This file is a miscellaneous calculations worksheet related to construction cost estimation for the Veterans Drive Contract 2 Improvements project on Route 30. The document appears to contain detailed mathematical computations and cost breakdowns used to support the overall project budget and pricing analysis. The calculations likely encompass various cost categories such as labor, materials, equipment, and contingencies necessary for the highway improvement work being solicited under solicitation number 693C73-27-R-000012. As a supporting calculation document rather than a primary contract requirement specification, it functions as a reference tool for contractors and the contracting agency to understand the basis for estimated costs and pricing terms associated with this Federal Highway Administration project administered by the Department of Transportation.

View the file

Other files

Show all 14

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Page

STRUCTURES DESIGN

FINAL CALCULATIONS

VETERANS DRIVE IMPROVEMENTS

STATION 198+36.26 TO STATION 236+68.54

FEDERAL PROJECT ID

DCP-34(1)

PREPARED FOR

UNITED STATES VIRGIN ISLANDS

DEPARTMENT OF PUBLIC WORKS

PREPARED BY

WSP USA

5411 SKYCENTER DRIVE

SUITE 650

TAMPA, FL 33607

APPROVED BY: SCOTT R. LAWSON P.E. NO. 1295-E

MARCH 2024

Contents

WALL STRUCTURES DESIGN CRITERIA

Site Conditions

Geotechnical Conditions

Hydraulic Conditions

WALL LOADS

Dead Load (DC)

Live Loads (LS)

Horizontal Earth (HV) and Vertical Earth Pressure (EV)

Seismic Loads

Water Loads (WA)

Scour

WALL DESIGN PROCEDURE

Sliding

Eccentricity

Bearing Capacity

Load Combinations and Load Factors

Resistance Factors

WALL SEGMENT DESIGN

TYPE 0 SEGMENT

TYPE 1 SEGMENT

TYPE 2 SEGMENT

TYPE 3 SEGMENT

TYPE 4 SEGMENT

TYPE 5 SEGMENT

TYPE 6 SEGMENT

WALL SEGMENT REINFORCEMENT

BOX CULVERT CD2 EXTENSION

BOX CULVERT CD3 EXTENSION

TYPE A AND B LIGHT POLES

SIGNAL MASTARMS

WALL STRUCTURES DESIGN CRITERIA

Site Conditions The seawall retains fill for roadway widening and new waterfront parks from station 198+36.26 to 236+68.54. Portions of the wall will be placed in front of an existing tied sheet pile wall. The existing sheet pile wall was originally constructed in 1954. The PGL of the new roadway varies from 3.94’ to 6.49’ above the MLLW.

Geotechnical Conditions The soils at the site are grouped into four stratums: Fill, Soft Clay and Silt, Alluvium and Bedrock. Soils that have the potential for liquefaction during a seismic event will be removed and replaced with new fill as specified in the geotechnical report.

Hydraulic Conditions Static and Dynamic wave loads as shown in the coastal Engineering report are used in the design of the wall. The permitted footprint of the wall does not allow for the addition of toe protection. Since there is no toe protection the wall is designed for the maximum scour depth as calculated in the hydraulic report.

WALL LOADS

Dead Load (DC) Reinforced Concrete 150 lb/ft3

Live Loads (LS) Live loads will be applied to the wall as a surcharge.

HL-93 Live 250 lb/ft3

Horizontal Earth (HV) and Vertical Earth Pressure (EV) The lateral earth pressures for PMB walls are defined in AASHTO 3.11.5.9.

Moist Unit Weight 125 lb/ft3

Saturated Unit Weight 65.5 = (129.5-64) lb/ft3

Rankine theory is used to calculate Ka and Kp. (AASHTO C3.11.5.9-1 and 3.11.5.3). The benefit of passive soil loads in front of the wall are ignored.

ܽܭ = (2/ߔ-45)ଶ݊ܽݐ

ܭ = (2/ߔ+45)ଶ݊ܽݐ

Seismic Loads As per AASHTO 11.5.4.2 Seismic design is not mandatory for walls in seismic zones 1 through 3, or for walls at sites where the site adjusted peak ground acceleration, AS is less than or equal to 0.4g, unless there is potential for liquefaction induced lateral spreading or if the wall supports another structure which is required to be designed for seismic loading. AASHTO A11.2 states that walls designed using the static method typically do not experience significant damage in locations where the site adjusted peak ground acceleration is below 0.5g.

The site adjusted peak ground acceleration, AS =0.36g.

Seismic design of the wall is not required.

Water Loads (WA) Static water pressure 64 lb/ft3

Buoyancy 64 lb/ft3

In the coastal engineering report, the dynamic water pressures have been calculated for the 100 years storm event. The dynamic pressures are not used since they are offset by passive soil loads behind the wall.

Location

Wave Crest Wave Trough Dynamic Pressure

At Top of Wall (lb/Ft2)

Dynamic Pressure At Mudline

(lb/Ft2)

Wave Trough Elevation

(Ft)

Dynamic Pressure At Mudline

(lb/Ft2) Sta. 198+50 922 876 -6.1 443 Sta. 200+40 911 858 -7.5 545 Sta. 202+40 913 861 -7.0 511 Sta. 204+40 915 864 -7.0 511 Sta. 206+40 915 864 -7.0 511 Sta. 208+40 1018 955 -6.6 477 Sta. 210+40 1025 967 -6.1 443 Sta. 212+30 990 937 -5.6 409 Sta. 213+00 1024 965 -6.1 443 Sta. 214+10 1010 943 -7.5 545 Sta. 216+15 1012 945 -7.5 545 Sta. 218+15 1010 943 -7.5 545 Sta. 220+10 1016 952 -7.0 511 Sta. 222+00 1024 965 -6.1 443 Sta. 223+00 1012 959 -6.1 443 Sta. 224+70 1025 980 -4.7 340 Sta. 225+50 852 822 -2.8 204 Sta. 226+20 831 803 -2.8 204 Sta. 227+80 1055 1008 -3.7 272 Sta. 228+50 1055 1008 -4.7 340 Sta. 229+00 1144 1083 -6.1 443 Sta. 229+50 1144 1083 -5.4 392 Sta. 231+00 831 803 -2.8 204 Sta. 232+30 1144 1083 -5.9 426 Sta. 232+90 1144 1083 -6.3 460 Sta. 233+20 1144 1083 -4.9 358 Sta. 234+20 1055 1008 -3.3 238 Sta. 235+20 873 841 -2.3 170 Sta. 236+70 703 682 -1.4 102

Scour In the coastal engineering report, the scour elevations have been calculated for the 100 years storm event. The scour elevations will be used for all load cases.

Location Mudline Elevation (Ft, MMLW)

Scour Depth (Ft)

Scour Elevation (Ft, MMLW)

Sta. 198+50 -13.0 6.0 -19.0 Sta. 200+40 -16.0 4.8 -20.8 Sta. 202+40 -15.0 4.7 -19.7 Sta. 204+40 -15.0 4.7 -19.7 Sta. 206+40 -15.0 4.6 -19.6 Sta. 208+40 -14.0 6.7 -20.7 Sta. 210+40 -13.0 8.4 -21.4 Sta. 212+30 -12.0 8.4 -20.4 Sta. 213+00 -13.0 8.4 -21.4 Sta. 214+10 -16.0 6.7 -22.7 Sta. 216+15 -16.0 6.7 -22.7 Sta. 218+15 -16.0 6.7 -22.7 Sta. 220+10 -15.0 6.7 -21.7 Sta. 222+00 -13.0 5.4 -18.4 Sta. 223+00 -7.0 4.7 -11.7 Sta. 224+70 -10.0 5.1 -15.1 Sta. 225+50 -6.0 4.7 -10.7 Sta. 226+20 -6.0 11.7 -17.7 Sta. 227+80 -8.0 7.5 -15.5 Sta. 228+50 -10.0 7.7 -17.7 Sta. 229+00 -13.0 6.5 -19.5 Sta. 229+50 -11.5 9.2 -20.7 Sta. 231+00 -6.0 5.5 -11.5 Sta. 232+30 -12.5 8.0 -20.5 Sta. 232+90 -13.5 6.1 -19.6 Sta. 233+20 -10.5 5.8 -16.3 Sta. 234+20 -7.0 8.5 -15.5 Sta. 235+20 -5.0 7.3 -12.3 Sta. 236+70 -3.0 3.8 -6.8

WALL DESIGN PROCEDURE

The following checks are made for the tallest of each wall type.

Sliding Sliding is checked (AASHTO 10.6.3.4) between the base block and the gravel or concrete leveling pad, and between each block layer.

ܴோ = ܴ߮ோ = ߮ఛܴఛ + ܴ߮

ܴோ = ݈ܽ݊݅݉݊ ݈݃݊݅݀݅ݏ ݁ܿ݊ܽݐݏ݅ݏ݁ݎ ݐݏ݊݅ܽ݃ܽ ݁ݎݑ݈݂݅ܽ ݕܾ ݈݃݊݅݀݅ݏ

߮ఛ = ݁ܿ݊ܽݐݏ݅ݏ݁ݎ ݎݐ݂ܿܽ ݎ݂ ݎℎ݁ܽݏ ݁ܿ݊ܽݐݏ݅ݏ݁ݎ ݊݁݁ݓݐܾ݁ ݈݅ݏ ܽ݊݀ ݊݅ݐܽ݀݊ݑ݂

ܴఛ = ݈ܽ݊݅݉݊ ݈݃݊݅݀݅ݏ ݁ܿ݊ܽݐݏ݅ݏ݁ݎ ݊݁݁ݓݐܾ݁ ݈݅ݏ ܽ݊݀ ݊݅ݐܽ݀݊ݑ݂

߮ = ݁ܿ݊ܽݐݏ݅ݏ݁ݎ ݎݐ݂ܿܽ ݎ݂ ݁ݒ݅ݏݏܽ ݁ܿ݊ܽݐݏ݅ݏ݁ݎ

ܴ = ݈ܽ݊݅݉݊ ݁ܿ݅ݏݏܽ ݁ܿ݊ܽݐݏ݅ݏ݁ݎ ݂ ݈݅ݏ

Eccentricity Eccentricity Limits (AASHTO 11.6.3.3) for block on the gravel leveling pad are e/L<0.33, for block on rock or concrete leveling pad e/L<0.45. The eccentricity limit for block on block is treated the same as block on rock.

