7-H. CMAR McEachern HS Grandstand Replacement, P26040 - S6K486MCEH - Schematic Design - Attachment D.pdf

PDF 3 MB Posted

Attached to
CMAR McEachern HS Grandstand Replacement State and local contract opportunity
Solicitation number
P26040
Issued by
Cobb County, Georgia

About this file

This document is a demolition and renovation package for the McEachern High School Cantrell Stadium's home side concrete bleacher replacement, prepared by Hussey Gay Bell for the Cobb County School District. The project involves the complete demolition of the existing home side concrete bleachers and associated infrastructure at McEachern High School, located at 514 Glover Street in Marietta, Georgia. The scope of work includes removing concrete bleachers, structural supports, ramps, stairs, handrails, and related site elements, while protecting adjacent structures like the existing pressbox, turf field, and surrounding buildings. The project is in the design development stage and is scheduled for completion in 2025.

The renovation plans detail the replacement of the existing bleachers with new anodized aluminum bleachers and accompanying structures. The new design includes concession areas, locker rooms, and support spaces, with careful attention to matching the exterior finishes and colors of surrounding existing buildings. The architectural plans show new EIFS (Exterior Insulation and Finish System) finishes, split-face CMU (Concrete Masonry Unit) walls, and standing seam roofing that will blend with the current architectural style. The project appears to be funded by the Cobb County School District and aims to modernize the stadium facilities while maintaining the existing site's overall character and functionality.

View the file

Other files for this state and local contract opportunity

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DEMOLITION PACKAGE FOR:

C O

P Y

R

IG

H T

R

E P

R O

D U

C T

IO

N

O

F D

R A

W

IN

G S

T h is

D ra w in g i s t h e p ro p e rt y o f H

.G .B

.D

I N

T E

R N

A T

IO

N

A L a n d i s n o t to b e r e p ro d u c e d o r c o p ie d i n w h o le o r in p a rt

It i s n o t to b e u s e d o n a n y o th e r p ro je c t.

D o n o t s c a le d im e n s io n s f ro m p ri n ts p la n s a n d d e ta ils a re n o t a lw a y s d ra w n t o s c a le

U s e d im e n s io n s g iv e n o r c o n s u lt t h e A rc h it e c t fo r fu rt h e r c la ri fi c a ti o n

FOR

VICINITY MAP

SCALE: VMAPSCALE

3100 BRECKINRIDGE BLVD., BUILDING 300, DULUTH, GA 30096 / T:770.923.1600

www.husseygaybell.com

SAVANNAH ATLANTA STATESBORO CHARLESTON COLUMBIA NASHVILLE

HUSSEY GAY BELL

-------, 2025

Established 1958

SITE

COBB COUNTY SHOOL DISTRICT

COBB COUNTY SCHOOL DISTRICT

514 GLOVER STREET, MARIETTA, GA 30060

MCEACHERN HIGH SCHOOL

CANTRELL STADIUM

HOME SIDE CONCRETE BLEACHER DEMOLITION

D E

S

IG

N D

E V

E L

O P

M E

T

EX-F

EX-E

EX-12 EX-13

10 20 30 40 50 40 30 20 10

10 20 30 40 50 40 30 20 10

VISITOR BLEACHERS

NOT IN SCOPE

END ZONE BLEACHERS

NOT IN SCOPE

TOILET

BOOTH

NOT IN SCOPE

PLAY FIELD - PROTECT

NOT IN SCOPE

ALUMNI CENTER - PROTECT

NOT IN SCOPE

WRESTLING FIELD HOUSE

NOT IN SCOPE

COOLING SHED

NOT IN SCOPE

CONCRETE RAMP AND RETAINING

WALL TO BE DEMOLISHED

RETAINING

WALL TO

REMAIN

EXISTING

GATE

EXISTING

MONUMENT SIGN

EXISTING SITE

FENCING

TURF FIELD (PROTECT)

SCHOOL BUILDING

NOT IN SCOPE

SCHOOL BUILDING

NOT IN SCOPE

FIELD HOUSE

NOT IN SCOPE

RESTROOMS/

FIELD HOUSE

NOT IN SCOPE

D1.01

DRAWING NUMBER

DESIGNED DRAWN CHECKED

C O

P Y

R

IG

H T

R

E P

R O

D U

C T

D

R A

W

IN

G S

T h is

D ra w in g i s t h e p ro p e rt y o f H

.G .B

.D

I N

T E

R N

A T

IO

N

A L a n d i s n o t to b e r e p ro d u c e d o r c o p ie d i n w h o le o r in p a rt

It i s n o t to b e u s e d o n a n y o th e r p ro je c t.

D o n o t s c a le d im e n s io n s f ro m p ri n ts p la n s a n d d e ta ils a re n o t a lw a y s d ra w n t o s c a le

U s e d im e n s io n s g iv e n o r c o n s u lt t h e A rc h it e c t fo r fu rt h e r c la ri fi c a ti o n

R E V

IS

IO

N S

D0.01

D E

M O

L

IT

IO

N

S

IT

E P

L A

N

M c E

A C

H E

R N

H

IG

H S

C H

O O

L H

O M

E S

ID

E

C O

N C

R E

T E

B L

E A

C H

E R

R E

P L

A C

E M

E N

T C

O B

B C

O U

N T

Y S

H O

O L D

IS

T

R

IC

T N

E W

M A

C L A

N D

R D

P

O W

D E

R S

P R

IN

G

S

G A

CMC VR CMC

JOB NO. 625 1013 04

08/07/2025

DESIGN DEVELOPMENT

B re ck in ri d g e

B lv d B u il d in g

D u lu th G eo rg ia

.9

.1

D E

M O

L

IT

IO

N

P A

C K

A G

E F

O R

N O

R T

H

1" = 20'-0"

DEMOLITION SITE PLAN

SYMBOL DESCRIPTION

EXISTING WALL/PARTITION TO REMAIN

EXISTING WALL/PARTITION - TO BE REMOVED

EXISTING FRAME, DOOR & HARDWARE TO BE REMOVED

DEMOLITION PLAN LEGEND:

ALL INFORMATION SHOWN IS BASED ON EXISTING RECORD DRAWINGS.

CONTRACTOR TO VERIFY ALL EXISTING FIELD CONDITIONS PRIOR TO BEGINNING ANY DEMOLITION. NOTIFY ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES BETWEEN DRAWINGS AND ACTUAL FIELD CONDITIONS.

1.

GENERAL DEMOLITION NOTES:

REFER TO CIVIL, MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS FOR ADDITIONAL DEMOLITION WORK

REQUIRED.

2.

(THIS SHEET ONLY) ITEMS SHOWN DASHED ON PLAN ARE TO BE REMOVED. (U.N.O.) ANY ITEM ATTACHED TO WALLS BEING REMOVED IS TO BE REMOVED ALSO. COORDINATE WITH OWNER FOR ANY ITEMS TO BE

SALVAGED.

3.

ALL DEMOLITION WORK SHALL COMPLY WITH THE REQUIREMENTS OF THE

2019 EDITION OF NFPA 241, STANDARD FOR SAFEGUARDING CONSTRUCTION,

ALTERATION, AND DEMOLITION OPERATIONS.

4.

ALL EXISTING STRUCTURAL AND STRUCTURAL FIRE PROTECTION TO BE DEMOLISHED OR REMOVED.5.

PROTECT ALL EXISTING ITEMS NOT SHOWN TO BE REMOVED.6.

ALL DEMOLITION & CONSTRUCTION DEBRIS TO BE HAULED OFF SITE AND

LEGALLY DISPOSED OF AT A PERMITTED LOCATION.7.

ERECT DUST CURTAINS AS NECESSARY TO CONFINE ALL DUST & DEBRIS

TO WORK AREAS. THE OWNER SHALL HAVE UNRESTRICTED ACCESS TO ALL

AREAS NOT WITHIN THE WORK AREA.

8.

SEE CIVIL DRAWINGS FOR ADDITIONAL SITE DEMOLITION.9.

