J.4 Lot A2 SEED BOQ Amdt2.xls

XLS spreadsheet 560 KB Posted

Attached to
Secondary Education Expansion for Development (SEED) Rural Group 2 Activity Federal contract opportunity
Solicitation number
72061222R00005
Issued by
US Agency for International Development Malawi

About this file

This request for proposal from the US Agency for International Development solicits bids to construct 18 community day secondary schools across Malawi. The purpose is to support the Government of Malawi's commitment to increase access to secondary education.

USAID anticipates awarding up to four firm fixed price contracts totaling 25 months, including 13 months for construction and a 12-month warranty period. The sites are divided into four lots based on geography. Two large "Group A" lots of 19-20 schools each will be set aside for Malawian firms only. Two smaller "Group B" lots of six schools each will be open to international competition but restricted to Malawian firms. Offerors may bid on one or both Group A lots and one or both Group B lots.

Proposals are due within 120 days and must respond to the contents of the RFP. USAID will award the Group A lots to one or two offerors and the Group B lots to two separate offerors. Offerors should indicate the number and identifiers of lots for which they are bidding and their capacity to build multiple lots.

View the file

Other files for this federal contract opportunity

Other files attached to Secondary Education Expansion for Development (SEED) Rural Group 2 Activity, newest first.
File Type Posted
J.4 Lot A1 SEED BOQ Amdt2.xls XLS spreadsheet
J.4 Lot B1 SEED BOQ Amdt2.xls XLS spreadsheet
J.2 Lot B2_Bwangu_Amendment 02.pdf PDF
J.2 Lot B2_Mulonda_Amendment 02.pdf PDF
J.2 Lot A2 _Bolera Chiwina_Amendment 02.pdf PDF
J.2 Lot A2_Mokhotho_Amendment 02.pdf PDF
J.2 Lot A2_Khotekhote_Amendment 02.pdf PDF
J.2 Lot A2_Chinguluwe_Amendment 02.pdf PDF
J.2 Lot A2_Demera_Amendment 02.pdf PDF
J.2 Lot A1 _Chilimani_Amendment 02.pdf PDF
J.2 Lot A1 _Karopa_Amendment 02.pdf PDF
J.2 _Facility Drawings_TEACHER HOUSING_Amendment 02.pdf PDF
J.2 _Facility Drawings_CLASSROOM_Amendment 02.pdf PDF
J.2 _Facility Drawings_TEACHER LATRINE_Amendment 02.pdf PDF
J.2 _Facility Drawings_STUDENT LATRINE_Amendment 02.pdf PDF
SRG2 Pre-Bid Meeting Presentation.pdf PDF
L2.A (Template 2.A) - USAID - CV Biography.docx DOCX document
J11 IEE SRG2 FINAL.pdf PDF
J9 Monthly Report Template SRG2 FINAL.pdf PDF
J7 Child Safeguarding SRG2 FINAL.pdf PDF
J6 MCHINJI ESMP REPORT.pdf PDF
J6 RUMPHI ESMP REPORT.pdf PDF
J6 KARONGA ESMP REPORT.pdf PDF
J6 CHIKWAWA ESMP REPORT.pdf PDF
J6 NTCHISIC ESMP REPORT.pdf PDF
J.2 Site Packages Lot B2 SEED_Samson.pdf PDF
J.2 Site Packages Lot B2 SEED_Kandeu.pdf PDF
J.2 Site Packages Lot B1 SEED_Chunzu.pdf PDF
J.2 Site Packages Lot B1 SEED_Fanuel.pdf PDF
J.2 Site Packages Lot B1 SEED_Mwangala.pdf PDF
J.2 Site Packages Lot A2 SEED_Dzundu.pdf PDF
J.2 Site Packages Lot A2 SEED_Mokhotho.pdf PDF
J.2 Site Packages Lot A2 SEED_Tambala.pdf PDF
J.2 Site Packages Lot A2 SEED_Mwalawang_ombe.pdf PDF
J.2 Site Packages Lot A1 SEED_Lupachi.pdf PDF
J.2 Site Packages Lot A1 SEED_Chibweya.pdf PDF
J.2 Site Packages Lot A1 SEED_Ipyana.pdf PDF
J.2 Site Packages Lot A1 SEED_Kambira.pdf PDF
J.2 Site Packages Lot A1 SEED_Matunkha.pdf PDF
J.2 Site Packages Lot A1 SEED_Mpapa.pdf PDF
J.2 Site Packages Lot A1 SEED_Kasipa.pdf PDF
J2 Facility Drawings_STANDARD DRAWINGS.pdf PDF
J1 Site Locations SRG2 FINAL.pdf PDF
J.2 Site Packages Lot A1 SEED_Mayoka.pdf PDF
L1.B (Template 1.B) - Financial Questionnaire.docx DOCX document
L1.C (Template 1.C) - Surety Form.docx DOCX document
J10 Bank Guarantee Template SRG2 final.pdf PDF
J8. PM Plan Template SRG2 FINAL.docx DOCX document
J6 MANGOCHI ESMP REPORT.pdf PDF
J6 NSANJE ESMP REPORT.pdf PDF
Show all 50

Secondary Education Expansion for Development (SEED) Rural Group 2 Activity has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Lot A2

Project:SEED Rural, SRG2 -Amendment 2Schedule Summary
Bid Date:___________________________________Lot A2
Name of Bidder:___________________________________
DescriptionSchedule Total
1. Facility Construction
Line 1Classroom Block ASchedule A Total$ - 0
Line 2Classroom Block BSchedule A Total$ - 0
Line 3Science ClassroomSchedule B Total$ - 0
Line 4Teacher Housing and Pit Latrine, Block ASchedule C Total$ - 0
Line 5Teacher Housing and Pit Latrine, Block BSchedule C Total$ - 0
Line 6Male and Female Pit LatrinesSchedule D Total$ - 0
Line 7Teacher Pit LatrineSchedule E Total$ - 0
Line 8Facility Sub-Total (Add Lines 1-7)$ - 0
Line 9Number of Facilities in Lot A220
Line 10Total Facility Bid (Multiply Line 8 x Line 9)$ - 0
2. Mobilization and Site Work
Line 11LulangaSCHEDULE F20$ - 0
Line 12MtimabiSCHEDULE F21$ - 0
Line 13MandimbaSCHEDULE F22$ - 0
Line 14LuwalikaSCHEDULE F23$ - 0
Line 15MkombeSCHEDULE F24$ - 0
Line 16ChitimbeSCHEDULE F25$ - 0
Line 17DzunduSCHEDULE F26$ - 0
Line 18MlindiSCHEDULE F27$ - 0
Line 19ChiwambeSCHEDULE F28$ - 0
Line 20MichuluSCHEDULE F29$ - 0
Line 21KhotekhoteSCHEDULE F30$ - 0
Line 22ChinguluweSCHEDULE F31$ - 0
Line 23DemeraSCHEDULE F32$ - 0
Line 24MkangaSCHEDULE F33$ - 0
Line 25NthuluSCHEDULE F34$ - 0
Line 26Bolera ChiwinaSCHEDULE F35$ - 0
Line 27Mwalawang'ombeSCHEDULE F36$ - 0
Line 28KaliraSCHEDULE F37$ - 0
Line 29TambalaSCHEDULE F38$ - 0
Line 30MokhothoSCHEDULE F39$ - 0
Line 31Total Mobilization and Site Work Bid (Add Lines 11-30)$ - 0
3. Extra Work
Line 32Total Extra Work BidSchedule G$ - 0
Grand Total Construction Cost Lot A2 (Add Lines 10, 31 and 32) …........................................................................................................$ - 0
Line 33Performance Bond with value equal to 25% of the Grand Total Construction Cost is required. Enter Cost of this Performance Bond
Grand Total Lot A2 Including Performance Bond (Add Lines 10, 31, 32 and 33) …........................................................................................................$ - 0
Written Grand Total Including Bond: _____________________________________________________________
_____________________________________________________________________________________Dollars and ___________________Cents

