This document is a set of building drawings and specifications for a speculative commercial building project located at 3351 Combine Street, Paso Robles, California. The project, developed by Westco Builders Inc., comprises a 4,912 square foot structure with approximately 512 square feet of office space and 4,480 square feet of shop/storage area on a 16,936 square foot parcel. The building is classified as Code Occupancy S1 or F1 (non-sprinkled, V-B construction) with a maximum occupant load of 42 persons.
The architectural drawings include site plans, floor plans, foundation details, elevations, sections, and mechanical/electrical/plumbing layouts. Structural specifications call for 6-inch concrete slab with #4 rebar on 24-inch centers, various foundation embedments with anchoring systems, wood and steel framing components, and standard commercial roofing. The design incorporates three 14-foot by 14-foot roll-up doors for the shop area, office spaces with standard commercial finishes, accessible parking and facilities compliant with ADA requirements, and mechanical systems including a 24K BTU ground-mounted heat pump with supplemental wall-mounted units. Electrical service includes a 200-amp, 120/230-volt, three-phase panel with 10,000 AIC capacity. All work must comply with the 2016 California Building Code, California Fire Code, California Energy Code, and Green Building Standards Code. The project was designed by architect Nick Gilman and dated March 20, 2017.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
6' -8
16'-0"
6.
0'
6.
0'
146.0'
BUILDING AREA 4,912 SF
Parkway Landscaping
'-0
6'
-0
26'-0"
17'-8" 83'-4" 45'-0"
'-4
8'
-8
4'-0"
'-6
'-6
2 Similar
4ʺ th Concrete w/
#3 @ 24ʺ o.c. ea.way
OFFICE
6ʺ th Concrete w/
#4 @ 24ʺ o.c. ea.way
6ʺ t h C o n cr et e w
#4
4ʺ o .c
. e a
.w a y
5' -6
27'-0" 18'-0"
* NOTE :
See also GRADING PLAN Sheet 2
2-1/2ʺ AC on 6ʺ Class II (or Eq.) Base
SHOP / STORAGE
OCCUPANCY F1, F2, S1, S2
9' -0
9'
-0
'-0
4'
-6
8' -0
Asphalt
5ʺ Down = 1.3%6' -8
4ʺ D o w n
.2
ADA PATH OF TRAVEL
'-0
15'-0"4'-6"
Level Area
Blue Paint @
Perimeter & Diagonals
12ʺ White Letters
(1 2ʺ
W h it e
L et te rs
18ʹ ROLLING GATE
8ʹ F
E N
C E
TRASH ENCLOSURE
6ʹ High Chain Link w/ Slats
8ʹ FENCE
8ʹ FENCE
8ʹ F
E N
C E
ʹ G
A T
E
*NOTE :
If FUTURE TENANT Requires any other
Code Occupancy, Plan must be Resubmitted.
* NOTE :
Gate and Fencing
Details Undetermined
Revisions By
Drawn
Checked
Date
Scale
Randy OʹConnor
Owner :
Architect :
Nick Gilman
945012th St ʹEʹ
Paso Robles
805.238.3432
Ron Westbrook
W E
S T
C O
B U
IL
D
E R
S I
N C
03.20.2017
PROJECT 3551 COMBINE STREET
PASO ROBLES, CALIFORNIA
OWNER WESTCO BUILDERS INC.
% RON WESTBROOK
(805) 801-4443
APN 025-437-024, 025
ARCHITECT NICK GILMAN
945012th St
PASO ROBLES
238.3432
PARCEL 16,936 SF
BUILDING AREA 4,912. SF
OFFICE +/- 512 SF
SHOP / STORAGE +/- 4,480 SF
BUILDING TYPE
CODE OCCUPANCY S1 or F1
V-B UnSprinkled
PARKING PROVIDED:
SPECULATIVE BUILDING FOR WESTCO BUILDERS
SCALE 1ʺ = 8ʹ-0ʺ
NORTH 16
VICINITY MAP
#3 Cont.
Top & Bot.
1/2ʺ R, Typ.
5" 1"
6"
21 2"
6"
Class II
Base
A.C.
1 Typ. ʹAʹ Curb
#3 Cont.
1/2ʺ R, Typ.
5" 1"
6"
9" M a x.
#4 Cont.
6" 1'
-0
1'-0" #4 Cont.
#3 Verts
@ 16ʺ o.c.
8"
ʺ
M a x
1'-0"
1/2ʺ R, Typ.
#4 Cont.
V a ri es
Class II Base
21 2" 6"
A.C.
1' -0
TS1 SITE PLAN
G GRADING
A1 FLOOR PLAN
A2 FOUNDATION
A3 ELEVATIONS
A4 SECTIONS
A5 ELECTRICAL /
HVAC / PLUMBING
A6 ADA REQUIREMENTS
SHEET INDEX
2016 Edition of the California
Code of Regulations Title 24
2016 California Building Code
2016 California Electric Code
2016 California Mechanical Code
2016 California Plumbing Code
2016 California Fire Code
2016 California Energy Code
Green Building Standards Code
THIS PROJECT SHALL
COMPLY WITH:
Exhibit A- Building Drawings
Revisions By
Drawn
Checked
Date
Scale
Randy OʹConnor
Owner :
Architect :
Nick Gilman
945012th St ʹEʹ
Paso Robles
805.238.3432
Ron Westbrook
W E
S T
C O
B U
IL
D
E R
S I
N C
03.20.2017
'-0
26'-0" 40'-0"
'-0
ʹ x
4ʹ
R o ll -u p D o o r
14ʹ x 14ʹ Roll-up Door
14ʹ x 14ʹ Roll-up Door
6030 /
6060 Stack
6030 /
6060 Stack
36703670
33'-0" 33'-0"
2'-0"
14'-0" 2'-0" 3'-0" 18'-0" 14'-0" 2'-0" 3'-0" 8'-0"
ʹXʹ Bracing
ʹXʹ Bracing
WOOD ADD-ON
17'-4"
8' -0
'-0
7'-0"9'-0"
83'-4"
'-4
8'
-8
18'-0"
84'-0"
7' -0
'-0
7'
-0
'-4
8'-6"
39'-4"
Electric Meter, Main & Dist.