SEE PLUMBING DRAWINGS FOR THE EXTENT OF SLAB DEMOLITION

REQUIRED TO FACILITATE THE NEW UNDER SLAB PLUMBING10.

ANY DAMAGE TO THE EXISTING BUILDING OTHER THAN WHAT IS IN THE SCOPE OF WORK FOR THE PROJECT RENOVATION SHALL BE REPAIRED. ALL REPAIRS SHALL MATCH THE EXISTING BUILDINGS CONSTRUCTION AND SHALL BE PERFORMED AS PART OF THE CONTRACT WITHOUT ANY ADDITIONAL

COST TO THE OWNER.

11.

THE EXISTING BUILDING ENVELOPE SHALL BE MAINTAINED IN A WATERTIGHT CONDITION AT ALL TIMES

DURING THE RENOVATION.

12.

EXTREME CARE SHALL BE TAKEN IN REMOVAL OF ELEMENTS OF THE EXISTING BUILDING THAT MIGHT

BE REUSED, RELOCATED, OR RETURNED TO THE OWNER NOT TO DAMAGE THEM.13.

WHERE DEMOLITION OCCURS, ALL UNUSED DUCTWORK, HANGERS, ANCHOR SUPPORTS, OUTLETS,

ETC., ARE TO BE REMOVED COMPLETELY.14.

ASSIGN THE WORK OF MOVING, REMOVAL, AND CUTTING TO TRADES QUALIFIED TO PERFORM THE

WORK IN A MANNER TO CAUSE THE LEAST DAMAGE TO EACH TYPE OF WORK.

15.

THE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL EXISTING LOW VOLTAGE, ELECTRICAL, PLUMBING AND MECHANICAL LINES BEFORE COMMENCING WORK. CARE SHALL BE TAKEN TO

PROTECT ALL OF THESE EXISTING LINES BEFORE ANY DEMOLITION WORK STARTS.

16.

THE CONTRACTOR IS RESPONSIBLE FOR ALL TEMPORARY CONSTRUCTION AND ALL STAGING,

SCHEDULING, MATERIAL DELIVERIES AND OTHER ITEMS THAT AFFECT THE SEQUENCE OF

CONSTRUCTION OR SCHEDULING THE CONSTRUCTION PROJECT.

17.

DO NOT SCALE DRAWINGS. IF DIMENSIONS ARE IN QUESTION, THE CONTRACTOR SHALL BE

RESPONSIBLE FOR OBTAINING CLARIFICATION FROM THE ARCHITECT BEFORE CONTINUING WITH

CONSTRUCTION.

18.

ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH ALL FEDERAL, STATE AND LOCAL CODES AND

REGULATIONS.

19.

FIELD VERIFY ALL EXISTING CONDITIONS, INCLUDING ITEMS TO REMAIN OR TO BE REMOVED.

DRAWINGS SHOW AS MANY ITEMS AS POSSIBLE FOR REFERENCE ONLY AND ARE NOT INTENDED TO

COMPLETELY REPRESENT ALL EXISTING CONDITIONS.

20.

ANY UTILITY SYSTEMS REQUIRED TO BE ACTIVE FOR USE OF THE EXISTING FACILITY SHALL REMAIN ACTIVE DURING THE COURSE OF THIS WORK. ANY INTERRUPTION OF SERVICES THAT NEEDS TO

HAPPEN SHALL BE CLOSELY COORDINATED WITH THE OWNER.

21.

THE OWNER RESERVES THE RIGHT TO SALVAGE ANY ITEMS REMOVED.22.

PATCH ALL ROOF/WALLS WHERE VENTS, PIPING, ETC. ARE REMOVED WITH IDENTICAL ADJACENT WALL

/ ROOF MATERIAL. CMU OR BRICK SHALL BE 'TOOTHED IN' TO EXISTING

23.

PROTECT ALL EXISTING TREES AND SHRUBBERY/LANDSCAPE DURING CONSTRUCTION SO THAT NO

DAMAGE WILL OCCUR.

24.

PROTECT ALL EXISTING ITEMS AND SERVICES TO REMAIN. REPLACE ANY ITEMS DAMAGED DURING

CONSTRUCTION AT THE GENERAL CONTRACTOR'S EXPENSE.

25.

DEMOLITION KEYED NOTES:

DEMO ALL EXISTING CMU WALLS

REMOVE ALL EXISTING EQUIPMENTS IN KITCHEN. COORDINATE WITH OWNER TO SALVAGE/ REUSE.

REMOVE EXISTING DOORS, DOOR FRAMES AND COIL OVERHEAD DOORS

THESE NOTES ARE NOT ALL INCLUSIVE. ALL DEMOLITION OF EXISTING BUILDING COMPONENTS SHALL BE

INCLUDED AND PERFORMED AS NEEDED TO COMPLETE NEW WORK.

ALL INFORMATION SHOWN IS BASED ON EXISTING RECORD DRAWINGS. CONTRACTOR TO VERIFY ALL EXISTING FIELD CONDITIONS PRIOR TO BEGINNING ANY DEMOLITION. NOTIFY ARCHITECT IMMEDIATELY OF ANY

DISCREPANCIES BETWEEN DRAWINGS AND ACTUAL FIELD CONDITIONS.

D-1

D-2

D-3

REMOVE ALL EXISTING CEILING, LIGHT FIXTURE, CEILING HEATERS AND GRILLES / DUCTWORK

D-4

REMOVE ALL EXISTING RESTROOM PARTITIONS, TOILET, URINALS AND RESTROOM ACCESORIES

D-5

REMOVE ALL EXISTING LOCKERS. COORDINATE WITH OWNER TO SALVAGE/ REUSE.

D-6

DEMO EXISTING STEEL FENCING

D-7

DEMO ALL EXISTING STEEL COLUMNS, BEAMS AND METAL DECKING

REMOVE EXISTING EXTERIOR BRICK VENEER, EIFS FINSH AND SPLIT FACE BLOCK

REMOVE EXISTING STANDING SEAM, GUTTER, DOWNSPOUTS AND METAL COPING

D-8

D-9

D-10

DEMO EXISTING CABINETS

D-11

DEMO EXISTING CONCRETE BLEACHERS AND STRUCTURAL SUPPORTD-12

DEMO EXISTING CONCRETE RAMPS/STAIRSD-13

REMOVE EXISTING HANDRAILS AND GUARDRAILSD-14

PRE-CAST CONCRETE PRESSBOX TO BE DEMOLISHED. PRESSBOX ABOVE TO REMAIN. PROTECT

DURING CONSTRUCTION.

D-15

DEMO EXISTING ROLL UP DOOR D-16

DEMO EXISTING WATER FOUNTAIN D-17

D2.00

D2.00

A2.02

EX-1 EX-2 EX-3 EX-4 EX-5 EX-6 EX-7 EX-8 EX-9 EX-10 EX-11

EX-A

EX-C

EX-B

EX-D

EX-F

EX-E

EX-12 EX-13

D-2

D-13

D-14

D-3

D-1 D-5D-3

D-3

D-3

D-3

D-3D-3D-3 D-3D-3D-3

D-3D-3

D-3

D-3

D-3 D-3

D-3

D-3

D-3

D-3

D-3

D-3

D-3

D-3

D-3

D-3

D-3

D-3

D-3

D-3 D-3

D-3

D-16

D-16

D-5

D-4

D-1

D-2D-2D-2D-2D-2D-2D-2 D-2

D-1

D-1

D-1D-1

D-1

D-1

D-5

D-7 D-5

D-4

D-5

D-7 D-1

D-1

D-1

D-1

D-1

D-1

D-1

D-5

D-7

D-5

D-7

D-5

D-7

D-5 D-7

D-8

D-5

D-8

D-13

D-5

D-7

D-6

D-5

D-6

D-7

D-7D-7

D-1

D-16 D-16 D-16 D-1

D-1

D-2 D-2 D-2 D-2 D-2

D-2D-2

D-2 D-2 D-2

D-2

D-13 D-14

D-17

D-17

D-2

EXISTING MEN

EXISTING CONCESSIONS EXISTING LADIES

EXISTING STORAGEEXISTING LADIES

EXISTING CONCESSIONS

EXISTING MEN

EXISTING LOCKER

EXISTING

STORAGE EXISTING STORAGE

EXISTING

STORAGE

EXISTING

ELEC.

