70B03C27R00000003_Attachment 8- NII(MEP_LEP)IDIQ Pricing Template_ (MEP_LEP)_ DRAFT RFP.xlsx
XLSX spreadsheet 98 KB Posted
- Solicitation number
- 70B03C27R00000003
About this file
This is a pricing template (Attachment 8) for an Indefinite Delivery, Indefinite Quantity (IDIQ) contract to establish multiple-award agreements for Large-Scale Fixed Systems, specifically Multi-Energy Portal (MEP) and Low-Energy Portal (LEP) systems for the Department of Homeland Security, U.S. Customs and Border Protection. The contract encompasses a base year plus four option years. The template requires contractors to submit detailed pricing for all Contract Line Item Numbers (CLINs) organized by category: Equipment (MEP or LEP systems with peripheral components), Site Design (program management, travel, and design phases), Civil Works (mobilization, command center construction, earth work, electrical/plumbing/mechanical installation, concrete work, and traffic control), Furniture, Fixtures, and Equipment (analyst and operator stations, power supplies, transformers), Installation (mechanical, electrical, plumbing, system integration), Training, Preventative and Corrective Maintenance, Warranty periods (1-5 years), On-Demand Services, and Indirect Rates. Key assumptions include installation in Southern California with a six-month project completion timeline; the MEP is designated as a two-lane new installation while the LEP is a three-lane new installation. Contractors must not alter quantities in blue-shaded cells and should complete separate pricing tabs for MEP and LEP systems. The template requires contractors to provide justification for proposed pricing and document all assumptions made during proposal development. Currently, only the Furniture and Fixtures CLIN (X403) contains sample populated values ($100,000-$121,550.63 across periods); all other CLINs display zero values, indicating the template is in draft form awaiting contractor completion. Submission requires all calculations to be accurate with functional formulas, and proposals submitted without this attachment completed in full may be deemed non-compliant.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Table 1 Summary (2)
| Contractor Name: | Summary Table | |
| Solicitation Number: | ||
| Task Order Number: | ||
| Task Order Title: | ||
| Base Period: | ||
| Option 1: | ||
| Option 2: | ||
| Option 3: | ||
| Option 4: | ||
| Option 5: |
| Contract Value | ||||||||
| Description | Total Price Base | Total Price Option 1 | Total Price Option 2 | Total Price Option 3 | Total Price Option 4 | 52.217-8 Extension | Total Price | |
| EQUIPMENT - Multi Energy Portal (MEP) | ||||||||
| CLIN 001 MEP | $ - 0 | $ - 0 | ||||||
| CLIN 101 Command Center | ERROR:#REF! | |||||||
| CLIN 201 Blanking Wall | ERROR:#REF! | |||||||
| CLIN 301 Power Conditioner | ERROR:#REF! | |||||||
| CLIN 401 | ERROR:#REF! | |||||||
| CLIN 501 | ERROR:#REF! | ERROR:#REF! | ||||||
| STANDARD LABOR | ||||||||
| CLIN 002 Engineering | ERROR:#REF! | |||||||
| CLIN 102 Technical Trade | ERROR:#REF! | |||||||
| CLIN 202 Laborers | ERROR:#REF! | |||||||
| CLIN 302 MEP | ERROR:#REF! | |||||||
| CLIN 402 Architecture | ERROR:#REF! | |||||||
| CLIN 502 Systems Designer | ERROR:#REF! | ERROR:#REF! | ||||||
| GENERAL REQUIREMENTS | ||||||||
| CLIN 003 Design | $ - 0 | |||||||
| CLIN 103 Civil | $ - 0 | |||||||
| CLIN 203 Site | $ - 0 | |||||||
| CLIN 303 Systems | $ - 0 | |||||||
| CLIN 403 Structure | $ - 0 | |||||||
| CLIN 503 Infrastructure | $ - 0 | $ - 0 | ||||||
| TRAINING | ||||||||
| CLIN 004 Analyst | $ 156,481.00 | |||||||
| CLIN 104 Training for Trainers | $ - 0 | |||||||
| CLIN 204 Operators | $ - 0 | |||||||
| CLIN 304 | $ - 0 | |||||||
| CLIN 404 | $ - 0 | |||||||
| CLIN 504 | $ - 0 | $ 156,481.00 | ||||||
| TESTING | ||||||||
| CLIN 005 Commissioning | $ 3,542,353.00 | |||||||
| CLIN 105 SAT | $ - 0 | |||||||
| CLIN 205 FAT | $ - 0 | |||||||
| CLIN 305 Systems | $ - 0 | |||||||
| CLIN 405 | $ - 0 | |||||||
| CLIN 505 | $ - 0 | $ 3,542,353.00 | ||||||
| DESIGN | ||||||||
| CLIN 006 Site Design | $ 263,164.00 | |||||||
| CLIN 106 Systems Design | $ - 0 | |||||||
| CLIN 206 Security | $ - 0 | |||||||
| CLIN 306 OIT | $ - 0 | |||||||
| CLIN 406 Blanking | $ - 0 | |||||||
| CLIN 506 Infrastructure | $ - 0 | $ 263,164.00 | ||||||
| CIVIL WORKS | ||||||||
| CLIN 007 Site Prep | $ 8,858,355.00 | |||||||
| CLIN 107 Concrete work | $ - 0 | |||||||
| CLIN 207 Steel Work | $ - 0 | |||||||
| CLIN 307 Geotech Studies | $ - 0 | |||||||
| CLIN 308 Infrastructure Install | $ - 0 | |||||||
| CLIN 407 Site Grading | $ - 0 | |||||||
| CLIN 507 Saw Cutting | $ - 0 | $ 8,858,355.00 | ||||||
| INSTALLATION | ||||||||
| CLIN 008 Mechanical | $ - 0 | |||||||
| CLIN 108 Electrical | $ - 0 | |||||||
| CLIN 208 Plumbing | $ - 0 | |||||||
| CLIN 308 Foundations | $ - 0 | |||||||
| CLIN 308 Command Center | $ - 0 | |||||||
| CLIN 408 Technology Trenches | $ - 0 | |||||||
| CLIN 508 Conduit/Junction Boxes | $ - 0 | $ - 0 | ||||||
| Grand Total | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |
| Check | ||||||||
| ERROR:#REF! |
&1#&"Times New Roman"&10&K000000SENSITIVE BUT UNCLASSIFIED
Table 1 Summary
| Contractor Name: | Summary Table | |
| Solicitation Number: | ||
| Task Order Number: | ||
| Task Order Title: | ||
| Base Period: | ||
| Option 1: | ||
| Option 2: | ||
| Option 3: | ||
| Option 4: | ||
| Option 5: |
| Contract Value | ||||||||
| Description | Total Price Base | Total Price Option 1 | Total Price Option 2 | Total Price Option 3 | Total Price Option 4 | 52.217-8 Extension | Total Price | |
| EQUIPMENT - Low Energy Portal (LEP) | ||||||||
| CLIN 101 LEP | $ - 0 | $ - 0 | ||||||
| CLIN 101 Command Center | ERROR:#REF! | |||||||
| CLIN 201 Blanking Wall | ERROR:#REF! | |||||||
| CLIN 301 Power Conditioner | ERROR:#REF! | |||||||
| CLIN 401 | ERROR:#REF! | |||||||
| CLIN 501 | ERROR:#REF! | ERROR:#REF! | ||||||
