This document is a detailed product specification for the Liberty Pumps LEH150-Series sewage pumps, covering technical, electrical, and operational characteristics of 1.5 hp submersible pumps designed for sewage applications. The pumps are available in single-phase and three-phase configurations with various voltage options (208-230V, 440-480V, 575V), featuring a Class 25 cast iron construction, semi-open 2-vane impeller, and dual seal arrangement to protect the motor from pumping liquid. Key specifications include handling 2-inch solids, a shut-off head of 70 feet, maximum flow of 200 GPM at 20 feet of total dynamic head, and a minimum application head of 20 feet.
The specification details comprehensive technical requirements, including oil-filled motors with thermal overload protection, stainless steel shaft, angular contact bearings, and a powder-coated exterior. The pumps can be controlled with a piggyback float switch or various NEMA control panels, and are certified by SSPMA and cCSAus. Additional features include a stainless steel handle, cast iron support legs, and a recommended redundant check valve assembly for pressure sewer installations. The pumps come with a 3-year limited warranty, are manufactured in an ISO 9001 certified facility, and undergo rigorous testing including ground continuity checks and performance verification.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Pump Specification
Copyright © Liberty Pumps, Inc. 2025 All rights reserved. Specifications subject to change without notice. LEH150_P1 R04/2025
7000 Apple Tree Avenue Bergen NY 14416 Phone 1-800-543-2550 Fax 1-585-494-1839 Email Liberty@LibertyPumps.com Web www.LibertyPumps.com
LEH150-Series
1.5 hp High Head 2� Solids Handling Sewage Pumps
0.0
3.1
6.1
9.2
12.2
15.3
18.3
21.4
24.4 0 100 200 300 400 500 600 700
0 20 40 60 80 100 120 140 160 180 200
LITERS PER MINUTE
TO
TA
L H
EA
D
IN
FE
ET
US GALLONS PER MINUTE
TO
TA
L H
EA
D
IN
M
ET
ER
S
LEH150-Series pumps require a minimum application of 20 feet head.
Do not use pump in this area – use a smaller pump.
ATTENTION
For pressure sewer applications, verify a Redundant Check Valve Assembly (curb stop and check valve) is installed between the pump discharge and the street main, as close to the public right-of-way as possible, on all installations to protect from system pressures.
Copyright © Liberty Pumps, Inc. 2025 All rights reserved. Specifications subject to change without notice. LEH150_P2 R04/2025
7000 Apple Tree Avenue Bergen NY 14416 Phone 1-800-543-2550 Fax 1-585-494-1839 Email Liberty@LibertyPumps.com Web www.LibertyPumps.com
LEH150-Series Dimensional Data
17.4” [44.2 cm]
6” [15.2 cm]
12/3 POWER CORD 230 VOLT
(1-PHASE)
8.1” [20.6 cm]
12.9” [32.8 cm]
2” OR 3” NPT DISCHARGE
FLANGE OPTIONS
PIGGYBACK SWITCH
230 VOLT
1-PHASE
ONLY
Copyright © Liberty Pumps, Inc. 2025 All rights reserved. Specifications subject to change without notice. LEH150_P3 R04/2025
7000 Apple Tree Avenue Bergen NY 14416 Phone 1-800-543-2550 Fax 1-585-494-1839 Email Liberty@LibertyPumps.com Web www.LibertyPumps.com
LEH150-Series Electrical Data
MODEL HP VOLTAGE PHASE SF
FULL
LOAD
AMPS
LOCKED
ROTOR
AMPS
THERMAL
OVERLOAD
TEMP
STATOR
WINDING
CLASS
CORD
LENGTH
DISCHARGE AUTOMATIC
LEH152A2-2 1.5 208�230 1 1.00 15 53 135°C B 25� 2� FLANGED YES
LEH152A2-5-Y 1.5 208�230 1 1.00 15 53 135°C B 50� 2� FLANGED YES
LEH152M2-2 1.5 208�230 1 1.00 15 53 135°C B 25� 2� FLANGED NO
LEH152M2-3 1.5 208�230 1 1.00 15 53 135°C B 35� 2� FLANGED NO
LEH152M2-5 1.5 208�230 1 1.00 15 53 135°C B 50� 2� FLANGED NO