EXISTING CONCESSIONS

EXISTING TOILET

EXISTING

STORAGE

EXISTING

BOYS

RESTROOM

EXISTING

OFFICE

D-5

D-5

CORRIDOR

EXISTING

BOYS

SHOWER

EXISTING

TOILET

PRESSBOX ABOVE METAL STRUCTURE TO REMAIN.

PROTECT DURING CONSTRUCTION

PRESSBOX METAL STRUCTURE TO REMAIN.

PROTECT DURING CONSTRUCTION

EXISTING LADIES

EXISTING OFFICE

EXISTING

TOILET

EXISTING

STORAGE

D-12 D-12 D-12 D-12 D-12 D-12

EXISTING STAIRS TO REMAIN

EXISTING RAMP TO REMAIN

D-2D-2 D-2

DRAWING NUMBER

DESIGNED DRAWN CHECKED

C O

P Y

R

IG

H T

R

E P

R O

D U

C T

D

R A

W

IN

G S

T h is

D ra w in g i s t h e p ro p e rt y o f H

.G .B

.D

I N

T E

R N

A T

IO

N

A L a n d i s n o t to b e r e p ro d u c e d o r c o p ie d i n w h o le o r in p a rt

It i s n o t to b e u s e d o n a n y o th e r p ro je c t.

D o n o t s c a le d im e n s io n s f ro m p ri n ts p la n s a n d d e ta ils a re n o t a lw a y s d ra w n t o s c a le

U s e d im e n s io n s g iv e n o r c o n s u lt t h e A rc h it e c t fo r fu rt h e r c la ri fi c a ti o n

R E V

IS

IO

N S

D1.00

D E

M O

L

IT

IO

N

L O

W E

R L

E V

E L

P L

A N

M c E

A C

H E

R N

H

IG

H S

C H

O O

L H

O M

E S

ID

E

C O

N C

R E

T E

B L

E A

C H

E R

R E

P L

A C

E M

E N

T C

O B

B C

O U

N T

Y S

H O

O L D

IS

T

R

IC

T N

E W

M A

C L A

N D

R D

P

O W

D E

R S

P R

IN

G

S

G A

CMC VR CMC

JOB NO. 625 1013 04

08/07/2025

DESIGN DEVELOPMENT

B re ck in ri d g e

B lv d B u il d in g

D u lu th G eo rg ia

.9

.1

D E

M O

L

IT

IO

N

P A

C K

A G

E F

O R

N O

R T

H

3/32" = 1'-0"

LOWER LEVEL - DEMOLITION

ALL INFORMATION SHOWN IS BASED ON EXISTING RECORD DRAWINGS.

CONTRACTOR TO VERIFY ALL EXISTING FIELD CONDITIONS PRIOR TO BEGINNING ANY DEMOLITION. NOTIFY ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES BETWEEN DRAWINGS AND ACTUAL FIELD CONDITIONS.

1.

GENERAL DEMOLITION NOTES:

REFER TO CIVIL, MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS FOR ADDITIONAL DEMOLITION WORK

REQUIRED.

2.

(THIS SHEET ONLY) ITEMS SHOWN DASHED ON PLAN ARE TO BE REMOVED. (U.N.O.) ANY ITEM ATTACHED TO WALLS BEING REMOVED IS TO BE REMOVED ALSO. COORDINATE WITH OWNER FOR ANY ITEMS TO BE

SALVAGED.

3.

ALL DEMOLITION WORK SHALL COMPLY WITH THE REQUIREMENTS OF THE

2019 EDITION OF NFPA 241, STANDARD FOR SAFEGUARDING CONSTRUCTION,

ALTERATION, AND DEMOLITION OPERATIONS.

4.

ALL EXISTING STRUCTURAL AND STRUCTURAL FIRE PROTECTION TO BE DEMOLISHED OR REMOVED.5.

PROTECT ALL EXISTING ITEMS NOT SHOWN TO BE REMOVED.6.

ALL DEMOLITION & CONSTRUCTION DEBRIS TO BE HAULED OFF SITE AND

LEGALLY DISPOSED OF AT A PERMITTED LOCATION.7.

ERECT DUST CURTAINS AS NECESSARY TO CONFINE ALL DUST & DEBRIS

TO WORK AREAS. THE OWNER SHALL HAVE UNRESTRICTED ACCESS TO ALL

AREAS NOT WITHIN THE WORK AREA.

8.

SEE CIVIL DRAWINGS FOR ADDITIONAL SITE DEMOLITION.9.

SEE PLUMBING DRAWINGS FOR THE EXTENT OF SLAB DEMOLITION

REQUIRED TO FACILITATE THE NEW UNDER SLAB PLUMBING10.

ANY DAMAGE TO THE EXISTING BUILDING OTHER THAN WHAT IS IN THE SCOPE OF WORK FOR THE PROJECT RENOVATION SHALL BE REPAIRED. ALL REPAIRS SHALL MATCH THE EXISTING BUILDINGS CONSTRUCTION AND SHALL BE PERFORMED AS PART OF THE CONTRACT WITHOUT ANY ADDITIONAL

COST TO THE OWNER.

11.

THE EXISTING BUILDING ENVELOPE SHALL BE MAINTAINED IN A WATERTIGHT CONDITION AT ALL TIMES

DURING THE RENOVATION.

12.

EXTREME CARE SHALL BE TAKEN IN REMOVAL OF ELEMENTS OF THE EXISTING BUILDING THAT MIGHT

BE REUSED, RELOCATED, OR RETURNED TO THE OWNER NOT TO DAMAGE THEM.13.

WHERE DEMOLITION OCCURS, ALL UNUSED DUCTWORK, HANGERS, ANCHOR SUPPORTS, OUTLETS,

ETC., ARE TO BE REMOVED COMPLETELY.14.

ASSIGN THE WORK OF MOVING, REMOVAL, AND CUTTING TO TRADES QUALIFIED TO PERFORM THE

WORK IN A MANNER TO CAUSE THE LEAST DAMAGE TO EACH TYPE OF WORK.

15.

THE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL EXISTING LOW VOLTAGE, ELECTRICAL, PLUMBING AND MECHANICAL LINES BEFORE COMMENCING WORK. CARE SHALL BE TAKEN TO

PROTECT ALL OF THESE EXISTING LINES BEFORE ANY DEMOLITION WORK STARTS.

16.

THE CONTRACTOR IS RESPONSIBLE FOR ALL TEMPORARY CONSTRUCTION AND ALL STAGING,

SCHEDULING, MATERIAL DELIVERIES AND OTHER ITEMS THAT AFFECT THE SEQUENCE OF

CONSTRUCTION OR SCHEDULING THE CONSTRUCTION PROJECT.

17.

DO NOT SCALE DRAWINGS. IF DIMENSIONS ARE IN QUESTION, THE CONTRACTOR SHALL BE

RESPONSIBLE FOR OBTAINING CLARIFICATION FROM THE ARCHITECT BEFORE CONTINUING WITH

CONSTRUCTION.

18.

ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH ALL FEDERAL, STATE AND LOCAL CODES AND

REGULATIONS.

19.

FIELD VERIFY ALL EXISTING CONDITIONS, INCLUDING ITEMS TO REMAIN OR TO BE REMOVED.

DRAWINGS SHOW AS MANY ITEMS AS POSSIBLE FOR REFERENCE ONLY AND ARE NOT INTENDED TO

COMPLETELY REPRESENT ALL EXISTING CONDITIONS.

20.

ANY UTILITY SYSTEMS REQUIRED TO BE ACTIVE FOR USE OF THE EXISTING FACILITY SHALL REMAIN ACTIVE DURING THE COURSE OF THIS WORK. ANY INTERRUPTION OF SERVICES THAT NEEDS TO

HAPPEN SHALL BE CLOSELY COORDINATED WITH THE OWNER.

21.

THE OWNER RESERVES THE RIGHT TO SALVAGE ANY ITEMS REMOVED.22.