6' -4
7'
-4
'-8
5/8ʺ th. Gyp. Bd each Face
ʺ
T
JI
ʺ o .c
2x4 @ 16ʺ o.c.
2x4 @ 16ʺ o.c.
2x
6ʺ o
.c
B 4ʹ -8 ʺ
A 4.0ʹ
A 4.0ʹ
A 6.0ʹ
A8ʹ -6 ʺ
1 3/4ʺx 16ʺ LVL Header
B
3ʹ-0ʺ
2 2
6"
8' -0
'-0
4' -0
2ʺ Clear @
Wood to Steel
Occupant Load - 7
SHOP / STORAGE
OFFICE
Maximum Occupant Load - 42
Lockable
Bicycle Rack
FLOORPLAN
SCALE 1/4ʺ = 1ʹ-0ʺ NORTH
Checked
Date
Scale
Randy OʹConnor
Owner :
Architect :
Nick Gilman
945012th St ʹEʹ
Paso Robles
805.238.3432
Ron Westbrook
W E
S T
C O
B U
IL
D
E R
S I
N C
03.20.2017
(4) - 5/8ʺØ w/ 5ʺ Embedment
'-6
'-0
'-6
'-0
2' -6
"1' -0
1'-0"
1'-0"
1' -8
1' -0
'-0
'-0
7' -0
'-0
ʺ w id e x
ʺ
E m b ed m en t w
(3
#5
T o p
B o tt o m
84'-0"
(4
1ʺ
Ø w
7ʺ E m b ed m en t
6'-0"
2' -6
"1' -0
2'-2"
1'-6"
1'-6"
2'-6"
2' -6
1' -0
1'-0"
1' -0
1'-0"
2' -6
6' -0
7' -0
'-4
'-4
25'-0" 17'-10" 15'-0" 25'-6"
(4) - 5/8ʺØ w/ 5ʺ Embedment
(4) - 5/8ʺØ w/ 5ʺ Embedment
18ʺ wide x 30ʺ Embedment w/ (2) - #5 Top & Bottom
(4) - 5/8ʺØ w/ 5ʺ Embedment F
F
F
F
12ʺ wide x 24ʺ Embedment w/ (1) - #5 Top & Bottom
18ʺ wide x 30ʺ Embedment w/ (2) - #5 Top & Bottom
17'-4" 26'-0" 33'-0" 7'-0"
8' -8
ʺ w id e x
ʺ
E m b ed m en t w
(1
#5
T o p
B o tt o m
(4
5/
8ʺ Ø w
5ʺ E m b ed m en t
H
AC
(4
3/
4ʺ Ø w
7ʺ E m b e d m en t
(4
3 /
4ʺ Ø w
7 ʺ E m b ed m en t
ʺ w id e x
ʺ
E m b ed m en t w
(4
#5
T o p
B o tt o m
ʺ w id e x
ʺ
E m b ed m en t w
(1
#5
T o p
B o tt o m
ʺ w id e x
ʺ
E m b ed m en t w
(4
#5
T o p
B o tt o m
(4
3/
4ʺ Ø w
7ʺ E m b ed m en t
JE
(4
3/
4ʺ Ø w
7ʺ E m b ed m en t
(4) - 5/8ʺØ w/ 5ʺ Embedment
(4) - 5/8ʺØ w/ 5ʺ Embedment
(4
5/
8ʺ Ø w
5ʺ E m b ed m en t
(4) - 5/8ʺØ w/ 5ʺ Embedment (4
1ʺ Ø w
7ʺ E m b ed m en t
ʺ w id e x
ʺ
E m b ed m en t w
(4
#5
T o p
B o tt o m
ʺ w id e x
ʺ
E m b ed m en t w
(4
#5
T o p
B o tt o m
K
K
F
F D B
(4
3/
4ʺ Ø w
7ʺ E m b ed m en t
B
(4
3/
4ʺ Ø w
7ʺ E m b ed m en t
ʺ w id e x
ʺ
E m b ed m en t w
(1
#5
T o p
B o tt o m
83'-4"
B 4ʹ -8 ʺ
A 4.0ʹ
A 4.0ʹ
A 6.0ʹ
A8ʹ -6 ʺ
1'-0"
1' -0
12ʺ wide x 12ʺ Embedment w/ (1) - #5 Top & Bottom
(for Future Office)
2' -6
ʺ w id e x
ʺ
E m b ed m en t w
(1
#5
T o p
B o tt o m
8"
1'-6"
1'-6"
2'-2"
2'-2"
1 23 2
4 2
3 2
2a
3 23 2
1 21 2
19'-6"15'-0"19'-6"24'-0"
6ʺ Concrete Slab w/
#4 @ 24ʺ o.c. each way on 4ʺ sand or DG Base
* Note:
All Bolts Epoxy Set
@ A B C D E I K per Simpson Set, or Eq.