LEH152A3-2 1.5 208�230 1 1.00 15 53 135°C B 25� 3� FLANGED YES
LEH152A3-5-Y 1.5 208�230 1 1.00 15 53 135°C B 50� 3� FLANGED YES
LEH152M3-2 1.5 208�230 1 1.00 15 53 135°C B 25� 3� FLANGED NO
LEH152M3-3 1.5 208�230 1 1.00 15 53 135°C B 35� 3� FLANGED NO
LEH152M3-5 1.5 208�230 1 1.00 15 53 135°C B 50� 3� FLANGED NO
LEH153M2-2 1.5 208/230 3 1.00 11.4 61 N/A B 25� 2� FLANGED NO
LEH153M2-3 1.5 208/230 3 1.00 11.4 61 N/A B 35� 2� FLANGED NO
LEH153M2-5 1.5 208/230 3 1.00 11.4 61 N/A B 50� 2� FLANGED NO
LEH153M3-2 1.5 208/230 3 1.00 11.4 61 N/A B 25� 3� FLANGED NO
LEH153M3-3 1.5 208/230 3 1.00 11.4 61 N/A B 35� 3� FLANGED NO
LEH153M3-5 1.5 208/230 3 1.00 11.4 61 N/A B 50� 3� FLANGED NO
LEH154M2-2 1.5 440�480 3 1.00 5.7 31 N/A B 25� 2� FLANGED NO
LEH154M2-3 1.5 440�480 3 1.00 5.7 31 N/A B 35� 2� FLANGED NO
LEH154M2-5 1.5 440�480 3 1.00 5.7 31 N/A B 50� 2� FLANGED NO
LEH154M3-2 1.5 440�480 3 1.00 5.7 31 N/A B 25� 3� FLANGED NO
LEH154M3-3 1.5 440�480 3 1.00 5.7 31 N/A B 35� 3� FLANGED NO
Copyright © Liberty Pumps, Inc. 2025 All rights reserved. Specifications subject to change without notice. LEH150_P4 R04/2025
7000 Apple Tree Avenue Bergen NY 14416 Phone 1-800-543-2550 Fax 1-585-494-1839 Email Liberty@LibertyPumps.com Web www.LibertyPumps.com
LEH150-Series Control Panel Information
LEH154M3-5 1.5 440�480 3 1.00 5.7 31 N/A B 50� 3� FLANGED NO
LEH155M2-2 1.5 575 3 1.00 4.8 24 N/A B 25� 2� FLANGED NO
LEH155M2-3 1.5 575 3 1.00 4.8 24 N/A B 35� 2� FLANGED NO
LEH155M2-5 1.5 575 3 1.00 4.8 24 N/A B 50� 2� FLANGED NO
LEH155M3-2 1.5 575 3 1.00 4.8 24 N/A B 25� 3� FLANGED NO
LEH155M3-3 1.5 575 3 1.00 4.8 24 N/A B 35� 3� FLANGED NO
LEH155M3-5 1.5 575 3 1.00 4.8 24 N/A B 50� 3� FLANGED NO
PUMP
MODEL
SX-SERIES
3-FLOAT
NEMA 1
SX-SERIES
3-FLOAT
NEMA 4X
AE-SERIES
3-FLOAT
NEMA 1
AE-SERIES
4-FLOAT
NEMA 1
AE-SERIES
3-FLOAT
NEMA 4X
AE-SERIES
4-FLOAT
NEMA 4X
IPS-SERIES IPD-SERIES
SIMPLEX DUPLEX SIMPLEX DUPLEX
LEH152 SXH21=3 SXH24=3 AE21H=3 AE21H=4 AE24H=3 AE24H=4 IPS-24H IPD-24H
LEH153 � SX34=3-511 � � AE34=3-511 AE34=4-511 IPS-34-511 IPD-34-511
LEH154 � SX34=3-171 � � AE34=3-171 AE34=4-171 IPS-34-171 IPD-34-171
LEH155 � SX54=3-161 � � AE54=3-161 AE54=4-161 IPS-54-161 IPD-54-161
MODEL HP VOLTAGE PHASE SF
FULL
LOAD
AMPS
LOCKED
ROTOR
AMPS
THERMAL
OVERLOAD
TEMP
STATOR
WINDING
CLASS
CORD
LENGTH
DISCHARGE AUTOMATIC
Copyright © Liberty Pumps, Inc. 2025 All rights reserved. Specifications subject to change without notice. LEH150_P5 R04/2025
7000 Apple Tree Avenue Bergen NY 14416 Phone 1-800-543-2550 Fax 1-585-494-1839 Email Liberty@LibertyPumps.com Web www.LibertyPumps.com
LEH150-Series Technical Data
IMPELLER SEMI-OPEN 2 VANE, CLASS 25 CAST IRON
SOLIDS HANDLING 2�
PAINT POWDER COATING
MAX LIQUID TEMP
CONTINUOUS DUTY 40°C / 104°F
INTERMITTENT 60°C / 140°F
MAX STATOR TEMP 135°C / 275°F
THERMAL OVERLOAD (1-PHASE) 135°C / 275°F
POWER CORD TYPE
1-PHASE SJOOW
3-PHASE SEOOW
MOTOR HOUSING CLASS 25 CAST IRON
VOLUTE CLASS 25 CAST IRON
SHAFT STAINLESS
HARDWARE STAINLESS
O-RINGS BUNA-N
MECHANICAL SEAL CARBON CERAMIC
MIN BEARING LIFE 50,000 HRS
APPROX WEIGHT 93 LBS / 42 KG
CERTIFICATIONS SSPMA, cCSAus
Copyright © Liberty Pumps, Inc. 2025 All rights reserved. Specifications subject to change without notice. LEH150_P6 R04/2025
7000 Apple Tree Avenue Bergen NY 14416 Phone 1-800-543-2550 Fax 1-585-494-1839 Email Liberty@LibertyPumps.com Web www.LibertyPumps.com
LEH150-Series Specifications
1.01 GENERAL
