Appleton Crane Cert Mary Ann at BSY 12.23.25.pdf
PDF 805 KB Posted
- Attached to
- SBRF Crane Load Moment Indicator System
- Solicitation number
- 6991PE26Q000009
About this file
This is a Telescopic Boom Dock Crane Inspection Report and Certificate of Unit Test and Examination for a Ship Mounted Telescopic Boom Swing Cab crane located at Bay Ship & Yacht in Alameda, California.
The inspection covers a Marry Ann Appleton 60k Telescope Crane (Manufacturer: Appleton, Model: EB190-80-40, Serial: 11213) with a rated capacity of 60,000 lbs. The device is owned by Bay Ship & Yacht and identified as YFS 65 Mary Ann. The inspection was conducted on 12/23/2025 at 8001 Oakport St, Oakland, CA 94621, with the current California Annual certification expiring 12/23/2026. The inspection determined two priorities: one medium-level finding related to paint condition and corrosion control (with a recommendation for periodic corrosion control due to the crane's maritime environment) and one good-level finding. The examination included 122 inspection points covering general requirements, cab systems, operator's station, load chart, power plant, boom system, safety devices, rotating structure, wire rope, load block and hook systems, operational testing, and load testing. Key findings included a lift cylinder showing signs of a leak (Recommendation – Item 44) and missing wire rope clips that were subsequently resolved on 12/23/2025. The no-load operational test results indicated the crane operates as designed. Load testing was performed at a 20-foot radius with a boom angle of 58.5 degrees, 42-foot boom length, and 6 parts of line, achieving a proof load of 33,165 lbs against a rated load of 34,300 lbs (97% of rated load), with the boom directed over the rear and no outriggers deployed. The inspection was completed by Surveyor Joseph Bailey, and the California State Certificate of Unit Test and Examination (Certificate #20251224a) was issued, confirming compliance with Title 8 sections 1613, 4884, 5021, 5022, 5023, and 5024 of the Division of Occupational Safety and Health Administration requirements.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 6991PE26Q000009 QandAs 09.03.26.pdf | ||
| 6991PE26Q000009 QandAs 08.27.26.pdf | ||
| 6991PE26Q000009 Price Sheet.xlsx | XLSX spreadsheet | |
| FAR Deviation Text.pdf | ||
| 6991PE26Q000009 SOW 08.20.26.pdf | ||
| 6991PE26Q000009 Combined Synopsis Solicitation.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Container/Port & Ship Cranes
Location: 2900 Main St Alameda CA
Serial Number: 11213
QR Code: 19606
Description:Marry Ann Appleton 60k Telescope Crane
Manufacturer: Appleton
Model Number: EB190-80-40
Capacity: 60,000 lbs
Device Type: Ship Mounted Telescopic Boom Swing Cab
Owners ID: YFS 65 Mary Ann
Cab: Yes
Total Lift: N/A
Aux Winch: No
Aux Winch 2: No
Jib: No
Lift Above Traveling Rail: N/A
Lift Below Traveling Rail: N/A
Outreach Ship Side: N/A
Outreach Dock Side: N/A
Telescopic Boom Dock Crane Inspection Bay Ship & Yacht 2900 Main Street #2100 Alameda, CA 94501
FolderID: JB1718 FormID: 27084699
Priorities Found: 2 - Medium 120 - Good
INFORMATION
1. Type of Inspection California Annual
2. Location of Test
8001 Oakport St, Oakland, CA 94621
3. Current Annual Expires 3/5/26 P4
GENERAL REQUIREMENTS
4. Inspection Records Satisfactory
5. Sheet Metal Satisfactory
6. Guards / Covers Satisfactory
7. Housekeeping Satisfactory
8. Safety / Warning Decals & Labels Satisfactory
9. Hand Signal Chart Satisfactory
10. Paint Condition / Corrosion Control Recommendation
The crane lives at sea. Should conduct periodic corrosion control as needed
11. External Lights Satisfactory
12. Manufacturers ID Plate Satisfactory P17
CAB
13. Glass Satisfactory
14. Door Restraint Satisfactory
15. Accelerator / Throttle Control Satisfactory
16. Windshield Wipers Satisfactory
17. Mirrors Satisfactory
18. Seat Satisfactory
Page 1 of 7Printed on 1/15/2026
Doc Bailey Construction Equipment disclaims all warranties, both express and implied, relating to the information, reports, opinions and analysis disclosed to the Customer by Doc Bailey Construction Equipment. Doc Bailey Construction Equipment shall not be liable for any errors or omissions, or any losses, injury or damages arising from the use of such information, reports, opinions and analysis by the Customer.