ܮ ܯ∑) (ܯ∑−

݁ = ݕݐ݅ܿ݅ݎݐ݊݁ܿܿ݁

ܯ = ݉ݑݏ ݂ ݃݊݅ݐݏ݅ݏ݁ݎ ݏݐ݊݁݉݉

ܯ = ݉ݑݏ ݂ ݃݊݅݊ݎݑݐݎ݁ݒ ݏݐ݊݁݉݉

ܸ = ݉ݑݏ ݂ ݈ܽܿ݅ݐݎ݁ݒ ݏ݁ܿݎ݂

Bearing Capacity Vertical stress (AASHTO 11.6.3.2) shall be used to check bearing resistance. The calculated ultimate bearing capacity is shown in the geotechnical report.

௩ߪ =

ܤ − 2݁

௩ߪ = ݈ܽܿ݅ݐݎ݁ݒ ݈݅ݏ ݏݏ݁ݎݐݏ ݅݊ ݈݅ݏ

ܤ = ݈݈ܽݓ ݁ݏܾܽ ℎݐ݀݅ݓ

Load Combinations and Load Factors AASHTO Table 3.4.1-1 and 3.4.1-2

Load Factors

Strength I (Maximum)

Strength I (Minimum)

Extreme I (Maximum)

Extreme I (Minimum) Service

DL 1.25 0.90 1.25 0.90 1.00

LL surcharge Mooring 1.75 0 1.00

EH

Active 1.50 0.90 1.50 0.90 1.00

EH

At Rest 1.35 0.90 1.35 0.90 1.00

EV 1.35 1.00 1.35 1.00 1.00

WA

(Static) 1.00

WA

(Dynamic) 0 1.00 0

Resistance Factors AASHTO Table 10.5.5.2.2-1

Resistance Factors Strength I

Bearing Resistance 0.45

Precast Concrete to Stone 0.90

Stone to Soil 0.90

Passive

EP 0.50

WALL SEGMENT DESIGN

Made by SRL

Project St Thomas Veterans Drive Date 5/30/2023

Subject Wall Segment Design Check - Summary Checked by RS/SWL

Date 9/25/2023

Filename = C:\Users\Lawsons\Desktop\Wall CADD Files\Veterans Drive St Thomas\Calculations\[Counterfort Wall Design and Bearing Resistance_RS_9-25-23.xlsx]Summary

Segment ∑MResisting ∑MOverturning

Factor of

Safety

Foundation

Width/3

(Ft) e

(Ft) Check ∑Fhorizontal

(Lb)

∑Fvertical

(Lb)

RR = CV tan φf

(Lb)

Check σV

(Lb/SqFt) CDR Bearing B' (ft)

Factored

Bearing

Resistance

(psf)

Check

TYPE 0 52287 13171 4.0 2.67 0.76 OK 2615 12069 6787 OK 1862 1.34 6.5 2487.0 OK

TYPE 1 105410 29132 3.6 3.33 0.78 OK 4270 18066 10160 OK 2139 2.32 8.4 4973.0 OK

TYPE 2 176042 52985 3.3 4.00 0.85 OK 5850 23887 13433 OK 2318 2.44 10.3 5665.0 OK

TYPE 3 273691 121537 2.3 4.67 2.01 OK 9429 30511 17159 OK 3059 1.85 10.0 5665.0 OK

TYPE 4 403808 176015 2.3 5.33 2.00 OK 11508 37938 21335 OK 3159 1.79 12.0 5665.0 OK

TYPE 5 568741 246899 2.3 6.00 2.03 OK 13837 46154 25956 OK 3309 1.71 13.9 5665.0 OK

TYPE 6 778772 336664 2.3 6.67 1.99 OK 16416 55198 31042 OK 3446 1.64 16.0 5665.0 OK

Segment ∑MResisting ∑MOverturning

Factor of

Safety

Foundation

Width/3

(Ft) e

(Ft) Check ∑Fhorizontal

(Lb)

∑Fvertical

(Lb)

RR = CV tan φf

(Lb)

Check σV

(Lb/SqFt) CDR Bearing B' (ft)

Factored

Bearing

Resistance

(psf)

Check

TYPE 0 46172 11556 4.0 2.67 0.67 OK 2259 10381 5838 OK 1557 2.40 6.7 3730.0 OK

TYPE 1 84737 23844 3.6 3.33 0.73 OK 3205 14255 8017 OK 1668 2.98 8.5 4973.0 OK

TYPE 2 141585 43802 3.2 4.00 0.78 OK 4301 18721 10529 OK 1792 3.16 10.4 5665.0 OK

TYPE 3 220492 106859 2.1 4.67 2.22 OK 7297 23783 13375 OK 2489 2.28 9.6 5665.0 OK

TYPE 4 325924 153944 2.1 5.33 2.16 OK 8693 29437 16555 OK 2519 2.25 11.7 5665.0 OK

TYPE 5 459671 215233 2.1 6.00 2.15 OK 10239 35675 20063 OK 2603 2.18 13.7 5665.0 OK

TYPE 6 631025 292904 2.2 6.67 2.05 OK 11935 42527 23916 OK 2674 2.12 15.9 5665.0 OK

Segment ∑MResisting ∑MOverturning

Factor of

Safety

Foundation

Width/3

(Ft) e

(Ft) Check ∑Fhorizontal

(Lb)

∑Fvertical

(Lb)

RR = CV tan φf

(Lb)

Check σV

(Lb/SqFt) CDR Bearing B' (ft)

Factored

Bearing

Resistance

(psf)

Check

TYPE 0 54165 23132 2.3 2.67 1.99 OK 5443 12634 7105 OK 2572 1.18 4.9 3046.0 OK

TYPE 1 110108 49207 2.2 3.33 1.87 OK 8829 19429 10927 OK 3099 1.20 6.3 3730.0 OK

TYPE 2 184165 87095 2.1 4.00 2.31 OK 12486 26295 14788 OK 3561 1.22 7.4 4351.0 OK

TYPE 3 285860 140523 2.0 4.67 2.75 OK 16737 34204 19236 OK 4025 1.24 8.5 4973.0 OK

TYPE 4 419594 212145 2.0 5.33 3.19 OK 21584 43156 24270 OK 4489 1.23 9.6 5532.0 OK

TYPE 5 582071 300777 1.9 6.00 3.59 OK 25833 51988 29237 OK 4804 1.18 10.8 5665.0 OK

TYPE 6 687481 387350 1.8 6.67 4.41 OK 27767 53663 30179 OK 4797 1.18 11.2 5665.0 OK

Segment ∑MResisting ∑MOverturning

Factor of

Safety

Foundation

Width/3

(Ft) e

(Ft) Check

∑Fhorizontal

(Lb)

∑Fvertical

(Lb)

RR = CV tan φf

(Lb)

Check σV

(Lb/SqFt) CDR Bearing B' (ft)

Factored

Bearing

Resistance

(psf)

Check

TYPE 0 47372 21263 2.2 2.67 1.58 OK 5031 10795 6071 OK 2232 1.11 4.8 2487.0 OK

TYPE 1 87387 43079 2.0 3.33 2.10 OK 7643 15261 8583 OK 2628 1.18 5.8 3108.0 OK

TYPE 2 145319 76066 1.9 4.00 2.62 OK 10740 20499 11528 OK 3034 1.23 6.8 3730.0 OK

TYPE 3 224648 122509 1.8 4.67 3.15 OK 14323 26510 14909 OK 3440 1.26 7.7 4351.0 OK

TYPE 4 224648 122509 1.8 4.67 3.15 OK 14323 26510 14909 OK 3847 1.29 8.7 4973.0 OK

TYPE 5 328765 184691 1.8 5.33 3.67 OK 18391 33292 18723 OK 4119 1.34 9.7 5532.0 OK

TYPE 6 456706 262593 1.7 6.67 4.49 OK 25473 47275 26587 OK 4288 1.32 11.0 5665.0 OK

Factored Bearing Resistance Values are hard entered from Nominal Bearing Resistances tab. Lookups are for the values of effective footing width B' rounded down to the nearest whole distance. This is conservative.

* The factored bearing resistance for this row is specifically calculated on the nominal bearing resistance tab, as the rounded down approach does not check.

DESIGN SUMMARY - STORM EVENT (Extreme 1min)

DESIGN SUMMARY - STORM EVENT (Extreme 1max)

DESIGN SUMMARY - NORMAL TIDE (Strength 1min)

DESIGN SUMMARY - NORMAL TIDE (Strength 1max)

COMPUTATION SHEET

TYPE 0 SEGMENT

Project St Thomas Veterans Drive Date 5/30/2023

Subject Wall Segment Design Check - Normal Tide - Strenght 1 max Checked by RS/SWL

Date 9/25/2023

Filename = C:\Users\Lawsons\Desktop\Wall CADD Files\Veterans Drive St Thomas\Calculations\[Counterfort Wall Design and Bearing Resistance_RS_9-25-23.xlsx]Summary

COMPUTATION SHEET

Item Side Load Load

Factor γ

(pcf)

Ka φf=34° h

(Ft)

Volume

(CuFt)

Horizontal

Load

(Lb)

Factored

(Lb)

Vertical

Loads

(Lb)

Factored

(Lb)

Moment Arm

(Ft)

MResisting

(Ft Lb)

MOverturning

(Ft Lb)

Water Passive WA 1.00 64 5 800 800 1.67 1333

Water Active WA 1.00 64 5 800 800 1.67 1333

Wall Coping DC 1.25 150 8.25 1238 1547 1.99 3078

Wall Dry DC 1.25 150 3.21 482 602 1.90 1144

Wall Submerged DC 1.25 86 14.51 1248 1560 3.46 5397

LL on Wall LS 1.75 250 7 1750 3062.5 4.50 13781

LL Active LS 1.75 250 0.28 10 2.83 707 1237 5.00 6184

Mooring LL 1.75

Soil on Wall Dry EV 1.35 110 25.79 2837 3830 5.29 20260

Soil on Wall Submerged EV 1.35 50 21.74 1087 1467 4.97 7293

Active Soil Dry EH 1.50 110 0.28 5 3.53 389 583 6.67 3887

Active Soil Submerged EH 1.50 50 0.28 5 7.07 353 530 2.50 1325

Active Soil Submerged EH 1.50 50 0.28 5 3.53 177 265 1.67 442

Height (Ft) 10.00 2615 12069 52287 13171

Toe (Ft) 1.00 tan φf 0.625 ∑FHorizontal ∑FVertical ∑MResisting ∑MOverturning

Heal (Ft) 7.00 C 0.9 RR = CV tan φf 6787

Foundation (Ft) 8.00 Foundation/3 2.67 σV 1862 e 0.76 b' 6.5

TYPE 0 SEGMENT - NORMAL TIDE

Project St Thomas Veterans Drive Date 5/30/2023

Subject Wall Segment Design Check - Normal Tide - Strength 1 min Checked by RS/SWL

