This file is a miscellaneous calculations worksheet related to construction cost estimation for the Veterans Drive Contract 2 Improvements project on Route 30. The document appears to contain detailed mathematical computations and cost breakdowns used to support the overall project budget and pricing analysis. The calculations likely encompass various cost categories such as labor, materials, equipment, and contingencies necessary for the highway improvement work being solicited under solicitation number 693C73-27-R-000012. As a supporting calculation document rather than a primary contract requirement specification, it functions as a reference tool for contractors and the contracting agency to understand the basis for estimated costs and pricing terms associated with this Federal Highway Administration project administered by the Department of Transportation.
View the file
Other files
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Page
STRUCTURES DESIGN
FINAL CALCULATIONS
VETERANS DRIVE IMPROVEMENTS
STATION 198+36.26 TO STATION 236+68.54
FEDERAL PROJECT ID
DCP-34(1)
PREPARED FOR
UNITED STATES VIRGIN ISLANDS
DEPARTMENT OF PUBLIC WORKS
PREPARED BY
WSP USA
5411 SKYCENTER DRIVE
SUITE 650
TAMPA, FL 33607
APPROVED BY: SCOTT R. LAWSON P.E. NO. 1295-E
MARCH 2024
Contents
WALL STRUCTURES DESIGN CRITERIA
Site Conditions
Geotechnical Conditions
Hydraulic Conditions
WALL LOADS
Dead Load (DC)
Live Loads (LS)
Horizontal Earth (HV) and Vertical Earth Pressure (EV)
Seismic Loads
Water Loads (WA)
Scour
WALL DESIGN PROCEDURE
Sliding
Eccentricity
Bearing Capacity
Load Combinations and Load Factors
Resistance Factors
WALL SEGMENT DESIGN
TYPE 0 SEGMENT
TYPE 1 SEGMENT
TYPE 2 SEGMENT
TYPE 3 SEGMENT
TYPE 4 SEGMENT
TYPE 5 SEGMENT
TYPE 6 SEGMENT
WALL SEGMENT REINFORCEMENT
BOX CULVERT CD2 EXTENSION
BOX CULVERT CD3 EXTENSION
TYPE A AND B LIGHT POLES
SIGNAL MASTARMS
WALL STRUCTURES DESIGN CRITERIA
Site Conditions The seawall retains fill for roadway widening and new waterfront parks from station 198+36.26 to 236+68.54. Portions of the wall will be placed in front of an existing tied sheet pile wall. The existing sheet pile wall was originally constructed in 1954. The PGL of the new roadway varies from 3.94’ to 6.49’ above the MLLW.
Geotechnical Conditions The soils at the site are grouped into four stratums: Fill, Soft Clay and Silt, Alluvium and Bedrock. Soils that have the potential for liquefaction during a seismic event will be removed and replaced with new fill as specified in the geotechnical report.
Hydraulic Conditions Static and Dynamic wave loads as shown in the coastal Engineering report are used in the design of the wall. The permitted footprint of the wall does not allow for the addition of toe protection. Since there is no toe protection the wall is designed for the maximum scour depth as calculated in the hydraulic report.
WALL LOADS
Dead Load (DC) Reinforced Concrete 150 lb/ft3
Live Loads (LS) Live loads will be applied to the wall as a surcharge.
HL-93 Live 250 lb/ft3
Horizontal Earth (HV) and Vertical Earth Pressure (EV) The lateral earth pressures for PMB walls are defined in AASHTO 3.11.5.9.
Moist Unit Weight 125 lb/ft3
Saturated Unit Weight 65.5 = (129.5-64) lb/ft3
Rankine theory is used to calculate Ka and Kp. (AASHTO C3.11.5.9-1 and 3.11.5.3). The benefit of passive soil loads in front of the wall are ignored.
ܽܭ = (2/ߔ-45)ଶ݊ܽݐ
ܭ = (2/ߔ+45)ଶ݊ܽݐ
Seismic Loads As per AASHTO 11.5.4.2 Seismic design is not mandatory for walls in seismic zones 1 through 3, or for walls at sites where the site adjusted peak ground acceleration, AS is less than or equal to 0.4g, unless there is potential for liquefaction induced lateral spreading or if the wall supports another structure which is required to be designed for seismic loading. AASHTO A11.2 states that walls designed using the static method typically do not experience significant damage in locations where the site adjusted peak ground acceleration is below 0.5g.
The site adjusted peak ground acceleration, AS =0.36g.
Seismic design of the wall is not required.
Water Loads (WA) Static water pressure 64 lb/ft3
Buoyancy 64 lb/ft3
In the coastal engineering report, the dynamic water pressures have been calculated for the 100 years storm event. The dynamic pressures are not used since they are offset by passive soil loads behind the wall.
Location
Wave Crest Wave Trough Dynamic Pressure
At Top of Wall (lb/Ft2)
Dynamic Pressure At Mudline
(lb/Ft2)
Wave Trough Elevation
(Ft)
Dynamic Pressure At Mudline
(lb/Ft2) Sta. 198+50 922 876 -6.1 443 Sta. 200+40 911 858 -7.5 545 Sta. 202+40 913 861 -7.0 511 Sta. 204+40 915 864 -7.0 511 Sta. 206+40 915 864 -7.0 511 Sta. 208+40 1018 955 -6.6 477 Sta. 210+40 1025 967 -6.1 443 Sta. 212+30 990 937 -5.6 409 Sta. 213+00 1024 965 -6.1 443 Sta. 214+10 1010 943 -7.5 545 Sta. 216+15 1012 945 -7.5 545 Sta. 218+15 1010 943 -7.5 545 Sta. 220+10 1016 952 -7.0 511 Sta. 222+00 1024 965 -6.1 443 Sta. 223+00 1012 959 -6.1 443 Sta. 224+70 1025 980 -4.7 340 Sta. 225+50 852 822 -2.8 204 Sta. 226+20 831 803 -2.8 204 Sta. 227+80 1055 1008 -3.7 272 Sta. 228+50 1055 1008 -4.7 340 Sta. 229+00 1144 1083 -6.1 443 Sta. 229+50 1144 1083 -5.4 392 Sta. 231+00 831 803 -2.8 204 Sta. 232+30 1144 1083 -5.9 426 Sta. 232+90 1144 1083 -6.3 460 Sta. 233+20 1144 1083 -4.9 358 Sta. 234+20 1055 1008 -3.3 238 Sta. 235+20 873 841 -2.3 170 Sta. 236+70 703 682 -1.4 102
Scour In the coastal engineering report, the scour elevations have been calculated for the 100 years storm event. The scour elevations will be used for all load cases.
Location Mudline Elevation (Ft, MMLW)
Scour Depth (Ft)
Scour Elevation (Ft, MMLW)
Sta. 198+50 -13.0 6.0 -19.0 Sta. 200+40 -16.0 4.8 -20.8 Sta. 202+40 -15.0 4.7 -19.7 Sta. 204+40 -15.0 4.7 -19.7 Sta. 206+40 -15.0 4.6 -19.6 Sta. 208+40 -14.0 6.7 -20.7 Sta. 210+40 -13.0 8.4 -21.4 Sta. 212+30 -12.0 8.4 -20.4 Sta. 213+00 -13.0 8.4 -21.4 Sta. 214+10 -16.0 6.7 -22.7 Sta. 216+15 -16.0 6.7 -22.7 Sta. 218+15 -16.0 6.7 -22.7 Sta. 220+10 -15.0 6.7 -21.7 Sta. 222+00 -13.0 5.4 -18.4 Sta. 223+00 -7.0 4.7 -11.7 Sta. 224+70 -10.0 5.1 -15.1 Sta. 225+50 -6.0 4.7 -10.7 Sta. 226+20 -6.0 11.7 -17.7 Sta. 227+80 -8.0 7.5 -15.5 Sta. 228+50 -10.0 7.7 -17.7 Sta. 229+00 -13.0 6.5 -19.5 Sta. 229+50 -11.5 9.2 -20.7 Sta. 231+00 -6.0 5.5 -11.5 Sta. 232+30 -12.5 8.0 -20.5 Sta. 232+90 -13.5 6.1 -19.6 Sta. 233+20 -10.5 5.8 -16.3 Sta. 234+20 -7.0 8.5 -15.5 Sta. 235+20 -5.0 7.3 -12.3 Sta. 236+70 -3.0 3.8 -6.8
WALL DESIGN PROCEDURE
The following checks are made for the tallest of each wall type.
Sliding Sliding is checked (AASHTO 10.6.3.4) between the base block and the gravel or concrete leveling pad, and between each block layer.
ܴோ = ܴ߮ோ = ߮ఛܴఛ + ܴ߮
ܴோ = ݈ܽ݊݅݉݊ ݈݃݊݅݀݅ݏ ݁ܿ݊ܽݐݏ݅ݏ݁ݎ ݐݏ݊݅ܽ݃ܽ ݁ݎݑ݈݂݅ܽ ݕܾ ݈݃݊݅݀݅ݏ
߮ఛ = ݁ܿ݊ܽݐݏ݅ݏ݁ݎ ݎݐ݂ܿܽ ݎ݂ ݎℎ݁ܽݏ ݁ܿ݊ܽݐݏ݅ݏ݁ݎ ݊݁݁ݓݐܾ݁ ݈݅ݏ ܽ݊݀ ݊݅ݐܽ݀݊ݑ݂
ܴఛ = ݈ܽ݊݅݉݊ ݈݃݊݅݀݅ݏ ݁ܿ݊ܽݐݏ݅ݏ݁ݎ ݊݁݁ݓݐܾ݁ ݈݅ݏ ܽ݊݀ ݊݅ݐܽ݀݊ݑ݂
߮ = ݁ܿ݊ܽݐݏ݅ݏ݁ݎ ݎݐ݂ܿܽ ݎ݂ ݁ݒ݅ݏݏܽ ݁ܿ݊ܽݐݏ݅ݏ݁ݎ
ܴ = ݈ܽ݊݅݉݊ ݁ܿ݅ݏݏܽ ݁ܿ݊ܽݐݏ݅ݏ݁ݎ ݂ ݈݅ݏ
Eccentricity Eccentricity Limits (AASHTO 11.6.3.3) for block on the gravel leveling pad are e/L<0.33, for block on rock or concrete leveling pad e/L<0.45. The eccentricity limit for block on block is treated the same as block on rock.
