21 Amendment 0006a As-Built Drawings.pdf

PDF 2 MB Posted

Attached to
Design Renovation, System Support Center (SSC), 3551 Combine St., Paso Robles, CA
Solicitation number
697DCK-27-R-00022A
Issued by

About this file

This document is a set of building drawings and specifications for a speculative commercial building project located at 3351 Combine Street, Paso Robles, California. The project, developed by Westco Builders Inc., comprises a 4,912 square foot structure with approximately 512 square feet of office space and 4,480 square feet of shop/storage area on a 16,936 square foot parcel. The building is classified as Code Occupancy S1 or F1 (non-sprinkled, V-B construction) with a maximum occupant load of 42 persons.

The architectural drawings include site plans, floor plans, foundation details, elevations, sections, and mechanical/electrical/plumbing layouts. Structural specifications call for 6-inch concrete slab with #4 rebar on 24-inch centers, various foundation embedments with anchoring systems, wood and steel framing components, and standard commercial roofing. The design incorporates three 14-foot by 14-foot roll-up doors for the shop area, office spaces with standard commercial finishes, accessible parking and facilities compliant with ADA requirements, and mechanical systems including a 24K BTU ground-mounted heat pump with supplemental wall-mounted units. Electrical service includes a 200-amp, 120/230-volt, three-phase panel with 10,000 AIC capacity. All work must comply with the 2016 California Building Code, California Fire Code, California Energy Code, and Green Building Standards Code. The project was designed by architect Nick Gilman and dated March 20, 2017.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

6' -8

16'-0"

6.

0'

6.

0'

146.0'

BUILDING AREA 4,912 SF

Parkway Landscaping

'-0

6'

-0

26'-0"

17'-8" 83'-4" 45'-0"

'-4

8'

-8

4'-0"

'-6

'-6

2 Similar

4ʺ th Concrete w/

#3 @ 24ʺ o.c. ea.way

OFFICE

6ʺ th Concrete w/

#4 @ 24ʺ o.c. ea.way

6ʺ t h C o n cr et e w

#4

4ʺ o .c

. e a

.w a y

5' -6

27'-0" 18'-0"

* NOTE :

See also GRADING PLAN Sheet 2

2-1/2ʺ AC on 6ʺ Class II (or Eq.) Base

SHOP / STORAGE

OCCUPANCY F1, F2, S1, S2

9' -0

9'

-0

'-0

4'

-6

8' -0

Asphalt

5ʺ Down = 1.3%6' -8

4ʺ D o w n

.2

ADA PATH OF TRAVEL

'-0

15'-0"4'-6"

Level Area

Blue Paint @

Perimeter & Diagonals

12ʺ White Letters

(1 2ʺ

W h it e

L et te rs

18ʹ ROLLING GATE

8ʹ F

E N

C E

TRASH ENCLOSURE

6ʹ High Chain Link w/ Slats

8ʹ FENCE

8ʹ FENCE

8ʹ F

E N

C E

ʹ G

A T

E

*NOTE :

If FUTURE TENANT Requires any other

Code Occupancy, Plan must be Resubmitted.

* NOTE :

Gate and Fencing

Details Undetermined

Revisions By

Drawn

Checked

Date

Scale

Randy OʹConnor

Owner :

Architect :

Nick Gilman

945012th St ʹEʹ

Paso Robles

805.238.3432

Ron Westbrook

W E

S T

C O

B U

IL

D

E R

S I

N C

03.20.2017

PROJECT 3551 COMBINE STREET

PASO ROBLES, CALIFORNIA

OWNER WESTCO BUILDERS INC.

% RON WESTBROOK

(805) 801-4443

APN 025-437-024, 025

ARCHITECT NICK GILMAN

945012th St

PASO ROBLES

238.3432

PARCEL 16,936 SF

BUILDING AREA 4,912. SF

OFFICE +/- 512 SF

SHOP / STORAGE +/- 4,480 SF

BUILDING TYPE

CODE OCCUPANCY S1 or F1

V-B UnSprinkled

PARKING PROVIDED:

SPECULATIVE BUILDING FOR WESTCO BUILDERS

SCALE 1ʺ = 8ʹ-0ʺ

NORTH 16

VICINITY MAP

#3 Cont.

Top & Bot.

1/2ʺ R, Typ.

5" 1"

6"

21 2"

6"

Class II

Base

A.C.

1 Typ. ʹAʹ Curb

#3 Cont.

1/2ʺ R, Typ.

5" 1"

6"

9" M a x.

#4 Cont.

6" 1'

-0

1'-0" #4 Cont.

#3 Verts

@ 16ʺ o.c.

8"

ʺ

M a x

1'-0"

1/2ʺ R, Typ.

#4 Cont.

V a ri es

Class II Base

21 2" 6"

A.C.