Sch A Classroom

Project:SEED RuralBILL OF QUANTITIESSCHEDULE A
Bid Date:______________________________________________________CLASSROOM BUILDINGS2 Each
Name of Bidder:______________________________________________________
Bid SectionBid ItemDescriptionSpecification SectionQuantityUnitUnit PriceBid Item ExtensionSection Subtotal
1.00Concrete Work, Foundation and Slab
1.01Structural Excavation for building foundations, includes 10% for over-excavation.31 20 0024.00Cubic Meter- 0
1.02Termite Control31 31 161.00Lump Sum- 0
1.03Lean Concrete under reinforced concrete , Class 10/12 MPa03 30 0010.50Cubic Meter- 0
1.04Hard-Core under Exterior Slab31 20 0014.00Cubic Meter- 0
1.05Sand Blinding on Hard-Core Under Exterior Slab31 20 002.40Cubic Meter- 0
1.06Grade Beams, Reinforced Concrete, Class C-20/2503 30 3018.25Cubic Meter- 0
1.07Interior Floor Slab, Reinforced Concrete, Class C-20/2503 30 3021.00Cubic Meter- 0
1.08Concrete Formwork, Ground Contact03 30 3039.50Square Meter- 0
1.09Waterproofing Membrane, Poly Sheet 250 Micron including overlap03 30 30273.00Square Meter- 0
1.10Saw-Cut Control Joints03 30 3050.00Meter- 0
1.11Interior Floor Slab, Reinforcing Wire Mesh, A9803 30 30311.00Square Meter- 0
Amdt21.12Grade Beam Reinforcing Steel, Grade 45003 30 301,100.00Kilogram- 0
1.13Expansion Joint Material, Bitumen Impregnated, 12mm thickness03 30 3011.00Square Meter- 0
1.14Structural Backfill, Select Material from On-Site31 20 0012.00Cubic Meter- 0
1.16External Concrete Walkway, Stoops & Ramps, Class C-20/2503 30 308.00Cubic Meter- 0
1.17Reinforcing Wire Mesh in External Walkway, Stoops and Ramps, A98 Including overlap03 30 3072.00Square Meter- 0
1.18External Concrete Drainage Apron, INCLUDING A98 Reinforcing Wire, Stoop Drainage, Class C-20/2532 13 1340.00Square Meter- 0
Sub-Total- 0
2.00Concrete Work, Structure
2.01Reinforced Concrete in Columns, Class C-20/25 with exposed surfaces finshed appropriate for location03 30 301.20Cubic Meter- 0
2.02Reinforced Concrete in Bond Beams, Class C-20/25 with exposed surfaces finished appropriate for location.03 30 304.50Cubic Meter- 0
2.03Concrete(steel or timber) formwork for Bond Beams03 30 3073.00Square Meter- 0
2.04Reinforcing Steel in Bond Beams and Columns, Grade 45003 30 30774.00Kilogram- 0
2.05Anchor Bolts, 16mm Dia x 200mm long with 50mm tall and Heavy Duty Washer welded to plate and Painted after installation. Includes Leveling Grout.05 50 00128.00Pieces- 0
2.06Reinforcing Steel in Hollow Core Block at Truss Support Points, Grade 45003 30 30335.00Kilogram- 0
Sub-Total- 0
3.00Masonry Work
Amdt23.01Hollow Core Concrete Block, Class AAA (5.0MPa), 200mm thickness. DPC under exterior walls per detail on Sheet DS-501 and Horizontal Wire Reinforcing where indicated.Div 4198.00Square Meter- 0
3.02Hollow Core Concrete Block, Class AAA (5.0MPa), 150mm thicknessDiv 4- 0Square Meter- 0
3.03Mortar in Hollow Core Block at Truss Support PointsDiv 46.00Cubic Meter- 0
3.04Terrazzo Window Sill, Chamfered with Drip LedgeDiv 418.20Meter- 0
3.05Masonry Pointing, ExteriorDiv 4167.00Square Meter- 0
Sub-Total- 0
4.00Structural Steel
4.01Truss, Type 1 Welded, Bolted, Erected, Primer with 2-Coats of Synthetic Enamel PaintDivision 05; 09 91002.00Pieces- 0
4.02Truss, Type 2 Welded, Bolted, Erected, Primer with 2-Coats of Synthetic Enamel PaintDivision 05; 09 91008.00Pieces- 0
4.03Truss, Type 3 Welded, Bolted, Erected, Primer with 2-Coats of Synthetic Enamel PaintDivision 05; 09 91001.00Pieces- 0
4.04Rafter R1, Welded and Erected, Primer with 2-Coats of Synthetic Enamel PaintDivision 05; 09 91003.00Pieces- 0
4.05Purlins Cold Formed with Connection Angle , Bolts and Erected, 125 x 50 x 20 x 2.5mm, primed, erected and painted with two coats of sythetic enamel paintDivision 05; 09 9100314.00M- 0
4.07Fascia Bracing, Welded, Primed, Painted and ErectedDivision 05; 09 9100490.00Kilogram- 0
4.08Misc. Steel for Bracing and Supports, Painted and ErectedDivision 05; 09 9100410.00Kilogram- 0
Sub-Total- 0
5.00Carpentry and Joinery
Amdt25.01Wood or Cementitious, or other approved Fascia Board w Prime Coat and 2 Coats Alkyd Varnish all Sides, 30 CM Tall06 10 00, 06, 20 00, 09 91 0084.00Meter- 0
5.02Suspended Ceiling System, Interior PVC with Insulation including in the Clear story with 25 x 50mm CFM purlin support Grid06 10 00, 06, 20 00, 09 91 00210.00Square Meter- 0
Amdt25.03Soffit and Exterior Closure System Including Clearstory, PVC with wood support grid and Soffit Vents06 10 00, 06, 20 00, 09 91 0081.00Square Meter- 0
Amdt25.04Ceiling and clearstory Corner Trim, Interior, PVC06 10 00, 06, 20 00, 09 91 0097.00Meter- 0
Amdt25.05Soffit Corner Trim, Exterior, PVC06 10 00, 06, 20 00, 09 91 0020.50Meter- 0
5.06Masonry Screen wall, pointed to match exterior of buildingDivision 0429.00Square Meter- 0
