First Article Inspection Report Form 1: Characteristic Accountability, Verification and Compatibility Evaluation
1. Part Number
N-WMT04X50802001606-00 AKMA or Equivalent Constructed Enclosure
2. Part Name
Enclosure, With-Out Back Panel & Studs, NEMA 4X, Wall Mount, 5086-H32 Aluminum, .80 Thick, 20" H x 16" Width x 6" Depth
3. Serial/Lot Number
N/A
4. FAI Report
FAI-001
Characteristic Accountability Inspection / Test Results Other Fields (Insert columns, as required by organization or customer.
5. Char No.
6. Reference Location 7. Characteristic Designator (Critical, Key)
8.
Requirement
(Dimension, Performance)
8a. UoM 8b.
Upper Limit
8c.
Lower Limit
9. Results (e.g. Pass/1.4 in.
or Failed/1.5 in.
10. Designed Tooling
11. Non- Conformance Number
14. Inspect Device
15. Notes
PC # 1 RFP Attachment 3, Enclosure Requirement – Detailed Drawing, Page 1
Critical 20” Height Inches 0 0 N/A Tape Measure Horizontal measurement of overall exterior enclosure height, top view. Piece # 1 - Enclosure, PC # 1 RFP Attachment 3, Enclosure Requirement – Detailed Drawing, Page 3
Critical 16” Width Inches 0 0 N/A Tape Measure Vertical measurement of overall exterior enclosure width, side view. Piece # 1 - Enclosure.
PC # 1 RFP Attachment 3, Enclosure Requirement – Detailed Drawing, Page 3
Critical 6” Depth
Inches 0 0 N/A Tape Measure Horizontal measure of overall exterior enclosure depth. Piece # 1 - Enclosure.
PC # 2 RFP Attachment 3, Enclosure Requirement – Detailed Drawing, Page 4 and Page 11
Critical 11” Centered Inches 0 0 N/A Calipers/Tape Vertical measurement of 4 exterior aluminum weld pad placements for enclosure mounting.
Piece # 2 – Weld Pad Tap, 3/8”-16 Tap, ¾” DIA x 1-1/2 L.
PC # 2 RFP Attachment 3, Enclosure Requirement – Detailed Drawing, Page 1 and Page 11
Critical 14.625” Centered Inches 0 0 N/A Calipers Horizontal measurement of 4 exterior aluminum weld pad placements for enclosure mounting.
Piece 2 – Weld Pad Tap, 3/8”-16 Tap, ¾” DIA x 1-1/2 L.
PC # 2 RFP Attachment 3, Enclosure Requirement – Detailed Drawing, Page 11
Critical 2.5” Centered
Inches 0 0 N/A Calipers/Tape Vertical measurement of exterior aluminum welds pad placements to top-bottom side wall;
Piece # 2 – Weld Pad Tap, 3/8” – 16 Tap, ¾” DIA x 1-1/2 L.
PC # 2 RFP Attachment 3, Enclosure Requirement – Detailed Drawing, Page 1 and Page 11
Critical 2.6875” Centered Inches 0 0 N/A Calipers Horizontal measurement of exterior aluminum weld pad placements to right-left side wall;
Piece # 2 – Weld Pad Tap, 3/8” – 16 Tap, ¾” DIA x 1-1/2 L.
PC#23 RFP Attachment 3, Enclosure Requirement – Detailed Drawing, Page 10
Key 3” W ide Inches 0 0 N/A Tape Measure Horizontal measurement of overall width of aluminum plate. Piece # 23.
PC#23 RFP Attachment 3, Enclosure Requirement – Detailed Drawing, Page 10
Key 3” Length Inches 0 0 N/A Tape Measure Vertical measurement of overall length of aluminum plate. Piece #23.
PC#23 RFP Attachment 3, Enclosure Requirement – Detailed Drawing, Page 10
Key 1/4 ” Thick Inches 0 0 N/A Tape Measure Thickness measurement of aluminum plate, Piece # 23.
A USCG customer signature and acceptance indicates that all first article characteristics demonstrate the requirements for enclosure full-rate production.
12. Prepared By: 13. Date
14. Report Reviewed by (Quality Representative):
15. Date
16. Customer Approval and Stamp (if applicable):
17. Date
FAI Status:
FAI Acceptable FAI Pending FAI Rejected