B
3ʹ-0ʺ
2 2
D
GGGG
8"
G G
A
@ G and H
5/8ʺ Ø Bolts may be cast in place
10ʺ long A.B. or Epoxy Set w/ 3-3/4ʺ Embedment.
- See ʹStarʹ Drawings F1 & F2 for Precise Bolt Location.
- Sawcut Slab 3/4ʺ min. @ max 30ʹx30ʹ within 12 hours of Finish.
G G
8' -2
FOUNDATION PLAN
SCALE 1/4ʺ = 1ʹ-0ʺ NORTH
SYMBOL HOLD DOWN ANCHORAGE
HOLDOWN SYMBOLS (simpson or equal)
SHEARWALL SCHEDULE
A 7/16ʺ DF Struct 1
CDX - APA 24/0
8d @
6ʺ/12ʺ o.c.
SYMBOL PANEL NAILING
TOP PLATE
CONNECTOR
# Fdn. A.B.ʹs per Panel
A35 @ 24ʺo.c. 280# /Ft.
B 8d @
4ʺ/12ʺ o.c.
A35 @ 16ʺo.c.7/16ʺ DF Struct 1
CDX - APA 24/0
5/8ʺØ @ 24ʺ o.c.
Min. 3x Sill Plate
5/8ʺØ @ 32ʺ o.c.
ALLOW
430# /Ft.
w/ (18) - 16d to 4x Stud
& SSTB20 - 5/8ʺØ A.BoltHTT4
ALLOWABLE
*Simpson w/ (24) - 1/4ʺx 2-1/2ʺSDS to 4x
& 7/8ʺØ SB7/8x24ʺ - A.BoltHDC 10/4
*Simpson
3ʺ
2ʹ -0 ʺ
4ʺ 6ʺ
#5 Cont.
Top & Bot.
#5 Cont.
Top & Bot.
1ʹ-0ʺ
#4@ 24ʺ o.c.
ea. way @ Slab
#4 Verts
@ 48ʺ o.c.
3ʺ
2ʹ -0 ʺ
4ʺ 6ʺ
(2) - #5 Cont.
Top & Bot.
(2) - #5 Cont.
Top & Bot.
#3 Stirrup
@ 30ʺ o.c.
#4@ 24ʺ o.c.
ea. way @ Slab
1ʹ-6ʺ
2a
3ʺ
4ʺ 6ʺ
(4) - #5 Top
& Bottom
(4) - #5 Top
& Bottom
2ʹ -6 ʺ
#3 Stirrup
@ 30ʺ o.c.
#4@ 24ʺ o.c.
ea. way @ Slab
2ʹ-6ʺ
3ʺ
4ʺ 6ʺ
#5 Cont. T. & B.
1ʹ-0ʺ
#4@ 24ʺ o.c.
ea. way @ Slab
2x4 Studs @ 16ʺ 0.c. w/
5/8ʺ Gyp. Board ea side.2x4 PT DF Sill w/
0.145ʺØ pins @ 32ʺ o.c.
( Simpson #PDP300 or Eq.)
CONCRETE -
MATERIALS :
Transit Mix P.C. Concrete w/
Min. 2500 psi - 28 day Design.
REINFORCING STEEL -
#3 & 4 Bars Conforming to astm #A-615-40
#5 Bars Conforming to astm #A-615-60
ANCHORS -
In PT Wood to be Approved Hot Dipped
Zinc Coated Galvanized Steel.
Checked
Date
Scale
Randy OʹConnor
Owner :
Architect :
Nick Gilman
945012th St ʹEʹ
Paso Robles
805.238.3432
Ron Westbrook
W E
S T
C O
B U
IL
D
E R
S I
N C
03.20.2017
9' -6
4'
-6
4'-0" 6'-0" 6'-0" 6'-0" 4'-0"
6030 A
6060 B
6030 A
6060 B
E Safety
Glass
7'-6"9'-0"
9' -0
E
Safety
Glass
Safety
Glass
6x6 Header 6x6 Header
6x8 Header6x8 Header
Gutter
'-6
3ʺx4ʺ
Downspout
3ʺx4ʺ
Downspout
3ʺx4ʺ
Downspout
12ʹ x 14ʹ
CRANK OPERATED
SERVICE DOOR -
COOKSON TYPE ʹFKʹ
OR APPROVED EQ.
12ʹ x 14ʹ
CRANK OPERATED
SERVICE DOOR -
COOKSON TYPE ʹFKʹ
OR APPROVED EQ.
1 1
Roof Beyond
12ʹ-0ʺ x 3ʹ-0ʺ 12ʹ-0ʺ x 3ʹ-0ʺ
'-0
8'-0"
'-0
6'
-6
7'-0" 26'-0" 9'-0" 12'-0" 3'-0"
1/2
'-6
'-6
12ʹ x 14ʹ
CRANK OPERATED
SERVICE DOOR -
COOKSON TYPE ʹFKʹ
OR APPROVED EQ.
D D
6'-0"
9' -6
4'
-6
Safety
Glass
C
6x4 Header
2x8
2x6 Block each side -
CS18 Strap over All.
F
SOUTH ELEVATION
SCALE 1/4ʺ = 1ʹ-0ʺ
NORTH ELEVATION
SCALE 1/4ʺ = 1ʹ-0ʺ
EAST ELEVATION
SCALE 1/4ʺ = 1ʹ-0ʺ
DUAL GLAZED +/- 1 3/4ʺ x 4 1/2ʺ ALUMINUM FRAMED ;
- KWANEER US ALUMINUM OR APPROVED EQ.
