Attachment 1 - HARRY CLAIBORNE DD FY22 - BLANK - R1.xls
XLS spreadsheet 126 KB Posted
- Attached to
- USCG Harry Claiborne FY 22 - Dry Dock
- Solicitation number
- 70Z085-22-Q-P4505300
About this file
This combined synopsis and solicitation requests quotations for dry dock repairs of the US Coast Guard Cutter Harry Claiborne. The contractor shall provide all necessary labor, materials, services, and equipment to perform various repairs in accordance with the attached specifications. The performance period is March 15 through May 24, 2022. The place of performance is the contractor's proposed dry dock facility. The solicitation is set aside for small businesses and issued as a firm fixed price contract under FAR Part 12 and Subpart 13.5. Quotations are due by January 10, 2022, and award is anticipated on or around February 15, 2022. Questions regarding the solicitation must be submitted by December 20, 2021, and requests for drawings are due by December 17, 2021. The NAICS code is 336611 and small business size standard is 1,250 employees.
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SOS&S
| GOVERNMENT ESTIMATE FOR: | APM | ||||
| USCGC HARRY CLAIBORNE (WLM-175) DRYDOCK AVAILABILITY FY2022 | Date Spec Due | ||||
| Date Est Due | |||||
| ITEM | DESCRIPTION | UNIT PRICE | UNIT | QTY | EXTENDED PRICE |
| D-001 | Hull Plating, U/W Body, Inspect | JOB | 1 | $0.00 | |
| D-002 | Hull Plating, U/W Body, Ultrasonic Testing | JOB | 1 | $0.00 | |
| D-003 | U/W Body, Preserve (100%) | JOB | 1 | $0.00 | |
| D-004 | Appendages, U/W, Leak Test | JOB | 1 | $0.00 | |
| D-005 | Appendages, U/W, Internal, Preserve | JOB | 1 | $0.00 | |
| D-006 | Chain Lockers, Clean and Inspect | JOB | 1 | $0.00 | |
| D-007 | Tanks, MP Fuel Stowage and Overflow, Clean and Inspect | JOB | 1 | $0.00 | |
| D-008 | Tanks, MP Fuel Service, Clean and Inspect | JOB | 1 | $0.00 | |
| D-009 | Tanks, Ballast, Clean and Inspect | JOB | 1 | $0.00 | |
| D-010 | Tanks, Dirty Oil and Waste, Clean and Inspect | JOB | 1 | $0.00 | |
| D-011 | Sea Valves and Waster Pieces, Overhaul Or Renew | JOB | 1 | $0.00 | |
| D-012 | Sea Bay, Clean and Inspect | JOB | 1 | $0.00 | |
| O-013 | Sea Bay, Preserve 100% | JOB | 1 | $0.00 | |
| D-014 | Thruster Unit (General), Overhaul | JOB | 1 | $0.00 | |
| D-015 | Anchor Windlass, Inspect And Service | JOB | 1 | $0.00 | |
| D-016 | Anchor Chains and Ground Tackle, Inspect and Repair | JOB | 1 | $0.00 | |
| O-017 | Chain Locker, Preserve, Partial | JOB | 1 | $0.00 | |
| D-018 | Decks – Exterior (Buoy or Construction Deck), Preserve 100% | JOB | 1 | $0.00 | |
| D-019 | Cathodic Protection, Zinc Anodes, Renew, | JOB | 1 | $0.00 | |
| D-020 | Drydock | JOB | 1 | $0.00 | |
| D-021 | Temporary Services, Provide - Cutter | JOB | 1 | $0.00 | |
| D-022 | Sea Trial Performance, Support, Provide | JOB | 1 | $0.00 | |
