPROPRIATION DATA (If required) copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NUMBER AS DESCRIBED IN ITEM 14.
CHECK ONE A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER
NUMBER IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation data, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
15C. DATE SIGNED
15A. NAME AND TITLE OF SIGNER (Type or print)
16C. DATE SIGNED
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
PAGE OF PAGES
6. ISSUED BY CODE
8. NAME AND ADDRESS OF CONTRACTOR (Number, street, county, State and ZIP Code) (X)
CODE
15B. CONTRACTOR/OFFEROR
(Signature of person authorized to sign)
16B. UNITED STATES OF AMERICA
(Signature of Contracting Officer)
Previous edition unusable
2. AMENDMENT/MODIFICATION NUMBER
A0005
Andrew Hart, Supervisory Contracting Officer
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
The purpose of this amendment is to provide an updated Q&As as of November 16, 2023. See next page.
The Solicitation closing date and time remain November 28, 2023 at 1:00 PM (Pacific Time).
All other terms and conditions of this solicitation remain unchanged.
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
Indian Health Service - DES Seattle 701 Fifth Ave, Suite 1600 Seattle, WA 98104
See Item 6
9A. AMENDMENT OF SOLICITATION NUMBER
75H70124R00009
5. PROJECT NUMBER (If applicable)
20-080
1 3
11/16/2023
9B. DATED (SEE ITEM 11)
10/19/2023
Amend No. Item # Date Submitted
Question Type
(Technical or Admin)
Question Response Date Response Responded
By
EXAMPLE 0 11/23/2020 Technical Please provide drawings or plans for ??? 11/23/2020 IHS Response IHS POC
A0001 1 10/25/2023 Technical
1. Can the Government provide the Environmental Assessment and Environmental Clearance documents for the project? Specification Section 01 57 20.00 10 Environmental Protection references the contractor’s responsibility under this section and page 3. 1.7 Environmental Protection Plan and 1.8 Protection Features page 6, references working within areas that have been surveyed/cleared for our planed work area however the area is not referenced on the plans. Also, 1.9 Special Environmental Requirements page 6, Swainson’s Hawk Nesting survey requirements within 10-days of starting on-site work in addition to the February 1 – August 31 nesting season. Additionally, this section references Archaeology, Waters of the US, Wetlands, and other concerns. The clearance documents will help us better understand what the contractor will be required to address under this section and to price the work accordingly.
10/31/2023
The NEPA document was provided with RFC package. Please send to all contractors.
"1.9 Special Environmental Requirements page 6, Swainsons hawk nesting survey requirements" are not pertinent to this project. I am not sure where that is called out in the contract but needs to be removed. This is an oversight by JSRA.
IHS PM
A0001 2 10/25/2023 Technical
2. Can the Government provide the Civil Engineering CAD files?
Attachment B01 DRAWINGS Sheets C001 to C602 show the site civil work to be preformed by the contractor and the CAD file will assist us in provide accurate pricing for the work described in the drawing. 10/31/2023
The following base CAD files have been provided to the Government for distribution: Existing Grade.xml, Finished Grade.xml, MA-CS-SI-41629.06 (10-30- 2023).dwg, MC-VB-41629.06 (10-30- 2023).dwg
Design Firm
A0001 3 10/25/2023 Technical
3. How is the interior wall framing to be attached to the post-tension (PT) slab? Sheet S511, Detail 102 - Perimeter Footing A PT Slab, indicates how the exterior wall framing is to be attached to the PT slab however the interior wall anchoring is not shown or described.
10/31/2023
Non-loadbearing interior partition walls shall be anchored directly to the post-tension slab through use of power-driven fasteners . Power driven fasteners shall be a length that does not extend into the tendon zone of the slab when attached to the wall sill plate. Refer to Detail S512/108 Similar
Design Firm
A0002 4 11/1/223 Technical
My question is regarding what type of substrate are you using under the Standing Seam Metal Roof Panels. This is no call out in the specifications and the only call out on the attached drawings is “WSP” (see attached highlighted drawings). Is this 5/8” plywood or OSB being used. We need to know this for wind loads.
11/2/2023
Refer to Sheet S001 "ROUGH
CARPENTRY AND WOOD
STRUCTURAL PANELS; item 2.
Substrate is Contractors option, provided that substrate conforms to referenced performance standards of stated section.
Design Firm
A0002 5 11/2/2023 Technical
CPVC plastic pipe is UL Listed and FM approved for 13D and 13R wet pipe systems for light and ordinary group 1. Will we be able to use CVPC pipe for this project? 11/2/2023
Provide sprinkler piping listed in drawings and specification. No Substitutions of the sprinkler piping material accepted at this time.
Design Firm
A0004 6 11/8/2023 Technical
Is the Government concerned about trapping Raydon Gas in the buildings?
The plans and specification call for the contractor to insulate with spray foam insulation. This in addition to other specified construction methods will make the buildings very tight regarding ventilation.
11/9/2023
Project site located in Mohave County, Arizona which is designated as a Zone 2 under the EPA Map of Radon Zones.
Zone 2 is classified as Moderate potential;
average indoor radon levels may bebetween 2 and 4 pCi/L. Proposed design is a post-tension slab on grade with a polyethylene vapor barrier preventing soil gases from entering the dwelling unit.
In addition this foundation system will consist of 19 inches of 3% soil cement under building slab to support the slab and edge footings.
Design Firm
A0004 7 11/8/2023 Technical
Is Option 0009 – Duplex 2 Bedroom Multi-family house (LOT 10) and associated sitework intended to read “Duplex 1 Bedroom Multi-family house”? Page 3 of the RFP request a pricing option for the Duplex 2 Bedroom Multi-family house and the drawing only show Duplex 1 Bedroom Multi-family house units.
