This notice is a pre-solicitation for a firm fixed-price construction contract to be awarded by the Department of Transportation Federal Highway Administration. The project consists of pavement preservation along approximately 53 miles of the Blue Ridge Parkway in Virginia, including thin asphalt overlay or chip seal overlay with fog seal. Work will also include asphalt patching and pavement markings. The project budget is between $1-5 million and must be completed by December 2020. Bids are due in November 2019. Offerors must demonstrate experience with thin overlay or chip seal preservation methods. The contract will be split into multiple schedules. Annual representations and certifications must be completed on SAM.gov and Vets-4212 on dol.gov. Firms must register in SAM for payment. Subcontracting plans are required for businesses over $700,000 or $1.5 million for construction and must be approved prior to award.
View the file
Other files
Show all 26
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STRUCTURE NO. 5140 133P
BLUFF MOUNTAIN TUNNEL INSPECTION DATE: 11/2/16
STRUCTURE SUMMARY
TUNNEL IDENTIFICATION AND DESCRIPTION
LINING MATERIAL: ............... CONCRETE MINIMUM VERTICAL CLR: .... 13.6 FT (4.1 M)
SPRINGLINE LENGTH: ........ 29.2 FT (8.9 M) STRUCT. TOTAL LENGTH: ... 630.0 FT (192.0 M)
CURB TO CURB WIDTH: ..... 29.2 FT (8.9 M) YEAR BUILT:
PROJ./PLAN REF. NO: ......... 1F10,1G2 / NONE YEAR RECONSTRUCTED:
NPS ROAD CLASS:
1 - PRINCIPAL PARK ROAD
STRUCTURE HISTORY:
LOCATION
BLUE RIDGE PARKWAY MILE POINT: ..................... 53.01 (KM PT 85.31)
STATE: .................................. VIRGINIA LOCATION: 7.4 MILES TO U.S. ROUTE 60
FACILITY CARRIED: ............. BLUE RIDGE PARKWAY
FEATURE INTERSECTED: ... BLUFF MOUNTAIN
STRUCTURE EVALUATION SUMMARY
This concrete lined tunnel is in good to fair condition overall. The main problem is the deterioration of the concrete lining which has areas of delamination and exposed rebar in several locations. Other problems include missing vertical clearance signs from both approaches, a lack of Type 3 reflective object markers at the corners of both portals, several missing reflectors along the tunel, and minor deterioration of mortar joints in the northwest retaining wall.
Corrective action should be taken as outlined in this report to prevent the possible development of more serious or costly problems in the future.
INSPECTION TEAM: R. SILVESTRY, L. ELLIS
CONDITION ASSESSMENT:
REINALDO SILVESTRY, FIELD TEAM LEADER 703-404-6251
REPORT REVIEW:
MARCUS MILLER, P.E., BRIDGE INSPECTION ENGINEER 703-404-6252
REPORT APPROVAL: DATE: 3/31/17
JORGOMAI CEESAY, PH.D., P.E., BIP SUPERVISORY ENGINEER 703-404-6244
RECOMMENDATIONS AND ESTIMATED COSTS STRUCTURE NO. 5140 133P
226 PRIORITY OF IMPROVEMENT D
A (Critical) - Structure is closed, in imminent danger of collapse, or presents a critical safety hazard.
B (Major) - Structure exhibits severe deterioration, presents a safety hazard, or is designated a high priority due to age and/or condition.
C (Moderate) - Structure is deficient, functionally obsolete, or requires substantial repairs to prevent a serious deficiency or unsafe condition.
D (Minor) - Structure is generally in good condition. Preventative maintenance may be required.
E (Special) - Structure is under construction or reconstruction.
ITEM
NO.
MAINTENANCE RECOMMENDATIONS
(GENERALLY NOT FLHP ELIGIBLE)
QTY. UNIT COST
UNIT
ESTIMATE
COST
PRELIM.
222.7 INSTALL VERTICAL CLEARANCE SIGNS AT APPROACHES. REPLACE BROKEN
REFLECTIVE DELINEATOR AS NECESSARY. INSTALL TYPE 3 REFLECTIVE OBJECT
MARKERS AT CORNERS OF PORTAL.
1 LS
PRELIM. MAINTENANCE TOTAL : $3,000
ITEM
REHABILITATION/RECONSTRUCTION
QTY. UNIT
UNIT
COST ESTIMATES
PRELIM. COST
NO (TYPICALLY NEEDED WITHIN 5 YEARS)
REHAB. RECONSTR.
59.1 REMOVE UNSOUND CONCRETE FROM TUNNEL LINING, CLEAN
REBAR, AND PLACE NEW CONCRETE TO ORIGINAL DIMENSIONS.
