This is a Telescopic Boom Dock Crane Inspection Report and Certificate of Unit Test and Examination for a Ship Mounted Telescopic Boom Swing Cab crane located at Bay Ship & Yacht in Alameda, California.

The inspection covers a Marry Ann Appleton 60k Telescope Crane (Manufacturer: Appleton, Model: EB190-80-40, Serial: 11213) with a rated capacity of 60,000 lbs. The device is owned by Bay Ship & Yacht and identified as YFS 65 Mary Ann. The inspection was conducted on 12/23/2025 at 8001 Oakport St, Oakland, CA 94621, with the current California Annual certification expiring 12/23/2026. The inspection determined two priorities: one medium-level finding related to paint condition and corrosion control (with a recommendation for periodic corrosion control due to the crane's maritime environment) and one good-level finding. The examination included 122 inspection points covering general requirements, cab systems, operator's station, load chart, power plant, boom system, safety devices, rotating structure, wire rope, load block and hook systems, operational testing, and load testing. Key findings included a lift cylinder showing signs of a leak (Recommendation – Item 44) and missing wire rope clips that were subsequently resolved on 12/23/2025. The no-load operational test results indicated the crane operates as designed. Load testing was performed at a 20-foot radius with a boom angle of 58.5 degrees, 42-foot boom length, and 6 parts of line, achieving a proof load of 33,165 lbs against a rated load of 34,300 lbs (97% of rated load), with the boom directed over the rear and no outriggers deployed. The inspection was completed by Surveyor Joseph Bailey, and the California State Certificate of Unit Test and Examination (Certificate #20251224a) was issued, confirming compliance with Title 8 sections 1613, 4884, 5021, 5022, 5023, and 5024 of the Division of Occupational Safety and Health Administration requirements.

View the file

Other files

File Type Posted
6991PE26Q000009 QandAs 09.03.26.pdf PDF
6991PE26Q000009 QandAs 08.27.26.pdf PDF
6991PE26Q000009 Price Sheet.xlsx XLSX spreadsheet
FAR Deviation Text.pdf PDF
6991PE26Q000009 SOW 08.20.26.pdf PDF
6991PE26Q000009 Combined Synopsis Solicitation.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Container/Port & Ship Cranes

Location: 2900 Main St Alameda CA

Serial Number: 11213

QR Code: 19606

Description:Marry Ann Appleton 60k Telescope Crane

Manufacturer: Appleton

Model Number: EB190-80-40

Capacity: 60,000 lbs

Device Type: Ship Mounted Telescopic Boom Swing Cab

Owners ID: YFS 65 Mary Ann

Cab: Yes

Total Lift: N/A

Aux Winch: No

Aux Winch 2: No

Jib: No

Lift Above Traveling Rail: N/A

Lift Below Traveling Rail: N/A

Outreach Ship Side: N/A

Outreach Dock Side: N/A

Telescopic Boom Dock Crane Inspection Bay Ship & Yacht 2900 Main Street #2100 Alameda, CA 94501

FolderID: JB1718 FormID: 27084699

Priorities Found: 2 - Medium 120 - Good

INFORMATION

1. Type of Inspection California Annual

2. Location of Test

8001 Oakport St, Oakland, CA 94621

3. Current Annual Expires 3/5/26 P4

GENERAL REQUIREMENTS

4. Inspection Records Satisfactory

5. Sheet Metal Satisfactory

6. Guards / Covers Satisfactory

7. Housekeeping Satisfactory

8. Safety / Warning Decals & Labels Satisfactory

9. Hand Signal Chart Satisfactory

10. Paint Condition / Corrosion Control Recommendation

The crane lives at sea. Should conduct periodic corrosion control as needed

11. External Lights Satisfactory

12. Manufacturers ID Plate Satisfactory P17

CAB

13. Glass Satisfactory

14. Door Restraint Satisfactory

15. Accelerator / Throttle Control Satisfactory

16. Windshield Wipers Satisfactory

17. Mirrors Satisfactory

18. Seat Satisfactory

Page 1 of 7Printed on 1/15/2026

Doc Bailey Construction Equipment disclaims all warranties, both express and implied, relating to the information, reports, opinions and analysis disclosed to the Customer by Doc Bailey Construction Equipment. Doc Bailey Construction Equipment shall not be liable for any errors or omissions, or any losses, injury or damages arising from the use of such information, reports, opinions and analysis by the Customer.