11/8/2023
Correct the Price schedule should say 1 BR (Not 2 BR).
IHS PM
A0004 8 11/8/2023 Technical
Is B.2. PRICE SCHEDULE 0004 “Install utility services as shown on the attached plans and associated work, intended for all utilities under 8”? Page 3 of the RFP Option 0007 8” Sewer main and appurtenances and associated sitework requests LS Price and Option 0008 8” Sewer main and appurtenances and associated sitework request LS Price.
11/8/2023
Refer to the Plans Cover sheet G001 for explanation of the utility Bid Options. Line item 0004 is for all utility service lines from the main to the units. IHS PM
A0004 9 11/8/2023 Technical
Is Section H – Special Contract Requirements, H1.1 TRIBE REQUIERMENTS – WHITE MOUNTAIN APACHE TRIBE and all other White Mountain Apache Tribe references intended to read Hualapai Trib? In the RFP Page 15, the contact provided under H.1. D is for the Hualapai Tribe – TERO Office and all other references are White Mountain Apache Tribe.
11/9/2023
The RFP Section H.1. was updated. See the Amendment A0004.
IHS CS
A0004 10 11/8/2023 Technical
Is the contractor to install storm drain piping at LOT 14? At the site visit Mr.
Kemmet indicated that the contractor will be installing storm drain piping and this is not indicated on the plans. 11/8/2023
I mis spoke. Refer to sheet C602 where there is a drainage channel proposed and not a storm sewer pipe. IHS PM
A0004 11 11/8/2023 Technical
Is the Geotechnical Date indicated in Note #8 “Soil Cement Stabilization Extents. Refer to Geotechnical Report and Structural Plans for Details” on sheet C102 missing in Specification Section 003132 Geotechnical Data?
We are not able to locate this information in the specification under Section 003132 however some information is shown on Sheet S121.
11/9/2023
Refer to PDF page 60 of specification manual, document titled "Geotechnical Exploration Report – Addendum 1 Earthwork and Driveway Recommendations". Document if found as last page to DOCUMENT 003132 - GEOTECHNICAL DATA of the specifications. Refer to sheet C102 and S511 in addtion to stated sections.
Design Firm
A0004 12 11/8/2023 Technical
Is the depth of the foundation at 9” total shown on Sheet S511 detail 103 sufficient to address frost heavy in accordance with the Geotechnical Data?
Specification section 003132 5.3.1 Shallow Spread Footing indicates that an anticipated frost depth for the project area is 12 to 24-inches below existing site grade, this appears to conflict with Sheet S511 detail 103 showing a total depth for the Post Tension Slab footing at 9”.
11/9/2023
Project has been designed to use a post tension slab on grade foundation system and not a spread footing foundation system. The post tension slab is further supported by a 19 inch deep 3% soil cement mixture. Section 5.3.1 "Shallow Spread Footings" of the GeoTechnical document is not applicable. A 9 inch bearing depth for the post tension slab turn downs is sufficient. Refer to Geotechnical report #210211 Rev. 1 Section 5.1.4 Post-Tension slab.
Design Firm
A0004 13 11/9/2023 Technical
Can the Government provide a Furniture Plan for the Single-Family Building? Sheet A722 Duplex Furniture Plan, Sheet A723.1 Triplex Furniture Plan (West) & Sheet A723.2 Triplex Furniture Plan (East) are sheets we have that show the furniture layout for these units. We are missing the Furniture Plan Sheet for the Single-Family Home.
11/9/2023
Furniture plans and Furniture lists for the single family homes are intentionally not provided nor available. Furniture for the Single family homes and Duplex and Triplex are not included in this scope of work. Refer to RFP 75H70124R00009 Peach Springs Staff Quarters.pdf, section C-4.D. For further information related to Fixtures, furniture and equipment.
Design Firm
A0005 14 11/13/2023 Technical
Specification section 09519-3 calls out six resilient LVT products and the plan set finish schedule page A601, calls out.
one LV -1 Tarkett product Aloft/ Coopers Oak Roan which products will be required.
1/14/2023
Specification states "Basis-of-Design Product: Subject to compliance with requirements, provide Tarkett Home;
Aloft Glue Down or comparable product by one of the following:...ect". Refer to section 016000 - 1.3B for Basis of Design requirements.
Design Firm
A0005 15 11/13/2023 Technical
Specification Section 22 3300 calls out Electric Domestic water heaters.
Plan sheets P002 Plumbing Equipment Schedule calls out Solar water heater systems-WH 1 and WH 2 are both types required for all floor plans? 11/14/2023
Both type of water heaters are required as shown on the drawings.
Design Firm
| B05 Addendum #1 2023 09 26.pdf |
| Subject: Pre-Bid Meeting Minutes & Plan Set Revision, Santa Clara Pueblo – East Housing Lift Station, IHS Project No. AL-18-A86 |
| 2022 10 24 B77 Addendum Drawings.pdf |
| 4 |
| scattered housing b77 Revision #1 1- Drywater (1) |
| scattered housing b77 Revision #1 2 - Hererra (1) |
| scattered housing b77 Revision #1 3 - Sanchez (1) |
| scattered housing b77 Revision #1 5-Pecos & Lewis (1) |
| scattered housing b77 Revision #1 22X34 PLAN (1-40) (1) |
| ADP90E0.tmp |
| SECTION B. PRICE SCHEDULE |
| ADPD131.tmp |
| SECTION B. PRICE SCHEDULE |
| ADP129C.tmp |
| PPI Log |
| ADP619A.tmp |
| PPI Log |
| ADP5719.tmp |
| PPI Log |
| ADP38C1.tmp |
| PPI Log |
File details come from the government source that posted it. Updated .