2ND FLOOR LIFE SAFETY PLAN A32L02001G103-G103.pdf

PDF 425 KB Posted

Attached to
USCG BASE NEW ORLEANS (FLOORING REPLACEMENT)
Solicitation number
70Z02925QNEWO0186
Issued by

About this file

This document is a Second Floor Life Safety Plan architectural drawing for a U.S. Coast Guard facilities reconstruction project located in New Orleans, Louisiana. The detailed floor plan shows a complex layout with multiple rooms, each annotated with specific square footage measurements, and includes critical safety information such as exit capacities and distances. Key technical details include stair and door exit capacities calculated using both NFPA and IBC standards, with exit capacities ranging from 170 to 280 people depending on the calculation method. The second floor occupancy load is noted as 343 people, and the plan includes specifications for fire-rated partitions, illuminated exit signs, fire extinguishers, and references to additional code data on another sheet. The drawing is part of an as-built documentation set for the reconstruction of a USCG facility, prepared by LANT (likely referring to Coast Guard Atlantic Area) and dated 4/10/10.

View the file

Other files

File Type Posted
updated Statement of work.pdf PDF
1ST FLOOR LIFE SAFETY PLAN A32L02001G102-G102.pdf PDF
WAGE RATE.txt TXT text file
Admin Building Flooring_SOW.docx DOCX document
Commercial Supplies Services Clauses Provisions FAC 2023-01.doc DOC document
SF-1449.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

260 SQ. FT. 245 SQ. FT. 245 SQ. FT. 245 SQ. FT. 245 SQ. FT. 241 SQ. FT. 245 SQ. FT. 244 SQ. FT. 245 SQ. FT. 244 SQ. FT. 269 SQ. FT.

392 SQ. FT.

270 SQ. FT. 274 SQ. FT.

SQ. FT.

392 SQ. FT.

1019 SQ. FT.

43 SQ. FT.

SQ. FT.

259 SQ. FT. 264 SQ. FT.274 SQ. FT.

204 SQ. FT.

175 SQ. FT.

75 SQ. FT.

30 SQ. FT.

392 SQ. FT.

2377 SQ. FT.

109 SQ. FT.

109 SQ. FT.

109 SQ. FT.

115 SQ. FT.

96 SQ. FT.

SQ. FT.

148 SQ. FT. 280 SQ. FT.

280 SQ. FT.

147 SQ. FT. 318 SQ. FT.

105 SQ. FT.

143 SQ. FT.

105 SQ. FT.

1235 SQ. FT.

24 SQ. FT.

1172 SQ. FT.

1994 SQ. FT.

109 SQ. FT. 111 SQ. FT. 120 SQ. FT.

1044 SQ. FT.

402 SQ. FT.

138 SQ. FT. 135 SQ. FT. 251 SQ. FT. 163 SQ. FT. 96 SQ. FT.

2402 SQ. FT.

113 SQ. FT.108 SQ. FT.91 SQ. FT.115 SQ. FT.113 SQ. FT.161 SQ. FT.106 SQ. FT.159 SQ. FT.159 SQ. FT.106 SQ. FT.313 SQ. FT.163 SQ. FT.253 SQ. FT. 106 SQ. FT. 106 SQ. FT. 113 SQ. FT.

609 SQ. FT.

108 SQ. FT.

702 SQ. FT.

629 SQ. FT.300 SQ. FT.

1952 SQ. FT.

189 SQ. FT.189 SQ. FT.

276 SQ. FT.

575 SQ. FT.

57 SQ. FT.

1807 SQ. FT.

S

Q

F

T

31 SQ. FT.

1153 SQ. FT.

71 SQ. FT.

SQ. FT.

TRAVEL DISTANCE 143'-0"

EXIT DISTANCE 190'-0"

EXIT DISTANCE 204'-6"

T R

A V

E L

D

I S

T A

N C

E

TRAVEL DISTANCE 92'-0"

EXIT DISTANCE 178'-0"

EXIT DISTANCE 221'-0"

NFPA

STAIR EXIT CAPACITY

53/.3= 176 PEOPLE

IBC

STAIR EXIT CAPACITY

53/.2= 265 PEOPLE

NFPA

STAIR EXIT CAPACITY

56/.3= 186 PEOPLE

IBC

STAIR EXIT CAPACITY

56/.2= 280 PEOPLE

REQ'D. EXIT CAPACITY

24 PEOPLE

IBC

DOOR EXIT CAPACITY

34/.2 = 170 PEOPLE

NFPA

DOOR EXIT CAPACITY

34/.15 = 226 PEOPLE

NFPA

STAIR EXIT CAPACITY

53/.3= 176 PEOPLE

IBC

STAIR EXIT CAPACITY

53/.2= 265 PEOPLE

IBC

DOOR EXIT CAPACITY

34/.2 = 170 PEOPLE

NFPA

DOOR EXIT CAPACITY

34/.15 = 226 PEOPLE

IBC

DOOR EXIT CAPACITY

34/.2 = 170 PEOPLE

NFPA

DOOR EXIT CAPACITY

34/.15 = 226 PEOPLE

NFPA

STAIR EXIT CAPACITY

56/.3= 186 PEOPLE

IBC

STAIR EXIT CAPACITY

56/.2 = 280 PEOPLE

IBC

DOOR EXIT CAPACITY

34/.2 = 170 PEOPLE

NFPA

IBC

DOOR EXIT CAPACITY

34/.15 = 226 PEOPLE

REQ'D. EXIT CAPACITY

148 PEOPLE

REQ'D. EXIT CAPACITY

147 PEOPLE

REQ'D. EXIT CAPACITY

24 PEOPLE

SECOND FLOOR OCCUPANY LOAD: 343

REFER TO SHEET G101 FOR ADDITIONAL CODE DATA

1 HR. RATED PARTITION

ILLUMINATED EXIT SIGN

RE: SPECIAL SYSTEMS PLAN

F.E.

FIRE EXTINGUISHER

PER CODE

1/2 HR. RATED PARTITION

30 SQ. FT.