| D-023 | Fan Space, Inspect and Preserve/Renew | JOB | 1 | $0.00 | |
| D-024 | Crane Winch DCV, Replace | JOB | 1 | $0.00 | |
| O-025 | Auxiliary Sea Water Piping, Modify | JOB | 1 | $0.00 | |
| D-026 | Hull Plating, Side Scan, Ultrasonic Testing | JOB | 1 | $0.00 | |
| O-027 | Hull and Structural Plating, General, 10.2 lbs. Steel, Renew | JOB | 1 | $0.00 | |
| O-028 | Hull and Structural Plating, General, 12.75 lbs. Steel Plate, Renew | JOB | 1 | $0.00 | |
| O-029 | Hull and Structural Plating, General, 15.3 lbs. Steel Plate, Renew | JOB | 1 | $0.00 | |
| O-030 | Hull And Structural Plating, General, 20.4 lbs. Steel Plate, Renew | JOB | 1 | $0.00 | |
| O-031 | Hull and Structural Plating, General, 7.5 lbs., 3/16 in. Steel Plate, Renew | JOB | 1 | $0.00 | |
| O-032 | Hull and Structural Plating, General, 7.65 lbs. Steel Plate, Renew | JOB | 1 | $0.00 | |
| O-033 | Hull And Structural Plating, General, Cracked Steel Welds, Repairs | JOB | 1 | $0.00 | |
| O-034 | Hull and Structural Plating, General, Degraded Weld, Steel, Repair | JOB | 1 | $0.00 | |
| D-035 | Voids, Non-Accessible, Internal Surfaces, Preserve | JOB | 1 | $0.00 | |
| D-036 | Voids, Accessible, Clean and Inspect | JOB | 1 | $0.00 | |
| D-037 | Hydraulically Operated Cargo Hatch, Inspect and Service | JOB | 1 | $0.00 | |
| D-038 | Masts (Main, Fwd, and Task Light), Preserve | JOB | 1 | $0.00 | |
| D-039 | Fathometer Transducer, General Maintenance | JOB | 1 | $0.00 | |
| D-040 | Underwater Speed Log Transducers, Service and Inspect | JOB | 1 | $0.00 | |
| O-041 | Sea Bay, Preserve - Partial | JOB | 1 | $0.00 | |
| D-042 | Hydraulic Chain Stoppers, Inspect And Service | JOB | 1 | $0.00 | |
| D-043 | Mechanical Chain Stoppers, Inspect and Service | JOB | 1 | $0.00 | |
| D-044 | Grey Water Holding Tanks, Clean and Inspect | JOB | 1 | $0.00 | |
| D-045 | Sewage Holding Tanks, Clean and Inspect | JOB | 1 | $0.00 | |
| D-046 | Grey Water Piping, Clean and Flush | JOB | 1 | $0.00 | |
| D-047 | Sewage Piping, Clean and Flush | JOB | 1 | $0.00 | |
| O-048 | Tanks (Grey Water Holding), Preserve “Partial” | JOB | 1 | $0.00 | |
| O-049 | Tanks (Sewage Holding), Preserve “Partial” | JOB | 1 | $0.00 | |
| O-050 | Tanks, Ballast, Preserve, Partial | JOB | 1 | $0.00 | |
| D-051 | Hull Plating Freeboard, Preserve, 100 Percent | JOB | 1 | $0.00 | |
| D-052 | Superstructure, Preserve, 100 Percent | JOB | 1 | $0.00 | |
| D-053 | Small Boat Davit Console Foundation, Renew | JOB | 1 | $0.00 | |
| D-054 | Buoy-Deck Beam, Renew | JOB | 1 | $0.00 | |
| D-055 | Windows Framing and Gaskets, Renew | JOB | 1 | $0.00 | |
| D-056 | Bilges, Preserve | JOB | 1 | $0.00 | |
| D-057 | Compartment Insulation, General, Renew | JOB | 1 | $0.00 | |
| D-058 | Deck Covering, Interior, Wet and Dry, Renew | JOB | 1 | $0.00 | |
| D-059 | Deck Drains, Renew (Various Compartments) | JOB | 1 | $0.00 | |
