USCG_Seattle_Bldg_1_Major_MR_Exterior_Survey-Final_Reference_Doc....pdf
PDF 4 MB Posted
- Solicitation number
- 70Z08818BPQQ11500
About this file
USCG Seattle Bldg 1 Major MR Exterior Survey-Final_Reference_Doc.
View the file
Other files
Show all 22
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Asbestos, Lead Based Paint and PCB Survey Report
Major M&R Building 1 Exterior
USCG-Base Seattle, Building 1
1519 Alaskan Way South
Seattle, King County, Washington March 7, 2014
Terracon Project No. 81147014
Prepared for:
United States Coast Guard
CEU Oakland
Prepared by:
Terracon Consultants, Inc.
Mountlake Terrace, Washington As a Subcontractor to EnviroApplications, Inc.
San Diego, California
KMLee1 Text Box
REFERENCE DOCUMENT
TABLE OF CONTENTS
1.0 INTRODUCTION
1.1 Project Objective
2.0 BUILDING DESCRIPTION
3.0 ASBESTOS FIELD ACTIVITIES
3.1 Visual Assessment
3.2 Physical Assessment
3.3 Sample Collection
3.4 Sample Analysis
4.0 ASBESTOS REGULATORY OVERVIEW
5.0 LEAD BASED PAINT FIELD ACTIVITIES
6.0 LEAD BASED PAINT REGULATORY OVERVIEW
7.0 PCB CONTAINING PAINT FIELD ACTIVITIES
8.0 PCB CONTAINING PAINT REGULATORY OVERVIEW
9.0 FINDINGS AND RECOMMENDATIONS
10.0 GENERAL COMMENTS
APPENDICES
APPENDIX A – ASBESTOS SURVEY SAMPLE SUMMARY
APPENDIX B – LEAD BASED PAINT SAMPLE SUMMARY
APPENDIX C – PCB PAINT SAMPLE SUMMARY
APPENDIX D – CHAIN OF CUSTODY AND LABORATORY ANALYTICAL REPORTS
APPENDIX E – SAMPLE LOCATION PLAN:
FIGURE 1-3 – ASBESTOS, LEAD AND PCB SAMPLE LOCATIONS
APPENDIX F – TRAINING CERTIFICATES
Responsive ■ Resourceful ■ Reliable 1
ASBESTOS, LEAD BASED PAINT AND PCB SURVEY REPORT
Major M&R Building 1 Exterior USCG-Base Seattle, Building 1
1519 Alaskan Way South Seattle, King County, Washington
Terracon Project No. 81147014
March 7, 2014
1.0 INTRODUCTION
Terracon conducted an asbestos, lead-based paint and polychlorinated biphenyls (PCB) containing paint survey of the interior and exterior materials at window installations, exterior surfaces, select roof portions and the south entrance of the United States Coast Guard (USCG) - Base Seattle, Building 1, located at 1519 Alaskan Way South in Seattle, King County, Washington. The survey was conducted on February 18 and March 4, 2014, by an Asbestos Hazard Emergency Response Act (AHERA)-accredited asbestos inspector in general accordance with the Master Subcontract Agreement (MSA) dated August 9, 2013, and the email authorization dated February 11, 2014, between Terracon and EnviroApplications, Inc. (EAI) authorizing Terracon to perform this service. Interior and exterior building components were surveyed and homogeneous areas of suspect asbestos-containing materials (ACM), suspect lead-based paints (LBP) and suspect PCB containing paints were visually identified and documented.
Although reasonable effort was made to survey inaccessible suspect materials, additional suspect but unsampled ACM, LBP and PCB containing paint could be located in walls, in voids or in other concealed areas. Suspect ACM samples were collected in general accordance with the sampling protocols outlined in United States Environmental Protection Agency (EPA) 40 Code of Federal Regulations (CFR) 763.86. Samples were delivered to accredited laboratories for analysis by polarized light microscopy (PLM) for asbestos samples, flame atomic absorption spectrometry (FAAS) for LBP samples and Environmental Protection Agency (EPA) Method 8082 (gas chromatography) for PCB samples.