| STANDARD LABOR | ||||||||
| CLIN 002 Engineering | ERROR:#REF! | |||||||
| CLIN 102 Technical Trade | ERROR:#REF! | |||||||
| CLIN 202 Laborers | ERROR:#REF! | |||||||
| CLIN 302 Systems Design | ERROR:#REF! | |||||||
| CLIN 402 Architecture | ERROR:#REF! | |||||||
| CLIN 502 MEP | ERROR:#REF! | ERROR:#REF! | ||||||
| GENERAL REQUIREMENTS | ||||||||
| CLIN 003 Design | $ - 0 | |||||||
| CLIN 103 Civil | $ - 0 | |||||||
| CLIN 203 Site | $ - 0 | |||||||
| CLIN 303 Systems | $ - 0 | |||||||
| CLIN 403 Structure | $ - 0 | |||||||
| CLIN 503 Infrastructure | $ - 0 | $ - 0 | ||||||
| TRAINING | ||||||||
| CLIN 004 Analyst | $ 156,481.00 | |||||||
| CLIN 104 Training for Trainers | $ - 0 | |||||||
| CLIN 204 Operators | $ - 0 | |||||||
| CLIN 304 | $ - 0 | |||||||
| CLIN 404 | $ - 0 | |||||||
| CLIN 504 | $ - 0 | $ 156,481.00 | ||||||
| TESTING | ||||||||
| CLIN 005 Commissioning | $ 3,542,353.00 | |||||||
| CLIN 105 SAT | $ - 0 | |||||||
| CLIN 205 FAT | $ - 0 | |||||||
| CLIN 305 Systems | $ - 0 | |||||||
| CLIN 405 | $ - 0 | |||||||
| CLIN 505 | $ - 0 | $ 3,542,353.00 | ||||||
| DESIGN | ||||||||
| CLIN 006 Site Design | $ 263,164.00 | |||||||
| CLIN 106 Systems Design | $ - 0 | |||||||
| CLIN 206 Security | $ - 0 | |||||||
| CLIN 306 OIT | $ - 0 | |||||||
| CLIN 406 Blanking | $ - 0 | |||||||
| CLIN 506 Infrastructure | $ - 0 | $ 263,164.00 | ||||||
| CIVIL WORKS | ||||||||
| CLIN 007 Site Prep | $ 8,858,355.00 | |||||||
| CLIN 107 Concrete work | $ - 0 | |||||||
| CLIN 207 Steel Work | $ - 0 | |||||||
| CLIN 307 Geotech Studies | $ - 0 | |||||||
| CLIN 308 Infrastructure Install | $ - 0 | |||||||
| CLIN 407 Site Grading | ||||||||
| CLIN 507 Saw Cutting | $ - 0 | $ 8,858,355.00 | ||||||
| INSTALLATION | ||||||||
| CLIN 008 Mechanical | $ - 0 | |||||||
| CLIN 108 Electrical | $ - 0 | |||||||
| CLIN 208 Plumbing | ||||||||
| CLIN 308 Foundations | $ - 0 | |||||||
| CLIN 308 Command Center | $ - 0 | |||||||
| CLIN 408 Technology Trenches | $ - 0 | |||||||
| CLIN 508 Conduit/Junction Boxes | $ - 0 | $ - 0 | ||||||
| Grand Total | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | ERROR:#REF! | |
| Check | ||||||||
| ERROR:#REF! |
&1#&"Times New Roman"&10&K000000SENSITIVE BUT UNCLASSIFIED
Instructions Attachment 8 serves as the standardized format for submitting pricing information and associated details for all required Contract Line Item Numbers (CLINs). This ensures uniformity across proposals and facilitates efficient evaluation of submissions.
1. Required Information Contractors shall complete the following sections of Attachment 8:
a. Pricing Table: Provide detailed pricing for all required CLINs as specified in the solicitation. Ensure that all costs are clearly itemized and align with the scope of work and technical requirements outlined in the Statement of Work (SOW).
I. You will notice there are several sub-CLINs under the main CLIN structure. CBP will factor the estimates included in the sub-CLINs into the main CLIN. Vendors will not be limited due to these sub-SLINs, however, the intent is to make sure all aspect of these CLINs are being considered, estimated, and proposed to. If vendors feel some of the sub-CLINs should not be proposed to, then refrain from providing an estimate. If vendors feel like a sub-CLIN is missing from consideration, please add the additional sub-CLIN and provide an estimate.
II. The Civil Works sub-CLINs will be evaluated based on the provided cost elements at the provided quantities. Please assume the following when completing the CLIN price proposal:
* The installation site is in Southern California
* The MEP is a 2 lane new installation project while the LEP is a 3 lane new installation project
* Do not change quantities provided. Cells highlighted in blue are locked and calculated using cells below.
* The project is to be completed in 6 months
* Please refer to the notes included in column B for additional details
Note: Furniture and Fixtures is a fixed budetary line for items needed unknown at the time of proposal. This can include, but not limited to, additional tables, chairs, light fixtures, refridgerators, etcetera.
b. Justification Tab: Use this tab to provide a detailed explanation of the proposed pricing. Include any supporting rationale, such as cost breakdowns, market research, or other relevant data that substantiates the proposed costs.
c. Assumptions Tab: Clearly outline any assumptions made during the development of the proposal. These may include technical, operational, or logistical considerations that impact pricing or performance.
2. Formatting Requirements All entries in Attachment 8 must be completed electronically using the provided template. Do not alter the structure or format of the pricing table or tabs. If additional information is necessary, include it as supplemental documentation and reference it in the justification tab. Ensure all calculations are accurate and formulas within the pricing table are functional.
3. Submission Guidelines Proposals must be submitted in accordance with the timeline and instructions provided in the solicitation.
Ensure Attachment 8 is included as part of the proposal package. Proposals submitted without Attachment 8 completed in full may be deemed non-compliant and excluded from consideration.
5. Evaluation Considerations Proposals will be evaluated based on the accuracy, completeness, and reasonableness of the pricing provided in Attachment 8, as well as the clarity and validity of the justification and assumptions. Contractors are encouraged to provide detailed and transparent information to facilitate the evaluation process.
6. Questions and Clarifications If contractors have questions regarding the use of Attachment 8 or require clarification on any aspect of the pricing table template, they should submit inquiries in writing to the Contracting Officer prior to the proposal Question and Answer deadline.