ܮ ܯ∑) (ܯ∑−
݁ = ݕݐ݅ܿ݅ݎݐ݊݁ܿܿ݁
ܯ = ݉ݑݏ ݂ ݃݊݅ݐݏ݅ݏ݁ݎ ݏݐ݊݁݉݉
ܯ = ݉ݑݏ ݂ ݃݊݅݊ݎݑݐݎ݁ݒ ݏݐ݊݁݉݉
ܸ = ݉ݑݏ ݂ ݈ܽܿ݅ݐݎ݁ݒ ݏ݁ܿݎ݂
Bearing Capacity Vertical stress (AASHTO 11.6.3.2) shall be used to check bearing resistance. The calculated ultimate bearing capacity is shown in the geotechnical report.
௩ߪ =
ܤ − 2݁
௩ߪ = ݈ܽܿ݅ݐݎ݁ݒ ݈݅ݏ ݏݏ݁ݎݐݏ ݅݊ ݈݅ݏ
ܤ = ݈݈ܽݓ ݁ݏܾܽ ℎݐ݀݅ݓ
Load Combinations and Load Factors AASHTO Table 3.4.1-1 and 3.4.1-2
Load Factors
Strength I (Maximum)
Strength I (Minimum)
Extreme I (Maximum)
Extreme I (Minimum) Service
DL 1.25 0.90 1.25 0.90 1.00
LL surcharge Mooring 1.75 0 1.00
EH
Active 1.50 0.90 1.50 0.90 1.00
EH
At Rest 1.35 0.90 1.35 0.90 1.00
EV 1.35 1.00 1.35 1.00 1.00
WA
(Static) 1.00
WA
(Dynamic) 0 1.00 0
Resistance Factors AASHTO Table 10.5.5.2.2-1
Resistance Factors Strength I
Bearing Resistance 0.45
Precast Concrete to Stone 0.90
Stone to Soil 0.90
Passive
EP 0.50
WALL SEGMENT DESIGN
Made by SRL
Project St Thomas Veterans Drive Date 5/30/2023
Subject Wall Segment Design Check - Summary Checked by RS/SWL
Date 9/25/2023
Filename = C:\Users\Lawsons\Desktop\Wall CADD Files\Veterans Drive St Thomas\Calculations\[Counterfort Wall Design and Bearing Resistance_RS_9-25-23.xlsx]Summary
Segment ∑MResisting ∑MOverturning
Factor of
Safety
Foundation
Width/3
(Ft) e
(Ft) Check ∑Fhorizontal
(Lb)
∑Fvertical
(Lb)
RR = CV tan φf
(Lb)
Check σV
(Lb/SqFt) CDR Bearing B' (ft)
Factored
Bearing
Resistance
(psf)
Check
TYPE 0 52287 13171 4.0 2.67 0.76 OK 2615 12069 6787 OK 1862 1.34 6.5 2487.0 OK
TYPE 1 105410 29132 3.6 3.33 0.78 OK 4270 18066 10160 OK 2139 2.32 8.4 4973.0 OK
TYPE 2 176042 52985 3.3 4.00 0.85 OK 5850 23887 13433 OK 2318 2.44 10.3 5665.0 OK
TYPE 3 273691 121537 2.3 4.67 2.01 OK 9429 30511 17159 OK 3059 1.85 10.0 5665.0 OK
TYPE 4 403808 176015 2.3 5.33 2.00 OK 11508 37938 21335 OK 3159 1.79 12.0 5665.0 OK
TYPE 5 568741 246899 2.3 6.00 2.03 OK 13837 46154 25956 OK 3309 1.71 13.9 5665.0 OK
TYPE 6 778772 336664 2.3 6.67 1.99 OK 16416 55198 31042 OK 3446 1.64 16.0 5665.0 OK
Segment ∑MResisting ∑MOverturning
Factor of
Safety
Foundation
Width/3
(Ft) e
(Ft) Check ∑Fhorizontal
(Lb)
∑Fvertical
(Lb)
RR = CV tan φf
(Lb)
Check σV
(Lb/SqFt) CDR Bearing B' (ft)
Factored
Bearing
Resistance
(psf)
Check
TYPE 0 46172 11556 4.0 2.67 0.67 OK 2259 10381 5838 OK 1557 2.40 6.7 3730.0 OK
TYPE 1 84737 23844 3.6 3.33 0.73 OK 3205 14255 8017 OK 1668 2.98 8.5 4973.0 OK
TYPE 2 141585 43802 3.2 4.00 0.78 OK 4301 18721 10529 OK 1792 3.16 10.4 5665.0 OK
TYPE 3 220492 106859 2.1 4.67 2.22 OK 7297 23783 13375 OK 2489 2.28 9.6 5665.0 OK
TYPE 4 325924 153944 2.1 5.33 2.16 OK 8693 29437 16555 OK 2519 2.25 11.7 5665.0 OK
TYPE 5 459671 215233 2.1 6.00 2.15 OK 10239 35675 20063 OK 2603 2.18 13.7 5665.0 OK
TYPE 6 631025 292904 2.2 6.67 2.05 OK 11935 42527 23916 OK 2674 2.12 15.9 5665.0 OK
Segment ∑MResisting ∑MOverturning
Factor of
Safety
Foundation
Width/3
(Ft) e
(Ft) Check ∑Fhorizontal
(Lb)
∑Fvertical
(Lb)
RR = CV tan φf
(Lb)
Check σV
(Lb/SqFt) CDR Bearing B' (ft)
Factored
Bearing
Resistance
(psf)
Check
TYPE 0 54165 23132 2.3 2.67 1.99 OK 5443 12634 7105 OK 2572 1.18 4.9 3046.0 OK
TYPE 1 110108 49207 2.2 3.33 1.87 OK 8829 19429 10927 OK 3099 1.20 6.3 3730.0 OK
TYPE 2 184165 87095 2.1 4.00 2.31 OK 12486 26295 14788 OK 3561 1.22 7.4 4351.0 OK
TYPE 3 285860 140523 2.0 4.67 2.75 OK 16737 34204 19236 OK 4025 1.24 8.5 4973.0 OK
TYPE 4 419594 212145 2.0 5.33 3.19 OK 21584 43156 24270 OK 4489 1.23 9.6 5532.0 OK
TYPE 5 582071 300777 1.9 6.00 3.59 OK 25833 51988 29237 OK 4804 1.18 10.8 5665.0 OK
TYPE 6 687481 387350 1.8 6.67 4.41 OK 27767 53663 30179 OK 4797 1.18 11.2 5665.0 OK
Segment ∑MResisting ∑MOverturning
Factor of
Safety
Foundation
Width/3
(Ft) e
(Ft) Check
∑Fhorizontal
(Lb)
∑Fvertical
(Lb)
RR = CV tan φf
(Lb)
Check σV
(Lb/SqFt) CDR Bearing B' (ft)
Factored
Bearing
Resistance
(psf)
Check
TYPE 0 47372 21263 2.2 2.67 1.58 OK 5031 10795 6071 OK 2232 1.11 4.8 2487.0 OK
TYPE 1 87387 43079 2.0 3.33 2.10 OK 7643 15261 8583 OK 2628 1.18 5.8 3108.0 OK
TYPE 2 145319 76066 1.9 4.00 2.62 OK 10740 20499 11528 OK 3034 1.23 6.8 3730.0 OK
TYPE 3 224648 122509 1.8 4.67 3.15 OK 14323 26510 14909 OK 3440 1.26 7.7 4351.0 OK
TYPE 4 224648 122509 1.8 4.67 3.15 OK 14323 26510 14909 OK 3847 1.29 8.7 4973.0 OK
TYPE 5 328765 184691 1.8 5.33 3.67 OK 18391 33292 18723 OK 4119 1.34 9.7 5532.0 OK
TYPE 6 456706 262593 1.7 6.67 4.49 OK 25473 47275 26587 OK 4288 1.32 11.0 5665.0 OK
Factored Bearing Resistance Values are hard entered from Nominal Bearing Resistances tab. Lookups are for the values of effective footing width B' rounded down to the nearest whole distance. This is conservative.
* The factored bearing resistance for this row is specifically calculated on the nominal bearing resistance tab, as the rounded down approach does not check.
