This is a set of architectural and engineering design drawings for a fire alarm system replacement project at Building 4213, Marine Corps Air Station (MCAS) Cherry Point, North Carolina.

The project, identified as Work Order 7504546, involves replacing the existing fire alarm and mass notification system with a new combined system compliant with NFPA 72 (2025 Edition), UFC 3-600-01 with Change 6 (2021 Edition), and UFC 4-021-01 with Change 1 (2010 Edition). Key work deliverables include: (1) providing and installing a fire alarm control panel, VESDA early warning smoke detection panel, fire alarm terminal box, and notification power panels; (2) installing 120V electrical conduit and wiring to panels; (3) providing and installing MNS radio antenna and transceiver; (4) installing conduit, wire, and cable hangers; (5) installing fire alarm notification appliances, detection devices, and interface devices; (6) installing VESDA tubing and sample ports; (7) testing and commissioning the integrated system including interfaces with sprinkler and HVAC equipment; (8) demolishing the existing fire alarm system; and (9) patching and repairing damaged surfaces. The facility is a two-story, fully-sprinklered building with mixed business and storage occupancies totaling approximately 23,264 square feet. System design requires Class A wiring for all circuits, dedicated signaling line circuits, minimum 18 AWG for SLC and 16 AWG for NAC circuits, and installation in 3/4-inch diameter EMT conduit. The fire alarm system must provide audibility and intelligibility throughout designated areas of rescue assistance, with specific sound level and clarity metrics defined. All outages exceeding one hour require coordination with the contracting officer, fire watch personnel, and government oversight; continuous outages are prohibited, and overnight outages are restricted unless work is actively ongoing with restoration within one hour of completion.

View the file

Other files

File Type Posted
Amendment 0001.pdf PDF
Master PPI Form.xlsx XLSX spreadsheet
7504546 RFP.pdf PDF
7504546 SpecsAsOne.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PROJECT LOCATION

LAY DOWN AREA

MAIN GATE PASS AND

ID OFFICE

ROOSEVELT BLVD.

PROJECT LOCATION

BUILDING 4213

SLOCUM GATE

BUILDING

BUILDING

BEAUFORT RD.

E STREET

ROOSEVELT BLVD

PROJECT LOCATION

2ND AVE.

E STREET ROOSEVELT BLVD

BULLDOG RD

BUILDING 4213

FI

LE

N

AM

E:

OU

R

RE

F:

PL

OT

D

AT

E:

7/2

1/2

6 4 :59

:43 P

M

1.0

G-

1.D W

G

C O

VE

R

S H

EE

T

G-001

SHEET

NUMBER SHEET TITLE NAVFAC

DWG NO.

G-001 COVER SHEET 12939619

GI001 BUILDING CODE SUMMARY 12939620

GI100 COMPOSITE LIFE SAFETY 12939621

GI101 LIFE SAFETY - FIRST FLOOR 12939622

GI102 LIFE SAFETY - SECOND FLOOR 12939623

FA001 SYMBOLS & ABBREVIATIONS 12939624

FD101 FIRE ALARM - FIRST FLOOR - DEMOLITION 12939625

FD102 FIRE ALARM - FIRST FLOOR - DEMOLITION - AREA B 12939626

FD103 FIRE ALARM - SECOND FLOOR - DEMOLITION - AREA A 12939627

FD104 FIRE ALARM - SECOND FLOOR - DEMOLITION - AREA B 12939628

FA101 FIRE ALARM - FIRST FLOOR - NEW WORK 12939629

FA102 FIRE ALARM - FIRST FLOOR - NEW WORK - AREA B 12939630

FA103 FIRE ALARM - SECOND FLOOR - NEW WORK - AREA A 12939631

FA104 FIRE ALARM - SECOND FLOOR - NEW WORK - AREA B 12939632

FA501 FIRE ALARM MATRIX 12939633

FA502 FIRE ALARM RISER 12939634

M-001 SYMBOLS AND ABBREVIATIONS 12939635

M-101 FLOOR PLAN 12939636

E-001 SYMBOLS & ABBREVIATIONS 12939637

ED101 FIRST FLOOR - DEMOLITION 12939638

E-101 FIRST FLOOR PLAN 12939639

E-102 SECOND FLOOR PLAN 12939640

REPLACE FIRE ALARM SYSTEM

CHERRY POINT, NORTH CAROLINA

WORK ORDER NO.

BUILDING 4213

VICINITY MAPLOCATION MAP DRAWING INDEX

MARINE CORPS AIR STATION

7504546

N N 12939619

A

B

C

D

1 2 3 4 5

1 2 3

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW

SY

M

DE

SC

RI

PT

IO

N

DA

TE

AP

PR

CHK

SATISFACTORY TO

ACTIVITY

DATE

FOR COMMANDER NAVFAC

OF

EPROJECT NO.:

AS NOTED

<<PM/DM>>

BRANCH MANAGER

CHIEF ENG/ARCH

<<XX>>

4325 Lake Boone Trail|Suite 301|Raleigh, NC 27607

(984) 204-4500 | www.summerconsultants.com

SUMMER

CONSULTANTS

I N C O R P O R A T E D

4 5

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y

MC

AS

C

HE

RR

Y

PO

IN

T, N

C

CH

ER

RY

P

OI

NT

, N

C

FA

C

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

A

C Q

U

IS

IT

IO

N S

D

IV

IS

IO

N M

C

AS

C H

ER

R

Y

PO

IN

T

- C H

ER

R

Y

PO

IN

T, N C

BU

IL

DI

NG

RE

PL

AC

E

FI

RE

A

LA

RM

S

YS

TE

M

N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

C O

M M

AN

D

MA

RI

NE

C

OR

PS

A

IR

S

TA

TI

ON

, C

HE

RR

Y

PO

IN

T, N

C

7504546

CHRISTOPHER R LIN

PATRICK FAULKNER

PHASING PLAN AND SEQUENCING REQUIREMENTS

1. PROVIDE AND INSTALL FIRE ALARM PANEL, VESDA PANEL, FIRE ALARM TERMAINAL BOX, NOTIFICATION POWER PANELS.

2. PROVIDE AND INSTALL 120 V ELECTRICAL CONDUIT AND WIRING TO PANELS.

3. PROVIDE AND INSTALL MNS RADIO ANTENNA AND TRANSCIEVER.

4. PROVIDE AND INSTALL CONDUIT AND WIRE, AND INSTALL HANGARS.

5. PROVIDE AND INSTALL FIRE ALARM NOTIFICATION APPLIANCES, DETECTION DEVICES, AND INTERFACE DEVICES.

6. PROVIDE AND INSTALL VESDA TUBING AND SAMPLE PORTS.

7. TEST AND COMMISSION FIRE ALARM SYSTEM INCLUDING SPRINKLER AND HVAC EQUIPMENT INTERFACES.

8. DEMOLISH EXISTING FIRE ALARM SYSTEM.

9. PATCH AND REPAIR WALLS, CEILINGS, ETC DAMAGED BY CONTRACTOR OR WHERE EXISTING EQUIPMENT WAS REMOVED.

RJP RJP AP

AutoCAD SHX Text

2ND AVENUE

AutoCAD SHX Text

C STREET

AutoCAD SHX Text

E STREET

AutoCAD SHX Text

1ST AVENUE

AutoCAD SHX Text

ROOSEVELT BLVD

AutoCAD SHX Text

CURTIS ROAD

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

NOT TO SCALE

Marciniak Snapshot

FI

LE

N

RE

F:

PL

OT

D

AT

E:

7/2

1/2

6 4 :59

:51 P

M

1.0

GI

1 L

IF

E

SA

FE

TY

N

AR

RA

TI

VE

.D

W G

GI001

BU

ILD

IN

G

CO

DE

S

UM

MA

RY

RJP RJP AP

A

B

C

D

1 2 3 4 5

1 2 3

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW

SY

M

DE

SC

RI

PT

IO

N

DA

TE

AP

PR

CHK

SATISFACTORY TO

ACTIVITY

DATE

FOR COMMANDER NAVFAC

OF

EPROJECT NO.:

AS NOTED

<<PM/DM>>

BRANCH MANAGER

CHIEF ENG/ARCH

<<XX>>

4325 Lake Boone Trail|Suite 301|Raleigh, NC 27607

(984) 204-4500 | www.summerconsultants.com

SUMMER

CONSULTANTS

I N C O R P O R A T E D

4 5

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y

MC

AS

C

HE

RR

Y

PO

IN

T, N

C

CH

ER

RY

P

OI

NT

, N

C

FA

C

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

A

C Q

U

IS

IT

IO

N S

D

IV

IS

IO

N M

C

AS

C H

ER

R

Y

PO

IN

T

- C H

ER

R

Y

PO

IN

T, N C

BU

IL

DI

NG

RE

PL

AC

E

FI

RE

A

LA

RM

S

YS

TE

M

N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

C O

M M

AN

D

MA

RI

NE

C

OR

PS

A

IR

S

TA

TI

ON

, C

HE

RR

Y

PO

IN

T, N

C

7504546

CHRISTOPHER R LIN

PATRICK FAULKNER

APPLICABLE CODES

1. UNIFIED FACILITIES CRITERIA (UFC)

· 2023 UFC 1-200-01 DOD BUILDING CODE WITH CHANGE 2

· 2021 UFC 3-600-01 FIRE PROTECTION ENGINEERING FOR FACILITIES WITH CHANGE 6

· 2022 UFC 4-010-01 DOD MINIMUM ANTITERRORISM STANDARDS FOR BUILDINGS WITH CHANGE 2

· 2010 UFC 4-021-01 DESIGN AND O&M: MASS NOTIFICATION SYSTEMS WITH CHANGE 1

· 2021 UFC 3-520-01 INTERIOR ELECTRICAL SYSTEMS WITH CHANGE 2

2. INTERNATIONAL CODE COUNCIL (ICC)

· 2024 INTERNATIONAL BUILDING CODE (IBC)

3. NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)

· 2024 INTERNATIONAL EXISTING BUILDING CODE (IEBC)

· 2021 FC 1-300-09N NAVY AND MARINE CORPS DESIGN PROCEDURES WITH CHANGE 6

· 2024 NFPA 1 FIRE CODE

· 2022 NFPA 10 STANDARD FOR PORTABLE FIRE EXTINGUISHERS

· 2023 NFPA 70 NATIONAL ELECTRICAL CODE

· 2025 NFPA 72 NATIONAL FIRE ALARM AND SIGNALING CODE

· 2024 NFPA 101 LIFE SAFETY CODE

· 2022 NFPA 241 STANDARD FOR SAFEGUARDING CONSTRUCTION, ALTERATION, AND DEMOLITION

OPERATIONS

MAJOR PROJECT

REQUIRED - PER UFC 3-600-01 SECTION 2-1.20, THE WORK FALLS UNDER MAJOR PROJECT REQUIREMENTS.

PROVIDED - THIS PROJECT INCLUDES THE MODIFICATION AND ADDITION TO THE FIRE ALARM AND DETECTION

SYSTEM THIS PROJECT MEETS MAJOR PROJECT REQUIREMENTS.

EXISTING FACILITY

REQUIRED - PER UFC 3-600-01 SECTION 34-1.2.1, THE BUILDING WILL CONFORM TO THE REQUIREMENTS FOR

NFPA 101 CHAPTER 43 BUILDING REHABILITATION.

PROVIDED - THIS PROJECT WILL BE CATEGORIZED AS MODIFICATION DUE TO THE

REPLACEMENT OF THE FIRE ALARM AND DETECTION SYSTEM. ALL NEW WORK AND MATERIALS

WILL MEET NEW CONSTRUCTION CRITERIA INCLUDING BUT NOT LIMITED TO IBC AND NFPA 101

CRITERIA. THE BUILDING WILL REMAIN OCCUPIED OUTSIDE AREA OF WORK. LIFE SAFETY

SYSTEMS WILL REMAIN ACTIVE THROUGHOUT CONSTRUCTION.

CONSTRUCTION TYPE

REQUIRED - PER IBC SECTION 601, ALL BUILDINGS MUST BE ASSIGNED A TYPE OF CONSTRUCTION.

PROVIDED - THE FACILITY MOST CLOSELY RESEMBLES CONSTRUCTION TYPE IIB IN ACCORDANCE WITH IBC

CHAPTER 6.

OCCUPANCY USE

REQUIRED - NFPA 101 SECTION 6.1.14 ALLOWS MULTIPLE OCCUPANCIES TO BE TREATED AS MIXED USE

NON-SEPARATED WHERE INCIDENTAL TO ANOTHER OCCUPANCY.

PROVIDED - THE FACILITY WILL BE TREATED AS A MIXED USE NON-SEPARATED OCCUPANCY TYPE.

OCCUPANCY CLASSIFICATIONS

IN ACCORDANCE WITH IBC CHAPTER 3 AND NFPA 101 CHAPTER 6.