MEP CLINs1
| Contractor Name: | |||||||||||||||||
| Solicitation Number: | |||||||||||||||||
| Task Order Number: | |||||||||||||||||
| Task Order Title: | |||||||||||||||||
| * The installation site is in Southern California | |||||||||||||||||
| * The MEP is a 2 lane new installation project. | |||||||||||||||||
| * Don't change the provided quantities in the blue shaded cells | |||||||||||||||||
| * The project is to be completed in 6 months | |||||||||||||||||
| * Please refer to the notes included in column B for additional details | |||||||||||||||||
| Base Year | Ordering Period 1 | Ordering Period 2 | Ordering Period 3 | Ordering Period 4 | |||||||||||||
| EQUIPMENT - MULTI-ENERGY PORTAL SYSTEM (FFP) | CLIN 010 | CLIN 110 | CLIN 210 | CLIN 310 | CLIN 410 | ||||||||||||
| Sub-CLIN | Description | Qty | Rate | Amount | Qty | Rate | Amount | Qty | Rate | Amount | Qty | Rate | Amount | Qty | Rate | Amount | Total |
| X100 | MEP System | 2 | $0.00 | 2 | $0.00 | 2 | $0.00 | 2 | $0.00 | $0.00 | 2 | $0.00 | $0.00 | ||||
| X104 | UVBx | 2 | $0.00 | 2 | $0.00 | 2 | $0.00 | 2 | $0.00 | $0.00 | 2 | $0.00 | $0.00 | ||||
| X105 | Peripheral Sensors | $0.00 | $0.00 | $0.00 | $0.00 | $0.00 | $0.00 | $0.00 |
Total Equipment Management $0.00 Total Equipment Management $0.00 Total Equipment Management $0.00 Total Equipment Management $0.00 Total Equipment Management $0.00 $0.00
| Base Year | Ordering Period 1 | Ordering Period 2 | Ordering Period 3 | Ordering Period 4 | |||||||||||||
| SITE DESIGN (FFP) | CLIN 020 | CLIN 120 | CLIN 220 | CLIN 320 | CLIN 420 | ||||||||||||
| Sub-CLIN | Description | Qty | Rate | Amount | Qty | Rate | Amount | Qty | Rate | Amount | Qty | Rate | Amount | Qty | Rate | Amount | Total |
| X200 | Program Management and Operations Labor- Fully Burdened | 1 | $0.00 | 1 | $0.00 | 1 | $0.00 | $0.00 | 1 | $0.00 | 1 | $0.00 | $0.00 | ||||
| X201 | Travel | 1 | $0.00 | 1 | $0.00 | 1 | $0.00 | $0.00 | 1 | $0.00 | 1 | $0.00 | $0.00 | ||||
| X202 | Site Design | 1 | $0.00 | 1 | $0.00 | 1 | $0.00 | $0.00 | 1 | $0.00 | 1 | $0.00 | $0.00 | ||||
| X203 | Concept Review | ||||||||||||||||
| X204 | 50% Design | ||||||||||||||||
| X205 | 95% Design | ||||||||||||||||
| X206 | Issued for Construction Drawings | ||||||||||||||||
| Total Site Design | $0.00 | Total Site Design | $0.00 | Total Site Design | $0.00 | Total Site Design | $0.00 | Total Site Design | $0.00 | $0.00 |
| Base Year | Ordering Period 1 | Ordering Period 2 | Ordering Period 3 | Ordering Period 4 | |||||||||||||
| CIVIL WORKS (FFP) | CLIN 030 | CLIN 130 | CLIN 230 | CLIN 330 | CLIN 430 | ||||||||||||
| Sub - CLIN | Description | Qty | Rate | Amount | Qty | Rate | Amount | Qty | Rate | Amount | Qty | Rate | Amount | Qty | Rate | Amount | Total |
| X300 | Mobilization and Site Preparations, Securing the site, Demobilization |
SHEYYAB, ALLA S: SHEYYAB, ALLA S:
| Assume project location is in Southern California. Construction will be completed over 6 months. Site prep includes all steps required to activiate the site to include, but not limited to, field office, site supervison personnel, equipment rental, concrete testing... | 1 | $ - 0 | 1 | $0.00 | $ - 0 | 1 | $0.00 | $ - 0 | 1 | $0.00 | $ - 0 | 1 | $0.00 | $ - 0 | $ - 0 | |
| X301 | Command Center-New Construction |
SHEYYAB, ALLA S: SHEYYAB, ALLA S:
Assume new all-steel modular building 14'x40'x10'. Including shipping but not installation
| 1 | $ - 0 | 1 | $0.00 | $ - 0 | 1 | $0.00 | $ - 0 | 1 | $0.00 | $ - 0 | 1 | $0.00 | $ - 0 | $ - 0 | |||
| X302 | Command Center-Retrofit | 0 | $ - 0 | 0 | $0.00 | $ - 0 | 0 | $0.00 | $ - 0 | 0 | $0.00 | $ - 0 | 0 | $0.00 | $ - 0 | $ - 0 | |
| X303 | Clearing/Grubbing, Earth Work , Compaction, Drainage |
SHEYYAB, ALLA S: SHEYYAB, ALLA S:
| To include trenching, excavating, backfilling and compacting, | 1 | $0.00 | $ - 0 | 1 | $0.00 | $ - 0 | 1 | $0.00 | $ - 0 | 1 | $0.00 | $ - 0 | 1 | $0.00 | $ - 0 | $ - 0 |
| Excavating, trench or continuous footing |
SHEYYAB, ALLA S: SHEYYAB, ALLA S:
| Units are in C.Y. | 3623 | $ - 0 | |
| Backfill and compact |
SHEYYAB, ALLA S: SHEYYAB, ALLA S:
| Units are in C.Y. | 3623 | $ - 0 | |
| Fixed end caisson piles, open style in stable ground, to 50' deep, 18" diameter |
SHEYYAB, ALLA S: SHEYYAB, ALLA S:
| Units are in L.F. | 984 | $ - 0 | |
| Cycle hauling |
SHEYYAB, ALLA S: SHEYYAB, ALLA S
| Units in C.Y. | 3461 | $ - 0 | |
| Demolition/Removal |
SHEYYAB, ALLA S: SHEYYAB, ALLA S:
| Assume removing 4" thick pavement. Qty in Sq. Yard units | 2478 | $ - 0 | |
| Saw Cut |
SHEYYAB, ALLA S: SHEYYAB, ALLA S:
Assume saw cutting concrete pavement 4" deep. Qty in L.F. units
| 624 | $ - 0 | ||||||||||||||||
| X304 | Electrical/Plumbing/Mechanical | 1 | $0.00 | $ - 0 | 1 | $0.00 | $ - 0 | 1 | $0.00 | $ - 0 | 1 | $0.00 | $ - 0 | 1 | $0.00 | $ - 0 | $ - 0 |
| Man holes |
SHEYYAB, ALLA S: SHEYYAB, ALLA S:
| precast w/iron racks & pulling irons, C.I. frame and cover, 2' x 2' x 2.6' deep, excludes excavation, backfill and cast in place concrete | 17 | $ - 0 | |
| Fiber optic cable, 48 strand, single mode, indoor/outdoor |
SHEYYAB, ALLA S: SHEYYAB, ALLA S:
| Units in thousand L.F. | 10 | $ - 0 | ||
| Panelboards, 3 phase 4 wire, main circuit breaker, 277/480 V, 225 amp, 30 circuits, NF, incl 20 A 1 pole bolt-on breakers | 2 | $ - 0 | ||
| Panelboards, 3 phase 4 wire, main circuit breaker, 120/208 V, 125 amp, 24 circuits, NQ, incl 20 A 1 pole bolt-on breakers | 2 | $ - 0 | ||
| Panelboards, 3 phase 4 wire, main circuit breaker, 277/480 V, 225 amp, 30 circuits, NF, incl 20 A 1 pole bolt-on breakers | 1 | $ - 0 | ||
| Panelboards, 1 phase 3 wire, main circuit breaker, 120/240 V, 100 amp, 20 circuits, NQ, incl 20 A 1 pole bolt-on breakers | 1 | $ - 0 | ||
| Electrical underground PVC conduit with coupling, 2" diameter |
SHEYYAB, ALLA S: SHEYYAB, ALLA S:
| Units in L.F. schedule 40, installed by direct burial in slab or duct bank, excludes excavation, backfill and cast in place concrete | 5564 | $ - 0 | |
| Electrical underground PVC conduit with coupling, 3" diameter |
SHEYYAB, ALLA S: SHEYYAB, ALLA S:
| Units in L.F. schedule 40, installed by direct burial in slab or duct bank, excludes excavation, backfill and cast in place concrete | 1844 | $ - 0 | |
| Electrical underground PVC conduit with coupling, 4" diameter |
SHEYYAB, ALLA S: SHEYYAB, ALLA S:
| Units in L.F. schedule 40, installed by direct burial in slab or duct bank, excludes excavation, backfill and cast in place concrete | 2344 | $ - 0 | |
| Electric metallic tubing (EMT), 4" diameter |
SHEYYAB, ALLA S: SHEYYAB, ALLA S:
| Units in L.F. to 10' high, incl 2 terminations, 2 elbows, 11 beam clamps, and 11 couplings per 100 LF | 730 | $ - 0 | ||||||||||||||||