DESIGN SUMMARY - STORM EVENT (Extreme 1min)
DESIGN SUMMARY - STORM EVENT (Extreme 1max)
DESIGN SUMMARY - NORMAL TIDE (Strength 1min)
DESIGN SUMMARY - NORMAL TIDE (Strength 1max)
COMPUTATION SHEET
TYPE 0 SEGMENT
Project St Thomas Veterans Drive Date 5/30/2023
Subject Wall Segment Design Check - Normal Tide - Strenght 1 max Checked by RS/SWL
Date 9/25/2023
Filename = C:\Users\Lawsons\Desktop\Wall CADD Files\Veterans Drive St Thomas\Calculations\[Counterfort Wall Design and Bearing Resistance_RS_9-25-23.xlsx]Summary
COMPUTATION SHEET
Item Side Load Load
Factor γ
(pcf)
Ka φf=34° h
(Ft)
Volume
(CuFt)
Horizontal
Load
(Lb)
Factored
(Lb)
Vertical
Loads
(Lb)
Factored
(Lb)
Moment Arm
(Ft)
MResisting
(Ft Lb)
MOverturning
(Ft Lb)
Water Passive WA 1.00 64 5 800 800 1.67 1333
Water Active WA 1.00 64 5 800 800 1.67 1333
Wall Coping DC 1.25 150 8.25 1238 1547 1.99 3078
Wall Dry DC 1.25 150 3.21 482 602 1.90 1144
Wall Submerged DC 1.25 86 14.51 1248 1560 3.46 5397
LL on Wall LS 1.75 250 7 1750 3062.5 4.50 13781
LL Active LS 1.75 250 0.28 10 2.83 707 1237 5.00 6184
Mooring LL 1.75
Soil on Wall Dry EV 1.35 110 25.79 2837 3830 5.29 20260
Soil on Wall Submerged EV 1.35 50 21.74 1087 1467 4.97 7293
Active Soil Dry EH 1.50 110 0.28 5 3.53 389 583 6.67 3887
Active Soil Submerged EH 1.50 50 0.28 5 7.07 353 530 2.50 1325
Active Soil Submerged EH 1.50 50 0.28 5 3.53 177 265 1.67 442
Height (Ft) 10.00 2615 12069 52287 13171
Toe (Ft) 1.00 tan φf 0.625 ∑FHorizontal ∑FVertical ∑MResisting ∑MOverturning
Heal (Ft) 7.00 C 0.9 RR = CV tan φf 6787
Foundation (Ft) 8.00 Foundation/3 2.67 σV 1862 e 0.76 b' 6.5
TYPE 0 SEGMENT - NORMAL TIDE
Project St Thomas Veterans Drive Date 5/30/2023
Subject Wall Segment Design Check - Normal Tide - Strength 1 min Checked by RS/SWL
Date 9/25/2023
Filename = C:\Users\Lawsons\Desktop\Wall CADD Files\Veterans Drive St Thomas\Calculations\[Counterfort Wall Design and Bearing Resistance_RS_9-25-23.xlsx]Summary
COMPUTATION SHEET
Item Side Load Load
Factor γ
(pcf)
Ka φf=34° h
(Ft)
Volume
(CuFt)
Horizontal
Load
(Lb)
Factored
(Lb)
Vertical
Loads
(Lb)
Factored
(Lb)
Moment Arm
(Ft)
MResisting
(Ft Lb)
MOverturning
(Ft Lb)
Water Passive WA 1.00 64 5 800 800 1.67 1333
Water Active WA 1.00 64 5 800 800 1.67 1333
Wall Coping DC 0.90 150 8.25 1238 1114 1.99 2216
Wall Dry DC 0.90 150 3.21 482 434 1.90 824
Wall Submerged DC 0.90 86 14.51 1248 1123 3.46 3886
LL on Wall LS 1.75 250 7 1750 3062.5 4.50 13781
LL Active LS 1.75 250 0.28 10 2.83 707 1237 5.00 6184
Mooring LL 1.75
Soil on Wall Dry EV 1.00 125 25.79 3224 3224 5.29 17054
Soil on Wall Submerged EV 1.00 65.5 21.74 1424 1424 4.97 7077
Active Soil Dry EH 0.90 125 0.28 5 3.53 442 398 6.67 2650
Active Soil Submerged EH 0.90 65.5 0.28 5 7.07 463 417 2.50 1042
Active Soil Submerged EH 0.90 65.5 0.28 5 3.53 231 208 1.67 347
Height (Ft) 10.00 2259 10381 46172 11556
Toe (Ft) 1.00 tan φf 0.625 ∑FHorizontal ∑FVertical ∑MResisting ∑MOverturning
Heal (Ft) 7.00 C 0.9 RR = CV tan φf 5838
Foundation (Ft) 8.00 Foundation/3 2.67 σV 1557 e 0.67 b' 6.7
TYPE 0 SEGMENT - NORMAL TIDE
1.90
.0
.6
DC 150 pcf
3.21
DC 150 pcf
21.74
EV 65.5 pcf
14.51
DC 86 pcf
TYPE 0 SEGMENT - NORMAL TIDE
3.46
1.99
.0
.0
5.29
4.97
4.50
7.00
8.00
.0
.0
WA 64 pcf
.6
WA 64 pcf 5 .0
0 6 .6
.5
125 pcf ka
EH
65.5 pcf ka
EH
65.5 pcf ka
EH
250 psf ka
LS
.6
LS 250 psf
1.75
7.001.00
25.79
EV 125 pcf
Project St Thomas Veterans Drive Date 5/30/2023
Subject Wall Segment Design Check - Storm Event - Extreme 1 max Checked by RS/SWL
Date 9/25/2023
Filename = C:\Users\Lawsons\Desktop\Wall CADD Files\Veterans Drive St Thomas\Calculations\[Counterfort Wall Design and Bearing Resistance_RS_9-25-23.xlsx]Summary
COMPUTATION SHEET
Item Side Load Load
Factor γ
(pcf)
Ka φf=34° h
(Ft)
Volume
(CuFt)
Horizontal
Load
(Lb)
Factored
(Lb)
Vertical
Loads
(Lb)
Factored
(Lb)
Moment Arm
(Ft)
MResisting
(Ft Lb)
MOverturning
(Ft Lb)
Water Passive WA 1.00 64 4 512 512 1.33 683
Water Active WA 1.00 64 10 3200 3200 3.33 10667
Wall Coping DC 1.25 150 8.25 1238 1547 1.99 3078
Wall Dry DC 1.25 150 4.36 654 818 1.96 1603
Wall Submerged DC 1.25 86 13.36 1149 1436 3.57 5127
LL on Wall LS 1.75 250 7 1750 3062.5 4.5 13781
LL Active LS 1.75 250 0.28 10 2.83 707 1237 5 6184
Mooring 1.75
Soil on Wall Dry EV 1.35 110 31.64 3480 4698 5.23 24573
Soil on Wall Submerged EV 1.35 50 15.89 795 1073 4.96 5320
Active Soil Dry EH 1.50 110 0.28 6 5.09 560 840 6.00 5038
Active Soil Submerged EH 1.50 50 0.28 4 6.78 339 509 2.00 1018
Active Soil Submerged EH 1.50 50 0.28 4 2.26 113 170 1.33 226
Height (Ft) 10.00 5443 12634 54165 23132
Toe (Ft) 1.00 tan φf 0.625 ∑FHorizontal ∑FVertical ∑MResisting ∑MOverturning
Heal (Ft) 7.00 C 0.9 RR = CV tan φf 7105
Foundation (Ft) 8.00 Foundation/3 2.67 σV 2572 e 1.54 b' 4.9
TYPE 0 SEGMENT - STORM EVENT
Project St Thomas Veterans Drive Date 5/30/2023
Subject Wall Segment Design Check - Storm Event - Extreme 1 min Checked by RS/SWL
Date 9/25/2023
Filename = C:\Users\Lawsons\Desktop\Wall CADD Files\Veterans Drive St Thomas\Calculations\[Counterfort Wall Design and Bearing Resistance_RS_9-25-23.xlsx]Summary
COMPUTATION SHEET
Item Side Load Load
Factor γ
(pcf)
Ka φf=34° h
(Ft)
Volume
(CuFt)
Horizontal
Load
(Lb)
Factored
(Lb)
Vertical
Loads
(Lb)
Factored
(Lb)
Moment Arm
(Ft)
MResisting
(Ft Lb)
MOverturning
(Ft Lb)
Water Passive WA 1.00 64 4 512 512 1.33 683
Water Active WA 1.00 64 10 3200 3200 3.33 10667
Wall Coping DC 0.90 150 8.25 1238 1114 1.99 2216
Wall Dry DC 0.90 150 4.36 654 589 1.96 1154
Wall Submerged DC 0.90 86 13.36 1149 1034 3.57 3691
LL on Wall LS 1.75 250 7 1750 3062.5 4.5 13781
LL Active LS 1.75 250 0.28 10 2.83 707 1237 5 6184
Mooring 1.75
Soil on Wall Dry EV 1.00 125 31.64 3955 3955 5.23 20684
Soil on Wall Submerged EV 1.00 65.5 15.89 1041 1041 4.96 5163
Active Soil Dry EH 0.90 125 0.28 6 5.09 636 572 6.00 3435
Active Soil Submerged EH 0.90 65.5 0.28 4 6.78 444 400 2.00 800
Active Soil Submerged EH 0.90 65.5 0.28 4 2.26 148 133 1.33 178
Height (Ft) 10.00 5031 10795 47372 21263
Toe (Ft) 1.00 tan φf 0.625 ∑FHorizontal ∑FVertical ∑MResisting ∑MOverturning
Heal (Ft) 7.00 C 0.9 RR = CV tan φf 6071
Foundation (Ft) 8.00 Foundation/3 2.67 σV 2232 e 1.58 b' 4.8
TYPE 0 SEGMENT - STORM EVENT
13.36
DC 86 pcf
1.96
.0
.0
.3
4.36
DC 150 pcf
15.89
EV 65.5 pcf
DC 150 pcf
WA 64 pcf 250 psf ka
LS
TYPE 0 SEGMENT - STORM EVENT
3.57
1.99
.0
.0
5.23
4.96
4.50
7.00
8.00
7.001.00
.0
.0
.0
.0
125 pcf ka
EH
65.5 pcf ka
EH
65.5 pcf ka
EH
.3
.3
WA 64 pcf
LS 250 psf
21.8°
31.64
TYPE 1 SEGMENT
Project St Thomas Veterans Drive Date 5/30/2023
Subject Wall Segment Design Check - Normal Tide - Strenght 1 max Checked by RS/SWL
Date 9/25/2023
Filename = C:\Users\Lawsons\Desktop\Wall CADD Files\Veterans Drive St Thomas\Calculations\[Counterfort Wall Design and Bearing Resistance_RS_9-25-23.xlsx]Summary
COMPUTATION SHEET
Item Side Load Load
Factor γ
(pcf)
