SOS&S

PRICING SCHEDULE FOR:COMPANY NAME:
USCGC IDA LEWIS (WLM-551) DRYDOCK AVAILABILITY FY2019
ITEMDESCRIPTIONUNIT PRICEUNITQTYEXTENDED PRICE
D-001Hull Plating (Side Scan), Ultrasonic Testing$ - 0JOB1$ - 0
D-002U/W Body, Preserve (100%)$ - 0JOB1$ - 0
D-003Hull Plating Freeboard, Preserve “100%”$ - 0JOB1$ - 0
O-004Hull and Structural Plating (General) -10.2-Pound Steel, Renew$ - 0JOB1$ - 0
O-005Hull and Structural Plating (General) - 12.75-Pound Steel Plate, Renew$ - 0JOB1$ - 0
O-006Hull and Structural Plating (General) - 15.3-Pound Steel Plate, Renew$ - 0JOB1$ - 0
O-007Hull And Structural Plating (General) - 20.4-Pound Steel Plate, Renew$ - 0JOB1$ - 0
O-008Hull and Structural Plating (General) - 7.5-Pound (3/16") Steel Plate, Renew$ - 0JOB1$ - 0
O-009Hull and Structural Plating (General) - 7.5-Pound (3/16") Steel Plate, Renew$ - 0JOB1$ - 0
D-010Appendages (U/W), Leak Test$ - 0JOB1$ - 0
O-011Appendages (U/W) - Internal, Preserve$ - 0JOB1$ - 0
D-012Chain Locker(s), Clean and Inspect$ - 0JOB1$ - 0
D-013Tanks (Mp Fuel Stowage And Overflow), Clean And Inspect$ - 0JOB1$ - 0
D-014Voids (Non-Accessible), Leak Test$ - 0JOB1$ - 0
O-015Voids (Non-Accessible), Internal Surfaces, Preserve$ - 0JOB1$ - 0
D-016Tanks (Mp Fuel Service), Clean And Inspect$ - 0JOB1$ - 0
D-017Tanks (Potable Water), Clean and Inspect$ - 0JOB1$ - 0
D-018Tanks (Lube Oil), Clean and Inspect$ - 0JOB1$ - 0
D-019Tanks (Ballast), Clean and Inspect$ - 0JOB1$ - 0
D-020Tanks (Dirty Oil and Waste), Clean and Inspect$ - 0JOB1$ - 0
D-021Underwater (Speed) Log Transducer(s), Service and Inspect$ - 0JOB1$ - 0
D-022Sea Valves and Waster Pieces, Overhaul or Renew$ - 0JOB1$ - 0
D-023Sea Strainers (All Sizes), Renew$ - 0JOB1$ - 0
O-024Sea Bay, Preserve - Partial$ - 0JOB1$ - 0
O-025Sea Bay, Clean and Inspect$ - 0JOB1$ - 0
O-026Sea Bay, Preserve 100%$ - 0JOB1$ - 0
O-027Thruster Unit (General), Overhaul$ - 0JOB1$ - 0
D-028Anchor Windlass, Inspect And Service$ - 0JOB1$ - 0
D-029Anchor Chain(s) and Ground Tackle, Inspect and Repair$ - 0JOB1$ - 0
D-030Anchor Chain and Ground Tackle, Preserve$ - 0JOB1$ - 0
D-031Anchor(s), Preserve$ - 0JOB1$ - 0
D-032Hawse Pipes, Preserve$ - 0JOB1$ - 0
O-033Tanks (Ballast), Preserve “100%”$ - 0JOB1$ - 0
O-034Tanks (Ballast), Preserve “Partial”$ - 0JOB1$ - 0
O-035Chain Locker, Preserve 100%$ - 0JOB1$ - 0
O-036Chain Lockers, Preserve – Partial$ - 0JOB1$ - 0
O-037Tanks (Dirty Oil and Waste), Preserve “100%”$ - 0JOB1$ - 0
O-038Tanks (Dirty Oil and Waste), Preserve “Partial”$ - 0JOB1$ - 0