Date 9/25/2023

Filename = C:\Users\Lawsons\Desktop\Wall CADD Files\Veterans Drive St Thomas\Calculations\[Counterfort Wall Design and Bearing Resistance_RS_9-25-23.xlsx]Summary

COMPUTATION SHEET

Item Side Load Load

Factor γ

(pcf)

Ka φf=34° h

(Ft)

Volume

(CuFt)

Horizontal

Load

(Lb)

Factored

(Lb)

Vertical

Loads

(Lb)

Factored

(Lb)

Moment Arm

(Ft)

MResisting

(Ft Lb)

MOverturning

(Ft Lb)

Water Passive WA 1.00 64 5 800 800 1.67 1333

Water Active WA 1.00 64 5 800 800 1.67 1333

Wall Coping DC 0.90 150 8.25 1238 1114 1.99 2216

Wall Dry DC 0.90 150 3.21 482 434 1.90 824

Wall Submerged DC 0.90 86 14.51 1248 1123 3.46 3886

LL on Wall LS 1.75 250 7 1750 3062.5 4.50 13781

LL Active LS 1.75 250 0.28 10 2.83 707 1237 5.00 6184

Mooring LL 1.75

Soil on Wall Dry EV 1.00 125 25.79 3224 3224 5.29 17054

Soil on Wall Submerged EV 1.00 65.5 21.74 1424 1424 4.97 7077

Active Soil Dry EH 0.90 125 0.28 5 3.53 442 398 6.67 2650

Active Soil Submerged EH 0.90 65.5 0.28 5 7.07 463 417 2.50 1042

Active Soil Submerged EH 0.90 65.5 0.28 5 3.53 231 208 1.67 347

Height (Ft) 10.00 2259 10381 46172 11556

Toe (Ft) 1.00 tan φf 0.625 ∑FHorizontal ∑FVertical ∑MResisting ∑MOverturning

Heal (Ft) 7.00 C 0.9 RR = CV tan φf 5838

Foundation (Ft) 8.00 Foundation/3 2.67 σV 1557 e 0.67 b' 6.7

TYPE 0 SEGMENT - NORMAL TIDE

1.90

.0

.6

DC 150 pcf

3.21

DC 150 pcf

21.74

EV 65.5 pcf

14.51

DC 86 pcf

TYPE 0 SEGMENT - NORMAL TIDE

3.46

1.99

.0

.0

5.29

4.97

4.50

7.00

8.00

.0

.0

WA 64 pcf

.6

WA 64 pcf 5 .0

0 6 .6

.5

125 pcf ka

EH

65.5 pcf ka

EH

65.5 pcf ka

EH

250 psf ka

LS

.6

LS 250 psf

1.75

7.001.00

25.79

EV 125 pcf

Project St Thomas Veterans Drive Date 5/30/2023

Subject Wall Segment Design Check - Storm Event - Extreme 1 max Checked by RS/SWL

Date 9/25/2023

Filename = C:\Users\Lawsons\Desktop\Wall CADD Files\Veterans Drive St Thomas\Calculations\[Counterfort Wall Design and Bearing Resistance_RS_9-25-23.xlsx]Summary

COMPUTATION SHEET

Item Side Load Load

Factor γ

(pcf)

Ka φf=34° h

(Ft)

Volume

(CuFt)

Horizontal

Load

(Lb)

Factored

(Lb)

Vertical

Loads

(Lb)

Factored

(Lb)

Moment Arm

(Ft)

MResisting

(Ft Lb)

MOverturning

(Ft Lb)

Water Passive WA 1.00 64 4 512 512 1.33 683

Water Active WA 1.00 64 10 3200 3200 3.33 10667

Wall Coping DC 1.25 150 8.25 1238 1547 1.99 3078

Wall Dry DC 1.25 150 4.36 654 818 1.96 1603

Wall Submerged DC 1.25 86 13.36 1149 1436 3.57 5127

LL on Wall LS 1.75 250 7 1750 3062.5 4.5 13781

LL Active LS 1.75 250 0.28 10 2.83 707 1237 5 6184

Mooring 1.75

Soil on Wall Dry EV 1.35 110 31.64 3480 4698 5.23 24573

Soil on Wall Submerged EV 1.35 50 15.89 795 1073 4.96 5320

Active Soil Dry EH 1.50 110 0.28 6 5.09 560 840 6.00 5038

Active Soil Submerged EH 1.50 50 0.28 4 6.78 339 509 2.00 1018

Active Soil Submerged EH 1.50 50 0.28 4 2.26 113 170 1.33 226

Height (Ft) 10.00 5443 12634 54165 23132

Toe (Ft) 1.00 tan φf 0.625 ∑FHorizontal ∑FVertical ∑MResisting ∑MOverturning

Heal (Ft) 7.00 C 0.9 RR = CV tan φf 7105

Foundation (Ft) 8.00 Foundation/3 2.67 σV 2572 e 1.54 b' 4.9

TYPE 0 SEGMENT - STORM EVENT

Project St Thomas Veterans Drive Date 5/30/2023

Subject Wall Segment Design Check - Storm Event - Extreme 1 min Checked by RS/SWL

Date 9/25/2023

Filename = C:\Users\Lawsons\Desktop\Wall CADD Files\Veterans Drive St Thomas\Calculations\[Counterfort Wall Design and Bearing Resistance_RS_9-25-23.xlsx]Summary

COMPUTATION SHEET

Item Side Load Load

Factor γ

(pcf)

Ka φf=34° h

(Ft)

Volume

(CuFt)

Horizontal

Load

(Lb)

Factored

(Lb)

Vertical

Loads

(Lb)

Factored

(Lb)

Moment Arm

(Ft)

MResisting

(Ft Lb)

MOverturning

(Ft Lb)

Water Passive WA 1.00 64 4 512 512 1.33 683

Water Active WA 1.00 64 10 3200 3200 3.33 10667

Wall Coping DC 0.90 150 8.25 1238 1114 1.99 2216

Wall Dry DC 0.90 150 4.36 654 589 1.96 1154

Wall Submerged DC 0.90 86 13.36 1149 1034 3.57 3691

LL on Wall LS 1.75 250 7 1750 3062.5 4.5 13781

LL Active LS 1.75 250 0.28 10 2.83 707 1237 5 6184

Mooring 1.75

Soil on Wall Dry EV 1.00 125 31.64 3955 3955 5.23 20684

Soil on Wall Submerged EV 1.00 65.5 15.89 1041 1041 4.96 5163

Active Soil Dry EH 0.90 125 0.28 6 5.09 636 572 6.00 3435

Active Soil Submerged EH 0.90 65.5 0.28 4 6.78 444 400 2.00 800

Active Soil Submerged EH 0.90 65.5 0.28 4 2.26 148 133 1.33 178

Height (Ft) 10.00 5031 10795 47372 21263

Toe (Ft) 1.00 tan φf 0.625 ∑FHorizontal ∑FVertical ∑MResisting ∑MOverturning

Heal (Ft) 7.00 C 0.9 RR = CV tan φf 6071

Foundation (Ft) 8.00 Foundation/3 2.67 σV 2232 e 1.58 b' 4.8

TYPE 0 SEGMENT - STORM EVENT

13.36

DC 86 pcf

1.96

.0

.0

.3

4.36

DC 150 pcf

15.89

EV 65.5 pcf

DC 150 pcf

WA 64 pcf 250 psf ka

LS

TYPE 0 SEGMENT - STORM EVENT

3.57

1.99

.0

.0

5.23

4.96

4.50

7.00

8.00

7.001.00

.0

.0

.0

.0

125 pcf ka

EH

65.5 pcf ka

EH

65.5 pcf ka

EH

.3

.3

WA 64 pcf

LS 250 psf

21.8°

31.64

TYPE 1 SEGMENT

Project St Thomas Veterans Drive Date 5/30/2023

Subject Wall Segment Design Check - Normal Tide - Strenght 1 max Checked by RS/SWL

Date 9/25/2023

Filename = C:\Users\Lawsons\Desktop\Wall CADD Files\Veterans Drive St Thomas\Calculations\[Counterfort Wall Design and Bearing Resistance_RS_9-25-23.xlsx]Summary

COMPUTATION SHEET

Item Side Load Load

Factor γ

(pcf)

Ka φf=34° h

(Ft)

Volume

(CuFt)

Horizontal

Load

(Lb)

Factored

(Lb)

Vertical

Loads

(Lb)

Factored

(Lb)

Moment Arm

(Ft)

MResisting

(Ft Lb)

MOverturning

(Ft Lb)

Water Passive WA 1.00 64 8 2048 2048 2.67 5461

Water Active WA 1.00 64 8 2048 2048 2.67 5461

Wall Coping DC 1.25 150 8.25 1238 1547 2.49 3852

Wall Dry DC 1.25 150 3.21 482 602 2.40 1446

Wall Submerged DC 1.25 86 21.01 1807 2259 4.16 9396

LL on Wall LS 1.75 250 8.5 2125 3718.75 5.75 21383

LL Active LS 1.75 250 0.28 13 3.68 919 1608 6.50 10451

Mooring LL 1.75

Soil on Wall Dry EV 1.35 125 33.29 4161 5618 6.57 36908

Soil on Wall Submerged EV 1.35 65.5 48.87 3201 4321 6.24 26965

Active Soil Dry EH 1.50 125 0.28 5 3.53 442 663 9.67 6405

Active Soil Submerged EH 1.50 65.5 0.28 8 11.31 741 1111 4.00 4444

Active Soil Submerged EH 1.50 65.5 0.28 8 9.05 593 889 2.67 2370

Height (Ft) 13.00 4270 18066 105410 29132

Toe (Ft) 1.50 tan φf 0.625 ∑FHorizontal ∑FVertical ∑MResisting ∑MOverturning

Heal (Ft) 8.50 C 0.9 RR = CV tan φf 10160

Foundation (Ft) 10.00 Foundation/3 3.33 σV 2139 e 0.78 b' 8.4

TYPE 1 SEGMENT - NORMAL TIDE

Project St Thomas Veterans Drive Date 5/30/2023

Subject Wall Segment Design Check - Normal Tide - Strength 1 min Checked by RS/SWL