Powered by INSPECTALL

19. Seat Belt Satisfactory

20. Defroster Satisfactory

21. Windows Satisfactory

OPERATORS STATION

22. Grab Rails / Steps / Platforms Satisfactory

23. Positive Swing Lock Satisfactory

24. Controls Identified Satisfactory P30

25. Switches / Functions Satisfactory

26. Horn Satisfactory

27. Accelerator / Throttle Control Satisfactory

28. Anti-Skid Surface Satisfactory

29. Operator's Manual Satisfactory

Unable to locate the operators manual. Must have a copy with the unit. Also, the LMI manual is missing operational instructions

Resolved: (1/15/2026) - They have the ops manual

30. Controls - Movements / Forces Satisfactory

LOAD CHART

31. Per Configuration Satisfactory P40

32. Durable Satisfactory

33. Legible Satisfactory

34. Visible From Operators Station Satisfactory

35. Secured Satisfactory

POWER PLANT

36. Performance Satisfactory

37. Exhaust System Guards & Insulators Satisfactory

38. Belts / Hoses Satisfactory

39. Moving Parts Guards / Covers / Rotate & Recip Satisfactory

40. Hydraulic Hoses / Tubing / Fittings Satisfactory

41. Hydraulic Fluid Level Satisfactory

42. Structure / Frame Satisfactory

43. Foundation / Stabilizing Components Satisfactory

BOOM SYSTEM

44. Lift Cylinder(s) Recommendation P55

Lift cylinder is showing signs of a leak

45. Boom Rest Satisfactory

46. Hydraulic Hoses / Tubes / Fittings Satisfactory

47. Telescoping Cylinder(s) Satisfactory

48. Holding Device Satisfactory

49. Boom Sections Alignment Satisfactory

50. Wear Pads Satisfactory

51. Boom Hinge Pin Satisfactory

52. Boom Head Section Satisfactory P63

53. Sheave(s) Satisfactory

54. Structure Satisfactory

SAFETY DEVICES / OPERATIONAL AIDS

55. Boom Length Indicator Satisfactory P68

56. Instrument Warning Devices Satisfactory

57. Boom Angle / Radius Indicator Satisfactory

Page 2 of 7Printed on 1/15/2026

Doc Bailey Construction Equipment disclaims all warranties, both express and implied, relating to the information, reports, opinions and analysis disclosed to the Customer by Doc Bailey Construction Equipment. Doc Bailey Construction Equipment shall not be liable for any errors or omissions, or any losses, injury or damages arising from the use of such information, reports, opinions and analysis by the Customer.

58. Load Measurement Indicator Satisfactory P72

59. Anti Two-Block Device Satisfactory P73

60. Crane Level Indicator Satisfactory P74

Need to verify the cab bubble level accurately reflects the barge level

Resolved: (1/15/2026) - Verified

61. Overload Protection Satisfactory

62. Accuracy of the LMI + 2%

ROTATING STRUCTURE

63. Turntable Bearing Satisfactory

64. Turntable Ring Gear Satisfactory

65. Swing Gear Box Satisfactory P84

66. Hydraulic Pump(s) Satisfactory

67. Hydraulic Hoses / Tubes / Fittings Satisfactory

68. Hydraulic Motors Satisfactory

69. Hydraulic Filters Satisfactory

70. Hydraulic Pressure Satisfactory

71. Electrical Wiring Satisfactory

72. Mounting Bolts (Turntable) Satisfactory

73. Main Hoist - Motor / Valves / Lines Satisfactory

74. Main Hoist - Brakes Satisfactory

75. Main Hoist - Spooling Satisfactory

76. Main Hoist - Minimum 2 Rope Wraps Satisfactory

77. Steps / Hand Holds / Platform Satisfactory

78. Frame Satisfactory

79. Counterweight Mounting Satisfactory

80. Counterweight Warning Sign Satisfactory

Need to install counter weight warning decal

Resolved: (1/15/2026) - Done

WIRE ROPE - MAIN HOIST

81. Main Hoist - Size 3/4"

82. Main Hoist - Construction IWRC

83. Main Hoist - Date of Install 12/22/25

84. Main Hoist - Measured Wear Satisfactory

85. Main Hoist - Broken Wires Satisfactory

86. Main Hoist - Rope Damage Satisfactory

87. Main Hoist - Lubrication Satisfactory

88. Main Hoist - End Connectors Satisfactory P109

Missing (3) wire rope clips and the backwards bend should be cleaner

Resolved: (12/23/2025) - (4) new wire rope clips installed and becket was reset. JRB 12/23/25

