8 7

H

G

F

E

QRC

D

C

B

A

8 7

6 5 4 3

ARSR BENTON,PENNSYLVANIA

FIRE PROTECTION AND

MODIFICATIONS LIFE SAFETY

DRAWING NO.

QRC-1505568-G003

QRC-1505568~D008

QRC-1505568~A001

QRC-1505568-A002

QRC-1505568-A003

QRC-1505568-A004

QRC-1505568-A00S

0RC-1505568~A006

ORC-1505568-F001

QRC-1505568~F002

0RC-1505568-F003

QRC-1505568-F004

0RC-1505568-F00S

QRC-1505568-F006

ORC-1505568-F007

DESCRIPTION

REV. DATE

09/13/2017

09/13/2017

09/13/2017 09/13/2017 09/13/2017 09/13/2017 09/13/2017 09/13/2017

09/13/2017 09/13/2017 09/13/2017 09/13/2017 09/13/2017 09/13/2017 09/13/2017

DESCRIPTION

ARSR

ARSR

ARSR

ARSR

ARSR

ARSR

ARSR

ARSR

ARSR

ARSR

ARSR

ARSR

ARSR

ARSR

ARSR

COVER SHEET, DRAWING INDEX AND LOCATION MAP

DEMOLITION UPGRADES

FIRST FLOOR LIFE SAFETY UPGRADES

SECOND FLOOR LIFE SAFETY UPGRADES

THIRD FLOOR LIFE SAFETY UPGRADES

FOURTH FLOOR LIFE SAFETY UPGRADES

FIFTH FLOOR LIFE SAFETY UPGRADES

MEZZANINE LEVEL LIFE SAFETY UPGRADES

FIRST FLOOR FIRE ALARM UPGRADES

SECOND FLOOR FIRE ALARM UPGRADES

THIRD FLOOR FIRE ALARM UPGRADES

FOURTH FLOOR FIRE ALARM UPGRADES

FIFTH FLOOR FIRE ALARM UPGRADES

MEZZANINE LEVEL FIRE ALARM UPGRADES

FIRE DOOR UPGRADES

2 1

. ······~~.!f~l-~· .. t~r: ·· .. t;;t;·· .

Er!W~~ · B e nt o n ...... / ....... .Jr--.

H

G

F

LOCATION MAP

NOT TO SCALE

E

D

C

REV APPROVED

DATE

DESCRIPTION JCN REDL NE AP'lll B

DATE

DEPARTMENT OF TRANSPORTATION

FEDERAL AVIATION ADMINISTRATION ~ ,...

ATO - TECHNICAL OPERATIONS EASTERN SERVICE AREA ~

ARSR

FIRE AND LIFE SAFETY MODIFICATIONS

COVER SHEET, DRAWING INDEX

AND LOCATION MAP

BENTON

REVIEWED BY SUBM TTEO BY APPRCVED BY

cZr.

PA

I V> z

LL

fi3 v1

A

ISSUED BY DAff JCN

======:DR=Al=VN=====~~=: £Nr~}~EfJ~iut\i~~[S b.:0R=Aw=1NG,---'~=0

/'-"l

...L_ __ l=

0"-"

R~~~

CHECKED QRC-1505568-G003

6 5 4 3 2 1

G

F

E

D

C

B

A

8 7

STORAGE

rREMOVE ONE ABANDONED

ELECTRICAL CONDUIT

i, THROUGH WALL OPENING

OVER DOOR TO ROOM

v- DEMO AND REPLACE

EXISTING DOORS

DEMO EXISTING HV AC EQUIPMENT AND FRAMES;

. IN MAIN AREA AND DUCTWORK /

I/I/

COORDINATE WITH

EQUIPMENT THAT PENETRATES THE FIRE DOORS

WALL OF THE STORAGE ROOM AND IL UPGRADES DRAWINGS

THE GENERATOR ROOM;DEMO POWER

EQUIPMENT, CONDUIT, CIRCUITS, v -rv ETC. FOR HVAC LOCATED IN STORAGE V

ROOM; COORDINATE WITH SCOPE OF

1 n

WORK DOCUMENT AND THE LIFE ~

SAFETY UPGRADES DRAWINGS -s:,-.

LDEMO AND REPLACE ~

1'------ EXISTING DOORS,

)'---.._ FRAMES AND WALL

-l r SE_CTIQN; COORDINATE

"' IRE DOORS

DEMO AND REPLACE EXISTING DOORS _.,. )>f UPGRPfiS DRAWINGS

AND FRAMES; COORDINATE WITH LIFE ( \

SAFETY UPGRADES DRAWINGS

DEMO EXISTING HVAC EQUIPMENT L---AND DUCTWORK THAT PENETRATES GENERATOR

THE WALL; COORDINATE WITH SCOPE ~ OF WORK DOCUMENT AND THE LIFE

SAFETY UPGRADES DRAWINGS ~

DEMO AND REPLACE EXISTING DOORS

BOILER

AND FRAMES; COORDINATE WITH FIRE

DOORS UPGRADES DRAWINGS

,M I\ -- ;>- ~L)-Li\ 1/4 ~. I I\ DN -~- ---------

WIRE ' i CHASE BOILER

CLOSET I TREATMENT

ROOM ! I I

UP LOBBY

i L) L)

FIRST FLOOR PLAN

SCALE: 1/8"=1'-0"

RADAR EQUIPMENT ROOM

~-- REMOVE EXISTING REFRIGERATOR:

DRAWINGS

COORDINATE WITH LIFE SAFETY UPGRADES

l11======c+=-===;--;==== / I~

KITCHEN

1 1\r1 p I c

WIRE

CHASE

CLOSET

I\ I\

OFFICE

OFFICE LJ

FOURTH FLOOR PLAN

SCALE: 1/8"e1'-0"

I

6 I 5

OFFICE _) OFFICE !\_EXISTING CONCRETE WALL TO REMAIN

bfv1

WIRE

CHASE

CLOSET

WIRE

CHASE

CLOSET

STORAGE

1r:

--1 ii, 1111

I I I ,11 ~J.,_J.,_,i,.~

Ii

Ti I I

,!! I I ..J I

-DEMO EXISTING WOOD CONSTRUCTION, PANELBOARD

, ;.. WALLS, DROP CEILING; AND ELECTRICAL TO NEAREST

JUNCTION BOX INCLUDING: 2 LIGHT SWITCHES:

2 TELEPHONE JACKS: 5 ELECTRICAL OUTLETS: AND

8 LIGHTS: CUT BACK 3 EXISTING HVAC SUPPL YS AND

RETURNS TO DUCT ABOVE: COORDINATE REMOVAL /

fr

RELOCATION OF FIRE ALARM SYSTEM EQUIPMENT

WITH FIRE ALARM SYSTEM UPGRADES DRAWINGS

i"<-DEMO EXISTING

WOOD .WALLS

AND DOOR

i

. MECHANICAL / STORAGE

DEMO THREE ABANDONED

PIPES THROUGH THE FLOOR:

COORDINATE FIRESTOPPING WITH

LIFE SAFETY UPGRADES DRAWINGS

I

REMOVE 4' x 8' CORK BOARD I

I\ \, LOCKER s H'IAC UNIT

ROOM

L DEMO EXISTING

\ WOOD WALLS AND

DOOR <APPROX.

60"x 91")

ON\_ ~ r\_

BATHROOM

UP

SECOND FLOOR PLAN

SCALE: 1/8"=1'-0"

\__84"x 90" WOOD COVERING EXTERIOR

WALL; TO BE REMOVED AS PART OF FIRE

ESCAPE PROJECT

STORAGE

REMOVE 12"x 12" PIECE

OF MASONITE: COORDINATE

WITH LIFE SAFETY

UPGRADES DRAWINGS\

.,_ DEMO EXISTING WOOD

WALLS AND DOOR

REMOVE 48"x 60" PIECE OF

PLYWOOD FROM WALL 7

DEMO EXISTING WOOD

CONSTRUCTION, WALLS;

RELOCATE 1 LIGHT SWITCH

TO COLUMN; REMOVE AND

RELOCATE COMBUSTIBLE

STORAGE TO FIRST FLOOR

SJ..ORAGE ROOM

DN ~

j\

BATH

i UP

FIFTH FLOOR PLAN

SCALE: 1/8"=1'-0"

6 5

WIRE

CHASE

CLOSET

124" X 129" PIECE OF FIBER BOARD

COVERING EXTERIOR WALL; TO BE

REMOVED AS PART OF FIRE ESCAPE

PROJECT

~ DEMO EXISTING WOOD

CONSTRUCTION, WALLS, DOORS, AND

DROP CEILING: AND ELECTRICAL TO

NEAREST JUNCTION BOX INCLUDING:

1 LIGHT SWITCH: AND 6 LIGHTS:

CUT BACK EXISTING HV AC SUPPLY

TO DUCT ABOVE: COORDINATE

REMOVAL / RELOCATION OF FIRE

ALARM SYSTEM EQUIPMENT WITH

FIRE ALARM SYSTEM UPGRADES

DRAWINGS

~-14UP

THIRD FLOOR PLAN

SCALE: 1/8"=1'-0"

METAL GRATE

Ii

WALKING SURFACE

i

:L N .L.

MACH RM. . .

UP

E

MEZZANINE PLAN

SCALE: 1/8"=1'-0"

8' 0 w-----.- 8'

SCALE: 1/8" = 1'-0"

16'

.,1.

"' I ii ijl

~I I

REV APPROVED

DATE

2 1

DESCRIPTION JCN

DEPARTMENT OF TRANSPORTATION

FEDERAL AVIATION ADMINISTRATION

REDLINE

DATE

ATO - TECHNICAL OPERATIONS EASTERN SERVICE

ARSR

FIRE AND LIFE SAFETY MODIFICATIONS

DEMOLITION UPGRADES

BENTON

REVIEWED BY SUBMITTED SY APPROVED BY

APVD

AREA

PA

DESIGNED ISSUED BY DATE

t------+-----+-DR~A-W-N ----~RP'-' ENGINEERING SERVICES r-D""'RA~w~,N~G ~N~O ~~~~---- 1=5=0=5i'=

R "'E~~-

ChECKED LW INFRASTRUCTURE QRC-1505568-D008

2 1

H

G

F

E

D

C

B z g => a:

I-

"' z ii:.