| D-060 | Exhaust Stack Inspection Cover Studs, Renew | JOB | 1 | $0.00 | |
| D-061 | Vents, Preserve and Closures, Renew | JOB | 1 | $0.00 | |
| D-062 | Port Button Roller Chock, Renew | JOB | 1 | $0.00 | |
| D-063 | Sounding Tube, Renew | JOB | 1 | $0.00 | |
| O-064 | Accessible Void(s), Preserve, Partial | JOB | 1 | $0.00 | |
| D-065 | Weather Deck Kickpipes, Renew. | JOB | 1 | $0.00 | |
| D-066 | Portable Davit Brackets and Liner Sleeve, Renew | JOB | 1 | $0.00 | |
| D-067 | 175’ WLM H2S Gas Detector, Replace. | JOB | 1 | $0.00 | |
| D-068 | Weather Deck Non-Skid, MIL-SPEC Coating | JOB | 1 | $0.00 | |
| D-069 | Window Wiper Modifications, Install | JOB | 1 | $0.00 | |
| D-070 | Equipment Foundations, Renew | JOB | 1 | $0.00 | |
| D-071 | Heat Pump System, Overhaul | JOB | 1 | $0.00 | |
| O-072 | Sea Bay / Sea Chest Piping, Modify | JOB | 1 | $0.00 | |
| O-00A | Composite Labor Rate | Hour | 1 | 0 | |
| D-00B | GFP Report | NSP | EA | NSP | |
| O-00Z | Laydays | Day | 5 | $0.00 | |
| Total Price of Definite Items | $0.00 | ||||
| Total Price of Option Items | $0.00 | ||||
| Total Price of Definite and Optional Items | $0.00 |
Page &P of &N
CostEstimateBreakdowns
| Composite Labor Rate | 55 | |||||||||||||||||||||||
| Assumed G&A Factor | 15% | |||||||||||||||||||||||
| Assumed Profit Factor | 10% | Direct Labor | Direct Material/Subs Cost | |||||||||||||||||||||
| ITEM | DESCRIPTION | UNIT PRICE | Sub-Contracted (put a "1" in the blank) | Total Labor Hours | Total Material & Subs (cost + G&A + profit) | Eng Tech | Machinest/Pipe Fitter | Electrician | Shipfitter | Welder | Firewatch | Insulator/Lagger | Painter | Gen Labor/Helper/Rigger | Supt/QA/NDT | Mat/Sub Cost 1 | Mat/Sub Cost 2 | Mat/Sub Cost 3 | Mat/Sub Cost 4 | Lab Rate | Area | WorkItemID | WIFileID | LoadData |
| D-001 | Hull Plating, U/W Body, Inspect | $ - 0 | 0 | 0 | 62 | Baltimore, MD | 5089 | 1 | 74 | |||||||||||||||
| D-002 | Hull Plating, U/W Body, Ultrasonic Testing | $ - 0 | 0 | 0 | 52 | Biloxi, MS | 23 | 1 | 15 | |||||||||||||||
| D-003 | U/W Body, Preserve (100%) | $ - 0 | 0 | 0 | 56 | Boston, MA | 1705 | 1 | WLM 175 | |||||||||||||||
| D-004 | Appendages, U/W, Leak Test | $ - 0 | 0 | 0 | 50 | Charleston, SC | 5158 | 1 | 0 | |||||||||||||||
| D-005 | Appendages, U/W, Internal, Preserve | $ - 0 | 0 | 0 | 60 | Corpus Christi, TX | 42 | 1 | 1 | |||||||||||||||
| D-006 | Chain Lockers, Clean and Inspect | $ - 0 | 0 | 0 | 51 | Hampton Roads | 46 | 1 | 52 | |||||||||||||||
| D-007 | Tanks, MP Fuel Stowage and Overflow, Clean and Inspect | $ - 0 | 0 | 0 | 64 | Honolulu, HI | 51 | 1 | FY2022 | |||||||||||||||
| D-008 | Tanks, MP Fuel Service, Clean and Inspect | $ - 0 | 0 | 0 | 55 | Houston, TX | 9875 | 1 | DD | |||||||||||||||
| D-009 | Tanks, Ballast, Clean and Inspect | $ - 0 | 0 | 0 | 56 | Los Angeles, CA | 3996 | 1 | cutter | |||||||||||||||