1' -0

TS1 SITE PLAN

G GRADING

A1 FLOOR PLAN

A2 FOUNDATION

A3 ELEVATIONS

A4 SECTIONS

A5 ELECTRICAL /

HVAC / PLUMBING

A6 ADA REQUIREMENTS

SHEET INDEX

2016 Edition of the California

Code of Regulations Title 24

2016 California Building Code

2016 California Electric Code

2016 California Mechanical Code

2016 California Plumbing Code

2016 California Fire Code

2016 California Energy Code

Green Building Standards Code

THIS PROJECT SHALL

COMPLY WITH:

Exhibit A- Building Drawings

Revisions By

Drawn

Checked

Date

Scale

Randy OʹConnor

Owner :

Architect :

Nick Gilman

945012th St ʹEʹ

Paso Robles

805.238.3432

Ron Westbrook

W E

S T

C O

B U

IL

D

E R

S I

N C

03.20.2017

'-0

26'-0" 40'-0"

'-0

ʹ x

4ʹ

R o ll -u p D o o r

14ʹ x 14ʹ Roll-up Door

14ʹ x 14ʹ Roll-up Door

6030 /

6060 Stack

6030 /

6060 Stack

36703670

33'-0" 33'-0"

2'-0"

14'-0" 2'-0" 3'-0" 18'-0" 14'-0" 2'-0" 3'-0" 8'-0"

ʹXʹ Bracing

ʹXʹ Bracing

WOOD ADD-ON

17'-4"

8' -0

'-0

7'-0"9'-0"

83'-4"

'-4

8'

-8

18'-0"

84'-0"

7' -0

'-0

7'

-0

'-4

8'-6"

39'-4"

Electric Meter, Main & Dist.

6' -4

7'

-4

'-8

5/8ʺ th. Gyp. Bd each Face

ʺ

T

JI

ʺ o .c

2x4 @ 16ʺ o.c.

2x4 @ 16ʺ o.c.

2x

6ʺ o

.c

B 4ʹ -8 ʺ

A 4.0ʹ

A 4.0ʹ

A 6.0ʹ

A8ʹ -6 ʺ

1 3/4ʺx 16ʺ LVL Header

B

3ʹ-0ʺ

2 2

6"

8' -0

'-0

4' -0

2ʺ Clear @

Wood to Steel

Occupant Load - 7

SHOP / STORAGE

OFFICE

Maximum Occupant Load - 42

Lockable

Bicycle Rack

FLOORPLAN

SCALE 1/4ʺ = 1ʹ-0ʺ NORTH

Checked

Date

Scale

Randy OʹConnor

Owner :

Architect :

Nick Gilman

945012th St ʹEʹ

Paso Robles

805.238.3432

Ron Westbrook

W E

S T

C O

B U

IL

D

E R

S I

N C

03.20.2017

(4) - 5/8ʺØ w/ 5ʺ Embedment

'-6

'-0

'-6

'-0

2' -6

"1' -0

1'-0"

1'-0"

1' -8

1' -0

'-0

'-0

7' -0

'-0

ʺ w id e x

ʺ

E m b ed m en t w

(3

#5

T o p

B o tt o m

84'-0"

(4

1ʺ

Ø w

7ʺ E m b ed m en t

6'-0"

2' -6

"1' -0

2'-2"

1'-6"

1'-6"

2'-6"

2' -6

1' -0

1'-0"

1' -0

1'-0"

2' -6

6' -0

7' -0

'-4

'-4

25'-0" 17'-10" 15'-0" 25'-6"

(4) - 5/8ʺØ w/ 5ʺ Embedment

(4) - 5/8ʺØ w/ 5ʺ Embedment

18ʺ wide x 30ʺ Embedment w/ (2) - #5 Top & Bottom

(4) - 5/8ʺØ w/ 5ʺ Embedment F

F

F

F

12ʺ wide x 24ʺ Embedment w/ (1) - #5 Top & Bottom

18ʺ wide x 30ʺ Embedment w/ (2) - #5 Top & Bottom

17'-4" 26'-0" 33'-0" 7'-0"

8' -8

ʺ w id e x

ʺ

E m b ed m en t w

(1

#5

T o p

B o tt o m

(4

5/

8ʺ Ø w

5ʺ E m b ed m en t

H

AC

(4

3/

4ʺ Ø w

7ʺ E m b e d m en t

(4

3 /

4ʺ Ø w

7 ʺ E m b ed m en t

ʺ w id e x

ʺ

E m b ed m en t w

(4

#5

T o p

B o tt o m

ʺ w id e x

ʺ

E m b ed m en t w

(1

#5

T o p

B o tt o m

ʺ w id e x

ʺ

E m b ed m en t w

(4

#5

T o p

B o tt o m

(4

3/

4ʺ Ø w

7ʺ E m b ed m en t

JE

(4

3/

4ʺ Ø w

7ʺ E m b ed m en t

(4) - 5/8ʺØ w/ 5ʺ Embedment

(4) - 5/8ʺØ w/ 5ʺ Embedment

(4

5/

8ʺ Ø w

5ʺ E m b ed m en t

(4) - 5/8ʺØ w/ 5ʺ Embedment (4

1ʺ Ø w

7ʺ E m b ed m en t

ʺ w id e x

ʺ

E m b ed m en t w

(4

#5

T o p

B o tt o m

ʺ w id e x

ʺ

E m b ed m en t w

(4

#5

T o p

B o tt o m

K

K

F

F D B

(4

3/

4ʺ Ø w

7ʺ E m b ed m en t

B

(4

3/

4ʺ Ø w

7ʺ E m b ed m en t

ʺ w id e x

ʺ

E m b ed m en t w

(1

#5

T o p

B o tt o m

83'-4"

B 4ʹ -8 ʺ

A 4.0ʹ

A 4.0ʹ

A 6.0ʹ

A8ʹ -6 ʺ

1'-0"

1' -0

12ʺ wide x 12ʺ Embedment w/ (1) - #5 Top & Bottom

(for Future Office)

2' -6

ʺ w id e x

ʺ

E m b ed m en t w

(1

#5

T o p

B o tt o m

8"

1'-6"

1'-6"

2'-2"

2'-2"

1 23 2

4 2

3 2

2a

3 23 2

1 21 2

19'-6"15'-0"19'-6"24'-0"

6ʺ Concrete Slab w/

#4 @ 24ʺ o.c. each way on 4ʺ sand or DG Base

* Note:

All Bolts Epoxy Set

@ A B C D E I K per Simpson Set, or Eq.

