Q and A 2.20.25.pdf
PDF 80 KB Posted
- Attached to
- FIBER REINFORCED CONCRETE ASPHALT TESTING SERVICES Federal contract opportunity
- Solicitation number
- 693C7325Q000011
About this file
This is a Questions and Answers document for solicitation 693C7325Q000011 for Fiber Reinforced Concrete Asphalt Testing Services issued by the Federal Highway Administration. The document addresses three main topics through two Q&A exchanges.
The first Q&A clarifies that while AASHTO R 18 accreditation is preferred, laboratories without formal accreditation can provide alternative documentation demonstrating equipment calibration and technician proficiency. Acceptable alternatives include calibration reports, technician bios showing proficiency, or completion of high ratings on proficiency samples. The second Q&A provides guidance on quote submissions, indicating there is no strict page limit but recommending 1-5 pages that clearly address each SOW task. Quotes can be submitted in Excel or Word format, with value-added suggestions priced separately. The only qualification requirement is demonstrating R 18 compliance for testing. All bidders must complete an 889 form, with additional information requested upon award.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Q and A 3.3.25.pdf | ||
| RFQ NO. 693C7325Q000011.pdf | ||
| PROVISION 52.204-24.pdf | ||
| PROVISION 52.204-26.pdf | ||
| Statement of Work Fiber Study.pdf | ||
| Sec 889 Offeror Representation Form.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
HFLECO250053PR - 693C7325Q00011 QSheet1
Q&A
Q1.
I wanted to confirm whether AASHTO accreditation for specific test methods is the intended requirement. I would like to inquire if there is flexibility in this requirement for laboratories that have demonstrated expertise in conducting the required tests but do not hold formal AASHTO accreditation. The lab I am considering for this project has extensive experience performing these tests as part of various research projects, including those funded by national and state agencies. While not AASHTO-accredited, they have successfully executed similar test programs that required high precision and quality control. Would it be possible to submit documentation demonstrating the lab's qualifications, past work, and quality assurance measures in lieu of formal accreditation?
A1.
The intent is to request AASHTO R 18 accreditation for tests that offer accreditation. AASHTO R 18 accreditation ensures equipment is properly calibrated and technicians are proficient by audit and proficiency samples among several other quality initiatives, but Equipment and Proficiency is the focus here. The equipment shown in the proposal must show calibration if AASHTO R 18 is not available and evidence such as a calibration report can be considered equivalent in this study. Technician proficiency must be shown in either an AASHTO R 18 competency requirement style, or a bio demonstrating proficiency, or completion of high ratings of proficiency samples in which independent assurance/independent study samples with calculated ratings can be used. Assurance that end results are reliable is the intent of requesting accreditation and any evidence as further described above can be considered to meet the criteria.
Q2.
1- Is there a specific word or page limit for the quote submission?
2- Are there any specific requirements to highlight the qualifications of the core team and subcontractors (e.g., CVs, past project examples, letters of intent, lab facility information, etc.) and show project timeline or a quad chart?
3- Should subcontractors complete the attached representation form/provisions as part of the submission?
HFLECO250053PR - 693C7325Q00011 QSheet1
A2.
1- For the submission or quote there is no limit criteria. However, as an example the expectation would be about 1-5 pages that is clear and brief enough to cover the agreement you would like to make. Explicitly spell out how the service can meet each task on the SOW. An excel or word format may be used. The SOW may be copied with your responses after each bullet if it’s easier. Additionally, and separately, Any value added suggestions not covered in the SOW should be briefly described and priced separately.
2- The only qualification requirement is demonstrating that R 18 requirements are being met for testing purposes if it is not simply accredited. No other requirements are in the SOW. Previous experience will be taken into consideration as long as it is best value to government and meets all required needs.
3- All bidders should complete an 889 form. When the award goes out, additional information will be requested.