PATCH ALL ROOF/WALLS WHERE VENTS, PIPING, ETC. ARE REMOVED WITH IDENTICAL ADJACENT WALL

/ ROOF MATERIAL. CMU OR BRICK SHALL BE 'TOOTHED IN' TO EXISTING

23.

PROTECT ALL EXISTING TREES AND SHRUBBERY/LANDSCAPE DURING CONSTRUCTION SO THAT NO

DAMAGE WILL OCCUR.

24.

PROTECT ALL EXISTING ITEMS AND SERVICES TO REMAIN. REPLACE ANY ITEMS DAMAGED DURING

CONSTRUCTION AT THE GENERAL CONTRACTOR'S EXPENSE.

25.

SYMBOL DESCRIPTION

EXISTING WALL/PARTITION TO REMAIN

EXISTING WALL/PARTITION - TO BE REMOVED

EXISTING FRAME, DOOR & HARDWARE TO BE REMOVED

DEMOLITION PLAN LEGEND:

DEMOLITION KEYED NOTES:

DEMO ALL EXISTING CMU WALLS

REMOVE ALL EXISTING EQUIPMENTS IN KITCHEN. COORDINATE WITH OWNER TO SALVAGE/ REUSE.

REMOVE EXISTING DOORS, DOOR FRAMES AND COIL OVERHEAD DOORS

THESE NOTES ARE NOT ALL INCLUSIVE. ALL DEMOLITION OF EXISTING BUILDING COMPONENTS SHALL BE

INCLUDED AND PERFORMED AS NEEDED TO COMPLETE NEW WORK.

ALL INFORMATION SHOWN IS BASED ON EXISTING RECORD DRAWINGS. CONTRACTOR TO VERIFY ALL EXISTING FIELD CONDITIONS PRIOR TO BEGINNING ANY DEMOLITION. NOTIFY ARCHITECT IMMEDIATELY OF ANY

DISCREPANCIES BETWEEN DRAWINGS AND ACTUAL FIELD CONDITIONS.

D-1

D-2

D-3

REMOVE ALL EXISTING CEILING, LIGHT FIXTURE, CEILING HEATERS AND GRILLES / DUCTWORK

D-4

REMOVE ALL EXISTING RESTROOM PARTITIONS, TOILET, URINALS AND RESTROOM ACCESORIES

D-5

REMOVE ALL EXISTING LOCKERS. COORDINATE WITH OWNER TO SALVAGE/ REUSE.

D-6

DEMO EXISTING STEEL FENCING

D-7

DEMO ALL EXISTING STEEL COLUMNS, BEAMS AND METAL DECKING

REMOVE EXISTING EXTERIOR BRICK VENEER, EIFS FINSH AND SPLIT FACE BLOCK

REMOVE EXISTING STANDING SEAM, GUTTER, DOWNSPOUTS AND METAL COPING

D-8

D-9

D-10

DEMO EXISTING CABINETS

D-11

DEMO EXISTING CONCRETE BLEACHERS AND STRUCTURAL SUPPORTD-12

DEMO EXISTING CONCRETE RAMPS/STAIRSD-13

REMOVE EXISTING HANDRAILS AND GUARDRAILSD-14

PRE-CAST CONCRETE PRESSBOX TO BE DEMOLISHED. PRESSBOX ABOVE TO REMAIN. PROTECT

DURING CONSTRUCTION.

D-15

DEMO EXISTING ROLL UP DOOR D-16

DEMO EXISTING WATER FOUNTAIN D-17

D2.00

D2.00

A2.02

EX-1 EX-2 EX-3 EX-4 EX-5 EX-6 EX-7 EX-8 EX-9 EX-10 EX-11

EX-A

EX-C

EX-B

EX-D

EX-F

EX-E

EX-12 EX-13

D-12 D-12 D-12 D-12 D-12D-14 D-14 D-14 D-14 D-14D-12 D-14 D-14

OPEN BELOW

EXISTING MEN

RESTROOM

D-11D-11D-11D-11

D-10

TYP.

D-10

TYP.

D-10

TYP.

D-10

TYP.

D-10

TYP.

D-10

TYP.

D-10

TYP.

D-10

TYP.

D-10

TYP. D-13D-13D-13

D-11

D-10 D-10

D-2

TYP.

D-2 D-2

TYP.

D-2

TYP.

D-2

D-2

TYP.

D-2

TYP.

D-2

TYP.

D-1 D-1

TYP.

TYP.

D-11

D-11D-11

D-10

D-1

D-2

D-2

D-11

D-11

D-11

D-11 D-10

D-10OPEN

BELOW

PRESSBOX ABOVE METAL STRUCTURE TO REMAIN.

PROTECT DURING CONSTRUCTION

PRESSBOX METAL STRUCTURE TO REMAIN.

PROTECT DURING CONSTRUCTION

D-14

D-13

D-14

D-9

D-13

D-14 TYP.

D-2

TYP.

D-2

D-13 D-9 D-9 D-9

D-2

D-14

EXISTING STAIRS TO REMAIN

EXISTING RAMP TO REMAIN

EXISTING CONCESSION

EXISTING WOMEN

RESTROOM

D-5 D-7

D-4

D-16 D-16

D-5 D-7

DRAWING NUMBER

DESIGNED DRAWN CHECKED

C O

P Y

R

IG

H T

R

E P

R O

D U

C T

D

R A

W

IN

G S

T h is

D ra w in g i s t h e p ro p e rt y o f H

.G .B

.D

I N

T E

R N

A T

IO

N

A L a n d i s n o t to b e r e p ro d u c e d o r c o p ie d i n w h o le o r in p a rt

It i s n o t to b e u s e d o n a n y o th e r p ro je c t.

D o n o t s c a le d im e n s io n s f ro m p ri n ts p la n s a n d d e ta ils a re n o t a lw a y s d ra w n t o s c a le

U s e d im e n s io n s g iv e n o r c o n s u lt t h e A rc h it e c t fo r fu rt h e r c la ri fi c a ti o n

R E V

IS

IO

N S

D1.01

D E

M O

L

IT

IO

N

U

P P

E R

L E

V E

L P

L A

N

M c E

A C

H E

R N

H

IG

H S

C H

O O

L H

O M

E S

ID

E

C O

N C

R E

T E

B L

E A

C H

E R

R E

P L

A C

E M

E N

T C

O B

B C

O U

N T

Y S

H O

O L D

IS

T

R

IC

T N

E W

M A

C L A

N D

R D

P

O W

D E

R S

P R

IN

G

S

G A

CMC VR CMC

JOB NO. 625 1013 04

08/07/2025

DESIGN DEVELOPMENT

B re ck in ri d g e

B lv d B u il d in g

D u lu th G eo rg ia

.9

.1

D E

M O

L

IT

IO

N

P A

C K

A G

E F

O R

N O

R T

H

3/32" = 1'-0"

MAIN LEVEL - DEMOLITION

ALL INFORMATION SHOWN IS BASED ON EXISTING RECORD DRAWINGS.

CONTRACTOR TO VERIFY ALL EXISTING FIELD CONDITIONS PRIOR TO BEGINNING ANY DEMOLITION. NOTIFY ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES BETWEEN DRAWINGS AND ACTUAL FIELD CONDITIONS.

1.

GENERAL DEMOLITION NOTES:

REFER TO CIVIL, MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS FOR ADDITIONAL DEMOLITION WORK

REQUIRED.

2.

(THIS SHEET ONLY) ITEMS SHOWN DASHED ON PLAN ARE TO BE REMOVED. (U.N.O.) ANY ITEM ATTACHED TO WALLS BEING REMOVED IS TO BE REMOVED ALSO. COORDINATE WITH OWNER FOR ANY ITEMS TO BE

SALVAGED.

3.

ALL DEMOLITION WORK SHALL COMPLY WITH THE REQUIREMENTS OF THE

2019 EDITION OF NFPA 241, STANDARD FOR SAFEGUARDING CONSTRUCTION,

ALTERATION, AND DEMOLITION OPERATIONS.

4.