B

3ʹ-0ʺ

2 2

D

GGGG

8"

G G

A

@ G and H

5/8ʺ Ø Bolts may be cast in place

10ʺ long A.B. or Epoxy Set w/ 3-3/4ʺ Embedment.

- See ʹStarʹ Drawings F1 & F2 for Precise Bolt Location.

- Sawcut Slab 3/4ʺ min. @ max 30ʹx30ʹ within 12 hours of Finish.

G G

8' -2

FOUNDATION PLAN

SCALE 1/4ʺ = 1ʹ-0ʺ NORTH

SYMBOL HOLD DOWN ANCHORAGE

HOLDOWN SYMBOLS (simpson or equal)

SHEARWALL SCHEDULE

A 7/16ʺ DF Struct 1

CDX - APA 24/0

8d @

6ʺ/12ʺ o.c.

SYMBOL PANEL NAILING

TOP PLATE

CONNECTOR

# Fdn. A.B.ʹs per Panel

A35 @ 24ʺo.c. 280# /Ft.

B 8d @

4ʺ/12ʺ o.c.

A35 @ 16ʺo.c.7/16ʺ DF Struct 1

CDX - APA 24/0

5/8ʺØ @ 24ʺ o.c.

Min. 3x Sill Plate

5/8ʺØ @ 32ʺ o.c.

ALLOW

430# /Ft.

w/ (18) - 16d to 4x Stud

& SSTB20 - 5/8ʺØ A.BoltHTT4

ALLOWABLE

*Simpson w/ (24) - 1/4ʺx 2-1/2ʺSDS to 4x

& 7/8ʺØ SB7/8x24ʺ - A.BoltHDC 10/4

*Simpson

3ʺ

2ʹ -0 ʺ

4ʺ 6ʺ

#5 Cont.

Top & Bot.

#5 Cont.

Top & Bot.

1ʹ-0ʺ

#4@ 24ʺ o.c.

ea. way @ Slab

#4 Verts

@ 48ʺ o.c.

3ʺ

2ʹ -0 ʺ

4ʺ 6ʺ

(2) - #5 Cont.

Top & Bot.

(2) - #5 Cont.

Top & Bot.

#3 Stirrup

@ 30ʺ o.c.

#4@ 24ʺ o.c.

ea. way @ Slab

1ʹ-6ʺ

2a

3ʺ

4ʺ 6ʺ

(4) - #5 Top

& Bottom

(4) - #5 Top

& Bottom

2ʹ -6 ʺ

#3 Stirrup

@ 30ʺ o.c.

#4@ 24ʺ o.c.

ea. way @ Slab

2ʹ-6ʺ

3ʺ

4ʺ 6ʺ

#5 Cont. T. & B.

1ʹ-0ʺ

#4@ 24ʺ o.c.

ea. way @ Slab

2x4 Studs @ 16ʺ 0.c. w/

5/8ʺ Gyp. Board ea side.2x4 PT DF Sill w/

0.145ʺØ pins @ 32ʺ o.c.

( Simpson #PDP300 or Eq.)

CONCRETE -

MATERIALS :

Transit Mix P.C. Concrete w/

Min. 2500 psi - 28 day Design.

REINFORCING STEEL -

#3 & 4 Bars Conforming to astm #A-615-40

#5 Bars Conforming to astm #A-615-60

ANCHORS -

In PT Wood to be Approved Hot Dipped

Zinc Coated Galvanized Steel.

Checked

Date

Scale

Randy OʹConnor

Owner :

Architect :

Nick Gilman

945012th St ʹEʹ

Paso Robles

805.238.3432

Ron Westbrook

W E

S T

C O

B U

IL

D

E R

S I

N C

03.20.2017

9' -6

4'

-6

4'-0" 6'-0" 6'-0" 6'-0" 4'-0"

6030 A

6060 B

6030 A

6060 B

E Safety

Glass

7'-6"9'-0"

9' -0

E

Safety

Glass

Safety

Glass

6x6 Header 6x6 Header

6x8 Header6x8 Header

Gutter

'-6

3ʺx4ʺ

Downspout

3ʺx4ʺ

Downspout

3ʺx4ʺ

Downspout

12ʹ x 14ʹ

CRANK OPERATED

SERVICE DOOR -

COOKSON TYPE ʹFKʹ

OR APPROVED EQ.

12ʹ x 14ʹ

CRANK OPERATED

SERVICE DOOR -

COOKSON TYPE ʹFKʹ

OR APPROVED EQ.

1 1

Roof Beyond

12ʹ-0ʺ x 3ʹ-0ʺ 12ʹ-0ʺ x 3ʹ-0ʺ

'-0

8'-0"

'-0

6'

-6

7'-0" 26'-0" 9'-0" 12'-0" 3'-0"

1/2

'-6

'-6

12ʹ x 14ʹ

CRANK OPERATED

SERVICE DOOR -

COOKSON TYPE ʹFKʹ

OR APPROVED EQ.

D D

6'-0"

9' -6

4'

-6

Safety

Glass

C

6x4 Header

2x8

2x6 Block each side -

CS18 Strap over All.