1.1 Project Objective
We understand this asbestos, lead-based paint, and PCB containing paint survey was requested due to the planned replacement of the buildings windows, select roof portions and south entrance doorway. It should be noted that adverse weather conditions did not allow for sampling/patching of roof portions outside of the north portion of the 2nd floor balcony/emergency exit walkway area.
Asbestos, Lead Based Paint and PCB Survey Report USCG-Base Seattle, Bldg. 1 ■ Seattle, Washington March 7, 2014 ■ Terracon Project No. 81147014
Responsive ■ Resourceful ■ Reliable 2
EPA regulation 40 CFR 61, Subpart M, National Emission Standards for Hazardous Air Pollutants (NESHAP), prohibits the release of asbestos fibers to the atmosphere during renovation or demolition activities. The asbestos NESHAP requires that potentially regulated asbestos-containing building materials be identified, classified and quantified prior to planned renovation activities. The NESHAP authority for King County is the Puget Sound Clean Air Agency
(PSCAA).
The Department of Labor and Industries (L&I) enforces the Washington Industrial Safety and Health (WISHA) Standard for Lead in Construction, Washington Administrative Code (WAC) 296- 155-176, which defines the lead exposure limits for all construction workers performing demolition and/or renovation activities. Should lead be detected at any concentration, WAC 296-155-176 provides the appropriate methods of compliance to ensure worker safety from potential lead exposure.
The State of Washington Hazardous Waste and Toxics Reduction (HWTR) Program affects persons who generate, transport, transfer, recycle, treat, store, or dispose of regulated dangerous wastes, as defined in the Dangerous Waste Regulations (173-303 WAC). Solid wastes, including demolition/renovation debris, must be evaluated to determine if the waste designates as lead-containing dangerous waste prior to disposal.
The Toxic Substances Control Act (TSCA) of 1976 addresses the production, importation, use, and disposal of specific chemicals, including PCBs. Part 761 of the TSCA rule establishes prohibitions of, and requirements for, the manufacture, processing, distribution in commerce, use, disposal, storage, and marking of PCBs and PCB items. Part 761.20 prohibits the use of any PCB, or any PCB item, regardless of concentration, other than in a totally enclosed manner.
2.0 BUILDING DESCRIPTION
The site is developed with a 5-story structure (not including the basement) comprised of cast-in-place concrete exterior and central core (stairwell/elevator shaft) walls. Interior corridor and partition walls are primarily gypsum block with wood-framed partition walls in some areas.
Interior vertical finishes observed on perimeter walls consisted primarily of plaster with areas of gypsum wall board (4th floor southeast window „deletes‟) and glass. Exterior vertical finishes consisted of plaster, glass and exterior insulating foam system (EIFS) apparently installed over the structures original plaster in many areas. Exterior horizontal finishes consisted primarily of concrete, plaster, wood and single-ply rubber membrane roofing applied over historical membrane and asphalt roof systems (2nd floor balcony/emergency exit walkway).
http://www.epa.gov/waste/hazard/tsd/pcbs/index.htm
Responsive ■ Resourceful ■ Reliable 3
3.0 ASBESTOS FIELD ACTIVITIES
The survey was conducted by AHERA-accredited asbestos inspector Adam Stauffer. A copy of Mr. Stauffer’s asbestos inspector training certificate is attached as Appendix F. The survey was conducted in general accordance with the sample collection protocols established in EPA regulation 40 CFR 763, the Asbestos Hazard Emergency Response Act (AHERA). A summary of survey activities is provided below.
3.1 Visual Assessment
Survey activities began with visual observation of the interior and exterior of the areas that will potentially be disturbed during renovation activities in order to locate and identify homogeneous areas of suspect ACM. A homogeneous area (HA) consists of building materials that appear similar throughout in terms of color and texture. The assessment was conducted throughout visually accessible areas of the exterior walls, interior walls at window installations, select roof areas, and south entrance doorway building components.
Building materials identified as concrete, glass, wood, masonry, metal or rubber were not considered suspect ACM.