1. BUSINESS / B

2. STORAGE / S-2

3. FACTORY INDUSTRIAL / F-2

BUILDING AREA

THE ALLOWABLE AREA PER FLOOR IS BASED ON IBC SECTION 506.

OCCUPANCY ALLOWABLE AREA, SM

BUSINESS (B) 69,000 SF

PER IBC SECTION 506.2.2, THE TOTAL ALLOWABLE AREA OF EACH STORY OF A MIXED-OCCUPANCY BUILDING

SHALL BE DETERMINED IN ACCORDANCE WITH EQUATION 5-3:

Aa = [At + (SM x If)]

WHERE:

Aa = ALLOWABLE AREA (SQUARE FEET) At = TABULAR ALLOWABLE AREA FACTOR IN ACCORDANCE WITH TABLE 506.2

SM = TABULAR ALLOWABLE AREA FACTOR IN ACCORDANCE WITH TABLE 506.2 (SPRINKLERED

BUILDING)

If = AREA FACTOR INCREASE DUE TO FRONTAGE AS CALCULATED IN ACCORDANCE WITH TABLE 506.3.3

TABLE 506.2 ALLOWABLE AREAS

STORAGE (S-2) 78,000 SF

ALLOWABLE AREA, Aa

BUILDING AREA (CONT.)

AFTER APPLYING EQUATION 5-3, THE FOLLOWING ALLOWABLE AREA PER FLOOR WAS CALCULATED:

REQUIRED - ALLOWABLE AREA PER FLOOR - 69,000 SQUARE FEET

PROVIDED - FIRST FLOOR AREA - 15,456 SQUARE FEET

SECOND FLOOR AREA - 7,808 SQUARE FEET

COMPONENT REQUIRED FIRE RESISTANCE

PRIMARY STRUCTURAL FRAME 0 HOUR

BEARING WALLS 0 HOUR

NONBEARING WALLS AND BY OTHER CRITERIA

FLOOR CONSTRUCTION AND SECONDARY MEMBERS 0 HOUR

ROOF CONSTRUCTION AND SECONDARY MEMBERS 0 HOUR

FIRE RESISTANCE RATING

REQUIRED OCCUPANCY SEPARATION - 0 HOUR

PROVIDED OCCUPANCY SEPARATION - 0 OR 1 HOUR.

PER IBC TABLE 601, REQUIRED AND PROVIDED FIRE RESISTANCE TABLE BY CONSTRUCTION TYPE.

PROVIDED FIRE RESISTANCE

BY OTHER CRITERIAEXTERIOR

INTERIOR 0 HOUR 0 HOURPARTITIONS

EXTERIOR

INTERIOR 0 HOUR

0 HOUR

0 HOUR

0 HOUR

0 HOUR

0 HOUR

PER NFPA 101 CHAPTER 8, VERTICAL OPENING FIRE PROTECTION ASSEMBLIES, RATINGS AND MARKINGS.

ENCLOSURES FOR SHAFTS 1 HOUR

1 HOURINTERIOR EXIT STAIRWAYS

1 HOUR

1 HOUR

OCCUPANT LOAD

OCCUPANCY

CLASSIFICATION OCCUPANCY USE GROUP

OCCUPANT LOAD

FACTOR COMMENTS AREA

OCCUPANT

LOAD

FIRST FLOOR

BUSINESS LESS CONCENTRATED 150 SF/PERSON

STORAGE IN NON-STORAGE 500 SF/PERSON

TOTAL

INDUSTRIAL

GROSS

SECOND FLOOR

BUSINESS LESS CONCENTRATED 150 SF/PERSON

STORAGE IN NON-STORAGE 500 SF/PERSON

TOTAL

BUSINESS CONFERENCE 15 SF/PERSON

GROSS

PER UFC 3-600-01 CHAPTER 10 AND NFPA 101 CHAPTER 7.

4,107 SF 41

5,313 SF 36

4,164 SF 8

15,456 SF 179

141 SF 9

6,583 SF 44

282 SF 1

7,808 SF 94

GENERAL 100 SF/PERSON

OCCUPANCY

MAX ALLOWABLE TRAVEL

DISTANCE

MAX ALLOWABLE COMMON

PATH OF TRAVEL

MAX ALLOWABLE DEAD

END

MEANS OF EGRESS

STORAGE 400 FEET 100 FEET 100 FEET

BUSINESS 300 FEET 100 FEET 50 FEET

BUILDING CODE AND LIFE SAFETY NARRATIVE

REQUIRED ARRANGEMENT OF EGRESS

- SPRINKLER PROTECTED

REQUIRED - TRAVEL DISTANCES MUST BE LESS THAN MOST STRICT REQUIREMENT (INDUSTRIAL).

PROVIDED - TRAVEL DISTANCES ARE LESS THAN MOST STRICT REQUIREMENT (INDUSTRIAL).

SEE LIFE SAFETY PLANS FOR LOCATIONS OF ACTUAL ARRANGEMENT OF EGRESS.

REQUIRED: EXIT REMOTENESS SHALL AT MINIMUM BE 1/3RD OF THE LENGTH OF BUILDING DIAGONAL.

PROVIDED: EXITS ARE GREATER THAN 1/3RD OF THE BUILDINGS DIAGONAL APART.

REQUIRED # OF EXITS PER FLOOR - 2

PROVIDED # OF EXITS PER FLOOR - 2

THE PROJECT ENTAILS THE REPLACEMENT OF THE BUILDING 4213 FIRE ALARM SYSTEM. B4213 IS A TWO STORY FULLY-SPRINKLERED BUILDING CONSISTING OF BUSINESS AND STORAGE OCCUPANCIES. B4213 INCLUDES A

ONE-STORY STRUCTURE WHICH IS CONNECTED TO THE BUILDING WITH A COVERED WALKWAY.

REQUIRED # OF ACCESSIBLE EXITS PER FLOOR - 2

PROVIDED # OF ACCESSIBLE EXITS PER FLOOR - 2

INDUSTRIAL 250 FEET 50 FEET100 FEET

BUILDING STORIES AND HEIGHT

PER IBC TABLE 504.3

ALLOWABLE STORIES/HEIGHT - 4 STORIES/75'

PROVIDE STORIES/HEIGHT - 2 STORIES/35'

MAXIMUM ALLOWABLE QUANTITIES

IBC TABLE 307.1 AND 414.2

ALLOWABLE CONTROL AREAS PER FLOOR - 1

CONTROL AREA QUANTITY

ALLOWABLE FIRST FLOOR - 100%

ALLOWABLE SECOND FLOOR - 75%

PROVIDED: ALL QUANTITIES ARE ASSUMED TO BE BELOW HIGH HAZARD OCCUPANCY HAZARD

DESIGNATION.

INTERIOR FINISHES

NFPA 101 CHAPTER 10, 38, 40, 42

UFC 3-600-01 CHAPTER 8

BUSINESS

INTERIOR - MINIMUM CLASS B IN EXITS

FLOOR - CLASS II IN EXITS

STORAGE

INTERIOR - MINIMUM CLASS C IN EXITS

FLOOR -CLASS II IN EXITS

INDUSTRIAL

INTERIOR - MINIMUM CLASS C IN EXITS

FLOOR - NO REQUIREMENTS

NET

FIRE PROTECTION AND MASS NOTIFICATION SYSTEMS

REQUIRED - UFC REQUIRES MULTI-STORY FACILITIES TO BE FULLY PROTECTED WITH AN AUTOMATIC

WET-PIPE SPRINKLER SYSTEM IN COMPLIANCE WITH NFPA 13 AND UFC 3-600-01.

PROVIDED - THE BUILDING IS FULLY PROTECTED WITH AN AUTOMATIC WET-PIPE SPRINKLER SYSTEM IN

COMPLIANCE WITH NFPA 13 AND UFC 3-600-01.

REQUIRED - UFC REQUIRES A FIRE ALARM SYSTEM IN COMPLIANCE WITH NFPA 72 AND UFC 3-600-01 AND A

MASS NOTIFICATION SYSTEM IN COMPLIANCE WITH UFC 4-021-01.

PROVIDED - THE BUILDING WILL BE PROVIDED WITH A COMBINED FIRE ALARM AND MASS NOTIFICATION

SYSTEM IN COMPLIANCE WITH NFPA 72, UFC 3-600-01, AND UFC 4-021-01.

FIRE EXTINGUISHERS

REQUIRED - PER UFC 3-600-01 SECTION 9-17.1 AND NFPA 101 SECTION 39.3.5, PORTABLE FIRE EXTINGUISHERS

SHALL BE PROVIDED IN EVERY BUSINESS OCCUPANCY.

PROVIDED - FIRE EXTINGUISHERS ARE PROVIDED AS REQUIRED BY THE UFC AND NFPA 101.

EMERGENCY LIGHTING

REQUIRED - PER NFPA 101 SECTION 39.2.9, EMERGENCY LIGHTING SHALL BE PROVIDED IN ACCORDANCE WITH

NFPA 101 SECTION 7.9

PROVIDED - FIRE EXTINGUISHERS ARE PROVIDED AS REQUIRED BY THE UFC AND NFPA 101.

FACTORY

INDUSTRIAL (F-2) 69,000 SF

CLASSROOM TRAINING 20 SF/PERSON 1,872 SF 94

20 SF/PERSON 802 SF 40NET

NET

CLASSROOM TRAINING

EGRESS CAPACITY

THE FACILITY EGRESS CAPACITY FACTORS ARE:

- 0.2 INCHES/PERSON FOR LEVEL COMPONENTS

- 0.3 INCHES PER PERSON FOR STAIR AND RAMP COMPONENTS

REQUIRED - EGRESS CAPACITY MUST BE ABLE TO SUPPORT OCCUPANT LOAD

PROVIDED - EGRESS CAPACITY IS ADEQUATE TO SUPPORT OCCUPANT LOAD. SEE LIFE SAFETY PLANS FOR

CAPACITY PER EXIT

69,000 SF

78,000 SF

69,000 SF

12939620

N

RE

F:

PL

OT

D

AT

E:

7/2

1/2

6 5 :00

:13 P

M

1.0

GI

0 C

OM

PO

SI

TE

LI

FE

S

AF

ET

Y.

DW

G

A

B

C

D

1 2 3 4 5

1 2 3

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW

SY

M

DE

SC

RI

PT

IO

N

DA

TE

AP

PR

CHK

SATISFACTORY TO

ACTIVITY

DATE

FOR COMMANDER NAVFAC

OF

EPROJECT NO.:

AS NOTED

<<PM/DM>>

BRANCH MANAGER

CHIEF ENG/ARCH

<<XX>>

4325 Lake Boone Trail|Suite 301|Raleigh, NC 27607

(984) 204-4500 | www.summerconsultants.com

SUMMER

CONSULTANTS

I N C O R P O R A T E D

4 5

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y

MC

AS

C

HE

RR

Y

PO

IN

T, N

C

CH

ER

RY

P

OI

NT

, N

C

FA

C

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

A

C Q

U

IS

IT

IO

N S

D

IV

IS

IO

N M

C

AS

C H

ER

R

Y

PO

IN

T

- C H

ER

R

Y

PO

IN

T, N C

BU

IL

DI

NG

RE

PL

AC

E

FI

RE

A

LA

RM

S

YS

TE

M

N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

C O

M M

AN

D

MA

RI

NE

C

OR

PS

A

IR

S

TA

TI

ON

, C

HE

RR

Y

PO

IN

T, N

C

7504546

CHRISTOPHER R LIN

PATRICK FAULKNER

GI100

CO

MP

OS

IT

E

LIF

E

SA

FE

TY

RJP RJP AP

N0 32' 64' 1/32"=1'-0"

LIFE SAFETY - COMPOSITE1

FIRE HYDRANT

ROOSEVELT BLVD. FIRE

TRUCK ACCESS

FIRE HYDRANT

12939621

L M N

C D E FA B G H J K O P

87" HIGH SHELVING

72" HIGH SHELVING (TYP.) 63" HIGH SHELVING

TRAVEL DISTANCE = 126'

BUILDING DIAGONAL = 184'

REQUIRED EXIT REMOTENESS = 61 '

S

500 SF/P

S

500 SF/P

S

500 SF/P

S

500 SF/P

S

500 SF/P

STAIR

LOBBY

SIMULATOR

MECH

OFFICE

OFFICE

STORAGE

STORAGE

CORRIDOR

OFFICE

STORAGE

LOBBY

BATHROOM

STORAGE

SHOP

SHOP

STAIR

BAY 1 184

BAY 2

OFFICE

OFFICE

OFFICE

OFFICE

SHOP

MECH.