Ka φf=34° h
(Ft)
Volume
(CuFt)
Horizontal
Load
(Lb)
Factored
(Lb)
Vertical
Loads
(Lb)
Factored
(Lb)
Moment Arm
(Ft)
MResisting
(Ft Lb)
MOverturning
(Ft Lb)
Water Passive WA 1.00 64 8 2048 2048 2.67 5461
Water Active WA 1.00 64 8 2048 2048 2.67 5461
Wall Coping DC 1.25 150 8.25 1238 1547 2.49 3852
Wall Dry DC 1.25 150 3.21 482 602 2.40 1446
Wall Submerged DC 1.25 86 21.01 1807 2259 4.16 9396
LL on Wall LS 1.75 250 8.5 2125 3718.75 5.75 21383
LL Active LS 1.75 250 0.28 13 3.68 919 1608 6.50 10451
Mooring LL 1.75
Soil on Wall Dry EV 1.35 125 33.29 4161 5618 6.57 36908
Soil on Wall Submerged EV 1.35 65.5 48.87 3201 4321 6.24 26965
Active Soil Dry EH 1.50 125 0.28 5 3.53 442 663 9.67 6405
Active Soil Submerged EH 1.50 65.5 0.28 8 11.31 741 1111 4.00 4444
Active Soil Submerged EH 1.50 65.5 0.28 8 9.05 593 889 2.67 2370
Height (Ft) 13.00 4270 18066 105410 29132
Toe (Ft) 1.50 tan φf 0.625 ∑FHorizontal ∑FVertical ∑MResisting ∑MOverturning
Heal (Ft) 8.50 C 0.9 RR = CV tan φf 10160
Foundation (Ft) 10.00 Foundation/3 3.33 σV 2139 e 0.78 b' 8.4
TYPE 1 SEGMENT - NORMAL TIDE
Project St Thomas Veterans Drive Date 5/30/2023
Subject Wall Segment Design Check - Normal Tide - Strength 1 min Checked by RS/SWL
Date 9/25/2023
Filename = C:\Users\Lawsons\Desktop\Wall CADD Files\Veterans Drive St Thomas\Calculations\[Counterfort Wall Design and Bearing Resistance_RS_9-25-23.xlsx]Summary
COMPUTATION SHEET
Item Side Load Load
Factor γ
(pcf)
Ka φf=34° h
(Ft)
Volume
(CuFt)
Horizontal
Load
(Lb)
Factored
(Lb)
Vertical
Loads
(Lb)
Factored
(Lb)
Moment Arm
(Ft)
MResisting
(Ft Lb)
MOverturning
(Ft Lb)
Water Passive WA 1.00 64 8 2048 2048 2.67 5461
Water Active WA 1.00 64 8 2048 2048 2.67 5461
Wall Coping DC 0.90 150 8.25 1238 1114 2.49 2773
Wall Dry DC 0.90 150 3.21 482 434 2.40 1041
Wall Submerged DC 0.90 86 21.01 1807 1626 4.16 6765
LL on Wall LS 1.75 250 8.5 2125 3718.75 5.75 21383
LL Active LS 1.75 250 0.28 13 3.68 919 1608 6.50 10451
Mooring LL 1.75
Soil on Wall Dry EV 1.00 125 33.29 4161 4161 6.57 27339
Soil on Wall Submerged EV 1.00 65.5 48.87 3201 3201 6.24 19974
Active Soil Dry EH 0.90 125 0.28 5 3.53 442 398 9.67 3843
Active Soil Submerged EH 0.90 65.5 0.28 8 11.31 741 667 4.00 2666
Active Soil Submerged EH 0.90 65.5 0.28 8 9.05 593 533 2.67 1422
Height (Ft) 13.00 3205 14255 84737 23844
Toe (Ft) 1.50 tan φf 0.625 ∑FHorizontal ∑FVertical ∑MResisting ∑MOverturning
Heal (Ft) 8.50 C 0.9 RR = CV tan φf 8017
Foundation (Ft) 10.00 Foundation/3 3.33 σV 1668 e 0.73 b' 8.5
TYPE 1 SEGMENT - NORMAL TIDE
2.40
DC 150 pcf
3.21
DC 150 pcf
21.01
DC 86 pcf
48.87
EV 65.5 pcf
TYPE 1 SEGMENT - NORMAL TIDE
4.16
2.49
.0
.0
.0
6.57
6.24
5.75
8.50
10.00
8.501.50
.0
.0
.6
WA 64 pcf
LS 250 psf
.5
.6
.6
.0
125 pcf ka
EH
65.5 pcf ka
EH
65.5 pcf ka
EH
WA 64 pcf
250 psf ka
LS
.6
.0
33.29
Project St Thomas Veterans Drive Date 5/30/2023
Subject Wall Segment Design Check - Storm Event - Extreme 1 max Checked by RS/SWL
Date 9/25/2023
Filename = C:\Users\Lawsons\Desktop\Wall CADD Files\Veterans Drive St Thomas\Calculations\[Counterfort Wall Design and Bearing Resistance_RS_9-25-23.xlsx]Summary
COMPUTATION SHEET
Item Side Load Load
Factor γ
(pcf)
Ka φf=34° h
(Ft)
Volume
(CuFt)
Horizontal
Load
(Lb)
Factored
(Lb)
Vertical
Loads
(Lb)
Factored
(Lb)
Moment Arm
(Ft)
MResisting
(Ft Lb)
MOverturning
(Ft Lb)
Water Passive WA 1.00 64 6 1152 1152 2.00 2304
Water Active WA 1.00 64 13 5408 5408 4.33 23435
Wall Coping DC 1.25 150 8.25 1238 1547 2.49 3852
Wall Dry DC 1.25 150 5.55 832 1040 2.51 2611
Wall Submerged DC 1.25 86 18.67 1606 2007 4.35 8731
LL on Wall LS 1.75 250 8.5 2125 3718.75 5.75 21383
LL Active LS 1.75 250 0.28 13 3.68 919 1608 6.5 10451
Mooring 1.75
Soil on Wall Dry EV 1.35 125 47.95 5994 8092 6.47 52354
Soil on Wall Submerged EV 1.35 65.5 34.20 2240 3024 6.24 18872
Active Soil Dry EH 1.50 125 0.28 7 6.93 866 1299 8.33 10822
Active Soil Submerged EH 1.50 65.5 0.28 6 11.87 778 1167 3.00 3500
Active Soil Submerged EH 1.50 65.5 0.28 6 5.09 333 500 2.00 1000
Height (Ft) 13.00 8829 19429 110108 49207
Toe (Ft) 1.50 tan φf 0.625 ∑FHorizontal ∑FVertical ∑MResisting ∑MOverturning
Heal (Ft) 8.50 C 0.9 RR = CV tan φf 10927
Foundation (Ft) 10.00 Foundation/3 3.33 σV 3099 e 1.87 b' 6.3
TYPE 1 SEGMENT - STORM EVENT
Project St Thomas Veterans Drive Date 5/30/2023
Subject Wall Segment Design Check - Storm Event - Extreme 1 min Checked by RS/SWL
Date 9/25/2023
Filename = C:\Users\Lawsons\Desktop\Wall CADD Files\Veterans Drive St Thomas\Calculations\[Counterfort Wall Design and Bearing Resistance_RS_9-25-23.xlsx]Summary
COMPUTATION SHEET
Item Side Load Load
Factor γ
(pcf)
Ka φf=34° h
(Ft)
Volume
(CuFt)
Horizontal
Load
(Lb)
Factored
(Lb)
Vertical
Loads
(Lb)
Factored
(Lb)
Moment Arm
(Ft)
MResisting
(Ft Lb)
MOverturning
(Ft Lb)
Water Passive WA 1.00 64 6 1152 1152 2.00 2304
Water Active WA 1.00 64 13 5408 5408 4.33 23435
Wall Coping DC 0.90 150 8.25 1238 1114 2.49 2773
Wall Dry DC 0.90 150 5.55 832 749 2.51 1880
Wall Submerged DC 0.90 86 18.67 1606 1445 4.35 6287
LL on Wall LS 1.75 250 8.5 2125 3718.75 5.75 21383
LL Active LS 1.75 250 0.28 13 3.68 919 1608 6.5 10451
Mooring 1.75
Soil on Wall Dry EV 1.00 125 47.95 5994 5994 6.47 38781
Soil on Wall Submerged EV 1.00 65.5 34.20 2240 2240 6.24 13980
Active Soil Dry EH 0.90 125 0.28 7 6.93 866 779 8.33 6493
Active Soil Submerged EH 0.90 65.5 0.28 6 11.87 778 700 3.00 2100
Active Soil Submerged EH 0.90 65.5 0.28 6 5.09 333 300 2.00 600
Height (Ft) 13.00 7643 15261 87387 43079
Toe (Ft) 1.50 tan φf 0.625 ∑FHorizontal ∑FVertical ∑MResisting ∑MOverturning
Heal (Ft) 8.50 C 0.9 RR = CV tan φf 8583
Foundation (Ft) 10.00 Foundation/3 3.33 σV 2628 e 2.10 b' 5.8
TYPE 1 SEGMENT - STORM EVENT
2.51
5.55
DC 150 pcf
18.67
DC 86 pcf
34.20
EV 65.5 pcf
TYPE 1 SEGMENT - STORM EVENT
4.35
2.49
.0
.0
.0
6.47
6.24
5.75
8.50
10.00
8.501.50
.0
.0
.5
.0
.3
.3
.0
125 pcf ka
EH
65.5 pcf ka
EH
65.5 pcf ka
EH
WA 64 pcf250 psf ka
LS
.0
.0
WA 64 pcf
LS 250 psf
22.93°
47.95
TYPE 2 SEGMENT
Project St Thomas Veterans Drive Date 5/30/2023
Subject Wall Segment Design Check - Normal Tide - Strenght 1 max Checked by RS/SWL
Date 9/25/2023
Filename = C:\Users\Lawsons\Desktop\Wall CADD Files\Veterans Drive St Thomas\Calculations\[Counterfort Wall Design and Bearing Resistance_RS_9-25-23.xlsx]Summary
COMPUTATION SHEET
Item Side Load Load
Factor γ
(pcf)
Ka φf=34° h
(Ft)
Volume
(CuFt)
Horizontal
Load
(Lb)
Factored
(Lb)
Vertical
Loads
(Lb)
Factored
(Lb)
Moment Arm
(Ft)
MResisting
(Ft Lb)
MOverturning
(Ft Lb)
Water Passive WA 1.00 64 11 3872 3872 3.67 14197
Water Active WA 1.00 64 11 3872 3872 3.67 14197
Wall Coping DC 1.25 150 8.25 1238 1547 2.99 4625
Wall Dry DC 1.25 150 3.21 482 602 2.90 1747
Wall Submerged DC 1.25 86 27.86 2396 2995 4.90 14675
LL on Wall LS 1.75 250 10 2500 4375 7.00 30625
LL Active LS 1.75 250 0.28 16 4.52 1131 1979 8.00 15831
Mooring LL 1.75