- DOORS ; 3070 w/ HEAD MOUNT, CONCEALED
CLOSER, ADAMSRITE LOCKSET, BUTT HINGES,
#CO9 PULLS EACH SIDE ; INCLUDE THRESHOLDS
AND WEATHERSTRIPPING.
DOOR SCHEDULE
1 3068 1-3/4ʺ th. FOAM CORE 20 Ga. STEEL DOOR w/ 18 Ga. UNIVERSAL STEEL FRAME.
- SCHLAGE #A-70 LOCKSET, ʹJUPITERʹ LEVER, OR EQ.
- 1.1/2 PAIR BUTTS, DOOR LOCKSET ALWAYS FREE
FROM INTERIOR. 6030 XXA
3068 1-3/8ʺ th. SOLID CORE w/ PT Gr. HARDWOOD FACES.
- SCHLAGE #AL-70PD w/ ʹJUPITERʹ LEVER, OR EQ.
- 1.1/2 PAIR BUTTS
GLAZING SCHEDULE
3068 1-3/8ʺ th. SOLID CORE w/ PT Gr. HARDWOOD FACES.
- SCHLAGE #AL-40S w/ ʹJUPITERʹ LEVER, OR EQ.
- 1.1/2 PAIR BUTTS
WINDOWS : Dual Glazed Aluminum Framed, True Divided Lite ; Milguard Series 710 or approved equal.
6060 XXB
3030 XXC
12030 XXXXD
STOREFRONTS :
9090E
3496F
*NOTES :
1). MAXIMUM FORCE TO OPERATE DOORS TO BE 5 LB/ FT.
2). OPERATING HARDWARE TO BE CENTERED BETWEEN 34ʺ TO 44ʺ AFF.
3). BOTTOM 10ʺ OF GLAZED DOORS SHALL BE ALUMINUM KICK PANEL.
SAFETY GLAZE
SAFETY GLAZE
Checked
Date
Scale
Randy OʹConnor
Owner :
Architect :
Nick Gilman
945012th St ʹEʹ
Paso Robles
805.238.3432
Ron Westbrook
W E
S T
C O
B U
IL
D
E R
S I
N C
03.20.2017
Roof Beyond
1/2
MBCI 7.2 Panel - 26 ga.
- or Equal - ʹDesert Sandʹ
MBCI 7.2 Panel - 26 ga.
- or Equal - ʹLight Stoneʹ
6' -6
'-0
WEST ELEVATION
SCALE 1/4ʺ = 1ʹ-0ʺ
SECTION
SCALE 1/8ʺ = 1ʹ-0ʺ
2x4ʹs @ 16ʺ o.c.
3/4ʺ DF Subfloor - cont. Glue
& Nail w/ 10d 2 8ʺ/12ʺ - over
14ʺ TJI 230 @ 16ʺ o.c.
6'-0" 1'-0"
1'-0"
(2) #4ʹs, cont.
R30
Insulation
16ʺ LSL Rim, typ.16ʺ LSL Rim, typ.
R11 Insulation
R19 Insulation
OFFICE SECTION
SCALE 1/4ʺ = 1ʹ-0ʺ
6x8 x 14ʹ Long
5/8ʺ Sheathing (APA 40:20)
- Nail w/ 8d @ 6ʺ/12ʺ o.c.
1' -6
1'
-6
'-8
'-2
2' -0
8'-8"
2x8ʹs @ 24ʺ o.c.
3 1/2ʺx11 7/8ʺ PSL
3 1/2ʺx11 7/8ʺ PSL
7/16ʺ Sheathing
2x6 PT DF w/
5/8ʺØ AB @ 48ʺ o.c.
Typ. Platform
Framing
3/4 ʹ DF Subfloor
Maintain 2ʺ Clear of Metal Roof
4x6 Cripple on top of PSL
2 12 1/2
R19
R19
R30
4x6 Post Above and Below PSL
MSTA49 Strap w/
(10) - 10d Top & Bot.
PLAN
VIEW
3 1/2ʺx11 7/8ʺ PSL
2x6 Stud continuous to wall Top Plate
SECTION
SCALE 1/4ʺ = 1ʹ-0ʺ
B
A
4ʹ -0 ʺ
FRP to 48ʺ
1ʹ-6ʺ
Mirror
M.R. Gyp. Board
Top Set Base, Typ.
M.R. Gyp Board
Top Set Base, Typ.
FRP to 48ʺ FRP to 48ʺ
2ʹ M.R. Gyp Board
M.R. Gyp Board
Top Set Base, Typ.
BATHROOM ELEVATIONS
SCALE 1/4ʺ = 1ʹ-0ʺ
Metal Cap per ʹStarʹ
Metal Liner Panel per ʹStarʹ
Metal Roofing
Flashing
5/8 th. APA 40:20 Sheathing w/ 10d @ 6ʺ/12ʺ 0.c.
1/2
26 Ga.
Corrugated Panel
7/16ʺ DF
Sheathing
2x6 @
16ʺ o.c.
2x8 @ 24ʺ o.c.
LU28 Hangers
2x8 Ledger w/ (2) - 16d each Stud & Block
Tyvek
'-0
2'
-6
55'-8"
1/2
5/8ʺ Sheathing w/
8d@ 6ʺ/12ʺ over
2x8ʹs @ 24ʺ o.c.