SHOP

VAULT

CLASSROOM

COMMON PATH = 100'

A

20 SF/P

ROOF

ROOF

ROOF

I

100 SF/P

I

100 SF/P

I

100 SF/P

I

100 SF/P

S

500 SF/P

B

150 SF/P

B

150 SF/P

A

20 SF/P

B

150 SF/P

B

150 SF/P

FE

FE

FE

FE

FE

FE

DEAD END = 20'

A B C D E

F

FI

LE

N

RE

F:

PL

OT

D

AT

E:

7/2

1/2

6 5 :01

:44 P

M

1.0

GI

1 L

IF

E

SA

FE

TY

FI

RS

T

FL

OO

R.

DW

G

A

B

C

D

1 2 3 4 5

1 2 3

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW

SY

M

DE

SC

RI

PT

IO

N

DA

TE

AP

PR

CHK

SATISFACTORY TO

ACTIVITY

DATE

FOR COMMANDER NAVFAC

OF

EPROJECT NO.:

AS NOTED

<<PM/DM>>

BRANCH MANAGER

CHIEF ENG/ARCH

<<XX>>

4325 Lake Boone Trail|Suite 301|Raleigh, NC 27607

(984) 204-4500 | www.summerconsultants.com

SUMMER

CONSULTANTS

I N C O R P O R A T E D

4 5

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y

MC

AS

C

HE

RR

Y

PO

IN

T, N

C

CH

ER

RY

P

OI

NT

, N

C

FA

C

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

A

C Q

U

IS

IT

IO

N S

D

IV

IS

IO

N M

C

AS

C H

ER

R

Y

PO

IN

T

- C H

ER

R

Y

PO

IN

T, N C

BU

IL

DI

NG

RE

PL

AC

E

FI

RE

A

LA

RM

S

YS

TE

M

N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

C O

M M

AN

D

MA

RI

NE

C

OR

PS

A

IR

S

TA

TI

ON

, C

HE

RR

Y

PO

IN

T, N

C

7504546

CHRISTOPHER R LIN

PATRICK FAULKNER

KEY PLAN

NOT TO SCALE

KEY PLAN

N

GI101

LIF

E

SA

FE

TY

FI

RS

T

FL

OO

R

RJP RJP AP

LIFE SAFETY LEGEND

DEAD END (DE)

COMMON PATH OF

TRAVEL (CPT)

MAXIMUM TRAVEL

DISTANCE (TD)

2 HOUR FIRE BARRIER

200 0.3

1 HOUR FIRE BARRIER

200 0.2

PORTABLE FIRE

EXTINGUISHERFE

EXIT SIGN

A

15 SF/P

OCCUPANCY USE

OCCUPANT LOAD

FACTOR (OLF)

SQUARE FEET/

PERSON

NUMBER OF OCCUPANTS

USING EXIT STAIR

EGRESS WIDTH

CAPACITY FACTOR

MAXIMUM NUMBER OF

OCCUPANTS EGRESS

WIDTH CAN SUPPORT

NUMBER OF OCCUPANTS

USING EXIT DOOR

EGRESS WIDTH

CAPACITY FACTOR

MAXIMUM NUMBER OF

OCCUPANTS EGRESS

WIDTH CAN SUPPORT

N0 24'8' 16' 3/32"=1'-0"

LIFE SAFETY PLAN - FIRST FLOOR1

BUSINESS USE - LESS CONCENTRATED

STORAGE USE - IN NON-STORAGE

INDUSTRIAL USE - GENERAL

OCCUPANCY USE GROUP LEGEND

84 0.2

36 0.2

36 0.2

CLASSROOM - TRAINING

22 0.2

36 0.2

17 0.2

17 0.2

1 0.2

12939622

ROOF

HIGH BAY

OPEN TO BELOW

ROOF

ROOF

L M N

C D E FA B

G H J K

O

HIGH BAY

OPEN TO BELOW

TRAVEL DISTANCE = 95'

BUILDING DIAGONAL = 131'

REQUIRED EXIT REMOTENESS = 44 '

STAIR

CLASSROOM

OFFICE

OFFICE

CORRIDOR

MAIL

OFFICE

OFFICE

VAULT

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

MECH.

LOCKERS

BATHROOM

JANITORIAL

STAIR

OFFICE

CONFERENCE

OFFICE

OFFICE

CORRIDOR

OFFICE

BATHROOM

SHOWERS

CORRIDOR

OFFICE

OFFICE

OFFICE

A

15 SF/P

OFFICE

S

500 SF/P

S

500 SF/P

EXIT REMOTENESS = 95'

47 0.3

FE

FEOPEN TO BELOW

FI

LE

N

RE

F:

PL

OT

D

AT

E:

7/2

1/2

6 5 :02

:01 P

M

1.0

GI

2 L

IF

E

SA

FE

TY

SE

CO

ND

F

LO

OR

.D

W G

A

B

C

D

1 2 3 4 5

1 2 3

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW

SY

M

DE

SC

RI

PT

IO

N

DA

TE

AP

PR

CHK

SATISFACTORY TO

ACTIVITY

DATE

FOR COMMANDER NAVFAC

OF

EPROJECT NO.:

AS NOTED

<<PM/DM>>

BRANCH MANAGER

CHIEF ENG/ARCH

<<XX>>

4325 Lake Boone Trail|Suite 301|Raleigh, NC 27607

(984) 204-4500 | www.summerconsultants.com

SUMMER

CONSULTANTS

I N C O R P O R A T E D

4 5

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y

MC

AS

C

HE

RR

Y

PO

IN

T, N

C

CH

ER

RY

P

OI

NT

, N

C

FA

C

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

A

C Q

U

IS

IT

IO

N S

D

IV

IS

IO

N M

C

AS

C H

ER

R

Y

PO

IN

T

- C H

ER

R

Y

PO

IN

T, N C

BU

IL

DI

NG

RE

PL

AC

E

FI

RE

A

LA

RM

S

YS

TE

M

N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

C O

M M

AN

D

MA

RI

NE

C

OR

PS

A

IR

S

TA

TI

ON

, C

HE

RR

Y

PO

IN

T, N

C

7504546

CHRISTOPHER R LIN

PATRICK FAULKNER

KEY PLAN

NOT TO SCALE

KEY PLAN

N

GI102

LIF

E

SA

FE

TY

SE

CO

ND

F

LO

OR

RJP RJP AP

N0 24'8' 16' 3/32"=1'-0"

LIFE SAFETY PLAN - SECOND FLOOR1

LIFE SAFETY LEGEND

DEAD END (DE)

COMMON PATH OF

TRAVEL (CPT)

MAXIMUM TRAVEL

DISTANCE (TD)

2 HOUR FIRE BARRIER

200 0.3

1 HOUR FIRE BARRIER

200 0.2

PORTABLE FIRE

EXTINGUISHERFE

EXIT SIGN

A

15 SF/P

OCCUPANCY USE

OCCUPANT LOAD

FACTOR (OLF)

SQUARE FEET/

PERSON

NUMBER OF OCCUPANTS

USING EXIT STAIR

EGRESS WIDTH

CAPACITY FACTOR

MAXIMUM NUMBER OF

OCCUPANTS EGRESS

WIDTH CAN SUPPORT

NUMBER OF OCCUPANTS

USING EXIT DOOR

EGRESS WIDTH

CAPACITY FACTOR

MAXIMUM NUMBER OF

OCCUPANTS EGRESS

WIDTH CAN SUPPORT

BUSINESS USE - LESS CONCENTRATED

STORAGE USE - IN NON-STORAGE

OCCUPANCY USE GROUP LEGEND

BUSINESS USE - CONFERENCE

47 0.2

EDUCATIONAL - CLASSROOM

12939623

N

RE

F:

PL

OT

D

AT

E:

7/2

1/2

6 5 :02

:15 P

M

1.0

FA

1.D W

G

SY

M

BO

LS

A

BB

R

EV

IA

TI

O

N S

FA001

SYMBOLS

ACOUSTICALLY DISTINGUISHABLE SPACE BOUNDARY

AREA OF WORK / FIRE ALARM ZONE

MODIFICATION OF THE FIRE ALARM SYSTEM IN

THIS AREA IS NOT IN CONTRACT (N.I.C.)

FA101

N

8'0 1/8"=1'-0"

UNIQUE PLAN OR

DETAIL NUMBER

ON THIS DRAWING NORTH ARROW

NAME OF PLAN OR DETAIL

ALL DRAWINGS WHERE

THIS DETAIL IS

REFERENCED FROM

GRAPHIC SCALE OF

THIS PLAN OR DETAIL

SECTION IDENTIFICATION

INDICATES DIRECTION

OF CUTTING PLANE

NUMBER INDICATES SECTION

SHEET NUMBER WHERE

SECTION IS DRAWN

2-PART REFERENCE DETAIL IDENTIFICATION:

SHEET NUMBER WHERE

DETAIL/SECTION IS DRAWN

NUMBER INDICATES

DETAIL/SECTION

FLOOR PLAN

FA101,FA1022

FLOOR PLAN AND DETAIL TITLES:

FA101

N

(E)

REVISION CLOUD WITH REVISION

NUMBER DESIGNATION

BREAKLINE

MATCHLINE DESIGNATIONM A T C H L I N E A-A

EXISTING

POINT OF CONNECTION TO EXISTING

POINT OF TERMINATION OF REMOVAL

NOTE NUMBER#

ARROW INDICATES TRUE NORTH

AND/OR PROJECT NORTH.

ROOM NUMBER

COLUMN LINE NUMBER

NORTH ARROW

GENERAL SYMBOLSABBREVIATIONS

F

WF

TS

PS

DH

AIM

AOM

TXT

FACP

FMCP

FAAP

FATC

BATT

NAP

AMP

LOC

LCD

RAD

MNT

SPD

ASP

MANUAL PULL STATION

WATERFLOW SWITCH

TAMPER SWITCH

PRESSURE SWITCH

FIRE DEPT. TELEPHONE

DOOR HOLD DEVICE

ADDRESSABLE INPUT (MONITOR) MODULE

ADDRESSABLE OUTPUT (CONTROL) MODULE

TEXTUAL SIGNAGE

SURGE PROTECTIVE DEVICE

FIRE ALARM CONTROL PANEL

FIRE ALARM / MASS NOTIFICATION CONTROL PANEL

FIRE ALARM ANNUNCIATOR PANEL

FIRE ALARM TERMINAL CABINET

BATTERY CABINET

NOTIFICATION APPLIANCE PANEL

AMPLIFIER RACK

LOCAL OPERATING CONSOLE

LIQUID CRYSTAL DISPLAY / ANNUNCIATOR

ASPIRATING SMOKE PANEL

RADIO TRANSMITTER

MASS NOTIFICATION TRANSCEIVER

TYPE

SMOKE DETECTOR - CEILING MOUNTED

DUCT SMOKE DETECTOR

SYMBOLS - CONT.

A AMPERES.

AC ABOVE CEILING

ADS ACOUSTICALLY DISTINGUISHABLE SPACE

AFF ABOVE FINISHED FLOOR

AHJ AUTHORITY HAVING JURISDICTION

AMP AMPLIFIER

AS ASPIRATING SMOKE

AWG AMERICAN WIRE GAUGE

C CEILING MOUNT

CA CLEAN AGENT

CL CEILING LEVEL

CIS COMMON INTELLIGIBILITY SCALE

CONT. CONTINUED

D DRAIN

DN DOWN

EEA ELECTRONIC EQUIPMENT AREA

ELEV. ELEVATOR

EMR ELEVATOR MACHINE ROOM

EMT ELECTRICAL METALLIC TUBING

ER ELEVATOR RECALL

ETR EXISTING TO REMAIN

(E) EXISTING

F FIRE LINE

FA FIRE ALARM

FAAP FIRE ALARM ANNUNCIATOR PANEL

FACP FIRE ALARM CONTROL PANEL

FMCP FIRE ALARM / MASS NOTIFICATION CONTROL PANEL

FATC FIRE ALARM TERMINAL CABINET

LOC LOCAL OPERATING CONSOLE

MNS MASS NOTIFICATION SYSTEM

NAC NOTIFICATION APPLIANCE CIRCUIT

N.I.C. NOT IN CONTRACT

P PHOTOELECTRIC

PA PRE-ACTION

(R) RELOCATE

SLC SIGNALING LINE CIRCUIT

SP SPRINKLER PIPING

SPD SURGE PROTECTIVE DEVICE

STI SPEECH TRANSMISSION INDEX

TYP. TYPICAL

U UNDER FLOOR

VP VEWSD OR VESDA SAMPLE TUBING/PIPING

VEWSD VERY EARLY WARNING SMOKE DETECTION

WP WEATHERPROOF

ZCA SPRINKLER ZONE CONTROL ASSEMBLY

S

H

CD

CD

S

CD

CD

SPEAKER - WALL MOUNTED

HORN - WALL MOUNTED

SPEAKER / STROBE - WALL MOUNTED

CD = CANDELA RATING

HORN / STROBE - WALL MOUNTED

CD = CANDELA RATING

SPEAKER - CEILING MOUNTED

SPEAKER / STROBE - CEILING MOUNTED

CD = CANDELA RATING

HORN / STROBE - CEILING MOUNTED

CD = CANDELA RATING

SECURE SPACE BOUNDARY/ACOUSTICALLY

DISTINGUISHABLE SPACE BOUNDARY

DD - DUCT SMOKE DETECTOR ACTUATOR

ST - ELEVATOR SHUNT TRIP

PR - PRIMARY ELEVATOR RECALL

AR - ALTERNATE ELEVATOR RECALL

FH - FIREMAN'S HAT

SM - ELEVATOR SHUNT TRIP POWER MONITOR

WF - WATER FLOW SWITCH

TS - TAMPER SWITCH

PARP PRE-ACTION SPRINKLER RELEASING PANEL

PS - PRESSURE SWITCH

PA - PRE-ACTION PANEL INTERFACE

DS DISCONNECT SWITCH

FCC FIRE COMMAND CENTER

FIRE ALARM REQUIREMENTS

1. MODIFY THE EXISTING FIRE ALARM AND DETECTION AND MASS NOTIFICATION SYSTEM AS INDICATED IN THE

DRAWINGS AND SPECIFICATIONS. PROVIDE A UFC 3-600-01 W/CHANGE 6 2021 EDITION, UFC 4-021-01 W/CHANGE 1

2010 EDITION AND NFPA 72 2025 EDITION COMPLIANT SYSTEM.

2. PROVIDE CLASS A WIRING FOR RISER, SLC, NAC, AND AMP CIRCUIT. PROVIDE DEDICATED SLC FOR THE FIRST FLOOR. PROVIDE MINIMUM 18 AWG FOR SLC, MINIMUM 16 FOR NAC, AND FOLLOW MANUFACTURER GUIDELINES FOR