3.2 Physical Assessment
A physical assessment of each homogeneous area of suspect ACM was conducted to assess the friability and condition of the materials. A friable material is defined by the EPA as a material which can be crumbled, pulverized or reduced to powder by hand pressure when dry. Friability was assessed by physically touching suspect materials.
3.3 Sample Collection
Based on results of the visual observation, bulk samples of suspect ACM were collected in general accordance with AHERA sampling protocols. Random samples of suspect materials were collected in each homogeneous area. The inspector collected bulk samples using wet methods, as applicable, to reduce the potential for fiber release. Samples were placed in sealable containers and labeled with unique sample numbers using an indelible marker.
Terracon collected 35 bulk samples from 9 homogeneous areas of suspect ACM. A summary of all samples collected is included as Appendix A.
Responsive ■ Resourceful ■ Reliable 4
3.4 Sample Analysis
Bulk ACM samples were submitted under chain of custody to Seattle Asbestos Test (SAT) of Lynnwood, Washington for analysis by polarized light microscopy (PLM) with dispersion staining techniques per EPA methodology (600/R-93/116). The percentage of asbestos, where applicable, was determined by microscopic visual estimation.
SAT is accredited under the National Voluntary Laboratory Accreditation Program (NVLAP Accreditation No. 200768-0).
4.0 ASBESTOS REGULATORY OVERVIEW
The NESHAP regulation for asbestos regulates asbestos fiber emissions and asbestos waste disposal practices. It requires the identification of existing asbestos-containing materials (ACM) according to friability prior to demolition or renovation activity. Friable ACM is a material containing more than 1% asbestos that, when dry, may be crumbled, pulverized or reduced to powder by hand pressure.
The NESHAP regulation classifies ACM as either regulated asbestos-containing material (RACM), Category I non-friable ACM or Category II non-friable ACM. RACM includes all friable ACM, along with Category I non-friable ACM that has become friable or will be or has been subjected to sanding, grinding, cutting or abrading, and Category II non-friable ACM that has a high probability of becoming or has become crumbled, pulverized, or reduced to powder in the course of renovation or demolition activity. Category I non-friable ACMs are exclusively asbestos-containing packings, gaskets, resilient floor coverings, floor covering mastics and asphalt roofing products that contain more than 1% asbestos. Category II non-friable ACM are all other non-friable materials other than Category I non-friable ACM that contain more than 1% asbestos. RACM must be removed prior to renovation or demolition activities.
Washington Administrative Code (WAC) 173 400 075 adopts the federal NESHAP rule by reference. In the State of Washington, authority to administer NESHAP requirements is delegated to the regional air pollution authorities (e.g., the local Clean Air Agency or the Washington State Department of Ecology). In King County, the NESHAP requirements are administered by the Puget Sound Clean Air Authority (PSCAA). PSCAA must be notified at least 10 working days prior to the demolition of any structure with a projected roof area greater than 120 square feet, regardless of whether any asbestos was identified. Notification is not required for renovation projects, unless the project involves the disturbance of friable asbestos containing materials. The owner or operator must also provide the Washington State Department of Labor and Industry (L&I) with written notification at least 10 working days prior to the commencement of asbestos
Responsive ■ Resourceful ■ Reliable 5 removal projects involving at least 10 linear feet or 48 square feet of RACM. Removal of RACM must be conducted by a State of Washington-certified asbestos abatement contractor.
In the State of Washington, worker exposures to asbestos are governed by L&I‟s Division of Occupational Safety and Health (DOSH). The administrative rule WAC 296-62-07705 requires that employee exposure to airborne asbestos fibers be maintained below 0.1 asbestos fibers per cubic centimeter of air (0.1 f/cc) as an eight hour time weighted average. State of Washington Occupational Safety and Health rules also classify construction and maintenance activities which could disturb ACM, and specify work practices and precautions which employers must follow when their employees engage in each class of regulated work.
5.0 LEAD BASED PAINT FIELD ACTIVITIES
In conjunction with the asbestos survey, Terracon personnel visually assessed interior and exterior areas of the site structure slated for renovation, and performed limited LBP sampling that consisted of collecting eight (8) paint chip samples from various painted components. All lead samples were submitted under chain of custody to EMSL Analytical, Inc. (EMSL), of Cinnaminson, New Jersey. The LBP samples were analyzed by flame atomic absorption spectrometry per EPA Method 7000B. EMSL is accredited under the Environmental Lead Laboratory Accreditation Program (ELLAP No. 100194).