| X305 | Concrete/Asphalt/Footers/Foundations/Lanes of Traffic | 1 | $0.00 | $ - 0 | 1 | $0.00 | $ - 0 | 1 | $0.00 | $ - 0 | 1 | $0.00 | $ - 0 | 1 | $0.00 | $ - 0 | $ - 0 | |
| 12" thick (4000 psi) SOG above the gravel vehicle station three rows |
SHEYYAB, ALLA S: SHEYYAB, ALLA S:
| Units in Cubic Ft. Grade 60 rebar, concrete (Portland cement Type I), placing and finishing | 10356 | $ - 0 | |
| Expansion joint, premolded, bituminous fiber, 1" x 12" |
SHEYYAB, ALLA S: SHEYYAB, ALLA S:
| Qty in L.Ft. units | 2676 | $ - 0 | ||
| Pump, pedestal sump, single stage, 25 GPM, 1 H.P., 1-1/2" discharge | 6 | $ - 0 | ||
| Concrete surface treatment, curing, sprayed membrane compound |
SHEYYAB, ALLA S: SHEYYAB, ALLA S:
| Qty in Sq.Ft. | 265 | $ - 0 | ||||||||||||||||
| X306 | Traffic Control Measures, Jersey Barriers, Speed bumps, striping, signage | 1 | $0.00 | $ - 0 | 1 | $0.00 | $ - 0 | 1 | $0.00 | $ - 0 | 1 | $0.00 | $ - 0 | 1 | $0.00 | $ - 0 | $ - 0 | |
| Metal parking bumpers, pipe bollards, concrete filled/painted, 8' L x 4' D hole, 6" diam. | 24 | $ - 0 | ||||||||||||||||
| Vehicle guide rails, guide/guard rail, Rub Rail |
SHEYYAB, ALLA S: SHEYYAB, ALLA S:
| Qty in L.Ft. steel, galv, steel posts (not included), 2m OC, | 996 | $ - 0 | |||||||||||
| Security vehicle barriers, pipe bollards, steel, concrete filled/painted, 8' L x 4' D hole, 8" diam. | 24 | $ - 0 | |||||||||||
| Security vehicle barriers, concrete barrier, jersey, 10' L x 2' by 6" W x 32" H | 66 | $ - 0 | |||||||||||
| X307 | Site Survey | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |
| X308 | SWPPP, Permitting | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |
| X309 | Lodging & Boarding PerDiem | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |
| X310 | Adjustment Factor (Construction Contingency, Scraps…) | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 |
Total Civil Works $ - 0 Total Civil Works $ - 0 Total Civil Works $ - 0 Total Civil Works $ - 0 Total Civil Works $ - 0 $ - 0
| Base Year | Ordering Period 1 | Ordering Period 2 | Ordering Period 3 | Ordering Period 4 | |||||||||||||
| FURNITURE, FIXTURES, AND EQUIPMENT (FFP) | CLIN 040 | CLIN 140 | CLIN 240 | CLIN 340 | CLIN 440 | ||||||||||||
| Sub - CLIN | Description | Qty | Rate | Amount | Qty | Rate | Amount | Qty | Rate | Amount | Qty | Rate | Amount | Qty | Rate | Amount | Total |
| X400 | Analyst Station | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |||||
| X401 | Operator Station | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |||||
| X402 | Situational Wall | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |||||
| X403 | Furniture and fixtures | 1 | $100,000.00 | $ 100,000.00 | 1 | $105,000.00 | $ 105,000.00 | 1 | $110,250.00 | $ 110,250.00 | 1 | $115,762.50 | $ 115,762.50 | 1 | $121,550.63 | $ 121,550.63 | $ 552,563.13 |
| X404 | Generators | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |||||
| X405 | Uninterrupted Power Supplies (75 kVA) |
SHEYYAB, ALLA S: SHEYYAB, ALLA S:
| Including installation | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |
| X405 | Uninterrupted Power Supplies (125 kVA) |
SHEYYAB, ALLA S: SHEYYAB, ALLA S:
| Including installation | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |
| X405 | Uninterrupted Power Supplies (150 kVA) |
SHEYYAB, ALLA S: SHEYYAB, ALLA S:
Including installation
SHEYYAB, ALLA S: SHEYYAB, ALLA S:
Units in L.F. schedule 40, installed by direct burial in slab or duct bank, excludes excavation, backfill and cast in place concrete
SHEYYAB, ALLA S: SHEYYAB, ALLA S:
Units in L.F. schedule 40, installed by direct burial in slab or duct bank, excludes excavation, backfill and cast in place concrete
SHEYYAB, ALLA S: SHEYYAB, ALLA S:
Units in L.F. schedule 40, installed by direct burial in slab or duct bank, excludes excavation, backfill and cast in place concrete
SHEYYAB, ALLA S: SHEYYAB, ALLA S:
Units in L.F. to 10' high, incl 2 terminations, 2 elbows, 11 beam clamps, and 11 couplings per 100 LF
SHEYYAB, ALLA S: SHEYYAB, ALLA S:
Units in Cubic Ft. Grade 60 rebar, concrete (Portland cement Type I), placing and finishing
SHEYYAB, ALLA S: SHEYYAB, ALLA S:
Qty in L.Ft. units
SHEYYAB, ALLA S: SHEYYAB, ALLA S:
Qty in Sq.Ft.
SHEYYAB, ALLA S: SHEYYAB, ALLA S:
| Qty in L.Ft. steel, galv, steel posts (not included), 2m OC, | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |||||||
| X406 | Power Conditioners | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | ||||||
| X407 | Operator Booth (8'x12') | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | ||||||
| X408 | Operator Booth (12'x16') | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | ||||||
| X409 | Laptops | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | ||||||
| X410 | Transformer, dry-type, 3 phase 480 V primary 120/208 V secondary, 150 kVA, K-13 rated | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 |
Total FF&E $ 100,000.00 Total Construction $ 105,000.00 Total Construction $ 110,250.00 Total Construction $ 115,762.50 Total Construction $ 121,550.63 $ 552,563.13
| Base Year | Ordering Period 1 | Ordering Period 2 | Ordering Period 3 | Ordering Period 4 | |||||||||||||
| INSTALLATION (FFP) | CLIN 050 | CLIN 150 | CLIN 250 | CLIN 350 | CLIN 450 | ||||||||||||
| Sub - CLIN | Description | Rate | Amount | Rate | Amount | Rate | Amount | Rate | Amount | Rate | Amount | Total | |||||
| X500 | Installation | 2 | $ - 0 | 2 | $ - 0 | 2 | $ - 0 | 2 | $ - 0 | 2 | $ - 0 | $ - 0 | |||||
| X501 | Integration | 2 | $ - 0 | 2 | $ - 0 | 2 | $ - 0 | 2 | $ - 0 | 2 | $ - 0 | $ - 0 | |||||
| X502 | Radiation Blanking Solution | 2 | $ - 0 | 2 | $ - 0 | 2 | $ - 0 | 2 | $ - 0 | 2 | $ - 0 | $ - 0 | |||||
| X503 | System Testing | 2 | $ - 0 | 2 | $ - 0 | 2 | $ - 0 | 2 | $ - 0 | 2 | $ - 0 | $ - 0 | |||||
| X505 | License Plate Reader (LPR) | 2 | $ - 0 | 2 | $ - 0 | 2 | $ - 0 | 2 | $ - 0 | 2 | $ - 0 | $ - 0 | |||||
| X506 | Pan-Tilt-Zoom (PTZ) Camera | 2 | $ - 0 | 2 | $ - 0 | 2 | $ - 0 | 2 | $ - 0 | 2 | $ - 0 | $ - 0 | |||||
| X507 | Optical Character Recognition System | 2 | $ - 0 | 2 | $ - 0 | 2 | $ - 0 | 2 | $ - 0 | 2 | $ - 0 | $ - 0 | |||||
| X508 | Traffic Control System | 2 | $ - 0 | 2 | $ - 0 | 2 | $ - 0 | 2 | $ - 0 | 2 | $ - 0 | $ - 0 |
Total Installation $ - 0 Total Installation $ - 0 Total Installation $ - 0 Total Installation $ - 0 Total Installation $ - 0 $ - 0
| Base Year | Ordering Period 1 | Ordering Period 2 | Ordering Period 3 | Ordering Period 4 | |||||||||||||
| TRAINING (FFP) | CLIN 060 | CLIN 160 | CLIN 260 | CLIN 360 | CLIN 460 | ||||||||||||
| Sub-CLIN | Description | Qty | Rate | Amount | Qty | Rate | Amount | Qty | Rate | Amount | Qty | Rate | Amount | Qty | Rate | Amount | |
| X600 | Training Development | 1 | $ - 0 | 0 | $ - 0 | 0 | $ - 0 | 0 | $ - 0 | 0 | $ - 0 | $ - 0 |