Amdt25.07Clearstory Interior Vertical Enclosure System with Metal Studs, Double PVC Cladding, fixed in place06 10 00, 06, 20 00, 09 91 00203.00Square Meter- 0
Amdt25.08Clearstory Partition between Office and Classroom, Single PVC Cladding on both Sides, Insullation, fixed in place (Det 3/CA-401)06 10 00, 06, 20 00, 09 91 0010.00Square Meter- 0
6.00Roofing, Gutters & Misc. Metals Sum
6.01Steel Roof Panels Sum with fasteners in place, Pepainted 26 gage, Purchase and delivery, warrantyDivisions 05, 07289.00Square Meter- 0
Amdt26.02Shaped Metal Trim Flashing installed with anchors at maximum 40cm spacing, Galvanized, primed and painted with 2 coats of synthetic enamel, Development Length 500mmDivisions 05, 0741.00Meter- 0
Amdt26.03PVC Roof GutterDivisions 05, 078.00Meter- 0
6.04PVC Roof Gutter DownspoutsDivisions 05, 073.00Meter- 0
Amdt26.05Clearstory and Gable Closure, Painted Exterior Corrugated Metal Cladding with Stud Framing, Drip Flashing, Complete fixed in placeDivisions 05, 0748.00Square Meter- 0
6.06Metal Roof Cap Prepainted, 26 gage with warrantyDivisions 05, 074.60Meter- 0
Sub-Total- 0
7.00Doors & Windows
7.01Door, Steel, Double Sided, 800 x 2050mm D1 Installed with Fixtures, Primer plus 2 Coats of synthetic enamel05 50 00, Divisions 08, 095.00Pieces- 0
7.05Door Frame, Steel with Skylight and Security Bars, F3 900x2800mm Installed with Fixtures, Caulking, Primer plus 2 Coats of synthetic enamel05 50 00, Divisions 08, 095.00Pieces- 0
7.10Window Double Steel, Installed, W5, 1200 x 1725mm with Grill, Fixtures, Caulking, Primed with 2 Coats of synthetic enamel05 50 00, Divisions 08, 0914.00Pieces- 0
7.14Louver, Steel with Steel Frame, Installed L1, 4475 x 1000mm, Insect Screen, primed with two Coats of synthetic enamel05 50 00, Divisions 08, 092.00Pieces- 0
7.15Louver, Steel with Steel Frame, Installed L2 2075 x 1000mm, Insect Screen, primed with two Coats of synthetic enamel05 50 00, Divisions 08, 092.00Pieces- 0
7.16Louver, Steel with Steel Frame, Installed L3, 3805 x 1000mm, Insect Screen, primed with two Coats of synthetic enamel05 50 00, Divisions 08, 091.00Pieces- 0
7.19Louver, Steel with Steel Frame, Installed L6, 4890 x 600mm, Insect Screen, primed with two Coats of synthetic enamel05 50 00, Divisions 08, 092.00Pieces- 0
7.20Louver, Steel with Steel Frame, Installed L7, 1400 x 500mm, Insect Screen, primed with two Coats of synthetic enamel05 50 00, Divisions 08, 092.00Pieces- 0
7.21Louver/Window, Steel with Steel Frame, Installed S1, 4475 x 300mm, Insect Screen, primed with two Coats of synthetic enamel05 50 00, Divisions 08, 092.00Pieces- 0
7.22Louver/Window, Steel with Steel Frame, Installed S2, 2075 x 300mm, Insect Screen, primed with two Coats of synthetic enamel05 50 00, Divisions 08, 092.00Pieces- 0
7.23Louver/Window, Steel with Steel Frame, Installed S3, 3805 x 300mm, Insect Screen, primed with two Coats of synthetic enamel05 50 00, Divisions 08, 091.00Pieces- 0
7.29Glazing, 5 mm, Frosted/Opaque, Installed08 80 007.60Square Meter- 0
7.30Glazing, 5 mm, Clear, Installed08 80 0025.50Square Meter- 0
Sub-Total- 0
8.00Finishing
8.01Internal Wall Plastering, Two Coats Cement/Sand Mortar09 91 00250.00Square Meter- 0
8.02Internal Wall Surface, Final Coat Gypsum Plaster09 91 00250.00Square Meter- 0
8.04Floor Mortar Screed, Smooth with 2 Coats sealer, 35mm Thick09 91 0022.40Square Meter- 0
8.05Plastic Emulsion Paint, Three Coats (Interior)09 91 00240.00Square Meter- 0
Sub-Total- 0
9.00SpecialtiesDiv 10, 12, 15
9.01Signage, Aluminum Placard with Vinyl Cover and Lettering3.00Pieces- 0
9.02Fire Extinguisher, 9 Kilogram Mounted with compatible bracket and "Fire Extinguisher" Signage.3.00Pieces- 0
Amdt29.03Authentic Slate or Porcelain Steel Chalk Board with with Aluminum Surround and Aluminum Tray, fixed to wall. Board color to be approved.8.60Square Meter- 0
Amdt29.04Porcelain Steel Marker Board with Aluminum Surround and Aluminum tray, fixed to wall. Board color to be approved13.40Square Meter- 0
Amdt29.05Tack Board with Aluminum Surround and Aluminum Tray Fixed to wall12.80Square Meter- 0
Sub-Total- 0
10.00Electrical Rough-In
Amdt210.01Secondary Distr. Board Flush Mtd, 24 space, lockable door with out circuit breakers, including (2 x 21mm) conduit to ceiling within masonry and (1 x 35mm) conduit through the Grade Beam and terminated with a plug at 2 meters from face of building.Division 261.00Pieces- 0
10.02Conduit only with pull string for electric wire, Inside masonry, 21mm PVCDivision 26150.00Meter- 0
10.03Light Switch Box Only, Installed in Masonry with Blank CoverDivision 265.00Pieces- 0
10.04Outlet Socket Box Only Installed in Masonry with Blank CoverDivision 2612.00Pieces- 0
10.05Exterior Wall light Box Only Installed in Masonry with Blank CoverDivision 2612.00Pieces- 0
Amdt210.06Interior Light Fixture Box Only Mounted in PVC Ceiling Panels with Blank CoverDivision 2616.00Pieces- 0
Sub-Total- 0
SCHEDULE TOTAL- 0