6.0 LEAD BASED PAINT REGULATORY OVERVIEW
Lead is regulated by the EPA, the Washington State Department of Ecology (Ecology), the United States Occupation Safety and Health Administration (OSHA) and WISHA (enforced by L&I). The EPA regulates lead use, while both the EPA and Ecology regulate removal, and disposal. OSHA and WISHA both regulate lead exposure to workers. The EPA defines LBP as paint, varnish, stain, or other applied coating that contains lead equal to or greater than 1.0 mg/cm2, 5,000 mg/kg, or 0.5% by dry weight as determined by laboratory analysis. For the purpose of the OSHA lead standard, lead includes metallic lead, all inorganic lead compounds, and organic lead soaps. A synopsis of the OSHA regulations (29 CFR 1926.62) and the applicability are as follows:
The OSHA Interim Lead Standard for Construction (29 CFR 1926.62) applies to all construction work where an employee may be occupationally exposed to lead. All work related to construction, alteration, or repair (including painting and decorating) is included. The lead-in-construction standard applies to any detectable concentration of
Responsive ■ Resourceful ■ Reliable 6 lead in paint, as even small concentrations of lead can result in unacceptable employee exposures depending upon on the method of removal and other workplace conditions.
Similar to the OSHA standard, the WISHA Standard for Lead in Construction, states that if lead is present in the workplace in any quantity WISHA requires that demolition activities be conducted in accordance with WAC 296-155-176, lead Safety Standards for Construction
Work.
In accordance with Ecology‟s Dangerous Waste Regulations, solid wastes must be designated to see if they are dangerous wastes before disposal unless they are exempted or removed from the dangerous waste regulations. If any of the samples are reported with leachable lead concentration of 5.0 mg/L or more, then the waste must be classified and disposed of as dangerous waste.
7.0 PCB CONTAINING PAINT FIELD ACTIVITIES
In conjunction with the asbestos survey, Terracon personnel visually assessed the exterior insulation and finishing system (EIFS) paint on the site structure slated for renovation, and performed limited PCB sampling that consisted of collecting three (3) paint chip samples from various painted EIFS components. All PCB samples were submitted under chain of custody to NVL Labs Inc. (NVL), of Seattle, Washington. The PCB samples were analyzed by gas chromatography per EPA Method 8082. NVL is accredited under the Washington State Department of Ecology Environmental Laboratory Accreditation Program (No. C797).
8.0 PCB CONTAINING PAINT REGULATORY OVERVIEW
The Toxic Substances Control Act (TSCA) of 1976 addresses the production, importation, use, and disposal of specific chemicals, including PCBs. Part 761 of the TSCA rule establishes prohibitions of, and requirements for, the manufacture, processing, distribution in commerce, use, disposal, storage, and marking of PCBs and PCB items. Part 761.20 prohibits the use of any PCB, or any PCB item, regardless of concentration, other than in a totally enclosed manner.
For the most part, EPA regulates the storage and disposal of PCB wastes under TSCA section 6(e)(1) authority, rather than under the Resource Conservation and Recovery Act (RCRA), unless the PCB waste also meets the definition of RCRA hazardous waste. However, to better manage PCB waste, EPA has promulgated requirements for a tracking system that is similar to the “cradle-to-grave” tracking system for hazardous wastes under the RCRA Subtitle C Program.
http://www.epa.gov/waste/hazard/tsd/pcbs/index.htm
Responsive ■ Resourceful ■ Reliable 7
Some PCB materials are classified as “PCB bulk product waste” for the purposes of disposal.
PCB bulk product waste is waste derived from manufactured products containing PCBs in a non-liquid state, at any concentration where the concentration at the time of designation for disposal was greater than or equal to 50 ppm PCBs. PCB bulk product waste includes paint.
The significance of the PCB bulk product waste designation is that many of the rules that apply to other types of PCB wastes do not apply to PCB bulk product waste.