Total Training $ - 0 Total Training $ - 0 Total Training $ - 0 Total Training $ - 0 Total Training $ - 0 $ - 0
| Base Year | Ordering Period 1 | Ordering Period 2 | Ordering Period 3 | Ordering Period 4 | |||||||||||||
| PREVENTATIVE MAINTENANCE OPTIONS (FFP) | CLIN 070 | CLIN 170 | CLIN 270 | CLIN 370 | CLIN 470 | ||||||||||||
| Sub-CLIN | Description | Qty | Rate | Amount | Qty | Rate | Amount | Qty | Rate | Amount | Qty | Rate | Amount | Qty | Rate | Amount | |
| X700 | MEP Service | 0 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |||||
| X701 | UVBx Service | 0 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |||||
| Total Preventative Maintenance (UVBx) | $ - 0 | Total Preventative Maintenance (UVBx) | $ - 0 | Total Preventative Maintenance (UVBx) | $ - 0 | Total Preventative Maintenance (UVBx) | $ - 0 | Total Preventative Maintenance (UVBx) | $ - 0 | $ - 0 |
| Base Year | Ordering Period 1 | Ordering Period 2 | Ordering Period 3 | Ordering Period 4 | |||||||||||||
| CORRECTIVE MAINTENANCE OPTIONS (FFP) (parts, labor, diagnostics, and repair) | CLIN 080 | CLIN 180 | CLIN 280 | CLIN 380 | CLIN 480 | ||||||||||||
| Sub-CLIN | Description | Qty | Rate | Amount | Qty | Rate | Amount | Qty | Rate | Amount | Qty | Rate | Amount | Qty | Rate | Amount | |
| X800 | MEP Service | 0 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |||||
| X801 | UVBx Service | 0 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |||||
| Total Corrective Maintenance (UVBx) | $ - 0 | Total Corrective Maintenance (UVBx) | $ - 0 | Total Corrective Maintenance (UVBx) | $ - 0 | Total Corrective Maintenance (UVBx) | $ - 0 | Total Corrective Maintenance (UVBx) | $ - 0 | $ - 0 |
| Base Year | Ordering Period 1 | Ordering Period 2 | Ordering Period 3 | Ordering Period 4 | |||||||||||||
| WARRANTY PERIODS (FFP) | CLIN 090 | CLIN 190 | CLIN 290 | CLIN 390 | CLIN 490 | ||||||||||||
| Sub-CLIN | Description | Qty | Rate | Amount | Qty | Rate | Amount | Qty | Rate | Amount | Qty | Rate | Amount | Qty | Rate | Amount | Total |
| X110 | MEP-Required Comprehensive Base Warranty (1 Year) | 1 | $ - 0 | 0 | $ - 0 | 0 | $ - 0 | 0 | $ - 0 | 0 | $ - 0 | $ - 0 | |||||
| X111 | MEP-Two Years of Warranty | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |||||
| X112 | MEP-Three Years of Warranty | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |||||
| X113 | MEP-Four Years of Warranty | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |||||
| X114 | MEP-Five Years of Warranty | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |||||
| X115 | UVBx-Required Comprehensive Base Warranty (1 Year) | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |||||
| X116 | UVBx-Two Years of Warranty | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |||||
| X117 | UVBx-Three Years of Warranty | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |||||
| X118 | UVBx-Four Years of Warranty | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |||||
| X119 | UVBx-Five Years of Warranty | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 |
Total Warranty $ - 0 Total General Requirements $ - 0 Total General Requirements $ - 0 Total General Requirements $ - 0 Total General Requirements $ - 0 $ - 0
| Base Year | Ordering Period 1 | Ordering Period 2 | Ordering Period 3 | Ordering Period 4 | |||||||||||||
| ON-DEMAND SERVICES (FFP) | CLIN 100 | CLIN 200 | CLIN 300 | CLIN 400 | CLIN 500 | ||||||||||||
| Sub-CLIN | Description | Qty | Rate | Amount | Qty | Rate | Amount | Qty | Rate | Amount | Qty | Rate | Amount | Qty | Rate | Amount | Total |
| X120 | On-Demand Services | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |||||
| Engineering Services | |||||||||||||||||
| Ad Hoc Reports | |||||||||||||||||
| Site Surveys | |||||||||||||||||
| Provisioning Support | |||||||||||||||||
| Retrofit Support | |||||||||||||||||
| Relocation Services | |||||||||||||||||
| Site Work | |||||||||||||||||
| Disposal | |||||||||||||||||
| Emergency Services | |||||||||||||||||
| Special Events | |||||||||||||||||
| Training Activities | |||||||||||||||||
| Total On-Demand | $ - 0 | Total General Requirements | $ - 0 | Total General Requirements | $ - 0 | Total General Requirements | $ - 0 | Total General Requirements | $ - 0 | $ - 0 |
| Base Year | Ordering Period 1 | Ordering Period 2 | Ordering Period 3 | Ordering Period 4 | ||||||||||||
| INDIRECT RATES | ||||||||||||||||
| Sub-CLIN | Description | Qty | Rate | Amount | Qty | Rate | Amount | Qty | Rate | Amount | Qty | Rate | Amount | Qty | Rate | Amount |
| X142 | G&A | 1 | 1 | 1 | 1 | 1 | ||||||||||
| X143 | M&H | 1 | 1 | 1 | 1 | 1 | ||||||||||
| X144 | Profit | 1 | 1 | 1 | 1 | 1 |
Total Indirect Rates $ - 0 Total Indirect Rates $ - 0 Total Indirect Rates $ - 0 Total Indirect Rates $ - 0 Total Indirect Rates $ - 0
| INCENTIVE POOL | |||||||||||||||||
| Sub-CLIN | Description (would need a CLIN for each Option Year) | Qty | Rate | Amount | Qty | Rate | Amount | Qty | Rate | Amount | Qty | Rate | Amount | Qty | Rate | Amount | |
| Year 1 Incentives: Equipment CLIN | 1 | $0.00 | $0.00 | 1 | $0.00 | $0.00 | 1 | $0.00 | $0.00 | 1 | $0.00 | $0.00 | 1 | $0.00 | $0.00 | $ - 0 | |
| Year 1 Incentives: Warranty CLIN | 1 | $0.00 | $0.00 | 1 | $0.00 | $0.00 | 1 | $0.00 | $0.00 | 1 | $0.00 | $0.00 | 1 | $0.00 | $0.00 | $ - 0 | |
| Total General Requirements | $0.00 | Total General Requirements | $0.00 | Total General Requirements | $0.00 | Total General Requirements | $0.00 | Total General Requirements | $0.00 | $0.00 |
| Total Price Per Period | $100,000.00 | $105,000.00 | $110,250.00 | $115,762.50 | $121,550.63 | $ 552,563.13 |
| Check | ||||||
| ERROR:#REF! |
&1#&"Times New Roman"&10&K000000SENSITIVE BUT UNCLASSIFIED
LEP CLINs
| Contractor Name: | |
| Solicitation Number: | |
| Task Order Number: | |
| Task Order Title: | * The installation site is in Southern California |
| * The LEP is a 3 lane new installation project | |
| * Don't change the provided quantities in the blue shaded cells | |
| * The project is to be completed in 6 months | |
| * Please refer to the notes included in column B for additional details |
| Base Year | Ordering Period 1 | Ordering Period 2 | Ordering Period 3 | Ordering Period 4 | |||||||||||||
| EQUIPMENT - LOW ENERGY PORTAL SYSTEM (FFP) | CLIN 010 | CLIN 110 | CLIN 210 | CLIN 310 | CLIN 410 | ||||||||||||
| Sub-CLIN | Description | Qty | Rate | Amount | Qty | Rate | Amount | Qty | Rate | Amount | Qty | Rate | Amount | Qty | Rate | Amount | Total |
| X104 | LEP-Type 1 | 1 | $0.00 | 1 | $0.00 | 1 | $0.00 | 1 | $0.00 | 1 | $0.00 | $0.00 | |||||
| X108 | LEP-Type 2 | 1 | $0.00 | 1 | $0.00 | 1 | $0.00 | 1 | $0.00 | 1 | $0.00 | $0.00 | |||||