Powered by INSPECTALL
19. Seat Belt Satisfactory
20. Defroster Satisfactory
21. Windows Satisfactory
OPERATORS STATION
22. Grab Rails / Steps / Platforms Satisfactory
23. Positive Swing Lock Satisfactory
24. Controls Identified Satisfactory P30
25. Switches / Functions Satisfactory
26. Horn Satisfactory
27. Accelerator / Throttle Control Satisfactory
28. Anti-Skid Surface Satisfactory
29. Operator's Manual Satisfactory
Unable to locate the operators manual. Must have a copy with the unit. Also, the LMI manual is missing operational instructions
Resolved: (1/15/2026) - They have the ops manual
30. Controls - Movements / Forces Satisfactory
LOAD CHART
31. Per Configuration Satisfactory P40
32. Durable Satisfactory
33. Legible Satisfactory
34. Visible From Operators Station Satisfactory
35. Secured Satisfactory
POWER PLANT
36. Performance Satisfactory
37. Exhaust System Guards & Insulators Satisfactory
38. Belts / Hoses Satisfactory
39. Moving Parts Guards / Covers / Rotate & Recip Satisfactory
40. Hydraulic Hoses / Tubing / Fittings Satisfactory
41. Hydraulic Fluid Level Satisfactory
42. Structure / Frame Satisfactory
43. Foundation / Stabilizing Components Satisfactory
BOOM SYSTEM
44. Lift Cylinder(s) Recommendation P55
Lift cylinder is showing signs of a leak
45. Boom Rest Satisfactory
46. Hydraulic Hoses / Tubes / Fittings Satisfactory
47. Telescoping Cylinder(s) Satisfactory
48. Holding Device Satisfactory
49. Boom Sections Alignment Satisfactory
50. Wear Pads Satisfactory
51. Boom Hinge Pin Satisfactory
52. Boom Head Section Satisfactory P63
53. Sheave(s) Satisfactory
54. Structure Satisfactory
SAFETY DEVICES / OPERATIONAL AIDS
55. Boom Length Indicator Satisfactory P68
56. Instrument Warning Devices Satisfactory
57. Boom Angle / Radius Indicator Satisfactory
Page 2 of 7Printed on 1/15/2026
Doc Bailey Construction Equipment disclaims all warranties, both express and implied, relating to the information, reports, opinions and analysis disclosed to the Customer by Doc Bailey Construction Equipment. Doc Bailey Construction Equipment shall not be liable for any errors or omissions, or any losses, injury or damages arising from the use of such information, reports, opinions and analysis by the Customer.
58. Load Measurement Indicator Satisfactory P72
59. Anti Two-Block Device Satisfactory P73
60. Crane Level Indicator Satisfactory P74
Need to verify the cab bubble level accurately reflects the barge level
Resolved: (1/15/2026) - Verified
61. Overload Protection Satisfactory
62. Accuracy of the LMI + 2%
ROTATING STRUCTURE
63. Turntable Bearing Satisfactory
64. Turntable Ring Gear Satisfactory
65. Swing Gear Box Satisfactory P84
66. Hydraulic Pump(s) Satisfactory
67. Hydraulic Hoses / Tubes / Fittings Satisfactory
68. Hydraulic Motors Satisfactory
69. Hydraulic Filters Satisfactory
70. Hydraulic Pressure Satisfactory
71. Electrical Wiring Satisfactory
72. Mounting Bolts (Turntable) Satisfactory
73. Main Hoist - Motor / Valves / Lines Satisfactory
74. Main Hoist - Brakes Satisfactory
75. Main Hoist - Spooling Satisfactory
76. Main Hoist - Minimum 2 Rope Wraps Satisfactory
77. Steps / Hand Holds / Platform Satisfactory
78. Frame Satisfactory
79. Counterweight Mounting Satisfactory
80. Counterweight Warning Sign Satisfactory
Need to install counter weight warning decal
Resolved: (1/15/2026) - Done
WIRE ROPE - MAIN HOIST
81. Main Hoist - Size 3/4"
82. Main Hoist - Construction IWRC
83. Main Hoist - Date of Install 12/22/25
84. Main Hoist - Measured Wear Satisfactory
85. Main Hoist - Broken Wires Satisfactory
86. Main Hoist - Rope Damage Satisfactory
87. Main Hoist - Lubrication Satisfactory
88. Main Hoist - End Connectors Satisfactory P109
Missing (3) wire rope clips and the backwards bend should be cleaner
Resolved: (12/23/2025) - (4) new wire rope clips installed and becket was reset. JRB 12/23/25
89. Main Hoist - Status In use
MAIN LOAD BLOCK & HOOK
90. Make RopeBlock P111
91. Rated Capacity 30 tons
92. Hook Tram Measurement 3-3/4"
Throat opening
93. Capacity Marking Satisfactory
94. Weight Marking Satisfactory
965 lbs
Page 3 of 7Printed on 1/15/2026
Doc Bailey Construction Equipment disclaims all warranties, both express and implied, relating to the information, reports, opinions and analysis disclosed to the Customer by Doc Bailey Construction Equipment. Doc Bailey Construction Equipment shall not be liable for any errors or omissions, or any losses, injury or damages arising from the use of such information, reports, opinions and analysis by the Customer.