Soil on Wall Dry EV 1.35 125 40.79 5099 6883 7.84 53965
Soil on Wall Submerged EV 1.35 65.5 84.64 5544 7484 7.51 56207
Active Soil Dry EH 1.50 125 0.28 5 3.53 442 663 12.67 8393
Active Soil Submerged EH 1.50 65.5 0.28 11 15.55 1018 1528 5.50 8402
Active Soil Submerged EH 1.50 65.5 0.28 11 17.10 1120 1680 3.67 6161
Height (Ft) 16.00 5850 23887 176042 52985
Toe (Ft) 2.00 tan φf 0.625 ∑FHorizontal ∑FVertical ∑MResisting ∑MOverturning
Heal (Ft) 10.00 C 0.9 RR = CV tan φf 13433
Foundation (Ft) 12.00 Foundation/3 4.00 σV 2318 e 0.85 b' 10.3
TYPE 2 SEGMENT - NORMAL TIDE
Project St Thomas Veterans Drive Date 5/30/2023
Subject Wall Segment Design Check - Normal Tide - Strength 1 min Checked by RS/SWL
Date 9/25/2023
Filename = C:\Users\Lawsons\Desktop\Wall CADD Files\Veterans Drive St Thomas\Calculations\[Counterfort Wall Design and Bearing Resistance_RS_9-25-23.xlsx]Summary
COMPUTATION SHEET
Item Side Load Load
Factor γ
(pcf)
Ka φf=34° h
(Ft)
Volume
(CuFt)
Horizontal
Load
(Lb)
Factored
(Lb)
Vertical
Loads
(Lb)
Factored
(Lb)
Moment Arm
(Ft)
MResisting
(Ft Lb)
MOverturning
(Ft Lb)
Water Passive WA 1.00 64 11 3872 3872 3.67 14197
Water Active WA 1.00 64 11 3872 3872 3.67 14197
Wall Coping DC 0.90 150 8.25 1238 1114 2.99 3330
Wall Dry DC 0.90 150 3.21 482 434 2.90 1258
Wall Submerged DC 0.90 86 27.86 2396 2156 4.90 10566
LL on Wall LS 1.75 250 10 2500 4375 7.00 30625
LL Active LS 1.75 250 0.28 16 4.52 1131 1979 8.00 15831
Mooring LL 1.75
Soil on Wall Dry EV 1.00 125 40.79 5099 5099 7.84 39974
Soil on Wall Submerged EV 1.00 65.5 84.64 5544 5544 7.51 41635
Active Soil Dry EH 0.90 125 0.28 5 3.53 442 398 12.67 5036
Active Soil Submerged EH 0.90 65.5 0.28 11 15.55 1018 917 5.50 5041
Active Soil Submerged EH 0.90 65.5 0.28 11 17.10 1120 1008 3.67 3697
Height (Ft) 16.00 4301 18721 141585 43802
Toe (Ft) 2.00 tan φf 0.625 ∑FHorizontal ∑FVertical ∑MResisting ∑MOverturning
Heal (Ft) 10.00 C 0.9 RR = CV tan φf 10529
Foundation (Ft) 12.00 Foundation/3 4.00 σV 1792 e 0.78 b' 10.4
TYPE 2 SEGMENT - NORMAL TIDE
2.90
3.21
DC 150 pcf
84.64
EV 65.5 pcf
27.86
DC 86 pcf
4.90
2.99
.0
.0
7.84
7.51
7.00
10.00
12.00
2.00 10.00
.6
WA 64 pcf
.0
.0
2.75
LS 250 psf
TYPE 2 SEGMENT - NORMAL TIDE
.0
.6
.6
.5
125 pcf ka
EH
65.5 pcf ka
EH
65.5 pcf ka
EH
WA 64 pcf
250 psf ka
LS
.6
.0
40.79
Project St Thomas Veterans Drive Date 5/30/2023
Subject Wall Segment Design Check - Storm Event - Extreme 1 max Checked by RS/SWL
Date 9/25/2023
Filename = C:\Users\Lawsons\Desktop\Wall CADD Files\Veterans Drive St Thomas\Calculations\[Counterfort Wall Design and Bearing Resistance_RS_9-25-23.xlsx]Summary
COMPUTATION SHEET
Item Side Load Load
Factor γ
(pcf)
Ka φf=34° h
(Ft)
Volume
(CuFt)
Horizontal
Load
(Lb)
Factored
(Lb)
Vertical
Loads
(Lb)
Factored
(Lb)
Moment Arm
(Ft)
MResisting
(Ft Lb)
MOverturning
(Ft Lb)
Water Passive WA 1.00 64 8 2048 2048 2.67 5461
Water Active WA 1.00 64 16 8192 8192 5.33 43691
Wall Coping DC 1.25 150 8.25 1238 1547 2.99 4625
Wall Dry DC 1.25 150 6.78 1016 1270 3.06 3887
Wall Submerged DC 1.25 86 24.30 2089 2612 5.15 13450
LL on Wall LS 1.75 250 10 2500 4375 7.00 30625
LL Active LS 1.75 250 0.28 16 4.52 1131 1979 8.00 15831
Mooring 1.75
Soil on Wall Dry EV 1.35 125 67.23 8403 11344 7.71 87464
Soil on Wall Submerged EV 1.35 65.5 58.20 3812 5147 7.51 38652
Active Soil Dry EH 1.50 125 0.28 8 9.05 1131 1696 10.67 18093
Active Soil Submerged EH 1.50 65.5 0.28 8 18.09 1185 1778 4.00 7110
Active Soil Submerged EH 1.50 65.5 0.28 8 9.05 593 889 2.67 2370
Height (Ft) 16.00 12486 26295 184165 87095
Toe (Ft) 2.00 tan φf 0.625 ∑FHorizontal ∑FVertical ∑MResisting ∑MOverturning
Heal (Ft) 10.00 C 0.9 RR = CV tan φf 14788
Foundation (Ft) 12.00 Foundation/3 4.00 σV 3561 e 2.31 b' 7.4
TYPE 2 SEGMENT - STORM EVENT
Project St Thomas Veterans Drive Date 5/30/2023
Subject Wall Segment Design Check - Storm Event - Extreme 1 min Checked by RS/SWL
Date 9/25/2023
Filename = C:\Users\Lawsons\Desktop\Wall CADD Files\Veterans Drive St Thomas\Calculations\[Counterfort Wall Design and Bearing Resistance_RS_9-25-23.xlsx]Summary
COMPUTATION SHEET
Item Side Load Load
Factor γ
(pcf)
Ka φf=34° h
(Ft)
Volume
(CuFt)
Horizontal
Load
(Lb)
Factored
(Lb)
Vertical
Loads
(Lb)
Factored
(Lb)
Moment Arm
(Ft)
MResisting
(Ft Lb)
MOverturning
(Ft Lb)
Water Passive WA 1.00 64 8 2048 2048 2.67 5461
Water Active WA 1.00 64 16 8192 8192 5.33 43691
Wall Coping DC 0.90 150 8.25 1238 1114 2.99 3330
Wall Dry DC 0.90 150 6.78 1016 915 3.06 2799
Wall Submerged DC 0.90 86 24.30 2089 1880 5.15 9684
LL on Wall LS 1.75 250 10 2500 4375 7.00 30625
LL Active LS 1.75 250 0.28 16 4.52 1131 1979 8.00 15831
Mooring 1.75
Soil on Wall Dry EV 1.00 125 67.23 8403 8403 7.71 64788
Soil on Wall Submerged EV 1.00 65.5 58.20 3812 3812 7.51 28631
Active Soil Dry EH 0.90 125 0.28 8 9.05 1131 1018 10.67 10856
Active Soil Submerged EH 0.90 65.5 0.28 8 18.09 1185 1067 4.00 4266
Active Soil Submerged EH 0.90 65.5 0.28 8 9.05 593 533 2.67 1422
Height (Ft) 16.00 10740 20499 145319 76066
Toe (Ft) 2.00 tan φf 0.625 ∑FHorizontal ∑FVertical ∑MResisting ∑MOverturning
Heal (Ft) 10.00 C 0.9 RR = CV tan φf 11528
Foundation (Ft) 12.00 Foundation/3 4.00 σV 3034 e 2.62 b' 6.8
TYPE 2 SEGMENT - STORM EVENT
3.06
6.77
DC 150 pcf
58.20
EV 65.5 pcf
24.30
DC 86 pcf
5.15
2.99
.0
.0
7.71
7.51
7.00
10.00
12.00
2.00 10.00
.6
WA 64 pcf
.0
.0
.0
.0
.3
.6
.0
125 pcf ka
EH
65.5 pcf ka
EH
65.5 pcf ka
EH
WA 64 pcf
250 psf ka
LS
.6
2.75
LS 250 psf
TYPE 2 SEGMENT - STORM EVENT
23.63°
67.22
TYPE 3 SEGMENT
Project St Thomas Veterans Drive Date 5/30/2023
Subject Wall Segment Design Check - Normal Tide - Strenght 1 max Checked by RS/SWL
Date 9/25/2023
Filename = C:\Users\Lawsons\Desktop\Wall CADD Files\Veterans Drive St Thomas\Calculations\[Counterfort Wall Design and Bearing Resistance_RS_9-25-23.xlsx]Summary
COMPUTATION SHEET
Item Side Load Load
Factor γ
(pcf)
Ka φf=34° h
(Ft)
Volume
(CuFt)
Horizontal
Load
(Lb)
Factored
(Lb)
Vertical
Loads
(Lb)
Factored
(Lb)
Moment Arm
(Ft)
MResisting
(Ft Lb)
MOverturning
(Ft Lb)
Water Passive WA 1.00 64 14 6272 6272 4.67 29269
Water Active WA 1.00 64 14 6272 6272 4.67 29269
Wall Coping DC 1.25 150 8.25 1238 1547 3.49 5399
Wall Dry DC 1.25 150 3.21 482 602 3.40 2048
Wall Submerged DC 1.25 86 35.06 3015 3769 5.60 21106
LL on Wall LS 1.75 250 11.5 2875 5031.25 8.25 41508
LL Active LS 1.75 250 0.28 19 5.37 1343 2350 9.50 22324
Mooring LL 1.75 1000 1750 19.00 33250
Soil on Wall Dry EV 1.35 125 48.29 6036 8149 9.10 74155
Soil on Wall Submerged EV 1.35 65.5 129.07 8454 11413 8.78 100206
Active Soil Dry EH 1.50 125 0.28 5 3.53 442 663 15.67 10380
Active Soil Submerged EH 1.50 65.5 0.28 14 19.79 1296 1944 7.00 13610
Active Soil Submerged EH 1.50 65.5 0.28 14 27.70 1815 2722 4.67 12703
Height (Ft) 19.00 9429 30511 273691 121537
Toe (Ft) 2.50 tan φf 0.625 ∑FHorizontal ∑FVertical ∑MResisting ∑MOverturning
Heal (Ft) 11.50 C 0.9 RR = CV tan φf 17159
