About this file

This document is an Amendment of Solicitation/Modification of Contract for a federal security camera upgrade project at the William Kenzo Nakamura Courthouse in Seattle, Washington. The amendment (Number 0003) adds Appendix A and Appendix B to the original solicitation, detailing specific camera replacement and installation requirements across multiple locations including the main entrance, garage, sally port, and various exterior camera poles.

The scope involves replacing existing cameras with upgraded models, including 4K PTZ cameras with built-in infrared, 20 MP multi-sensor cameras, and 8 MP fixed exterior cameras. Additional work includes modifying camera pole positions, installing a new panoramic camera in an exterior tunnel, and setting up viewing stations on multiple floors with workstations, monitors, keyboards, and mice. The project also requires removing an existing coat rack and installing a new 32-inch monitor in the parking garage. The amendment specifies technical details for camera placement, mounting requirements, and integration with existing infrastructure, with an effective date of 09/22/2025 and response deadline of 09/24/2025 at 1000 PST.

View the file

Other files

File Type Posted
70RFPW25QWA000008 Q and A.pdf PDF
70RFPW25QWA000008 attendee list.pdf PDF
RFQ 70RFPW25QWA000008 AM0002.pdf PDF
70RFPW25QWA000008 (19).pdf PDF
70RFPW25QWA000008 0807 R1.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

09/22/2025

Door

6th Avenue

Spring Street

Madison Avenue

5th Avenue

6th Ave. Screening Workstation

2nd Floor

Existing Cameras On Pole

Existing Cameras On Pole

Existing Cameras On Pole

Existing Cameras on Pole

Existing Sally Port Camera

Existing main entrance camera

70RFPW25QWA000008 AM0003 APPENDIX A Page 3 of 20

Garage Parking

2'x2' Junction Panel

Existing Camera at Garage Entrance

Existing Cameras on pole above Garage Entrance

70RFPW25QWA000008 AM0003 APPENDIX A Page 4 of 20 b

C

C

C

C

C

Spring St.

Madison St.Salley Port Replace existing Camera with Multi -sensor

JP East

JP

New Monitor

UPS

Workstation/ Server

Keyboard

Walkway to tunnel and sidewalk

Down to Garage Parking

C

C

Replace Existing Camera with Camera

Panoramic Camera for Tunnel

6th Avenue

5th Avenue

70RFPW25QWA000008 AM0003 APPENDIX A Page 5 of 20

70RFPW25QWA000008 AM0003 APPENDIX B Page 6 of 20

70RFPW25QWA000008 AM0003 APPENDIX B Page 7 of 20

70RFPW25QWA000008 AM0003 APPENDIX B Page 8 of 20

70RFPW25QWA000008 AM0003 APPENDIX B Page 9 of 20

70RFPW25QWA000008 AM0003 APPENDIX B Page 10 of 20

70RFPW25QWA000008 AM0003 APPENDIX B Page 11 of 20

70RFPW25QWA000008 AM0003 APPENDIX B Page 12 of 20

70RFPW25QWA000008 AM0003 APPENDIX B Page 13 of 20

70RFPW25QWA000008 AM0003 APPENDIX B Page 14 of 20

Install a panoramic camera to view inside of the exterior tunnel. The camera must be flush mounted to the concrete lid. The Contractor is responsible for any necessary trenching.

The contractor shall core through the roof of the tunnel and provide waterproof conduit from the penetration in the lid back directly to the nearest pole to utilize the existing raceway to inside the building. No boxes shall be used in the landscaping. The conduit shall be waterproof. Contractor to patch any trenched area with likewise material. The Contractor to include all trenching and conduit costs on a separate line item with their proposal. The Contractor is to also include all patching of trenched area (include type of material used) on a separate line item with their proposal. Prior to do any trenching (digging) the Contractor will coordinate the FPS PM and GSA Property Manager.

Contractor shall include with their proposal a diagram and explanation on how they plan to seal the penetration to the concrete lid to prevent leaks to the roof and/or from water getting inside the camera.

70RFPW25QWA000008 AM0003 APPENDIX B Page 15 of 20

70RFPW25QWA000008 AM0003 APPENDIX B Page 16 of 20

70RFPW25QWA000008 AM0003 APPENDIX B Page 17 of 20

70RFPW25QWA000008 AM0003 APPENDIX B Page 18 of 20

70RFPW25QWA000008 AM0003 APPENDIX B Page 19 of 20

70RFPW25QWA000008 AM0003 APPENDIX B Page 20 of 20

70RFPW25QWA000008 AM0003
Appendix A and B

File details come from the government source that posted it. Updated .