1' -6
1'
-6
'-8
2' -0
3 1/2ʺx11 7/8ʺ PSL
#HTT4 HDS w/ 5/8ʺØ
#SSTB16 - 13ʺ Embed
Maintain 2ʺ Clear of Metal Roof
4x6 Cripple on top of PSL
6x8 x 14ʹ Long
8'-2"
Steel
Frame
40ʺx 40ʺ
Clear
40ʺx 114ʺ
Clear
4'-71 2" 3'-4" 61
2" 2ʺ Clear
MSTA49 Straps w/
(10) - 10d Top & Bot.
4x6 Post
#HDC10/4 HD
w/ SB7/8x24
2x8 Rim
6x6 Hdr.
EAST WALL FRAMING
SCALE 1/4ʺ = 1ʹ-0ʺ
5/8ʺ Sheathing w/
8d@ 6ʺ/12ʺ over
2x8ʹs @ 24ʺ o.c.
(2) - 10d per Block
Block @
Rafters
7/16ʺ Sheathing
6x8
BALOON FRAME
ABOVE DECK
5/8ʺ Sheathing w/
8d@ 6ʺ/12ʺ over
2x8ʹs @ 24ʺ o.c.
Continuous
Metal Roof
2x8 @ 24ʺ o.c.
3 1/2ʺx11 7/8ʺ PSL
8ʺ Eave Girt
2"
WOOD ROOF
@ METAL
8ʺ ʹCʹ Jamb
Siding
Corner
Caulk
Trim
1 3/4ʺx 4 1/2ʺ
Alum. Frame
Typ. @
STEEL DOOR
8ʺ ʹCʹ Jamb
Siding Caulk
Trim
1 3/4ʺx 20 Gauge
Steel Door
3 1/2ʺx 1 1/2ʺ
18 Gauge Steel Jamb
6 Typ. @ DOOR /
WINDOW
Steel Colʹs.
& Girts
2"
Vert. Metal
Siding
7/16ʺ Siding w/
Tyvek under Horiz.
Metal Siding 5
WOOD WALL
@ STEEL
Metal Corner Trim w/
Closure Strip @ Horiz.Siding
* NAILING SCHEDULE Shall meet the
Requirements of CBC #T-2304.10.1
Checked
Date
Scale
Randy OʹConnor
Owner :
Architect :
Nick Gilman
945012th St ʹEʹ
Paso Robles
805.238.3432
Ron Westbrook
W E
S T
C O
B U
IL
D
E R
S I
N C
03.20.2017
E L
E C
T R
IC
A
L P
L U
M B
IN
G
H
V A
C
BB
B B
B
AA
A
H B
HB HB
H B
H B
S3
S3
S3
S3 S3
S3
CCCC
C C
C C
C C
D D D
D D D D
D D D
15ʹ AFF
15ʹ AFF
15ʹ AFF
18ʹ AFF
18ʹ AFF
18ʹ AFF18ʹ AFF
18ʹ AFF
S3
S3
G
FE
S
200A 120V/230V 3Ø
METER PANEL w/ 42 Spaces
- 2ʺØ Conduit to exterior
6ʺx6ʺ RC Box
CoTG
CoTG
CoTG
Connect to
Existing Lateral
4ʺ Ø
4ʺ Ø
3ʺØ 3ʺØ Schedule DWV PVC min 1/4ʺ per foot slope
3/4ʺ
Ø CW
1ʺ Ø
S ch ed u le
P
V C
3/4ʺ Water Meter
PGE
2ʺ Ø
S ch ed ule
PVC fo r A
TT
5ʺ Ø
P
C D uct
GROUND MOUNT
HEAT PUMP
A
C
B
C
Irrigation
Valve Box
1ʺ Ø
3/4ʺØ
3/4ʺØ to
Hose Bibs
5ʺØ P&C Duct
5ʺ Ø
P
C D u ct
Fiberglass Service Sink on Integral Support
1ʺØ VTR
2ʺ Ø
1 1/2ʺØ VTR
S S G as
DEMAND
WATER HEATER
@ 6ʹ-8ʺ from Floor
G a s
M et er
1ʺØ Gasto HWH
SCALE 1/4ʺ = 1ʹ-0ʺ
NORTH
200A -120/230V 3Ø 4W - 10,000 AIC
* Extend 1 1/2ʺ Conduit to Roof for Future Solar
E
60 CFM CEILING EXHAUST FAN,
QUIET TYPE, DUCT TO WALL SCUPPER
D
RECESSED LED TROFFER ; 1ʹx4ʹ , 40W
E-CONOLIGHT # E-TR14L24O4U, or EQ.
6ʺ Ø RECESSED 21W LED ;
E-CONOLIGHT # E-A6L21-IT, or EQ.
WALL MOUNT @ 7ʹ-6ʺ AFF DECORATIVE LED
AS SELECTED BY OWNER.
F
G
* WIRING METHODS :
MAY BE ʹROMEXʹ INSIDE PROTECTED WALLS,
OR COPPER IN CONDUIT ELSEWHERE.
DUPLEX OUTLETS MIN. 15ʺ
TO BOTTOM FROM FLOOR ;
MAX. 48ʺ TO TOP.
S CONTROLLS MAX 48ʺ TO TOP
FROM FLOOR
A GROUND MOUNT 24K BTUw/ 18 SEER
HEAT PUMP - FUJITSU #AOU24RLB, OR EQ.
MECHANICAL SYMBOLS
B
9K BTU WALL MOUNT UNIT (8ʹ-6ʺ AFF)
FUJITSU #ASU9RLF1, OR EQ.