F

SOUTH ELEVATION

SCALE 1/4ʺ = 1ʹ-0ʺ

NORTH ELEVATION

SCALE 1/4ʺ = 1ʹ-0ʺ

EAST ELEVATION

SCALE 1/4ʺ = 1ʹ-0ʺ

DUAL GLAZED +/- 1 3/4ʺ x 4 1/2ʺ ALUMINUM FRAMED ;

- KWANEER US ALUMINUM OR APPROVED EQ.

- DOORS ; 3070 w/ HEAD MOUNT, CONCEALED

CLOSER, ADAMSRITE LOCKSET, BUTT HINGES,

#CO9 PULLS EACH SIDE ; INCLUDE THRESHOLDS

AND WEATHERSTRIPPING.

DOOR SCHEDULE

1 3068 1-3/4ʺ th. FOAM CORE 20 Ga. STEEL DOOR w/ 18 Ga. UNIVERSAL STEEL FRAME.

- SCHLAGE #A-70 LOCKSET, ʹJUPITERʹ LEVER, OR EQ.

- 1.1/2 PAIR BUTTS, DOOR LOCKSET ALWAYS FREE

FROM INTERIOR. 6030 XXA

3068 1-3/8ʺ th. SOLID CORE w/ PT Gr. HARDWOOD FACES.

- SCHLAGE #AL-70PD w/ ʹJUPITERʹ LEVER, OR EQ.

- 1.1/2 PAIR BUTTS

GLAZING SCHEDULE

3068 1-3/8ʺ th. SOLID CORE w/ PT Gr. HARDWOOD FACES.

- SCHLAGE #AL-40S w/ ʹJUPITERʹ LEVER, OR EQ.

- 1.1/2 PAIR BUTTS

WINDOWS : Dual Glazed Aluminum Framed, True Divided Lite ; Milguard Series 710 or approved equal.

6060 XXB

3030 XXC

12030 XXXXD

STOREFRONTS :

9090E

3496F

*NOTES :

1). MAXIMUM FORCE TO OPERATE DOORS TO BE 5 LB/ FT.

2). OPERATING HARDWARE TO BE CENTERED BETWEEN 34ʺ TO 44ʺ AFF.

3). BOTTOM 10ʺ OF GLAZED DOORS SHALL BE ALUMINUM KICK PANEL.

SAFETY GLAZE

SAFETY GLAZE

Checked

Date

Scale

Randy OʹConnor

Owner :

Architect :

Nick Gilman

945012th St ʹEʹ

Paso Robles

805.238.3432

Ron Westbrook

W E

S T

C O

B U

IL

D

E R

S I

N C

03.20.2017

Roof Beyond

1/2

MBCI 7.2 Panel - 26 ga.

- or Equal - ʹDesert Sandʹ

MBCI 7.2 Panel - 26 ga.

- or Equal - ʹLight Stoneʹ

6' -6

'-0

WEST ELEVATION

SCALE 1/4ʺ = 1ʹ-0ʺ

SECTION

SCALE 1/8ʺ = 1ʹ-0ʺ

2x4ʹs @ 16ʺ o.c.

3/4ʺ DF Subfloor - cont. Glue

& Nail w/ 10d 2 8ʺ/12ʺ - over

14ʺ TJI 230 @ 16ʺ o.c.

6'-0" 1'-0"

1'-0"

(2) #4ʹs, cont.

R30

Insulation

16ʺ LSL Rim, typ.16ʺ LSL Rim, typ.

R11 Insulation

R19 Insulation

OFFICE SECTION

SCALE 1/4ʺ = 1ʹ-0ʺ

6x8 x 14ʹ Long

5/8ʺ Sheathing (APA 40:20)

- Nail w/ 8d @ 6ʺ/12ʺ o.c.

1' -6

1'

-6

'-8

'-2

2' -0

8'-8"

2x8ʹs @ 24ʺ o.c.

3 1/2ʺx11 7/8ʺ PSL

3 1/2ʺx11 7/8ʺ PSL

7/16ʺ Sheathing

2x6 PT DF w/

5/8ʺØ AB @ 48ʺ o.c.

Typ. Platform

Framing

3/4 ʹ DF Subfloor

Maintain 2ʺ Clear of Metal Roof

4x6 Cripple on top of PSL

2 12 1/2

R19

R19

R30

4x6 Post Above and Below PSL

MSTA49 Strap w/

(10) - 10d Top & Bot.

PLAN

VIEW

3 1/2ʺx11 7/8ʺ PSL

2x6 Stud continuous to wall Top Plate

SECTION

SCALE 1/4ʺ = 1ʹ-0ʺ

B

A

4ʹ -0 ʺ

FRP to 48ʺ

1ʹ-6ʺ

Mirror

M.R. Gyp. Board

Top Set Base, Typ.

M.R. Gyp Board

Top Set Base, Typ.

FRP to 48ʺ FRP to 48ʺ

2ʹ M.R. Gyp Board

M.R. Gyp Board

Top Set Base, Typ.

BATHROOM ELEVATIONS

SCALE 1/4ʺ = 1ʹ-0ʺ

Metal Cap per ʹStarʹ

Metal Liner Panel per ʹStarʹ

Metal Roofing

Flashing

5/8 th. APA 40:20 Sheathing w/ 10d @ 6ʺ/12ʺ 0.c.

1/2

26 Ga.

Corrugated Panel

7/16ʺ DF

Sheathing

2x6 @

16ʺ o.c.

2x8 @ 24ʺ o.c.

LU28 Hangers

2x8 Ledger w/ (2) - 16d each Stud & Block

Tyvek

'-0

2'

-6

55'-8"

1/2

5/8ʺ Sheathing w/

8d@ 6ʺ/12ʺ over

2x8ʹs @ 24ʺ o.c.