AMPLIFIER CIRCUIT SIZE.

3. PROVIDE FIRE ALARM AND MASS NOTIFICATION CONDUCTORS IN MINIMUM 3/4-INCH DIAMETER EMT CONDUIT.

CONDUIT MUST NOT EXCEED THE NATIONAL ELECTRICAL CODE MAXIMUM FILL CAPACITY. IN FINISHED AREAS, EXPOSED CONDUIT, JUNCTION/BACK BOXES, COVERS, AND COUPLINGS MUST BE FACTORY PAINTED RED OR ARE PERMITTED TO BE PAINTED TO MATCH THE ROOM FINISH WITH THE INSIDE COVER OF JUNCTION/BACK BOXES IDENTIFIED AS "FIRE ALARM". IN UNFINISHED AREAS AND ABOVE CEILINGS, FOLLOW THE MARKING REQUIREMENTS

OF ASME 13.1.

4. PLACE EQUIPMENT AT CENTER OF ACOUSTICAL CEILINGS TILES. LOCATE EQUIPMENT ON CENTER OF SHORT TILE

AND IN 2'X4' CEILING TILE AT 1' FROM EDGE ON LONG SIDE.

5. DISCONNECT AND REMOVE THE EXISTING FIRE ALARM CONTROL PANEL AND ASSOCIATED POWER, CONDUIT, MOUNTS, ETC ON THE FIRST FLOOR.

6. DRAWINGS ARE DIAGRAMMATIC IN NATURE AND ARE NOT INTENDED TO BE USED FOR COMPLETE SYSTEM DESIGN.

COORDINATE SYSTEM COMPONENTS WITH ALL OTHER DISCIPLINES AND TRADES.

7. PROVIDE A FIRE ALARM SYSTEM DESIGNER WITH A MINIMUM NICET LEVEL III CERTIFICATION IN FIRE ALARM SYSTEM TECHNOLOGY OR A LICENSED PROFESSIONAL FIRE PROTECTION ENGINEER RESPONSIBLE FOR THE FIRE ALARM

SYSTEM DESIGN.

8. CHANGES TO THE DESIGN AND EQUIPMENT INSTALLATION IS THE RESPONSIBILITY OF CONTRACTOR. PROVIDE

DESIGN SERVICES OF A LICENSED PROFESSIONAL FIRE PROTECTION ENGINEER.

9. EXPOSED WIRING WILL NOT BE PERMITTED IN ANY PORTION OF THE BUILDING. FLEXIBLE METALLIC CONDUIT NOT EXCEEDING 6 FEET IS PERMITTED FOR TERMINATIONS AT DEVICES. ROUTE EMT CONDUIT TIGHT TO STRUCTURE.

FLEXIBLE CONDUIT MUST BE SUPPORTED AT THE CEILING LEVEL BY LISTED AND COMPATIBLE EQUIPMENT.

10. T-TAPS ARE NOT PERMITTED. CONDUIT TERMINATIONS MUST BE ON SCREW TERMINALS OF SYSTEM COMPONENT.

WIRE NUTS ARE PROHIBITED.

11. PROVIDE A LABEL FOR EACH WIRE/CIRCUIT (WITHIN ALL PANELS, CABINETS AND JUNCTION BOXES) INDICATING IT'S PURPOSE AND LOCATION. LABELS MUST BE A MINIMUM FONT SIZE OF 1/4" AND ARIAL NARROW. EXAMPLE OF A

FIRST FLOOR SIGNALING LINE CIRCUIT ONE OF TWO IS SLC-CIR1-FL1.

12. PROVIDE 25% ADDITIONAL CIRCUIT CAPACITY FOR STROBES AND SPEAKERS.

13. PANELS MUST BE FACTORY PAINTED RED.

14. SEAL FIRE BARRIER/PARTITIONS AND FIRE RATED FLOOR PENETRATIONS WITH A UL LISTED OR FM APPROVED FIRESTOPPING ASSEMBLY. FIRESTOPPING SYSTEM AT MINIMUM MATCH THE RATING OF THE PENETRATED

WALL/FLOOR.

15. ALL REQUIRED OUTAGES OF THE FIRE ALARM SYSTEM SHALL BE COORDINATED THROUGH THE CONTRACTING OFFICER NOT LESS THAN 15 WORKING DAYS IN ADVANCE. THE GOVERNMENT WILL PROVIDE THE REQUESTED OUTAGE AND ASSOCIATED RESTORATION OF THE FIRE ALARM SYSTEM. THE GOVERNMENT WILL IDENTIFY TO THE CONTRACTOR WHAT CIRCUITS/DEVICES HAVE BEEN TAKEN OUT OF SERVICE ONCE THE OUTAGE HAS BEEN MADE.

THIS WORK SHALL BE PERFORMED BY THE CONTRACTOR. OUTAGES DO NOT INCLUDE CONNECTION OF FIRE ALARM DEVICES, AND/OR WIRING TO EXISTING SYSTEMS, OR PROGRAMMING CHANGES NECESSARY TO ACCOMMODATE

NEW WORK.

16. AN EXCLUSIVE GOVERNMENT CONTRACTOR/VENDOR RESPONSIBLE FOR MAINTAINING GOVERNMENT FIRE PROTECTION SYSTEMS SHALL BE OBTAINED FOR TIE IN OF WORK AND/OR REPROGRAMMING OF OPERATING, EXISTING FIRE ALARM AND SPRINKLER SYSTEMS, AT CONTRACTORS COST.

17. A FIRE WATCH, AT CONTRACTOR'S COST, WILL BE CONDUCTED CONTINUOUSLY THROUGHOUT THE DURATION OF THE OUTAGE IN ALL AREAS AFFECTED BY THE OUTAGE. FINDINGS/COMMENTS WILL BE DOCUMENTED HOURLY ON FIRE WATCH FORMS. DOCUMENTATION OF FINDINGS WILL BE MADE AVAILABLE TO THE AUTHORITIES UPON THEIR REQUEST. IN THE EVENT OF ANY FIRE/SMOKE EMERGENCIES DISCOVERED DURING THE FIRE WATCH, EMERGENCY

NOTIFICATION SHALL BE PROVIDED TO THE PREDETERMINED POINTS OF CONTACT.

18. A CONTINUOUS OUTAGE WILL NOT BE PERMITTED TO TAKE PLACE FOR THE ENTIRE DURATION OF THE PROJECT.

OVERNIGHT OUTAGES WILL NOT BE PERMITTED UNLESS WORK IS BEING DONE DURING THAT TIME PERIOD AND THE FIRE ALARM SYSTEM IS PUT BACK INTO SERVICE WITHIN AN HOUR FROM COMPLETION OF WORK. OUTAGES SHALL

BE LIMITED TO 8 HOURS.

19. THE FIRE ALARM SYSTEM IS NOT PERMITTED TO HAVE AN OUTAGE FOR MORE THAN AN HOUR BEFORE STARTING WORK. THE FIRE ALARM SYSTEM SHALL BE RESTORED WITHIN AN HOUR OF COMPLETION OF WORK. THE

CONTRACTOR CANNOT LEAVE THE CONSTRUCTION SITE UNPROTECTED.

20. THE FIRE ALARM/MASS NOTIFICATION SYSTEM SHALL PRODUCE A SOUND LEVEL AT LEAST 15 dB ABOVE THE AVERAGE AMBIENT SOUND LEVEL, OR 5 dB ABOVE THE MAXIMUM SOUND LEVEL HAVING A DURATION OF AT LEAST 60 SECONDS, WHICHEVER IS GREATER, MEASURED 5 FT ABOVE THE FLOOR IN THE ADS REQUIRING AUDIBILITY.

21. THE INTELLIGIBILITY OF THE FIRE ALARM/MASS NOTIFICATION SYSTEM SHALL PROVIDE A CIS VALUE GREATER THAN

0.70 IN EACH ADS REQUIRING INTELLIGIBILITY.

22. UNLESS OTHERWISE NOTED, CEILING IS LESS THAN 10 FEET.

J JUNCTION BOX

ELECTRICAL METALLIC TUBING (EMT) CONDUIT

FLEXIBLE METALLIC CONDUIT (FMC)

A

B

C

D

1 2 3 4 5

1 2 3

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW

SY

M

DE

SC

RI

PT

IO

N

DA

TE

AP

PR

CHK

SATISFACTORY TO

ACTIVITY

DATE

FOR COMMANDER NAVFAC

OF

EPROJECT NO.:

AS NOTED

<<PM/DM>>

BRANCH MANAGER

CHIEF ENG/ARCH

<<XX>>

4325 Lake Boone Trail|Suite 301|Raleigh, NC 27607

(984) 204-4500 | www.summerconsultants.com

SUMMER

CONSULTANTS

I N C O R P O R A T E D

4 5

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y

MC

AS

C

HE

RR

Y

PO

IN

T, N

C

CH

ER

RY

P

OI

NT

, N

C

FA

C

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

A

C Q

U

IS

IT

IO

N S

D

IV

IS

IO

N M

C

AS

C H

ER

R

Y

PO

IN

T

- C H

ER

R

Y

PO

IN

T, N C

BU

IL

DI

NG

RE

PL

AC

E

FI

RE

A

LA

RM

S

YS

TE

M

N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

C O

M M

AN

D

MA

RI

NE

C

OR

PS

A

IR

S

TA

TI

ON

, C

HE

RR

Y

PO

IN

T, N

C

7504546

CHRISTOPHER R LIN

PATRICK FAULKNER

CEILING HEIGHT ABOVE FIXED

FLOOR

CEILING SYMBOLS

2 X 4 ACOUSTIC CEILING TILE

2 X 2 ACOUSTIC CEILING TILE

EXPOSED CEILING

CEMENT

GYPBOARD

RJP RJP AP

CARBON MONOXIDE DETECTOR

UPDC UNIVERSAL DUAL PATH COMMUNICATOR

12939624

AutoCAD SHX Text

8'-8" AFF

S

LOBBY

SIMULATOR

MECH

OFFICE

OFFICE

CLASSROOM

FIRE ALARM ZONE 1

C D E FA B

AOM

AOM

FIRE ALARM ZONE 1

MATCHLINE - CONTUNED ON FD102

H

F

SIMULATOR

MECH

F

H

FI

LE

N

RE

F:

PL

OT

D

AT

E:

7/2

1/2

6 5 :03

:47 P

M

1.0

FD

1.D W

G

GENERAL NOTES

G1. VERIFY LOCATION AND DIMENSIONS OF EXISTING

EQUIPMENT AND COORDINATE ALL WORK PRIOR TO THE

START OF CONSTRUCTION.