0 u..

w

C

A~ C C

' oc C

' 1 C

F

E

D

C

B

A

8 7 6 5 4 3

~-FIRESTOP CONDUIT ~· I THROUGH CEILl:G

FIRESTOP 6 CONDUITS

AND 1HOLE THROUGH

CEILING

~-COORDINATE LOCATION OF EMERGENCY LIGHT /\ J "- WITH NEW FIRE ESCAPE TO BE CONSTRUCTED

• UNDER DIFFERENT PROJECT

AROUND COLUMN FIRESTOP

I - '

FIRESTOP VARIOUS PENETRATIONS THROUGH WALL

INCLUDING: 2 CONDUITS; 1 INSULATED PIPE;

LARGE DUCT; 7 CONDUITS; 1 CONDUITS; 1 HOLE; _,,,

3 CONDUITS; 1 CONDUIT; LARGE DUCT; AND /

HEAD-OF WALL ALONG ENTIRE LENGTH OF WALL _ _,,

REBUILD CONCRETE BLOCK

WALL WHERE 16 "x 28" / DUCTWORK IS BEING

REMOVED; SEAL ALL JOINT

TO MAINTAIN FIRE RATING

VARIOUS PENETRATIONS THROUGH

CEILING, INCLUDING: 1 HOLE; 1

CONDUIT, AND 1 PIPE

REBUILD CONCRETE BLOCK

FIRESTOP INSULATED WALL WHERE 16"x 28"

PIPE THROUGH DUCTWORK IS BEING / CEILING REMOVED; SEAL ALL JOINT

TO MAINTAIN FIRE RATING

STORAGE

PROVIDE BARRIER TO UNDERSIDE OF THE

24"X24" STEEL PLATE THAT COVERS A

LARGE SQUARE HOLE IN THE CEILING TO

RESIST THE PASSAGE OF SMOKE; EDGES

AND HOLES AROUND BOLTS/ HANDLES

WITH ADHESIVE BACKED GRAPHITE

~ INTUMESCENT SEAL AND A CONTINUOUS

BEAD OF INTUMESCENT CAULK OR

PUTTY;REFER TO SCOPE OF WORK

DOCUMENT FOR MORE INFORMATION

FIRESTOP VARIOUS

PENETRATIONS THROUGH THE

CEILING INCLUDING: 2 HOLES; 1

CONDUIT; 1 INSULATED PIPE;

AND 2 HOLES AT COLUMN

FIRESTOP VARIOUS

I

) PENETRATIONS CREATED BY

DEMOLITION OF EXISTING

EQUIPMENT IN THIS ROOM; I.E.,

INSULATED PIPES, CONDUITS

6 PIPES, AND DUCTWORK THR UGH

WALLS AND CEILING (DEMOLITION

UNDER A SEPARATE FAA

Iii

Ir- REMOVE EXISTING DOOR, FRAMES AND

STEEL WALL BETWEEN DOORS MEASURING

APPROXIMATELY 48"x 84" x 6". REBUILD

FIRE RATED WALL WITH CMU BLOCK.

FIRESTOP JOINTS AND SEAMS WHERE NEW

WALL MEETS EXISTING CONSTRUCTION.

FIRESTOP VARIOUS SQUARE

HOLES IN CEILING WHERE

THREADED RODS HOLDING

EQUIPMENT PENETRATE -

APPROXIMATELY 10 LOCATIONS

MULTIPLE LOCATIONS

PROJE~ /

.--1.1-"'-- FIRESTOP APPROXIMATELY 14 CONDUITS AND

5 INSULATED PIPES; FIRESTOP THE

HEAD-OF-WALL ALONG THE ENTIRE

./ - LENGTH OF THE WALL

• FIRESTOP VARIOUS PENETRATIONS ~ REBUILD CONCRETE BLOCK WALL WHERE 2

LARGE SQUARE HOLES EXISTS: REMOVE

INSULATED PIPE PENETRATION THROUGH

ONE; HOLES MEASURE APPROXIMATELY 16"

INST ALL SIGN STATING

"DOORS TO REMAIN

CLOSED AT ALL TIMES.

NO STORAGE PERMITTED" -----11++1-~

AROUND COLUMN FIRESTOP

VARIOUS PENETRATIONS

THROUGH CEILING,

INCLUDING: 1 HOLE

AND 3 CONDUITS-----

THROUGH WALL INCLUDING:

2 CONDUITS; 2 CABLES: LARGE DUCT:

7 CONDUITS; HOLE WHERE IS

MISSING; AND HEAD-OF-WALL /

ALONG ENTIRE LENGTH OF WALL_/

AROUND COLUMN FIRESTOP

VARIOUS PENETRATIONS

THROUGH CEILING,

INCLUDING: 1 HOLEh

FIRESTOP VARIOUS PEN~IONS

THROUGH WALL INCLUDING: 1 GREEN

FIRESTOP HEAD-OF-WALL AT CONDUIT; 1 CONDUITS; 2 INSULATED

STRUCTURAL MEMBER AND PIPES; 3 CONDUITS; 3 WIRES;

STEEL ANGLE IRON 3 CONDUITS; AND HEAD-OF-WALL

II\

\IJ

FIRESTOP HOLE AND ALONG ENTIRE LENGTH OF WALL-===l\.--l.1-

COMPLETED 2-HOUR FIRE

RESISTANCE RATED WALL CONDUIT THROUGH WALL FIRES TOP HOLE THROUGH WALL ~

CONSTRUCTION ABOVE DOOR •

<CMU, GYPSUM OR APPROVED FIRESTOP 2 CONDUITS; FIRESTOP WIRE

EQUAL); FIRESTOP ALL HOLE; 2 INSULATED THROUGH WALL----, ~.,

PENETRATING ITEMS THROUGH PIPES; AND 2 CONDUITS ~~ FIRESTOP CONDUIT REMOV> THE

WALL INCLUDING MULTIPLE ' THROUGH WALL '-----. THROUGH WALL DOOR TOP

CONDUIT PENETRATIONS ---H-1+-h'.. 1'----..

• J FROM ~:::-~ l-l1-~jc_,:_:_=_~'.:_:,~=f.~~~~~~~~~~~-~--~--:=------=-·-::5s-,-;f~~;~~~---,---,'~,--,-----A,-A,,-

I

GENERATOR

REBUILD CONCRF~TE BLOCK

WALL WHERE 1sT "x 60"

DUCTWORK IS B TNG

REMOVED; SEAL ALL JOINTS

TO MAINTAIN FIRE RATING

II

II

x 16"; SEAL ALL JOINTS TO MAINTAIN FIRE RATING

CUT HOLES AS REQUIRED IN EXTERIOR WALL

AND INST ALL MAKE-UP AIR AND EXHAUST

EQUIPMENT; COORDINATE WITH THE SCOPE

OR WORK DOCUMENT FOR MAKE,MODEL

NUMBERS, AND ADDITIONAL INFORMATION

ASSOCIATED WITH THE INSTALLATION OF

SUCH EQUIPMENT; COORDINATE LOCATION

OF HOLES TO BE CUT AND EQUIPMENT TO

BE MOUNTED WITH THE FAA ON-SITE

11 w-- REBUILD CONCRETE BLOCK WALL

WHERE DUCTWORK IS BEING

REMOVED; SEAL ALL JOINTS TO

MAINTAIN FIRE RATING

BOILER

EXISTING 2'-6" LOUVER

TO REMAIN. BOILER ROOM,

AND ADJACENT ROOM AND

rll--lll--- FIRESTOP VARIOUS PENETRATIONS THROUGH

( J CEILING INCLUDING: 2 INSULATED PIPES; 2

INSULATED PIPES; 3 CONDUITS; AND

1 INSULATED PIPE

BOILER TREATMENT ROOM

OF SIMILAR HAZARD

AND WILL BE OPEN TO

ONE ANOTHER \J

INST ALL "LOW HEADROOM'

SIGN ON THE WALL INSIDE N\ ON

.___1---, 11===a----1-------<I

THE EXIT ST AIR------------+- ~

II

WI/?£

CHASE

CLOSET

INSTALL PADDING ON THE BOT_T_O_M ____ ___,/1'11 ~ J

OF THE HANDRAIL STANCHION L_/

I

ELEV.

ABOVE THE ENTRY LOBBY FIRESTOP

VARIOUS PENETRATIONS THROUGH

CEILING ABOVE INCLUDING: 2 CABLES;

APPROXIMATELY 10 INSULATED PIPES;

FIRESTOP 2 CONDUITS THROUGH CEILING

TO LOBBY BELOW; FIRESTOP INSULATED

PIPE INTO BOILER ROOM -----~

LOBBY ~

FIRESTOP 2'.i~

CONDUITS >-

THROUGH _

WALL -

4 :sz f>

1 1 t - --

-REMOVE WOOD

COVERING

WINDOW AND

REBUILD THE

MASONRY WALL

APPROX. 20"x 3( "

FIRESTOP ALL '-

BOILEF<

TREATMENT

F<OOM

SEAMS AND

JOINTS ~ ~

A,~,',~_@, '-'I De. Iv ~

EXISTING 2'-6"x 3'-0~1'--,,_

LOUVER TO REMAIN

~ FIRESTOP HOLE

THROUGH WALL AT

STRUCTURAL MEMBER

1 FIRST FLOOR PLAN

AOO

SCALE: 1/4" = 1'-0"

,1.,- FIRESTOP VARIOUS PENETRATIONS THROUGH

CEILING INCLUDING: 2 INSULATED PIPES AND

2 HOLES

-- INST ALL SIGN IDENTIFYING

FIRE HYDRANT " NOT IN USE"

2 1

LIFE SAFETY LEGEND

HEAD-OF-WALL FIRESTOPPING REQUIRED

IEXITI EXIT SIGN

'7=:;:::i EMERGENCY LIGHT - OUTDOOR UNITS TO BE

WEATHERPROOF AS INDICATED IN SCOPE OF

WORK DOCUMENT

LIFE SAFETY NOTES

1, EXISTING PENETRATIONS NOTED ARE BASED ON VISUAL

OBSERVATIONS DURING SITE SURVEY ONLY.

2, CONTRACTOR SHALL BE RESPONSIBLE FOR SEALING ALL

PENETRATIONS THROUGH ALL FIRE OR SMOKE RESISTANCE

RATED CONSTRUCTION INDICATED ON THIS SHEET WITH A UL

CLASSIFIED THROUGH-PENETRATION FIRE-STOP ASSEMBLY

AND/ OR HEAD-OF-WALL JOINT SYSTEM, WHETHER THE

PENETRATION IS SPECIFICALLY INDICATED OR NOT.

3. NEW PENETRATIONS CREATED BY FIRE ALARM SYSTEM WORK

AND ANY OTHER WORK ASSOCIATED WITH THIS FIRE LIFE

SAFETY UPGRADE MUST ALSO BE SEALED BY THE CONTRACTOR

AS PART OF THIS UPGRADE.

REV .ePPROVED

DAE DESCRIPTION JCN

DEPARTMENT OF TRANSPORTATION

FEDERAL AVIATION ADMINISTRATION

RECLINE

DATE APVD

A TO - TECHNICAL OPERATIONS EASTERN SERVICE AREA

ARSR

FIRE AND LIFE SAFETY MODIFICATIONS

FIRST FLOOR

LIFE SAFETY UPGRADES

BENTON

REVIEWED BY SUBMITTED BY

PA

DESIGNED ISSUED BY DAT JCN

r------7---i-__j-oR-AW_N ___ _JR1E__IP ENGINEERING SERVICES boRcccAw=1Ncc-G -°"~0c"--'91-"13=1=20"--'-17 '-L__-----'-'

15=0,55 ""'R~"'-I~

HUGHES CHECKD LW INFRASTRUCTURE QRC-, 1505568-A001

8 7 6 5 4 3 2 1

H

G

F

E

C

B z Q t-- :::> a::

t--z ii 0 ...