89. Main Hoist - Status In use

MAIN LOAD BLOCK & HOOK

90. Make RopeBlock P111

91. Rated Capacity 30 tons

92. Hook Tram Measurement 3-3/4"

Throat opening

93. Capacity Marking Satisfactory

94. Weight Marking Satisfactory

965 lbs

Page 3 of 7Printed on 1/15/2026

Doc Bailey Construction Equipment disclaims all warranties, both express and implied, relating to the information, reports, opinions and analysis disclosed to the Customer by Doc Bailey Construction Equipment. Doc Bailey Construction Equipment shall not be liable for any errors or omissions, or any losses, injury or damages arising from the use of such information, reports, opinions and analysis by the Customer.

95. Sheave(s) Satisfactory

96. Safety Latche(s) Satisfactory

97. 0° Hook Bend or Twist Satisfactory

98. 5% Hook Opening or 1/4" Max Satisfactory

99. 10% Hook Wear Max Satisfactory

100. Swivel Satisfactory

101. Bearing Satisfactory

102. Wedge Socket / End Fitting Satisfactory

103. Guards Satisfactory

104. Reeving Satisfactory

NO-LOAD OPERATIONAL TEST

105. Results

Operates as designed

LOAD TEST - MAIN BOOM SHORT RADIUS

106. Boom Length 42'

107. Load Radius 20'

108. Boom Angle 58.5°

109. Parts of Line 6

110. Proof Load 33,165 lbs

111. Rated Load 34,300 lbs

112. Outriggers No

113. Boom Direction

Over Rear

114. % of the Rated Load 97 %

LOAD TEST

115. Configuration

Lifted over the front

116. Description of Test Weights known weights

117. Basis for Load Ratings Per MFG Specs

118. Limitations Imposed

None

119. Results of Load Test (P) Pass

VERIFICATION

120. Inspector Name & Signature Joseph Bailey

121. Customer Name & Signature Customer Was Present But Did Not Sign

122. Date of Inspection 12/23/2025

Page 4 of 7Printed on 1/15/2026

Doc Bailey Construction Equipment disclaims all warranties, both express and implied, relating to the information, reports, opinions and analysis disclosed to the Customer by Doc Bailey Construction Equipment. Doc Bailey Construction Equipment shall not be liable for any errors or omissions, or any losses, injury or damages arising from the use of such information, reports, opinions and analysis by the Customer.

P4.1 P4.2 P17.3 P30.4

P30.5 P40.6 P40.7 P55.8

P55.9 P55.10 P55.11 P63.12

P63.13 P63.14 P63.15 P68.16

Page 5 of 7Printed on 1/15/2026

Doc Bailey Construction Equipment disclaims all warranties, both express and implied, relating to the information, reports, opinions and analysis disclosed to the Customer by Doc Bailey Construction Equipment. Doc Bailey Construction Equipment shall not be liable for any errors or omissions, or any losses, injury or damages arising from the use of such information, reports, opinions and analysis by the Customer.

P68.17 P72.18 P72.19 P73.20

P73.21 P73.22 P74.23 P84.24

P84.25 P109.26 P109.27 P109.28

P111.29 P111.30 P111.31 P111.32

Page 6 of 7Printed on 1/15/2026

Doc Bailey Construction Equipment disclaims all warranties, both express and implied, relating to the information, reports, opinions and analysis disclosed to the Customer by Doc Bailey Construction Equipment. Doc Bailey Construction Equipment shall not be liable for any errors or omissions, or any losses, injury or damages arising from the use of such information, reports, opinions and analysis by the Customer.

P111.33

Page 7 of 7Printed on 1/15/2026

Doc Bailey Construction Equipment disclaims all warranties, both express and implied, relating to the information, reports, opinions and analysis disclosed to the Customer by Doc Bailey Construction Equipment. Doc Bailey Construction Equipment shall not be liable for any errors or omissions, or any losses, injury or damages arising from the use of such information, reports, opinions and analysis by the Customer.