O-039Tanks (Potable Water), Preserve “100%”$ - 0JOB1$ - 0
O-040Tanks (Potable Water), Preserve “Partial”$ - 0JOB1$ - 0
D-041Cathodic Protection / Zinc Anodes, Renew$ - 0JOB1$ - 0
D-042Drydock$ - 0JOB1$ - 0
D-043Temporary Services, Provide - Cutter$ - 0JOB1$ - 0
D-044Sea Trial Performance, Support, Provide$ - 0JOB1$ - 0
D-045Bilges, Preserve$ - 0JOB1$ - 0
D-046Hull Plating (Freeboard), Ultrasonic Testing$ - 0JOB1$ - 0
O-047Hull and Structural Plating (General) - Cracked Steel Welds, Repairs$ - 0JOB1$ - 0
D-048Both Main Diesel Engine Mounts, Renewal$ - 0JOB1$ - 0
D-049Both Z-Drive Propulsion Trans, Alignment$ - 0JOB1$ - 0
D-050Z-Drive Propulsion Unit, Renew (Drydock)$ - 0JOB1$ - 0
D-051Sw Heat Exchangers; Clean, Inspect And Hydro$ - 0JOB1$ - 0
D-052Potable Water Pneumatic Tank(s), Clean and Inspect$ - 0JOB1$ - 0
D-053Potable Water System Relief Valve, Overhaul or Renew$ - 0JOB1$ - 0
D-054Thruster Unit (General), Inspect$ - 0JOB1$ - 0
D-055Grey Water Holding Tank(s), Clean and Inspect$ - 0JOB1$ - 0
D-056Sewage Holding Tank(s), Clean and Inspect$ - 0JOB1$ - 0
O-057Tanks (Sewage Holding), Preserve “100%”$ - 0JOB1$ - 0
O-058Tanks (Sewage Holding), Preserve “100%”$ - 0JOB1$ - 0
O-059Tanks (Sewage Holding), Preserve “Partial”$ - 0JOB1$ - 0
O-060Tanks (Sewage Vacuum Collection), Preserve “Partial”$ - 0JOB1$ - 0
O-061Tanks (Grey Water Holding), Preserve “100%”$ - 0JOB1$ - 0
O-062Tanks (Sewage Vacuum Collection), Preserve “100%”$ - 0JOB1$ - 0
D-063Decks – Exterior (Buoy or Construction Deck), Preserve 100%$ - 0JOB$ - 0
D-064Stanchions, Renew$ - 0JOB$ - 0
D-065Lube Oil Transfer System Piping, Renew$ - 0JOB$ - 0
D-066Hydraulic Piping End Fitting, Repair$ - 0JOB$ - 0
D-0673rd Level Deck Plate Repair$ - 0JOB$ - 0
D-068Vent Space, Deck, Preserve$ - 0JOB$ - 0
D-069Pilothouse Windows, Renew$ - 0JOB$ - 0
D-070Oily Water Separator, Replace$ - 0JOB$ - 0
D-071Circuit Breakers (60 Hz), Inspect and Test$ - 0JOB$ - 0
D-072Provide Access to Compartments for SSMEB inspection$ - 0JOB$ - 0
O-00AComposite Labor Rate (Per Hour)$ - 0Hour1070$ - 0
D-00BGFP ReportNSPEANSP
O-00ZLaydays$ - 0DAY5$ - 0
M-00AContractor Markup Rate for Growth Work - G&A + Profit (In Percent)
Total Price of Definite Items:$ - 0
Total Price of Option Items:$ - 0
TOTAL PRICE (Of Definite and Option Items):$ - 0
*** Please CHECK & VERIFY all price submittals for completeness & accuracy. ***
Pricing must include all Travel and Related Expenses.

&"Arial,Bold"&12USCG IDA LEWIS (WLM 551) DD FY19

RFQ NO: 70Z085-19-Q-P4574500

&8Page &P of &N &8Rev: 27Sep18