Date 9/25/2023

Filename = C:\Users\Lawsons\Desktop\Wall CADD Files\Veterans Drive St Thomas\Calculations\[Counterfort Wall Design and Bearing Resistance_RS_9-25-23.xlsx]Summary

COMPUTATION SHEET

Item Side Load Load

Factor γ

(pcf)

Ka φf=34° h

(Ft)

Volume

(CuFt)

Horizontal

Load

(Lb)

Factored

(Lb)

Vertical

Loads

(Lb)

Factored

(Lb)

Moment Arm

(Ft)

MResisting

(Ft Lb)

MOverturning

(Ft Lb)

Water Passive WA 1.00 64 8 2048 2048 2.67 5461

Water Active WA 1.00 64 8 2048 2048 2.67 5461

Wall Coping DC 0.90 150 8.25 1238 1114 2.49 2773

Wall Dry DC 0.90 150 3.21 482 434 2.40 1041

Wall Submerged DC 0.90 86 21.01 1807 1626 4.16 6765

LL on Wall LS 1.75 250 8.5 2125 3718.75 5.75 21383

LL Active LS 1.75 250 0.28 13 3.68 919 1608 6.50 10451

Mooring LL 1.75

Soil on Wall Dry EV 1.00 125 33.29 4161 4161 6.57 27339

Soil on Wall Submerged EV 1.00 65.5 48.87 3201 3201 6.24 19974

Active Soil Dry EH 0.90 125 0.28 5 3.53 442 398 9.67 3843

Active Soil Submerged EH 0.90 65.5 0.28 8 11.31 741 667 4.00 2666

Active Soil Submerged EH 0.90 65.5 0.28 8 9.05 593 533 2.67 1422

Height (Ft) 13.00 3205 14255 84737 23844

Toe (Ft) 1.50 tan φf 0.625 ∑FHorizontal ∑FVertical ∑MResisting ∑MOverturning

Heal (Ft) 8.50 C 0.9 RR = CV tan φf 8017

Foundation (Ft) 10.00 Foundation/3 3.33 σV 1668 e 0.73 b' 8.5

TYPE 1 SEGMENT - NORMAL TIDE

2.40

DC 150 pcf

3.21

DC 150 pcf

21.01

DC 86 pcf

48.87

EV 65.5 pcf

TYPE 1 SEGMENT - NORMAL TIDE

4.16

2.49

.0

.0

.0

6.57

6.24

5.75

8.50

10.00

8.501.50

.0

.0

.6

WA 64 pcf

LS 250 psf

.5

.6

.6

.0

125 pcf ka

EH

65.5 pcf ka

EH

65.5 pcf ka

EH

WA 64 pcf

250 psf ka

LS

.6

.0

33.29

Project St Thomas Veterans Drive Date 5/30/2023

Subject Wall Segment Design Check - Storm Event - Extreme 1 max Checked by RS/SWL

Date 9/25/2023

Filename = C:\Users\Lawsons\Desktop\Wall CADD Files\Veterans Drive St Thomas\Calculations\[Counterfort Wall Design and Bearing Resistance_RS_9-25-23.xlsx]Summary

COMPUTATION SHEET

Item Side Load Load

Factor γ

(pcf)

Ka φf=34° h

(Ft)

Volume

(CuFt)

Horizontal

Load

(Lb)

Factored

(Lb)

Vertical

Loads

(Lb)

Factored

(Lb)

Moment Arm

(Ft)

MResisting

(Ft Lb)

MOverturning

(Ft Lb)

Water Passive WA 1.00 64 6 1152 1152 2.00 2304

Water Active WA 1.00 64 13 5408 5408 4.33 23435

Wall Coping DC 1.25 150 8.25 1238 1547 2.49 3852

Wall Dry DC 1.25 150 5.55 832 1040 2.51 2611

Wall Submerged DC 1.25 86 18.67 1606 2007 4.35 8731

LL on Wall LS 1.75 250 8.5 2125 3718.75 5.75 21383

LL Active LS 1.75 250 0.28 13 3.68 919 1608 6.5 10451

Mooring 1.75

Soil on Wall Dry EV 1.35 125 47.95 5994 8092 6.47 52354

Soil on Wall Submerged EV 1.35 65.5 34.20 2240 3024 6.24 18872

Active Soil Dry EH 1.50 125 0.28 7 6.93 866 1299 8.33 10822

Active Soil Submerged EH 1.50 65.5 0.28 6 11.87 778 1167 3.00 3500

Active Soil Submerged EH 1.50 65.5 0.28 6 5.09 333 500 2.00 1000

Height (Ft) 13.00 8829 19429 110108 49207

Toe (Ft) 1.50 tan φf 0.625 ∑FHorizontal ∑FVertical ∑MResisting ∑MOverturning

Heal (Ft) 8.50 C 0.9 RR = CV tan φf 10927

Foundation (Ft) 10.00 Foundation/3 3.33 σV 3099 e 1.87 b' 6.3

TYPE 1 SEGMENT - STORM EVENT

Project St Thomas Veterans Drive Date 5/30/2023

Subject Wall Segment Design Check - Storm Event - Extreme 1 min Checked by RS/SWL

Date 9/25/2023

Filename = C:\Users\Lawsons\Desktop\Wall CADD Files\Veterans Drive St Thomas\Calculations\[Counterfort Wall Design and Bearing Resistance_RS_9-25-23.xlsx]Summary

COMPUTATION SHEET

Item Side Load Load

Factor γ

(pcf)

Ka φf=34° h

(Ft)

Volume

(CuFt)

Horizontal

Load

(Lb)

Factored

(Lb)

Vertical

Loads

(Lb)

Factored

(Lb)

Moment Arm

(Ft)

MResisting

(Ft Lb)

MOverturning

(Ft Lb)

Water Passive WA 1.00 64 6 1152 1152 2.00 2304

Water Active WA 1.00 64 13 5408 5408 4.33 23435

Wall Coping DC 0.90 150 8.25 1238 1114 2.49 2773

Wall Dry DC 0.90 150 5.55 832 749 2.51 1880

Wall Submerged DC 0.90 86 18.67 1606 1445 4.35 6287

LL on Wall LS 1.75 250 8.5 2125 3718.75 5.75 21383

LL Active LS 1.75 250 0.28 13 3.68 919 1608 6.5 10451

Mooring 1.75

Soil on Wall Dry EV 1.00 125 47.95 5994 5994 6.47 38781

Soil on Wall Submerged EV 1.00 65.5 34.20 2240 2240 6.24 13980

Active Soil Dry EH 0.90 125 0.28 7 6.93 866 779 8.33 6493

Active Soil Submerged EH 0.90 65.5 0.28 6 11.87 778 700 3.00 2100

Active Soil Submerged EH 0.90 65.5 0.28 6 5.09 333 300 2.00 600

Height (Ft) 13.00 7643 15261 87387 43079

Toe (Ft) 1.50 tan φf 0.625 ∑FHorizontal ∑FVertical ∑MResisting ∑MOverturning

Heal (Ft) 8.50 C 0.9 RR = CV tan φf 8583

Foundation (Ft) 10.00 Foundation/3 3.33 σV 2628 e 2.10 b' 5.8

TYPE 1 SEGMENT - STORM EVENT

2.51

5.55

DC 150 pcf

18.67

DC 86 pcf

34.20

EV 65.5 pcf

TYPE 1 SEGMENT - STORM EVENT

4.35

2.49

.0

.0

.0

6.47

6.24

5.75

8.50

10.00

8.501.50

.0

.0

.5

.0

.3

.3

.0

125 pcf ka

EH

65.5 pcf ka

EH

65.5 pcf ka

EH

WA 64 pcf250 psf ka

LS

.0

.0

WA 64 pcf

LS 250 psf

22.93°

47.95

TYPE 2 SEGMENT

Project St Thomas Veterans Drive Date 5/30/2023

Subject Wall Segment Design Check - Normal Tide - Strenght 1 max Checked by RS/SWL

Date 9/25/2023

Filename = C:\Users\Lawsons\Desktop\Wall CADD Files\Veterans Drive St Thomas\Calculations\[Counterfort Wall Design and Bearing Resistance_RS_9-25-23.xlsx]Summary

COMPUTATION SHEET

Item Side Load Load

Factor γ

(pcf)

Ka φf=34° h

(Ft)

Volume

(CuFt)

Horizontal

Load

(Lb)

Factored

(Lb)

Vertical

Loads

(Lb)

Factored

(Lb)

Moment Arm

(Ft)

MResisting

(Ft Lb)

MOverturning

(Ft Lb)

Water Passive WA 1.00 64 11 3872 3872 3.67 14197

Water Active WA 1.00 64 11 3872 3872 3.67 14197

Wall Coping DC 1.25 150 8.25 1238 1547 2.99 4625

Wall Dry DC 1.25 150 3.21 482 602 2.90 1747

Wall Submerged DC 1.25 86 27.86 2396 2995 4.90 14675

LL on Wall LS 1.75 250 10 2500 4375 7.00 30625

LL Active LS 1.75 250 0.28 16 4.52 1131 1979 8.00 15831

Mooring LL 1.75

Soil on Wall Dry EV 1.35 125 40.79 5099 6883 7.84 53965

Soil on Wall Submerged EV 1.35 65.5 84.64 5544 7484 7.51 56207

Active Soil Dry EH 1.50 125 0.28 5 3.53 442 663 12.67 8393

Active Soil Submerged EH 1.50 65.5 0.28 11 15.55 1018 1528 5.50 8402

Active Soil Submerged EH 1.50 65.5 0.28 11 17.10 1120 1680 3.67 6161

Height (Ft) 16.00 5850 23887 176042 52985

Toe (Ft) 2.00 tan φf 0.625 ∑FHorizontal ∑FVertical ∑MResisting ∑MOverturning

Heal (Ft) 10.00 C 0.9 RR = CV tan φf 13433

Foundation (Ft) 12.00 Foundation/3 4.00 σV 2318 e 0.85 b' 10.3

TYPE 2 SEGMENT - NORMAL TIDE

Project St Thomas Veterans Drive Date 5/30/2023

Subject Wall Segment Design Check - Normal Tide - Strength 1 min Checked by RS/SWL

Date 9/25/2023

Filename = C:\Users\Lawsons\Desktop\Wall CADD Files\Veterans Drive St Thomas\Calculations\[Counterfort Wall Design and Bearing Resistance_RS_9-25-23.xlsx]Summary

COMPUTATION SHEET

Item Side Load Load

Factor γ

(pcf)

Ka φf=34° h

(Ft)

Volume

(CuFt)