ALL EXISTING STRUCTURAL AND STRUCTURAL FIRE PROTECTION TO BE DEMOLISHED OR REMOVED.5.

PROTECT ALL EXISTING ITEMS NOT SHOWN TO BE REMOVED.6.

ALL DEMOLITION & CONSTRUCTION DEBRIS TO BE HAULED OFF SITE AND

LEGALLY DISPOSED OF AT A PERMITTED LOCATION.7.

ERECT DUST CURTAINS AS NECESSARY TO CONFINE ALL DUST & DEBRIS

TO WORK AREAS. THE OWNER SHALL HAVE UNRESTRICTED ACCESS TO ALL

AREAS NOT WITHIN THE WORK AREA.

8.

SEE CIVIL DRAWINGS FOR ADDITIONAL SITE DEMOLITION.9.

SEE PLUMBING DRAWINGS FOR THE EXTENT OF SLAB DEMOLITION

REQUIRED TO FACILITATE THE NEW UNDER SLAB PLUMBING10.

ANY DAMAGE TO THE EXISTING BUILDING OTHER THAN WHAT IS IN THE SCOPE OF WORK FOR THE PROJECT RENOVATION SHALL BE REPAIRED. ALL REPAIRS SHALL MATCH THE EXISTING BUILDINGS CONSTRUCTION AND SHALL BE PERFORMED AS PART OF THE CONTRACT WITHOUT ANY ADDITIONAL

COST TO THE OWNER.

11.

THE EXISTING BUILDING ENVELOPE SHALL BE MAINTAINED IN A WATERTIGHT CONDITION AT ALL TIMES

DURING THE RENOVATION.

12.

EXTREME CARE SHALL BE TAKEN IN REMOVAL OF ELEMENTS OF THE EXISTING BUILDING THAT MIGHT

BE REUSED, RELOCATED, OR RETURNED TO THE OWNER NOT TO DAMAGE THEM.13.

WHERE DEMOLITION OCCURS, ALL UNUSED DUCTWORK, HANGERS, ANCHOR SUPPORTS, OUTLETS,

ETC., ARE TO BE REMOVED COMPLETELY.14.

ASSIGN THE WORK OF MOVING, REMOVAL, AND CUTTING TO TRADES QUALIFIED TO PERFORM THE

WORK IN A MANNER TO CAUSE THE LEAST DAMAGE TO EACH TYPE OF WORK.

15.

THE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL EXISTING LOW VOLTAGE, ELECTRICAL, PLUMBING AND MECHANICAL LINES BEFORE COMMENCING WORK. CARE SHALL BE TAKEN TO

PROTECT ALL OF THESE EXISTING LINES BEFORE ANY DEMOLITION WORK STARTS.

16.

THE CONTRACTOR IS RESPONSIBLE FOR ALL TEMPORARY CONSTRUCTION AND ALL STAGING,

SCHEDULING, MATERIAL DELIVERIES AND OTHER ITEMS THAT AFFECT THE SEQUENCE OF

CONSTRUCTION OR SCHEDULING THE CONSTRUCTION PROJECT.

17.

DO NOT SCALE DRAWINGS. IF DIMENSIONS ARE IN QUESTION, THE CONTRACTOR SHALL BE

RESPONSIBLE FOR OBTAINING CLARIFICATION FROM THE ARCHITECT BEFORE CONTINUING WITH

CONSTRUCTION.

18.

ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH ALL FEDERAL, STATE AND LOCAL CODES AND

REGULATIONS.

19.

FIELD VERIFY ALL EXISTING CONDITIONS, INCLUDING ITEMS TO REMAIN OR TO BE REMOVED.

DRAWINGS SHOW AS MANY ITEMS AS POSSIBLE FOR REFERENCE ONLY AND ARE NOT INTENDED TO

COMPLETELY REPRESENT ALL EXISTING CONDITIONS.

20.

ANY UTILITY SYSTEMS REQUIRED TO BE ACTIVE FOR USE OF THE EXISTING FACILITY SHALL REMAIN ACTIVE DURING THE COURSE OF THIS WORK. ANY INTERRUPTION OF SERVICES THAT NEEDS TO

HAPPEN SHALL BE CLOSELY COORDINATED WITH THE OWNER.

21.

THE OWNER RESERVES THE RIGHT TO SALVAGE ANY ITEMS REMOVED.22.

PATCH ALL ROOF/WALLS WHERE VENTS, PIPING, ETC. ARE REMOVED WITH IDENTICAL ADJACENT WALL

/ ROOF MATERIAL. CMU OR BRICK SHALL BE 'TOOTHED IN' TO EXISTING

23.

PROTECT ALL EXISTING TREES AND SHRUBBERY/LANDSCAPE DURING CONSTRUCTION SO THAT NO

DAMAGE WILL OCCUR.

24.

PROTECT ALL EXISTING ITEMS AND SERVICES TO REMAIN. REPLACE ANY ITEMS DAMAGED DURING

CONSTRUCTION AT THE GENERAL CONTRACTOR'S EXPENSE.

25.

SYMBOL DESCRIPTION

EXISTING WALL/PARTITION TO REMAIN

EXISTING WALL/PARTITION - TO BE REMOVED

EXISTING FRAME, DOOR & HARDWARE TO BE REMOVED

DEMOLITION PLAN LEGEND:

DEMOLITION KEYED NOTES:

DEMO ALL EXISTING CMU WALLS

REMOVE ALL EXISTING EQUIPMENTS IN KITCHEN. COORDINATE WITH OWNER TO SALVAGE/ REUSE.

REMOVE EXISTING DOORS, DOOR FRAMES AND COIL OVERHEAD DOORS

THESE NOTES ARE NOT ALL INCLUSIVE. ALL DEMOLITION OF EXISTING BUILDING COMPONENTS SHALL BE

INCLUDED AND PERFORMED AS NEEDED TO COMPLETE NEW WORK.

ALL INFORMATION SHOWN IS BASED ON EXISTING RECORD DRAWINGS. CONTRACTOR TO VERIFY ALL EXISTING FIELD CONDITIONS PRIOR TO BEGINNING ANY DEMOLITION. NOTIFY ARCHITECT IMMEDIATELY OF ANY

DISCREPANCIES BETWEEN DRAWINGS AND ACTUAL FIELD CONDITIONS.

D-1

D-2

D-3

REMOVE ALL EXISTING CEILING, LIGHT FIXTURE, CEILING HEATERS AND GRILLES / DUCTWORK

D-4

REMOVE ALL EXISTING RESTROOM PARTITIONS, TOILET, URINALS AND RESTROOM ACCESORIES

D-5

REMOVE ALL EXISTING LOCKERS. COORDINATE WITH OWNER TO SALVAGE/ REUSE.

D-6

DEMO EXISTING STEEL FENCING

D-7

DEMO ALL EXISTING STEEL COLUMNS, BEAMS AND METAL DECKING

REMOVE EXISTING EXTERIOR BRICK VENEER, EIFS FINSH AND SPLIT FACE BLOCK

REMOVE EXISTING STANDING SEAM, GUTTER, DOWNSPOUTS AND METAL COPING

D-8

D-9

D-10

DEMO EXISTING CABINETS

D-11

DEMO EXISTING CONCRETE BLEACHERS AND STRUCTURAL SUPPORTD-12

DEMO EXISTING CONCRETE RAMPS/STAIRSD-13

REMOVE EXISTING HANDRAILS AND GUARDRAILSD-14

PRE-CAST CONCRETE PRESSBOX TO BE DEMOLISHED. PRESSBOX ABOVE TO REMAIN. PROTECT

DURING CONSTRUCTION.

D-15

DEMO EXISTING ROLL UP DOOR D-16

DEMO EXISTING WATER FOUNTAIN D-17

D2.00

D2.00

EX-F

EX-E

EX-12 EX-13

D-12D-12D-12D-12D-12D-12

D-14 D-14 D-14 D-14 D-14D-14

PRESSBOX ABOVE METAL STRUCTURE TO REMAIN.

PROTECT DURING CONSTRUCTION

PRESSBOX METAL STRUCTURE BELOW TO REMAIN.