Cl w

!!l

A

F

E

D

C

B

A

INST ALL SIGN STATING "DOORS

TO REMAIN CLOSED AT ALL

I

OFFICE OFFICE

STORAGE

PROVIDE BARRIER TO THE

UNDERSIDE OF THE FOUR

24"x 24" STEEL PLATES

THAT COVER LARGE SQUARE

HOLES IN THE FLOOR TO

RESIST THE PASSAGE OF

SMOKE;EDGES AND HOLES

AROUND BOLTS/ HANDLES

WITH ADHESIVE BACKED

GRAPHITE INTUMESCENT SEAL

AND A CONTINUOUS BEAD OF

INTUMESCENT CAULK OR

PUTTY;REFER TO SCOPE OF

WORK DOCUMENT FOR MORE

INFORMATION

FIRES TOP VARIOUS PENETRATIONS

THROUGH FLOOR INCLUDING: 2

CONDUITS AND 1 PLASTIC PIPE -~""

6 5 • 4

COORDINATE EMERGENCY LIGHTS AND EXIT

SIGN WITH NEW FIRE ESCAPE TO BE

ADDED UNDER DIFFERENT PROJECT

A ~

I I

EXIT

~-COVER 33"x 74" PIECE

WOOD WITH INTUMESCENT

OR FIRE RETARDANT PAINT

COVER 3 1/2"x 17 1/2"

EXISTING PIECE OF WOOD

WITH INTUMESCENT OR FIRE

RETARD ANT PAINT

C l/ FIRESTOP 3 CONDUITS r THROUGH FLOOR

. MECHANICAL / STORAGE

FIRESTOP CONDUIT

() THROUGH FLOOR

I lf---------------''U V

LOCKER

ROOM

FIRESTOP HEAD-OF-WALL AT

STRUCTURAL MEMBER AND

STEEL ANGLE IRON --. TIMES. NO STORAGE PERMITTED" ---1tt-tt-y--..

1rn11'--==--=·=-~~t~~~I ~I ~I \~, ~~~=t--h

FIRESTOP ALL PENETRATING ITEMS

THROUGH WALL INCLUDING CABLES,

CONDUITS, PLASTIC PIPES

WIRE

CHASE

CLOSET

11 I I I I \~ I _._-+-->-+-~DN

II I I I I if\ 111 l_ J_ ..L _j_ J_

'11 flrF-~ ""§c~,s_ ~~~~~§[______, j- 111 lbL""--7~;=~~~~~~~ <f- 111 T 1 - '1

111 I I 111 I I k---J_J_ _________ =

----+---+-+--! UP

EL£'/.

@SECOND FLOOR

4'

SCALE: 1/ 4" = 1'-0"

7 I 6 I

BATHROOM

PLAN

8'

,,-.,,------ FIRESTOP VARIOUS

/.,,- PENETRATIONS THROUGH

~ FLOOR INCLUDING:

5 PLUMBING PIPES AND

TWO HOLES

+ 4

I

FIRESTOP VARIOUS PENETRATIONS THROUGH

FLOOR INCLUDING: 9 PIPES AND 3 CABLES

HUGHES

I 3 I

2 1

LIFE SAFETY LEGEND

HEAD-OF-WALL FIRESTOPPING REQUIRED

EXIT SIGN

EMERGENCY LIGHT - OUTDOOR UNITS TO BE

WEATHERPROOF AS INDICATED IN SCOPE OF

WORK DOCUMENT

LIFE SAFETY NOTES

1. EXISTING PENETRATIONS NOTED ARE BASED ON VISUAL

OBSERVATIONS DURING SITE SURVEY ONLY.

2. CONTRACTOR SHALL BE RESPONSIBLE FOR SEALING ALL

PENETRATIONS THROUGH ALL FIRE OR SMOKE RESISTANCE

RATED CONSTRUCTION INDICATED ON THIS SHEET WITH A UL

CLASSIFIED THROUGH-PENETRATION FIRE-STOP ASSEMBLY

AND/ OR HEAD-OF-WALL JOINT SYSTEM, WHETHER THE

PENETRATION IS SPECIFICALLY INDICATED OR NOT.

3. NEW PENETRATIONS CREATED BY FIRE ALARM SYSTEM WORK

AND ANY OTHER WORK ASSOCIATED WITH THIS FIRE LIFE

SAFETY UPGRADE MUST ALSO BE SEALED BY THE CONTRACTOR

AS PART OF THIS UPGRADE •

REV APPROVED

DATE DESCRPTON JC~

DEPARTMENT OF TRANSPORTATION

FEDERAL AVIATION ADMINISTRATION

RECLINE

DATE APVD

ATO - TECHNICAL OPERATIONS EASTERN SERVICE AREA

ARSR

FIRE AND LIFE SAFETY MODIFICATIONS

SECOND FLOOR

LIFE SAFETY UPGRADES

BENTON

REVIEWED sv SUBMITTED BY

PROJECT ENGINEER 'MGR: ENGINEERING C 'NTER A

PA

DESIGNED

RP

ISSUD BY DATE JON

ENGINEERING SERVICES DRAWING ~0

911312017

INFRASTRUCTURE QRC- 1505568-A002

1505568

CRAWN REV

LW

CHECKED

2 1

H

G

F

E

D

C

B z j:::

f= V) z

L,J V)

!a

F

E

D

C

B

A

8 7 6 5 4

~ COVER 48"x 104" PIECE OF PAINTED

WOOD ON EXTERIOR WALL WITH

FIRES TOP VARIOUS INTUMESCENT OR FIRE RETARDANT

PENETRATIONS THROUGH PAINT; PLYWOOD EXTENDS ON BOTH COORDINATE EMERGENCY LIGHTS AND EXIT CEILING, INCLUDING: SIDES OF WALL TO BE DEMOLISHED SIGN WITH NEW FIRE ESCAPE TO BE 4 INSULATED , /I v ADDED UNDER DIFFERENT PROJECT

PIPES AND 1 CABLE----....~~~~· ~~~l;;~~~;j;~~~~fj;;~~;;;~·=========i-~~1~~Q·~~~~ 0 FIRE STOP 5 CONDUITS AND ( ) E:T,,, \_ COVER 12"x 18" PIECE OF PARTIALLY

1 PIPE THROUGH CEILING-~~· PAINTED WOOD ON EXTERIOR WALL WITH

INTUMESCENT PAINT

CUT TO FIT AND INST ALL GYPSUM

BOARD IN LARGE HOLE IN CEILING;

FIRESTOP JOINTS WHERE GYPSUM

IS INSTALLED--------~ •

FIRESTOP INSULATED PIPE

THROUGH CEILING ------........._

I

FIRESTOP 2 CONDUITS

THROUGH CEILING

AROUND COLUMN FIRESTOP

VARIOUS PENETRATIONS

THROUGH CEILING.,, INCLUDING:

1 PIPE AND 1 CONuUIT

~AROUND COLUMN FIRESTOP 3

CONDUITS THROUGH CEILING

COVER EXISTING PIECES OF RANDOM

WOOD ON CEILING CAPPROXIMATEL Y

10 LOCATIONS) WITH INTUMESCENT OR

FIRE RETARD ANT PAINT

AROUND COLUMN FIRESTOP

1 CONDUIT THROUGH CEILING

EFIRESTOP 1 HOLE

THROUGH CEILING

- --------------- CUT TO FIT AND INST ALL GYPSUM

AND 1 PIPE

BOARD IN LARGE HOLE IN CEILING;

FIRESTOP JOINTS WHERE GYPSUM

IS INSTALLED

INSTALL SIGN STATING I t----- COVER EXISTING PIECES OF PAINTED "DOORS TO REMAIN CLOSED WOOD 3"x 84"; 2"x 4"; 12"x 18";

AT ALL TIMES. NO AND 75"x 97" WITH INTUMESCENT

~- FIRESTOP VARIOUS HOLES IN

WALL

STORAGE PERMITTED"--~"'- OR FIRE RETARDANT PAINT ~IRESTOP HOLES THROUGH

"'-~(- WALL ABOVE EXIT SIGN

llli·H-J.?-+,---1--.---~----------_f_--, _,_-,--__ ---...... ~-F'f-~···~~~~9\ REMOVE ABANDONED CABLE

TRAYS; COMPLETE 2-HOUR

FIRE RESISTANCE RATED

WALL CONSTRUCTION ABOVE

DOOR AT CABLE TRAY

PENETRATION (CMU, GYPSUM

OR APPROVED EQUAL) AND

FIRESTOP ALL PENETRATING

ITEMS THROUGH WALL

INCLUDING CABLE TRAYS,

CABLES, CONDUITS, PIPES --t+Ht-'

WIRE

CHASE

CLOSET

( r-

FIRESTOP 1 CONDUIT /

THROUGH WALL------~

\ \ --1--+--1---1 ON ~

-+-+--<l--+--1 up

LFIRESTOP

IN FLOOR

WALL

ELEV.

HOLE AT PIPES

AND AT BASE OF

u

@ THIRD FLOOR PLAN

4' 8'

SCALE: 1/ 4" = 1'-0"

8 7 6

FIRESTOP 2 CONDUITS THROUGH CEILING J

U CUT TO FIT AND INST ALL

GYPSUM BOARD IN LARGE

HOLE IN CEILING; FIRESTOP

JOINTS WHERE GYPSUM

IS INSTALLED

REMOVE EXPANDABLE FOAM FROM

PENETRATION THROUGH CEILING AND

FLOOR AND FIRESTOP CABLES, 1

CONDUIT, AND 1 INSULATED PIPE

THROUGH CEILING

~- FIRESTOP 2 INSULATED PIPES

THROUGH CEILING

FIRESTOP INSULATED PIPE

THROUGH CEILING-------

~- FIRESTOP 5 INSULATED PIPES

THROUGH CEILING

COVER 18"x 24" PIECE OF PARTIALLY

PAINTED WOOD COVERING EXTERIOR

WALL WITH IN TUMESCENT OR FIRE

RETARD ANT PAINT

5 4

2 1

LIFE SAFETY LEGEND

-------------- HEAD-OF-WALL FIRESTOPPING REQUIRED

I EXIT I EXIT SIGN

~ EMERGENCY LIGHT - OUTDOOR UNITS TO BE

WEATHERPROOF AS INDICATED IN SCOPE OF

WORK DOCUMENT

LIFE SAFETY NOTES

1, EXISTING PENETRATIONS NOTED ARE BASED ON VISUAL

OBSERVATIONS DURING SITE SURVEY ONLY,

2, CONTRACTOR SHALL BE RESPONSIBLE FOR SEALING ALL

PENETRATIONS THROUGH ALL FIRE OR SMOKE RESISTANCE

RATED CONSTRUCTION INDICATED ON THIS SHEET WITH A UL

CLASSIFIED THROUGH-PENETRATION FIRE-STOP ASSEMBLY

AND/ OR HEAD-OF-WALL JOINT SYSTEM, WHETHER THE

PENETRATION IS SPECIFICALLY INDICATED OR NOT.

3. NEW PENETRATIONS CREATED BY FIRE ALARM SYSTEM WORK

AND ANY OTHER WORK ASSOCIATED WITH THIS FIRE LIFE

SAFETY UPGRADE MUST ALSO BE SEALED BY THE CONTRACTOR

AS PART OF THIS UPGRADE.

REV APPROVED

DATE DESCRIPTIO~ JCN

DEPARTMENT OF TRANSPORTATION

FEDERAL AVIATION ADMINISTRATION

REDLINE

DATE A=>VD

ATO - TECHNICAL OPERATIONS EASTERN SERVICE AREA

ARSR

FIRE AND LIFE SAFETY MODIFICATIONS

THIRD FLOOR

LIFE SAFETY UPGRADES

BENTON

REVIEWED 3Y SUBM TTED BY

'l-~ },,, y-p~

PA

·-·-··- -· -· __ PROJECT ENGINEER ___ ... --··· -····-·········' M<,f§_: ENGINEERING - \CE ~TE.R. /\_ _ . __

DESIGNED ISSUED BY DATE ' IJCN

r------1--.J.-----i-DR-AW_N ___ _£R~P ENGINEERING SERVICES DRAWING ~0 911312017 15055

R~~

HUGHES 1-----+--+c=Hc=cK=rn~----'Le.c..;w INFRASTRUCTURE QRC- 1505568-A003

2 1

H

G

F

E

D

C

B z j:::

u D::

I- V) z 0 u tr.