Foundation (Ft) 14.00 Foundation/3 4.67 σV 3059 e 2.01 b' 10.0
TYPE 3 SEGMENT - NORMAL TIDE
Project St Thomas Veterans Drive Date 5/30/2023
Subject Wall Segment Design Check - Normal Tide - Strength 1 min Checked by RS/SWL
Date 9/25/2023
Filename = C:\Users\Lawsons\Desktop\Wall CADD Files\Veterans Drive St Thomas\Calculations\[Counterfort Wall Design and Bearing Resistance_RS_9-25-23.xlsx]Summary
COMPUTATION SHEET
Item Side Load Load
Factor γ
(pcf)
Ka φf=34° h
(Ft)
Volume
(CuFt)
Horizontal
Load
(Lb)
Factored
(Lb)
Vertical
Loads
(Lb)
Factored
(Lb)
Moment Arm
(Ft)
MResisting
(Ft Lb)
MOverturning
(Ft Lb)
Water Passive WA 1.00 64 14 6272 6272 4.67 29269
Water Active WA 1.00 64 14 6272 6272 4.67 29269
Wall Coping DC 0.90 150 8.25 1238 1114 3.49 3887
Wall Dry DC 0.90 150 3.21 482 434 3.40 1475
Wall Submerged DC 0.90 86 35.06 3015 2714 5.60 15196
LL on Wall LS 1.75 250 11.5 2875 5031.25 8.25 41508
LL Active LS 1.75 250 0.28 19 5.37 1343 2350 9.50 22324
Mooring LL 1.75 1000 1750 19.00 33250
Soil on Wall Dry EV 1.00 125 48.29 6036 6036 9.10 54930
Soil on Wall Submerged EV 1.00 65.5 129.07 8454 8454 8.78 74227
Active Soil Dry EH 0.90 125 0.28 5 3.53 442 398 15.67 6228
Active Soil Submerged EH 0.90 65.5 0.28 14 19.79 1296 1167 7.00 8166
Active Soil Submerged EH 0.90 65.5 0.28 14 27.70 1815 1633 4.67 7622
Height (Ft) 19.00 7297 23783 220492 106859
Toe (Ft) 2.50 tan φf 0.625 ∑FHorizontal ∑FVertical ∑MResisting ∑MOverturning
Heal (Ft) 11.50 C 0.9 RR = CV tan φf 13375
Foundation (Ft) 14.00 Foundation/3 4.67 σV 2489 e 2.22 b' 9.6
TYPE 3 SEGMENT - NORMAL TIDE
5.66
3.21
DC 150 pcf
35.06
DC 86 pcf
3.49
.0
.0
9.10
8.78
8.25
11.50
3.40
2.50 11.50
14.00
.0
.0
.6
WA 64 pcf
.5
.0
.6
.6
.0
125 pcf ka
EH
65.5 pcf ka
EH
65.5 pcf ka
EH
WA 64 pcf
250 psf ka
LS
.6
LS 250 psf
129.07
EV 65.5 pcf
3.25
TYPE 3 SEGMENT - NORMAL TIDE
48.29
Project St Thomas Veterans Drive Date 5/30/2023
Subject Wall Segment Design Check - Storm Event - Extreme 1 max Checked by RS/SWL
Date 9/25/2023
Filename = C:\Users\Lawsons\Desktop\Wall CADD Files\Veterans Drive St Thomas\Calculations\[Counterfort Wall Design and Bearing Resistance_RS_9-25-23.xlsx]Summary
COMPUTATION SHEET
Item Side Load Load
Factor γ
(pcf)
Ka φf=34° h
(Ft)
Volume
(CuFt)
Horizontal
Load
(Lb)
Factored
(Lb)
Vertical
Loads
(Lb)
Factored
(Lb)
Moment Arm
(Ft)
MResisting
(Ft Lb)
MOverturning
(Ft Lb)
Water Passive WA 1.00 64 10 3200 3200 3.33 10667
Water Active WA 1.00 64 19 11552 11552 6.33 73163
Wall Coping DC 1.25 150 8.25 1238 1547 3.49 5399
Wall Dry DC 1.25 150 8.04 1206 1508 3.62 5457
Wall Submerged DC 1.25 86 30.23 2600 3250 5.97 19401
LL on Wall LS 1.75 250 11.5 2875 5031.25 8.25 41508
LL Active LS 1.75 250 0.28 19 5.37 1343 2350 9.5 22324
Mooring 1.75
Soil on Wall Dry EV 1.35 125 89.46 11182 15096 8.95 135112
Soil on Wall Submerged EV 1.35 65.5 87.89 5757 7772 8.79 68317
Active Soil Dry EH 1.50 125 0.28 9 11.45 1431 2147 13.00 27908
Active Soil Submerged EH 1.50 65.5 0.28 10 25.44 1667 2500 5.00 12499
Active Soil Submerged EH 1.50 65.5 0.28 10 14.14 926 1389 3.33 4629
Height (Ft) 19.00 16737 34204 285860 140523
Toe (Ft) 2.50 tan φf 0.625 ∑FHorizontal ∑FVertical ∑MResisting ∑MOverturning
Heal (Ft) 11.50 C 0.9 RR = CV tan φf 19236
Foundation (Ft) 14.00 Foundation/3 4.67 σV 4025 e 2.75 b' 8.5
TYPE 3 SEGMENT - STORM EVENT
Project St Thomas Veterans Drive Date 5/30/2023
Subject Wall Segment Design Check - Storm Event - Extreme 1 min Checked by RS/SWL
Date 9/25/2023
Filename = C:\Users\Lawsons\Desktop\Wall CADD Files\Veterans Drive St Thomas\Calculations\[Counterfort Wall Design and Bearing Resistance_RS_9-25-23.xlsx]Summary
COMPUTATION SHEET
Item Side Load Load
Factor γ
(pcf)
Ka φf=34° h
(Ft)
Volume
(CuFt)
Horizontal
Load
(Lb)
Factored
(Lb)
Vertical
Loads
(Lb)
Factored
(Lb)
Moment Arm
(Ft)
MResisting
(Ft Lb)
MOverturning
(Ft Lb)
Water Passive WA 1.00 64 10 3200 3200 3.33 10667
Water Active WA 1.00 64 19 11552 11552 6.33 73163
Wall Coping DC 0.90 150 8.25 1238 1114 3.49 3887
Wall Dry DC 0.90 150 8.04 1206 1085 3.62 3929
Wall Submerged DC 0.90 86 30.23 2600 2340 5.97 13969
LL on Wall LS 1.75 250 11.5 2875 5031.25 8.25 41508
LL Active LS 1.75 250 0.28 19 5.37 1343 2350 9.5 22324
Mooring 1.75
Soil on Wall Dry EV 1.00 125 89.46 11182 11182 8.95 100083
Soil on Wall Submerged EV 1.00 65.5 87.89 5757 5757 8.79 50605
Active Soil Dry EH 0.90 125 0.28 9 11.45 1431 1288 13.00 16745
Active Soil Submerged EH 0.90 65.5 0.28 10 25.44 1667 1500 5.00 7499
Active Soil Submerged EH 0.90 65.5 0.28 10 14.14 926 833 3.33 2778
Height (Ft) 19.00 14323 26510 224648 122509
Toe (Ft) 2.50 tan φf 0.625 ∑FHorizontal ∑FVertical ∑MResisting ∑MOverturning
Heal (Ft) 11.50 C 0.9 RR = CV tan φf 14909
Foundation (Ft) 14.00 Foundation/3 4.67 σV 3440 e 3.15 b' 7.7
TYPE 3 SEGMENT - STORM EVENT
5.97
8.04
DC 150 pcf
30.23
DC 86 pcf
3.49
.0
.0
8.95
8.79
8.25
11.50
3.62
2.50 11.50
14.00
.0
.0
.3
WA 64 pcf
.5
.0
.3
.0
.0
125 pcf ka
EH
65.5 pcf ka
EH
65.5 pcf ka
EH
WA 64 pcf
250 psf ka
LS
.3
LS 250 psf
87.89
EV 65.5 pcf
3.25
TYPE 3 SEGMENT - STORM EVENT
24.1°
89.46
TYPE 4 SEGMENT
Project St Thomas Veterans Drive Date 5/30/2023
Subject Wall Segment Design Check - Normal Tide - Strenght 1 max Checked by RS/SWL
Date 9/25/2023
Filename = C:\Users\Lawsons\Desktop\Wall CADD Files\Veterans Drive St Thomas\Calculations\[Counterfort Wall Design and Bearing Resistance_RS_9-25-23.xlsx]Summary
COMPUTATION SHEET
Item Side Load Load
Factor γ
(pcf)
Ka φf=34° h
(Ft)
Volume
(CuFt)
Horizontal
Load
(Lb)
Factored
(Lb)
Vertical
Loads
(Lb)
Factored
(Lb)
Moment Arm
(Ft)
MResisting
(Ft Lb)
MOverturning
(Ft Lb)
Water Passive WA 1.00 64 17 9248 9248 5.67 52405
Water Active WA 1.00 64 17 9248 9248 5.67 52405
Wall Coping DC 1.25 150 8.25 1238 1547 3.99 6172
Wall Dry DC 1.25 150 3.21 482 602 3.90 2349
Wall Submerged DC 1.25 86 42.61 3664 4581 6.43 29453
LL on Wall LS 1.75 250 13 3250 5687.5 9.50 54031
LL Active LS 1.75 250 0.28 22 6.22 1555 2721 11.00 29931
Mooring LL 1.75 1000 1750 22.00 38500
Soil on Wall Dry EV 1.35 125 55.79 6974 9415 10.36 97535
Soil on Wall Submerged EV 1.35 65.5 182.14 11930 16106 10.05 161863
Active Soil Dry EH 1.50 125 0.28 5 3.53 442 663 18.67 12368
Active Soil Submerged EH 1.50 65.5 0.28 17 24.03 1574 2361 8.50 20068
Active Soil Submerged EH 1.50 65.5 0.28 17 40.85 2676 4014 5.67 22743
Height (Ft) 22.00 11508 37938 403808 176015
Toe (Ft) 3.00 tan φf 0.625 ∑FHorizontal ∑FVertical ∑MResisting ∑MOverturning
Heal (Ft) 13.00 C 0.9 RR = CV tan φf 21335
Foundation (Ft) 16.00 Foundation/3 5.33 σV 3159 e 2.00 b' 12.0
TYPE 4 SEGMENT - NORMAL TIDE
Project St Thomas Veterans Drive Date 5/30/2023
Subject Wall Segment Design Check - Normal Tide - Strength 1 min Checked by RS/SWL
Date 9/25/2023
Filename = C:\Users\Lawsons\Desktop\Wall CADD Files\Veterans Drive St Thomas\Calculations\[Counterfort Wall Design and Bearing Resistance_RS_9-25-23.xlsx]Summary