9.0 FINDINGS AND RECOMMENDATIONS
Asbestos
Laboratory analysis did not identify asbestos in any of the 35 samples submitted.
Appendix A identifies the homogeneous areas sampled, sample identification numbers, material descriptions, and analytical results. Laboratory analytical reports and chains of custody are included in Appendix D. In addition Appendix E contains the sample location plans: Figures 1-3
– Asbestos, Lead and PCB Sample Locations.
In the event that unsampled suspect ACM is discovered during renovation/demolition activities, Terracon recommends that the renovation contractor contact EAI and Terracon immediately upon discovery, so that samples of the suspect ACM can be collected and analyzed in order to classify, and/or quantify the material.
Lead
Based on a review of the analytical results, three (3) of the eight (8) sampled components were found to contain lead that exceeded 5,000 mg/kg (equivalent to 5,000 parts-per-million or 0.5% by weight), which is the maximum concentration to be considered non-LBP as defined by the
EPA.
Cream-beige over tan, orange, lt. green (and other colors) 2nd floor exterior balcony/ramp handrail
Light blue-grey 2nd floor balcony/ramp „shed‟ roof rafters Cream-beige over tan, orange (and other colors 5th floor façade balcony railing
Four (4) additional components, of the eight (8) sampled, were found to be lead-containing, however, concentrations were below 5,000 mg/kg, the maximum concentration to be considered non-LBP as defined by the EPA.
Responsive ■ Resourceful ■ Reliable 8
Appendix B identifies the color sampled, substrate, building component, sample identification numbers, location, condition, and analytical results. Laboratory analytical reports and chains of custody are included in Appendix D. In addition Appendix E contains the sample location plans:
Figures 1-3 – Asbestos, Lead and PCB Sample Locations.
This LBP survey was limited to readily observable and accessible surfaces. Terracon cannot guarantee all other building components (besides those noted above) to be LBP free as the possibility exists that LBP coated surfaces may be hidden from sight or in inaccessible locations, or the homogeneous construction areas identified may not be truly homogeneous.
This limited LBP survey was not performed to the United States Department of Housing and Urban Development‟s (HUD) Guidelines for the Evaluation and Control of Lead-Based Paint
Hazards in Housing standards. It should be understood that this LBP survey is not considered to be comprehensive in nature, and the results are not intended to be used to determine lead hazards, develop abatement plans, or prepare detailed cost estimates for abatement.
According to the L&I, abatement of LBP is not required prior to demolition. However, Terracon recommends that the results of this sampling be provided to your renovation contractor, who should subsequently be responsible for determining lead hazards.
In accordance with Ecology‟s Dangerous Waste Regulations, solid wastes must be designated to see if they are dangerous wastes before disposal unless they are exempted or removed from the dangerous waste regulations. Therefore Terracon recommends that representative samples of the building renovation/demolition waste stream be tested through laboratory analyses in order to determine if the waste is hazardous. Specifically, toxicity characteristics leaching procedure (TCLP) sampling should be performed and samples analyzed for leachable lead. If the samples are reported with a leachable lead concentration of 5.0 mg/L or more, then the waste must be classified and disposed of as hazardous waste.
PCBs
Based on a review of the analytical results, none of the three (3) sampled components were found to contain detectable levels of PCBs.
Appendix C identifies the color sampled, substrate, building component, sample identification numbers, location, condition, and analytical results. Laboratory analytical reports and chains of custody are included in Appendix D. In addition Appendix E contains the sample location plans:
Figures 1-3 – Asbestos, Lead and PCB Sample Locations.
Responsive ■ Resourceful ■ Reliable 9
This PCB survey was limited to readily observable and accessible exterior EIFS surfaces per the client‟s request. It should be understood that this PCB survey is not considered to be comprehensive in nature, and the results are not intended to be used to determine PCB hazards, develop abatement plans, or prepare detailed cost estimates for abatement.
10.0 GENERAL COMMENTS
This asbestos, lead-based paint and PCB containing paint survey was conducted in a manner consistent with the level of care and skill ordinarily exercised by members of the profession currently practicing under similar conditions in the same locale. The results, findings, conclusions and recommendations expressed in this report are based on conditions observed during our survey of the building. The information contained in this report is relevant to the date on which this survey was performed, and should not be relied upon to represent conditions at a later date.