1' -6

1'

-6

'-8

2' -0

3 1/2ʺx11 7/8ʺ PSL

#HTT4 HDS w/ 5/8ʺØ

#SSTB16 - 13ʺ Embed

Maintain 2ʺ Clear of Metal Roof

4x6 Cripple on top of PSL

6x8 x 14ʹ Long

8'-2"

Steel

Frame

40ʺx 40ʺ

Clear

40ʺx 114ʺ

Clear

4'-71 2" 3'-4" 61

2" 2ʺ Clear

MSTA49 Straps w/

(10) - 10d Top & Bot.

4x6 Post

#HDC10/4 HD

w/ SB7/8x24

2x8 Rim

6x6 Hdr.

EAST WALL FRAMING

SCALE 1/4ʺ = 1ʹ-0ʺ

5/8ʺ Sheathing w/

8d@ 6ʺ/12ʺ over

2x8ʹs @ 24ʺ o.c.

(2) - 10d per Block

Block @

Rafters

7/16ʺ Sheathing

6x8

BALOON FRAME

ABOVE DECK

5/8ʺ Sheathing w/

8d@ 6ʺ/12ʺ over

2x8ʹs @ 24ʺ o.c.

Continuous

Metal Roof

2x8 @ 24ʺ o.c.

3 1/2ʺx11 7/8ʺ PSL

8ʺ Eave Girt

2"

WOOD ROOF

@ METAL

8ʺ ʹCʹ Jamb

Siding

Corner

Caulk

Trim

1 3/4ʺx 4 1/2ʺ

Alum. Frame

Typ. @

STEEL DOOR

8ʺ ʹCʹ Jamb

Siding Caulk

Trim

1 3/4ʺx 20 Gauge

Steel Door

3 1/2ʺx 1 1/2ʺ

18 Gauge Steel Jamb

6 Typ. @ DOOR /

WINDOW

Steel Colʹs.

& Girts

2"

Vert. Metal

Siding

7/16ʺ Siding w/

Tyvek under Horiz.

Metal Siding 5

WOOD WALL

@ STEEL

Metal Corner Trim w/

Closure Strip @ Horiz.Siding

* NAILING SCHEDULE Shall meet the

Requirements of CBC #T-2304.10.1

Checked

Date

Scale

Randy OʹConnor

Owner :

Architect :

Nick Gilman

945012th St ʹEʹ

Paso Robles

805.238.3432

Ron Westbrook

W E

S T

C O

B U

IL

D

E R

S I

N C

03.20.2017

E L

E C

T R

IC

A

L P

L U

M B

IN

G

H

V A

C

BB

B B

B

AA

A

H B

HB HB

H B

H B

S3

S3

S3

S3 S3

S3

CCCC

C C

C C

C C

D D D

D D D D

D D D

15ʹ AFF

15ʹ AFF

15ʹ AFF

18ʹ AFF

18ʹ AFF

18ʹ AFF18ʹ AFF

18ʹ AFF

S3

S3

G

FE

S

200A 120V/230V 3Ø

METER PANEL w/ 42 Spaces

- 2ʺØ Conduit to exterior

6ʺx6ʺ RC Box

CoTG

CoTG

CoTG

Connect to

Existing Lateral

4ʺ Ø

4ʺ Ø

3ʺØ 3ʺØ Schedule DWV PVC min 1/4ʺ per foot slope

3/4ʺ

Ø CW

1ʺ Ø

S ch ed u le

P

V C

3/4ʺ Water Meter

PGE

2ʺ Ø

S ch ed ule

PVC fo r A

TT

5ʺ Ø

P

C D uct

GROUND MOUNT

HEAT PUMP

A

C

B

C

Irrigation

Valve Box

1ʺ Ø

3/4ʺØ

3/4ʺØ to

Hose Bibs

5ʺØ P&C Duct

5ʺ Ø

P

C D u ct

Fiberglass Service Sink on Integral Support

1ʺØ VTR

2ʺ Ø

1 1/2ʺØ VTR

S S G as

DEMAND

WATER HEATER

@ 6ʹ-8ʺ from Floor

G a s

M et er

1ʺØ Gasto HWH

SCALE 1/4ʺ = 1ʹ-0ʺ

NORTH

200A -120/230V 3Ø 4W - 10,000 AIC

* Extend 1 1/2ʺ Conduit to Roof for Future Solar

E

60 CFM CEILING EXHAUST FAN,

QUIET TYPE, DUCT TO WALL SCUPPER

D

RECESSED LED TROFFER ; 1ʹx4ʹ , 40W

E-CONOLIGHT # E-TR14L24O4U, or EQ.

6ʺ Ø RECESSED 21W LED ;

E-CONOLIGHT # E-A6L21-IT, or EQ.

WALL MOUNT @ 7ʹ-6ʺ AFF DECORATIVE LED

AS SELECTED BY OWNER.

F

G

* WIRING METHODS :

MAY BE ʹROMEXʹ INSIDE PROTECTED WALLS,

OR COPPER IN CONDUIT ELSEWHERE.

DUPLEX OUTLETS MIN. 15ʺ

TO BOTTOM FROM FLOOR ;

MAX. 48ʺ TO TOP.

S CONTROLLS MAX 48ʺ TO TOP

FROM FLOOR

A GROUND MOUNT 24K BTUw/ 18 SEER

HEAT PUMP - FUJITSU #AOU24RLB, OR EQ.

MECHANICAL SYMBOLS

B

9K BTU WALL MOUNT UNIT (8ʹ-6ʺ AFF)

FUJITSU #ASU9RLF1, OR EQ.