Horizontal

Load

(Lb)

Factored

(Lb)

Vertical

Loads

(Lb)

Factored

(Lb)

Moment Arm

(Ft)

MResisting

(Ft Lb)

MOverturning

(Ft Lb)

Water Passive WA 1.00 64 11 3872 3872 3.67 14197

Water Active WA 1.00 64 11 3872 3872 3.67 14197

Wall Coping DC 0.90 150 8.25 1238 1114 2.99 3330

Wall Dry DC 0.90 150 3.21 482 434 2.90 1258

Wall Submerged DC 0.90 86 27.86 2396 2156 4.90 10566

LL on Wall LS 1.75 250 10 2500 4375 7.00 30625

LL Active LS 1.75 250 0.28 16 4.52 1131 1979 8.00 15831

Mooring LL 1.75

Soil on Wall Dry EV 1.00 125 40.79 5099 5099 7.84 39974

Soil on Wall Submerged EV 1.00 65.5 84.64 5544 5544 7.51 41635

Active Soil Dry EH 0.90 125 0.28 5 3.53 442 398 12.67 5036

Active Soil Submerged EH 0.90 65.5 0.28 11 15.55 1018 917 5.50 5041

Active Soil Submerged EH 0.90 65.5 0.28 11 17.10 1120 1008 3.67 3697

Height (Ft) 16.00 4301 18721 141585 43802

Toe (Ft) 2.00 tan φf 0.625 ∑FHorizontal ∑FVertical ∑MResisting ∑MOverturning

Heal (Ft) 10.00 C 0.9 RR = CV tan φf 10529

Foundation (Ft) 12.00 Foundation/3 4.00 σV 1792 e 0.78 b' 10.4

TYPE 2 SEGMENT - NORMAL TIDE

2.90

3.21

DC 150 pcf

84.64

EV 65.5 pcf

27.86

DC 86 pcf

4.90

2.99

.0

.0

7.84

7.51

7.00

10.00

12.00

2.00 10.00

.6

WA 64 pcf

.0

.0

2.75

LS 250 psf

TYPE 2 SEGMENT - NORMAL TIDE

.0

.6

.6

.5

125 pcf ka

EH

65.5 pcf ka

EH

65.5 pcf ka

EH

WA 64 pcf

250 psf ka

LS

.6

.0

40.79

Project St Thomas Veterans Drive Date 5/30/2023

Subject Wall Segment Design Check - Storm Event - Extreme 1 max Checked by RS/SWL

Date 9/25/2023

Filename = C:\Users\Lawsons\Desktop\Wall CADD Files\Veterans Drive St Thomas\Calculations\[Counterfort Wall Design and Bearing Resistance_RS_9-25-23.xlsx]Summary

COMPUTATION SHEET

Item Side Load Load

Factor γ

(pcf)

Ka φf=34° h

(Ft)

Volume

(CuFt)

Horizontal

Load

(Lb)

Factored

(Lb)

Vertical

Loads

(Lb)

Factored

(Lb)

Moment Arm

(Ft)

MResisting

(Ft Lb)

MOverturning

(Ft Lb)

Water Passive WA 1.00 64 8 2048 2048 2.67 5461

Water Active WA 1.00 64 16 8192 8192 5.33 43691

Wall Coping DC 1.25 150 8.25 1238 1547 2.99 4625

Wall Dry DC 1.25 150 6.78 1016 1270 3.06 3887

Wall Submerged DC 1.25 86 24.30 2089 2612 5.15 13450

LL on Wall LS 1.75 250 10 2500 4375 7.00 30625

LL Active LS 1.75 250 0.28 16 4.52 1131 1979 8.00 15831

Mooring 1.75

Soil on Wall Dry EV 1.35 125 67.23 8403 11344 7.71 87464

Soil on Wall Submerged EV 1.35 65.5 58.20 3812 5147 7.51 38652

Active Soil Dry EH 1.50 125 0.28 8 9.05 1131 1696 10.67 18093

Active Soil Submerged EH 1.50 65.5 0.28 8 18.09 1185 1778 4.00 7110

Active Soil Submerged EH 1.50 65.5 0.28 8 9.05 593 889 2.67 2370

Height (Ft) 16.00 12486 26295 184165 87095

Toe (Ft) 2.00 tan φf 0.625 ∑FHorizontal ∑FVertical ∑MResisting ∑MOverturning

Heal (Ft) 10.00 C 0.9 RR = CV tan φf 14788

Foundation (Ft) 12.00 Foundation/3 4.00 σV 3561 e 2.31 b' 7.4

TYPE 2 SEGMENT - STORM EVENT

Project St Thomas Veterans Drive Date 5/30/2023

Subject Wall Segment Design Check - Storm Event - Extreme 1 min Checked by RS/SWL

Date 9/25/2023

Filename = C:\Users\Lawsons\Desktop\Wall CADD Files\Veterans Drive St Thomas\Calculations\[Counterfort Wall Design and Bearing Resistance_RS_9-25-23.xlsx]Summary

COMPUTATION SHEET

Item Side Load Load

Factor γ

(pcf)

Ka φf=34° h

(Ft)

Volume

(CuFt)

Horizontal

Load

(Lb)

Factored

(Lb)

Vertical

Loads

(Lb)

Factored

(Lb)

Moment Arm

(Ft)

MResisting

(Ft Lb)

MOverturning

(Ft Lb)

Water Passive WA 1.00 64 8 2048 2048 2.67 5461

Water Active WA 1.00 64 16 8192 8192 5.33 43691

Wall Coping DC 0.90 150 8.25 1238 1114 2.99 3330

Wall Dry DC 0.90 150 6.78 1016 915 3.06 2799

Wall Submerged DC 0.90 86 24.30 2089 1880 5.15 9684

LL on Wall LS 1.75 250 10 2500 4375 7.00 30625

LL Active LS 1.75 250 0.28 16 4.52 1131 1979 8.00 15831

Mooring 1.75

Soil on Wall Dry EV 1.00 125 67.23 8403 8403 7.71 64788

Soil on Wall Submerged EV 1.00 65.5 58.20 3812 3812 7.51 28631

Active Soil Dry EH 0.90 125 0.28 8 9.05 1131 1018 10.67 10856

Active Soil Submerged EH 0.90 65.5 0.28 8 18.09 1185 1067 4.00 4266

Active Soil Submerged EH 0.90 65.5 0.28 8 9.05 593 533 2.67 1422

Height (Ft) 16.00 10740 20499 145319 76066

Toe (Ft) 2.00 tan φf 0.625 ∑FHorizontal ∑FVertical ∑MResisting ∑MOverturning

Heal (Ft) 10.00 C 0.9 RR = CV tan φf 11528

Foundation (Ft) 12.00 Foundation/3 4.00 σV 3034 e 2.62 b' 6.8

TYPE 2 SEGMENT - STORM EVENT

3.06

6.77

DC 150 pcf

58.20

EV 65.5 pcf

24.30

DC 86 pcf

5.15

2.99

.0

.0

7.71

7.51

7.00

10.00

12.00

2.00 10.00

.6

WA 64 pcf

.0

.0

.0

.0

.3

.6

.0

125 pcf ka

EH

65.5 pcf ka

EH

65.5 pcf ka

EH

WA 64 pcf

250 psf ka

LS

.6

2.75

LS 250 psf

TYPE 2 SEGMENT - STORM EVENT

23.63°

67.22

TYPE 3 SEGMENT

Project St Thomas Veterans Drive Date 5/30/2023

Subject Wall Segment Design Check - Normal Tide - Strenght 1 max Checked by RS/SWL

Date 9/25/2023

Filename = C:\Users\Lawsons\Desktop\Wall CADD Files\Veterans Drive St Thomas\Calculations\[Counterfort Wall Design and Bearing Resistance_RS_9-25-23.xlsx]Summary

COMPUTATION SHEET

Item Side Load Load

Factor γ

(pcf)

Ka φf=34° h

(Ft)

Volume

(CuFt)

Horizontal

Load

(Lb)

Factored

(Lb)

Vertical

Loads

(Lb)

Factored

(Lb)

Moment Arm

(Ft)

MResisting

(Ft Lb)

MOverturning

(Ft Lb)

Water Passive WA 1.00 64 14 6272 6272 4.67 29269

Water Active WA 1.00 64 14 6272 6272 4.67 29269

Wall Coping DC 1.25 150 8.25 1238 1547 3.49 5399

Wall Dry DC 1.25 150 3.21 482 602 3.40 2048

Wall Submerged DC 1.25 86 35.06 3015 3769 5.60 21106

LL on Wall LS 1.75 250 11.5 2875 5031.25 8.25 41508

LL Active LS 1.75 250 0.28 19 5.37 1343 2350 9.50 22324

Mooring LL 1.75 1000 1750 19.00 33250

Soil on Wall Dry EV 1.35 125 48.29 6036 8149 9.10 74155

Soil on Wall Submerged EV 1.35 65.5 129.07 8454 11413 8.78 100206

Active Soil Dry EH 1.50 125 0.28 5 3.53 442 663 15.67 10380

Active Soil Submerged EH 1.50 65.5 0.28 14 19.79 1296 1944 7.00 13610

Active Soil Submerged EH 1.50 65.5 0.28 14 27.70 1815 2722 4.67 12703

Height (Ft) 19.00 9429 30511 273691 121537

Toe (Ft) 2.50 tan φf 0.625 ∑FHorizontal ∑FVertical ∑MResisting ∑MOverturning

Heal (Ft) 11.50 C 0.9 RR = CV tan φf 17159

Foundation (Ft) 14.00 Foundation/3 4.67 σV 3059 e 2.01 b' 10.0

TYPE 3 SEGMENT - NORMAL TIDE

Project St Thomas Veterans Drive Date 5/30/2023

Subject Wall Segment Design Check - Normal Tide - Strength 1 min Checked by RS/SWL

Date 9/25/2023

Filename = C:\Users\Lawsons\Desktop\Wall CADD Files\Veterans Drive St Thomas\Calculations\[Counterfort Wall Design and Bearing Resistance_RS_9-25-23.xlsx]Summary

COMPUTATION SHEET

Item Side Load Load

Factor γ

(pcf)

Ka φf=34° h

(Ft)

Volume

(CuFt)

Horizontal

Load

(Lb)

Factored

(Lb)

Vertical

Loads

(Lb)

Factored

(Lb)

Moment Arm

(Ft)

MResisting

(Ft Lb)

MOverturning

(Ft Lb)