1 LS
223.1 CLEAN AND REPOINT RETAINING WALL MASONRY MORTAR JOINTS
AS NECESSARY.
1 LS
CONTRACT COSTS FOR MOBILIZATION, TRAFFIC CONTROL, AND
DESIGN CONSTRUCTION ENGINEERING (70% TOTAL REHAB COST)
PLUS PARK LOCATION FACTOR.
1 LS
PRELIM. REHABILITATION/RECONSTRUCTION TOTAL :
PRELIMINARY ESTIMATE TOTAL* :
(*Includes typical contract costs for mobilization, traffic control, and design/construction engineering; but does not include detour bridges, work beyond the bridge limits, or work not listed above. Estimates are approximate and are for preliminary planning purposes only; they should not be used as a complete or final engineers estimate.)
REMARKS: Cost estimates assume that recommended actions will be combined with similar work being performed on other structures.
FIELD INSPECTION REPORT STRUCTURE NO. 5140 133P
CONDITION RATING CODES FOR ITEMS 58 - 62, 222, 223
N
NOT APPLICABLE
EXCELLENT CONDITION
VERY GOOD CONDITION - no problems noted.
GOOD CONDITION - some minor problems.
SATISFACTORY CONDITION - structural elements show some minor deterioration.
FAIR CONDITION - all primary structural elements are sound but may have minor section loss, cracking, spalling, or scour.
POOR CONDITION - advanced section loss, deterioration, spalling, or scour.
SERIOUS CONDITION - loss of section, deterioration, spalling, or scour have seriously affected primary structural components. Local failures are possible.
Fatigue cracks in steel or shear cracks in concrete may be present.
CRITICAL CONDITION - advanced deterioration of primary structural elements. Fatigue cracks in steel or shear cracks in concrete may be present or scour may have removed substructure support. Unless closely monitored it may be necessary to close the structure until corrective action can be taken.
“IMMINENT” FAILURE CONDITION - major deterioration or section loss present in critical structural components or obvious vertical or horizontal movement affecting structure stability. Structure is closed to traffic but corrective action may return structure to light service.
FAILED CONDITION - out of service; beyond corrective action.
CONDITION RATING CODE EQUIVALENTS FOR SUB-ELEMENTS
G = GOOD (CODES 7 - 9) F = FAIR (CODES 5 - 6) P = POOR (CODES 0 - 4)
59. TUNNEL 6
F1. LINING
G PORTALS2.
NCURBS AND SIDEWALKS3.
G 4. DRAINS AND DRAINAGE
G 5. WEARING SURFACE
G 6. RIDEABILITY
N 7. LIGHTING
G 8. OTHER (PAVED WATERWAYS)
9. ADEQUACY OF OPENING INSUFF
222. APPROACHES 7
N 1. APPROACH SLABS
N 2. RELIEF JOINTS
N 3. APPROACH GUARDRAIL
G 4. SURFACING
G 5. EROSION
G 6. SETTLEMENT
P 7. SIGNS
G 8. ALIGNMENT
N 9. OTHER
223. RETAINING WALL 7
G 1. WALL
N 2. WEEP HOLES
N 3. FOUNDATION
G 4. EROSION AND/OR SCOUR
G 5. SETTLEMENT OR DEFLECTION
N 6. OTHER
36. TRAFFIC AND SAFETY FEATURES
NA. BRIDGE RAILINGS
NB. TRANSITIONS
N C. APPROACH GUARDRAILS
N D. APPROACH GUARDRAIL ENDS
TRAFFIC SAFETY RATING CODES
N
Does not meet standards or a safety feature is required and none is provided.
Meets currently acceptable standards.
Not applicable or a safety feature is not required.
ITEM REFERENCE AND REMARKS
59.1 MODERATE LONGITUDINAL AND TRANSVERSE CRACKING WITH
MODERATE EFFLORESCENCE WITHIN 10' OF BOTH PORTALS. .
MINOR TO MODERATE TRANSVERSE CRACKING WITH
EFFLORESCENCE THROUGHOUT TUNNEL LINING WITH RUST
STAINS IN SEVERAL LOCATIONS; ISOLATED LONGITUDINAL AND
RANDOM CRACKING ALONG LENGTH OF CROWN. EXPOSED REBAR
IN SEVERAL LOCATIONS DUE TO INSUFFICIENT CONCRETE COVER.
MINOR SPALLED AREAS AND NUMEROUS PATCHES THROUGHOUT.
59.2, 222.4 MINOR CRACKING WITH EFFLORESCENCE ON RING STONES AND
PORTAL MASONRY MORTAR JOINTS. MINOR VEGETATION GROWTH
ON SOUTH PORTAL. EFFLORESCENCE ON SOUTH APPROACH
ROADWAY FROM RING STONES.