NOTES

1. DISCONNECT AND REMOVE ALL FIRE ALARM COMPONENTS.

2. HORN STROBE IS LOCATED ON SIMULATOR STRUCTURE

FI

R

E

AL

AR

M

FI

R

ST

F

LO

O R

D

EM

O

LI

TI

O N

AR

EA

A

FD101

N8'0 16' 1/8"=1'-0"

FIRE ALARM - FIRST FLOOR - DEMOLITION - AREA A1

A

B

C

D

1 2 3 4 5

1 2 3

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW

SY

M

DE

SC

RI

PT

IO

N

DA

TE

AP

PR

CHK

SATISFACTORY TO

ACTIVITY

DATE

FOR COMMANDER NAVFAC

OF

EPROJECT NO.:

AS NOTED

<<PM/DM>>

BRANCH MANAGER

CHIEF ENG/ARCH

<<XX>>

4325 Lake Boone Trail|Suite 301|Raleigh, NC 27607

(984) 204-4500 | www.summerconsultants.com

SUMMER

CONSULTANTS

I N C O R P O R A T E D

4 5

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y

MC

AS

C

HE

RR

Y

PO

IN

T, N

C

CH

ER

RY

P

OI

NT

, N

C

FA

C

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

A

C Q

U

IS

IT

IO

N S

D

IV

IS

IO

N M

C

AS

C H

ER

R

Y

PO

IN

T

- C H

ER

R

Y

PO

IN

T, N C

BU

IL

DI

NG

RE

PL

AC

E

FI

RE

A

LA

RM

S

YS

TE

M

N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

C O

M M

AN

D

MA

RI

NE

C

OR

PS

A

IR

S

TA

TI

ON

, C

HE

RR

Y

PO

IN

T, N

C

7504546

CHRISTOPHER R LIN

PATRICK FAULKNER

KEY PLAN

NOT TO SCALE

KEY PLAN

N

RJP RJP AP

12939625

STAIR

FFICE

STORAGE

STORAGE

CORRIDOR

OFFICE

STORAGE

LOBBY

BATHROOM

STORAGE

SHOP

SHOP

STAIR

BAY 1

BAY 2

OFFICE

OFFICE

OFFICE

OFFICE

SHOP

MECH.

SHOP

VAULT

L M N

G H J K O P

FACP

F

F

F

F

FIRE ALARM ZONE 1

G H J K L M N

F

AOM

MA

TC

HL

IN

E

- C

ON

TU

NE

D

ON

F

D1

FATC

DACT NAP

H H

F

F

VAULT

CORRIDOR

FI

LE

N

RE

F:

PL

OT

D

AT

E:

7/2

1/2

6 5 :05

:18 P

M

1.0

FD

2 F

IR

E

AL

AR

M

- F

IR

ST

F

LO

OR

DE

MO

LIT

IO

N

- A

RE

A B.

DW

G

A

B

C

D

1 2 3 4 5

1 2 3

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW

SY

M

DE

SC

RI

PT

IO

N

DA

TE

AP

PR

CHK

SATISFACTORY TO

ACTIVITY

DATE

FOR COMMANDER NAVFAC

OF

EPROJECT NO.:

AS NOTED

<<PM/DM>>

BRANCH MANAGER

CHIEF ENG/ARCH

<<XX>>

4325 Lake Boone Trail|Suite 301|Raleigh, NC 27607

(984) 204-4500 | www.summerconsultants.com

SUMMER

CONSULTANTS

I N C O R P O R A T E D

4 5

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y

MC

AS

C

HE

RR

Y

PO

IN

T, N

C

CH

ER

RY

P

OI

NT

, N

C

FA

C

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

A

C Q

U

IS

IT

IO

N S

D

IV

IS

IO

N M

C

AS

C H

ER

R

Y

PO

IN

T

- C H

ER

R

Y

PO

IN

T, N C

BU

IL

DI

NG

RE

PL

AC

E

FI

RE

A

LA

RM

S

YS

TE

M

N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

C O

M M

AN

D

MA

RI

NE

C

OR

PS

A

IR

S

TA

TI

ON

, C

HE

RR

Y

PO

IN

T, N

C

7504546

CHRISTOPHER R LIN

PATRICK FAULKNER

KEY PLAN

NOT TO SCALE

KEY PLAN

N

FD102

FI

RE

A

LA

RM

FI

RS

T

FL

OO

R

- D

EM

OL

IT

IO

N

- A

RE

A B

RJP RJP AP

N8'0 16' 1/8"=1'-0"

FIRE ALARM - FIRST FLOOR - DEMOLITION - AREA B1

GENERAL NOTES

G1. VERIFY LOCATION AND DIMENSIONS OF EXISTING

EQUIPMENT AND COORDINATE ALL WORK PRIOR TO THE

START OF CONSTRUCTION.

NOTES

1. DISCONNECT AND REMOVE ALL FIRE ALARM COMPONENTS.

12939626

STAI

OFFICE

OFFICE

ROOF

ROOF

C D E FA B

MATCHLINE - CONTUNED ON FD104

FIRE ALARM ZONE 1

FI

LE

N

RE

F:

PL

OT

D

AT

E:

7/2

1/2

6 5 :05

:36 P

M

1.0

FD

3 F

IR

E

AL

AR

M

- S

EC

ON

D

FL

OO

R

- D

EM

OL

IT

IO

N

- A

RE

A

A.

DW

G

A

B

C

D

1 2 3 4 5

1 2 3

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW

SY

M

DE

SC

RI

PT

IO

N

DA

TE

AP

PR

CHK

SATISFACTORY TO

ACTIVITY

DATE

FOR COMMANDER NAVFAC

OF

EPROJECT NO.:

AS NOTED

<<PM/DM>>

BRANCH MANAGER

CHIEF ENG/ARCH

<<XX>>

4325 Lake Boone Trail|Suite 301|Raleigh, NC 27607

(984) 204-4500 | www.summerconsultants.com

SUMMER

CONSULTANTS

I N C O R P O R A T E D

4 5

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y

MC

AS

C

HE

RR

Y

PO

IN

T, N

C

CH

ER

RY

P

OI

NT

, N

C

FA

C

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

A

C Q

U

IS

IT

IO

N S

D

IV

IS

IO

N M

C

AS

C H

ER

R

Y

PO

IN

T

- C H

ER

R

Y

PO

IN

T, N C

BU

IL

DI

NG

RE

PL

AC

E

FI

RE

A

LA

RM

S

YS

TE

M

N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

C O

M M

AN

D

MA

RI

NE

C

OR

PS

A

IR

S

TA

TI

ON

, C

HE

RR

Y

PO

IN

T, N

C

7504546

CHRISTOPHER R LIN

PATRICK FAULKNER

KEY PLAN

NOT TO SCALE

KEY PLAN

N

FD103

FI

RE

A

LA

RM

SE

CO

ND

F

LO

OR

DE

MO

LIT

IO

N

- A

RE

A A

RJP RJP AP

N8'0 16' 1/8"=1'-0"

FIRE ALARM - SECOND FLOOR - DEMOLITION - AREA A1

GENERAL NOTES

G1. VERIFY LOCATION AND DIMENSIONS OF EXISTING

EQUIPMENT AND COORDINATE ALL WORK PRIOR TO THE

START OF CONSTRUCTION.

NOTES

1. DISCONNECT AND REMOVE ALL FIRE ALARM

COMPONENTS.

2. PROVIDE SCAFFOLDING FOR WORK ON 30' CEILING AND

AROUND SIMULATOR STRUCTURE.

12939627

CLASSROOM

OFFICE

OFFICE

CORRIDOR

MAIL

OFFICE

OFFICE

VAULT

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

MECH.

CORRIDOR

LOCKERS

BATHROOM

JANITORIAL

STAIR

OFFICE

OFFICE

CONFERENCE

OFFICE

OFFICE

CORRIDOR

ROOF

HIGH BAY

OPEN TO BELOW

ROOF

OFFICE

BATHROOM

L M N

G H J K

SHOWERS

CORRIDOR

OFFICE

OFFICE

OFFICE

O

HIGH BAY

OPEN TO BELOW

FIRE ALARM ZONE 2

AOM

MA

TC

HL

IN

E

- C

ON

TI

NU

ED

O N

FD

F H F

H

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

CORRIDOR

CORRIDOR

CORRIDOR

CORRIDOR

MAIL

BATHROOM

OFFICE

CONFERENCE

FI

LE

N

RE

F:

PL

OT

D

AT

E:

7/2

1/2

6 5 :05

:52 P

M

1.0

FD

4 F

IR

E

AL

AR

M

- S

EC

ON

D

FL

OO

R

- D

EM

OL

IT

IO

N

- A

RE

A

B.

DW

G

GENERAL NOTES

G1. VERIFY LOCATION AND DIMENSIONS OF EXISTING

EQUIPMENT AND COORDINATE ALL WORK PRIOR TO THE

START OF CONSTRUCTION.

NOTES

1. DISCONNECT AND REMOVE ALL FIRE ALARM COMPONENTS.

A

B

C

D

1 2 3 4 5

1 2 3

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW

SY

M

DE

SC

RI

PT

IO

N

DA

TE

AP

PR

CHK

SATISFACTORY TO

ACTIVITY

DATE

FOR COMMANDER NAVFAC

OF

EPROJECT NO.:

AS NOTED

<<PM/DM>>

BRANCH MANAGER

CHIEF ENG/ARCH

<<XX>>

4325 Lake Boone Trail|Suite 301|Raleigh, NC 27607

(984) 204-4500 | www.summerconsultants.com

SUMMER

CONSULTANTS

I N C O R P O R A T E D

4 5

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y

MC

AS

C

HE

RR

Y

PO

IN

T, N

C

CH

ER

RY

P

OI

NT

, N

C

FA

C

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

A

C Q

U

IS

IT

IO

N S

D

IV

IS

IO

N M

C

AS

C H

ER

R

Y

PO

IN

T

- C H

ER

R

Y

PO

IN

T, N C

BU

IL

DI

NG

RE

PL

AC

E

FI

RE

A

LA

RM

S

YS

TE

M

N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

C O

M M

AN

D

MA

RI

NE

C

OR

PS

A

IR

S

TA

TI

ON

, C

HE

RR

Y

PO

IN

T, N

C

7504546

CHRISTOPHER R LIN

PATRICK FAULKNER

FI

R

E

AL

AR

M

SE

C O

N D

F

LO

O R

D

EM

O

LI

TI

O N

AR

EA

B

FD104

N8'0 16' 1/8"=1'-0"

FIRE ALARM - SECOND FLOOR - DEMOLITION - AREA B1

RJP RJP AP

12939628

C D E FA B

F

F

F

FIRE ALARM ZONE 1

FIRE ALARM ZONE 1

AOM

AOM

S

WP

S

WP

MATCHLINE - CONTUNED ON FA102

ADS 2

ADS 1

ASP

AIMAIMAIM AOM

LOBBY

MECH

OFFICE

OFFICE

CLASSROOM

S

NAP

ADS 1

15 S

SIMULATOR

FI

LE

N

RE

F:

PL

OT

D

AT

E:

7/2

1/2

6 5 :07

:25 P

M

1.0

FA

1.D W

G

GENERAL NOTES

G1. VERIFY LOCATION AND DIMENSIONS OF EXISTING

EQUIPMENT AND COORDINATE ALL WORK PRIOR TO THE

START OF CONSTRUCTION.

G2. ALL WORK SHALL BE NEW AND PROVIDED UNDER THIS

CONTRACT UNLESS SPECIFICALLY MARKED "EXISTING",

"EXIST", OR "(E)".

NOTES

1. PROVIDE FIRE ALARM AND MASS NOTIFICATION SYSTEM IN

ACCORDANCE WITH NFPA 72 AND UFC 4-021-01.

2. PROVIDE SPEAKER/STROBE ATTACHED TO THE

SIMULATOR STRUCTURE.

3. PROVIDE SMOKE DETECTOR MOUNTED IN THE UNIT

ENCLOSURE FOR AHU. PROVIDE REMOTE ALARM

INDICATORS FOR ALL SMOKE DETECTORS WITH

INDICATORS NOT VISIBLE TO RESPONDING PERSONNEL.

4. PROVIDE ADDRESSABLE OUTPUT MODULE FOR

SIMULATOR SHUTDOWN.

5. PROVIDE VERY EARLY WARNING SMOKE DETECTION

PANEL. MONITOR THE ALARM, TROUBLE, SUPERVISORY,

FILTER MISSING/DIRTY, POWER LOSS, AIR-FLOW TO HIGH

OR LOW, POWER SUPPLY, AND FAULT BY THE FMCP.

PROVIDE TUBING ABOVE 31 FOOT TALL CEILING AND

SAMPLE POINTS PER MANUFACTURER AND NFPA 75

SPACING ALONG WITH INSIDE VESTIBULE. AIR CHANGES

PER HOUR ARE 2.5.