| D-010 | Tanks, Dirty Oil and Waste, Clean and Inspect | $ - 0 | 0 | 0 | 55 | Median Rate | 81 | 1 | HARRY CLAIBORNE (WLM 175) DD FQ2 GNC 22D4.doc | |||||||||||||||
| D-011 | Sea Valves and Waster Pieces, Overhaul Or Renew | $ - 0 | 0 | 0 | 49 | Miami | 2065 | 1 | ||||||||||||||||
| D-012 | Sea Bay, Clean and Inspect | $ - 0 | 0 | 0 | 50 | Narragansett Bay, RI | 2774 | 1 | ||||||||||||||||
| D-013 | Sea Bay, Preserve 100% | $ - 0 | 0 | 0 | 55 | New London, CN | 2775 | 1 | ||||||||||||||||
| D-014 | Thruster Unit (General), Overhaul | $ - 0 | 0 | 0 | 45 | New Orleans | 6679 | 1 | ||||||||||||||||
| D-015 | Anchor Windlass, Inspect And Service | $ - 0 | 0 | 0 | 62 | NYNY | 7706 | 1 | ||||||||||||||||
| D-016 | Anchor Chains and Ground Tackle, Inspect and Repair | $ - 0 | 0 | 0 | 49 | Panama City, FL | 718 | 1 | ||||||||||||||||
| D-017 | Chain Locker, Preserve, 100 Percent | $ - 0 | 0 | 0 | 60 | Philadelphia, PA | 2416 | 1 | ||||||||||||||||
| D-018 | Decks – Exterior (Buoy or Construction Deck), Preserve 100% | $ - 0 | 0 | 0 | 51 | Portland, ME | 2865 | 1 | ||||||||||||||||
| D-019 | Cathodic Protection, Zinc Anodes, Renew, | $ - 0 | 0 | 0 | 57 | Portland, OR | 542 | 1 | ||||||||||||||||
| D-020 | Drydock | $ 63,375.00 | 675 | 26250 | $675.00 | $21,000.00 | 55 | San Diego, CA | 555 | 1 | ||||||||||||||
| D-021 | Temporary Services, Provide - Cutter | $ - 0 | 0 | 0 | 67 | San Francisco, CA | 556 | 1 | ||||||||||||||||
| D-022 | Sea Trial Performance, Support, Provide | $ - 0 | 0 | 0 | 55 | Santa Barbara, CA | 563 | 1 | ||||||||||||||||
| D-023 | Superstructure Surfaces (Buoy Deck Area), Preserve | $ - 0 | 0 | 0 | 55 | SE North Carolina | 5311 | 1 | ||||||||||||||||
| D-024 | Crane Winch DCV, Replace | $ - 0 | 0 | 0 | 65 | Seattle, WA | 10208 | 1 | ||||||||||||||||
| D-025 | Auxiliary Sea Water Piping, Modify | $ - 0 | 0 | 0 | 48 | Tampa-St. Petersburg | 1499 | 1 | ||||||||||||||||
| D-026 | Hull Plating, Side Scan, Ultrasonic Testing | $ - 0 | 0 | 0 | 60 | Wilmington, DE | 3998 | 1 | ||||||||||||||||
| D-027 | Hull and Structural Plating, General, 10.2 lbs. Steel, Renew | $ - 0 | 0 | 0 | 1762 | 1 | ||||||||||||||||||
| D-028 | Hull and Structural Plating, General, 12.75 lbs. Steel Plate, Renew | $ - 0 | 0 | 0 | 1763 | 1 | ||||||||||||||||||
| D-029 | Hull and Structural Plating, General, 15.3 lbs. Steel Plate, Renew | $ - 0 | 0 | 0 | 1764 | 1 | ||||||||||||||||||
| D-030 | Hull And Structural Plating, General, 20.4 lbs. Steel Plate, Renew | $ - 0 | 0 | 0 | 1765 | 1 | ||||||||||||||||||
| D-031 | Hull and Structural Plating, General, 7.5 lbs., 3/16 in. Steel Plate, Renew | $ - 0 | 0 | 0 | 750 | 1 | ||||||||||||||||||
| D-032 | Hull and Structural Plating, General, 7.65 lbs. Steel Plate, Renew | $ - 0 | 0 | 0 | 2494 | 1 | ||||||||||||||||||
