About this file

Amendment 2 Wiring Diagram (pdf)

View the file

Other files

File Type Posted
DRAWINGS.pdf PDF
AMENDMENT 2.pdf PDF
Amendment 2 Wiring Diagram.pdf PDF
DAVIS BACON WAGES.docx DOCX document
Attachment 3 Site Visit Sign in Sheet.pdf PDF
SPECIFICATIONS.pdf PDF
Amendment 3.pdf PDF
AMENDMENT 1.pdf PDF
Attachment 3 Plan View.pdf PDF
Amendment 3 Plan Set.pdf PDF
Amendment 2 Specs.pdf PDF
Amendment 2 Drawings.pdf PDF
SOLICITATION.pdf PDF
AMENDMENT 2.pdf PDF
AMENDMENT 1.pdf PDF
Amendment 2 Specs.pdf PDF
Amendment 2 Drawings.pdf PDF
DRAWINGS.pdf PDF
SPECIFICATIONS.pdf PDF
DAVIS BACON WAGES.docx DOCX document
SOLICITATION.pdf PDF
DRAWINGS.pdf PDF
Amendment 2 Drawings.pdf PDF
Amendment 2 Wiring Diagram.pdf PDF
SOLICITATION.pdf PDF
SPECIFICATIONS.pdf PDF
AMENDMENT 1.pdf PDF
Amendment 2 Specs.pdf PDF
DAVIS BACON WAGES.docx DOCX document
SPECIFICATIONS.pdf PDF
DRAWINGS.pdf PDF
SOLICITATION.pdf PDF
DAVIS BACON WAGES.docx DOCX document
AMENDMENT 1.pdf PDF
SOLICITATION.pdf PDF
DAVIS BACON WAGES.docx DOCX document
SPECIFICATIONS.pdf PDF
DRAWINGS.pdf PDF
Show all 38

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

H

G

F

E

D

C

B

A

H

G

F

E

D

C

B

A

8 1234567

8 1234567

FEDERAL AVIATION ADMINISTRATION

DEPARTMENT OF TRANSPORTATION

REV DATE DESCRIPTION JCN

REDLINE

DATE

APVD

REV

ISSUED BY

REVIEWED BY

SUBMITTED BY APPROVED BY

DATE:

EW

DRAWING NO.

DESIGNED BY:

DRAWN BY:

CHECKED BY:

JCN

WASD-D-PAPILED-Q758-010

WASHINGTON, DC

DG

JO

STANDARD INSTALLATION DRAWINGS FOR

(PAPI) SYSTEM FA-30200

LIGHTING SYSTEM TEAM

AJM-322

PAPI PCA/LHA WIRING DIAGRAM

AND DETAILS

AIR TO GROUND CONTROL

ELECTRICAL SYSTEM WIRING DIAGRAM

TB

SPLICE IN

SPLICE CAN

PCA

4-1/C #10,600V

LHA

TVSI

4C #14

(TYP. FOR EA. LHA)

SPLICE CAN

WATER PROOF SPLICE

GROUND LUG

CONDULET WIRING DETAIL

SIGNAL LINE

TO EQUIPMENT CASE

TERMINAL

STRIP

INSULATION

SIZE: 16 AWG OR LARGER

LENGTH: 2 INCHES OR LESS

A

NOT TO SCALE010

GROUNDING OF OVERALL CABLE SHIELD

APPROVED STD. 019E

GROUNDING CLAMP

NOT TO SCALE

NOT TO SCALE

RV3

1 1 2

LHA

#4

ASSEMBLY

CONTROL

POWER AND

TB6

E2 31 2

LHA

LHA

#3

#2

#1

2LHA

TVS1

TVS2

RV1

G

FROM POWER

SEE: Q758-003

SERVICE

INPUT POWER 5 KVA

120/240 VAC 60HZ

1-1/C #6 BARE

L1

L2

N

3-1/C #8 600V

G

P6

P5

TB1

E1

TB2

TVS1

TB3

TVS1

TB4

TVS1

TB5

TVS2

G

TVS2

G

TVS2

G

2-2 PR SHIELDED #19: GROUND SHIELD FROM

SHIELDED WIRE IS ATTACHED TO GROUND IN LHA,

BUT NOT IN PCA. IN PCA, SHIELD IS TAPED

BACK AND NOT USED (PREVENTING A GROUND

LOOP).

E2

E1

NOTE:

LHA POWER AND CONTROL WIRING ENTER THE REAR OF

EACH UNIT (SHOWN HERE ON OPPOSITE SIDES FOR CLARITY)

SEE -008 OF THIS SET

FOR CONTINUATION

1.

2.

NOTE 1

NOTE 1

NOTE 1

NOTE 1

4-1/C #10,600V

1-#6, GND 600V (GREEN)

TYP TO EACH LHA

SPLICE CAN AND POWER/CONTROL

SPLICE CANS

IN LHA FOUNDATION

POWER CONTROL

B

C

D

(TYP. AT EACH LHA)

CONNECTORS BY "SURE SEAL"

CONNECTORS OR EQUIVALENT.