The contractor shall provide labor, material, equipment, and incidentals required to provide __________ (QTY) centrifugal sewage pumps as specified herein. The pump models covered in this specification are LEH150-Series single or three-phase sewage pumps. The pump furnished for this application shall be model ___________________________________________ as manufactured by Liberty Pumps.
2.01 OPERATING CONDITIONS
Each submersible pump shall be rated at 1.5 hp ______________ volts, _________ phase, 60 Hz, 3450 RPM. The unit shall produce ___________ GPM at _______________ feet of total dynamic head.
The submersible pump shall be capable of handling 2� solids enabling pumping over long distances in pipelines as small as 2� in diameter.
The submersible pump shall have a shut-off head of 70 feet and a maximum flow of 200 GPM @ 20 feet of total dynamic head.
The pump shall be controlled with:
__ A piggyback style on/off float switch
__ A NEMA 4X simplex control panel with three float switches including a high water alarm
__ A NEMA 4X duplex control panel with three float switches including a high water alarm
3.01 CONSTRUCTION
Each centrifugal sewage pump shall be equal to the Certified LEH150-Series sewage pumps as manufactured by Liberty Pumps, Bergen NY. The castings shall be constructed of Class 25 cast iron. The motor housing shall be oil-filled to dissipate heat. Air-filled motors shall not be considered equal since they do not properly dissipate heat from the motor. All mating parts shall be machined and sealed with a Buna-N O-ring. All fasteners exposed to the liquid shall be stainless steel. The motor shall be protected on the top side with sealed cord entry plate with molded pins to conduct electricity eliminating the ability of water to enter internally through the cord. The motor shall be protected on the lower side with a dual seal arrangement. The first seal is a double lip seal molded in FKM fluoroelastomer or Buna-N. The second/main seal shall be a unitized graphite impregnated silicone carbide hard face seal with stainless steel housings and spring.
The upper and lower bearing shall be capable of handling all radial thrust loads. The lower bearing shall have the additional ability to handle the downward axial thrust produced by the impeller by design of angular contact roller races. The pump housing shall be of the concentric design thereby equalizing the pressure forces inside the housing which will extend the service life of the seals and bearings.
The pump shall be furnished with stainless steel handle having a nitrile grip.
4.01 ELECTRICAL POWER CORD
The submersible pump shall be supplied with length of multi-conductor power cord, as per Electrical Data table. It shall be cord type SJOOW (1-phase) or type SEOOW (3-phase), capable of continued exposure to the pumped liquid. The power cord shall be sized for the rated full load amps of the pump in accordance with the National Electric Code. The power cord shall not enter the motor housing directly but will conduct electricity to the motor by means of a water tight compression fitting cord plate assembly, with molded pins to conduct electricity. This will eliminate the ability of water to enter internally through the cord, by means of a damaged or wicking cord.
Copyright © Liberty Pumps, Inc. 2025 All rights reserved. Specifications subject to change without notice. LEH150_P7 R04/2025
7000 Apple Tree Avenue Bergen NY 14416 Phone 1-800-543-2550 Fax 1-585-494-1839 Email Liberty@LibertyPumps.com Web www.LibertyPumps.com
5.01 MOTORS
Single-phase motors shall be oil-filled, split-phase, capacitor start, Class B insulated NEMA B design, rated for continuous duty.