This report has been prepared on behalf of and exclusively for use by the United States Coast Guard and EAI for specific application to their project as discussed. This report is not a bidding document. Contractors or consultants reviewing this report must draw their own conclusions regarding further investigation or remediation deemed necessary. Terracon does not warrant the work of regulatory agencies, laboratories or other third parties supplying information which may have been used in the preparation of this report. No warranty, express or implied is made.
APPENDIX A
ASBESTOS SURVEY SAMPLE SUMMARY
MAJOR M&R BUILDING 1 EXTERIOR
USCG-BASE SEATTLE, BUILDING 1
1519 ALASKAN WAY SOUTH
SEATTLE, KING COUNTY, WASHINGTON
HOMOGENEOUS
AREA
SAMPLE NO. DESCRIPTION SAMPLE LOCATION
1-1 White adhesive on blue 3” vinyl cove base on HA-2
ND
4th floor southwest corner at window „deletes‟ 1-2
1-3
2-4
Gypsum wall board system ND all layers
4th floor southwest corner at window „deletes‟ 2-5
2-6
3-7 Dark grey/black, soft/elastic, window frame sealant on metal-frame windows
ND
Floors 2 through 4 south half of structure, and 1st floor 3-8
3-9
4-10 Black, soft/gummy, window frame sealant on metal-frame windows
(weathered appearance)
ND
Throughout building interior 4-11
4-12
5-13 Dark brown, hard/dense, window frame sealant on metal-frame windows
ND
Floors 2 through 4 north half of structure 5-14
5-15
6-16
Exterior wall plaster on concrete (also under HA-9)
ND
Throughout building exterior
6-17 6-18 6-19 6-20 6-21 6-22
7-23
Interior wall plaster on concrete ND Throughout building interior
7-24 7-25
7-26 7-27 7-28 7-29
8-30 Historical tar paper/asphalt roofing on concrete, under
North side 2nd floor balcony/emergency exit ramp
HOMOGENEOUS
AREA
SAMPLE NO. DESCRIPTION SAMPLE LOCATION
8-31 historical white membrane roof under current white membrane roof with fiber mat ND all layers 8-32
9-33 EIFS over HA-6
ND
Throughout building exterior 9-34
9-35 ND – non detect SF – square feet LF – linear feet EA – each HA – homogenous area
APPENDIX B
LEAD-BASED PAINT SAMPLE SUMMARY
USCG-BASE SEATTLE, BUILDING 1
Sample
ID
Color Substrate Component Sample Location Lab Result
(% by weight)
Condition (Intact, Fair, or Poor)
Pb-01
Cream-beige over tan, orange,
lt. green
(and other colors)
Metal Balcony/ramp handrail 2nd floor exterior balcony 14% Fair
Pb-02 Light blue-grey
Wood ‘Shed’ roof rafters 2nd floor balcony/ramp ‘shed’ 2.5% Fair
Pb-03 Tan (accent)
EIFS
Exterior walls Building exterior 0.013%1 Intact Plaster
Pb-04 Off-white
EIFS
Exterior walls Building exterior 0.011%1 Intact Plaster
Pb-05
Cream-beige over tan, orange (and other colors)
Metal Railing 5th floor façade balcony railing
20% Poor
Pb-06 Tan Metal Gutter downspout 3rd/4th floor roof
‘courtyard’ 0.092%1 Poor
Pb-07 Off-white Metal Gas line Ground level on south wall 0.015%1 Fair
Pb-08 White over tan (and other colors) Plaster Interior walls 4th floor <0.010 Intact
Bold sample text denotes lead-based paint 1Lead containing paint
APPENDIX C
PCB PAINT SAMPLE SUMMARY
USCG-BASE SEATTLE, BUILDING 1
Sample
ID
Color Substrate Component Sample Location Lab Result
(Mg/Kg)
Condition (Intact, Fair, or Poor) PCB-01 Off-white EIFS Exterior Walls 1st Floor Exterior ND Intact PCB-02 Grey EIFS Column Accent 1st Floor Exterior ND Intact PCB-03 Tan EIFS Exterior Walls 2nd Floor Exterior ND Intact
APPENDIX D
CHAIN OF CUSTODY AND LABORATORY ANALYTICAL REPORTS
Client Sample Description ConcentrationLab ID Analyzed Lead
Collected
EMSL Analytical, Inc.
200 Route 130 North, Cinnaminson, NJ 08077 Phone/Fax: (856) 303-2500 / (856) 786-5974 http://www.EMSL.com cinnaminsonleadlab@emsl.com
Attn: Chad Kean, CHMM, CPSWQ Terracon Consultants, Inc.
21905 64th Ave. W.
Suite 100 Mountlake Terrace, WA 98043
Received: 02/24/14 9:19 AM
81147014
Fax: (425) 771-3549 Phone: (425) 771-3304
Project:
2/18/2014Collected:
Test Report: Lead in Paint Chips by Flame AAS (SW 846 3050B/7000B)*
201402198 CustomerID: TCWA25 CustomerPO:
ProjectID:
EMSL Order:
Site: 2nd Level Handrail 0001Pb-01 14 % wt2/26/20142/18/2014
Site: Wood Rafters Ramp-"Shed" 0002Pb-02 2.5 % wt2/26/20142/18/2014
Site: EIFS Column Accent 0003Pb-03 0.013 % wt2/26/20142/18/2014
Site: EIFS 0004Pb-04 0.011 % wt2/26/20142/18/2014
Site: 5th Floor Facad Balc.Rail 0005Pb-05 20 % wt2/26/20142/18/2014
Site: Metal Downspout 3rd/4th 0006Pb-06 0.092 % wt2/26/20142/18/2014
Site: Metal Gas Conduit 0007Pb-07 0.015 % wt2/26/20142/18/2014
Site: Interior Walls 0008Pb-08 <0.010 % wt2/26/20142/18/2014
Julie Smith - Laboratory Director NJ-NELAP Accredited:03036 or other approved signatory
Test Report ChmSnglePrm/nQC-7.21.0 Printed: 2/27/2014 12:03:05 PM
*Analysis following Lead in Paint by EMSL SOP/Determination of Environmental Lead by FLAA. Reporting limit is 0.010 % wt based on the minimum sample weight per our SOP. The QC data associated with these results included in this report meet the method QC requirements, unless specifically indicated otherwise. Unless noted, results in this report are not blank corrected. EMSL bears no responsibility for sample collection activities. Samples received in good condition unless otherwise noted. * slight modifications to methods applied. "<" (less than) result signifies that the analyte was not detected at or above the reporting limit. Measurement of uncertainty is available upon request.
Samples analyzed by EMSL Analytical, Inc. Cinnaminson, NJ NELAP Certifications: NJ 03036, NY 10872, PA 68-00367, AIHA-LAP, LLC ELLAP 100194, A2LA 2845.01
Initial report from 02/27/2014 12:03:05 http://www.EMSL.com mailto:cinnaminsonleadlab@emsl.com
Client Evelyn Ahulu 03/05/2014 Nick Ly 03/05/2014
1 Client:
Address:
Attention: Mr. Chad Kean 1519 Alaskan Way S.
81147014
Terracon- MLT 21905 64th Ave. W #100 Mountlake Terrace, WA 98043
Project Location:
NVL Batch No.
Date Received: 3/4/2014
1403698.00
Client Project #:
Samples Received:
Samples Analyzed:
Analyzed by: Date:
Sampled by:
Preparation of these samples were conducted in accordance with EPA Method 3546 or other published test methods as noted in this report. Unless stated otherwise, the condition of all samples was acceptable at time of receipt. Reported sample results are based on dry weight and method QC results are acceptable unless stated otherwise. If samples were not collected by NVL personnel, then the accuracy of the results is limited by the methodology and acuity of the sample collector. This report shall not be reproduced except in full, without written approval of NVL Laboratories, Inc.. Responsibility for interpretation of the reported data rests with the client.