Water Passive WA 1.00 64 14 6272 6272 4.67 29269

Water Active WA 1.00 64 14 6272 6272 4.67 29269

Wall Coping DC 0.90 150 8.25 1238 1114 3.49 3887

Wall Dry DC 0.90 150 3.21 482 434 3.40 1475

Wall Submerged DC 0.90 86 35.06 3015 2714 5.60 15196

LL on Wall LS 1.75 250 11.5 2875 5031.25 8.25 41508

LL Active LS 1.75 250 0.28 19 5.37 1343 2350 9.50 22324

Mooring LL 1.75 1000 1750 19.00 33250

Soil on Wall Dry EV 1.00 125 48.29 6036 6036 9.10 54930

Soil on Wall Submerged EV 1.00 65.5 129.07 8454 8454 8.78 74227

Active Soil Dry EH 0.90 125 0.28 5 3.53 442 398 15.67 6228

Active Soil Submerged EH 0.90 65.5 0.28 14 19.79 1296 1167 7.00 8166

Active Soil Submerged EH 0.90 65.5 0.28 14 27.70 1815 1633 4.67 7622

Height (Ft) 19.00 7297 23783 220492 106859

Toe (Ft) 2.50 tan φf 0.625 ∑FHorizontal ∑FVertical ∑MResisting ∑MOverturning

Heal (Ft) 11.50 C 0.9 RR = CV tan φf 13375

Foundation (Ft) 14.00 Foundation/3 4.67 σV 2489 e 2.22 b' 9.6

TYPE 3 SEGMENT - NORMAL TIDE

5.66

3.21

DC 150 pcf

35.06

DC 86 pcf

3.49

.0

.0

9.10

8.78

8.25

11.50

3.40

2.50 11.50

14.00

.0

.0

.6

WA 64 pcf

.5

.0

.6

.6

.0

125 pcf ka

EH

65.5 pcf ka

EH

65.5 pcf ka

EH

WA 64 pcf

250 psf ka

LS

.6

LS 250 psf

129.07

EV 65.5 pcf

3.25

TYPE 3 SEGMENT - NORMAL TIDE

48.29

Project St Thomas Veterans Drive Date 5/30/2023

Subject Wall Segment Design Check - Storm Event - Extreme 1 max Checked by RS/SWL

Date 9/25/2023

Filename = C:\Users\Lawsons\Desktop\Wall CADD Files\Veterans Drive St Thomas\Calculations\[Counterfort Wall Design and Bearing Resistance_RS_9-25-23.xlsx]Summary

COMPUTATION SHEET

Item Side Load Load

Factor γ

(pcf)

Ka φf=34° h

(Ft)

Volume

(CuFt)

Horizontal

Load

(Lb)

Factored

(Lb)

Vertical

Loads

(Lb)

Factored

(Lb)

Moment Arm

(Ft)

MResisting

(Ft Lb)

MOverturning

(Ft Lb)

Water Passive WA 1.00 64 10 3200 3200 3.33 10667

Water Active WA 1.00 64 19 11552 11552 6.33 73163

Wall Coping DC 1.25 150 8.25 1238 1547 3.49 5399

Wall Dry DC 1.25 150 8.04 1206 1508 3.62 5457

Wall Submerged DC 1.25 86 30.23 2600 3250 5.97 19401

LL on Wall LS 1.75 250 11.5 2875 5031.25 8.25 41508

LL Active LS 1.75 250 0.28 19 5.37 1343 2350 9.5 22324

Mooring 1.75

Soil on Wall Dry EV 1.35 125 89.46 11182 15096 8.95 135112

Soil on Wall Submerged EV 1.35 65.5 87.89 5757 7772 8.79 68317

Active Soil Dry EH 1.50 125 0.28 9 11.45 1431 2147 13.00 27908

Active Soil Submerged EH 1.50 65.5 0.28 10 25.44 1667 2500 5.00 12499

Active Soil Submerged EH 1.50 65.5 0.28 10 14.14 926 1389 3.33 4629

Height (Ft) 19.00 16737 34204 285860 140523

Toe (Ft) 2.50 tan φf 0.625 ∑FHorizontal ∑FVertical ∑MResisting ∑MOverturning

Heal (Ft) 11.50 C 0.9 RR = CV tan φf 19236

Foundation (Ft) 14.00 Foundation/3 4.67 σV 4025 e 2.75 b' 8.5

TYPE 3 SEGMENT - STORM EVENT

Project St Thomas Veterans Drive Date 5/30/2023

Subject Wall Segment Design Check - Storm Event - Extreme 1 min Checked by RS/SWL

Date 9/25/2023

Filename = C:\Users\Lawsons\Desktop\Wall CADD Files\Veterans Drive St Thomas\Calculations\[Counterfort Wall Design and Bearing Resistance_RS_9-25-23.xlsx]Summary

COMPUTATION SHEET

Item Side Load Load

Factor γ

(pcf)

Ka φf=34° h

(Ft)

Volume

(CuFt)

Horizontal

Load

(Lb)

Factored

(Lb)

Vertical

Loads

(Lb)

Factored

(Lb)

Moment Arm

(Ft)

MResisting

(Ft Lb)

MOverturning

(Ft Lb)

Water Passive WA 1.00 64 10 3200 3200 3.33 10667

Water Active WA 1.00 64 19 11552 11552 6.33 73163

Wall Coping DC 0.90 150 8.25 1238 1114 3.49 3887

Wall Dry DC 0.90 150 8.04 1206 1085 3.62 3929

Wall Submerged DC 0.90 86 30.23 2600 2340 5.97 13969

LL on Wall LS 1.75 250 11.5 2875 5031.25 8.25 41508

LL Active LS 1.75 250 0.28 19 5.37 1343 2350 9.5 22324

Mooring 1.75

Soil on Wall Dry EV 1.00 125 89.46 11182 11182 8.95 100083

Soil on Wall Submerged EV 1.00 65.5 87.89 5757 5757 8.79 50605

Active Soil Dry EH 0.90 125 0.28 9 11.45 1431 1288 13.00 16745

Active Soil Submerged EH 0.90 65.5 0.28 10 25.44 1667 1500 5.00 7499

Active Soil Submerged EH 0.90 65.5 0.28 10 14.14 926 833 3.33 2778

Height (Ft) 19.00 14323 26510 224648 122509

Toe (Ft) 2.50 tan φf 0.625 ∑FHorizontal ∑FVertical ∑MResisting ∑MOverturning

Heal (Ft) 11.50 C 0.9 RR = CV tan φf 14909

Foundation (Ft) 14.00 Foundation/3 4.67 σV 3440 e 3.15 b' 7.7

TYPE 3 SEGMENT - STORM EVENT

5.97

8.04

DC 150 pcf

30.23

DC 86 pcf

3.49

.0

.0

8.95

8.79

8.25

11.50

3.62

2.50 11.50

14.00

.0

.0

.3

WA 64 pcf

.5

.0

.3

.0

.0

125 pcf ka

EH

65.5 pcf ka

EH

65.5 pcf ka

EH

WA 64 pcf

250 psf ka

LS

.3

LS 250 psf

87.89

EV 65.5 pcf

3.25

TYPE 3 SEGMENT - STORM EVENT

24.1°

89.46

TYPE 4 SEGMENT

Project St Thomas Veterans Drive Date 5/30/2023

Subject Wall Segment Design Check - Normal Tide - Strenght 1 max Checked by RS/SWL

Date 9/25/2023

Filename = C:\Users\Lawsons\Desktop\Wall CADD Files\Veterans Drive St Thomas\Calculations\[Counterfort Wall Design and Bearing Resistance_RS_9-25-23.xlsx]Summary

COMPUTATION SHEET

Item Side Load Load

Factor γ

(pcf)

Ka φf=34° h

(Ft)

Volume

(CuFt)

Horizontal

Load

(Lb)

Factored

(Lb)

Vertical

Loads

(Lb)

Factored

(Lb)

Moment Arm

(Ft)

MResisting

(Ft Lb)

MOverturning

(Ft Lb)

Water Passive WA 1.00 64 17 9248 9248 5.67 52405

Water Active WA 1.00 64 17 9248 9248 5.67 52405

Wall Coping DC 1.25 150 8.25 1238 1547 3.99 6172

Wall Dry DC 1.25 150 3.21 482 602 3.90 2349

Wall Submerged DC 1.25 86 42.61 3664 4581 6.43 29453

LL on Wall LS 1.75 250 13 3250 5687.5 9.50 54031

LL Active LS 1.75 250 0.28 22 6.22 1555 2721 11.00 29931

Mooring LL 1.75 1000 1750 22.00 38500

Soil on Wall Dry EV 1.35 125 55.79 6974 9415 10.36 97535

Soil on Wall Submerged EV 1.35 65.5 182.14 11930 16106 10.05 161863

Active Soil Dry EH 1.50 125 0.28 5 3.53 442 663 18.67 12368

Active Soil Submerged EH 1.50 65.5 0.28 17 24.03 1574 2361 8.50 20068

Active Soil Submerged EH 1.50 65.5 0.28 17 40.85 2676 4014 5.67 22743

Height (Ft) 22.00 11508 37938 403808 176015

Toe (Ft) 3.00 tan φf 0.625 ∑FHorizontal ∑FVertical ∑MResisting ∑MOverturning

Heal (Ft) 13.00 C 0.9 RR = CV tan φf 21335

Foundation (Ft) 16.00 Foundation/3 5.33 σV 3159 e 2.00 b' 12.0

TYPE 4 SEGMENT - NORMAL TIDE

Project St Thomas Veterans Drive Date 5/30/2023

Subject Wall Segment Design Check - Normal Tide - Strength 1 min Checked by RS/SWL

Date 9/25/2023

Filename = C:\Users\Lawsons\Desktop\Wall CADD Files\Veterans Drive St Thomas\Calculations\[Counterfort Wall Design and Bearing Resistance_RS_9-25-23.xlsx]Summary

COMPUTATION SHEET

Item Side Load Load

Factor γ

(pcf)

Ka φf=34° h

(Ft)

Volume

(CuFt)

Horizontal

Load

(Lb)

Factored

(Lb)

Vertical

Loads

(Lb)

Factored

(Lb)

Moment Arm

(Ft)

MResisting

(Ft Lb)

MOverturning

(Ft Lb)