2584 Grant Ave., San Lorenzo, CA 94580 590 Farrington Hwy. #524, PMB 178, Kapolei, HI 96707

5040 Alto Ave., N. Las Vegas, NV 89115

CA 510-638-6243 | HI 808-545-4884 | NV 702-485-1457

Plate V - State of California - Department of Industrial Relations - Division of Occupational Safety & Health

CERTIFICATE OF UNIT TEST AND/OR EXAMINATION OF CRANE, DERRICK, OR OTHER MATERIAL HANDLING DEVICE

OVER 3-TON RATED CAPACITY

OWNER: Bay Ship & Yacht

LOCATION OF TEST: 8001 Oakport St, Oakland, CA 94621

CUSTOMER ADDRESS: 2900 Main Street #2100 Alameda CA, 94501

USAGE LOCATION:

DEVICE TYPE: Ship Mounted Telescopic Boom Swing Cab DESC: Marry Ann Appleton 60k Telescope Crane

RATED CAPACITY: 60,000

lbs

MANUFACTURER: Appleton MODEL: EB190-80-40 SERIAL: 11213

OWNERS IDENTIFICATION: YFS 65 Mary Ann HOURS: hrs MILES: mi

RADIUS PROOF LOAD RATED LOAD OUTRIGGERS / BOOM DIR

MB LONG: /

MB SHORT: 20' 33,165 lbs 34,300 lbs No / Over Rear

CONFIGURATION: Lifted over the front

DESCRIPTION OF TEST WEIGHTS: known weights

BASIS FOR ASSIGNED LOAD: Per MFG Specs

THIS EXAMINATION SHALL COVER THE POINTS LISTED ON THE BACK OF THIS CERTIFICATE.

REMARKS AND/OR LIMITATIONS IMPOSED: None

I certify that on 12/23/2025, the above described device was tested and examined by the undersigned; that said test and examination met the Title 8, section 1613, 4884, 5021, 5022, 5023 and 5024 requirements of the Division of Occupational Safety and Health Administration. That all deficiencies affecting the safe operation of the crane have been corrected prior to the issuance of this certificate; That all requirements on the back of this certificate shall be followed during the time frame this certificate is good. That DBCE Inc has no direct or indirect financial interest in this crane.

THIS CERTIFICATE IS: California Annual

LAST QUADRENNIAL DONE: BY:

ANNUAL EXPIRES: 12/23/2026 CERTIFICATE #: 20251224a

CERTIFICATING AGENCY: Doc Bailey Construction Equipment Inc. DOSH LICENSE #: CA-01 EXPIRES: 03/31/2026

SURVEYOR: Joseph Bailey CATEGORY: All

SIGNATURE:

TITLE: Surveyor

DATE: 12/23/2025

THE EXAMINATION SHALL BE CARRIED OUT IN CONJUNCTION WITH EACH PROOF TEST. THE

QUALIFIED PERSON OR HIS AUTHORIZED REPRESENTATIVE SHALL MAKE A DETERMINATION AS

REQUIREMENTS FOR THE CORRECTION OF DEFICIENCIES FOUND. THE EXAMINATION SHALL

COVER THE FOLLOWING POINTS AS APPLICABLE.

1. All functional operating mechanisms for improper function, maladjustment, and excessive component wear, with particular attention to sheaves, pins, and drums. This shall include operation with partial load, in which all functions and movements, including, where applicable, maximum possible rotation in both directions, are performed.

2. All safety devices for malfunction.

3. Deterioration or leakage in lines, tanks, valves, drains, pumps, and other parts of air or hydraulic systems.

4. Loose gear components, (i.e. hooks, etc.) including wire rope, wire rope terminals and connections, with particular attention to sections of wire rope exposed to abnormal wear and sections not normally exposed for examination.

5. Rope reeving for compliance with certifying agents recommendations.

6. Deformed, cracked, or excessively corroded members in crane structure and boom.

7. Loose bolts, rivets, or other connections.

8. Worn, cracked, or distorted parts affecting safe operation.

9. Excessive wear on and free operation of brake and clutch system parts, linings, pawls, and ratchets.

10. Load, boom angle, or other indicators shall be checked for any significant inaccuracies.

11. It shall be ascertained that there is a durable rating chart visible to the operator, covering the complete range of the certified agents capacity ratings at all operating radii, for all permissible boom lengths and jib lengths, with alternate ratings for optional equipment affecting such ratings. Necessary precautions or warnings shall be included, and operating controls marked, or an explanation of controls shall be posted at the operators position to indicate function.

12. Where used, clamshell buckets or other similar equipment such as magnets, etc, shall be carefully examined in all respect, with particular attention to closing line wires and sheaves.

13. Careful examination of the junction areas of removable boom sections, particularly for proper seating, cracks, deformities, or other defects in securing bolts and in the vicinity of such bolts.

14. It shall be ascertained that no counterweights in excess of the certified agent's specifications are lifted.

15. Such other examinations deemed necessary under the circumstances.

Telescopic Boom Dock Crane Inspection