PROTECT DURING CONSTRUCTION

D-15

D-13

D-14

D-1D-1 D-16

DRAWING NUMBER

DESIGNED DRAWN CHECKED

C O

P Y

R

IG

H T

R

E P

R O

D U

C T

D

R A

W

IN

G S

T h is

D ra w in g i s t h e p ro p e rt y o f H

.G .B

.D

I N

T E

R N

A T

IO

N

A L a n d i s n o t to b e r e p ro d u c e d o r c o p ie d i n w h o le o r in p a rt

It i s n o t to b e u s e d o n a n y o th e r p ro je c t.

D o n o t s c a le d im e n s io n s f ro m p ri n ts p la n s a n d d e ta ils a re n o t a lw a y s d ra w n t o s c a le

U s e d im e n s io n s g iv e n o r c o n s u lt t h e A rc h it e c t fo r fu rt h e r c la ri fi c a ti o n

R E V

IS

IO

N S

D1.02

D E

M O

L

IT

IO

N

R

O O

F P

L A

N

M c E

A C

H E

R N

H

IG

H S

C H

O O

L H

O M

E S

ID

E

C O

N C

R E

T E

B L

E A

C H

E R

R E

P L

A C

E M

E N

T C

O B

B C

O U

N T

Y S

H O

O L D

IS

T

R

IC

T N

E W

M A

C L A

N D

R D

P

O W

D E

R S

P R

IN

G

S

G A

CMC VR CMC

JOB NO. 625 1013 04

08/07/2025

DESIGN DEVELOPMENT

B re ck in ri d g e

B lv d B u il d in g

D u lu th G eo rg ia

.9

.1

D E

M O

L

IT

IO

N

P A

C K

A G

E F

O R

N O

R T

H

3/32" = 1'-0"

ROOF PLAN - DEMOLITION

EXISTING STAIR TO REMAIN.

PROTECT DURING CONSTRUCTION

PRESSBOX ABOVE METAL STRUCTURE

TO REMAIN.

PROTECT DURING CONSTRUCTION

D-15

D-12 D-12 D-12

D-13

D-14

D-13

D-14

D-14

D-11

D-12 D-12 D-12D-14 D-14 D-14 D-14 D-14 D-14

D-14

D-10

D-13

D-14

D-13

D-16 D-16D-16D-16

EXISTING PRESSBOX ABOVE METAL

STRUCTURE AND EXISTING BUILDING

TO REMAIN.

PROTECT DURING CONSTRUCTION

PRESSBOX METAL STRUCTURE

BELOW TO REMAIN.

PROTECT DURING CONSTRUCTION

D-13

D-14

D-2

D-9

D-14

D-13D-11

D-2

D-10 D-10

D-14

EXISTING STAIR TO REMAIN.

PROTECT DURING CONSTRUCTION

D-12

D-12

D-15

D-13

D-14

D-13

D-14

D-13

D-14

D-2

D-9

D-14

D-13D-11

D-2

D-10 D-10

D-14

D-12

D-12

D-15

D-13

D-14

D-13

D-14

EXISTING STAIRS AND RAMP TO

REMAIN. PROTECT DURING

CONSTRUCTION

SYMBOL DESCRIPTION

EXISTING WALL/PARTITION TO REMAIN

EXISTING WALL/PARTITION - TO BE REMOVED

EXISTING FRAME, DOOR & HARDWARE TO BE REMOVED

DEMOLITION PLAN LEGEND:

DEMOLITION KEYED NOTES:

DEMO ALL EXISTING CMU WALLS

REMOVE ALL EXISTING EQUIPMENTS IN KITCHEN. COORDINATE WITH OWNER TO SALVAGE/ REUSE.

REMOVE EXISTING DOORS, DOOR FRAMES AND COIL OVERHEAD DOORS

THESE NOTES ARE NOT ALL INCLUSIVE. ALL DEMOLITION OF EXISTING BUILDING COMPONENTS SHALL BE

INCLUDED AND PERFORMED AS NEEDED TO COMPLETE NEW WORK.

ALL INFORMATION SHOWN IS BASED ON EXISTING RECORD DRAWINGS. CONTRACTOR TO VERIFY ALL EXISTING FIELD CONDITIONS PRIOR TO BEGINNING ANY DEMOLITION. NOTIFY ARCHITECT IMMEDIATELY OF ANY

DISCREPANCIES BETWEEN DRAWINGS AND ACTUAL FIELD CONDITIONS.

D-1

D-2

D-3

REMOVE ALL EXISTING CEILING, LIGHT FIXTURE, CEILING HEATERS AND GRILLES / DUCTWORK

D-4

REMOVE ALL EXISTING RESTROOM PARTITIONS, TOILET, URINALS AND RESTROOM ACCESORIES

D-5

REMOVE ALL EXISTING LOCKERS. COORDINATE WITH OWNER TO SALVAGE/ REUSE.

D-6

DEMO EXISTING STEEL FENCING

D-7

DEMO ALL EXISTING STEEL COLUMNS, BEAMS AND METAL DECKING

REMOVE EXISTING EXTERIOR BRICK VENEER, EIFS FINSH AND SPLIT FACE BLOCK

REMOVE EXISTING STANDING SEAM, GUTTER, DOWNSPOUTS AND METAL COPING

D-8

D-9

D-10

DEMO EXISTING CABINETS

D-11

DEMO EXISTING CONCRETE BLEACHERS AND STRUCTURAL SUPPORTD-12

DEMO EXISTING CONCRETE RAMPS/STAIRSD-13

REMOVE EXISTING HANDRAILS AND GUARDRAILSD-14

PRE-CAST CONCRETE PRESSBOX TO BE DEMOLISHED. PRESSBOX ABOVE TO REMAIN. PROTECT

DURING CONSTRUCTION.

D-15

DEMO EXISTING ROLL UP DOOR D-16

DEMO EXISTING WATER FOUNTAIN D-17

ALL INFORMATION SHOWN IS BASED ON EXISTING RECORD DRAWINGS.

CONTRACTOR TO VERIFY ALL EXISTING FIELD CONDITIONS PRIOR TO BEGINNING ANY DEMOLITION. NOTIFY ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES BETWEEN DRAWINGS AND ACTUAL FIELD CONDITIONS.

1.

GENERAL DEMOLITION NOTES:

REFER TO CIVIL, MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS FOR ADDITIONAL DEMOLITION WORK

REQUIRED.

2.

(THIS SHEET ONLY) ITEMS SHOWN DASHED ON PLAN ARE TO BE REMOVED. (U.N.O.) ANY ITEM ATTACHED TO WALLS BEING REMOVED IS TO BE REMOVED ALSO. COORDINATE WITH OWNER FOR ANY ITEMS TO BE

SALVAGED.

3.

ALL DEMOLITION WORK SHALL COMPLY WITH THE REQUIREMENTS OF THE

2019 EDITION OF NFPA 241, STANDARD FOR SAFEGUARDING CONSTRUCTION,

ALTERATION, AND DEMOLITION OPERATIONS.

4.

ALL EXISTING STRUCTURAL AND STRUCTURAL FIRE PROTECTION TO BE DEMOLISHED OR REMOVED.5.

PROTECT ALL EXISTING ITEMS NOT SHOWN TO BE REMOVED.6.

ALL DEMOLITION & CONSTRUCTION DEBRIS TO BE HAULED OFF SITE AND

LEGALLY DISPOSED OF AT A PERMITTED LOCATION.7.

ERECT DUST CURTAINS AS NECESSARY TO CONFINE ALL DUST & DEBRIS

TO WORK AREAS. THE OWNER SHALL HAVE UNRESTRICTED ACCESS TO ALL

AREAS NOT WITHIN THE WORK AREA.

8.

SEE CIVIL DRAWINGS FOR ADDITIONAL SITE DEMOLITION.9.

SEE PLUMBING DRAWINGS FOR THE EXTENT OF SLAB DEMOLITION

REQUIRED TO FACILITATE THE NEW UNDER SLAB PLUMBING10.