Water Passive WA 1.00 64 17 9248 9248 5.67 52405

Water Active WA 1.00 64 17 9248 9248 5.67 52405

Wall Coping DC 0.90 150 8.25 1238 1114 3.99 4444

Wall Dry DC 0.90 150 3.21 482 434 3.90 1691

Wall Submerged DC 0.90 86 42.61 3664 3298 6.43 21206

LL on Wall LS 1.75 250 13 3250 5687.5 9.50 54031

LL Active LS 1.75 250 0.28 22 6.22 1555 2721 11.00 29931

Mooring LL 1.75 1000 1750 22.00 38500

Soil on Wall Dry EV 1.00 125 55.79 6974 6974 10.36 72248

Soil on Wall Submerged EV 1.00 65.5 182.14 11930 11930 10.05 119898

Active Soil Dry EH 0.90 125 0.28 5 3.53 442 398 18.67 7421

Active Soil Submerged EH 0.90 65.5 0.28 17 24.03 1574 1417 8.50 12041

Active Soil Submerged EH 0.90 65.5 0.28 17 40.85 2676 2408 5.67 13646

Height (Ft) 22.00 8693 29437 325924 153944

Toe (Ft) 3.00 tan φf 0.625 ∑FHorizontal ∑FVertical ∑MResisting ∑MOverturning

Heal (Ft) 13.00 C 0.9 RR = CV tan φf 16555

Foundation (Ft) 16.00 Foundation/3 5.33 σV 2519 e 2.16 b' 11.7

TYPE 4 SEGMENT - NORMAL TIDE

6.43

3.21

DC 150 pcf

182.14

EV 65.5 pcf

42.61

DC 86 pcf

3.99

.0

.0

10.36

10.05

9.50

13.00

3.90

3.00 13.00

.0

.6

3.75

WA 64 pcf

16.00

LS 250 psf

.0

.0

.6

WA 64 pcf

.0

.6

.5

.6

250 psf ka

LS

125 pcf ka

EH

65.5 pcf ka

EH

65.5 pcf ka

EH

TYPE 4 SEGMENT - NORMAL TIDES

55.79

Project St Thomas Veterans Drive Date 5/30/2023

Subject Wall Segment Design Check - Storm Event - Extreme 1 max Checked by RS/SWL

Date 9/25/2023

Filename = C:\Users\Lawsons\Desktop\Wall CADD Files\Veterans Drive St Thomas\Calculations\[Counterfort Wall Design and Bearing Resistance_RS_9-25-23.xlsx]Summary

COMPUTATION SHEET

Item Side Load Load

Factor γ

(pcf)

Ka φf=34° h

(Ft)

Volume

(CuFt)

Horizontal

Load

(Lb)

Factored

(Lb)

Vertical

Loads

(Lb)

Factored

(Lb)

Moment Arm

(Ft)

MResisting

(Ft Lb)

MOverturning

(Ft Lb)

Water Passive WA 1.00 64 12 4608 4608 4.00 18432

Water Active WA 1.00 64 22 15488 15488 7.33 113579

Wall Coping DC 1.25 150 8.25 1238 1547 3.99 6172

Wall Dry DC 1.25 150 9.34 1402 1752 4.18 7324

Wall Submerged DC 1.25 86 36.48 3137 3921 6.79 26625

LL on Wall LS 1.75 250 13 3250 5687.5 9.50 54031

LL Active LS 1.75 250 0.28 22 6.22 1555 2721 11.00 29931

Mooring 1.75

Soil on Wall Dry EV 1.35 125 114.66 14332 19348 10.20 197351

Soil on Wall Submerged EV 1.35 65.5 123.27 8074 10901 10.06 109659

Active Soil Dry EH 1.50 125 0.28 10 14.14 1767 2650 15.33 40638

Active Soil Submerged EH 1.50 65.5 0.28 12 33.92 2222 3333 6.00 19998

Active Soil Submerged EH 1.50 65.5 0.28 12 20.35 1333 2000 4.00 7999

Height (Ft) 22.00 21584 43156 419594 212145

Toe (Ft) 3.00 tan φf 0.625 ∑FHorizontal ∑FVertical ∑MResisting ∑MOverturning

Heal (Ft) 13.00 C 0.9 RR = CV tan φf 24270

Foundation (Ft) 16.00 Foundation/3 5.33 σV 4489 e 3.19 b' 9.6

TYPE 4 SEGMENT - STORM EVENT

Project St Thomas Veterans Drive Date 5/30/2023

Subject Wall Segment Design Check - Storm Event - Extreme 1 min Checked by RS/SWL

Date 9/25/2023

Filename = C:\Users\Lawsons\Desktop\Wall CADD Files\Veterans Drive St Thomas\Calculations\[Counterfort Wall Design and Bearing Resistance_RS_9-25-23.xlsx]Summary

COMPUTATION SHEET

Item Side Load Load

Factor γ

(pcf)

Ka φf=34° h

(Ft)

Volume

(CuFt)

Horizontal

Load

(Lb)

Factored

(Lb)

Vertical

Loads

(Lb)

Factored

(Lb)

Moment Arm

(Ft)

MResisting

(Ft Lb)

MOverturning

(Ft Lb)

Water Passive WA 1.00 64 12 4608 4608 4.00 18432

Water Active WA 1.00 64 22 15488 15488 7.33 113579

Wall Coping DC 0.90 150 8.25 1238 1114 3.99 4444

Wall Dry DC 0.90 150 9.34 1402 1261 4.18 5273

Wall Submerged DC 0.90 86 36.48 3137 2823 6.79 19170

LL on Wall LS 1.75 250 13 3250 5687.5 9.50 54031

LL Active LS 1.75 250 0.28 22 6.22 1555 2721 11.00 29931

Mooring 1.75

Soil on Wall Dry EV 1.00 125 114.66 14332 14332 10.20 146186

Soil on Wall Submerged EV 1.00 65.5 123.27 8074 8074 10.06 81229

Active Soil Dry EH 0.90 125 0.28 10 14.14 1767 1590 15.33 24383

Active Soil Submerged EH 0.90 65.5 0.28 12 33.92 2222 2000 6.00 11999

Active Soil Submerged EH 0.90 65.5 0.28 12 20.35 1333 1200 4.00 4800

Height (Ft) 22.00 18391 33292 328765 184691

Toe (Ft) 3.00 tan φf 0.625 ∑FHorizontal ∑FVertical ∑MResisting ∑MOverturning

Heal (Ft) 13.00 C 0.9 RR = CV tan φf 18723

Foundation (Ft) 16.00 Foundation/3 5.33 σV 3847 e 3.67 b' 8.7

TYPE 4 SEGMENT - STORM EVENT

6.79

9.34

DC 150 pcf

123.27

EV 65.5 pcf

36.48

DC 86 pcf

3.99

.0

.0

10.20

10.06

9.50

13.00

4.18

3.00 13.00

.0

.0

.3

.3

.0

3.75

125 pcf ka

EH

65.5 pcf ka

EH

65.5 pcf ka

EH

WA 64 pcf

250 psf ka

LS

.0

16.00

LS 250 psf

.0

.0

.0

WA 64 pcf

TYPE 4 SEGMENT - STORM EVENT

24.44°

114.66

TYPE 5 SEGMENT

Project St Thomas Veterans Drive Date 5/30/2023

Subject Wall Segment Design Check - Normal Tide - Strenght 1 max Checked by RS/SWL

Date 9/25/2023

Filename = C:\Users\Lawsons\Desktop\Wall CADD Files\Veterans Drive St Thomas\Calculations\[Counterfort Wall Design and Bearing Resistance_RS_9-25-23.xlsx]Summary

COMPUTATION SHEET

Item Side Load Load

Factor γ

(pcf)

Ka φf=34° h

(Ft)

Volume

(CuFt)

Horizontal

Load

(Lb)

Factored

(Lb)

Vertical

Loads

(Lb)

Factored

(Lb)

Moment Arm

(Ft)

MResisting

(Ft Lb)

MOverturning

(Ft Lb)

Water Passive WA 1.00 64 20 12800 12800 6.67 85333

Water Active WA 1.00 64 20 12800 12800 6.67 85333

Wall Coping DC 1.25 150 8.25 1238 1547 4.49 6945

Wall Dry DC 1.25 150 3.21 482 602 4.40 2650

Wall Submerged DC 1.25 86 50.51 4344 5430 7.21 39149

LL on Wall LS 1.75 250 14.5 3625 6343.75 10.50 66609

LL Active LS 1.75 250 0.28 25 7.07 1767 3092 12.50 38650

Mooring LL 1.75 1000 1750 25.00 43750

Soil on Wall Dry EV 1.35 125 63.21 7901 10667 11.62 123947

Soil on Wall Submerged EV 1.35 65.5 243.87 15973 21564 11.32 244107

Active Soil Dry EH 1.50 125 0.28 5 3.53 442 663 21.67 14356

Active Soil Submerged EH 1.50 65.5 0.28 20 28.27 1852 2778 10.00 27775

Active Soil Submerged EH 1.50 65.5 0.28 20 56.54 3703 5555 6.67 37034

Height (Ft) 25.00 13837 46154 568741 246899

Toe (Ft) 3.50 tan φf 0.625 ∑FHorizontal ∑FVertical ∑MResisting ∑MOverturning

Heal (Ft) 14.50 C 0.9 RR = CV tan φf 25956

Foundation (Ft) 18.00 Foundation/3 6.00 σV 3309 e 2.03 b' 13.9

TYPE 5 SEGMENT - NORMAL TIDE

Project St Thomas Veterans Drive Date 5/30/2023

Subject Wall Segment Design Check - Normal Tide - Strength 1 min Checked by RS/SWL

Date 9/25/2023

Filename = C:\Users\Lawsons\Desktop\Wall CADD Files\Veterans Drive St Thomas\Calculations\[Counterfort Wall Design and Bearing Resistance_RS_9-25-23.xlsx]Summary

COMPUTATION SHEET

Item Side Load Load

Factor γ

(pcf)

Ka φf=34° h

(Ft)

Volume

(CuFt)

Horizontal

Load

(Lb)

Factored

(Lb)

Vertical

Loads

(Lb)

Factored

(Lb)

Moment Arm

(Ft)

MResisting

(Ft Lb)

MOverturning

(Ft Lb)