Sch B Science Bld

Project:SEED RuralBILL OF QUANTITIESSCHEDULE B
Bid Date:______________________________________________________SCIENCE CLASSROOM1 EACH
Name of Bidder:______________________________________________________
Bid SectionBid ItemDescriptionSpecification SectionQuantityUnitUnit PriceExtensionSection Subtotal
1.00Concrete Work, Foundation
1.01Structural Excavation for building foundations, includes 10% for over-excavation.31 20 0012.60Cubic Meter- 0
1.02Termite Control31 31 161.00Lump Sum- 0
1.03Lean Concrete under reinforced concrete , Class 10/12 MPa03 30 007.10Cubic Meter- 0
1.04Hard-Core under Exterior Slab31 20 006.50Cubic Meter- 0
1.05Sand Blinding on Hard-Core Under Exterior Slab31 20 001.70Cubic Meter- 0
1.06Grade Beams, Reinforced Concrete, Class C-20/2503 30 3011.50Cubic Meter- 0
1.07Interior Floor Slab, Reinforced Concrete, Class C-20/2503 30 3014.20Cubic Meter- 0
1.08Concrete formwork, Ground Contact03 30 3027.00Square Meter- 0
1.09Waterproofing Membrane, Poly Sheet 250 Micron including overlap03 30 30185.00Square Meter- 0
1.10Saw-Cut Control Joints03 30 3029.00Meter- 0
1.11Interior Floor Slab, Reinforcing Wire Mesh, A9803 30 30142.00Square Meter- 0
Amdt21.12Grade Beam Reinforcing Steel, Grade 45003 30 30903.00Kilogram- 0
1.13Expansion Joint Material, Bitumen Impregnated, 12mm thickness03 30 306.00Square Meter- 0
1.14Structural Backfill, Select Material from On-Site03 30 308.00Cubic Meter- 0
1.16External Concrete Walkway, Stoops & Ramps, Class C-20/2503 30 304.30Cubic Meter- 0
1.17Reinforcing Wire Mesh in External Walkway, Stoops and Ramps, A98 Including overlap03 30 3045.00Square Meter- 0
1.18External Concrete Drainage Apron, INCLUDING A98 Reinforcing Wire, Stoop Drainage, Class C-20/2503 30 3024.00Square Meter- 0
Sub-Total- 0
2.00Concrete Work, Structure
2.01Reinforced Concrete in Columns, Class C-20/25 with exposed surfaces finshed appropriate for location03 30 300.30Cubic Meter- 0
2.02Reinforced Concrete in Bond Beams, Class C-20/25 with exposed surfaces finished appropriate for location.03 30 303.10Cubic Meter- 0
2.03Concrete(steel or timber) formwork for Bond Beams03 30 3036.00Square Meter- 0
2.04Reinforcing Steel in Bond Beams and Columns, Grade 45003 30 30560.00Kilogram- 0
2.05Anchor Bolts, 16mm Dia x 200mm long with 50mm Tall and Heavy Duty Washer welded to plate and Painted after installation. Includes Leveling Grout.05 50 0084.00Pieces- 0
2.06Reinforcing Steel in Hollow Core Block at Truss Support Points, Grade 45003 30 30213.00Kilogram- 0
Sub-Total- 0
3.00Masonry Work
Amdt23.01Hollow Core Concrete Block, Class AAA (5.0MPa), 200mm thickness. DPC under exterior walls per detail on Sheet DS-501 and Horizontal Wire Reinforcing where indicated.Division 4132.00Square Meter- 0
3.02Hollow Core Concrete Block, Class AAA (5.0MPa), 150mm thicknessDivision 414.00Square Meter- 0
3.03Mortar in Hollow Core Block at Truss Support PointsDivision 43.50Cubic Meter- 0
3.04Terrazzo Window Sill, Chamfered with Drip LedgeDivision 427.60Meter- 0
3.05Masonry Pointing, ExteriorDivision 488.00Square Meter- 0
Sub-Total- 0
4.00Structural Steel
4.01Truss, Type 1 Welded, Bolted, Erected, Primer with 2-Coats of Synthetic Enamel PaintDivision 05; 09 91003.00Pieces- 0
4.02Truss, Type 2 Welded, Bolted, Erected, Primer with 2-Coats of Synthetic Enamel PaintDivision 05; 09 91004.00Pieces- 0
4.05Purlins Cold Formed with Connection Angle , Bolts and Erected, 125 x 50 x 20 x 2.5mm, primed, erected and painted with two coats of sythetic enamel paintDivision 05; 09 9100148.00Meter- 0
4.07Fascia Bracing, Welded, Painted and ErectedDivision 05; 09 9100190.00Kilogram- 0
4.08Misc. Steel for Bracing and Supports, Painted and ErectedDivision 05; 09 9100570.00Kilogram- 0
Sub-Total- 0
5.00Carpentry and Joinery
Amdt25.01Wood or Cementitious, or other approved Fascia Board w Prime Coat and 2 Coats Alkyd Varnish all Sides, 30 CM Tall06 10 00, 06, 20 00, 09 91 0032.00Meter- 0
5.02Suspended Ceiling System, Interior PVC with Insulation including in the Clear story with 25 x 50mm CFM purlin support Grid06 10 00, 06, 20 00, 09 91 00142.00Square Meter- 0
Amdt25.03Soffit and Exterior Closure System Including Clearstory, PVC with wood support grid and Soffit Vents06 10 00, 06, 20 00, 09 91 0036.00Square Meter- 0
Amdt25.04Ceiling and clearstory Corner Trim, Interior, PVC06 10 00, 06, 20 00, 09 91 0041.00Meter- 0
Amdt25.05Soffit Corner Trim, Exterior, PVC06 10 00, 06, 20 00, 09 91 0022.00Meter- 0
5.06Masonry Screen wall, sealed to match exterior of buildingDivision 0414.60Square Meter- 0
Amdt25.07Clearstory Interior Vertical Enclosure System with Metal Studs, Double PVC Cladding, fixed in place06 10 00, 06, 20 00, 09 91 0047.50Square Meter- 0
5.08Concrete Counter 60.2 cm wide x 90 cm high, with Supports at 1.5m, Smooth Finish with 2 Coats of Concrete SealerDivision 0422.00Meter- 0
5.09Concrete Counter Fascia framework and doors, 90cm high, 20mm Plywood, paint, hardware with interior bottom and mid-shelves06 20 00, 09 91 0021.00Meter- 0
Sub-Total- 0
6.00Roofing, Gutters & Misc. Metals Sum
6.01Steel Roof Panels Sum with fasteners in place, Prepainted 26 gage, Purchase and delivery, warrantyDivisions 05, 07187.00Square Meter- 0
Amdt26.02Shaped Metal Trim Flashing installed with anchors at maximum 40cm spacing, Galvanized, primed and painted with 2 coats of synthetic enamel, Development Length 500mmDivisions 05, 0732.00Meter- 0
Amdt26.05Clearstory and Gable Closure, Painted Exterior Corrugated Metal Cladding with Stud Framing, Drip Flashing, Complete fixed in placeDivisions 05, 0729.50Square Meter- 0
6.06Metal Roof Cap Prepainted, 26 gageDivisions 05, 077.20Meter- 0
Sub-Total- 0
7.00Doors & Windows
7.01Door, Steel, Double Sided, 800 x 2050mm D1 Installed with Fixtures, Primer plus 2 Coats of Oil-Based Paint05 50 00, Divisions 08, 095.00Pieces- 0
7.03Door Frame, Steel with Skylight F1 900x2800mm Installed with Fixtures, Caulking, Primer plus 2 Coats of Oil Based Paint05 50 00, Divisions 08, 092.00Pieces- 0
7.05Door Frame, Steel with Skylight and Security Bars, F3 900x2800mm Installed with Fixtures, Caulking, Primer plus 2 Coats of Oil Based Paint05 50 00, Divisions 08, 093.00Pieces- 0
7.06Window Steel, Installed, W1, 600 x 1725mm with Grill, Fixtures, Caulking, Primed with 2 Coats of Oil-Based Paint05 50 00, Divisions 08, 096.00Pieces- 0
7.09Window Steel, Installed, W4, 600 x 725mm with Grill, Fixtures, Caulking, Primed with 2 Coats of Oil-Based Paint05 50 00, Divisions 08, 091.00Pieces- 0
7.11Window Double Steel, Installed, W6, 1200 x 1325mm with Grill, Fixtures, Caulking, Primed with 2 Coats of Oil-Based Paint05 50 00, Divisions 08, 096.00Pieces- 0
7.17Louver, Steel with Steel Frame, Installed L4, 2400 x 1000mm, Insect Screen, primed with two Coats of synthetic enamel05 50 00, Divisions 08, 092.00Pieces- 0
7.18Louver, Steel with Steel Frame, Installed L5, 2600 x 1000mm, Insect Screen, primed with two Coats of synthetic enamel05 50 00, Divisions 08, 091.00Pieces- 0
7.19Louver, Steel with Steel Frame, Installed L6, 4890 x 600mm, Insect Screen, primed with two Coats of synthetic enamel05 50 00, Divisions 08, 092.00Pieces- 0
7.24Louver/Window, Steel with Steel Frame, Installed S4, 2400 x 300mm, Insect Screen, primed with two Coats of synthetic enamel05 50 00, Divisions 08, 092.00Pieces- 0
7.25Louver/Window, Steel with Steel Frame, Installed S5, 2600 x 300mm, Insect Screen, primed with two Coats of synthetic Enamel05 50 00, Divisions 08, 091.00Pieces- 0
7.29Glazing, 5 mm, Frosted/Opaque, Installed08 80 004.80Square Meter- 0
7.30Glazing, 5 mm, Clear, Installed08 80 0016.00Square Meter- 0
Sub-Total- 0
8.00Finishing
8.01Internal Wall Plastering, Two Coats Cement/Sand Mortar09 91 00198.00Square Meter- 0
8.02Internal Wall Surface, Final Coat Gypsum Plaster09 91 00198.00Square Meter- 0
8.05Plastic Emulsion Paint, Three Coats (Interior)09 91 00198.00Square Meter- 0
Sub-Total- 0
9.00SpecialtiesDiv 10, 12, 15
9.01Signage, Aluminum Placard with Vinyl Cover and Lettering3.00Pieces- 0
9.02Fire Extinguisher, 9 Kilogram Mounted with compatible bracket and "Fire Extinguisher" Signage.3.00Pieces- 0
Amdt29.03Authentic Slate or Porcelain Steel Chalk Board with with Aluminum Surround and Aluminum Tray, fixed to wall. Board color to be approved.4.30Square Meter- 0
Amdt29.04Porcelain Steel Marker Board with Aluminum Surround and Aluminum tray, fixed to wall. Board color to be approved- 0Square Meter- 0
Amdt29.05Tack Board with Aluminum Surround and Aluminum Tray Fixed to wall4.00Square Meter- 0
Amdt29.06Stainless Steel Laboratory sink, 18 gage (1.2mm) inside dimensions 600 mmx 400mm x 200mm deep, Elkay DPMSR1272221 or equal. Install trap provided with sink for plumbing connection by others. Include temporary plywood cover fixed in place with 2 coats of enamel paint10.00Pieces- 0
Sub-Total- 0
10.00Electrical Rough-In
Amdt210.01Secondary Distr. Board Flush Mtd, 24 space, lockable door with out circuit breakers, including (2 x 21mm) conduit to ceiling within masonry and Exterior Rated Meter Base with (2 x 35mm) conduit terminated undergound w plug at 2 meters from face of building. Det 4/DE510Division 261.00Pieces- 0
10.02Conduit only with pull string for electric wire, Inside masonry, 21mm PVCDivision 2680.00Meter- 0
Amdt210.03Light Switch Box Only, Installed in Masonry with Blank CoverDivision 267.00Pieces- 0
10.04Outlet Socket Box Only Installed in Masonry with Blank CoverDivision 2615.00Pieces- 0
10.05Wall mounted light Box Only Installed in Masonry with Blank CoverDivision 263.00Pieces- 0
Amdt210.06Interior Light Fixture Box Only Mounted in PVC Ceiling Panels with Blank CoverDivision 2611.00Pieces- 0
Sub-Total- 0
SCHEDULE TOTAL- 0