LL

w V)

G

F

E

D

C

B

A

INSTALL SIGN STATING

"DOORS TO REMAIN CLOSED

AT ALL TIMES. NO

ii i

7 6 5 4

COORDINATE EMERGENCY LIGHTS AND EXIT

D SIGN WITH NEW FIRE ESCAPE TO BE

ADDED UNDER DIFFERENT PROJECT

[__J

IE:TI

'c:J~

COORDINATE EXIT SIGN WITH NEW FIRE

ESCAPE TO BE ADDED UNDER DIFFERENT

PROJECT

~- COVER EXISTING WOOD 16"x 18" WITH FIRESTOP 2 HOLES

INTUMESCENT OR FIRE RETARDANT PAINT THROUGH FLOOR~/\

V

~- COVER EXISTING PEGBOARD AND EXPOSED

PORTION OF DEMARK WITH INTUMESCENT

OR FIRE RETARDANT PAINT

,,,,,_.,-- COVER EXISTING WOOD 30"x 4" IN

~ TWO PLACES WITH INTUMESCENT

OR FIRE RETARD ANT PAINT

RADAR EQUIPMENT ROOM

----- FIRESTOP LARGE HOLE UNDER BUS

DUCT AND HEAT PIPE THROUGH FLOOR

FIRESTOP 1 CONDUIT

AND 22 CABLES

THROUGH FLOOR-~

~-INST ALL NEW REFRIGATOR; COORDINATE

WITH DEMOLITION UPGRADES DRAWINGS

:1--------------...,,_,-----~,'---------~, 1--------------------------l '-------- ,---------------

Cl 6 ,----1-) INST ALL NEW RESIDENTIAL KITCHEN HOOD

/ SUPPRESSION SYSTEM; SEE SCOPE OF WORK

-~ DOCUMENT FOR MODEL NUMBER; COORDINATE

WITH FIRE ALARM UPGRADES DRAWINGS i<ITCHEN OFFICE

STORAGE PERMITTED" ----Ht-1-1~

FIRESTOP ALL PENETRATING

ITEMS THROUGH WALL

INCLUDING CABLE TRAY; 3

CONDUITS; 2 CABLES; 1 WIRE;

HOLE AT ANGLE IRON; SEAL

WALL JOINTS AT GRATING

ABOVE; PENETRATIONS ON

BOTH SIDES OF THE WALL

FIRESTOP PLASTIC PIPE

THROUGH WALL ____ __.,.-

FIRESTOP AT LEAST 4 HOLES

IN CMU BLOCK WALL

i

I ii

WIRE

CHASE

FIRESTOP CONDUIT THROUGH

WALL/

FIRESTOP JUNCTION BOX;

VARIOUS HOLES AND

2 CONDUITS THROUGH WALL

FIRESTOP VARIOUS HOLES

THROUGH WALL

rs:-----------,, - -

ELEV.

BATH

@FOURTH FLOOR PLAN

0 4' 0 4' 8' iiiiiiiiiiiiiiiiiiiiiiiiiiiiii ~~

SCALE: 1/4" = 1'-0"

6 5

I

L------~

FILES OFFICE

i

2 1

LIFE SAFETY LEGEND

HEAD-OF-WALL FIRESTOPPING REQUIRED

IEXIT I EXIT SIGN

'c:J~

EMERGENCY LIGHT - OUTDOOR UNITS TO BE

WEATHERPROOF AS INDICATED IN SCOPE OF

WORK DOCUMENT

LIFE SAFETY NOTES

1. EXISTING PENETRATIONS NOTED ARE BASED ON VISUAL

OBSERVATIONS DURING SITE SURVEY ONLY.

2, CONTRACTOR SHALL BE RESPONSIBLE FOR SEALING ALL

PENETRATIONS THROUGH ALL FIRE OR SMOKE RESISTANCE

RATED CONSTRUCTION INDICATED ON THIS SHEET WITH A UL

CLASSIFIED THROUGH-PENETRATION FIRE-STOP ASSEMBLY

AND/ OR HEAD-OF-WALL JOINT SYSTEM, WHETHER THE

PENETRATION rs SPECIFICALLY INDICATED OR NOT.

3. NEW PENETRATIONS CREATED BY FIRE ALARM SYSTEM WORK

AND ANY OTHER WORK ASSOCIATED WITH THIS FIRE LIFE

SAFETY UPGRADE MUST ALSO BE SEALED BY THE CONTRACTOR

AS PART OF THIS UPGRADE.

REV APPROVED

DATE DESCRIPTION CCN

DEPARTMENT OF TRANSPORTATION

FEDERAL AVIATION ADMINISTRATION

REDLINE

DATE APVD

ATO - TECHNICAL OPERATIONS EASTERN SERVICE AREA

ARSR

FIRE AND LIFE SAFETY MODIFICATIONS

FOURTH FLOOR

LIFE SAFETY UPGRADES

BENTON

REVIEWED BY SUBMITTED BY APP~EO BY

L -~ r /4 L- 1 -:: LF'~~J-k" 1 0;r

PROJECT ENGINEER , 'MG,,: ENGINEERING - f. N:,JTER A

PA

1 -----7---+--------l=::=::=:-rn __ _JR~P ENGINEr~~~D S~~VICES ;~~iNG ic9/t3/~Ql?JJc~ 15055 R~~

HUGHES CHECKED

I w INFRASTRUCTURE QRC- 1505568-A004

2 1

H

G

F

E

D

C

B z I- Q:'.

I- 1/) z

Q

1/)

F

E

D

C

B

A

1!

INST ALL SIGN STATING "DOORS

TO REMAIN CLOSED AT ALL TIMES.

NO STORAGE PERMITTED"

COMPLETE 2-HOUR FIRE

RESISTANCE RATED WALL

CONSTRUCTION ABOVE DOOR AT

TWO LOCATIONS (CMU, GYPSUM OR

APPROVED EQUAL) AND FIRESTOP

ALL PENETRATING ITEMS THROUGH

WALL INCLUDING MULTIPLE CABLES

AND CONDUITS AT MULTIPLE

HEIGHTS ALONG THE WALL-----...._

r--- "--·

6 5 4

-- COORDINATE EMERGENCY LIGHTS AND EXIT

SIGN WITH NEW FIRE ESCAPE TO BE

ADDED UNDER DIFFERENT PROJECT

I I

EXIT

' L', STORAGE

REMOVE AND RELOCATE COMBUSTIBLE

STORAGE TO FIRST FLOOR STORAGE ROOM;

COORDINATE WITH DEMOLITION UPGRADES

DRAWINGS

r

FIRESTOP AROUND ST AIR STRINGER

BETWEEN FOURTH AND FIFTH

FLOORS INSIDE ST AIR

COVER 20"x 25" PIECE OF

PLYWOOD ON EXTERIOR

WALL WITH INTUMESCENT

OR FIRE RETARDANT PAINT-~

INSTALL 12"x 12" PIECE OF

1/ 4" THICK SHEET MET AL

WHERE EXISTING MASONITE

WAS REMOVED; COORDINATE

WITH DEMOLITION UPGRADES

DRAWINGS

I, ii

~ , _______ ___..,~L. iii I -.-----------, v DN \I\ \, \ \'---

WIRE

CHASE

CLOSET

REMOVE EXISTING

SELF -CLOSING DEVICE

AND INST ALL NEW----

f-r

ELEV. BATH

- - i

PLAN

8'

SCALE: 1/4" ; 1'-0"

5 4

2 1

LIFE SAFETY LEGEND

I EXIT I

J:;::::\;, HEAD-OF-WALL FIRESTOPPING REQUIRED

EXIT SIGN

EMERGENCY LIGHT - OUTDOOR UNITS TO BE

WEATHERPROOF AS INDICATED IN SCOPE OF

WORK DOCUMENT

LIFE SAFETY NOTES

1. EXISTING PENETRATIONS NOTED ARE BASED ON VISUAL

OBSERVATIONS DURING SITE SURVEY ONLY.

2, CONTRACTOR SHALL BE RESPONSIBLE FOR SEALING ALL

PENETRATIONS THROUGH ALL FIRE OR SMOKE RESISTANCE

RATED CONSTRUCTION INDICATED ON THIS SHEET WITH A UL

CLASSIFIED THROUGH-PENETRATION FIRE-STOP ASSEMBLY

AND/ OR HEAD-OF-WALL JOINT SYSTEM, WHETHER THE

PENETRATION IS SPECIFICALLY INDICATED OR NOT •

3. NEW PENETRATIONS CREATED BY FIRE ALARM SYSTEM WORK

AND ANY OTHER WORK ASSOCIATED WITH THIS FIRE LIFE

SAFETY UPGRADE MUST ALSO BE SEALED BY THE CONTRACTOR

AS PART OF THIS UPGRADE.

REV APPROVED

DATE

DESCRIPTION JCN

DEPARTMENT OF TRANSPORTATION

FEDERAL AVIATION ADMINISTRATION

REDLINE

DATE

APVJ

ATO - TECHNICAL OPERATIONS EASTERN SERVICE AREA

ARSR

FIRE AND LIFE SAFETY MODIFICATIONS

FIFTH FLOOR

LIFE SAFETY UPGRADES

BENTON

REVIEWED BY

SUBMIT, ED BY APPROVED BY

<; 0 // a

~ -~~ ,l/l'./2' _-~ ~ (c)7 ' 1 ro, PROJECT ENGINEER , MGR: ENGINEERING - 1CEl\lTER A

PA

H

G

F

E

D

C

B z Ir I-z ii:.

LL

0 w

!a

A

JcSIGNEC ISSUED BY DATE IJCN

,-----"1--+----lbD,'""Aw=N---_JR~P ENGINEERING SERVICES f=cDR~Aw=1N~G -"'~o= 91-"13"--1=20=17'-'-----""15=05=5

R=~ "'1v

HUGHES CHECKED LW INFRASTRUCTURE QRC- 1505568-AOOS

2 1

G

F

E i

D i

C

I B

A

\ FIRESTOP CONDUIT

\ THROUGH WALL

D \J j

UP

5 •

METAL GRATE

WALKING SURFACE

II

I/

L

FIRESTOP HEAD-OF-WALL AT

STRUCTURAL MEMBER

FIRESTOP 2 CONDUITS, PLASTIC

PIPE AND CABLE THROUGH WALL

INSTALL

DAMPER

LOUVER

NEW 20"x 12" FIRE

BEHIND EXISTING

MACH RM.

r--_FIRESTOP HEAD-OF-WALL AT

THREE WALLS INSIDE

ELEV ATOR MACHINE ROOM;

SEAL THREE CONDUIT

PENETRATIONS

/U _________ ...._~==.J

FIRESTOP 2 CONDUITS, CABLES

AND HOLES THROUGH WALL

, 1 \ MEZZANINE PLAN

\P.,OOf) 4' o 4' s·

SCALE: 1/4" ~ 1'-0"

6 5 ii

2 1

LIFE SAFETY LEGEND

HEAD-OF-WALL FIRESTOPPING REQUIRED

I EXIT I EXIT SIGN

~~ EMERGENCY LIGHT - OUTDOOR UNITS TO BE

WEATHERPROOF AS INDICATED IN SCOPE OF

WORK DOCUMENT

LIFE SAFETY NOTES

1. EXISTING PENETRATIONS NOTED ARE BASED ON VISUAL

OBSERVATIONS DURING SITE SURVEY ONLY.