COMPUTATION SHEET
Item Side Load Load
Factor γ
(pcf)
Ka φf=34° h
(Ft)
Volume
(CuFt)
Horizontal
Load
(Lb)
Factored
(Lb)
Vertical
Loads
(Lb)
Factored
(Lb)
Moment Arm
(Ft)
MResisting
(Ft Lb)
MOverturning
(Ft Lb)
Water Passive WA 1.00 64 17 9248 9248 5.67 52405
Water Active WA 1.00 64 17 9248 9248 5.67 52405
Wall Coping DC 0.90 150 8.25 1238 1114 3.99 4444
Wall Dry DC 0.90 150 3.21 482 434 3.90 1691
Wall Submerged DC 0.90 86 42.61 3664 3298 6.43 21206
LL on Wall LS 1.75 250 13 3250 5687.5 9.50 54031
LL Active LS 1.75 250 0.28 22 6.22 1555 2721 11.00 29931
Mooring LL 1.75 1000 1750 22.00 38500
Soil on Wall Dry EV 1.00 125 55.79 6974 6974 10.36 72248
Soil on Wall Submerged EV 1.00 65.5 182.14 11930 11930 10.05 119898
Active Soil Dry EH 0.90 125 0.28 5 3.53 442 398 18.67 7421
Active Soil Submerged EH 0.90 65.5 0.28 17 24.03 1574 1417 8.50 12041
Active Soil Submerged EH 0.90 65.5 0.28 17 40.85 2676 2408 5.67 13646
Height (Ft) 22.00 8693 29437 325924 153944
Toe (Ft) 3.00 tan φf 0.625 ∑FHorizontal ∑FVertical ∑MResisting ∑MOverturning
Heal (Ft) 13.00 C 0.9 RR = CV tan φf 16555
Foundation (Ft) 16.00 Foundation/3 5.33 σV 2519 e 2.16 b' 11.7
TYPE 4 SEGMENT - NORMAL TIDE
6.43
3.21
DC 150 pcf
182.14
EV 65.5 pcf
42.61
DC 86 pcf
3.99
.0
.0
10.36
10.05
9.50
13.00
3.90
3.00 13.00
.0
.6
3.75
WA 64 pcf
16.00
LS 250 psf
.0
.0
.6
WA 64 pcf
.0
.6
.5
.6
250 psf ka
LS
125 pcf ka
EH
65.5 pcf ka
EH
65.5 pcf ka
EH
TYPE 4 SEGMENT - NORMAL TIDES
55.79
Project St Thomas Veterans Drive Date 5/30/2023
Subject Wall Segment Design Check - Storm Event - Extreme 1 max Checked by RS/SWL
Date 9/25/2023
Filename = C:\Users\Lawsons\Desktop\Wall CADD Files\Veterans Drive St Thomas\Calculations\[Counterfort Wall Design and Bearing Resistance_RS_9-25-23.xlsx]Summary
COMPUTATION SHEET
Item Side Load Load
Factor γ
(pcf)
Ka φf=34° h
(Ft)
Volume
(CuFt)
Horizontal
Load
(Lb)
Factored
(Lb)
Vertical
Loads
(Lb)
Factored
(Lb)
Moment Arm
(Ft)
MResisting
(Ft Lb)
MOverturning
(Ft Lb)
Water Passive WA 1.00 64 12 4608 4608 4.00 18432
Water Active WA 1.00 64 22 15488 15488 7.33 113579
Wall Coping DC 1.25 150 8.25 1238 1547 3.99 6172
Wall Dry DC 1.25 150 9.34 1402 1752 4.18 7324
Wall Submerged DC 1.25 86 36.48 3137 3921 6.79 26625
LL on Wall LS 1.75 250 13 3250 5687.5 9.50 54031
LL Active LS 1.75 250 0.28 22 6.22 1555 2721 11.00 29931
Mooring 1.75
Soil on Wall Dry EV 1.35 125 114.66 14332 19348 10.20 197351
Soil on Wall Submerged EV 1.35 65.5 123.27 8074 10901 10.06 109659
Active Soil Dry EH 1.50 125 0.28 10 14.14 1767 2650 15.33 40638
Active Soil Submerged EH 1.50 65.5 0.28 12 33.92 2222 3333 6.00 19998
Active Soil Submerged EH 1.50 65.5 0.28 12 20.35 1333 2000 4.00 7999
Height (Ft) 22.00 21584 43156 419594 212145
Toe (Ft) 3.00 tan φf 0.625 ∑FHorizontal ∑FVertical ∑MResisting ∑MOverturning
Heal (Ft) 13.00 C 0.9 RR = CV tan φf 24270
Foundation (Ft) 16.00 Foundation/3 5.33 σV 4489 e 3.19 b' 9.6
TYPE 4 SEGMENT - STORM EVENT
Project St Thomas Veterans Drive Date 5/30/2023
Subject Wall Segment Design Check - Storm Event - Extreme 1 min Checked by RS/SWL
Date 9/25/2023
Filename = C:\Users\Lawsons\Desktop\Wall CADD Files\Veterans Drive St Thomas\Calculations\[Counterfort Wall Design and Bearing Resistance_RS_9-25-23.xlsx]Summary
COMPUTATION SHEET
Item Side Load Load
Factor γ
(pcf)
Ka φf=34° h
(Ft)
Volume
(CuFt)
Horizontal
Load
(Lb)
Factored
(Lb)
Vertical
Loads
(Lb)
Factored
(Lb)
Moment Arm
(Ft)
MResisting
(Ft Lb)
MOverturning
(Ft Lb)
Water Passive WA 1.00 64 12 4608 4608 4.00 18432
Water Active WA 1.00 64 22 15488 15488 7.33 113579
Wall Coping DC 0.90 150 8.25 1238 1114 3.99 4444
Wall Dry DC 0.90 150 9.34 1402 1261 4.18 5273
Wall Submerged DC 0.90 86 36.48 3137 2823 6.79 19170
LL on Wall LS 1.75 250 13 3250 5687.5 9.50 54031
LL Active LS 1.75 250 0.28 22 6.22 1555 2721 11.00 29931
Mooring 1.75
Soil on Wall Dry EV 1.00 125 114.66 14332 14332 10.20 146186
Soil on Wall Submerged EV 1.00 65.5 123.27 8074 8074 10.06 81229
Active Soil Dry EH 0.90 125 0.28 10 14.14 1767 1590 15.33 24383
Active Soil Submerged EH 0.90 65.5 0.28 12 33.92 2222 2000 6.00 11999
Active Soil Submerged EH 0.90 65.5 0.28 12 20.35 1333 1200 4.00 4800
Height (Ft) 22.00 18391 33292 328765 184691
Toe (Ft) 3.00 tan φf 0.625 ∑FHorizontal ∑FVertical ∑MResisting ∑MOverturning
Heal (Ft) 13.00 C 0.9 RR = CV tan φf 18723
Foundation (Ft) 16.00 Foundation/3 5.33 σV 3847 e 3.67 b' 8.7
TYPE 4 SEGMENT - STORM EVENT
6.79
9.34
DC 150 pcf
123.27
EV 65.5 pcf
36.48
DC 86 pcf
3.99
.0
.0
10.20
10.06
9.50
13.00
4.18
3.00 13.00
.0
.0
.3
.3
.0
3.75
125 pcf ka
EH
65.5 pcf ka
EH
65.5 pcf ka
EH
WA 64 pcf
250 psf ka
LS
.0
16.00
LS 250 psf
.0
.0
.0
WA 64 pcf
TYPE 4 SEGMENT - STORM EVENT
24.44°
114.66
TYPE 5 SEGMENT
Project St Thomas Veterans Drive Date 5/30/2023
Subject Wall Segment Design Check - Normal Tide - Strenght 1 max Checked by RS/SWL
Date 9/25/2023
Filename = C:\Users\Lawsons\Desktop\Wall CADD Files\Veterans Drive St Thomas\Calculations\[Counterfort Wall Design and Bearing Resistance_RS_9-25-23.xlsx]Summary
COMPUTATION SHEET
Item Side Load Load
Factor γ
(pcf)
Ka φf=34° h
(Ft)
Volume
(CuFt)
Horizontal
Load
(Lb)
Factored
(Lb)
Vertical
Loads
(Lb)
Factored
(Lb)
Moment Arm
(Ft)
MResisting
(Ft Lb)
MOverturning
(Ft Lb)
Water Passive WA 1.00 64 20 12800 12800 6.67 85333
Water Active WA 1.00 64 20 12800 12800 6.67 85333
Wall Coping DC 1.25 150 8.25 1238 1547 4.49 6945
Wall Dry DC 1.25 150 3.21 482 602 4.40 2650
Wall Submerged DC 1.25 86 50.51 4344 5430 7.21 39149
LL on Wall LS 1.75 250 14.5 3625 6343.75 10.50 66609
LL Active LS 1.75 250 0.28 25 7.07 1767 3092 12.50 38650
Mooring LL 1.75 1000 1750 25.00 43750
Soil on Wall Dry EV 1.35 125 63.21 7901 10667 11.62 123947
Soil on Wall Submerged EV 1.35 65.5 243.87 15973 21564 11.32 244107
Active Soil Dry EH 1.50 125 0.28 5 3.53 442 663 21.67 14356
Active Soil Submerged EH 1.50 65.5 0.28 20 28.27 1852 2778 10.00 27775
Active Soil Submerged EH 1.50 65.5 0.28 20 56.54 3703 5555 6.67 37034
Height (Ft) 25.00 13837 46154 568741 246899
Toe (Ft) 3.50 tan φf 0.625 ∑FHorizontal ∑FVertical ∑MResisting ∑MOverturning
Heal (Ft) 14.50 C 0.9 RR = CV tan φf 25956
Foundation (Ft) 18.00 Foundation/3 6.00 σV 3309 e 2.03 b' 13.9
TYPE 5 SEGMENT - NORMAL TIDE
Project St Thomas Veterans Drive Date 5/30/2023
Subject Wall Segment Design Check - Normal Tide - Strength 1 min Checked by RS/SWL
Date 9/25/2023
Filename = C:\Users\Lawsons\Desktop\Wall CADD Files\Veterans Drive St Thomas\Calculations\[Counterfort Wall Design and Bearing Resistance_RS_9-25-23.xlsx]Summary
COMPUTATION SHEET
Item Side Load Load
Factor γ
(pcf)
Ka φf=34° h
(Ft)
Volume
(CuFt)
Horizontal
Load
(Lb)
Factored
(Lb)
Vertical
Loads
(Lb)
Factored
(Lb)
Moment Arm
(Ft)
MResisting
(Ft Lb)
MOverturning
(Ft Lb)
Water Passive WA 1.00 64 20 12800 12800 6.67 85333
Water Active WA 1.00 64 20 12800 12800 6.67 85333