C

17K BTU WALL MOUNT UNIT (8ʹ-6ʺ AFF)

FUJITSU #ASU7RLF1, OR EQ.

* SUPPLY LINE SETS, BRANCH BOX,

AND ALL REQUIRED ELEMENTS FOR

A COMPLETE OPERATING SYSTEM.

ELECTRICAL

PLUMBING / HVAC

PLAN

The contractor shall submit a construction & demolition recycling plan & disposal report to the Paso Robles Building

Department prior to issuance of a building permit.

Minimum 50% of the non-hazardous construction or demolition debris shall be recycled and / or salvaged, unless a local construction and demolition waste management ordinance is more stringent.

At the time of final inspection, an ʺoperation and maintenance manualʺ shall be placed in the building, and shall contain the information specified in CGBSC Section 4.410.1

Any installed gas fireplace shall be a direct-vent sealed-combustion type.

CBSC Section 4.503.1

Duct and other related air distribution equipment openings shall be covered with tape, plastic or other acceptable means at the time of rough installation, during storage on site, and until final startup of the HVAC systems.

Moisture content of building materials shall be verified prior to enclosure. Framing members shall not be enclosed when the moisture content exceeds 19%.

Bathroom exhaust fans shall comply with the following:

a. Be Energy Star certified

b. Unless functioning as a part of the whole house ventilating system, fans must be controled by a humidity control capable of adjustment between a relative humidity range of (min) 50% to (max) 80%.

*NOTE :

HVAC System, Lighting Controlls, and

Water Heating shall be tested per CGC #5.410A

5.504.4.2 5.504.4.4

A TOILET : TANK TYPE ELONGATED ; MIN. 17ʺ - 19ʺ SEAT HEIGHT.

MAX 1.28 GAL. FLUSH - KOHLER ʹHIGHLINEʹ or EQUAL..

B LAVATORY : WALL MOUNT @ 34ʺ AFF : 20ʺ x 18ʺ KOHLER ʹCHESAPEAKEʹ or EQUAL.

w/ SINGLE LEVER FAUCET w/ MAX. 0.5 GPM MIN. FLOW ; MOEN or EQUAL.

C DEMAND WATER HEATER : RINNAI #2532-FFU(C) , or EQUAL -w/ MIN. 3/4ʺ Ø GAS SUPPLY & 3/4ʺ Ø CW SUPPLY.

PLUMBING FIXTURES

* NOTE :

MAX HW TEMPERATURE IS 120° F ;

HW THERMOSTAT IS NOT CONSIDERED CONTROL.

PLUMBING MATERIALS

WATER :

- BELOW GRADE ; SCHED 40 PVC

- ABOVE GRADE ; PEX - FLUSH LINE

BEFORE USE PER CPC 604.1.2

*INSULATE ALL HW LINES w/ MIN.

3/8ʺ th CLOSED CELL NEOPRENE

WASTE :

- BELOW GRADE ; SCHED ʹDWVʹ PVC

- ABOVE GRADE ; ʺ NO HUIS ʺ CAST IRON

VENTS : ABS w/ GALV. FLSHINGS

GAS : SCHED 40 BLACK STEEL

HOSE BIBS : BRONZE CAST, KEYLESS w/ GALV. NIPPLE

& w/ BACKFLOW PREVENTION.

Checked

Date

Scale

Randy OʹConnor

Owner :

Architect :

Nick Gilman

945012th St ʹEʹ

Paso Robles

805.238.3432

Ron Westbrook

W E

S T

C O

B U

IL

D

E R

S I

N C

03.20.2017

A D

A D

E T

A

IL

S

APPROPRIATE INFORMATION

MUST BE INCLUDED ON

SIGN (MINIMUM OF 1ʺ

IN HEIGHT)

LETTERING ON

SIGN MUST BE

A MINIMUM OF

1ʺ IN HEIGHT

UNAUTHORIZED VEHICLES

PARKED IN DESIGNATED

ACCESSIBLE SPACES

NOT DISPLAYING

DISTINGUISHING PLACARDS

OR SPECIAL LICENSE PLATES

ISSUED FOR PERSONS

WITH DISABILITIES

WILL BE TOWED AWAY AT

THE OWNERʹS EXPENSE.

TOWED VEHICLES MAY BE

RECLAIMED AT

OR BY TELEPHONING

1148 PASO ROBLES ST

226 9099

17" MIN.

M

IN

M

A X

M

A X

SANITARY

NAPKIN

DISPENSER

TOILET SEAT

COVER

DISPENSER

PAPER TOWEL

DISPENSER

DRYER

HAND

ELECTRIC MIRROR

2'X3'

LAVATORY/

SOAP DISPENSER

HIGHEST

OPERATING PART,

TYP.

S

T D

A

C C

E S

S

IB

L E

F

L U S

H H

A N

D L

E

" M

IN

" M

IN

" M A

X

" M A

X

INSULATED

TRAP, SMD.

24" MIN.

36" MAX.

T.O. SEAT

6"MAX.

12"MIN.

3'-0"

12"MAX.

54" MIN.

42" MIN.

1'-6"

"M A

X

O P

E R

A T

IN

G

C O

N T

R O

L S

LAVS: INSULATE WATER LINES AND DRAINS, PROVIDE 30"x48"

CLEAR FLOOR SPACE FOR FORWARD APPROACH - MAY

INCLUDE KNEE AND TOE SPACE.