2, CONTRACTOR SHALL BE RESPONSIBLE FOR SEALING ALL

PENETRATIONS THROUGH ALL FIRE OR SMOKE RESISTANCE

RATED CONSTRUCTION !ND!CATED ON THIS SHEET WITH A UL

CLASSIFIED THROUGH-PENETRATION FIRE-STOP ASSEMBLY

AND/ OR HEAD-OF-WALL JOINT SYSTEM, WHETHER THE

PENETRATION IS SPECIFICALLY INDICATED OR NOT.

3. NEW PENETRATIONS CREATED BY FIRE ALARM SYSTEM WORK

AND ANY OTHER WORK ASSOCIATED WITH THIS FIRE LIFE

SAFETY UPGRADE MUST ALSO BE SEALED BY THE CONTRACTOR

AS PART OF THIS UPGRADE.

REV APPROVED

DATE DESCRIPTION JCN

DEPARTMENT OF TRANSPORTATION

FEDERAL AVIATION ADMINISTRATION

REDLINE

DATE APVD

ATO - TECHNICAL OPERATIONS EASTERN SERVICE AREA

ARSR

FIRE AND LIFE SAFETY MODIFICATIONS

MEZZANINE

LIFE SAFETY UPGRADES

BENTON

REVIEWED BY SUBMITTED 8: Ar)O BY •

~ // - , ? ~ r 177, - - • ~,/ I ('.',,, PROJECT ENGINEER _,, M~: ENGINEERING \: C NTER A ---+---+-- ------~---

PA

DESIGNED ISSUED BY DATE !Jet, .-------7-_.j____j_DR-AW_N ___ _!RlEJP ENGINEERING SERVICES DRAWING ~0

911312017 1505568

HUGHES 1-----+--+c=HE=cK=Eo __ __,L=w INFRASTRUCTURE QRC-. 1505568-A006

REV

2 1

H

G

F

E

D

C

B z ~ u I-z 0 u 0 u.

Q l,J

G

F

E

D

C

B

A

Ii ii

FLOOR MOUNTED DOOR HOLD-OPEN DEVICE --

PROGRAM FIRE ALARM SYSTEM TO

RELEASE MAGNETIC DOOR HOLD OPEN

I -

I

OE VICE UPON ANY AL ARM SIGNAL',· CM '-' ~

~ ~\c ~y

~ '--- -~ C

1\, D [\J

! WIRE

\ LOBBY

• CHASE

CLOSET £LE!/.

.,._i..-1--1-up

Ii

1 , FIRST FLOOR PLAN

FOOt 1

4' o 4' s· -

SCALE: 1/4" = 1'-0"

7 6

I

STORAGE

I

GENERATOR

BOILER

'------' >-------------a

I

BOILER

TREATMENT

ROOM

I ii

2 1

FIRE ALARM NOTES

1. EXISTING EST MODEL i0500 FIRE ALARM SYSTEM CONTROL UNIT TO

REMAIN IN PLACE. ALL NEW EQUIPMENT TO BE INSTALLED SHALL BE

CONNECTED TO THE EXISTING SYSTEM. SYSTEM SHALL BE

REPROGRAMMED AS INDICATED IN THE UPGRADES DESIGN PACKAGE.

2. THE AUTOMATIC FIRE ALARM SYSTEM EQUIPMENT SHALL BE INSTALLED

IN ACCORDANCE WITH NFPA 72 AND SECTION 28 31 00 FIRE DETECTION

AND ALARM SYSTEM SPECIFICATION REQUIREMENTS AS OUTLINED IN

THE QRC FLS UPGRADE SCOPE OF WORK DOCUMENT.

3. NEW INITIATING DEVICES AND NOTIFICATION APPLIANCES SHALL BE

INSTALLED IN A PROFESSIONAL, NEAT AND WORKMAN-LIKE MANNER,

ALL CIRCUITS SHALL TEST FREE FROM GROUNDS AND SHORT CIRCUIT

FAULTS.

4. ALL NEW WIRING SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 70.

5. ALL NEW WIRING AS PART OF THIS PROJECT SHALL BE INSTALLED IN

METAL RACEWAY FROM 0 1 TO 8 1 HIGH ON WALLS AND AT ANY OTHER

LOCATION THAT IS SUBJECT TO PHYSICAL DAMAGE, RACEWAY SHALL

BE MIN I MUM 3#4 11 EMT.

6. ALL NEW SIGNALING LINE CIRCUIT (SLC) AND NOTIFICATION APPLIANCE

CIRCUIT (NAC) WIRING SHALL BE WIRED CLASS A,

7. A PHYSICAL SEPARATION (DISTANCE) OF NOT LESS THAN ONE (1) FOOT

ON A VERTICAL PLANE AND NOT LESS THAN FOUR (4l FEET ON A

HORIZONTAL PLAN SHALL BE ACHIEVED FOR ALL CLASS A WIRING.

11 T-TAPPING 11 SHALL NOT BE PERMITTED.

8. EXISTING EQUIPMENT TO BE REMOVED AND/ OR RELOCATED IS NOTED

ON THE DRAWINGS. WHERE EXISTING EQUIPMENT IS TO BE REMOVED,

THE EXISTING EQUIPMENT SHALL BE REMOVED AND THE AREA SHALL BE

PATCHED AND/OR REPAIRED ACCORDINGLY AND IT SHALL MATCH THE

EXISTING WALLS TO THE SATISFACTION OF THE FAA, RESIDENT ENGINEER

(REl AND THE CONTRACTING OFFICER (CO).

9, IF THERE IS A CONFLICT BETWEEN THE REFERENCED NFPA STANDARDS,

FEDERAL, STATE OR LOCAL CODES, AND THE CONTRACT DOCUMENTS, IT

IS THE CONTRACTOR'S RESPONSIBILITY TO IMMEDIATELY BRING THE

CONFLICT TO THE ATTENTION OF THE CO FOR RESOLUTION. NFPA

STANDARDS SHALL SUPERSEDE LOCAL CODES UNLESS LOCAL CODES ARE

MORE STRINGENT. CONTRACTOR SHALL NOT ATTEMPT TO RESOLVE

CONFLICTS DIRECTLY WITH THE LOCAL AUTHORITIES UNLESS

SPECIFICALLY AUTHORIZED BY THE CO (OR DESIGNATED REPRESENTATIVE).

10. NEW ADDRESSABLE MANUAL FIRE ALARM BOXES SHALL BE INSTALLED

SO THE TOP OF THE OPERATING HANDLE IS LOCATED BETWEEN 42 AND 44

INCHES ABOVE THE FINISHED FLOOR, IN ACCORDANCE WITH

SPECIFICATION 28 31 00.

FIRE ALARM LEGEND

ADDRESSABLE SMOKE DETECTOR

ADDRESSABLE MANUAL FIRE ALARM BOX

ADDRESSABLE MONITOR MODULE

ADDRESSABLE CONTROL RELAY OUTPUT MODULE

MAGNETIC DOOR HOLD-OPEN DEVICE

WALL MOUNTED COMBINATION HORN/STROBE NOTIFICATION

APPLIANCE (WITH CANDELA RATING AS NOTED)

REV APPROVED

DATE DcSC'<PTION i

JCN

DEPARTMENT OF TRANSPORTATION

FEDERAL A VIA TI ON ADMINISTRATION

REDLINE

DATE

ATO - TECHNICAL OPERATIONS EASTERN SERVICE

ARSR

FIRE AND LIFE SAFETY MODIFICATIONS

FIRST FLOOR

FIRE ALARM UPGRADES

BENTON

PROJECT ENGINEER MG~: ENGINEERING - C[N~ER A

APVD

AREA

PA

DESIGNED ISSUED BY DATE' IJC~

,-----i--+---l~DR-AW_N::.:_ __ __!R~P ENGINEERING SERVICES DRAWING ~0 911312017 1505568

HUGHES 1---+--+c=H=Ec=Krn~-------'L"-"---lw INFRASTRUCTURE QRC- 1505568-F001

REV

2 1

H

G

F

E

D

C

B z Q I- 0::

I- VJ z

0 u..

t.,J

VJ

ii

G

F

E l

D

C ii

B

A

REMOVE EXISTING SMOKE

DETECTOR; COORDINATE

WITH DEMOLITION

UPGRADES DRAWINGS

I

\ OFFICE ) .

OFFICE

.c;._-COORDINATE MANUAL FIRE

ALARM BOX LOCATION WITH

NEW FIRE ESCAPE TO BE ADDED

UNDER DIFFERENT PROJECT

'---REMOVE EXISTING NOTIFICATION

COORDINATE WITH DEMOLITION UPGRADES

DRAWINGS

REMOVE EXISTING SMOKE DETECTOR

AND RELOCATE TO CEILING ABOVE;

COORDINATE WITH DEMOLITION

APPLIANCES AND RELOCATE AS SHOWN;

UPGRADES DRAWINGS--------'

STORAGE

PROGRAM FIRE ALARM SYSTEM TO

RELEASE MAGNETIC DOOR HOLD OPEN

~j\(~ __ D_E_v_1c_E_U_P_O_N_AN_Y_A_L __ A_R_M_s1_G_N-AL:~

WIRE

CHASE

CLOSET

I

CM

ELEV

FLOOR

4'

SCALE: 1/4" = 1'-0"

6 I

I

LOCKER

ROOM

BATHROOM

PLAN

8'

MECHANICAL / STORAGE

~ 4 i ii ii

I 3

2 1

FIRE ALARM NOTES

1, EXISTING EST MODEL i0500 FIRE ALARM SYSTEM CONTROL UNIT TO

REMAIN IN PLACE. ALL NEW EQUIPMENT TO BE INSTALLED SHALL BE

CONNECTED TO THE EXISTING SYSTEM. SYSTEM SHALL BE

REPROGRAMMED AS INDICATED IN THE UPGRADES DESIGN PACKAGE.

2. THE AUTOMATIC FIRE ALARM SYSTEM EQUIPMENT SHALL BE INSTALLED

IN ACCORDANCE WITH NFPA 72 AND SECTION 28 31 00 FIRE DETECTION

AND ALARM SYSTEM SPECIFICATION REQUIREMENTS AS OUTLINED IN

THE QRC FLS UPGRADE SCOPE OF WORK DOCUMENT .

3, NEW INITIATING DEVICES AND NOTIFICATION APPLIANCES SHALL BE

INSTALLED IN A PROFESSIONAL, NEAT AND WORKMAN-LIKE MANNER .

ALL CIRCUITS SHALL TEST FREE FROM GROUNDS AND SHORT CIRCUIT

FAULTS.

4. ALL NEW WIRING SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 70.

5. ALL NEW WIRING AS PART OF THIS PROJECT SHALL BE INSTALLED IN

METAL RACEWAY FROM O' TO 8' HIGH ON WALLS AND AT ANY OTHER

LOCATION THAT JS SUBJECT TO PHYSICAL DAMAGE. RACEWAY SHALL

BE MINIMUM 3#4" EMT,

6. ALL NEW SIGNALING LINE CIRCUIT (SLCl AND NOTIFICATION APPLIANCE

CIRCUIT (NAC) WIRING SHALL BE WIRED CLASS A.

7, A PHYSICAL SEPARATION (DISTANCE) OF NOT LESS THAN ONE (1 l FOOT

ON A VERTICAL PLANE AND NOT LESS THAN FOUR (4) FEET ON A

HORIZONTAL PLAN SHALL BE ACHIEVED FOR ALL CLASS A WIRING.

"T-TAPPING 11 SHALL NOT BE PERMITTED.