Water Passive WA 1.00 64 20 12800 12800 6.67 85333

Water Active WA 1.00 64 20 12800 12800 6.67 85333

Wall Coping DC 0.90 150 8.25 1238 1114 4.49 5001

Wall Dry DC 0.90 150 3.21 482 434 4.40 1908

Wall Submerged DC 0.90 86 50.51 4344 3909 7.21 28187

LL on Wall LS 1.75 250 14.5 3625 6343.75 10.50 66609

LL Active LS 1.75 250 0.28 25 7.07 1767 3092 12.50 38650

Mooring LL 1.75 1000 1750 25.00 43750

Soil on Wall Dry EV 1.00 125 63.21 7901 7901 11.62 91813

Soil on Wall Submerged EV 1.00 65.5 243.87 15973 15973 11.32 180820

Active Soil Dry EH 0.90 125 0.28 5 3.53 442 398 21.67 8614

Active Soil Submerged EH 0.90 65.5 0.28 20 28.27 1852 1667 10.00 16665

Active Soil Submerged EH 0.90 65.5 0.28 20 56.54 3703 3333 6.67 22220

Height (Ft) 25.00 10239 35675 459671 215233

Toe (Ft) 3.50 tan φf 0.625 ∑FHorizontal ∑FVertical ∑MResisting ∑MOverturning

Heal (Ft) 14.50 C 0.9 RR = CV tan φf 20063

Foundation (Ft) 18.00 Foundation/3 6.00 σV 2603 e 2.15 b' 13.7

TYPE 5 SEGMENT - NORMAL TIDE

7.21

3.21

DC 150 pcf

243.87

EV 65.5 pcf

50.51

DC 86 pcf

4.49

.0

.0

11.62

11.32

10.50

14.50

4.40

LS 250 psf

63.29

EV 125 pcf

4.25

WA 64 pcf

.6

.0

.0

.5

.0

.6

.6

.0

.6

250 psf ka

LS

125 pcf ka

EH

65.5 pcf ka

EH

65.5 pcf ka

EH

WA 64 pcf

TYPE 5 SEGMENT - NORMAL TIDES

3.50 14.50

Project St Thomas Veterans Drive Date 5/30/2023

Subject Wall Segment Design Check - Storm Event - Extreme 1 max Checked by RS/SWL

Date 9/25/2023

Filename = C:\Users\Lawsons\Desktop\Wall CADD Files\Veterans Drive St Thomas\Calculations\[Counterfort Wall Design and Bearing Resistance_RS_9-25-23.xlsx]Summary

COMPUTATION SHEET

Item Side Load Load

Factor γ

(pcf)

Ka φf=34° h

(Ft)

Volume

(CuFt)

Horizontal

Load

(Lb)

Factored

(Lb)

Vertical

Loads

(Lb)

Factored

(Lb)

Moment Arm

(Ft)

MResisting

(Ft Lb)

MOverturning

(Ft Lb)

Water Passive WA 1.00 64 15 7200 7200 5.00 36000

Water Active WA 1.00 64 25 20000 20000 8.33 166667

Wall Coping DC 1.25 150 8.25 1238 1547 4.49 6945

Wall Dry DC 1.25 150 9.34 1402 1752 4.68 8200

Wall Submerged DC 1.25 86 44.38 3816 4770 7.54 35969

LL on Wall LS 1.75 250 14.5 3625 6343.75 10.50 66609

LL Active LS 1.75 250 0.28 25 7.07 1767 3092 12.50 38650

Mooring 1.75

Soil on Wall Dry EV 1.35 125 129.66 16207 21879 11.45 250519

Soil on Wall Submerged EV 1.35 65.5 177.50 11626 15695 11.33 177828

Active Soil Dry EH 1.50 125 0.28 10 14.14 1767 2650 18.33 48589

Active Soil Submerged EH 1.50 65.5 0.28 15 42.41 2778 4166 7.50 31247

Active Soil Submerged EH 1.50 65.5 0.28 15 31.80 2083 3125 5.00 15624

Height (Ft) 25.00 25833 51988 582071 300777

Toe (Ft) 3.50 tan φf 0.625 ∑FHorizontal ∑FVertical ∑MResisting ∑MOverturning

Heal (Ft) 14.50 C 0.9 RR = CV tan φf 29237

Foundation (Ft) 18.00 Foundation/3 6.00 σV 4804 e 3.59 b' 10.8

TYPE 5 SEGMENT - STORM EVENT

Project St Thomas Veterans Drive Date 5/30/2023

Subject Wall Segment Design Check - Storm Event - Extreme 1 min Checked by RS/SWL

Date 9/25/2023

Filename = C:\Users\Lawsons\Desktop\Wall CADD Files\Veterans Drive St Thomas\Calculations\[Counterfort Wall Design and Bearing Resistance_RS_9-25-23.xlsx]Summary

COMPUTATION SHEET

Item Side Load Load

Factor γ

(pcf)

Ka φf=34° h

(Ft)

Volume

(CuFt)

Horizontal

Load

(Lb)

Factored

(Lb)

Vertical

Loads

(Lb)

Factored

(Lb)

Moment Arm

(Ft)

MResisting

(Ft Lb)

MOverturning

(Ft Lb)

Water Passive WA 1.00 64 15 7200 7200 5.00 36000

Water Active WA 1.00 64 25 20000 20000 8.33 166667

Wall Coping DC 0.90 150 8.25 1238 1114 4.49 5001

Wall Dry DC 0.90 150 9.34 1402 1261 4.68 5904

Wall Submerged DC 0.90 86 44.38 3816 3435 7.54 25898

LL on Wall LS 1.75 250 14.5 3625 6343.75 10.50 66609

LL Active LS 1.75 250 0.28 25 7.07 1767 3092 12.50 38650

Mooring 1.75

Soil on Wall Dry EV 1.00 125 129.66 16207 16207 11.45 185570

Soil on Wall Submerged EV 1.00 65.5 177.50 11626 11626 11.33 131725

Active Soil Dry EH 0.90 125 0.28 10 14.14 1767 1590 18.33 29153

Active Soil Submerged EH 0.90 65.5 0.28 15 42.41 2778 2500 7.50 18748

Active Soil Submerged EH 0.90 65.5 0.28 15 31.80 2083 1875 5.00 9374

Height (Ft) 25.00 21857 39987 456706 262593

Toe (Ft) 3.50 tan φf 0.625 ∑FHorizontal ∑FVertical ∑MResisting ∑MOverturning

Heal (Ft) 14.50 C 0.9 RR = CV tan φf 22488

Foundation (Ft) 18.00 Foundation/3 6.00 σV 4119 e 4.15 b' 9.7

7.54

9.34

DC 150 pcf

177.50

EV 65.5 pcf

44.38

DC 86 pcf

4.49

.0

.0

11.45

11.33

10.50

14.50

4.68

3.50 10.25 4.25

LS 250 psf

129.66

EV 125 pcf

4.25

WA 64 pcf

.0

.0

.0

.5

.0

.3

.3

.5

.0

250 psf ka

LS

125 pcf ka

EH

65.5 pcf ka

EH

65.5 pcf ka

EH

WA 64 pcf

24.7°

TYPE 6 SEGMENT

Project St Thomas Veterans Drive Date 5/30/2023

Subject Wall Segment Design Check - Normal Tide - Strenght 1 max Checked by RS/SWL

Date 9/25/2023

Filename = C:\Users\Lawsons\Desktop\Wall CADD Files\Veterans Drive St Thomas\Calculations\[Counterfort Wall Design and Bearing Resistance_RS_9-25-23.xlsx]Summary

COMPUTATION SHEET

Item Side Load Load

Factor γ

(pcf)

Ka φf=34° h

(Ft)

Volume

(CuFt)

Horizontal

Load

(Lb)

Factored

(Lb)

Vertical

Loads

(Lb)

Factored

(Lb)

Moment Arm

(Ft)

MResisting

(Ft Lb)

MOverturning

(Ft Lb)

Water Passive WA 1.00 64 23 16928 16928 7.67 129781

Water Active WA 1.00 64 23 16928 16928 7.67 129781

Wall Coping DC 1.25 150 8.25 1238 1547 4.99 7719

Wall Dry DC 1.25 150 3.21 482 602 4.90 2951

Wall Submerged DC 1.25 86 58.76 5053 6316 7.99 50469

LL on Wall LS 1.75 250 16 4000 7000 12.00 84000

LL Active LS 1.75 250 0.28 28 7.92 1979 3463 14.00 48483

Mooring LL 1.75 1000 1750 28.00 49000

Soil on Wall Dry EV 1.35 125 70.79 8848 11945 12.87 153737

Soil on Wall Submerged EV 1.35 65.5 314.24 20583 27787 12.60 350115

Active Soil Dry EH 1.50 125 0.28 5 3.53 442 663 24.67 16344

Active Soil Submerged EH 1.50 65.5 0.28 23 32.51 2129 3194 11.50 36733

Active Soil Submerged EH 1.50 65.5 0.28 23 74.77 4898 7347 7.67 56324

Height (Ft) 28.00 16416 55198 778772 336664

Toe (Ft) 4.00 tan φf 0.625 ∑FHorizontal ∑FVertical ∑MResisting ∑MOverturning

Heal (Ft) 16.00 C 0.9 RR = CV tan φf 31042

Foundation (Ft) 20.00 Foundation/3 6.67 σV 3446 e 1.99 b' 16.0

TYPE 6 SEGMENT - NORMAL TIDE

Project St Thomas Veterans Drive Date 5/30/2023

Subject Wall Segment Design Check - Normal Tide - Strength 1 min Checked by RS/SWL

Date 9/25/2023

Filename = C:\Users\Lawsons\Desktop\Wall CADD Files\Veterans Drive St Thomas\Calculations\[Counterfort Wall Design and Bearing Resistance_RS_9-25-23.xlsx]Summary

COMPUTATION SHEET

Item Side Load Load

Factor γ

(pcf)

Ka φf=34° h

(Ft)

Volume

(CuFt)

Horizontal

Load

(Lb)

Factored

(Lb)

Vertical

Loads

(Lb)

Factored

(Lb)

Moment Arm

(Ft)

MResisting

(Ft Lb)

MOverturning

(Ft Lb)

Water Passive WA 1.00 64 23 16928 16928 7.67 129781

Water Active WA 1.00 64 23 16928 16928 7.67 129781

Wall Coping DC 0.90 150 8.25 1238 1114 4.99 5558

Wall Dry DC 0.90 150 3.21 482 434 4.90 2125

Wall Submerged DC 0.90 86 58.76 5053 4548 7.99 36337

LL on Wall LS 1.75 250 16 4000 7000 12.00 84000

LL Active LS 1.75 250 0.28 28 7.92 1979 3463 14.00 48483

Mooring LL 1.75 1000 1750 28.00 49000

Soil on Wall Dry EV 1.00 125 70.79 8848 8848 12.87 113879

Soil on Wall Submerged EV 1.00 65.5…