ANY DAMAGE TO THE EXISTING BUILDING OTHER THAN WHAT IS IN THE SCOPE OF WORK FOR THE PROJECT RENOVATION SHALL BE REPAIRED. ALL REPAIRS SHALL MATCH THE EXISTING BUILDINGS CONSTRUCTION AND SHALL BE PERFORMED AS PART OF THE CONTRACT WITHOUT ANY ADDITIONAL

COST TO THE OWNER.

11.

THE EXISTING BUILDING ENVELOPE SHALL BE MAINTAINED IN A WATERTIGHT CONDITION AT ALL TIMES

DURING THE RENOVATION.

12.

EXTREME CARE SHALL BE TAKEN IN REMOVAL OF ELEMENTS OF THE EXISTING BUILDING THAT MIGHT

BE REUSED, RELOCATED, OR RETURNED TO THE OWNER NOT TO DAMAGE THEM.13.

WHERE DEMOLITION OCCURS, ALL UNUSED DUCTWORK, HANGERS, ANCHOR SUPPORTS, OUTLETS,

ETC., ARE TO BE REMOVED COMPLETELY.14.

ASSIGN THE WORK OF MOVING, REMOVAL, AND CUTTING TO TRADES QUALIFIED TO PERFORM THE

WORK IN A MANNER TO CAUSE THE LEAST DAMAGE TO EACH TYPE OF WORK.

15.

THE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL EXISTING LOW VOLTAGE, ELECTRICAL, PLUMBING AND MECHANICAL LINES BEFORE COMMENCING WORK. CARE SHALL BE TAKEN TO

PROTECT ALL OF THESE EXISTING LINES BEFORE ANY DEMOLITION WORK STARTS.

16.

THE CONTRACTOR IS RESPONSIBLE FOR ALL TEMPORARY CONSTRUCTION AND ALL STAGING,

SCHEDULING, MATERIAL DELIVERIES AND OTHER ITEMS THAT AFFECT THE SEQUENCE OF

CONSTRUCTION OR SCHEDULING THE CONSTRUCTION PROJECT.

17.

DO NOT SCALE DRAWINGS. IF DIMENSIONS ARE IN QUESTION, THE CONTRACTOR SHALL BE

RESPONSIBLE FOR OBTAINING CLARIFICATION FROM THE ARCHITECT BEFORE CONTINUING WITH

CONSTRUCTION.

18.

ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH ALL FEDERAL, STATE AND LOCAL CODES AND

REGULATIONS.

19.

FIELD VERIFY ALL EXISTING CONDITIONS, INCLUDING ITEMS TO REMAIN OR TO BE REMOVED.

DRAWINGS SHOW AS MANY ITEMS AS POSSIBLE FOR REFERENCE ONLY AND ARE NOT INTENDED TO

COMPLETELY REPRESENT ALL EXISTING CONDITIONS.

20.

ANY UTILITY SYSTEMS REQUIRED TO BE ACTIVE FOR USE OF THE EXISTING FACILITY SHALL REMAIN ACTIVE DURING THE COURSE OF THIS WORK. ANY INTERRUPTION OF SERVICES THAT NEEDS TO

HAPPEN SHALL BE CLOSELY COORDINATED WITH THE OWNER.

21.

THE OWNER RESERVES THE RIGHT TO SALVAGE ANY ITEMS REMOVED.22.

PATCH ALL ROOF/WALLS WHERE VENTS, PIPING, ETC. ARE REMOVED WITH IDENTICAL ADJACENT WALL

/ ROOF MATERIAL. CMU OR BRICK SHALL BE 'TOOTHED IN' TO EXISTING

23.

PROTECT ALL EXISTING TREES AND SHRUBBERY/LANDSCAPE DURING CONSTRUCTION SO THAT NO

DAMAGE WILL OCCUR.

24.

PROTECT ALL EXISTING ITEMS AND SERVICES TO REMAIN. REPLACE ANY ITEMS DAMAGED DURING

CONSTRUCTION AT THE GENERAL CONTRACTOR'S EXPENSE.

25.

DRAWING NUMBER

DESIGNED DRAWN CHECKED

C O

P Y

R

IG

H T

R

E P

R O

D U

C T

D

R A

W

IN

G S

T h is

D ra w in g i s t h e p ro p e rt y o f H

.G .B

.D

I N

T E

R N

A T

IO

N

A L a n d i s n o t to b e r e p ro d u c e d o r c o p ie d i n w h o le o r in p a rt

It i s n o t to b e u s e d o n a n y o th e r p ro je c t.

D o n o t s c a le d im e n s io n s f ro m p ri n ts p la n s a n d d e ta ils a re n o t a lw a y s d ra w n t o s c a le

U s e d im e n s io n s g iv e n o r c o n s u lt t h e A rc h it e c t fo r fu rt h e r c la ri fi c a ti o n

R E V

IS

IO

N S

D2.00

D E

M O

L

IT

IO

N

B

U

IL

D

IN

G E

L E

V A

T

IO

N

M c E

A C

H E

R N

H

IG

H S

C H

O O

L H

O M

E S

ID

E

C O

N C

R E

T E

B L

E A

C H

E R

R E

P L

A C

E M

E N

T C

O B

B C

O U

N T

Y S

H O

O L D

IS

T

R

IC

T N

E W

M A

C L A

N D

R D

P

O W

D E

R S

P R

IN

G

S

G A

CMC VR CMC

JOB NO. 625 1013 04

08/07/2025

DESIGN DEVELOPMENT

B re ck in ri d g e

B lv d B u il d in g

D u lu th G eo rg ia

.9

.1

D E

M O

L

IT

IO

N

P A

C K

A G

E F

O R

3/32" = 1'-0"

BUILDING ELEVATION SOUTH

3/32" = 1'-0"

BUILDING ELEVATION - EAST

RENOVATION OF

C O

P Y

R

IG

H T

R

E P

R O

D U

C T

D

R A

W

IN

G S

T h is

D ra w in g i s t h e p ro p e rt y o f H

.G .B

.D

I N

T E

R N

A T

IO

N

A L a n d i s n o t to b e r e p ro d u c e d o r c o p ie d i n w h o le o r in p a rt

It i s n o t to b e u s e d o n a n y o th e r p ro je c t.

D o n o t s c a le d im e n s io n s f ro m p ri n ts p la n s a n d d e ta ils a re n o t a lw a y s d ra w n t o s c a le

U s e d im e n s io n s g iv e n o r c o n s u lt t h e A rc h it e c t fo r fu rt h e r c la ri fi c a ti o n

FOR

VICINITY MAP

SCALE: VMAPSCALE

3100 BRECKINRIDGE BLVD., BUILDING 300, DULUTH, GA 30096 / T:770.923.1600

www.husseygaybell.com

SAVANNAH ATLANTA STATESBORO CHARLESTON COLUMBIA NASHVILLE

HUSSEY GAY BELL

--, 2025

Established 1958

SITE

COBB COUNTY SHOOL DISTRICT

COBB COUNTY SCHOOL DISTRICT

514 GLOVER STREET, MARIETTA, GA 30060

MCEACHERN HIGH SCHOOL

CANTRELL STADIUM

HOME SIDE CONCRETE BLEACHER REPLACEMENT

D E

S

IG

N D

E V

E L

O P

M E

10 20 30 40 50 40 30 20 10

10 20 30 40 50 40 30 20 10

VISITOR BLEACHERS

NOT IN SCOPE

END ZONE BLEACHERS

NOT IN SCOPE

TOILET

BOOTH

NOT IN SCOPE

PLAY FIELD - PROTECT

NOT IN SCOPE

ALUMNI CENTER - PROTECT

NOT IN SCOPE

WRESTLING FIELD HOUSE

NOT IN SCOPE

COOLING SHED

NOT IN SCOPE

RETAINING

WALL TO

REMAIN

EXISTING

GATE

EXISTING

MONUMENT SIGN

EXISTING SITE

FENCING

TURF FIELD (PROTECT)

SCHOOL BUILDING

NOT IN SCOPE

SCHOOL BUILDING

NOT IN SCOPE

FIELD HOUSE

NOT IN SCOPE

RESTROOMS/

FIELD HOUSE

NOT IN SCOPE

A1.00

DRAWING NUMBER

DESIGNED DRAWN CHECKED

C O

P Y

R

IG

H T

R

E P

R O

D U

C T

D

R A

W

IN

G S

T h is

D ra w in g i s t h e p ro p e rt y o f H

.G .B

.D

I N

T E

R N

A T

IO

N

A L a n d i s n o t to b e r e p ro d u c e d o r c o p ie d i n w h o le o r in p a rt

It i s n o t to b e u s e d o n a n y o th e r p ro je c t.