6. PROVIDE INTELLIGIBILITY THROUGHOUT ADS 1.

7. PROVIDE AUDIBILITY THROUGHOUT ADS 2.

8. ROUTE CONDUIT ABOVE THE BREEZEWAY CEILING.

A

B

C

D

1 2 3 4 5

1 2 3

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW

SY

M

DE

SC

RI

PT

IO

N

DA

TE

AP

PR

CHK

SATISFACTORY TO

ACTIVITY

DATE

FOR COMMANDER NAVFAC

OF

EPROJECT NO.:

AS NOTED

<<PM/DM>>

BRANCH MANAGER

CHIEF ENG/ARCH

<<XX>>

4325 Lake Boone Trail|Suite 301|Raleigh, NC 27607

(984) 204-4500 | www.summerconsultants.com

SUMMER

CONSULTANTS

I N C O R P O R A T E D

4 5

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y

MC

AS

C

HE

RR

Y

PO

IN

T, N

C

CH

ER

RY

P

OI

NT

, N

C

FA

C

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

A

C Q

U

IS

IT

IO

N S

D

IV

IS

IO

N M

C

AS

C H

ER

R

Y

PO

IN

T

- C H

ER

R

Y

PO

IN

T, N C

BU

IL

DI

NG

RE

PL

AC

E

FI

RE

A

LA

RM

S

YS

TE

M

N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

C O

M M

AN

D

MA

RI

NE

C

OR

PS

A

IR

S

TA

TI

ON

, C

HE

RR

Y

PO

IN

T, N

C

7504546

CHRISTOPHER R LIN

PATRICK FAULKNER

FI

R

E

AL

AR

M

FI

R

ST

F

LO

O R

AR

EA

A

FA101

N8'0 16' 1/8"=1'-0"

FIRE ALARM - FIRST FLOOR - AREA A1

1 2

1 2

RJP RJP AP

12939629

AutoCAD SHX Text

29'-9" AFF

AutoCAD SHX Text

9'-4" AFF

AutoCAD SHX Text

8'-8" AFF

AutoCAD SHX Text

8'-0" AFF

AutoCAD SHX Text

8'-8" AFF

AutoCAD SHX Text

8'-8" AFF

AutoCAD SHX Text

8'-8" AFF

L M N

G H J K O P

MA

TC

HL

IN

E

- C

ON

TI

NU

ED

O N

FA

30 30

S

S

S

S

S

S

S S S S

30 30

75 75

S

WP

S

WP

S

WP

AOM

F

FADS 1

ADS 2

ADS 2ADS 2

ADS 2

ADS 2

ADS 2

AIM

AIM

TS

PS

S

WP

S

STAIR

STORAGE

STORAGE

OFFICE

STORAGE

LOBBY

BATHROOM

STORAGE

SHOP

SHOP

STAIR

BAY 1

BAY 2

OFFICE

OFFICE

OFFICE

OFFICE

SHOP

MECH.

SHOP

ADS 16

VAULT

1W

1W

1W 1W

1W

1W

F9

FMCP

DACT

MNT

F

CORRIDOR

F

FI

LE

N

RE

F:

PL

OT

D

AT

E:

7/2

1/2

6 5 :09

:01 P

M

1.0

FA

2 F

IR

E

AL

AR

M

- F

IR

ST

F

LO

OR

NE

W W

OR

K

- A

RE

A B.

DW

G

A

B

C

D

1 2 3 4 5

1 2 3

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW

SY

M

DE

SC

RI

PT

IO

N

DA

TE

AP

PR

CHK

SATISFACTORY TO

ACTIVITY

DATE

FOR COMMANDER NAVFAC

OF

EPROJECT NO.:

AS NOTED

<<PM/DM>>

BRANCH MANAGER

CHIEF ENG/ARCH

<<XX>>

4325 Lake Boone Trail|Suite 301|Raleigh, NC 27607

(984) 204-4500 | www.summerconsultants.com

SUMMER

CONSULTANTS

I N C O R P O R A T E D

4 5

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y

MC

AS

C

HE

RR

Y

PO

IN

T, N

C

CH

ER

RY

P

OI

NT

, N

C

FA

C

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

A

C Q

U

IS

IT

IO

N S

D

IV

IS

IO

N M

C

AS

C H

ER

R

Y

PO

IN

T

- C H

ER

R

Y

PO

IN

T, N C

BU

IL

DI

NG

RE

PL

AC

E

FI

RE

A

LA

RM

S

YS

TE

M

N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

C O

M M

AN

D

MA

RI

NE

C

OR

PS

A

IR

S

TA

TI

ON

, C

HE

RR

Y

PO

IN

T, N

C

7504546

CHRISTOPHER R LIN

PATRICK FAULKNER

KEY PLAN

NOT TO SCALE

KEY PLAN

N

FA102

FI

RE

A

LA

RM

FI

RS

T

FL

OO

R

AR

EA

B

RJP RJP AP

1. PROVIDE FIRE ALARM AND MASS NOTIFICATION

SYSTEM IN ACCORDANCE WITH NFPA 72 AND UFC

4-021-01.

2. PROVIDE MANUAL PAGING IN STAIRS.

3. PROVIDE COMBINATION FIRE ALARM AND MASS

NOTIFICATION CONTROL PANEL. PROVIDE MINIMUM 2

SLC, TWO AMP, AND FOUR NAC CLASS A CIRCUITS.

PROVIDE DACT WITH BOSCHE 465 COMMUNICATOR

COMBINATION PHONE AND FIBER. COORDINATE FIBER

PATCH PANEL CONNECTION.

4. PROVIDE SMOKE DETECTOR MOUNTED IN THE UNIT

ENCLOSURE FOR AHU. PROVIDE REMOTE ALARM

INDICATORS FOR ALL SMOKE DETECTORS WITH

INDICATORS NOT VISIBLE TO RESPONDING

PERSONNEL. PROVIDE REMOTE TEST STATIONS FOR

DUCT SMOKE DETECTORS.

5. PROVIDE INTELLIGIBILITY THROUGHOUT ADS 1.

6. PROVIDE AUDIBILITY THROUGHOUT ADS 2.

7. CONNECT DACT TO FIBER BATCH PANEL LOCATED IN

MECHANICAL ROOM 119 FOR COMMUNICATION

8. COORDINATE WITH BASE FIRE DEPARTMENT TO

PROVIDE EMERGENCY KEY BOX. MOUNT ACCORDING

TO MANUFACTURER SPECIFICATIONS.

9. PROVIDE AND INSTALL TAMPER SWITCH ON

SPRINKLER RISER.

GENERAL NOTES

G1. VERIFY LOCATION AND DIMENSIONS OF EXISTING

EQUIPMENT AND COORDINATE ALL WORK PRIOR TO THE

START OF CONSTRUCTION.

G2. ALL WORK SHALL BE NEW AND PROVIDED UNDER THIS

CONTRACT UNLESS SPECIFICALLY MARKED "EXISTING",

"EXIST", OR "(E)".

NOTES

1 2

N8'0 16' 1/8"=1'-0"

FIRE ALARM - FIRST FLOOR - AREA B1

12939630

AutoCAD SHX Text

8'-8" AFF

AutoCAD SHX Text

8'-8" AFF

AutoCAD SHX Text

9'-4" AFF

AutoCAD SHX Text

9'-4" AFF

AutoCAD SHX Text

9'-4" AFF

AutoCAD SHX Text

8'-8" AFF

AutoCAD SHX Text

8'-8" AFF

AutoCAD SHX Text

8'-8" AFF

AutoCAD SHX Text

8'-8" AFF

AutoCAD SHX Text

8'-0" AFF

AutoCAD SHX Text

9'-4" AFF

AutoCAD SHX Text

9'-4" AFF

AutoCAD SHX Text

8'-8" AFF

AutoCAD SHX Text

8'-8" AFF

AutoCAD SHX Text

8'-8" AFF

AutoCAD SHX Text

8'-8" AFF

AutoCAD SHX Text

20'-8" AFF

AutoCAD SHX Text

20'-8" AFF

AutoCAD SHX Text

9'-4" AFF

C D E FA B

MATCHLINE - CONTUNED ON FA104

1 2

FI

LE

N

RE

F:

PL

OT

D

AT

E:

7/2

1/2

6 5 :09

:18 P

M

1.0

FA

3 F

IR

E

AL

AR

M

- S

EC

ON

D

FL

OO

R

- N

EW

W

OR

K

- A

RE

A A.

DW

G

GENERAL NOTES

G1. VERIFY LOCATION AND DIMENSIONS OF EXISTING

EQUIPMENT AND COORDINATE ALL WORK PRIOR TO THE

START OF CONSTRUCTION.

G2. ALL WORK SHALL BE NEW AND PROVIDED UNDER THIS

CONTRACT UNLESS SPECIFICALLY MARKED "EXISTING",

"EXIST", OR "(E)".

NOTES

1. PROVIDE AIR-ASPIRATING SMOKE DETECTION SAMPLING

POINTS IN ACCORDANCE WITH UFC 3-600-01 CHAPTER 4,

NFPA 72, AND NFPA 72. THE ABOVE CEILING SPACE IS NOT

A RETURN AIR PLENUM. ROUTE PIPING/TUBING ABOVE

THE CEILING AND PLACE SAMPLE PORTS IN THE CEILING.

2. PROVIDE SCAFFOLDING FOR WORK ON 30' CEILING AND

AROUND SIMULATOR STRUCTURE.

A

B

C

D

1 2 3 4 5

1 2 3

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW

SY

M

DE

SC

RI

PT

IO

N

DA

TE

AP

PR

CHK

SATISFACTORY TO

ACTIVITY

DATE

FOR COMMANDER NAVFAC

OF

EPROJECT NO.:

AS NOTED

<<PM/DM>>

BRANCH MANAGER

CHIEF ENG/ARCH

<<XX>>

4325 Lake Boone Trail|Suite 301|Raleigh, NC 27607

(984) 204-4500 | www.summerconsultants.com

SUMMER

CONSULTANTS

I N C O R P O R A T E D

4 5

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y

MC

AS

C

HE

RR

Y

PO

IN

T, N

C

CH

ER

RY

P

OI

NT

, N

C

FA

C

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

A

C Q

U

IS

IT

IO

N S

D

IV

IS

IO

N M

C

AS

C H

ER

R

Y

PO

IN

T

- C H

ER

R

Y

PO

IN

T, N C

BU

IL

DI

NG

RE

PL

AC

E

FI

RE

A

LA

RM

S

YS

TE

M

N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

C O

M M

AN

D

MA

RI

NE

C

OR

PS

A

IR

S

TA

TI

ON

, C

HE

RR

Y

PO

IN

T, N

C

7504546

CHRISTOPHER R LIN

PATRICK FAULKNER

FI

R

E

AL

AR

M

SE

C O

N D

F

LO

O R

A

R

EA

A

FA103

N8'0 16' 1/8"=1'-0"

FIRE ALARM - SECOND FLOOR - AREA A1

RJP RJP AP

12939631

AutoCAD SHX Text

29'-9" AFF

CLASSROOM

OFFICE

OFFICE

CORRIDOR

MAIL

OFFICE

OFFICE

VAULT

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

MECH.

CORRIDOR

LOCKERS

BATHROOM

JANITORIAL

STAIR

OFFICE

OFFICE

CONFERENCE

OFFICE

OFFICE

CORRIDOR

ROOF

HIGH BAY

OPEN TO BELOW

ROOF

OFFICE

BATHROOM

L M N

G H J K

SHOWERS

CORRIDOR

OFFICE

OFFICE

OFFICE

O

HIGH BAY

OPEN TO BELOW

MA

TC

HL

IN

E

- C

ON

TI

NU

ED

O N

FA

FIRE ALARM ZONE 2

30 15 15

15 15

S

S

15 S

SS

S

15 15

S S

AOM

S S

S S

S S

ADS 2

WP

WP

30 30 15 15

ADS 2

ADS 1

S

1 2 7

S

S

F

S

FATC LOCNAP

F

S

S

S

SSS

S

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

CORRIDOR

CORRIDOR

CORRIDOR

CORRIDOR

MAIL

BATHROOM

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE177

OFFICE

CONFERENCE

S

FI

LE

N

RE

F:

PL

OT

D

AT

E:

7/2

1/2

6 5 :09

:32 P

M

1.0

FA

4 F

IR

E

AL

AR

M

- S

EC

ON

D

FL

OO

R

- N

EW

W

OR

K

- A

RE

A B.