Sch C Residence

Project:SEED RuralBILL OF QUANTITIESSCHEDULE C
Bid Date:______________________________________________________TEACHER HOUSING AND PIT LATRINE2 Each
Name of Bidder:______________________________________________________
Bid SectionBid ItemDescriptionSpecification SectionQuantityUnitUnit PriceExtensionSection Subtotal
1.00Concrete Work, Foundation
1.01Structural Excavation for building foundations, includes 10% for over-excavation.31 20 0048.00Cubic Meter- 0
1.02Termite Control31 31 161.00Lump Sum- 0
1.03Lean Concrete under reinforced concrete , Class 10/12 MPa03 30 006.20Cubic Meter- 0
1.04Hard-Core under Exterior Slab31 20 006.60Cubic Meter- 0
1.05Sand Blinding on Hard-Core Under Exterior Slab31 20 001.70Cubic Meter- 0
1.06Grade Beams, Reinforced Concrete, Class C-20/2503 30 3013.70Cubic Meter- 0
1.07Interior Floor Slab, Reinforced Concrete, Class C-20/2503 30 3013.80Cubic Meter- 0
1.08Concrete formwork, Ground Contact03 30 3042.00Square Meter- 0
1.09Waterproofing Membrane, Poly Sheet 250 Micron including overlap03 30 30160.00Square Meter- 0
1.10Saw-Cut Control Joints03 30 3023.00Meter- 0
1.11Interior Floor Slab, Reinforcing Wire Mesh, A9803 30 30123.00Square Meter- 0
1.12Grade Beam Reinforcing Steel, Grade 45003 30 30952.00Kilogram- 0
1.13Expansion Joint Material, Bitumen Impregnated, 12mm thickness03 30 303.30Square Meter- 0
1.14Structural Backfill, Select Material from On-Site03 30 3025.00Cubic Meter- 0
1.15Hard-Core Drainage Material around Latrine Pit31 20 006.50Cubic Meter- 0
1.16External Concrete Walkway, Stoops & Ramps, Class C-20/2503 30 303.50Cubic Meter- 0
1.17Reinforcing Wire Mesh in External Walkway, Stoops and Ramps, A98 Including overlap03 30 3025.00Square Meter- 0
1.18External Concrete Drainage Apron, INCLUDING A98 Reinforcing Wire, Stoop Drainage, Class C-20/2403 30 3024.00Square Meter- 0
Sub-Total- 0
2.00Concrete Work, Structure
2.01Reinforced Concrete in Columns, Class C-20/25 with exposed surfaces finshed appropriate for location03 30 301.40Cubic Meter- 0
2.02Reinforced Concrete in Bond Beams, Class C-20/25 with exposed surfaces finished appropriate for location.03 30 305.90Cubic Meter- 0
2.03Concrete(steel or timber) formwork for Bond Beams03 30 3057.00Square Meter- 0
2.04Reinforcing Steel in Bond Beams and Columns, Grade 45003 30 30903.00Kilogram- 0
2.05Anchor Bolts, 16mm Dia x 200mm long with 50mm tall and Heavy Duty Washer welded to plate and Painted after installation. Includes Leveling Grout.03 30 3084.00Pieces- 0
Sub-Total- 0
3.00Masonry Work
Amdt23.01Hollow Core Concrete Block, Class AAA (5.0MPa), 200mm thickness. DPC under exterior walls per detail on Sheet DS-501Division 4189.00Square Meter- 0
3.02Hollow Core Concrete Block, Class AAA (5.0MPa), 150mm thicknessDivision 419.00Square Meter- 0
3.03Mortar in Hollow Core BlockDivision 43.10Cubic Meter- 0
3.04Terrazzo Window Sill, Chamfered with Drip LedgeDivision 412.60Meter- 0
3.05Masonry Pointing, ExteriorDivision 4174.00Square Meter- 0
3.06Concrete LintelDivision 43.00M- 0
Sub-Total- 0
4.00Structural Steel
4.06Purlins Cold Formed with Connection Angle , Bolts and Erected, 75 x 50 x 20 x 2.5mm, primed, erected and painted with 2 coats of synthetic enamel paintDivision 05; 09 9100140.00M- 0
4.07Fascia Bracing, Welded, Painted and ErectedDivision 05; 09 9100180.00Kilogram- 0
4.08Misc. Steel for Bracing and Supports, Painted and ErectedDivision 05; 09 910080.00Kilogram- 0
4.09Teacher Housing Roofing System, Complete with all Structural Sections, Connections, Welding, Erection. Primed and Painted with 2 Coats of Oil-Based Paint, Less Purlins and Anchor BoltsDivision 05; 09 91002,200.00Kilogram- 0
4.10Teacher Pit Latrine Roofing System, Wood, Complete with all Structural Sections, Connections. Primed and Painted with 2 Coats of Oil-Based Paint, Including Purlins and Anchor StrapsDivision 61.00Lump Sum- 0
Sub-Total- 0
5.00Carpentry and Joinery
5.01Wood Fascia Board w Prime Coat and 2 Coats Oil Based Paint all Sides, 30 CM Tall06 10 00, 06, 20 00, 09 91 0050.00Meter- 0
5.02Suspended Ceiling System, Interior PVC with Insulation including in the Clear story with 25 x 50mm CFM purlin support Grid06 10 00, 06, 20 00, 09 91 00123.00Square Meter- 0
5.03Soffit and Exterior Closure System, PVC with wood support grid and Soffit Vents06 10 00, 06, 20 00, 09 91 0022.50Square Meter- 0
5.04Ceiling Trim, Interior, PVC06 10 00, 06, 20 00, 09 91 00108.00Meter- 0
5.06Masonry Vented WallDivision 042.20Square Meter- 0
Amdt25.07Clearstory Interior Enclosure System with CMU, Plastered and Painted to Match interior walls06 10 00, 06, 20 00, 09 91 009.00Square Meter- 0
Amdt25.08Concrete Counter 60 cm wide x92cm high, with Supports at 1020mm, Smooth Finish with 2 Coats of Sealer03 30 303.40Meter- 0
Sub-Total- 0