BREAKAWAY

CONNECTION

SPLICE CAN

AT LHA

N

E U T

N E

U T

L

L

G N D

120/240V INCOMING POWER

PER SITE SPECIFIC PLANS

METER BASE PER LOCAL UTILITY

REQUIREMENTS

WEATHERPROOF UL LISTED

INSULATED GROUNDING BUSHING

(TYP ALL METALLIC CONDUITS)

STEP UP XFMR

5KVA, 240/480V

1-PHASE, 60HZ, SEALED

STEP DOWN ISOLATION

TRANSFORMER

5KVA, 480V-120/240V, 1-PHASE

60 HZ, SEALED

GROUNDING ELECTRODE

CONDUCTOR (G/E/C)

#2 AWG B/C, 1" PVC SCH. 40

(OR LARGER IF REQ’D BY CODE)

2#8, 1#8 GND

2"C

2 #10, 3/4" RGSC

TYPICAL 120/240V ELECTRICAL POWER SERVICE

SPD

120/240V 1-PHASE

L1-G, L2-G, N-G

PROTECTION - SEE NOTE 8

(DIRECT CONNECTION)

NOT TO SCALE

TO PAPI PCA

(LED PAPI 6.25 AMPS +15 AMPS GFI

MAX LOAD - RRGS IF APPLICABLE)

SEE NOTE 7

SEE D/010 FOR CONTINUATION

N

E U T

N E

U T

L

L

G N D

100A DISCONNECT SWITCH

SIMILAR TO SERVICE

ENTRANCE SWITCH ABOVE

#2 C/E/C

SIMILAR

TO ABOVE

3 #2, 1 #2 GND

1-1 1/2" RGGSC

2 #1 #8 GND

RGSC

TRANSFORMERS

AND SWITCHES

IF REQUIRED

TO LIMIT

VOLTAGE DROP

SEE NOTE 7

2 #10, 1#10G, 1"G

DISCONNECT SWITCH

100A, 600V, 15A, 600V FUSING

NEMA 3R, 2 POLE, HEAVY DUTY

LOCAL DISCONNECT SWITCH

100A, 600V, NON-FUSED

NEMA 3R, 2 POLE, HEAVY DUTY

TO

LHA

TO

LHA

LEAVE SUFFICIENT SLACK

TO PERMIT COVER REMOVAL

(6’ MIN)

4C #14 AWG, 600V CORD

W/ FEMALE RECEPTACLE END

AMERACE #95-04MRJ

4-1/C POWER

FROM PCA

CONTROL

FROM PCA

PLUG AND

RECEPTACLE TO FORM

BREAKAWAY CONNECTION

4C #14 AWG, 600V CORD

W/ MALE PLUG END

AMERACE #95-05MPJ

CONNECT

SERVICE ENTRANCE SWITCH-100A 2 POLE,

3 WIRE, SIN, HEAVY DUTY, NEMA 3R,

FUSIBLE, LOCKABLE

IN BOTH ON & OFF POSITIONS LABEL

"FAA R/W XX PAPI - 120/240V 1O"

30A, 200K, DUAL ELEMENT

TIME DELAY FUSING

REQUIRED BY SPECIFICATION FAA-C-1391.

3. ARMORED CABLES MAY BE REQUIRED IN LIEU OF THE SINGLE CONDUCTOR

NON-ARMORED CABLES SHOWN.

4. INSTALL CABLE MARKERS AT 200’ SPACING ON RUNS OVER 200’ IN LENGTH

AND AT LOCATION OF CHANGE OF DIRECTION ON CABLE RUN AND AT SPLICES AS

5 SHOW EXISTING D.E.B. CABLE IN PAPI CONSTRUCTION AREA.

7. WHEN THE DISTANCE BETWEEN POWER SOURCE AND THE CONTROL UNIT

EXCEEDS 400’, CABLE LARGER THAN #8 CAN BE USED FOR 120/240V

IF NECESSARY TO MAINTAIN VOLTAGE REGULATION 600V STEP UP/DOWN

XMRS MAY BE USED IN LIEU OF 480V.

MOUNTING RAILS AND HARDWARE.

SURGE PROTECTIVE DEVICE (SPD) SHALL CONFORM TO THE REQUIREMENTS OF

FAA-STD-019 (LATEST EDITION).

6. A 1/0 BARE COPPER GUARDWIRE COMPLETE WITH 3/4" X 10’ GROUND

SERVICE EXTENSION. INPUT VOLTAGE TOLERANCE SHALL BE +/- AT THE-PCA

SITE CONDITIONS MAY REQUIRE LARGE POWER CONDUCTORS

- REFER TO NOTE 1, SHT. 003

8.

9.

CABLE (DET. D, 0758-004)

RODS SHALL BE INSTALLED 1’ ABOVE ALL NON-METALLIC NON-ARMORED

IN SEVERE MOIST OR SALT LADEN ATMOSPHERES, INSTALL NEMA 4X

STAINLESS STEEL

PROTECTION DEVICES, ENCLOSURES

TRANSFORMER, DISCONNECT SWITCH, AND SURGE

INDIVIDUAL LINE SHIELDS

AND UNSUSED CONDUCTORS

OVERALL SHIELD

GROUND AT BOTH ENDS

INDIVIDUAL LINE SHIELDS

OR UNUSED CONDUCTORS

AND UNUSED CONDUCTORS TO TERMINAL STRIP

POWER

CONDULET

CONTROL

CONDULET

E2 E2

E2 E2

E2 E2

E2 E2

12/30/2015

3#10, #10G

3/4" RGSC

DETAIL-PCA TO LHA WIRING