| D-033 | Hull And Structural Plating, General, Cracked Steel Welds, Repairs | $ - 0 | 0 | 0 | 2442 | 1 | ||||||||||||||||||
| D-034 | Hull and Structural Plating, General, Degraded Weld, Steel, Repair | $ - 0 | 0 | 0 | 1212 | 1 | ||||||||||||||||||
| D-035 | Voids, Non-Accessible, Internal Surfaces, Preserve | $ - 0 | 0 | 0 | 10676 | 1 | ||||||||||||||||||
| D-036 | Voids, Accessible, Clean and Inspect | $ - 0 | 0 | 0 | 5420 | 1 | ||||||||||||||||||
| D-037 | Hydraulically Operated Cargo Hatch, Inspect and Service | $ - 0 | 0 | 0 | 9591 | 1 | ||||||||||||||||||
| D-038 | Masts (Main, Fwd, and Task Light), Preserve, 100 Percent | $ - 0 | 0 | 0 | 532 | 1 | ||||||||||||||||||
| D-039 | Fathometer Transducer, General Maintenance | $ - 0 | 0 | 0 | 10101 | 1 | ||||||||||||||||||
| D-040 | Underwater Speed Log Transducers, Service and Inspect | $ - 0 | 0 | 0 | 9784 | 1 | ||||||||||||||||||
| D-041 | Sea Bay, Preserve - Partial | $ - 0 | 0 | 0 | 2773 | 1 | ||||||||||||||||||
| D-042 | Hydraulic Chain Stoppers, Inspect And Service | $ - 0 | 0 | 0 | 5427 | 1 | ||||||||||||||||||
| D-043 | Mechanical Chain Stoppers, Inspect and Service | $ - 0 | 0 | 0 | 7710 | 1 | ||||||||||||||||||
| D-044 | Sewage Valve(s), Overhaul | $ - 0 | 0 | 0 | 449 | 1 | ||||||||||||||||||
| D-045 | Grey Water Holding Tanks, Clean and Inspect | $ - 0 | 0 | 0 | 9871 | 1 | ||||||||||||||||||
| D-046 | Sewage Holding Tanks, Clean and Inspect | $ - 0 | 0 | 0 | 9873 | 1 | ||||||||||||||||||
| D-047 | Grey Water Piping, Clean and Flush | $ - 0 | 0 | 0 | 9874 | 1 | ||||||||||||||||||
| D-048 | Sewage Piping, Clean and Flush | $ - 0 | 0 | 0 | 455 | 1 | ||||||||||||||||||
| D-049 | Tanks (Grey Water Holding), Preserve “Partial” | $ - 0 | 0 | 0 | 497 | 1 | ||||||||||||||||||
| D-050 | Tanks (Sewage Holding), Preserve “Partial” | $ - 0 | 0 | 0 | 501 | 1 | ||||||||||||||||||
| D-051 | Tanks, Ballast, Preserve, Partial | $ - 0 | 0 | 0 | 489 | 1 | ||||||||||||||||||
| D-052 | Hull Plating Freeboard (Buoy Port Areas), Preserve | $ - 0 | 0 | 0 | 5295 | 1 | ||||||||||||||||||
| D-053 | Superstructure, Preserve, 100 Percent | $ - 0 | 0 | 0 | 5044 | 1 | ||||||||||||||||||
| D-054 | Superstructure, Preserve, Partial | $ - 0 | 0 | 0 | 5045 | 1 | ||||||||||||||||||
| D-055 | Exhaust Stacks (Exterior), Preserve - Partial | $ - 0 | 0 | 0 | 5392 | 1 | ||||||||||||||||||
| D-056 | Auxiliary Sea Water System Valves, Overhaul Or Renew | $ - 0 | 0 | 0 | 671 | 1 | ||||||||||||||||||
| D-057 | Bilges, Inspect | $ - 0 | 0 | 0 | 10066 | 1 | ||||||||||||||||||
| D-058 | Bilges, Preserve | $ - 0 | 0 | 0 | 5139 | 1 | ||||||||||||||||||
| D-059 | Compartment Insulation, General, Renew | $ - 0 | 0 | 0 | 688 | 1 | ||||||||||||||||||
| D-060 | Deck Covering, Interior, Wet and Dry, Renew | $ - 0 | 0 | 0 | 1731 | 1 | ||||||||||||||||||
| D-061 | Space or Component, Preserve | $ - 0 | 0 | 0 | 684 | 24 | ||||||||||||||||||