6.00Roofing, Gutters & Misc. Metals Sum
6.01Steel Roof Panels Sum with fasteners in place, Prepainted 26 gage, Purchase and delivery, warrantyDivisions 05, 07178.00Square Meter- 0
6.02Shaped Metal Flashing installed with anchors at maximum 40cm spacing, Galvanized, primed and painted with 2 coats of synthetic enamel, Development Length 500mmDivisions 05, 0725.80Meter- 0
Sub-Total- 0
7.00Doors & Windows
7.01Door, Steel, Double Sided, 800 x 2050mm D1 Installed with Fixtures, Primer plus 2 Coats of Oil-Based Paint05 50 00, Divisions 08, 093.00Pieces- 0
7.02Door, Wood, 800 x 2050mm D1 Installed with Fixtures, Primer plus 2 Coats of Paint05 50 00, Divisions 08, 098.00Pieces- 0
7.03Door Frame, Steel with Skylight F1, 900x2800mm Installed with Fixtures, Caulking, Primer plus 2 Coats of Oil Based Paint05 50 00, Divisions 08, 098.00Pieces- 0
7.04Door Frame, Steel F2 900 x 2100mm Installed with Fixtures, Caulking, Primer plus 2 Coats of Oil Based Paint05 50 00, Divisions 08, 091.00Pieces- 0
7.05Door Frame, Steel with Skylight and Security Bars, F3 900x2800mm Installed with Fixtures, Caulking, Primer plus 2 Coats of Oil Based Paint05 50 00, Divisions 08, 092.00Pieces- 0
7.07Window Steel, Installed, W2, 600 x 600mm with Caulking, Primed with 2 Coats of Oil-Based Paint05 50 00, Divisions 08, 094.00Pieces- 0
7.09Window Steel, Installed, W4, 600 x 725mm with Grill, Fixtures, Caulking, Primed with 2 Coats of Oil-Based Paint05 50 00, Divisions 08, 092.00Pieces- 0
7.12Window Double Steel, Installed, W7, 1200 x 1725mm with Grill, Fixtures, Caulking, Primed with 2 Coats of Oil-Based Paint05 50 00, Divisions 08, 0910.00Pieces- 0
7.13Window Double Steel, Installed, W8, 600 x 1325mm with Grill, Fixtures, Caulking, Primed with 2 Coats of Oil-Based Paint05 50 00, Divisions 08, 091.00Pieces- 0
Amdt27.26Window, Steel with Steel Frame, Installed S6, 1000 x 275mm, Insect Screen, primed with two Coats of synthetic enamel05 50 00, Divisions 08, 091.00Pieces- 0
Amdt27.27Louver, Steel with Steel Frame, Installed S7, 1000 x 275mm, Insect Screen, primed with two Coats of synthetic enamel05 50 00, Divisions 08, 091.00Pieces- 0
Amdt27.28Window/Louver, with Steel Frame, Installed S8, 2300 x 275mm, Insect Screen, primed with two Coats of Oil-Based Paint05 50 00, Divisions 08, 094.00Pieces- 0
7.29Glazing, 5 mm, Frosted/Opaque, Installed08 80 004.10Square Meter- 0
7.30Glazing, 5 mm, Clear, Installed08 80 0025.00Square Meter- 0
Sub-Total- 0
8.00Finishing
8.01Internal Wall Plastering, Two Coats Cement/Sand Mortar09 91 00321.00Square Meter- 0
8.02Internal Wall Surface, Final Coat Gypsum Plaster09 91 00321.00Square Meter- 0
8.05Plastic Emulsion Paint, Three Coats (Interior)09 91 00321.00Square Meter- 0
Sub-Total- 0
9.00SpecialtiesDiv 10, 12, 15
9.01Signage, Aluminum Placard with Vinyl Cover and Lettering1.00Pieces- 0
9.02Fire Extinguisher, 9 Kilogram Mounted with compatible bracket and "Fire Extinguisher" Signage.3.00Pieces- 0
9.07Metal Shelf, 35cm wide with mounting brackets21.00Meter- 0
9.08Grab Bars, Stainless Steel, 60cm length, installed1.00Pieces- 0
9.09Robe Hook, Installed1.00Pieces- 0
9.10Wooden Wardrobe with Doors, internal shelves and metal hanger rod, 220cm average wide by 210cm tall with two coats of polyurethane Varnish3.00Pieces- 0
9.11Masonry and Concrete Bench, 500mm x 800mm x 470mm high1.00Pieces- 0
Amdt29.12Outdoor Wash basin, Complete with1.00Pieces- 0
Sub-Total- 0
10.00Electrical Rough-In
Amdt210.01Secondary Distr. Board Flush Mtd, 24 space, lockable door with out circuit breakers, including (2 x 21mm) conduit to ceiling within masonry. Connect to Exterior Rated Meter Base w (2 x 35mm) conduit and terminate from Meter Base undergound to plug at 2 meters from face of building(2x35mm). Det 4 and 6/DE510Division 261.00Pieces- 0
10.02Conduit only with pull string for electric wire, Inside masonry, 21mm PVCDivision 26110.00Meter- 0
10.03Light Switch Box Only, Installed in Masonry with Blank CoverDivision 2612.00Pieces- 0
10.04Outlet Socket Box Only Installed in Masonry with Blank CoverDivision 2623.00Pieces- 0
10.05Wall mounted light Box Only Installed in Masonry with Blank CoverDivision 262.00Pieces- 0
10.06Interior Light Fixture Box Only Mounted in PVC Ceiling Panels with Blank CoverDivision 2616.00Pieces- 0
Sub-Total- 0
11.00Plumbing
11.02Handicap Toilet Fixture with Cover, Including Masonry PedestalDivision 221.00Pieces- 0
11.03Pit Vent, 100mm UPVCDivision 223.00Meter- 0
11.04Pit Vent CapDivision 221.00Meter- 0
11.06Sanitary Drainage Pipe, 100mm UPVCDivision 2210.00Meter- 0
11.08Sanitary Drainage Pipe, 50mm UPVCDivision 223.00Meter- 0
11.09Fittings, 50mm UPVC including, Bends and Sink Drain with PlugDivision 223.00Pieces- 0
11.10Concrete Gully BoxDivision 221.00Pieces- 0
Sub-Total- 0
SCHEDULE TOTAL- 0