DW

G

A

B

C

D

1 2 3 4 5

1 2 3

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW

SY

M

DE

SC

RI

PT

IO

N

DA

TE

AP

PR

CHK

SATISFACTORY TO

ACTIVITY

DATE

FOR COMMANDER NAVFAC

OF

EPROJECT NO.:

AS NOTED

<<PM/DM>>

BRANCH MANAGER

CHIEF ENG/ARCH

<<XX>>

4325 Lake Boone Trail|Suite 301|Raleigh, NC 27607

(984) 204-4500 | www.summerconsultants.com

SUMMER

CONSULTANTS

I N C O R P O R A T E D

4 5

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y

MC

AS

C

HE

RR

Y

PO

IN

T, N

C

CH

ER

RY

P

OI

NT

, N

C

FA

C

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

A

C Q

U

IS

IT

IO

N S

D

IV

IS

IO

N M

C

AS

C H

ER

R

Y

PO

IN

T

- C H

ER

R

Y

PO

IN

T, N C

BU

IL

DI

NG

RE

PL

AC

E

FI

RE

A

LA

RM

S

YS

TE

M

N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

C O

M M

AN

D

MA

RI

NE

C

OR

PS

A

IR

S

TA

TI

ON

, C

HE

RR

Y

PO

IN

T, N

C

7504546

CHRISTOPHER R LIN

PATRICK FAULKNER

KEY PLAN

NOT TO SCALE

KEY PLAN

N

FA104

FI

RE

A

LA

RM

SE

CO

ND

F

LO

OR

A

RE

A

B

RJP RJP AP

N8'0 16' 1/8"=1'-0"

FIRE ALARM - SECOND FLOOR - AREA B1

GENERAL NOTES

G1. VERIFY LOCATION AND DIMENSIONS OF EXISTING

EQUIPMENT AND COORDINATE ALL WORK PRIOR TO THE

START OF CONSTRUCTION.

G2. ALL WORK SHALL BE NEW AND PROVIDED UNDER THIS

CONTRACT UNLESS SPECIFICALLY MARKED "EXISTING",

"EXIST", OR "(E)".

NOTES

1. PROVIDE FIRE ALARM AND MASS NOTIFICATION SYSTEM IN

ACCORDANCE WITH NFPA 72 AND UFC 4-021-01.

2. PROVIDE MANUAL PAGING IN STAIRS.

3. PROVIDE NOTIFICATION APPLIANCE PANEL TO POWER

SECOND FLOOR NOTIFICATION APPLIANCES

4. PROVIDE SMOKE DETECTOR MOUNTED IN THE UNIT

ENCLOSURE FOR AHU. PROVIDE REMOTE ALARM

INDICATORS FOR ALL SMOKE DETECTORS WITH

INDICATORS NOT VISIBLE TO RESPONDING PERSONNEL

5. PROVIDE WEATHERPROOF EQUIPMENT IN BATHROOM 160,

LOCKERS 161, AND SHOWERS 162.

5. PROVIDE INTELLIGIBILITY THROUGHOUT ADS 1.

6. PROVIDE AUDIBILITY THROUGHOUT ADS 2.

7. CEILINGS ARE 8'-8" AFF EXCEPT WHERE NOTED.

12939632

AutoCAD SHX Text

9'-4" AFF

AutoCAD SHX Text

8'-0" AFF

N

RE

F:

PL

OT

D

AT

E:

7/2

1/2

6 5 :09

:48 P

M

1.0

FA

1 F

IR

E

AL

AR

M

MA

TR

IX

.D

W G

FA501

FI

RE

A

LA

RM

M

AT

RI

X

RJP RJP AP

A

B

C

D

1 2 3 4 5

1 2 3

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW

SY

M

DE

SC

RI

PT

IO

N

DA

TE

AP

PR

CHK

SATISFACTORY TO

ACTIVITY

DATE

FOR COMMANDER NAVFAC

OF

EPROJECT NO.:

AS NOTED

<<PM/DM>>

BRANCH MANAGER

CHIEF ENG/ARCH

<<XX>>

4325 Lake Boone Trail|Suite 301|Raleigh, NC 27607

(984) 204-4500 | www.summerconsultants.com

SUMMER

CONSULTANTS

I N C O R P O R A T E D

4 5

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y

MC

AS

C

HE

RR

Y

PO

IN

T, N

C

CH

ER

RY

P

OI

NT

, N

C

FA

C

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

A

C Q

U

IS

IT

IO

N S

D

IV

IS

IO

N M

C

AS

C H

ER

R

Y

PO

IN

T

- C H

ER

R

Y

PO

IN

T, N C

BU

IL

DI

NG

RE

PL

AC

E

FI

RE

A

LA

RM

S

YS

TE

M

N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

C O

M M

AN

D

MA

RI

NE

C

OR

PS

A

IR

S

TA

TI

ON

, C

HE

RR

Y

PO

IN

T, N

C

7504546

CHRISTOPHER R LIN

PATRICK FAULKNERFIRE ALARM VESDA PANEL

VE

SD

A

VE

RP

A

LE

RT

LE

D

ILL

UM

IN

AT

ES

MANUAL PULL STATION

ANNUNCIATION NOTIFICATION CONTROL

FIRE ALARM MATRIX

AL

AR

M

AN

NU

NC

IA

TI

ON

A

T

FM

CP

/F

AA

P

AN

D

SE

ND

S

TA

TU

S

TO

F

IR

E

ST

AT

IO

N

SU

PE

RV

IS

OR

Y

AN

NU

NC

IA

TI

ON

A T

FM

CP

/F

AA

P

AN

D

SE

ND

S

TA

TU

S

TO

F

IR

E

ST

AT

IO

N

TR

OU

BL

E

AN

NU

NC

IA

TI

ON

A T

FM

CP

/F

AA

P A

ND

S

EN

D

ST

AT

US

T

O

FI

RE

S

TA

TI

ON

AC

TI

VA

TE

V

IS

UA

L A

ND

A

UD

IB

LE

N

OT

IF

IC

AT

IO

N

- G

EN

ER

AL

E

VA

CU

AT

IO

N

AC

TI

VA

TE

V

IS

UA

L A

ND

A

UD

IB

LE

N

OT

IF

IC

AT

IO

N

- M

NS

SMOKE DETECTOR

TAMPER SWITCH

FACP POWER FAILURE

LOW BATTERY

OPEN CIRCUIT

GROUND FAULT

MASS NOTIFICATION INITIATION - BASE WIDE MESSAGE OR LOCAL MICROPHONE

DUCT SMOKE DETECTOR

SH

UT

D

OW

N

AS

SO

CI

AT

ED

U

NI

T

OR

P

OW

ER

T

O

SE

RV

ER

E

QU

IP

ME

NT

AC

TI

VA

TE

T

EX

TU

AL

D

IS

PL

AY

ILL

UM

IN

AT

E

"E

VA

CU

AT

E"

AC

TI

VA

TE

T

EX

TU

AL

D

IS

PL

AY

ILL

UM

IN

AT

E

"A

NN

OU

NC

EM

EN

T"

FLOW SWITCH

VE

SD

A

VE

P

FI

RE

LE

D

ILL

UM

IN

AT

ES

VE

SD

A

VE

P

AI

RF

LO

W

LE

D

ILL

UM

IN

AT

ES

VE

SD

A

VE

P

FI

LT

ER

LE

D

ILL

UM

IN

AT

ES

VE

SD

A

VE

P

PO

W

ER

LE

D

ILL

UM

IN

AT

ES

VESDA ALERT

AIR FLOW HIGH / LOW

FILTER REMOVED OR DIRTY

POWER SUPPLY OR BATTERY FAULT

VESDA FAULT

VE

SD

A

VE

P

FA

UL

T

LE

D

ILL

UM

IN

AT

ES

AL

ER

T

SI

GN

AL

T O

BU

ILD

IN

G

FM

CP

FI

RE

S

IG

NA

L T

O

BU

ILD

IN

G

FM

CP

TR

OU

BL

E

SI

GN

AL

T

O

BU

ILD

IN

G

FM

CP

VESDA ALERT SIGNAL

VESDA FIRE SIGNAL

VESDA TROUBLE SIGNAL

CARBON MONOXIDE DETECTOR

AC

TI

VA

TE

V

IS

UA

L A

ND

A

UD

IB

LE

N

OT

IF

IC

AT

IO

N

- C

AR

BO

N

MO

NO

XI

DE

SH

UT

D

OW

N

SI

MU

LA

TO

R

VESDA FIRE

12939633

N

RE

F:

PL

OT

D

AT

E:

7/2

1/2

6 5 :10

:00 P

M

1.0

FA

2.D W

G

FA502

FI

RE

A

LA

RM

R

IS

ER

RJP RJP AP

A

B

C

D

1 2 3 4 5

1 2 3

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW

SY

M

DE

SC

RI

PT

IO

N

DA

TE

AP

PR

CHK

SATISFACTORY TO

ACTIVITY

DATE

FOR COMMANDER NAVFAC

OF

EPROJECT NO.:

AS NOTED

<<PM/DM>>

BRANCH MANAGER

CHIEF ENG/ARCH

<<XX>>

4325 Lake Boone Trail|Suite 301|Raleigh, NC 27607

(984) 204-4500 | www.summerconsultants.com

SUMMER

CONSULTANTS

I N C O R P O R A T E D

4 5

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y

MC

AS

C

HE

RR

Y

PO

IN

T, N

C

CH

ER

RY

P

OI

NT

, N

C

FA

C

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

A

C Q

U

IS

IT

IO

N S

D

IV

IS

IO

N M

C

AS

C H

ER

R

Y

PO

IN

T

- C H

ER

R

Y

PO

IN

T, N C

BU

IL

DI

NG

RE

PL

AC

E

FI

RE

A

LA

RM

S

YS

TE

M

N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

C O

M M

AN

D

MA

RI

NE

C

OR

PS

A

IR

S

TA

TI

ON

, C

HE

RR

Y

PO

IN

T, N

C

7504546

CHRISTOPHER R LIN

PATRICK FAULKNER

GENERAL NOTES

G1. ALL WORK SHALL BE NEW AND PROVIDED UNDER THIS

CONTRACT UNLESS SPECIFICALLY MARKED EXISTING,

EXIST., OR (E).

G2. VERIFY LOCATION AND DIMENSIONS OF EXISTING

EQUIPMENT AND COORDINATE ALL WORK PRIOR TO

THE START OF CONSTRUCTION.

BATT

SPD

FMCP

LOBBY

FAAP

AM

P

SL

C

AN

N

AMP 1

SLC 1

FIRST FLOOR

SECOND FLOOR

AM

P

SL

C

AN

N

DACT

AIM AIM AOM

WF TS

F

S S

FATC

CORRIDOR

AMP 2

SLC 2 AOM F

NAC

S

LOC

NAP

120V

BACK TO FMCP

BACK TO FMCP

BACK TO NAP

BACK TO FMCP

HVAC

HVAC

AIM

VESDA

ROOF

S S

AOM

HVAC

BACK TO FMCP

F

WP

BACK TO FMCPNAC 1-1

NAC 1-2

NAC 2

NAC 2-1

NAC 2-2

BACK TO FMCP

BACK TO FMCP

NAP

MNT

CLASSROOM 100

MNS ANTENNA

NO SCALE

FIRE ALARM AND MASS NOTIFICATION SYSTEM RISER1

SL

C

SPD 120V

SPD 120V

NOTES

1. PROVIDE DEDICATED 120V 20 AMP CIRCUIT.

FIRE ALARM ZONE 1

FIRE ALARM ZONE 2

AMP 1

NAC 1-2

UPDC

J

CA

T6

T O

TE

LE

PH

ON

E

PA

TC

H

PA

NN

EL

SI

NG

LE

M

OD

E

FI

BE

R

TO

FI

BE

R

PA

TC

H

PA

NE

L

12939634

N

RE

F:

PL

OT

D

AT

E:

7/2

1/2

6 5 :10

:14 P

M

1.0

1.0

M

-0

.D W

G

A

B

C

D

1 2 3 4 5

1 2 3

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW

SY

M

DE

SC

RI

PT

IO

N

DA

TE

AP

PR

CHK

SATISFACTORY TO

ACTIVITY

DATE

FOR COMMANDER NAVFAC

OF

EPROJECT NO.:

AS NOTED

<<PM/DM>>

BRANCH MANAGER

CHIEF ENG/ARCH

<<XX>>

4325 Lake Boone Trail|Suite 301|Raleigh, NC 27607

(984) 204-4500 | www.summerconsultants.com

SUMMER

CONSULTANTS

I N C O R P O R A T E D

4 5

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y

MC

AS

C

HE

RR

Y

PO

IN

T, N

C

CH

ER

RY

P

OI

NT

, N

C

FA

C

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

A

C Q

U

IS

IT

IO

N S

D

IV

IS

IO

N M

C

AS

C H

ER

R

Y

PO

IN

T

- C H

ER

R

Y

PO

IN

T, N C

BU

IL

DI

NG

RE

PL

AC

E

FI

RE

A

LA

RM

S

YS

TE

M

N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

C O

M M

AN

D

MA

RI

NE

C

OR

PS

A

IR

S

TA

TI

ON

, C

HE

RR

Y

PO

IN

T, N

C

7504546

CHRISTOPHER R LIN

PATRICK FAULKNER

M-001

SY

MB

OL

S

AB

BR

EV

IA

TI

ON

S

(E)

GENERAL SYMBOLS

SYMBOLS

DUCT WITH SMOKE DETECTORSD

NORTH ARROW

COLUMN BUBBLE

DESIGNATION

REVISION CLOUD WITH REVISION

NUMBER DESIGNATION

BREAKLINE

EXISTING

POINT OF CONNECTION TO EXISTING

POINT OF TERMINATION OF REMOVAL

NOTE NUMBER

EXHAUST OR RETURN DUCT UP

EXHAUST OR RETURN DUCT DOWN

SUPPLY DUCT UP

SUPPLY DUCT DOWN

ARROW INDICATES

TRUE NORTH AND/OR

PROJECT NORTH

N

M101

N

8'0 1/8"=1'-0"

UNIQUE PLAN OR

DETAIL NUMBER

ON THIS DRAWING NORTH ARROW

NAME OF PLAN OR DETAIL

ALL DRAWINGS WHERE

DETAIL IS REFERENCED

GRAPHIC SCALE OF

PLAN OR DETAIL

2-PART REFERENCE DETAIL IDENTIFICATION:

SHEET NUMBER WHERE

DETAIL/SECTION IS DRAWN

NUMBER INDICATES

DETAIL/SECTION

FLOOR PLAN

M101, M1022

FLOOR PLAN AND DETAIL TITLES:

ROOM NUMBER DESIGNATION.1234

ZC ZC RP

12939635

Marciniak Snapshot

Marciniak Text Box 07/20/2026

MECH

(E)CONDENSING UNIT

(E)AIR HANDLING

UNIT 1

SD

(E)18x18

(E)10x10

(E)20x20

MECH.