| D-062 | System Piping, Renew | $ - 0 | 0 | 0 | 9549 | 1 | ||||||||||||||||||
| D-063 | Vent Ducts, Renew | $ - 0 | 0 | 0 | 1334 | 1 | ||||||||||||||||||
| D-064 | Port Button Roller Chock, Renew | $ - 0 | 0 | 0 | 10000 | 0 | ||||||||||||||||||
| D-065 | Sounding Tube, Renew | $ - 0 | 0 | 0 | 10000 | 0 | ||||||||||||||||||
| D-066 | Thruster Unit Pinion Seal, Renew | $ - 0 | 0 | 0 | 10000 | 0 | ||||||||||||||||||
| D-067 | Weather Deck Kickpipes, Renew. | $ - 0 | 0 | 0 | 10000 | 0 | ||||||||||||||||||
| D-068 | Auxiliary Sea Water Piping, Modify | $ - 0 | 0 | 0 | 10000 | 0 | ||||||||||||||||||
| D-069 | 175’ WLM H2S Gas Detector, Replace. | $ - 0 | 0 | 0 | 10000 | 0 | ||||||||||||||||||
| D-070 | Decks - Exterior, Preserve (“Non-Skid Broadcast Grit” System) | $ - 0 | 0 | 0 | 4000 | 1 | ||||||||||||||||||
| D-071 | Window Wiper Modifications, Install | $ - 0 | 0 | 0 | 1483 | 1 | ||||||||||||||||||
| D-072 | Equipment Foundations, Renew | $ - 0 | 0 | 0 | 10000 | 0 | ||||||||||||||||||
| D-073 | Heat Pump System, Overhaul | $ - 0 | 0 | 0 | 10000 | 0 | ||||||||||||||||||
| D-074 | Pilot House Windows Framing and Gaskets, Renew | $ - 0 | 0 | 0 | 10000 | 0 |
&C(09/28/2009) Page &P of &N
CostEstimateTemplate
| Composite Labor Rate | 55 | ||||||||||||||||
| Assumed G&A Factor | 15% | ||||||||||||||||
| Assumed Profit Factor | 10% | Direct Labor | Direct Material/Subs Cost | ||||||||||||||
| Sub-Contracted (put a "1" in the blank) | Total Labor Hours | Total Material & Subs (cost + G&A + profit) | Eng Tech | Machinest/Pipe Fitter | Electrician | Shipfitter | Welder | Firewatch | Insulator/Lagger | Painter | Gen Labor/Helper/Rigger | Supt/QA/NDT | |||||
| DESCRIPTION | UNIT PRICE | Lab Rate | Area | ||||||||||||||
| $0 | 0 | $0 | 62 | Baltimore, MD | |||||||||||||
| $0 | 0 | $0 | 52 | Biloxi, MS | |||||||||||||
| $0 | 0 | $0 | 56 | Boston, MA | |||||||||||||
| $0 | 0 | $0 | 50 | Charleston, SC | |||||||||||||
| $0 | 0 | $0 | 60 | Corpus Christi, TX | |||||||||||||
| $0 | 0 | $0 | 64 | Honolulu, HI | |||||||||||||
| $0 | 0 | $0 | 55 | Houston, TX | |||||||||||||
| $0 | 0 | $0 | 56 | Los Angeles, CA | |||||||||||||
| $0 | 0 | $0 | 55 | Median Rate | |||||||||||||
| $0 | 0 | $0 | 55 | Median Rate | |||||||||||||
| $0 | 0 | $0 | 50 | Narragansett Bay, RI | |||||||||||||
| 55 | New London, CN | ||||||||||||||||
| 45 | New Orleans | ||||||||||||||||
| 62 | NYNY | ||||||||||||||||
| 49 | Panama City, FL | ||||||||||||||||
| 60 | Philadelphia, PA | ||||||||||||||||
| 51 | Portland, ME | ||||||||||||||||
| 57 | Portland, OR | ||||||||||||||||
| 55 | San Diego, CA | ||||||||||||||||
| 67 | San Francisco, CA | ||||||||||||||||
| 55 | Santa Barbara, CA | ||||||||||||||||
| 55 | SE North Carolina | ||||||||||||||||
| 65 | Seattle, WA | ||||||||||||||||
| 48 | Tampa-St. Petersburg | ||||||||||||||||
| 60 | Wilmington, DE |