C
17K BTU WALL MOUNT UNIT (8ʹ-6ʺ AFF)
FUJITSU #ASU7RLF1, OR EQ.
* SUPPLY LINE SETS, BRANCH BOX,
AND ALL REQUIRED ELEMENTS FOR
A COMPLETE OPERATING SYSTEM.
ELECTRICAL
PLUMBING / HVAC
PLAN
The contractor shall submit a construction & demolition recycling plan & disposal report to the Paso Robles Building
Department prior to issuance of a building permit.
Minimum 50% of the non-hazardous construction or demolition debris shall be recycled and / or salvaged, unless a local construction and demolition waste management ordinance is more stringent.
At the time of final inspection, an ʺoperation and maintenance manualʺ shall be placed in the building, and shall contain the information specified in CGBSC Section 4.410.1
Any installed gas fireplace shall be a direct-vent sealed-combustion type.
CBSC Section 4.503.1
Duct and other related air distribution equipment openings shall be covered with tape, plastic or other acceptable means at the time of rough installation, during storage on site, and until final startup of the HVAC systems.
Moisture content of building materials shall be verified prior to enclosure. Framing members shall not be enclosed when the moisture content exceeds 19%.
Bathroom exhaust fans shall comply with the following:
a. Be Energy Star certified
b. Unless functioning as a part of the whole house ventilating system, fans must be controled by a humidity control capable of adjustment between a relative humidity range of (min) 50% to (max) 80%.
*NOTE :
HVAC System, Lighting Controlls, and
Water Heating shall be tested per CGC #5.410A
5.504.4.2 5.504.4.4
A TOILET : TANK TYPE ELONGATED ; MIN. 17ʺ - 19ʺ SEAT HEIGHT.
MAX 1.28 GAL. FLUSH - KOHLER ʹHIGHLINEʹ or EQUAL..
B LAVATORY : WALL MOUNT @ 34ʺ AFF : 20ʺ x 18ʺ KOHLER ʹCHESAPEAKEʹ or EQUAL.
w/ SINGLE LEVER FAUCET w/ MAX. 0.5 GPM MIN. FLOW ; MOEN or EQUAL.
C DEMAND WATER HEATER : RINNAI #2532-FFU(C) , or EQUAL -w/ MIN. 3/4ʺ Ø GAS SUPPLY & 3/4ʺ Ø CW SUPPLY.
PLUMBING FIXTURES
* NOTE :
MAX HW TEMPERATURE IS 120° F ;
HW THERMOSTAT IS NOT CONSIDERED CONTROL.
PLUMBING MATERIALS
WATER :
- BELOW GRADE ; SCHED 40 PVC
- ABOVE GRADE ; PEX - FLUSH LINE
BEFORE USE PER CPC 604.1.2
*INSULATE ALL HW LINES w/ MIN.
3/8ʺ th CLOSED CELL NEOPRENE
WASTE :
- BELOW GRADE ; SCHED ʹDWVʹ PVC
- ABOVE GRADE ; ʺ NO HUIS ʺ CAST IRON
VENTS : ABS w/ GALV. FLSHINGS
GAS : SCHED 40 BLACK STEEL
HOSE BIBS : BRONZE CAST, KEYLESS w/ GALV. NIPPLE
& w/ BACKFLOW PREVENTION.
Checked
Date
Scale
Randy OʹConnor
Owner :
Architect :
Nick Gilman
945012th St ʹEʹ
Paso Robles
805.238.3432
Ron Westbrook
W E
S T
C O
B U
IL
D
E R
S I
N C
03.20.2017
A D
A D
E T
A
IL
S
APPROPRIATE INFORMATION
MUST BE INCLUDED ON
SIGN (MINIMUM OF 1ʺ
IN HEIGHT)
LETTERING ON
SIGN MUST BE
A MINIMUM OF
1ʺ IN HEIGHT
UNAUTHORIZED VEHICLES
PARKED IN DESIGNATED
ACCESSIBLE SPACES
NOT DISPLAYING
DISTINGUISHING PLACARDS
OR SPECIAL LICENSE PLATES
ISSUED FOR PERSONS
WITH DISABILITIES
WILL BE TOWED AWAY AT
THE OWNERʹS EXPENSE.
TOWED VEHICLES MAY BE
RECLAIMED AT
OR BY TELEPHONING
1148 PASO ROBLES ST
226 9099
17" MIN.
M
IN
M
A X
M
A X
SANITARY
NAPKIN
DISPENSER
TOILET SEAT
COVER
DISPENSER
PAPER TOWEL
DISPENSER
DRYER
HAND
ELECTRIC MIRROR
2'X3'
LAVATORY/
SOAP DISPENSER
HIGHEST
OPERATING PART,
TYP.
S
T D
A
C C
E S
S
IB
L E
F
L U S
H H
A N
D L
E
" M
IN
" M
IN
" M A
X
" M A
X
INSULATED
TRAP, SMD.
24" MIN.
36" MAX.
T.O. SEAT
6"MAX.
12"MIN.
3'-0"
12"MAX.
54" MIN.
42" MIN.
1'-6"
"M A
X
O P
E R
A T
IN
G
C O
N T
R O
L S
LAVS: INSULATE WATER LINES AND DRAINS, PROVIDE 30"x48"
CLEAR FLOOR SPACE FOR FORWARD APPROACH - MAY
INCLUDE KNEE AND TOE SPACE.