95. Sheave(s) Satisfactory
96. Safety Latche(s) Satisfactory
97. 0° Hook Bend or Twist Satisfactory
98. 5% Hook Opening or 1/4" Max Satisfactory
99. 10% Hook Wear Max Satisfactory
100. Swivel Satisfactory
101. Bearing Satisfactory
102. Wedge Socket / End Fitting Satisfactory
103. Guards Satisfactory
104. Reeving Satisfactory
NO-LOAD OPERATIONAL TEST
105. Results
Operates as designed
LOAD TEST - MAIN BOOM SHORT RADIUS
106. Boom Length 42'
107. Load Radius 20'
108. Boom Angle 58.5°
109. Parts of Line 6
110. Proof Load 33,165 lbs
111. Rated Load 34,300 lbs
112. Outriggers No
113. Boom Direction
Over Rear
114. % of the Rated Load 97 %
LOAD TEST
115. Configuration
Lifted over the front
116. Description of Test Weights known weights
117. Basis for Load Ratings Per MFG Specs
118. Limitations Imposed
None
119. Results of Load Test (P) Pass
VERIFICATION
120. Inspector Name & Signature Joseph Bailey
121. Customer Name & Signature Customer Was Present But Did Not Sign
122. Date of Inspection 12/23/2025
Page 4 of 7Printed on 1/15/2026
Doc Bailey Construction Equipment disclaims all warranties, both express and implied, relating to the information, reports, opinions and analysis disclosed to the Customer by Doc Bailey Construction Equipment. Doc Bailey Construction Equipment shall not be liable for any errors or omissions, or any losses, injury or damages arising from the use of such information, reports, opinions and analysis by the Customer.
P4.1 P4.2 P17.3 P30.4
P30.5 P40.6 P40.7 P55.8
P55.9 P55.10 P55.11 P63.12
P63.13 P63.14 P63.15 P68.16
Page 5 of 7Printed on 1/15/2026
Doc Bailey Construction Equipment disclaims all warranties, both express and implied, relating to the information, reports, opinions and analysis disclosed to the Customer by Doc Bailey Construction Equipment. Doc Bailey Construction Equipment shall not be liable for any errors or omissions, or any losses, injury or damages arising from the use of such information, reports, opinions and analysis by the Customer.
P68.17 P72.18 P72.19 P73.20
P73.21 P73.22 P74.23 P84.24
P84.25 P109.26 P109.27 P109.28
P111.29 P111.30 P111.31 P111.32
Page 6 of 7Printed on 1/15/2026
Doc Bailey Construction Equipment disclaims all warranties, both express and implied, relating to the information, reports, opinions and analysis disclosed to the Customer by Doc Bailey Construction Equipment. Doc Bailey Construction Equipment shall not be liable for any errors or omissions, or any losses, injury or damages arising from the use of such information, reports, opinions and analysis by the Customer.
P111.33
Page 7 of 7Printed on 1/15/2026
Doc Bailey Construction Equipment disclaims all warranties, both express and implied, relating to the information, reports, opinions and analysis disclosed to the Customer by Doc Bailey Construction Equipment. Doc Bailey Construction Equipment shall not be liable for any errors or omissions, or any losses, injury or damages arising from the use of such information, reports, opinions and analysis by the Customer.