(E)AIR HANDLING UNIT 4

(E)AIR HANDLING UNIT 2

117 119

(E)CONDENSING UNIT

SD

(E)

(E)AIR HANDLING UNIT 3 (E)ROOF ACCESS

SD

(E)12x12

(E)6x10 (E)6x12

(E)10x12

(E)FAN SECTION

(E)FILTER SECTION

(E)COIL SECTION

FI

LE

N

RE

F:

PL

OT

D

AT

E:

7/2

1/2

6 5 :11

:47 P

M

1.0

1.0

M

-1

.D W

G

A

B

C

D

1 2 3 4 5

1 2 3

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW

SY

M

DE

SC

RI

PT

IO

N

DA

TE

AP

PR

CHK

SATISFACTORY TO

ACTIVITY

DATE

FOR COMMANDER NAVFAC

OF

EPROJECT NO.:

AS NOTED

<<PM/DM>>

BRANCH MANAGER

CHIEF ENG/ARCH

<<XX>>

4325 Lake Boone Trail|Suite 301|Raleigh, NC 27607

(984) 204-4500 | www.summerconsultants.com

SUMMER

CONSULTANTS

I N C O R P O R A T E D

4 5

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y

MC

AS

C

HE

RR

Y

PO

IN

T, N

C

CH

ER

RY

P

OI

NT

, N

C

FA

C

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

A

C Q

U

IS

IT

IO

N S

D

IV

IS

IO

N M

C

AS

C H

ER

R

Y

PO

IN

T

- C H

ER

R

Y

PO

IN

T, N C

BU

IL

DI

NG

RE

PL

AC

E

FI

RE

A

LA

RM

S

YS

TE

M

N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

C O

M M

AN

D

MA

RI

NE

C

OR

PS

A

IR

S

TA

TI

ON

, C

HE

RR

Y

PO

IN

T, N

C

7504546

CHRISTOPHER R LIN

PATRICK FAULKNER

KEY PLAN

NOT TO SCALE

KEY PLAN

N M-101

FL

OO

R

PL

AN

GENERAL NOTES

NOTES

1. REMOVE SMOKE DETECTOR AND ALL ASSOCIATED

APPURTENANCES.

2. PROVIDE SMOKE DETECTOR IN SUPPLY DUCT PER NFPA 90A.

SMOKE DETECTOR SHALL INDEX THE UNIT TO OFF. REMOTE

ANNUNCIATION TO THE BUILDING FIRE ALARM SYSTEM SHALL

OCCUR PER NFPA 72.

G1. ALL WORK MUST BE NEW AND PROVIDED UNDER THIS CONTRACT

UNLESS SPECIFICALLY MARKED "EXISTING", "EXIST.", OR "(E)".

G2. VERIFY LOCATION AND DIMENSIONS OF EXISTING EQUIPMENT AND

COORDINATE ALL WORK PRIOR TO THE START OF CONSTRUCTION.

N8'0 4' 1/4"=1'-0"

(E)AIR HANDLING UNIT 1 - 1ST FLOOR1

N8'0 4' 1/4"=1'-0"

(E)AIR HANDLING UNIT 3 - 2ND FLOOR2

N8'0 4' 1/4"=1'-0"

(E)AIR HANDLING UNIT 4 - 1ST FLOOR3

M-101

M-101

M-101

ZC ZC RP

12939636

Marciniak Snapshot

Marciniak

N

RE

F:

PL

OT

D

AT

E:

7/2

1/2

6 5 :12

:01 P

M

1.0

E-

1.D W

G

A

B

C

D

1 2 3 4 5

1 2 3

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW

SY

M

DE

SC

RI

PT

IO

N

DA

TE

AP

PR

CHK

SATISFACTORY TO

ACTIVITY

DATE

FOR COMMANDER NAVFAC

OF

EPROJECT NO.:

AS NOTED

<<PM/DM>>

BRANCH MANAGER

CHIEF ENG/ARCH

<<XX>>

4325 Lake Boone Trail|Suite 301|Raleigh, NC 27607

(984) 204-4500 | www.summerconsultants.com

SUMMER

CONSULTANTS

I N C O R P O R A T E D

4 5

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y

MC

AS

C

HE

RR

Y

PO

IN

T, N

C

CH

ER

RY

P

OI

NT

, N

C

FA

C

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

A

C Q

U

IS

IT

IO

N S

D

IV

IS

IO

N M

C

AS

C H

ER

R

Y

PO

IN

T

- C H

ER

R

Y

PO

IN

T, N C

BU

IL

DI

NG

RE

PL

AC

E

FI

RE

A

LA

RM

S

YS

TE

M

N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

C O

M M

AN

D

MA

RI

NE

C

OR

PS

A

IR

S

TA

TI

ON

, C

HE

RR

Y

PO

IN

T, N

C

7504546

CHRISTOPHER R LIN

PATRICK FAULKNER

E-001

SY

MB

OL

S

AB

BR

EV

IA

TI

ON

S

ABBREVIATIONS

A AMPERES.

AF FRAME SIZE IN AMPERES.

AFF ABOVE FINISHED FLOOR.

AHU AIR HANDLING UNIT.

AT TRIP SIZE IN AMPERES.

AWG. AMERICAN WIRE GAUGE.

BLDG. BUILDING.

CAB. CABINET.

C/B CIRCUIT BREAKER.

COR CONTRACTING OFFICER REPRESENTATIVE.

CWP COLD WATER PUMP.

(D) EXISTING TO BE DEMOLISHED.

DOAS DEDICATED OUTDOOR AIR SYSTEM

DTW DUAL TEMPERATURE WATER

(E) EXISTING TO REMAIN.

EC EMPTY CONDUIT.

EMT ELECTRICAL METALLIC TUBING.

FCU FAN COIL UNIT.

FLA FULL LOAD AMPERES.

FMCP FIRE ALARM / MASS NOTIFICATION CONTROL PANEL

FVNR FULL VOLTAGE NON-REVERSING.

GRD. GROUND CONDUCTOR.

GEC GROUNDING ELECTRODE CONDUCTOR.

H-O-A HAND-OFF-AUTOMATIC

SELECTOR SWITCH.

HWP HEATING WATER PUMP.

KAIC THOUSAND AMPERE

INTERRUPTING CAPACITY.

KW KILO-WATTS.

MECH. MECHANICAL.

MDP MAIN DISTRIBUTION PANELBOARD

MH MAN HOLE

M.L.O. MAIN LUGS ONLY.

N/A NOT APPLICABLE.

N.E.C NATIONAL ELECTRICAL CODE.

NEMA NATIONAL ELECTRICAL

MANUFACTURER'S ASSOCIATION.

NFSS NON-FUSED SAFETY SWITCH.

P NUMBER OF POLES.

PH. NUMBER OF PHASES.

SUS SANDHILLS UTILITY SERVICE

TYP. TYPICAL.

TRNS MASS NOTIFICATION TRANSCEIVER

UH UNIT HEATER.

U.L. UNDERWRITER'S LABORATORIES.

UON UNLESS OTHERWISE NOTED.

V VOLTAGE.

VFD VARIABLE FREQUENCY DRIVE.

WP WEATHERPROOF, OR

NEMA 3R ENCLOSURE.

GENERAL SYMBOLS

NORTH ARROW

COLUMN BUBBLE

DESIGNATION

REVISION CLOUD WITH REVISION

NUMBER DESIGNATION

BREAKLINE

MATCHLINE DESIGNATION

NOTE NUMBER

ARROW INDICATES

TRUE NORTH AND/OR

PROJECT NORTH

N

E-101

N

8'0 1/8"=1'-0"

UNIQUE PLAN OR

DETAIL NUMBER

ON THIS DRAWING NORTH ARROW

NAME OF PLAN OR DETAIL

ALL DRAWINGS WHERE

DETAIL IS REFERENCED

GRAPHIC SCALE OF

PLAN OR DETAIL

SECTION IDENTIFICATION

INDICATES DIRECTION

OF CUTTING PLANE

NUMBER INDICATES SECTION

SHEET NUMBER WHERE

SECTION IS DRAWN

2-PART REFERENCE DETAIL IDENTIFICATION:

SHEET NUMBER WHERE

DETAIL/SECTION IS DRAWN

NUMBER INDICATES

DETAIL/SECTION

FLOOR PLAN

E-101, E-1022

FLOOR PLAN AND DETAIL TITLES:

E-101

Ø PHASE.

M A T C H L I N E A-A

ELECTRICAL SYMBOLS

E EXISTING FEEDER

M 1,3,5

BRANCH CIRCUIT CONDUIT AND CONDUCTORS RUN EXPOSED ON

WALLS AND CEILINGS. SIZE IN ACCORDANCE WITH N.E.C. RACEWAY

MUST BE MINIMUM 3/4" EMT, AND CONDUCTORS MUST BE MINIMUM

SIZE #12 AWG COPPER WITH THHN/THWN INSULATION, UNLESS

OTHER SIZES ARE SPECIFICALLY NOTED.

HOME RUN TO PANEL. NUMBER OF ARROWS INDICATE THE

NUMBER OF CIRCUITS.

NUMBER OF SLASH MARKS INDICATE THE NUMBER OF

CONDUCTORS IN RACEWAY. NO SLASH MARKS INDICATE 2

CIRCUIT CONDUCTORS PLUS A GROUND CONDUCTOR.

GREEN GROUND CONDUCTOR RUN IN RACEWAY.

PANEL NAME TO WHICH CIRCUITS RUN.

CIRCUIT BREAKERS IN PANEL SERVING THESE CIRCUITS.

WIRE SIZE IN AWG. SIZE NOT SHOWN INDICATES #12 AWG.

BRANCH CIRCUIT CONDUIT AND CONDUCTORS RUN CONCEALED

WITHIN WALLS AND CONCEALED ABOVE SUSPENDED TILE CEILINGS.

ALL OTHER BRANCH CIRCUIT CHARACTERISTICS SAME AS SHOWN

ABOVE.

#10

GENERAL NOTES

G1. VERIFY LOCATION AND DIMENSIONS OF EXISTING EQUIPMENT AND

COORDINATE ALL WORK PRIOR TO THE START OF CONSTRUCTION.

G2. ALL WORK MUST BE NEW AND PROVIDED UNDER THIS CONTRACT

UNLESS SPECIFICALLY MARKED "EXISTING", "EXIST.", OR "(E)".

G3. PERFORM ALL WORK TO UFC AND UFGS.

G4. DEFINITION (DEMOLITION DRAWINGS ONLY): DISCONNECTION AND

REMOVAL OF ASSOCIATED CONDUCTORS MUST CONSIST OF THE

REMOVAL OF THE CONDUCTORS BACK TO THE NEXT EXISTING

DEVICE TO REMAIN. PROVIDE NEW CONDUIT AND CONDUCTORS TO

RECONNECT ANY EXISTING TO REMAIN DEVICES INTERRUPTED BY

THE DEMOLITION UNDER THIS PROJECT. DISCONNECTION AND

REMOVAL OF ASSOCIATED CONDUITS MUST INCLUDE ALL EXPOSED

CONDUITS AND CONDUITS CONCEALED WITHIN DRYWALL

SURFACES…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .