This is an Amendment of Solicitation/Modification of Contract for a U.S. Coast Guard contract (Amendment Control Number: 70Z08525RLREP0018). The amendment serves two primary purposes: 1) to provide a list of questions and responses from potential contractors, and 2) to provide Specification Revision 1 dated 11 September 2025. The questions and responses cover various technical details for Work Item 1 and Work Item 2, including clarifications about equipment availability, component procurement, and specific technical specifications.

Key technical clarifications include confirmation that an Allied dual point davit will be available, center bolts are not included and must be provided by the contractor, refrigerant cannot be reused, and estimated quantities for pipe hangers, valves, fittings, and flanges. The amendment also updates the Consolidated List of References, addressing questions about specific Coast Guard drawings and technical specifications for work related to air conditioning plants, seawater cooling systems, and hydraulic piping modifications. The contract is administered by Commander, USCG-SFLC-CPD 2 in Baltimore, MD, with an effective date of 09/12/2025.

View the file

Other files

Show all 15

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:

(a) By completing items 8 and 15, and returning or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

E. IMPORTANT: Contractor is not is required to sign this document and return copies to the issuing office.

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT 1. CONTRACT ID CODE

2. AMENDMENT/MODIFICATION NUMBER 3. EFFECTIVE DATE 4. REQUISITION/PURCHASE REQUISITION NUMBER 5. PROJECT NUMBER (If applicable)

7. ADMINISTERED BY (If other than Item 6) CODE

STANDARD FORM 30 (REV. 11/2016)

Prescribed by GSA FAR (48 CFR) 53.243

FACILITY CODE

9A. AMENDMENT OF SOLICITATION NUMBER

9B. DATED (SEE ITEM 11)

10A. MODIFICATION OF CONTRACT/ORDER NUMBER

10B. DATED (SEE ITEM 13)

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers is extended. is not extended.

12. ACCOUNTING AND APPROPRIATION DATA (If required) copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.

IT MODIFIES THE CONTRACT/ORDER NUMBER AS DESCRIBED IN ITEM 14.

CHECK ONE A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER

NUMBER IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation data, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority)

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15C. DATE SIGNED

15A. NAME AND TITLE OF SIGNER (Type or print)

16C. DATE SIGNED

16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

PAGE OF PAGES

6. ISSUED BY CODE

8. NAME AND ADDRESS OF CONTRACTOR (Number, street, county, State and ZIP Code) (X)

CODE

15B. CONTRACTOR/OFFEROR

(Signature of person authorized to sign)

16B. UNITED STATES OF AMERICA

(Signature of Contracting Officer)

Previous edition unusable

1 3

70Z08525RLREP00180004 09/12/2025

70Z08525RLREP0018

09/10/2025

70Z085

AMENDMENT CONTROL NUMBER : 70Z08525RLREP0018

SUMMARY OF CHANGES : AMEND-To list questions and responses and to provide an updated specification.

Same As Issuing Office 70Z085 CPD 2 - Baltimore, MD Commander, USCG-SFLC-CPD 2, 2401 Hawkins Point Road Baltimore, MD, 21226, US

70Z085

70Z08525RLREP00180004

Summary of Changes

The purpose of this amendment is to do the following:

1) Provide a list of the following questions and responses:

2) Provide Specification Revision 1 dated 11 September 2025

Question 8: Specification Paragraph Reference:

Work Item 2- Allied OEM stated USCG does not have a Allied dual point davit on hand/available to complete the side davit renewal as indicated the work item. May you please confirm if there is a davit available for this work and confirm it is Allied brand, as indicated by the GFP table in 1.2?

Response: The Government can confirm that there will be a davit available for this work. And can confirm that it is the Allied brand indicated in the GFE table in 1.2.

Question 9:

Specification Paragraph Reference: Work Item 1, Various paragraphs

Table 1.2: TP S9514-F1-MMA-010 states center bolts are provided with mounts, can you please confirm? 18 center bolts specified in the drawing are $560.00 so we want to confirm they're provided.

Response: These bolts are not included and must be provided by the contractor.

3.4.2 & 3.18: Can the refrigerant be reused? Reusing refrigerant would save $30,000.00.

Response: The refrigerant must be renewed per the specifications. It cannot be reused.

3.7.5: Relief valves are stated to be GFP but not included in table 1.2. Please confirm if these are GFP or CFP?

Response: This is a mistake. They should be CFP

3.21: May you please specify, for bidding purposes, how many pipe hangers, valves, fittings, and flanges to estimate needing insulation renewed within the 75ft?

Response: Estimate 25 hangars, 25 valves, 75 fittings, and 75 flanges

Question 10:

Coast Guard Drawing 750-WMSL-320-580 is not listed in the consolidated list of references but it appears to play a major role in the work being completed in Work Item 2, Paras 3.5.5, 3.5.6, and 3.6. May we please have access to this drawing?

Response: See Specification Revision 1 dated 11 September 2025, which contains updated a Consolidated List of References.

Question 11:

70Z08525RLREP00180004

Coast Guard Drawing 750-WMSL-583-518, Rev D, Hydraulic Piping Mods IWO Dual Point Davit Installation is what is referenced in the consolidated list of references, but we received Rev E. Is Rev E an acceptable update that does not conflict with Rev D? We want to make sure we're able to accurately quote the work being asked of us.

Response: See Specification Revision 1 dated 11 September 2025, which contains updated a Consolidated List of References as 750-WMSL-583-518, Rev E.

Question 12:

Specification Paragraph Reference: Work Item 1 Air Conditioning Plants, Groom:

Please provide Coast Guard Drawing 750-WMSL-520-004, Rev H, Seawater Cooling System Unit 1320, which was not included in the technical documents. For situational awareness, it is not listed in the Consolidated List of References at the beginning of the work package, but it is listed in section 2 References for Work Item 1.

Response: See Specification Revision 1 dated 11 September 2025, which contains updated a Consolidated List of References.

Question 13:

Specification Paragraph Reference: Work Item 1, 3.7.6:

The AC Tech Rep mentioned the rupture disks were recently replaced on JAMES and due to the high price of the rupture disks, requests to know if they have been damaged or if this portion of the work item is not needed due to the recent groom and renewal. The AC Tech Rep also noted the rupture disks are usually GFM and wants to confirm they will be CFM, if this portion of the work will be completed.

Response: This will be GFE.