Sch D Student PLs

Project:SEED RuralBILL OF QUANTITIESSCHEDULE D
Bid Date:______________________________________________________MALE AND FEMALE PIT LATRINES COMBINED1 EACH
Name of Bidder:______________________________________________________
Bid SectionBid ItemDescriptionSpecification SectionQuantityUnitUnit PriceExtensionSection Subtotal
1.00Concrete Work, Foundation
1.01Structural Excavation, includes 10% for over-excavation.31 20 00113.00Cubic Meter- 0
1.04Hard-Core under Exterior Slab31 20 0015.00Cubic Meter- 0
1.05Sand Blinding on Hard-Core Under Exterior Slab31 20 007.50Cubic Meter- 0
1.06Reinforced Concrete grade beams, suspended slab, pit footing, pit ringbeam, Class C-20/2503 30 3013.50Cubic Meter- 0
1.07Interior Floor Slab on Grade, Reinforced Concrete, Class C-20/2503 30 305.00Cubic Meter- 0
1.08Concrete formwork, Ground Contact03 30 3058.00Square Meter- 0
1.11Interior Floor Slab, Reinforcing Wire Mesh, A9803 30 3050.40Square Meter- 0
Amdt21.12Reinforcing Steel, grade beams, suspended slab, pit footing, pit ringbeam and pit masonry, Grade 45003 30 302,400.00Kilogram- 0
1.13Expansion Joint Material, Bitumen Impregnated, 12mm thickness03 30 306.00Square Meter- 0
1.14Structural Backfill, Select Material31 20 0085.00Cubic Meter- 0
1.15Hard-Core Drainage Material31 20 0016.00Cubic Meter- 0
Sub-Total- 0
2.00Concrete Work, Structure
2.01Reinforced Concrete in Columns, Class C-20/2503 30 30- 0Cubic Meter- 0
2.02Reinforced Concrete in Bond Beams on masonry, Class C-20/25 with exposed surfaces finished appropriate for location.03 30 301.60Cubic Meter- 0
2.03Concrete(steel or timber) formwork for Bond Beams on Masonry03 30 3099.00Square Meter- 0
2.04Reinforcing Steel in Bond Beams, Grade 45003 30 30423.00Kilogram- 0
Sub-Total- 0
3.00Masonry Work
3.01Hollow Core Concrete Block, Class AAA (5.0MPa), 200mm thickness including Open Joints where Indicated in PitDiv 4235.00Square Meter- 0
3.02Hollow Core Concrete Block, Class AAA (5.0MPa), 150mm thicknessDiv 439.00Square Meter- 0
3.03Mortar in Hollow Core BlockDiv 413.50Cubic Meter- 0
3.05Masonry Pointing, ExteriorDiv 4328.00Square Meter- 0
3.07Wall CopingDiv 446.00Meter- 0
Sub-Total- 0
4.00Roofing System
4.01Truss, Type 1 Welded, Bolted, Erected, Primer with 2-Coats of Oil-Based Paint- 0Pieces- 0
4.02Truss, Type 2 Welded, Bolted, Erected, Primer with 2-Coats of Oil-Based Paint- 0Pieces- 0
4.03Truss, Type 3 Welded, Bolted, Erected, Primer with 2-Coats of Oil-Based Paint- 0Pieces- 0
4.04Rafter R1, Welded and Erected, Primer with 2-Coats of Oil-Based Paint- 0Pieces- 0
4.05Purlins Cold Formed with Connection Angle , Bolts and Erected, 120 x 60 x 2.5mm- 0M- 0
4.06Purlins Cold Formed with Connection Angle , Bolts and Erected, 75x50 x20x2.0mm- 0M- 0
4.07Fascia Bracing, Welded, Painted and Erected- 0Kilogram- 0
4.08Misc. Steel for Bracing and Supports, Painted and Erected- 0Kilogram- 0
4.09Teacher Housing Roofing System, Complete with all Structural Sections, Connections, Welding, Erection. Primed and Painted with 2 Coats of Oil-Based Paint, Less Purlins and Anchor Bolts- 0Kilogram- 0
4.10Student Male and Female Pit Latrine Roofing System: Wood Truss, Complete with all Structural Sections, Connections. Primed and Painted with 2 Coats of Oil-Based Paint, Including Purlins and Anchor Straps. Price per BuildingDivision 62.00Pieces- 0
Sub-Total- 0
5.00Carpentry and Joinery
5.01Wood Fascia and Soffit Board w Prime Coat and 2 Coats Synthetic Enamel Paint all Sides, 20 CM Tall06 10 00, 06, 20 00, 09 91 0076.00Meter- 0
5.06Masonry Vented WallDivision 410.00Square Meter- 0
Sub-Total- 0
6.00Roofing, Gutters & Misc. Metals Sum
6.01Steel Roof Panels Sum with fasteners in place, Prepainted 26 gage, Purchase and delivery, warrantyDivisions 05, 0743.00Square Meter- 0
6.02Shaped Metal Flashing installed with anchors at maximum 40cm spacing, Galvanized, primed and painted with 2 coats of synthetic enamel, Development Length 500mmDivisions 05, 07- 0Meter- 0
6.03Roof Gutter, 150mm UPVCDivisions 05, 07- 0Meter- 0
6.04PVC Roof Gutter Downspouts, 100mm UPVCDivisions 05, 07- 0Meter- 0
Sub-Total- 0
7.00Doors & Windows
7.01Door, Steel 800 x 2050mm D1 Installed with Fixtures, Primer plus 2 Coats of Oil-Based Paint05 50 00, Divisions 08, 099.00Pieces- 0
7.04Door Frame, Steel F2 900 x 2100mm Installed with Fixtures, Caulking, Primer plus 2 Coats of Oil Based Paint05 50 00, Divisions 08, 099.00Pieces- 0
7.31Security Gate, Steel D2 900 x 2150-2300mm Installed with Fixtures, Caulking, Primer plus 2 Coats of Oil Based Paint05 50 00, Divisions 08, 094.00Pieces- 0
7.32Security Gate Frame, Steel F4 1600 x 2300mm Installed with Fixtures, Caulking, Primer plus 2 Coats of Oil Based Paint05 50 00, Divisions 08, 092.00Pieces- 0
7.33Security Gate Frame, Steel F5 1200 x 2150mm Installed with Fixtures, Caulking, Primer plus 2 Coats of Oil Based Paint05 50 00, Divisions 08, 092.00Pieces- 0
Sub-Total- 0
8.00Finishing
8.01Internal Wall Plastering, Two Coats Cement/Sand Mortar09 91 00190.00Square Meter- 0
8.04Floor Mortar Screed, Smooth with 2 Coats Plaster, 48mm Thick, Internal only09 91 0055.00Square Meter- 0
8.05Plastic EmuLump Emulsion Paint, Three Coats (Interior)09 91 0088.00Square Meter- 0
8.06Two Coats Epoxy Paint in Stall and Urinal up to 1500mm above floor09 91 00100.00Square Meter- 0
Sub-Total- 0
9.00Specialties
9.01Signage, Aluminum Placard with Vinyl Cover and Lettering10 14 264.00Pieces- 0
9.02Fire Extinguisher, 9 Kilogram Mounted with compatible bracket and "Fire Extinguisher" Signage.10 44 002.00Pieces- 0
9.03Steel Handrail, Installed, Primed and Painted with 2-Coats of Synthetic Enamel paint05 50 004.00Meter- 0
9.04Concrete Steps03 30 000.80Cubic Meter- 0
9.05Specialty Concrete for Tanks and Troughs, Water Tight, Smooth-Troweled Finish with 3 Coats of Concrete Plaster31 20 003.60Cubic Meter- 0
9.06Water Basin Cover, 2.0mm Steel, Primed and Painted with 2 Coats of Synthetic Enamel Paint05 50 002.00Pieces- 0
9.07Stainless Steel Grab BarsDivision 223.00Pieces- 0
9.08Robe Hook, InstalledDivision 221.00Pieces- 0
Sub-Total- 0
11.00Plumbing
10.01Squat Toilet Fixture with CoverDivision 226.00Pieces- 0
10.02Handicap Toilet Fixture with Cover, Including Masonry PedestalDivision 222.00Pieces- 0
10.03Pit Vent, 100mm UPVCDivision 2216.00Meter- 0
10.04Pit Vent CapDivision 224.00Meter- 0
10.05Handwash SpigotDivision 226.00Pieces- 0
10.06Sanitary Drainage Pipe, 100mm UPVCDivision 2210.00Meter- 0
10.07Fittings, 90 Degree 100mm UPVCDivision 222.00Pieces- 0
10.08Sanitary Drainage Pipe, 50mm UPVCDivision 2210.00Meter- 0
10.09Fittings, 50mm UPVC including, Bends and Sink Drain with PlugDivision 226.00Pieces- 0
10.10Concrete Gully BoxDivision 222.00Pieces- 0
Sub-Total- 0
SCHEDULE TOTAL- 0