D o n o t s c a le d im e n s io n s f ro m p ri n ts p la n s a n d d e ta ils a re n o t a lw a y s d ra w n t o s c a le

U s e d im e n s io n s g iv e n o r c o n s u lt t h e A rc h it e c t fo r fu rt h e r c la ri fi c a ti o n

R E V

IS

IO

N S

A0.01

A R

C H

IT

E

C T

U R

A L S

IT

E

P L

A N

M c E

A C

H E

R N

H

IG

H S

C H

O O

L H

O M

E S

ID

E

C O

N C

R E

T E

B L

E A

C H

E R

R E

P L

A C

E M

E N

T C

O B

B C

O U

N T

Y S

H O

O L D

IS

T

R

IC

T N

E W

M A

C L A

N D

R D

P

O W

D E

R S

P R

IN

G

S

G A

CMC VR CMC

JOB NO. 625 1013 04

08/07/2025

DESIGN DEVELOPMENT

B re ck in ri d g e

B lv d B u il d in g

D u lu th G eo rg ia

.9

.1

R E

N O

V A

T

IO

N F

O R

N O

R T

H

1" = 20'-0"

ARCHITECTURAL SITE PLAN

UP

EX-F

EX-E

EX-12 EX-13

658 SF

TEAM ROOM

73 SF

MEN

73 SF

WOMEN

59 SF

MECH.

73 SF

WOMEN

420 SF

CONCESSION

73 SF

MEN

160 SF

STORAGE

126 SF

MECH.

548 SF

MEN

894 SF

WOMEN

84 SF

CUSTODIAL

894 SF

WOMEN

548 SF

MEN

84 SF

CUSTODIAL

PLAZA AREA

NON-HAZARDOUS STORAGE

SERVICE ONLY AREA

(NO STORAGE)

UP

UP

UP

UP

UP

UP

DRAWING NUMBER

DESIGNED DRAWN CHECKED

C O

P Y

R

IG

H T

R

E P

R O

D U

C T

D

R A

W

IN

G S

T h is

D ra w in g i s t h e p ro p e rt y o f H

.G .B

.D

I N

T E

R N

A T

IO

N

A L a n d i s n o t to b e r e p ro d u c e d o r c o p ie d i n w h o le o r in p a rt

It i s n o t to b e u s e d o n a n y o th e r p ro je c t.

D o n o t s c a le d im e n s io n s f ro m p ri n ts p la n s a n d d e ta ils a re n o t a lw a y s d ra w n t o s c a le

U s e d im e n s io n s g iv e n o r c o n s u lt t h e A rc h it e c t fo r fu rt h e r c la ri fi c a ti o n

R E V

IS

IO

N S

A1.00

M c E

A C

H E

R N

S T

A D

IU

M

R

E N

O V

A T

IO

N

P L

A N

M c E

A C

H E

R N

H

IG

H S

C H

O O

L H

O M

E S

ID

E

C O

N C

R E

T E

B L

E A

C H

E R

R E

P L

A C

E M

E N

T C

O B

B C

O U

N T

Y S

H O

O L D

IS

T

R

IC

T N

E W

M A

C L A

N D

R D

P

O W

D E

R S

P R

IN

G

S

G A

CMC VR CMC

JOB NO. 625 1013 04

08/07/2025

DESIGN DEVELOPMENT

B re ck in ri d g e

B lv d B u il d in g

D u lu th G eo rg ia

.9

.1

R E

N O

V A

T

IO

N F

O R

N O

R T

H

3/32" = 1'-0"

McEACHERN STADIUM -

RENOVATION PLAN

EXISTING PRESSBOX TO REMAIN.

PROTECT DURING CONSTRUCTION

NEW PRESSBOX

NEW ANODIZED ALUMINUM BLEACHERS

STANDING SEAM ROOF.

MATCH COLOR TO

SURROUNDING EXISTING

BUILDING

EIFS FINISH AND SPLIT

FACE CMU. MATCH COLOR

TO SURROUNDING

EXISTING BUILDING

STANDING SEAM ROOF.

MATCH COLOR TO

SURROUNDING EXISTING

BUILDING

EIFS FINISH AND SPLIT

FACE CMU. MATCH COLOR

TO SURROUNDING

EXISTING BUILDING

STANDING SEAM ROOF.

MATCH COLOR TO

SURROUNDING EXISTING

BUILDING

EIFS FINISH AND SPLIT

FACE CMU. MATCH COLOR

TO SURROUNDING

EXISTING BUILDING

STANDING SEAM ROOF.

MATCH COLOR TO

SURROUNDING EXISTING

BUILDING

EIFS FINISH AND SPLIT

FACE CMU. MATCH COLOR

TO SURROUNDING

EXISTING BUILDING

DRAWING NUMBER

DESIGNED DRAWN CHECKED

C O

P Y

R

IG

H T

R

E P

R O

D U

C T

D

R A

W

IN

G S

T h is

D ra w in g i s t h e p ro p e rt y o f H

.G .B

.D

I N

T E

R N

A T

IO

N

A L a n d i s n o t to b e r e p ro d u c e d o r c o p ie d i n w h o le o r in p a rt

It i s n o t to b e u s e d o n a n y o th e r p ro je c t.

D o n o t s c a le d im e n s io n s f ro m p ri n ts p la n s a n d d e ta ils a re n o t a lw a y s d ra w n t o s c a le

U s e d im e n s io n s g iv e n o r c o n s u lt t h e A rc h it e c t fo r fu rt h e r c la ri fi c a ti o n

R E V

IS

IO

N S

A2.00

B U

IL

D

IN

G

E L E

V A

T

IO

N

M c E

A C

H E

R N

H

IG

H S

C H

O O

L H

O M

E S

ID

E

C O

N C

R E

T E

B L

E A

C H

E R

R E

P L

A C

E M

E N

T C

O B

B C

O U

N T

Y S

H O

O L D

IS

T

R

IC

T N

E W

M A

C L A

N D

R D

P

O W

D E

R S

P R

IN

G

S

G A

CMC VR CMC

JOB NO. 625 1013 04

DESIGN DEVELOPMENT

B re ck in ri d g e

B lv d B u il d in g

D u lu th G eo rg ia

.9

.1

R E

N O

V A

T

IO

N F

O R

1/8" = 1'-0"

FRONT ELEVATION - STADIUM

BLEACHERS

1/8" = 1'-0"

ELEVATION A - CONCESSION

1/8" = 1'-0"

ELEVATION B - CONCESSION

1/8" = 1'-0"

ELEVATION A - LOCKER ROOM

1/8" = 1'-0"

ELEVATION B - LOCKER ROOM

McEachern Stadium_Existing BLDG-DEMO PACKAGE_R25 - Sheet - G0-00 - COVER SHEET
McEachern Stadium_Existing BLDG-DEMO PACKAGE_R25 - Sheet - D0-01 - DEMOLITION SITE PLAN
McEachern Stadium_Existing BLDG-DEMO PACKAGE_R25 - Sheet - D1-00 - DEMOLITION - LOWER LEVEL PLAN
McEachern Stadium_Existing BLDG-DEMO PACKAGE_R25 - Sheet - D1-01 - DEMOLITION - UPPER LEVEL PLAN
McEachern Stadium_Existing BLDG-DEMO PACKAGE_R25 - Sheet - D1-02 - DEMOLITION - ROOF PLAN
McEachern Stadium_Existing BLDG-DEMO PACKAGE_R25 - Sheet - D2-00 - DEMOLITION - BUILDING ELEVATION

File details come from the government source that posted it. Updated .