8. EXISTING EQUIPMENT TO BE REMOVED AND/ OR RELOCATED IS NOTED

ON THE DRAWINGS. WHERE EXISTING EQUIPMENT IS TO BE REMOVED,

THE EXISTING EQUIPMENT SHALL BE REMOVED AND THE AREA SHALL BE

PATCHED AND/OR REPAIRED ACCORDINGLY AND IT SHALL MATCH THE

EXISTING WALLS TO THE SATISFACTION OF THE FAA, RESIDENT ENGINEER

(RE) AND THE CONTRACTING OFFICER (CO) .

9. IF THERE IS A CONFLICT BETWEEN THE REFERENCED NFPA STANDARDS,

FEDERAL, STATE OR LOCAL CODES, AND THE CONTRACT DOCUMENTS, IT

IS THE CONTRACTOR'S RESPONSIBILITY TO IMMEDIATELY BRING THE

CONFLICT TO THE ATTENTION OF THE CO FOR RESOLUTION. NFPA

STANDARDS SHALL SUPERSEDE LOCAL CODES UNLESS LOCAL CODES ARE

MORE STRINGENT. CONTRACTOR SHALL NOT ATTEMPT TO RESOLVE

CONFLICTS DIRECTLY WITH THE LOCAL AUTHORITIES UNLESS

SPECIFICALLY AUTHORIZED BY THE CO (OR DESIGNATED REPRESENTATIVE).

10. NEW ADDRESSABLE MANUAL FIRE ALARM BOXES SHALL BE INSTALLED

SO THE TOP OF THE OPERATING HANDLE IS LOCATED BETWEEN 42 AND 44

INCHES ABOVE THE FINISHED FLOOR, IN ACCORDANCE WITH

SPECIFICATION 28 31 00 .

FIRE ALARM LEGEND

CD ADDRESSABLE SMOKE DETECTOR

II] ADDRESSABLE MANUAL FIRE ALARM BOX

jMMI ADDRESSABLE MONITOR MODULE jcMI ADDRESSABLE CONTROL RELAY OUTPUT MODULE

0--1 MAGNETIC DOOR HOLD-OPEN DEVICE

WALL MOUNTED COMBINATION HORN/STROBE NOTIFICATION

APPLIANCE (WITH CANDELA RATING AS NOTED)

REV APPROVED

DATE

DESCRIPTION

JCN

i

DEPARTMENT OF TRANSPORTATION

FEDERAL A VIA TI ON ADMINISTRATION

REDLINE

DATE

ATO - TECHNICAL OPERATIONS EASTERN SERVICE

ARSR

FIRE AND LIFE SAFETY MODIFICATIONS

SECOND FLOOR

FIRE ALARM UPGRADES

BENTON

RC:VIEWED BY SUBMITTEu gy -

" ·y__ - fl _)~ ~Jc_, PROJECT ENGINEER MG MNGINEERING "° ~ NTER A

/>PVD

AREA

PA

DESIGNED

RP

ISSUED BY DATE JCN

ENGINEERING SERVICES DR,\WiNG ~0 911312017

INFRASTRUCTURE QRC- 1505568-F002

1505568

HUGHES

DRAWN

LW

CHECKED

REV

2 1

H

G

F

E

D

C

B z I- :::> er:

I-t/) z ii:.

l,J t/)

G

F

E

D

C

B

A

• WIRE

CHAS£

CLOSET

'----l--1- REMOVE EXISTING SMOKE DETECTOR

INSIDE OFFICE; COORDINATE WITH

DEMOLITION UPGRADES DRAWINGS

I --·-···

PROGRAM FIRE ALARM SYSTEM TO

RELEASE MAGNETIC DOOR HOLD OPEN

DEVICE UPON ANY ALARM SIGNAL

CM

-41---1---1----!-- up

£LEV.

SCALE: 1/ 4" = 1'-0"

5 •

COORDINATE MANUAL FIRE ALARM BOX

LOCATION WITH NEW FIRE ESCAPE TO BE

ADDED UNDER DIFFERENT PROJECT

4 3

II

4 3

2 1

FIRE ALARM NOTES

1. EXISTING EST MODEL i0500 FIRE ALARM SYSTEM CONTROL UNIT TO

REMAIN IN PLACE. ALL NEW EQUIPMENT TO BE INSTALLED SHALL BE

CONNECTED TO THE EXISTING SYSTEM. SYSTEM SHALL BE

REPROGRAMMED AS INDICATED IN THE UPGRADES DESIGN PACKAGE .

2. THE AUTOMATIC FIRE ALARM SYSTEM EQUIPMENT SHALL BE INSTALLED

IN ACCORDANCE WITH NFPA 72 AND SECTION 28 31 00 FIRE DETECTION

AND ALARM SYSTEM SPECIFICATION REQUIREMENTS AS OUTLINED IN

THE QRC FLS UPGRADE SCOPE OF WORK DOCUMENT.

3. NEW INITIATING DEVICES AND NOTIFICATION APPLIANCES SHALL BE

INSTALLED IN A PROFESSIONAL, NEAT AND WORKMAN-LIKE MANNER.

ALL CIRCUITS SHALL TEST FREE FROM GROUNDS AND SHORT CIRCUIT

FAULTS.

4. ALL NEW WIRING SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 70.

5. ALL NEW WIRING AS PART OF THIS PROJECT SHALL BE INSTALLED IN

METAL RACEWAY FROM O' TO 8' HIGH ON WALLS AND AT ANY OTHER

LOCATION THAT IS SUBJECT TO PHYSICAL DAMAGE. RACEWAY SHALL

BE MINIMUM 3#4" EMT.

6. ALL NEW SIGNALING LINE CIRCUIT (SLCl AND NOTIFICATION APPLIANCE

CIRCUIT (NAC) WIRING SHALL BE WIRED CLASS A.

7. A PHYSICAL SEPARATION (DISTANCE) OF NOT LESS THAN ONE (1) FOOT

ON A VERTICAL PLANE AND NOT LESS THAN FOUR (4l FEET ON A

HORIZONTAL PLAN SHALL BE ACHIEVED FOR ALL CLASS A WIRING.

"T-TAPPING" SHALL NOT BE PERMITTED.

8. EXISTING EQUIPMENT TO BE REMOVED AND/ OR RELOCATED IS NOTED

ON THE DRAWINGS. WHERE EXISTING EQUIPMENT IS TO BE REMOVED,

THE EXISTING EQUIPMENT SHALL BE REMOVED AND THE AREA SHALL BE

PATCHED ANO/OR REPAIRED ACCORDINGLY AND IT SHALL MATCH THE

EXISTING WALLS TO THE SATISFACTION OF THE FAA, RESIDENT ENGINEER

(RE) AND THE CONTRACTING OFFICER (CO).

9. IF THERE IS A CONFLICT BETWEEN THE REFERENCED NFPA STANDARDS,

FEDERAL, STATE OR LOCAL CODES, AND THE CONTRACT DOCUMENTS, IT

IS THE CONTRACTOR'S RESPONSIBILITY TO IMMEDIATELY BRING THE

CONFLICT TO THE ATTENTION OF THE CO FOR RESOLUTION. NFPA

STANDARDS SHALL SUPERSEDE LOCAL CODES UNLESS LOCAL CODES ARE

MORE STRINGENT. CONTRACTOR SHALL NOT ATTEMPT TO RESOLVE

CONFLICTS DIRECTLY WITH THE LOCAL AUTHORITIES UNLESS

SPECIFICALLY AUTHORIZED BY THE CO (OR DESIGNATED REPRESENTATIVE).

10. NEW ADDRESSABLE MANUAL FIRE ALARM BOXES SHALL BE INSTALLED

SO THE TOP OF THE OPERATING HANDLE IS LOCATED BETWEEN 42 AND 44

INCHES ABOVE THE FINISHED FLOOR, IN ACCORDANCE WITH

SPECIFICATION 28 31 00 .

FIRE ALARM LEGEND

CD ADDRESSABLE SMOKE DETECTOR

[II ADDRESSABLE MANUAL FIRE ALARM BOX

IMMI ADDRESSABLE MONITOR MODULE

ICMI ADDRESSABLE CONTROL RELAY OUTPUT MODULE

0-j MAGNETIC DOOR HOLD-OPEN DEVICE

WALL MOUNTED COMBINATION HORN/STROBE NOTIFICATION

APPLIANCE (WITH CANDELA RATING AS NOTED)

REV APPROVED

DATE DESCRIPTION • i JCN

DEPARTMENT OF TRANSPORTATION

FEDERAL AVIATION ADMINISTRATION

REDLINE

DA"E

ATO - TECHNICAL OPERATIONS EASTERN SERVICE

ARSR

FIRE AND LIFE SAFETY MODIFICATIONS

THIRD FLOOR

FIRE ALARM UPGRADES

BENTON

REVIEWED BY SUBMITTED BY

PROJECT ENGINEER , M;R: ENGINEERING - CENTER A

APVD

AREA

PA

DESIGNED ISSUED BY DA'(_ IJCN \

,-------t--_J__j_DR-AW_N ___ _jRl!"JP ENGINEERING SERVICES DRAWING ~0 911312017 1505568

HUGHES CHECKED LW INFRASTRUCTURE QRC- 1505568-F003

REV

2 1

H

G

F

E

D

C

B z t;

c::

I- <JI z

IJ..

t.,J

<JI

!11 ii

G

II

ii

F ii

E

D

C

II

B

A

.. ·.~... =j

REMOVE EXISTING HEAT

DETECTOR

KITCHEN

INTERFACE MODULE TO KITCHEN HOOD

SUPPRESSION RELEASING SYSTEM

PROGRAM FIRE ALARM SYSTEM TO

REPORT AS AN ALARM SIGNAL~ ---...~

l£J

RADAR EQUIPMENT ROOM

I r-PROGRAM FIRE ALARM

SYSTEM TO RELEASE

MAGNETIC DOOR HOLD

OPEN DEVICE UPON

ANY ALARM SIGNAL

~-CM

I\ ,, I\

DN ~

w

WIRE

CHA.SE I

CLOSET

(J)

ELEV. ~

w

UP 0..

0..

SCALE: 1/4" = 1'-0"

7 6

5 •

OFFICE

I\ - -

~ ~ L

BATH FILES

4 3

II

I

" i

I I

~loll L- !

OFFICE t

4 3

2 1

FIRE ALARM NOTES

1. EXISTING EST MODEL i0500 FIRE ALARM SYSTEM CONTROL UNIT TO

REMAIN IN PLACE, ALL NEW EQUIPMENT TO BE INSTALLED SHALL BE

CONNECTED TO THE EXISTING SYSTEM. SYSTEM SHALL BE

REPROGRAMMED AS INDICATED IN THE UPGRADES DESIGN PACKAGE,

2, THE AUTOMATIC FIRE ALARM SYSTEM EQUIPMENT SHALL BE INSTALLED

IN ACCORDANCE WITH NFPA 72 AND SECTION 28 31 00 FIRE DETECTION

AND ALARM SYSTEM SPECIFICATION REQUIREMENTS AS OUTLINED IN

THE QRC FLS UPGRADE SCOPE OF WORK DOCUMENT.

3, NEW INITIATING DEVICES AND NOTIFICATION APPLIANCES SHALL BE

INSTALLED IN A PROFESSIONAL, NEAT AND WORKMAN-LIKE MANNER.

ALL CIRCUITS SHALL TEST FREE FROM GROUNDS AND SHORT CIRCUIT

FAULTS.

4. ALL NEW WIRING SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 70.

5. ALL NEW WIRING AS PART OF THIS PROJECT SHALL BE INSTALLED IN

METAL RACEWAY FROM O' TO 8 1 HIGH ON WALLS AND AT ANY OTHER

LOCATION THAT IS SUBJECT TO PHYSICAL DAMAGE. RACEWAY SHALL

BE MINIMUM 3#4" EMT.