Sch E Teacher PL

Project:SEED RuralBILL OF QUANTITIESSCHEDULE E
Bid Date:______________________________________________________TEACHER PIT LATRINE1 Each
Name of Bidder:______________________________________________________
Bid SectionBid ItemDescriptionSpecification SectionQuantityUnitUnit PriceExtensionSection Subtotal
1.00Concrete Work, Foundation
1.01Structural Excavation, includes 10% for over-excavation.31 20 0081.00Cubic Meter- 0
1.04Hard-Core under Exterior Slab31 20 004.00Cubic Meter- 0
1.05Sand Blinding on Hard-Core Under Exterior Slab31 20 002.00Cubic Meter- 0
1.06Reinforced Concrete grade beams, suspended slab, pit footing, pit ringbeam, Class C-20/2503 30 305.80Cubic Meter- 0
1.07Interior Floor Slab on Grade, Reinforced Concrete, Class C-20/2503 30 301.40Cubic Meter- 0
1.08Concrete formwork, Ground Contact03 30 3022.50Square Meter- 0
1.11Interior Floor Slab, Reinforcing Wire Mesh, A9803 30 3013.50Square Meter- 0
Amdt21.12Reinforcing Steel, grade beams, suspended slab, pit footing, pit ringbeam and pit masonry, Grade 45003 30 30680.00Kilogram- 0
1.13Expansion Joint Material, Bitumen Impregnated, 12mm thickness03 30 305.20Square Meter- 0
1.14Structural Backfill, Select Material31 20 0026.50Cubic Meter- 0
1.15Hard-Core Drainage Material31 20 006.80Cubic Meter- 0
Sub-Total- 0
2.00Concrete Work, Structure
2.01Reinforced Concrete in Columns, Class C-20/2503 30 30- 0Cubic Meter- 0
2.02Reinforced Concrete in Bond Beams on masonry, Class C-20/25 with exposed surfaces finished appropriate for location.03 30 300.70Cubic Meter- 0
2.03Concrete(steel or timber) formwork for Bond Beams and suspended slab and beams03 30 308.40Square Meter- 0
2.04Reinforcing Steel in Bond Beams, Grade 450150.00Kilogram- 0
Sub-Total- 0
3.00Masonry Work
3.01Hollow Core Concrete Block, Class AAA (5.0MPa), 200mm thickness including Open Joints where Indicated in PitDiv 4136.00Square Meter- 0
3.02Hollow Core Concrete Block, Class AAA (5.0MPa), 150mm thicknessDiv 4- 0Square Meter- 0
3.03Mortar in Hollow Core BlockDiv 44.50Cubic Meter- 0
3.05Masonry Pointing, ExteriorDiv 458.00Square Meter- 0
Sub-Total- 0
4.00Roofing System
4.01Truss, Type 1 Welded, Bolted, Erected, Primer with 2-Coats of Synthetic Enamel Paint- 0Pieces- 0
4.02Truss, Type 2 Welded, Bolted, Erected, Primer with 2-Coats of Synthetic Enamel Paint- 0Pieces- 0
4.03Truss, Type 3 Welded, Bolted, Erected, Primer with 2-Coats of Synthetic Enamel Paint- 0Pieces- 0
4.04Rafter R1, Welded and Erected, Primer with 2-Coats of Synthetic Enamel Paint- 0Pieces- 0
4.05Purlins Cold Formed with Connection Angle , Bolts and Erected, 120 x 60 x 2.5mm- 0M- 0
4.06Purlins Cold Formed with Connection Angle , Bolts and Erected, 75x50 x20x2.0mm- 0M- 0
4.07Fascia Bracing, Welded, Painted and Erected- 0Kilogram- 0
4.08Misc. Steel for Bracing and Supports, Painted and Erected- 0Kilogram- 0
4.09Teacher Housing Roofing System, Complete with all Structural Sections, Connections, Welding, Erection. Primed and Painted with 2 Coats of Synthetic Enamel Paint, Less Purlins and Anchor Bolts- 0Kilogram- 0
4.10Teacher Pit Latrine Roofing System: Wood Truss, Complete with all Structural Sections, Connections. Primed and Painted with 2 Coats of Synthetic Enamel Paint, Including Purlins and Anchor Straps. Price per BuildingDivision 61.00Pieces- 0
Sub-Total- 0
5.00Carpentry and Joinery
5.01Wood Fascia and Soffit Board w Prime Coat and 2 Coats Synthetic Enamel Paint all Sides, 20 CM Tall06 10 00, 06, 20 00, 09 91 0023.00Meter- 0
5.06Masonry Vented WallDivision 43.20Square Meter- 0
Sub-Total- 0
6.00Roofing, Gutters & Misc. Metals Sum
6.01Steel Roof Panels Sum with fasteners in place, Prepainted 26 gage, Purchase and delivery, warrantyDivisions 05, 0732.00Square Meter- 0
6.02Shaped Metal Flashing installed with anchors at maximum 40cm spacing, Galvanized, primed and painted with 2 coats of synthetic enamel, Development Length 500mmDivisions 05, 07- 0Meter- 0
6.03Roof Gutter, 150mm UPVCDivisions 05, 07- 0Meter- 0
6.04PVC Roof Gutter Downspouts, 100mm UPVCDivisions 05, 07- 0Meter- 0
Sub-Total- 0
7.00Doors & Windows
7.01Door, Steel 800 x 2050mm D1 Installed with Fixtures, Primer plus 2 Coats of Oil-Based Paint05 50 00, Divisions 08, 094.00Pieces- 0
7.04Door Frame, Steel F2 900 x 2100mm Installed with Fixtures, Caulking, Primer plus 2 Coats of Oil Based Paint05 50 00, Divisions 08, 094.00Pieces- 0
7.31Security Gate, Steel D2 900 x 2150-2300mm Installed with Fixtures, Caulking, Primer plus 2 Coats of Oil Based Paint05 50 00, Divisions 08, 09- 0Pieces- 0
7.32Security Gate Frame, Steel F4 1600 x 2300mm Installed with Fixtures, Caulking, Primer plus 2 Coats of Oil Based Paint05 50 00, Divisions 08, 09- 0Pieces- 0
7.33Security Gate Frame, Steel F5 1200 x 2150mm Installed with Fixtures, Caulking, Primer plus 2 Coats of Oil Based Paint05 50 00, Divisions 08, 09- 0Pieces- 0
Sub-Total- 0
8.00Finishing
8.01Internal Wall Plastering, Two Coats Cement/Sand Mortar09 91 0098.00Square Meter- 0
8.04Floor Mortar Screed, Smooth with 2 Coats Plaster, 48mm Thick, Internal only09 91 0026.00Square Meter- 0
8.05Plastic Emulsion Paint, Three Coats (Interior)09 91 0046.00Square Meter- 0
8.06Two Coats Epoxy Paint in Stall and Urinal up to 1500mm above floor09 91 0052.00Square Meter- 0
Sub-Total- 0
9.00Specialties
9.01Signage, Aluminum Placard with Vinyl Cover and Lettering10 14 262.00Pieces- 0
9.02Fire Extinguisher, 9 Kilogram Mounted with compatible bracket and "Fire Extinguisher" Signage.10 44 001.00Pieces- 0
9.03Steel Handrail, Installed, Primed and Painted with 2-Coats of Synthetic Enamel paint05 50 002.00Meter- 0
9.04Concrete Steps03 30 000.40Cubic Meter- 0
9.05Specialty Concrete for Tanks and Troughs, Water Tight, Smooth-Troweled Finish with 3 Coats of Concrete Plaster03 30 301.50Cubic Meter- 0
9.06Water Basin Cover, 2.0mm Steel, Primed and Painted with 2 Coats of Synthetic Enamel Paint05 50 001.00Pieces- 0
9.07Stainless Steel Grab BarsDivision 223.00Pieces- 0
9.08Robe Hook, Installed1.00Pieces- 0
Sub-Total- 0
11.00Plumbing
11.01Squat Toilet Fixture with CoverDivision 22- 0Pieces- 0
10.01Handicap Toilet Fixture with Cover, Including Masonry PedestalDivision 222.00Pieces- 0
10.02Pit Vent, 100mm UPVCDivision 228.00Meter- 0
10.03Pit Vent CapDivision 222.00Meter- 0
10.04Handwash SpigotDivision 223.00Pieces- 0
10.05Sanitary Drainage Pipe, 100mm UPVCDivision 224.00Meter- 0
10.06Fittings, 90 Degree 100mm UPVCDivision 221.00Pieces- 0
10.07Sanitary Drainage Pipe, 50mm UPVCDivision 225.00Meter- 0
10.08Fittings, 50mm UPVC including, Bends and Sink Drain with PlugDivision 224.00Pieces- 0
10.09Concrete Gully BoxDivision 221.00Pieces- 0
Sub-Total- 0
SCHEDLE TOTAL- 0

Sch F20

Project:SEED RuralBILL OF QUANTITIESSCHEDULE F20
Bid Date:______________________________________________________MOBILIZATION AND SITE DEVELOPMENTLulanga
Name of Bidder:______________________________________________________
Bid SectionBid ItemDescriptionSpecification SectionQuantityUnitUnit PriceExtensionSection Subtotal
Mobilization
1.00Mobilization
1.01Mobilization to the site for Facility and Site Construction and including all requirements of the Contract Documents and Specifications Division 1Division 011.00Lump Sum- 0
Sub-Total- 0
Site Work
2.00Site Clearing and Grading
2.01Tree Clearing and Site Grubbing, disposal of off-site with no burning allowed02 41 16; 31 10 001.00Lump Sum- 0
2.02Tree Seedling Planting to Replace Cleared Trees32 93 00- 0Pieces- 0
2.03Topsoil Stripping and wasted on-site as embankment slopes or berms where directed by USAID.31 20 001,770.00Cubic Meter- 0
2.04Mass Excavation and placement as compacted embankment or suitably wasted on-site.31 20 00; 31 31 16; 31 50 0030.00Cubic Meter- 0
2.05Off-Site Select Material Borrow31 20 003,440.00Cubic Meter- 0
2.06Building Pad Preparation31 20 001,100.00Square Meter- 0
2.07Site finish grading including earth driveways, earth walkways, swales and final surface shaping for drainage31 20 008,900.00Square Meter- 0
Amdt12.08Gravel parking pad, 100mm crushed gravel, compacted and graded to drain33 41 00160.00Square Meter- 0
Sub-Total- 0
3.00Concrete
3.01Concrete paved site sidewalks, variable width, 100mm thickness, 20/25MPA concrete, width as detailed on the site drawings32 13 13263.00Square Meter- 0
3.02Concrete Steps with Reinforcing steel03 30 00Cubic Meter- 0
3.03Hand-Rail05 50 00Meter- 0
Sub-Total- 0
4.00Site Drainage
4.01Drainage Piping, 30cm PVC, Schedule 4033 41 002.00Meter- 0

This is the start of the file's text. The full file is on GovTribe.