Reviewed by: Date:
14023754
PCB-01
Off white on E. I. F. S.
/Plaster-1st floor field
1.8262 mg/Kg(ppm)
Lab Sample ID:
Client Sample ID:
Sample Description:
Sample Weight (g)
Aroclor 1016 ND
Aroclor 1221 ND
Aroclor 1232 ND
Aroclor 1242 ND
Aroclor 1248 ND
Aroclor 1254 ND
Aroclor 1260 ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
14023755
PCB-02
Grey on E. I. F. S.
column accent
2.0577 mg/Kg(ppm)
14023756
PCB-03
Tan on E. I. F. S. level 2+
2.0849 mg/Kg(ppm)
Reporting Limit (RL) 1.0 1.0
Nick Ly, Technical Director
Matrix:
Method No.:
PCB Type
EPA 8082
Bulk
ND = None Detected (less than RL) <RL = Below the reporting limit of instrument
Remarks: mg/Kg = Milligrams per kilograms ppm = Parts per million by weight
1.1 ND ND NDTotal: PCB Concentration
Polychlorinated Biphenyls (PCBs) Analysis Report
APPENDIX E
SAMPLE LOCATION PLANS
Work area layouts provided by USCG Civil Engineering Unit Oakland, CA
6-21
3-9
6-16
9-337-29
5-13
6-18
3-8
8-31
5-14
7-28
4-11
8-32
6-17
4-12
5-15
8-30
First Floor Plan Second Floor Plan
Pb-03 Pb-04
Pb-07
PCB-01
PCB-02
PCB-03
Project Mngr:
Approved By:
Checked By:
Drawn By:
Project No.
Scale:
Date:
File No. Consulting Engineers and Scientists
FIG. No.
21905 64th Avenue W, Ste 100 Mountlake Terrace, WA 98043 FAX. (425) 771-3549PH. (425) 771-3304 EnviroApplications, Inc.
Seattle, King County, Washington USCG-Base Seattle, Bldg. 1 - 1519 Alaskan Way South
First and Second Floor Sample Locations
March 2014
*.dwg
Not to scale
81147014
CDK
CDK
AAS
CDK
6-19
7-27
4-10
9-34
7-26, Pb-08
7-24
7-25
6-20
2-4
1-1, 1-2, 1-3
2-5
2-6
Work area layouts provided by USCG Civil Engineering Unit Oakland, CA
Third Floor Plan Fourth Floor Plan
Pb-06
Project Mngr:
Approved By:
Checked By:
Drawn By:
Project No.
Scale:
Date:
File No. Consulting Engineers and Scientists
FIG. No.
21905 64th Avenue W, Ste 100 Mountlake Terrace, WA 98043 FAX. (425) 771-3549PH. (425) 771-3304 EnviroApplications, Inc.
Seattle, King County, Washington USCG-Base Seattle, Bldg. 1 - 1519 Alaskan Way South
Third and Fourth Floor Sample Locations
March 2014
*.dwg
Not to scale
81147014
CDK
CDK
7-23
9-35
6-22
3-7
Work area layouts provided by USCG Civil Engineering Unit Oakland, CA
Fifth Floor and Roof Plan South Exterior Elevation Plan
Pb-01
Pb-02
Pb-05
Project Mngr:
Approved By:
Checked By:
Drawn By:
Project No.
Scale:
Date:
File No. Consulting Engineers and Scientists
FIG. No.
21905 64th Avenue W, Ste 100 Mountlake Terrace, WA 98043 FAX. (425) 771-3549PH. (425) 771-3304 EnviroApplications, Inc.
Seattle, King County, Washington USCG-Base Seattle, Bldg. 1 - 1519 Alaskan Way South
Fifth Floor and Roof Sample Locations
March 2014
*.dwg
Not to scale
81147014
CDK
CDK
APPENDIX F
TRAINING CERTIFICATES
| OrderID1: OrderID: 201402198 |
| Page_Number_1: Page 1 Of |
| Total_Pages_1: 2 |
| OrderID2: OrderID: 201402198 |
| Page_Number_2: Page 2 Of |
| Total_Pages_2: 2 |
File details come from the government source that posted it.