6, ALL NEW SIGNALING LINE CIRCUIT (SLC) AND NOTIFICATION APPLIANCE

CIRCUIT <NAC) WIRING SHALL BE WIRED CLASS A.

7. A PHYSICAL SEPARATION (DISTANCE) OF NOT LESS THAN ONE (1) FOOT

ON A VERTICAL PLANE AND NOT LESS THAN FOUR (4) FEET ON A

HORIZONTAL PLAN SHALL BE ACHIEVED FOR ALL CLASS A WIRING.

"T-TAPPING" SHALL NOT BE PERMITTED.

8. EXISTING EQUIPMENT TO BE REMOVED AND/ OR RELOCATED IS NOTED

ON THE DRAWINGS. WHERE EXISTING EQUIPMENT IS TO BE REMOVED,

THE EXISTING EQUIPMENT SHALL BE REMOVED AND THE AREA SHALL BE

PATCHED AND/OR REPAIRED ACCORDINGLY AND IT SHALL MATCH THE

EXISTING WALLS TO THE SATISFACTION OF THE FAA, RESIDENT ENGINEER

(REl AND THE CONTRACTING OFFICER (COl .

9. IF THERE IS A CONFLICT BETWEEN THE REFERENCED NFPA STANDARDS,

FEDERAL, STATE OR LOCAL CODES, AND THE CONTRACT DOCUMENTS, IT

IS THE CONTRACTOR'S RESPONSIBILITY TO IMMEDIATELY BRING THE

CONFLICT TO THE ATTENTION OF THE CO FOR RESOLUTION. NFPA

STANDARDS SHALL SUPERSEDE LOCAL CODES UNLESS LOCAL CODES ARE

MORE STRINGENT. CONTRACTOR SHALL NOT ATTEMPT TO RESOLVE

CONFLICTS DIRECTLY WITH THE LOCAL AUTHORITIES UNLESS

SPECIFICALLY AUTHORIZED BY THE CO (OR DESIGNATED REPRESENTATIVE).

10. NEW ADDRESSABLE MANUAL FIRE ALARM BOXES SHALL BE INSTALLED

SO THE TOP OF THE OPERATING HANDLE IS LOCATED BETWEEN 42 AND 44

INCHES ABOVE THE FINISHED FLOOR, IN ACCORDANCE WITH

SPECIFICATION 28 31 00,

FIRE ALARM LEGEND

[I]

0-1

ADDRESSABLE SMOKE DETECTOR

ADDRESSABLE MANUAL FIRE ALARM BOX

ADDRESSABLE MONITOR MODULE

ADDRESSABLE CONTROL RELAY OUTPUT MODULE

MAGNETIC DOOR HOLD-OPEN DEVICE

WALL MOUNTED COMBINATION HORN/STROBE NOTIFICATION

APPLIANCE (WITH CANDELA RATING AS NOTED)

REV APPROVED

DATE DESCRIPTION JCN

DEPARTMENT OF TRANSPORTATION

FEDERAL AVIATION ADMINISTRATION

REDLINE

DATE

ATO - TECHNICAL OPERATIONS EASTERN SERVICE

ARSR

FIRE AND LIFE SAFETY MODIFICATIONS

FOURTH FLOOR

FIRE ALARM UPGRADES

BENTON

PROJtCT ENGINEER MGR: ENGINEERING - c bNTER A

APVJ

AREA

PA

DESIGNED ISSUED BY DATE 1JCN\

r--------L-L_JLDR-A'I-VN ___ _JR!EjP ENGINEERING SERVICES DRAWING ~0

911312017 1505568

HUGHES CrlEC><D LW INFRASTRUCTURE QRC.;.. 1505568-F004

REV

2 1

H

G

F

E

D

C

B z a:

z

0 u..

0 w ::, G

F

I

E

D

C

B

A i i

7 6

PROGRAM FIRE ALARM SYSTEM TO

RELEASE MAGNETIC DOOR HOLD OPEN

DEVICE UPON ANY ALARM SIGNAL

•~ ~ f---r---------------, i

WIRE

CHASE

CLOSET

DN I\ ,

CM

5 •

~ ~-COORDINATE MANUAL FIRE ALARM BOX

STORAGE

ELEV.

SCALE: 1/ 4" = 1'-0"

LOCATION WITH NEW FIRE ESCAPE TO BE

ADDED UNDER DIFFERENT PROJECT

f.,--

BATH

4 3 i i

4 3

2 1

FIRE ALARM NOTES

1. EXISTING EST MODEL i0500 FIRE ALARM SYSTEM CONTROL UNIT TO

REMAIN IN PLACE. ALL NEW EQUIPMENT TO BE INSTALLED SHALL BE

CONNECTED TO THE EXISTING SYSTEM. SYSTEM SHALL BE

REPROGRAMMED AS INDICATED IN THE UPGRADES DESIGN PACKAGE.

2. THE AUTOMATIC FIRE ALARM SYSTEM EQUIPMENT SHALL BE INSTALLED

IN ACCORDANCE WITH NFPA 72 AND SECTION 28 31 00 FIRE DETECTION

AND ALARM SYSTEM SPECIFICATION REQUIREMENTS AS OUTLINED IN

THE QRC FLS UPGRADE SCOPE OF WORK DOCUMENT.

3. NEW INITIATING DEVICES AND NOTIFICATION APPLIANCES SHALL BE

INSTALLED IN A PROFESSIONAL, NEAT AND WORKMAN-LIKE MANNER.

ALL CIRCUITS SHALL TEST FREE FROM GROUNDS AND SHORT CIRCUIT

FAULTS.

4. ALL NEW WIRING SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 70.

5. ALL NEW WIRING AS PART OF THIS PROJECT SHALL BE INSTALLED IN

METAL RACEWAY FROM O' TO 8 1 HIGH ON WALLS AND AT ANY OTHER

LOCATION THAT IS SUBJECT TO PHYSICAL DAMAGE. RACEWAY SHALL

BE MINIMUM 3#4" EMT.

6. ALL NEW SIGNALING LINE CIRCUIT (SLC) AND NOTIFICATION APPLIANCE

CIRCUIT (NAC) WIRING SHALL BE WIRED CLASS A.

7. A PHYSICAL SEPARATION (DISTANCE) OF NOT LESS THAN ONE (1) FOOT

ON A VERTICAL PLANE AND NOT LESS THAN FOUR (4) FEET ON A

HORIZONTAL PLAN SHALL BE ACHIEVED FOR ALL CLASS A WIRING.

11 T-TAPPING• SHALL NOT BE PERMITTED.

8. EXISTING EQUIPMENT TD BE REMOVED AND/ OR RELOCATED JS NOTED

ON THE DRAWINGS. WHERE EXISTING EQUIPMENT IS TO BE REMOVED,

THE EXISTING EQUIPMENT SHALL BE REMOVED AND THE AREA SHALL BE

PATCHED AND/OR REPAIRED ACCORDINGLY AND IT SHALL MATCH THE

EXISTING WALLS TD THE SATISFACTION OF THE FAA, RESIDENT ENGINEER

CRE) AND THE CONTRACTING OFFICER (CO).

9. IF THERE IS A CONFLICT BETWEEN THE REFERENCED NFPA STANDARDS,

FEDERAL, STATE OR LOCAL CODES, AND THE CONTRACT DOCUMENTS, IT

IS THE CONTRACTOR'S RESPONSIBILITY TO IMMEDIATELY BRING THE

CONFLICT TO THE ATTENTION OF THE CO FOR RESOLUTION. NFPA

STANDARDS SHALL SUPERSEDE LOCAL CODES UNLESS LOCAL CODES ARE

MORE STRINGENT. CONTRACTOR SHALL NOT ATTEMPT TO RESOLVE

CONFLICTS DIRECTLY WITH THE LOCAL AUTHORITIES UNLESS

SPECIFICALLY AUTHORIZED BY THE CO (OR DESIGNATED REPRESENTATIVE).

10. NEW ADDRESSABLE MANUAL FIRE ALARM BOXES SHALL BE INSTALLED

SO THE TOP OF THE OPERATING HANDLE IS LOCATED BETWEEN 42 AND 44

INCHES ABOVE THE FINISHED FLOOR, IN ACCORDANCE WITH

SPECIFICATION 28 31 00 .

FIRE ALARM LEGEND

CD

[I]

@Ml

0-l

ADDRESSABLE SMOKE DETECTOR

ADDRESSABLE MANUAL FIRE ALARM BOX

ADDRESSABLE MONITOR MODULE

ADDRESSABLE CONTROL RELAY OUTPUT MODULE

MAGNETIC DOOR HOLD-OPEN DEVICE

WALL MOUNTED COMBINATION HORN/STROBE NOTIFICATION

APPLIANCE (WITH CANDELA RATING AS NOTED)

I----'-----+------- ----

REV APPROVED

DATE DESCRIPTION JCN

DEPARTMENT OF TRANSPORTATION

FEDERAL A VIA TI ON ADMINISTRATION

REDLINE

CA.TE

ATO - TECHNICAL OPERATIONS EASTERN SERVICE

ARSR

FIRE AND LIFE SAFETY MODIFICATIONS

FIFTH FLOOR

FIRE ALARM UPGRADES

BENTON

APVD

AREA

PA

REVIEWED BY SUBM;TTEO BY APPROVED BY ,

~- ~- tJ - - ' aL- (" ½~~II/ J1/0(

PROJECT ENGINEER 'fi.i ,R: ENGINEERING - CF TER A

DESIGNED ISSUED BY DATE IJCN \

r------7-_4-__j_OR-AW_N ___ _JR~P ENGINEERING SERVICES DRAWING ~;

11312017

HUGHES 1----+---+c~HE=cK=rn~---'L=w INFRASTRUCTURE QRC- 1505568-F005

1505568

RI: V

2 1

H

G

F

E

D

C

B ts u ct:

I-

"' z 0 u ir.

LL

"' !l!

8 7 6 5 4 3

G

I

F

METAL GRATE

WALKING SURFACE

E

D

~- PROGRAM FIRE ALARM SYSTEM TO

/ RELEASE MAGNETIC DOOR HOLD OPEN

1 DEVICE UPON ANY ALARM SIGNAL

__J_ Ctv

C I

D \I

- MACH RM.

UP

B

, 1' MEZZANINE PLAN

\f OOg,i 4' o 4' 8'

SCALE: 1/ 4" = 1'-0"

A

8 7 6 5 • 4 3

2 1

FIRE ALARM NOTES

1. EXISTING EST MODEL i0500 FIRE ALARM SYSTEM CONTROL UNIT TO

REMAIN IN PLACE. ALL NEW EQUIPMENT TO BE INSTALLED SHALL BE

CONNECTED TO THE EXISTING SYSTEM. SYSTEM SHALL BE

REPROGRAMMED AS INDICATED IN THE UPGRADES DESIGN PACKAGE.

2. THE AUTOMATIC FIRE ALARM SYSTEM EQUIPMENT SHALL BE INSTALLED

IN ACCORDANCE WITH NFPA 72 AND SECTION 28 31 00 FIRE DETECTION

AND ALARM SYSTEM SPECIFICATION REQUIREMENTS AS OUTLINED IN

THE QRC FLS UPGRADE SCOPE OF WORK DOCUMENT.

3. NEW INITIATING DEVICES AND NOTIFICATION APPLIANCES SHALL BE

INSTALLED IN A PROFESSIONAL, NEAT AND WORKMAN-LIKE MANNER,

ALL CIRCUITS SHALL TEST FREE FROM GROUNDS AND SHORT CIRCUIT

FAULTS.

