This solicitation requests quotations for downdraft tables to be used by the United States Coast Guard. The Coast Guard seeks to procure downdraft tables that meet technical specifications including a minimum four by six foot work surface, 150-250 feet per minute average airflow, HEPA filtration, and other features. Quotations are due by August 19th, with an anticipated award date of September 3rd. This is a 100% small business set-aside solicitation to be awarded on a brand name or equal basis.
The document also provides information on filing agency protests with the Coast Guard Ombudsman Program as an alternative to protests with the Government Accountability Office or in other external forums. Interested parties are encouraged to first seek informal resolution with the Contracting Officer, then file a formal agency protest with either the Contracting Officer or Ombudsman, with the goal of resolving protests within 35 days of filing.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 4-Instructions.pdf | ||
| Responses to Questions.pdf | ||
| 2 - Schedule of Supplies.xls | XLS spreadsheet | |
| 70Z03820QE0000075.pdf | ||
| Technical Specifications.xls | XLS spreadsheet |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Technical Worksheet
| OFFEROR: _____________________________________ | ||
| Cage Code: ________________________________________ | ||
| Technical Criteria | Does the offeror Meet requirement? | Comments |
| Are you proving a quotation for the brand name part number? If yes, you can stop here. If no, please continue to complete the remainder of the form. | ||
| For Alternate Parts Only: | ||
| Provide the Manufacturer and Part number of the quoted item: | ||
| Completely self-contained unit | ||
| Must have backdraft and downdraft contaminant capture | ||
| Downdraft tables must be built to fit within the door dimensions listed in the table on the next page | ||
| Power controls must be customizable to accommodate shop layout | ||
| Evenly ventilated working surface area with 6,000 CFM airflow rating | ||
| Adequate work space illumination must be provided by sealed light emitting diode (LED) | ||
| Minimum table work space must be four (4) feet deep and six (6) feet wide and no larger than seven (7) feet deep, eight (8) feet wide and nine (9) feet six (6) inches height | ||
| Equipped with a manometer to determine filter impaction and service life | ||
| Manometer must be installed in a conspicuous location for technician monitoring | ||
| Minimum average airflow requirement of 150 to 250 FPM to ensure adequate capture of Hexavalent Chromium (CrVI) and other hazardous dust generating from sanding | ||
| Equipped with High-Efficiency Particulate Air (HEPA) rated filters with a minimum filtration efficiency of 99.7 percent of airborne particles meauring 0.3 micron in diameter or better | ||
| Engineered to automatically self-clean filter bank to prolong service life | ||
| Blower motor compartment must be lined with sound dampening material to reduce noise levels during useage | ||
| Must be equipped with a motor hours meter | ||
| Items to be Included at no charge with the units: | ||
| Operator training | ||
| Standard Warranty - Please include warranty information | ||
| * Table delineating door size | ||
| 83" x 34" | 94" x 70" | |
| single door | double door | |
| ASTORIA | x | |
| ATLANTIC CITY | x | |
| BARBERS POINT | x | |
| BORINQUEN | x | |
| CAPE COD | x | |
| CLEARWATER | x | |
| CORPUS CHRISTI | x | |
| DETROIT | x | |
| ELIZABETH CITY | x | |
| HITRON | x | |
| HOUSTON | x | |
| HUMBOLDT BAY | x | |
| KODIAK | x | |
| MIAMI | x | |
| MOBILE | x | |
| NEW ORLEANS | x | |
| NORTH BEND | x | |
| PORT ANGELES | x | |
| SACRAMENTO | x | |
| SAN DIEGO | x | |
| SAN FRANCISCO | x | |
| SAVANNA | x | |
| SITKA | x |
&C&"-,Bold"&12Technical Criteria 70Z03820QE0000075 This Document is Source Selection Sensitive Information IAW FAR 2.101 and 3.104 &C&"Times New Roman,Regular"&12Page &P of 27
File details come from the government source that posted it. Updated .