FIRE EXT. IN
CABINET
PAPER
SEAT
DISPENSER
TOILET
PAPER
HOLDER
GRAB BARSOAP
DISPENSER
*URINAL
* URINAL SHALL HAVE ELONGATED RIM PROVIDING A
MINIMUM OF 13 1/2" FROM WALL.
COAT
HOOK
6" MIN.
TOE CLEAR
8" MIN.
KNEE CLEAR
6" MIN.
TOE CLEAR
ADA MOUNTING HEIGHTS
36"
PARKING
SPACE EMBLEM
(SEE BELOW)
1/2 RADIUS
BLUE
WHITE
REFLECTORIZED SIGN
CONSTUCTED OF
PORCELIAN STEEL
WITH BEADED TEXT
OR EQUAL
AREA OF SIGN TO BE
A MIN. CF 70 SQ. IN.
80ʺ MIN. TO TOP OF
WALKING SURFACE FOR
FREE STANDING SIGN -
60ʺ ON WALL OR FENCE
VAN ACCESSABLE
80ʺ MIN.
car
A. 18' minnimum length each parking space CBC 11B-502
B. 9' minnimum width each parking space CBC 11B-502
C. Minimum 18'x5' access aisle (passenger side) CBC 11B-502
D. Surface of the parking space(s) and access aisle(s) does not exceed 1:48 gradient (2%) in any direction CBC 11B-502.4
4' -0
8'-0"9'-0"
'-0
"NO PARKING"
WHITE - 12" HIGH LETTERS
min.min.
" VAN ACCESSIBLE "
PARKING SIGN
INTERNATONAL SYMBOL
OF ACCESSIBILITY
STALL EMBLEM
ACCESSIBLE ISLE
1) Disabled parking space must permit use of either car doors.
2) A parking bumper is required when no curb or barrier is provided which will prevent encroachment of cars over the adjoining accessible route.
3) Wheelchair users must not be forced to go behind parked cars other than their own to access an adjoining accessible route.
4) The maximum surface slope within the disabled parking space and adjacent access aisle may not exceed 2% in any direction.
5) Curb ramps may not encroach into the required dimensions of disabled parking space and adjacent access aisles.
6) Access aisle (loading / unloading area) must connect to an accessible path of travel to the facility.
GENERAL DISABLED PARKING SPACE NOTES :
ADA DOOR SIGNAGE
RESTROOM1. POLE OR WALL MOUNTED REFLECTORIZED SIGN, MIN 70” SQ INCHES AREA,
80 INCHES FROM BOTTOM OF SIGN TO PARKING SPACES FINISH GRADE,
DISPLAYING PROFILE VIEW OF WHEEL CHAIR WITH OCCUPANT IN WHITE OR
DARK BLUE BACKGROUND AND STATING VAN ACCESSIBLE, MIN. FINE $250.
2. POLE MOUNT 17” X 22” WITH 1” MIN LETTERING STATING:
“UNAUTHORIZED VEHICLES PARKING IN DESIGNATED ACCESSIBLE SPACES NOT
DISPLAYING DISTINGUISHED PLACARD OR LICENSE PLATES ISSUED FOR PERSONS
WITH DISABILITIES WILL BE TOWED AWAY AT OWNER EXPENSE. TOWED VEHICLES
MAY BE RECLAIMED AT OR BY TELEPHONING
(BLANK SPACES ARE TO BE FILLED IN WITH APPROPRIATE INFORMATION)
3. 36” X 36” SURFACE I.D. PROFILE VIEW OF A WHEEL CHAIR WITH OCCUPANT IN
WHITE ON BLUE BACKGROUND. LOCATED TO BE VISIBLE TO A TRAFFIC
ENFORCEMENT OFFICER WHEN A VEHICLE IS PARKED.
4. STRIPES AT 36” O.C. WITH WORDS “NO PARKINGʺ (12ʺ HIGH)
- 8’ WIDE VAN ACCESSIBLE.
5. CROSS SLOPE AT PAVING NOT TO EXCEED ¼” FT. PROVIDE 5’ X 5’ LEVEL LANDING
AT ENTRANCES AND EXIT WITH ¼” MAX OFFSET AT THRESHOLD.
6. POLE MOUNT TRAFFIC SIGN STATING “DO NOT ENTER-ONE WAY”
* VERIFY COMPLIANCES OF EXISTING H.C.
SIGNAGE AND SITE ACCESSIBILITY
*SITE H.C. SIGNAGE & NOTES
WALKS & SIDEWALKS
1. WALKS AND SIDEWALKS SHALL HAVE A CONTINUOUS COMMON SURFACE, NOT
INTERRUPTED BY STEPS OR BY ABRUPT CHANGES IN LEVEL EXCEEDING ½” AND
SHALL BE A MINIMUM OF 48” IN WIDTH. CBC #11B-303.
2. ABRUPT CHANGES IN LEVEL ALONG ANY ACCESSIBLE ROUTE EXCEEDING ½” SHALL
COMPLY WITH THE REQUIREMENTS FOR CURB RAMPS. CBC #11B-303.3
3. WHEN ABRUPT CHANGES IN LEVEL NOT EXCEEDING ½” OCCUR, THEY SHALL BE
BEVELED WITH A SLOPE NO GREATER THAN 1:2, EXCEPT THAT LEVEL CHANGES NOT
EXCEEDING ¼” MAY BE VERTICAL. CBC #11B-303.3.
4. WHEN THE SLOPE IN THE DIREVTION OF TRAVEL OF ANY WALK EXCEEDS 1 VERTICAL
TO 20 HORIZONTAL IT SHALL COMPLY WITH THE PROVISIONS OF CBC #11B-405. AS A
PEDESTRIAN RAMP.