Wall Coping DC 0.90 150 8.25 1238 1114 4.49 5001
Wall Dry DC 0.90 150 3.21 482 434 4.40 1908
Wall Submerged DC 0.90 86 50.51 4344 3909 7.21 28187
LL on Wall LS 1.75 250 14.5 3625 6343.75 10.50 66609
LL Active LS 1.75 250 0.28 25 7.07 1767 3092 12.50 38650
Mooring LL 1.75 1000 1750 25.00 43750
Soil on Wall Dry EV 1.00 125 63.21 7901 7901 11.62 91813
Soil on Wall Submerged EV 1.00 65.5 243.87 15973 15973 11.32 180820
Active Soil Dry EH 0.90 125 0.28 5 3.53 442 398 21.67 8614
Active Soil Submerged EH 0.90 65.5 0.28 20 28.27 1852 1667 10.00 16665
Active Soil Submerged EH 0.90 65.5 0.28 20 56.54 3703 3333 6.67 22220
Height (Ft) 25.00 10239 35675 459671 215233
Toe (Ft) 3.50 tan φf 0.625 ∑FHorizontal ∑FVertical ∑MResisting ∑MOverturning
Heal (Ft) 14.50 C 0.9 RR = CV tan φf 20063
Foundation (Ft) 18.00 Foundation/3 6.00 σV 2603 e 2.15 b' 13.7
TYPE 5 SEGMENT - NORMAL TIDE
7.21
3.21
DC 150 pcf
243.87
EV 65.5 pcf
50.51
DC 86 pcf
4.49
.0
.0
11.62
11.32
10.50
14.50
4.40
LS 250 psf
63.29
EV 125 pcf
4.25
WA 64 pcf
.6
.0
.0
.5
.0
.6
.6
.0
.6
250 psf ka
LS
125 pcf ka
EH
65.5 pcf ka
EH
65.5 pcf ka
EH
WA 64 pcf
TYPE 5 SEGMENT - NORMAL TIDES
3.50 14.50
Project St Thomas Veterans Drive Date 5/30/2023
Subject Wall Segment Design Check - Storm Event - Extreme 1 max Checked by RS/SWL
Date 9/25/2023
Filename = C:\Users\Lawsons\Desktop\Wall CADD Files\Veterans Drive St Thomas\Calculations\[Counterfort Wall Design and Bearing Resistance_RS_9-25-23.xlsx]Summary
COMPUTATION SHEET
Item Side Load Load
Factor γ
(pcf)
Ka φf=34° h
(Ft)
Volume
(CuFt)
Horizontal
Load
(Lb)
Factored
(Lb)
Vertical
Loads
(Lb)
Factored
(Lb)
Moment Arm
(Ft)
MResisting
(Ft Lb)
MOverturning
(Ft Lb)
Water Passive WA 1.00 64 15 7200 7200 5.00 36000
Water Active WA 1.00 64 25 20000 20000 8.33 166667
Wall Coping DC 1.25 150 8.25 1238 1547 4.49 6945
Wall Dry DC 1.25 150 9.34 1402 1752 4.68 8200
Wall Submerged DC 1.25 86 44.38 3816 4770 7.54 35969
LL on Wall LS 1.75 250 14.5 3625 6343.75 10.50 66609
LL Active LS 1.75 250 0.28 25 7.07 1767 3092 12.50 38650
Mooring 1.75
Soil on Wall Dry EV 1.35 125 129.66 16207 21879 11.45 250519
Soil on Wall Submerged EV 1.35 65.5 177.50 11626 15695 11.33 177828
Active Soil Dry EH 1.50 125 0.28 10 14.14 1767 2650 18.33 48589
Active Soil Submerged EH 1.50 65.5 0.28 15 42.41 2778 4166 7.50 31247
Active Soil Submerged EH 1.50 65.5 0.28 15 31.80 2083 3125 5.00 15624
Height (Ft) 25.00 25833 51988 582071 300777
Toe (Ft) 3.50 tan φf 0.625 ∑FHorizontal ∑FVertical ∑MResisting ∑MOverturning
Heal (Ft) 14.50 C 0.9 RR = CV tan φf 29237
Foundation (Ft) 18.00 Foundation/3 6.00 σV 4804 e 3.59 b' 10.8
TYPE 5 SEGMENT - STORM EVENT
Project St Thomas Veterans Drive Date 5/30/2023
Subject Wall Segment Design Check - Storm Event - Extreme 1 min Checked by RS/SWL
Date 9/25/2023
Filename = C:\Users\Lawsons\Desktop\Wall CADD Files\Veterans Drive St Thomas\Calculations\[Counterfort Wall Design and Bearing Resistance_RS_9-25-23.xlsx]Summary
COMPUTATION SHEET
Item Side Load Load
Factor γ
(pcf)
Ka φf=34° h
(Ft)
Volume
(CuFt)
Horizontal
Load
(Lb)
Factored
(Lb)
Vertical
Loads
(Lb)
Factored
(Lb)
Moment Arm
(Ft)
MResisting
(Ft Lb)
MOverturning
(Ft Lb)
Water Passive WA 1.00 64 15 7200 7200 5.00 36000
Water Active WA 1.00 64 25 20000 20000 8.33 166667
Wall Coping DC 0.90 150 8.25 1238 1114 4.49 5001
Wall Dry DC 0.90 150 9.34 1402 1261 4.68 5904
Wall Submerged DC 0.90 86 44.38 3816 3435 7.54 25898
LL on Wall LS 1.75 250 14.5 3625 6343.75 10.50 66609
LL Active LS 1.75 250 0.28 25 7.07 1767 3092 12.50 38650
Mooring 1.75
Soil on Wall Dry EV 1.00 125 129.66 16207 16207 11.45 185570
Soil on Wall Submerged EV 1.00 65.5 177.50 11626 11626 11.33 131725
Active Soil Dry EH 0.90 125 0.28 10 14.14 1767 1590 18.33 29153
Active Soil Submerged EH 0.90 65.5 0.28 15 42.41 2778 2500 7.50 18748
Active Soil Submerged EH 0.90 65.5 0.28 15 31.80 2083 1875 5.00 9374
Height (Ft) 25.00 21857 39987 456706 262593
Toe (Ft) 3.50 tan φf 0.625 ∑FHorizontal ∑FVertical ∑MResisting ∑MOverturning
Heal (Ft) 14.50 C 0.9 RR = CV tan φf 22488
Foundation (Ft) 18.00 Foundation/3 6.00 σV 4119 e 4.15 b' 9.7
7.54
9.34
DC 150 pcf
177.50
EV 65.5 pcf
44.38
DC 86 pcf
4.49
.0
.0
11.45
11.33
10.50
14.50
4.68
3.50 10.25 4.25
LS 250 psf
129.66
EV 125 pcf
4.25
WA 64 pcf
.0
.0
.0
.5
.0
.3
.3
.5
.0
250 psf ka
LS
125 pcf ka
EH
65.5 pcf ka
EH
65.5 pcf ka
EH
WA 64 pcf
24.7°
TYPE 6 SEGMENT
Project St Thomas Veterans Drive Date 5/30/2023
Subject Wall Segment Design Check - Normal Tide - Strenght 1 max Checked by RS/SWL
Date 9/25/2023
Filename = C:\Users\Lawsons\Desktop\Wall CADD Files\Veterans Drive St Thomas\Calculations\[Counterfort Wall Design and Bearing Resistance_RS_9-25-23.xlsx]Summary
COMPUTATION SHEET
Item Side Load Load
Factor γ
(pcf)
Ka φf=34° h
(Ft)
Volume
(CuFt)
Horizontal
Load
(Lb)
Factored
(Lb)
Vertical
Loads
(Lb)
Factored
(Lb)
Moment Arm
(Ft)
MResisting
(Ft Lb)
MOverturning
(Ft Lb)
Water Passive WA 1.00 64 23 16928 16928 7.67 129781
Water Active WA 1.00 64 23 16928 16928 7.67 129781
Wall Coping DC 1.25 150 8.25 1238 1547 4.99 7719
Wall Dry DC 1.25 150 3.21 482 602 4.90 2951
Wall Submerged DC 1.25 86 58.76 5053 6316 7.99 50469
LL on Wall LS 1.75 250 16 4000 7000 12.00 84000
LL Active LS 1.75 250 0.28 28 7.92 1979 3463 14.00 48483
Mooring LL 1.75 1000 1750 28.00 49000
Soil on Wall Dry EV 1.35 125 70.79 8848 11945 12.87 153737
Soil on Wall Submerged EV 1.35 65.5 314.24 20583 27787 12.60 350115
Active Soil Dry EH 1.50 125 0.28 5 3.53 442 663 24.67 16344
Active Soil Submerged EH 1.50 65.5 0.28 23 32.51 2129 3194 11.50 36733
Active Soil Submerged EH 1.50 65.5 0.28 23 74.77 4898 7347 7.67 56324
Height (Ft) 28.00 16416 55198 778772 336664
Toe (Ft) 4.00 tan φf 0.625 ∑FHorizontal ∑FVertical ∑MResisting ∑MOverturning
Heal (Ft) 16.00 C 0.9 RR = CV tan φf 31042
Foundation (Ft) 20.00 Foundation/3 6.67 σV 3446 e 1.99 b' 16.0
TYPE 6 SEGMENT - NORMAL TIDE
Project St Thomas Veterans Drive Date 5/30/2023
Subject Wall Segment Design Check - Normal Tide - Strength 1 min Checked by RS/SWL
Date 9/25/2023
Filename = C:\Users\Lawsons\Desktop\Wall CADD Files\Veterans Drive St Thomas\Calculations\[Counterfort Wall Design and Bearing Resistance_RS_9-25-23.xlsx]Summary
COMPUTATION SHEET
Item Side Load Load
Factor γ
(pcf)
Ka φf=34° h
(Ft)
Volume
(CuFt)
Horizontal
Load
(Lb)
Factored
(Lb)
Vertical
Loads
(Lb)
Factored
(Lb)
Moment Arm
(Ft)
MResisting
(Ft Lb)
MOverturning
(Ft Lb)
Water Passive WA 1.00 64 23 16928 16928 7.67 129781
Water Active WA 1.00 64 23 16928 16928 7.67 129781
Wall Coping DC 0.90 150 8.25 1238 1114 4.99 5558
Wall Dry DC 0.90 150 3.21 482 434 4.90 2125
Wall Submerged DC 0.90 86 58.76 5053 4548 7.99 36337
LL on Wall LS 1.75 250 16 4000 7000 12.00 84000
LL Active LS 1.75 250 0.28 28 7.92 1979 3463 14.00 48483
Mooring LL 1.75 1000 1750 28.00 49000
Soil on Wall Dry EV 1.00 125 70.79 8848 8848 12.87 113879
Soil on Wall Submerged EV 1.00 65.5…