2584 Grant Ave., San Lorenzo, CA 94580 590 Farrington Hwy. #524, PMB 178, Kapolei, HI 96707
5040 Alto Ave., N. Las Vegas, NV 89115
CA 510-638-6243 | HI 808-545-4884 | NV 702-485-1457
Plate V - State of California - Department of Industrial Relations - Division of Occupational Safety & Health
CERTIFICATE OF UNIT TEST AND/OR EXAMINATION OF CRANE, DERRICK, OR OTHER MATERIAL HANDLING DEVICE
OVER 3-TON RATED CAPACITY
OWNER: Bay Ship & Yacht
LOCATION OF TEST: 8001 Oakport St, Oakland, CA 94621
CUSTOMER ADDRESS: 2900 Main Street #2100 Alameda CA, 94501
USAGE LOCATION:
DEVICE TYPE: Ship Mounted Telescopic Boom Swing Cab DESC: Marry Ann Appleton 60k Telescope Crane
RATED CAPACITY: 60,000
lbs
MANUFACTURER: Appleton MODEL: EB190-80-40 SERIAL: 11213
OWNERS IDENTIFICATION: YFS 65 Mary Ann HOURS: hrs MILES: mi
RADIUS PROOF LOAD RATED LOAD OUTRIGGERS / BOOM DIR
MB LONG: /
MB SHORT: 20' 33,165 lbs 34,300 lbs No / Over Rear
CONFIGURATION: Lifted over the front
DESCRIPTION OF TEST WEIGHTS: known weights
BASIS FOR ASSIGNED LOAD: Per MFG Specs
THIS EXAMINATION SHALL COVER THE POINTS LISTED ON THE BACK OF THIS CERTIFICATE.
REMARKS AND/OR LIMITATIONS IMPOSED: None
I certify that on 12/23/2025, the above described device was tested and examined by the undersigned; that said test and examination met the Title 8, section 1613, 4884, 5021, 5022, 5023 and 5024 requirements of the Division of Occupational Safety and Health Administration. That all deficiencies affecting the safe operation of the crane have been corrected prior to the issuance of this certificate; That all requirements on the back of this certificate shall be followed during the time frame this certificate is good. That DBCE Inc has no direct or indirect financial interest in this crane.
THIS CERTIFICATE IS: California Annual
LAST QUADRENNIAL DONE: BY:
ANNUAL EXPIRES: 12/23/2026 CERTIFICATE #: 20251224a
CERTIFICATING AGENCY: Doc Bailey Construction Equipment Inc. DOSH LICENSE #: CA-01 EXPIRES: 03/31/2026
SURVEYOR: Joseph Bailey CATEGORY: All
SIGNATURE:
TITLE: Surveyor
DATE: 12/23/2025
THE EXAMINATION SHALL BE CARRIED OUT IN CONJUNCTION WITH EACH PROOF TEST. THE
QUALIFIED PERSON OR HIS AUTHORIZED REPRESENTATIVE SHALL MAKE A DETERMINATION AS
REQUIREMENTS FOR THE CORRECTION OF DEFICIENCIES FOUND. THE EXAMINATION SHALL
COVER THE FOLLOWING POINTS AS APPLICABLE.
1. All functional operating mechanisms for improper function, maladjustment, and excessive component wear, with particular attention to sheaves, pins, and drums. This shall include operation with partial load, in which all functions and movements, including, where applicable, maximum possible rotation in both directions, are performed.
2. All safety devices for malfunction.
3. Deterioration or leakage in lines, tanks, valves, drains, pumps, and other parts of air or hydraulic systems.
4. Loose gear components, (i.e. hooks, etc.) including wire rope, wire rope terminals and connections, with particular attention to sections of wire rope exposed to abnormal wear and sections not normally exposed for examination.
5. Rope reeving for compliance with certifying agents recommendations.
6. Deformed, cracked, or excessively corroded members in crane structure and boom.
7. Loose bolts, rivets, or other connections.
8. Worn, cracked, or distorted parts affecting safe operation.
9. Excessive wear on and free operation of brake and clutch system parts, linings, pawls, and ratchets.
10. Load, boom angle, or other indicators shall be checked for any significant inaccuracies.
11. It shall be ascertained that there is a durable rating chart visible to the operator, covering the complete range of the certified agents capacity ratings at all operating radii, for all permissible boom lengths and jib lengths, with alternate ratings for optional equipment affecting such ratings. Necessary precautions or warnings shall be included, and operating controls marked, or an explanation of controls shall be posted at the operators position to indicate function.
12. Where used, clamshell buckets or other similar equipment such as magnets, etc, shall be carefully examined in all respect, with particular attention to closing line wires and sheaves.
13. Careful examination of the junction areas of removable boom sections, particularly for proper seating, cracks, deformities, or other defects in securing bolts and in the vicinity of such bolts.
14. It shall be ascertained that no counterweights in excess of the certified agent's specifications are lifted.
15. Such other examinations deemed necessary under the circumstances.
Telescopic Boom Dock Crane Inspection