| X112 | LEP-Type 3 | 1 | $0.00 | 1 | $0.00 | 1 | $0.00 | 1 | $0.00 | 1 | $0.00 | $0.00 | |||||
| X116 | UVBx | 3 | $0.00 | 3 | $0.00 | 3 | $0.00 | 3 | $0.00 | 3 | $0.00 | $0.00 |
Total Equipment $0.00 Total Equipment Management $0.00 Total Equipment Management $0.00 Total Equipment Management $0.00 Total Equipment Management $0.00 $0.00
| Base Year | Ordering Period 1 | Ordering Period 2 | Ordering Period 3 | Ordering Period 4 | |||||||||||||
| SITE DESIGN (FFP) | CLIN 020 | CLIN 120 | CLIN 220 | CLIN 320 | CLIN 420 | ||||||||||||
| Sub-CLIN | Description | Qty | Rate | Amount | Qty | Rate | Amount | Qty | Rate | Amount | Qty | Rate | Amount | Qty | Rate | Amount | Total |
| X200 | Program Management and Operations Labor- Fully Burdened | 1 | $0.00 | 1 | $0.00 | 1 | $0.00 | 1 | $0.00 | 1 | $0.00 | $0.00 | |||||
| X201 | Travel | 1 | $0.00 | 1 | $0.00 | 1 | $0.00 | 1 | $0.00 | 1 | $0.00 | $0.00 | |||||
| X202 | Site Design | 1 | $0.00 | 1 | $0.00 | 1 | $0.00 | 1 | $0.00 | 1 | $0.00 | $0.00 | |||||
| X203 | Concept Review | $0.00 | |||||||||||||||
| X204 | 50% Design | $0.00 | |||||||||||||||
| X205 | 95% Design | $0.00 | |||||||||||||||
| X206 | Issued for Construction Drawings | $0.00 | |||||||||||||||
| Total Site Design | $0.00 | Total Site Design | $0.00 | Total Site Design | $0.00 | Total Site Design | $0.00 | Total Site Design | $0.00 | $0.00 |
| Base Year | Ordering Period 1 | Ordering Period 2 | Ordering Period 3 | Ordering Period 4 | |||||||||||||
| CIVIL WORKS (FFP) | CLIN 030 | CLIN 130 | CLIN 230 | CLIN 330 | CLIN 430 | ||||||||||||
| Sub - CLIN | Description | Qty | Rate | Amount | Qty | Rate | Amount | Qty | Rate | Amount | Qty | Rate | Amount | Qty | Rate | Amount | Total |
| X300 | Mobilization and Site Preparations, Securing the site, Demobilization | 1 | $ - 0 | 1 | $ - 0 | 1 | $0.00 | $ - 0 | 1 | $0.00 | $ - 0 | 1 | $0.00 | $ - 0 | $ - 0 | ||
| X301 | Command Center-New Construction | 1 | $ - 0 | 1 | $ - 0 | 1 | $0.00 | $ - 0 | 1 | $0.00 | $ - 0 | 1 | $0.00 | $ - 0 | $ - 0 | ||
| X302 | Command Center-Retrofit | 1 | $ - 0 | 1 | $ - 0 | 1 | $0.00 | $ - 0 | 1 | $0.00 | $ - 0 | 1 | $0.00 | $ - 0 | $ - 0 | ||
| X303 | Clearing/Grubbing, Earth Work , Compaction, Drainage |
SHEYYAB, ALLA S: SHEYYAB, ALLA S:
| To include trenching, excavating, backfilling and compacting, | 1 | $0.00 | $ - 0 | 1 | $0.00 | $ - 0 | 1 | $0.00 | $ - 0 | 1 | $0.00 | $ - 0 | 1 | $0.00 | $ - 0 | $ - 0 |
| Excavating, trench or continuous footing |
SHEYYAB, ALLA S: SHEYYAB, ALLA S:
| Units are in C.Y. | 3623 | $ - 0 | |
| Backfill and compact |
SHEYYAB, ALLA S: SHEYYAB, ALLA S:
| Units are in C.Y. | 3623 | $ - 0 | |
| Fixed end caisson piles, open style in stable ground, to 50' deep, 18" diameter |
SHEYYAB, ALLA S: SHEYYAB, ALLA S:
| Units are in L.F. | 984 | $ - 0 | |
| Cycle hauling |
SHEYYAB, ALLA S: SHEYYAB, ALLA S
| Units in C.Y. | 3461 | $ - 0 | |
| Demolition/Removal |
SHEYYAB, ALLA S: SHEYYAB, ALLA S:
| Assume removing 4" thick pavement. Qty in Sq. Yard units | 2478 | $ - 0 | |
| Saw Cut |
SHEYYAB, ALLA S: SHEYYAB, ALLA S:
Assume saw cutting concrete pavement 4" deep. Qty in L.F. units
| 624 | $ - 0 | ||||||||||||||||
| X304 | Electrical/Plumbing/Mechanical | 1 | $0.00 | $ - 0 | 1 | $0.00 | $ - 0 | 1 | $0.00 | $ - 0 | 1 | $0.00 | $ - 0 | 1 | $0.00 | $ - 0 | $ - 0 |
| Man holes |
SHEYYAB, ALLA S: SHEYYAB, ALLA S:
| precast w/iron racks & pulling irons, C.I. frame and cover, 2' x 2' x 2.6' deep, excludes excavation, backfill and cast in place concrete | 17 | $ - 0 | |
| Fiber optic cable, 48 strand, single mode, indoor/outdoor |
SHEYYAB, ALLA S: SHEYYAB, ALLA S:
| Units in thousand L.F. | 10 | $ - 0 | ||
| Panelboards, 3 phase 4 wire, main circuit breaker, 277/480 V, 225 amp, 30 circuits, NF, incl 20 A 1 pole bolt-on breakers | 2 | $ - 0 | ||
| Panelboards, 3 phase 4 wire, main circuit breaker, 120/208 V, 125 amp, 24 circuits, NQ, incl 20 A 1 pole bolt-on breakers | 2 | $ - 0 | ||
| Panelboards, 3 phase 4 wire, main circuit breaker, 277/480 V, 225 amp, 30 circuits, NF, incl 20 A 1 pole bolt-on breakers | 1 | $ - 0 | ||
| Panelboards, 1 phase 3 wire, main circuit breaker, 120/240 V, 100 amp, 20 circuits, NQ, incl 20 A 1 pole bolt-on breakers | 1 | $ - 0 | ||
| Electrical underground PVC conduit with coupling, 2" diameter |
SHEYYAB, ALLA S: SHEYYAB, ALLA S:
| Units in L.F. schedule 40, installed by direct burial in slab or duct bank, excludes excavation, backfill and cast in place concrete | 5564 | $ - 0 | |
| Electrical underground PVC conduit with coupling, 3" diameter |
SHEYYAB, ALLA S: SHEYYAB, ALLA S:
| Units in L.F. schedule 40, installed by direct burial in slab or duct bank, excludes excavation, backfill and cast in place concrete | 1844 | $ - 0 | |
| Electrical underground PVC conduit with coupling, 4" diameter |
SHEYYAB, ALLA S: SHEYYAB, ALLA S:
| Units in L.F. schedule 40, installed by direct burial in slab or duct bank, excludes excavation, backfill and cast in place concrete | 2344 | $ - 0 | |
| Electric metallic tubing (EMT), 4" diameter |
SHEYYAB, ALLA S: SHEYYAB, ALLA S:
| Units in L.F. to 10' high, incl 2 terminations, 2 elbows, 11 beam clamps, and 11 couplings per 100 LF | 730 | $ - 0 | ||||||||||||||||
| X305 | Concrete/Asphalt/Footers/Foundations/Lanes of Traffic | 1 | $0.00 | $ - 0 | 1 | $0.00 | $ - 0 | 1 | $0.00 | $ - 0 | 1 | $0.00 | $ - 0 | 1 | $0.00 | $ - 0 | $ - 0 | |
| 12" thick (4000 psi) SOG above the gravel vehicle station three rows |
SHEYYAB, ALLA S: SHEYYAB, ALLA S:
| Units in Cubic Ft. Grade 60 rebar, concrete (Portland cement Type I), placing and finishing | 10356 | $ - 0 | |
| Expansion joint, premolded, bituminous fiber, 1" x 12" |
SHEYYAB, ALLA S: SHEYYAB, ALLA S:
| Qty in L.Ft. units | 2676 | $ - 0 | ||
| Pump, pedestal sump, single stage, 25 GPM, 1 H.P., 1-1/2" discharge | 6 | $ - 0 | ||
| Concrete surface treatment, curing, sprayed membrane compound |
SHEYYAB, ALLA S: SHEYYAB, ALLA S:
| Qty in Sq.Ft. | 265 | $ - 0 | ||||||||||||||||
| X306 | Traffic Control Measures, Jersey Barriers, Speed bumps, striping, signage | 1 | $0.00 | $ - 0 | 1 | $0.00 | $ - 0 | 1 | $0.00 | $ - 0 | 1 | $0.00 | $ - 0 | 1 | $0.00 | $ - 0 | $ - 0 | |
| Metal parking bumpers, pipe bollards, concrete filled/painted, 8' L x 4' D hole, 6" diam. | 24 | $ - 0 | ||||||||||||||||
| Vehicle guide rails, guide/guard rail, Rub Rail |
SHEYYAB, ALLA S: SHEYYAB, ALLA S:
| Qty in L.Ft. steel, galv, steel posts (not included), 2m OC, | 996 | $ - 0 | |||||||||||
| Security vehicle barriers, pipe bollards, steel, concrete filled/painted, 8' L x 4' D hole, 8" diam. | 24 | $ - 0 | |||||||||||
| Security vehicle barriers, concrete barrier, jersey, 10' L x 2' by 6" W x 32" H | 66 | $ - 0 | |||||||||||
| X307 | Site Survey | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |
| X308 | SWPPP, Permitting | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |
| X309 | Lodging & Boarding PerDiem | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |
| X310 | Adjustment Factor (Construction Contingency, Scraps…) | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 |
Total Civil Works $ - 0 Total Civil Works $ - 0 Total Civil Works $ - 0 Total Civil Works $ - 0 Total Civil Works $ - 0 $ - 0
| Base Year | Ordering Period 1 | Ordering Period 2 | Ordering Period 3 | Ordering Period 4 | |||||||||||||
| FURNITURE, FIXTURES, AND EQUIPMENT (FFP) | CLIN 040 | CLIN 140 | CLIN 240 | CLIN 340 | CLIN 440 | ||||||||||||
| Sub - CLIN | Description | Qty | Rate | Amount | Qty | Rate | Amount | Qty | Rate | Amount | Qty | Rate | Amount | Qty | Rate | Amount | Total |
| X400 | Analyst Station | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |||||
| X401 | Operator Station | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |||||
| X402 | Situational Wall | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |||||
| X403 | Furniture and fixtures | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |||||
| X404 | Generators | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |||||
| X405 | Uninterrupted Power Supplies (75 kVA) |
SHEYYAB, ALLA S: SHEYYAB, ALLA S:
| Including installation | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |
| X405 | Uninterrupted Power Supplies (125 kVA) |
SHEYYAB, ALLA S: SHEYYAB, ALLA S:
| Including installation | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |
| X405 | Uninterrupted Power Supplies (150 kVA) |
SHEYYAB, ALLA S: SHEYYAB, ALLA S:
Including installation
SHEYYAB, ALLA S: SHEYYAB, ALLA S:
Units in L.F. schedule 40, installed by direct burial in slab or duct bank, excludes excavation, backfill and cast in place concrete
SHEYYAB, ALLA S: SHEYYAB, ALLA S:
Units in L.F. schedule 40, installed by direct burial in slab or duct bank, excludes excavation, backfill and cast in place concrete
SHEYYAB, ALLA S: SHEYYAB, ALLA S:
Units in L.F. schedule 40, installed by direct burial in slab or duct bank, excludes excavation, backfill and cast in place concrete
SHEYYAB, ALLA S: SHEYYAB, ALLA S:
Units in L.F. to 10' high, incl 2 terminations, 2 elbows, 11 beam clamps, and 11 couplings per 100 LF
SHEYYAB, ALLA S: SHEYYAB, ALLA S:
| Units in Cubic Ft. Grade 60 rebar, concrete (Portland cement Type I), placing and finishing | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |||||||
| X406 | Power Conditioners | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | ||||||
| X407 | Operator Booth (8'x12') | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | ||||||
| X408 | Operator Booth (12'x16') | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | ||||||
| X409 | Laptops | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | ||||||
| X410 | Transformer, dry-type, 3 phase 480 V primary 120/208 V secondary, 150 kVA, K-13 rated | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 |
Total FF&E $ - 0 Total Construction $ - 0 Total Construction $ - 0 Total Construction $ - 0 Total Construction $ - 0 $ - 0
| Base Year | Ordering Period 1 | Ordering Period 2 | Ordering Period 3 | Ordering Period 4 | |||||||||||||
| INSTALLATION (FFP) | CLIN 050 | CLIN 150 | CLIN 250 | CLIN 350 | CLIN 450 | ||||||||||||
| Sub - CLIN | Description | Rate | Amount | Rate | Amount | Rate | Amount | Rate | Amount | Rate | Amount | Total | |||||
| X500 | Installation | 3 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |||||
| X501 | Integration | 3 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |||||
| X502 | Blanking Solution | 3 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |||||
| X503 | System Testing | 3 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |||||
| X505 | License Plate Reader (LPR) | 3 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |||||
| X506 | Pan-Tilt-Zoom (PTZ) Camera | 3 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |||||
| X507 | Optical Character Recognition System | 3 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |||||
| X508 | Traffic Control System | 3 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 |
Total Installation $ - 0 Total Installation $ - 0 Total Installation $ - 0 Total Installation $ - 0 Total Installation $ - 0 $ - 0
| Base Year | Ordering Period 1 | Ordering Period 2 | Ordering Period 3 | Ordering Period 4 | |||||||||||||
| TRAINING (FFP) | CLIN 060 | CLIN 160 | CLIN 260 | CLIN 360 | CLIN 460 | ||||||||||||
| Sub-CLIN | Description | Qty | Rate | Amount | Qty | Rate | Amount | Qty | Rate | Amount | Qty | Rate | Amount | Qty | Rate | Amount | |
| X600 | Training Development | 1 | $ - 0 | 0 | $ - 0 | 0 | $ - 0 | 0 | $ - 0 | 0 | $ - 0 | $ - 0 |
Total Training $ - 0 Total Training $ - 0 Total Training $ - 0 Total Training $ - 0 Total Training $ - 0 $ - 0
| Base Year | Ordering Period 1 | Ordering Period 2 | Ordering Period 3 | Ordering Period 4 | |||||||||||||
| PREVENTATIVE MAINTENANCE OPTIONS (FFP) | CLIN 070 | CLIN 170 | CLIN 270 | CLIN 370 | CLIN 470 | ||||||||||||
| Sub-CLIN | Description | Qty | Rate | Amount | Qty | Rate | Amount | Qty | Rate | Amount | Qty | Rate | Amount | Qty | Rate | Amount | |
| X700 | LEP Service | 0 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |||||
| X701 | UVBx Service | 0 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |||||
| Total Preventative Maintenance (UVBx) | $ - 0 | Total Preventative Maintenance (UVBx) | $ - 0 | Total Preventative Maintenance (UVBx) | $ - 0 | Total Preventative Maintenance (UVBx) | $ - 0 | Total Preventative Maintenance (UVBx) | $ - 0 | $ - 0 |
| Base Year | Ordering Period 1 | Ordering Period 2 | Ordering Period 3 | Ordering Period 4 | |||||||||||||
| CORRECTIVE MAINTENANCE OPTIONS (FFP) | CLIN 080 | CLIN 180 | CLIN 280 | CLIN 380 | CLIN 480 | ||||||||||||
| Sub-CLIN | Description | Qty | Rate | Amount | Qty | Rate | Amount | Qty | Rate | Amount | Qty | Rate | Amount | Qty | Rate | Amount | |
| X800 | LEP Service | 0 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |||||
| X801 | UVBx Service | 0 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |||||
| Total Corrective Maintenance (UVBx) | $ - 0 | Total Corrective Maintenance (UVBx) | $ - 0 | Total Corrective Maintenance (UVBx) | $ - 0 | Total Corrective Maintenance (UVBx) | $ - 0 | Total Corrective Maintenance (UVBx) | $ - 0 | $ - 0 |
| Base Year | Ordering Period 1 | Ordering Period 2 | Ordering Period 3 | Ordering Period 4 | |||||||||||||
| WARRANTY PERIODS (FFP) | CLIN 090 | CLIN 190 | CLIN 290 | CLIN 390 | CLIN 490 | ||||||||||||
| Sub-CLIN | Description | Qty | Rate | Amount | Qty | Rate | Amount | Qty | Rate | Amount | Qty | Rate | Amount | Qty | Rate | Amount | Total |