Three-phase motors shall be polyphase. At maximum load the winding temperature shall not exceed 135°C unsubmerged. Since air-filled motors are not capable of dissipating heat they shall not be considered equal. Single-phase motors shall have an integral thermal overload switch in the windings for protecting the motor. Three-phase motors shall be used with an appropriate controller with integral overload protection. The capacitor circuit on single-phase motors shall be mounted internally in the pump. Single-phase motors shall have an integral solid state starting circuit switch for switching the start winding off.
6.01 BEARINGS AND SHAFT
An upper radial and lower thrust bearing shall be required. The upper bearing shall be a single ball/race type bearing. The lower bearing shall be an angular contact heavy duty ball/race type bearing, designed to handle axial pump thrust loads. Both bearings shall be permanently lubricated by the oil, which fills the motor housing. The motor shaft shall be made of 300 or 400 series stainless steel and have a minimum diameter of 0.670".
7.01 SEALS
The pump shall have a dual seal arrangement consisting of a lower and upper seal to protect the motor from the pumping liquid. The lower seal shall be a FKM fluoroelastomer OR Buna-N molded double lip seal, designed to exclude foreign material away from the main upper seal. The upper seal shall be a unitized graphite impregnated silicon carbide seal with stainless steel housings and spring. The motor plate/housing interface shall be sealed with a Buna-N O-ring.
8.01 IMPELLER
The impeller shall be a Class 25 cast iron semi-open 2 vane impeller, with pump out vanes on the back shroud to keep debris away from the seal area. It shall be screw mounted to the motor shaft with a bonding agent and jam nut.
9.01 PRESSURE SEWER APPLICATIONS
A redundant check valve assembly consisting of a curb stop and check valve must be installed between the pump discharge and the street main, as close to the public right-of-way as possible, on all pressure (force main) sewer installations to protect from system pressures. The curb stop valve is necessary to isolate the site from the pressure sewer while the check valve provides redundant protection against potentially detrimental backflow. All valves and fittings should be rated for at least 200 PSI service. See Liberty Pumps line of CSV-Series Curb Stop/Swing Check Valve Assemblies and CK-Series Connection Kit.
10.01 CONTROLS
All single-phase units can be supplied with CSA and UL approved automatic wide-angle tilt float switches. The switches shall be equipped with piggyback style plug that allows the pump to be operated manually without the removal of the pump in the event that a switch becomes inoperable. Manual pumps are operable by means of a pump control panel.
11.01 PAINT
The exterior of the casting shall be protected with powder coat or polyester paint.
12.01 SUPPORT
The pump shall have cast iron support legs enabling it to be a freestanding unit. The legs will be high enough to allow 2� solids handling.
Copyright © Liberty Pumps, Inc. 2025 All rights reserved. Specifications subject to change without notice. LEH150_P8 R04/2025
7000 Apple Tree Avenue Bergen NY 14416 Phone 1-800-543-2550 Fax 1-585-494-1839 Email Liberty@LibertyPumps.com Web www.LibertyPumps.com
13.01 SERVICEABILITY
Components required for the repair of the pump shall be shipped within a period of 24 hours.
14.01 FACTORY ASSEMBLED TANK SYSTEMS WITH GUIDE RAIL AND QUICK DISCONNECT DISCHARGE
__ Guide factory mounted rail system with pump suspended by means of thread-on quick disconnect which is sealed by means of nitrile grommets or O-rings. The discharge piping shall be Schedule 80 PVC and furnished with a check valve and PVC shut-off ball valve. The tank shall be wound fiberglass or roto-molded plastic. A cast iron or fiberglass inlet hub shall be provided with the fiberglass systems.
__ Stainless steel guide rail
__ Zinc plated steel guide rail
__ Diameter of basin in inches
__ Height of basin in inches
__ Distance from top of tank to discharge pipe outlet in inches
__ Fiberglass cover
__ Structural foam polymer cover
__ Steel cover
__ Simplex system with outdoor panel and alarm
__ Duplex system with outdoor panel and alarm
__ Separate outdoor alarm
__ Remote outdoor alarm
15.01 TESTING
The pump shall have a ground continuity check and the motor chamber shall be Hi-potted to test for electrical integrity, moisture content and insulation defects. The motor and volute housing shall be pressurized, and an air leak decay test is performed to ensure integrity of the motor housing. The pump shall be run at rated voltage to verify current, performance curve and monitor operation.
16.01 QUALITY CONTROL
The pump shall be manufactured in an ISO 9001 certified facility.
17.01 WARRANTY
Standard limited warranty shall be 3 years.