5. WALK AND SIDEWALK SURFACE CROSS SLOPES SHALL NOT EXCEED ¼” PER FOOT.
6. WALKS, SIDEWALKS AND PEDESTRIAN WAYS SHALL BE FREE OF GRATING WHENEVER
POSSIBLE. FOR GRATING LOCATED IN THE SURFACE O ANY OF THESE AREAS, GRID
OPENINGS IN GRATING SHALL BE NO GREATER THEN ½” WIDE IN ONE DIRECTION. IF
GRATINGS HAVE ELONGATED OPENINGS, THEY SHALL BE PLACED SO THAT THE LONG
DIMENSION IS PERPENDICULAR TO THE DOMINANT DIRECTION OF TRAVEL. CBC
#11B-302.3.
7. WALKS SHALL BE PROVIDED WITH A LEVEL AREA NOT LESS THAN 60” BY 60” AT A
DOOR OR GATE THAT SWINGS TOWARD THE WALK AND NOT LESS THAN 48” WIDE BY
44” DEEP AT A DOOR OR GATE THAT SWINGS AWAY FROM THAT WALK. CBC #11B-404.
8. WALKS SHALL EXTEND A MINIMUM OF 24” TO THE SIDE OF THE STRIKE EDGE OF A
DOOR OR GATE THAT SWINGS TOWARD THE WALK. CBC #11B-404.2.4.1.
9. WALK AND SIDEWALK SURFACES SHALL BE SLIP-RESISTANT AS FOLLOWS:
CBC #11B-302.
PARKING
1. SURFACE SLOPES OF ACCESSIBLE PARKING SPACES SHALL BE THE MINIMUM
POSSIBLE AND SHALL NOT EXCEED 1 UNIT VERTICAL TO 50UNITS
HORIZONTAL IN ANY DIRECTION. CBC 11B 403.3.
2. THE WORDS “NO PARKING” SHALL BE PAINTED ON THE GROUND WITHIN
EACH LOADING AND UNLOADING ACCESS AISLE PER CBC 11B 502.3.3.
3. VAN ACCESSIBLE PARKING SPACES SHALL HAVE AN ADDITIONAL SIGN
STATING “VAN ACCESSIBLE” MOUNTED BELOW THE SYMBOL OF
ACCESSIBILITY AND POSTED AT A MINIMUM HEIGHT OF 80” FROM THE
BOTTOM OF THE SIGN TO THE PARKING SPACE FINISHED GRADE. CBC 11B 502.6
M
A X
MIN. FINE $250
NOTE :
INSTALL ON EXTERIOR WALL ADJACENT
TO ʺ VAN ACCESSIBLE ʺ SIGN.
7ʺ-9ʺ
ʺ
M
IN
M
A X
* BLUE PAINT @ Perimeter & Diagonals ( @ 36" o.c. )
3'-0"
TACTILE EXIT SIGNAGE
A. LETTERS ON SIGNS ARE RAISED 1/32”, SANS SERIF UPPERCASE CHARACTERS
AND ARE ACCOMPANIED BY GRADE 2 BRAILLE. CBC #11-B 703-2
B. RAISED CHARACTERS ARE BETWEEN 5/8” AND 2” HIGH. CBC #11-B 703-2.
C. BRAILLE DOTS ARE 1/10” ON CENTER IN EACH CELL WITH 2/10” SPACE BETWEEN
CELLS, MEASURED FROM THE SECOND COLUMN OF DOTS IN THE FIRST CELL
TO THE FIRST COLUMN OF DOTS IN THE SECOND CELL. CBC #11-B 703-3
D. BRAILLE DOTS ARE RAISED A MINIMUM OF 1/40” ABOVE THE BACKGROUND.
CBC #11-B 703-3.
E. CHARACTERS AND BACKGROUND OF SIGNS IS EGGSHELL, MATTE, OR OTHER
NON-GLARE FINISH. CBC #11-B 703-5
F. CHARACTERS CONTRAST WITH THEIR BACKGROUND (LIGHT CHARACTERS ON A
DARK BACKGROUND, OR DARK CHARACTERS ON A LIGHT BACKGROUND).
CBC #11-B 703-5.
G. SIGNS ARE INSTALLED ON THE WALL ADJACENT TO THE LATCH SIDE OF THE
DOOR (AT DOUBLE LEAF DOORS AND WHEN THERE IS NO WALL SPACE AT THE
LATCH SIDE, SIGNS SHALL BE PLACED ON THE NEAREST ADJACENT WALL,
PREFERABLE TO THE RIGHT). CBC #11-B 703.4.2.
H. MOUNTING HEIGHT IS 48" MIN. TO 60” MAX. FROM THE FINISH FLOOR TO THE
BASELINE OF THE SIGN. CBC #11-B 703.4.1.
Clear
To Edge of Water Closet
ADA TOILET REQUIREMENTS
Grabbar
1'
-6
3'-6"1'-0"
4'-0"
30ʺ x 48ʺ
Clear
2'-0"
12"m ax
5'-0"
5' -0
C le ar
T o
E d g e o f
S in k
NOTE : GRAB BAR REQUIREMENTS
The diameter or width of the gripping surfaces of a Grab bar shall be 1-1/4" to 1-1/2" , or the shape shall provide an equivalent gripping surface. If Grab bars are mounted on an adjacent wall, the space between the wall and the Grab bars shall be 1-1/2".
File details come from the government source that posted it. Updated .