| X110 | LEP-Required Comprehensive Base Warranty (1 Year) | 1 | $ - 0 | 0 | $ - 0 | 0 | $ - 0 | 0 | $ - 0 | 0 | $ - 0 | $ - 0 | |||||
| X126 | LEP-Type 1 Two Years of Warranty | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |||||
| X127 | LEP-Type 1 Three Years of Warranty | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |||||
| X128 | LEP Type 1 Four Years of Warranty | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |||||
| X129 | LEP Type 1 Five Years of Warranty | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |||||
| X130 | LEP-Type 2 Two Years of Warranty | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |||||
| X131 | LEP-Type 2 Three Years of Warranty | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |||||
| X132 | LEP Type 2 Four Years of Warranty | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |||||
| X133 | LEP Type 2 Five Years of Warranty | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |||||
| X134 | LEP-Type 3 Two Years of Warranty | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |||||
| X135 | LEP-Type 3 Three Years of Warranty | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |||||
| X136 | LEP Type 3 Four Years of Warranty | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |||||
| X137 | LEP Type 3 Five Years of Warranty | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |||||
| X115 | UVBx-Required Comprehensive Base Warranty (1 Year) | 1 | $ - 0 | 0 | $ - 0 | 0 | $ - 0 | 0 | $ - 0 | 0 | $ - 0 | $ - 0 | |||||
| X138 | UVBx-Two Years of Warranty | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |||||
| X139 | UVBx-Three Years of Warranty | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |||||
| X140 | UVBx-Four Years of Warranty | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |||||
| X141 | UVBx-Five Years of Warranty | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 |
Total Warranty $ - 0 Total General Requirements $ - 0 Total General Requirements $ - 0 Total General Requirements $ - 0 Total General Requirements $ - 0 $ - 0
| Base Year | Ordering Period 1 | Ordering Period 2 | Ordering Period 3 | Ordering Period 4 | |
| ON-DEMAND SERVICES (FFP) |
tc={E7390B8D-EE95-4665-A268-9E4FDA9CD2C5}: [Threaded comment]
Your version of Excel allows you to read this threaded comment; however, any edits to it will get removed if the file is opened in a newer version of Excel. Learn more: https://go.microsoft.com/fwlink/?linkid=870924
[Tasks]
There is a task anchored to this comment that cannot be viewed in your client.
Comment:
@SHEYYAB, ALLA S I added an on-demand services section here we will need to work on completing.
Reply:
My understanding is this line is for on-demand repair services (at least that’s my understanding from ILD spreadsheet). Some of the sub-CLINs here, such as “site work” are covered under civil works. It’s close to impossible to try and break the site work cost out of the civil works CLIN. I recommend renaming the “Civil works” CLIN if on-demand services is the preferred name
SHEYYAB, ALLA S: SHEYYAB, ALLA S:
Qty in L.Ft. units
SHEYYAB, ALLA S: SHEYYAB, ALLA S:
Qty in Sq.Ft.
SHEYYAB, ALLA S: SHEYYAB, ALLA S:
| Qty in L.Ft. steel, galv, steel posts (not included), 2m OC, | CLIN 100 | CLIN 200 | CLIN 300 | CLIN 400 | CLIN 500 | |||||||||||||
| Sub-CLIN | Description | Qty | Rate | Amount | Qty | Rate | Amount | Qty | Rate | Amount | Qty | Rate | Amount | Qty | Rate | Amount | Total | |
| X126 | On-Demand Services (On-demand system repair) | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | ||||||
| Engineering Services | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |||||||
| Ad Hoc Reports | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |||||||
| Site Surverys | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |||||||
| Provisioning Support | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |||||||
| Retrofit Support | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |||||||
| Relocation Services | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |||||||
| Site Work | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |||||||
| Disposal | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |||||||
| Emergency Services | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |||||||
| Special Events | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |||||||
| Training Activities | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |||||||
| Total On-Demand | $ - 0 | Total General Requirements | $ - 0 | Total General Requirements | $ - 0 | Total General Requirements | $ - 0 | Total General Requirements | $ - 0 | $ - 0 |
| Base Year | Ordering Period 1 | Ordering Period 2 | Ordering Period 3 | Ordering Period 4 | |||||||||||||
| INDIRECT RATES | |||||||||||||||||
| Sub-CLIN | Description | Qty | Rate | Amount | Qty | Rate | Amount | Qty | Rate | Amount | Qty | Rate | Amount | Qty | Rate | Amount | |
| X142 | G&A | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |||||
| X143 | T&M | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 | |||||
| X144 | Profit | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | 1 | $ - 0 | $ - 0 |
Total Indirect Rates $ - 0 Total Indirect Rates $ - 0 Total Indirect Rates $ - 0 Total Indirect Rates $ - 0 Total Indirect Rates $ - 0 $ - 0
| INCENTIVE POOL | |||||||||||||||||
| Sub-CLIN | Description (would need a CLIN for each Option Year) | Qty | Rate | Amount | Qty | Rate | Amount | Qty | Rate | Amount | Qty | Rate | Amount | Qty | Rate | Amount | |
| Year 1 Incentives: Equipment CLIN | |||||||||||||||||
| Year 1 Incentives: Warranty CLIN | |||||||||||||||||
| Total General Requirements | $0.00 | Total General Requirements | $0.00 | Total General Requirements | $0.00 | Total General Requirements | $0.00 | Total General Requirements | $0.00 | $ - 0 | |||||||
| Total Price Per Period | $0.00 | $0.00 | $0.00 | $0.00 | $0.00 | $ - 0 | |||||||||||
| Check | |||||||||||||||||
| ERROR:#REF! |
@SHEYYAB, ALLA S I added an on-demand services section here we will need to work on completing.
My understanding is this line is for on-demand repair services (at least that’s my understanding from ILD spreadsheet). Some of the sub-CLINs here, such as “site work” are covered under civil works. It’s close to impossible to try and break the site work cost out of the civil works CLIN. I recommend renaming the “Civil works” CLIN if on-demand services is the preferred name
&1#&"Times New Roman"&10&K000000SENSITIVE BUT UNCLASSIFIED
Price Justification Price Justification
Assumptions
| Project/Price Assumptions |
| Allowances, Assumptions, Exclusions and Exceptions: |
File details come from the government source that posted it. Updated .