4, ALL NEW WIRING SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 70,

5, ALL NEW WIRING AS PART OF THIS PROJECT SHALL BE INSTALLED IN

METAL RACEWAY FROM O' TO 8' HIGH ON WALLS AND AT ANY OTHER

LOCATION THAT IS SUBJECT TO PHYSICAL DAMAGE. RACEWAY SHALL

BE MINIMUM 3#4" EMT.

6. ALL NEW SIGNALING LINE CIRCUIT (SLC) AND NOTIFICATION APPLIANCE

CIRCUIT <NAC) WIRING SHALL BE WIRED CLASS A.

7, A PHYSICAL SEPARATION (DISTANCE) OF NOT LESS THAN ONE (1) FOOT

ON A VERTICAL PLANE AND NOT LESS THAN FOUR (4) FEET ON A

HORIZONTAL PLAN SHALL BE ACHIEVED FOR ALL CLASS A WIRING,

11 T-TAPPING 11 SHALL NOT BE PERMITTED.

8. EXISTING EQUIPMENT TO BE REMOVED AND/ OR RELOCATED IS NOTED

ON THE DRAWINGS. WHERE EXISTING EQUIPMENT IS TO BE REMOVED,

THE EXISTING EQUIPMENT SHALL BE REMOVED AND THE AREA SHALL BE

PATCHED AND/OR REPAIRED ACCORDINGLY AND IT SHALL MATCH THE

EXISTING WALLS TO THE SATISFACTION OF THE FAA, RESIDENT ENGINEER

CREl AND THE CONTRACTING OFFICER (CO) .

9. IF THERE IS A CONFLICT BETWEEN THE REFERENCED NFPA STANDARDS,

FEDERAL, STATE OR LOCAL CODES, AND THE CONTRACT DOCUMENTS, IT

IS THE CONTRACTOR'S RESPONSIBILITY TO IMMEDIATELY BRING THE

CONFLICT TO THE ATTENTION OF THE CO FOR RESOLUTION. NFPA

STANDARDS SHALL SUPERSEDE LOCAL CODES UNLESS LOCAL CODES ARE

MORE STRINGENT. CONTRACTOR SHALL NOT ATTEMPT TO RESOLVE

CONFLICTS DIRECTLY WITH THE LOCAL AUTHORITIES UNLESS

SPECIFICALLY AUTHORIZED BY THE CO (OR DESIGNATED REPRESENTATIVE).

10. NEW ADDRESSABLE MANUAL FIRE ALARM BOXES SHALL BE INSTALLED

SO THE TOP OF THE OPERATING HANDLE IS LOCATED BETWEEN 42 AND 44

INCHES ABOVE THE FINISHED FLOOR, IN ACCORDANCE WITH

SPECIFICATION 28 31 00.

FIRE ALARM LEGEND

(I) ADDRESSABLE SMOKE DETECTOR

[Il ADDRESSABLE MANUAL FIRE ALARM BOX

IMMI ADDRESSABLE MONITOR MODULE

jCMI ADDRESSABLE CONTROL RELAY OUTPUT MODULE

0-l MAGNETIC DOOR HOLD-OPEN DEVICE

WALL MOUNTED COMBINATION HORN/STROBE NOTIFICATION

APPLIANCE (WITH CANDELA RATING AS NOTED)

RE" APPROVED

' DA-:-E )ESCRIPTION JCN

DEPARTMENT OF TRANSPORTATION

FEDERAL A VIA TI ON ADMINISTRATION

RUclNE

DATE

ATO - TECHNICAL OPERATIONS EASTERN SERVICE

ARSR

FIRE AND LIFE SAFETY MODIFICATIONS

MEZZANINE

FIRE ALARM UPGRADES

BENTON

REVIEWED BY SUBMITTED BY APD,OVED BY

.---7 <:. /, • ~ :-? .J.L,_ / g A~ 'f / h, (

PROJECT ENGINEER ' M I_R: ENGINEERING \. ( ~NTER A

APVD

AREA

PA

DESIGNED ISSUED BY DATE IJCN'

,------;__.J___j_DR-AW_N ___ _£R~P ENGINEERING sERv1cEs DRAWING ~0 911312017 15055

R~e

HUGHES CHECKED LW INFRASTRUCTURE QRC- 1505568-F006

2 1

H

G

F

E

D

C

B z i= :;j 0::

I- (J) z ii

IL

L,J :;j (J)

F

E

D

C

B

A j y

WIRE

CHASE

REMOVE EXISTING DOORS AND

FRAMES; REPLACE WITH 90 MINUTE

FIRE RESISTANCE RA TED

SELF-CLOSING, COORDINATED AND

LATCHING DOORS; INCLUDING i

CLOSING AND LATCHING HARDWARE

- REMOVE DROP-DOWN DOOR

HOLDER; PATCH HOLES IN DOORS

AND FRAME; INST ALL NEW

SELF-CLOSING DEVICES AND

COORDINATOR; INST ALL STEEL LOCK

STRIKE; ENSURE DOORS CLOSE

PROPERLY

REMOVE DROP-DOWN DOOR

I >- I

\ > HOLDER; REMOVE EXISTING DOOR

CLOSER; PATCH HOLES IN DOOR ( \,

AND FRAME; INST ALL NEW

SELF-CLOSING DEVICE; INST ALL

STEEL LOCK STRIKE; INST ALL STEEL

BALL BEARING HINGES; ENSURE

DOOR CLOSES PROPERLY

LOBBY

1 FIRST FLOOR

007, SCALE: 1/8"·1'-0"

RADA,'? EQUIPMENT ROOM

r REMOVE DROP-DOWN DOOR HOLDER;

PATCH HOLES IN DOORS AND FRAME;

INST ALL NEW SELF-CLOSING DEVICES

AND COORDINATOR; ADJUST DOOR

CLEARANCES,ENSURE DOORS

CLOSE PROPERLY

II

PLAN

KITCHEN / - INST ALL STEEL LOCK

~ STR~E;ENSURE DOOR

CLOSES PROPERLY~,~

CLOSET i :r' ' I I

ELEV. '-.:J BA TH FIL ES

f+-1-+-+UP i.,J Q Q

STORAGE

I

GENERATOR

BOILER

OFFICE

OFFICE LJ

4 FOURTH FLOOR PLAN

007, SCALE: 1/8"·1'-0"

8 7

6 5

OFFICE _) OFF/Cl .

I I

' I

! rr -

STO.RAG£ M£CHANICAL / STORAGE:

f\ .

-REMOVE DROP-DOWN DOOR ~

HOLDER: PATCH HOLES IN

DOORS AND FRAME; INST ALL

NEW SELF-CLOSING DEVICES

AND COORDINATOR; ADJUST i\ DOOR CLEARANCES;ENSURE C \, DOORS CLOSE PROPERLY LOCK£R ~ 1HVAC UNIT irv 11' I:: :l I u II I ! I I I WIRE u ~.!,._-l._.;,.4- I

CHASF II

.u rr CLOS£T u J u I I l I I I J I l

DI \

I

!UP

i

L

ROOM '

4 r~

BATHROOM

REMOVE DROP DOWN DOOR -

HOLDER; PATCH HOLES IN DOOR

AND FRAME; INST ALL STEEL LOCK

STRIKE; ADJUST DOOR CLEARANCES;

ENSURE DOOR CLOSES PROPERLY

2 SECOND FLOOR PLAN

007, SCALE: 1/8"=1'-0"

~ REMOVE AND REPLACE

DAMAGED DOOR; INST ALL

NEW SELF -CLOSING DEVICES

AND COORDINATOR; ENSURE

DOORS CLOSE PROPERLY

WIRE

CHASE

CLOSET

STORAGE

rlNST ALL STEEL LOCK STRIKE;

ADJUST CLEARANCES;ENSURE

DOOR CLOSES PROPERLY

5 FIFTH FLOOR PLAN

001 SCALE: 1/8"=1'-0"

6 5

I r I

I I

4 3

~ REMOVE DROP-DOWN DOOR

HOLDER; PATCH HOLES IN DOORS

AND FRAME; INST ALL NEW

SELF -CLOSING DEVICES AND

COORDINATOR; ADJUST DOOR

CLEARANCES;ENSURE DOORS

PATCH HOLES IN DOOR AND

FRAME, INST ALL STEEL LOCK ~I

STRIKE; ADJUST DOOR CLEARANCES; j_ll

ENSURE DOOR CLOSES PROPERLY j !1

CLOSE PROPERLY

IV7f+l ________ ,'"' ~~ mr::====;;i

WIRE

CHASE

CLOSET

\ 1¥

3 THIRD FLOOR PLAN

007, SCALE: 1/8"=1'-0"

REMOVE DROP-DOWN

HOLDER: PATCH HOLES IN

DOOR AND FRAME; INST ALL

STEEL LOCK STRIKE; ADJUST

CLEARANCES;ENSURE DOOR

CLOSES PROPERLY-----.._..___

METAL GRATE

WALKiNG SURFACE

INST ALL NEW SELF-CLOSING

DEVICE; PATCH HOLES IN DOOR

AND FRAME; INST ALL STEEL LOCK

STRIKE; ENSURE DOOR CLOSES

PROPERLY

t I

I Ii I

I I I I i I

2 1

DEMOLITION NOTES

1. ALL DEMOLITION WORK SHALL BE CONDUCTED IN

ACCORDANCE WITH THE UPGRADES DESIGN PACKAGE .

2. DEMOLITION WORK SHALL BE COORDINATED WITH THE

LIFE SAFETY UPGRADES AND THE FIRE ALARM SYSTEM

UPGRADES.

3. CONTRACTOR SHALL REMOVE ALL MATERIALS IDENTIFIED

IN THE DEMOLITION UPGRADES AND DISPOSE OF

MATERIALS OFF-SITE IN ACCORDANCE WITH FEDERAL,

STATE, AND LOCAL LAWS.

I---+-----+------------~~-----------·----------------- -- ----

H

G

F

E

D

C

I I

REV APPROVED

)ATE DESCRIPTION JCN REDLINE

DATE APVD B

K+1UN

MACH RM.

6 MEZZANINE

007, SCALE: 1/8"=1'-0"

PLAN

8' 0 -------- 8'

' I ir

I j

16'

ATO

DEPARTMENT OF TRANSPORTATION

FEDERAL AVIATION ADMINISTRATION

- TECHNICAL OPERATIONS EASTERN SERVICE

ARSR

FIRE AND LIFE SAFETY MODIFICATIONS

FIRE DOOR UPGRADES

BENTON

REVIEWED BY SUBMITTED BY APPROVED BY

AREA

PA

SCALE: 1/8 11 = 1'-0" PR JECT ENGINEER

DESIGNED ISSUED BY DATE JCN

,------1---1--+D-RA_VI_N ___ ___tR(E.JP ENGINEERING SERVICES ""oRc-cAcccw,"'NG,....N~Oo9=1~13=1~2=0~17~---=15=0=55cR~""-I~

HUGHES CrECKED LW INFRASTRUCTURE QRC- 1505568-F007

3 2 1 z Q I-iE I- (I) z t,.

C uJ (I)

qrc-1505568-g003
qrc-1505568-d008
qrc-1505568-a001
qrc-1505568-a002
qrc-1505568-a003
qrc-1505568-a004
qrc-1505568-a005
qrc-1505568-a006
qrc-1505568-f001
qrc-1505568-f002
qrc-1505568-f003
qrc-1505568-f004
qrc-1505568-f005
qrc-1505568-f006
qrc-1505568-f007