FIRE EXT. IN

CABINET

PAPER

SEAT

DISPENSER

TOILET

PAPER

HOLDER

GRAB BARSOAP

DISPENSER

*URINAL

* URINAL SHALL HAVE ELONGATED RIM PROVIDING A

MINIMUM OF 13 1/2" FROM WALL.

COAT

HOOK

6" MIN.

TOE CLEAR

8" MIN.

KNEE CLEAR

6" MIN.

TOE CLEAR

ADA MOUNTING HEIGHTS

36"

PARKING

SPACE EMBLEM

(SEE BELOW)

1/2 RADIUS

BLUE

WHITE

REFLECTORIZED SIGN

CONSTUCTED OF

PORCELIAN STEEL

WITH BEADED TEXT

OR EQUAL

AREA OF SIGN TO BE

A MIN. CF 70 SQ. IN.

80ʺ MIN. TO TOP OF

WALKING SURFACE FOR

FREE STANDING SIGN -

60ʺ ON WALL OR FENCE

VAN ACCESSABLE

80ʺ MIN.

car

A. 18' minnimum length each parking space CBC 11B-502

B. 9' minnimum width each parking space CBC 11B-502

C. Minimum 18'x5' access aisle (passenger side) CBC 11B-502

D. Surface of the parking space(s) and access aisle(s) does not exceed 1:48 gradient (2%) in any direction CBC 11B-502.4

4' -0

8'-0"9'-0"

'-0

"NO PARKING"

WHITE - 12" HIGH LETTERS

min.min.

" VAN ACCESSIBLE "

PARKING SIGN

INTERNATONAL SYMBOL

OF ACCESSIBILITY

STALL EMBLEM

ACCESSIBLE ISLE

1) Disabled parking space must permit use of either car doors.

2) A parking bumper is required when no curb or barrier is provided which will prevent encroachment of cars over the adjoining accessible route.

3) Wheelchair users must not be forced to go behind parked cars other than their own to access an adjoining accessible route.

4) The maximum surface slope within the disabled parking space and adjacent access aisle may not exceed 2% in any direction.

5) Curb ramps may not encroach into the required dimensions of disabled parking space and adjacent access aisles.

6) Access aisle (loading / unloading area) must connect to an accessible path of travel to the facility.

GENERAL DISABLED PARKING SPACE NOTES :

ADA DOOR SIGNAGE

RESTROOM1. POLE OR WALL MOUNTED REFLECTORIZED SIGN, MIN 70” SQ INCHES AREA,

80 INCHES FROM BOTTOM OF SIGN TO PARKING SPACES FINISH GRADE,

DISPLAYING PROFILE VIEW OF WHEEL CHAIR WITH OCCUPANT IN WHITE OR

DARK BLUE BACKGROUND AND STATING VAN ACCESSIBLE, MIN. FINE $250.

2. POLE MOUNT 17” X 22” WITH 1” MIN LETTERING STATING:

“UNAUTHORIZED VEHICLES PARKING IN DESIGNATED ACCESSIBLE SPACES NOT

DISPLAYING DISTINGUISHED PLACARD OR LICENSE PLATES ISSUED FOR PERSONS

WITH DISABILITIES WILL BE TOWED AWAY AT OWNER EXPENSE. TOWED VEHICLES

MAY BE RECLAIMED AT OR BY TELEPHONING

(BLANK SPACES ARE TO BE FILLED IN WITH APPROPRIATE INFORMATION)

3. 36” X 36” SURFACE I.D. PROFILE VIEW OF A WHEEL CHAIR WITH OCCUPANT IN

WHITE ON BLUE BACKGROUND. LOCATED TO BE VISIBLE TO A TRAFFIC

ENFORCEMENT OFFICER WHEN A VEHICLE IS PARKED.

4. STRIPES AT 36” O.C. WITH WORDS “NO PARKINGʺ (12ʺ HIGH)

- 8’ WIDE VAN ACCESSIBLE.

5. CROSS SLOPE AT PAVING NOT TO EXCEED ¼” FT. PROVIDE 5’ X 5’ LEVEL LANDING

AT ENTRANCES AND EXIT WITH ¼” MAX OFFSET AT THRESHOLD.

6. POLE MOUNT TRAFFIC SIGN STATING “DO NOT ENTER-ONE WAY”

* VERIFY COMPLIANCES OF EXISTING H.C.

SIGNAGE AND SITE ACCESSIBILITY

*SITE H.C. SIGNAGE & NOTES

WALKS & SIDEWALKS

1. WALKS AND SIDEWALKS SHALL HAVE A CONTINUOUS COMMON SURFACE, NOT

INTERRUPTED BY STEPS OR BY ABRUPT CHANGES IN LEVEL EXCEEDING ½” AND

SHALL BE A MINIMUM OF 48” IN WIDTH. CBC #11B-303.

2. ABRUPT CHANGES IN LEVEL ALONG ANY ACCESSIBLE ROUTE EXCEEDING ½” SHALL

COMPLY WITH THE REQUIREMENTS FOR CURB RAMPS. CBC #11B-303.3

3. WHEN ABRUPT CHANGES IN LEVEL NOT EXCEEDING ½” OCCUR, THEY SHALL BE

BEVELED WITH A SLOPE NO GREATER THAN 1:2, EXCEPT THAT LEVEL CHANGES NOT

EXCEEDING ¼” MAY BE VERTICAL. CBC #11B-303.3.

4. WHEN THE SLOPE IN THE DIREVTION OF TRAVEL OF ANY WALK EXCEEDS 1 VERTICAL

TO 20 HORIZONTAL IT SHALL COMPLY WITH THE PROVISIONS OF CBC #11B-405. AS A

PEDESTRIAN RAMP.

5. WALK AND SIDEWALK SURFACE CROSS SLOPES SHALL NOT EXCEED ¼” PER FOOT.

6. WALKS, SIDEWALKS AND PEDESTRIAN WAYS SHALL BE FREE OF GRATING WHENEVER

POSSIBLE. FOR GRATING LOCATED IN THE SURFACE O ANY OF THESE AREAS, GRID

OPENINGS IN GRATING SHALL BE NO GREATER THEN ½” WIDE IN ONE DIRECTION. IF

GRATINGS HAVE ELONGATED OPENINGS, THEY SHALL BE PLACED SO THAT THE LONG

DIMENSION IS PERPENDICULAR TO THE DOMINANT DIRECTION OF TRAVEL. CBC

#11B-302.3.

7. WALKS SHALL BE PROVIDED WITH A LEVEL AREA NOT LESS THAN 60” BY 60” AT A

DOOR OR GATE THAT SWINGS TOWARD THE WALK AND NOT LESS THAN 48” WIDE BY

44” DEEP AT A DOOR OR GATE THAT SWINGS AWAY FROM THAT WALK. CBC #11B-404.

8. WALKS SHALL EXTEND A MINIMUM OF 24” TO THE SIDE OF THE STRIKE EDGE OF A

DOOR OR GATE THAT SWINGS TOWARD THE WALK. CBC #11B-404.2.4.1.

9. WALK AND SIDEWALK SURFACES SHALL BE SLIP-RESISTANT AS FOLLOWS:

CBC #11B-302.

PARKING

1. SURFACE SLOPES OF ACCESSIBLE PARKING SPACES SHALL BE THE MINIMUM

POSSIBLE AND SHALL NOT EXCEED 1 UNIT VERTICAL TO 50UNITS

HORIZONTAL IN ANY DIRECTION. CBC 11B 403.3.

2. THE WORDS “NO PARKING” SHALL BE PAINTED ON THE GROUND WITHIN

EACH LOADING AND UNLOADING ACCESS AISLE PER CBC 11B 502.3.3.

3. VAN ACCESSIBLE PARKING SPACES SHALL HAVE AN ADDITIONAL SIGN

STATING “VAN ACCESSIBLE” MOUNTED BELOW THE SYMBOL OF

ACCESSIBILITY AND POSTED AT A MINIMUM HEIGHT OF 80” FROM THE

BOTTOM OF THE SIGN TO THE PARKING SPACE FINISHED GRADE. CBC 11B 502.6

M

A X

MIN. FINE $250

NOTE :

INSTALL ON EXTERIOR WALL ADJACENT

TO ʺ VAN ACCESSIBLE ʺ SIGN.

7ʺ-9ʺ

ʺ

M

IN

M

A X

* BLUE PAINT @ Perimeter & Diagonals ( @ 36" o.c. )

3'-0"

TACTILE EXIT SIGNAGE

A. LETTERS ON SIGNS ARE RAISED 1/32”, SANS SERIF UPPERCASE CHARACTERS

AND ARE ACCOMPANIED BY GRADE 2 BRAILLE. CBC #11-B 703-2

B. RAISED CHARACTERS ARE BETWEEN 5/8” AND 2” HIGH. CBC #11-B 703-2.

C. BRAILLE DOTS ARE 1/10” ON CENTER IN EACH CELL WITH 2/10” SPACE BETWEEN

CELLS, MEASURED FROM THE SECOND COLUMN OF DOTS IN THE FIRST CELL

TO THE FIRST COLUMN OF DOTS IN THE SECOND CELL. CBC #11-B 703-3

D. BRAILLE DOTS ARE RAISED A MINIMUM OF 1/40” ABOVE THE BACKGROUND.

CBC #11-B 703-3.

E. CHARACTERS AND BACKGROUND OF SIGNS IS EGGSHELL, MATTE, OR OTHER

NON-GLARE FINISH. CBC #11-B 703-5

F. CHARACTERS CONTRAST WITH THEIR BACKGROUND (LIGHT CHARACTERS ON A

DARK BACKGROUND, OR DARK CHARACTERS ON A LIGHT BACKGROUND).

CBC #11-B 703-5.

G. SIGNS ARE INSTALLED ON THE WALL ADJACENT TO THE LATCH SIDE OF THE

DOOR (AT DOUBLE LEAF DOORS AND WHEN THERE IS NO WALL SPACE AT THE

LATCH SIDE, SIGNS SHALL BE PLACED ON THE NEAREST ADJACENT WALL,

PREFERABLE TO THE RIGHT). CBC #11-B 703.4.2.

H. MOUNTING HEIGHT IS 48" MIN. TO 60” MAX. FROM THE FINISH FLOOR TO THE

BASELINE OF THE SIGN. CBC #11-B 703.4.1.

Clear

To Edge of Water Closet

ADA TOILET REQUIREMENTS

Grabbar

1'

-6

3'-6"1'-0"

4'-0"

30ʺ x 48ʺ

Clear

2'-0"

12"m ax

5'-0"

5' -0

C le ar

T o

E d g e o f

S in k

NOTE : GRAB BAR REQUIREMENTS

The diameter or width of the gripping surfaces of a Grab bar shall be 1-1/4" to 1-1/2" , or the shape shall provide an equivalent gripping surface. If Grab bars are mounted on an adjacent wall, the space between the wall and the Grab bars shall be 1-1/2".

File details come from the government source that posted it. Updated .