59.8 MINOR DEBRIS ACCUMULATION IN PAVED WATERWAYS OVER TOP
OF BOTH PORTALS.
222.7 NO VERTICAL CLEARANCE SIGNS AT APPROACHES. TYPE 3
REFLECTIVE OBJECT MARKERS MISSING AT CORNERS OF PORTAL.
SEVERAL MISSING AND BROKEN REFLECTORS THROUGHOUT THE
TUNNEL
"TUNNEL", "TURN ON LIGHTS", AND "CHECK LIGHTS" SIGNS AT
APPROACHES.
GEOLOGICAL SURVEY MARKER ON WEST SIDE OF SOUTH PORTAL.
"BLUFF MOUNTAIN TUNNEL" SIGN AT BOTH APPROACHES.
223.1 RETAINING WALL AT NORTHWEST CORNER OF STRUCTURE; MINOR
CRACKING AND ISOLATED DETERIORATION OF MASONRY MORTAR
JOINTS WITH VEGETATION GROWTH IN JOINTS.
STRUCTURE INVENTORY AND APPRAISAL STRUCTURE NO. 5140 133P
STRUCTURE IDENTIFICATION
(201) PARK: BLUE RIDGE PARKWAY
(202) STRUCTURE NAME:
(203) STRUCTURE KIND:
(204) STRUCTURE NUMBER:
(205) NPS REGION:
(206) ROUTE CODE NUMBER: ...
(207) ROAD SECTION NO:
(208) NPS ROAD CLASS:
(209) WITHIN NPS BNDRY?:
(210) OPERATING UNIT:
(211) PROJECT NO(S):
(212) DRAWING NUMBERS:
(21) MAINTAINED BY:
(22) OWNER:
BLUFF MOUNTAIN TUNNEL
3 - TUNNEL
5140-133P
4 - SOUTHEAST
133P
1 - PRINCIPAL PARK ROAD
YES
JAMES R.
1F10,1G2
NONE
66 - NATIONAL PARK SERVICE
66 - NATIONAL PARK SERVICE
(1) STATE:
(2) STATE HWY. AGENCY DIST:
(3) COUNTY CODE:
(4) CITY/PLACE CODE:
(5) INVENTORY ROUTE:
(6) FEATURES INTERSECTED:
(7) FACILITY CARRIED:
(8) STATE STRUCTURE NO:
(9) LOCATION:
(10) INV. RTE. - MIN. VERT. CLR: ..
(11) MILE POINT:
(27) YEAR BUILT:
(106) YEAR RECONSTRUCTED:
(20) TOLL:
(37) HISTORICAL DESIGNATION: ..
513 - VIRGINIA (VA)
009 - AMHERST
261000010
BLUFF MOUNTAIN
BLUE RIDGE PARKWAY
5140133P0000000
7.4 MILES TO U.S. ROUTE 6
13.83 FT (4.22 M)
53.01 (KM PT 85.31)
3 - FREE ROAD
5 - NOT ELIGIBLE
STRUCTURE DESCRIPTION, FOUNDATION, AND DECK TYPE
(43A) MAIN STR. MATERIAL: ..
(43B) MAIN STR. TYPE:
(45) NO. OF MAIN SPANS:
(48) MAX. SPAN LENGTH:
(49) STRUCTURE LENGTH:
(216A) ABUTMENT #1 FDN:
(216B) ABUTMENT #2 FDN:
(217A) PREDOM. PIER FDN.: ..
(217B) SECOND. PIER FDN: ...
(107) DECK TYPE:
1 - CONCRETE
18 - TUNNEL
29.2 FT (8.9 M)
630.0 FT (192.0 M)
6 - N/A
6 - N/A
6 - N/A
6 - N/A
N - NOT APPLICABLE
(44A) APPR. STR. MATERIAL: ........ 0 - OTHER
(44B) APPR. STR. TYPE: ................ 00 - OTHER
(46) NO. OF APPROACH SPANS: .. 0
(108) WEAR SURFACE/PROTECT SYSTEM:
A) TYPE WEARING SURFACE: .. N - NOT APPLICABLE
B) TYPE MEMBRANE: ................. 0 - NONE
C) TYPE PROTECTION:
0 - NONE
NO(218) IS SALT USED?:
LOAD RATING AND POSTING
(31) DESIGN LOAD:
0 - UNKNOWN (41) LOAD RESTRICTION:
A - OPEN, NO RESTRICTION
(66) INVENTORY RATING: ...... 0.0 TONS (0.0 METRIC TONS) (70) BRIDGE POSTING: .............. 5 - NO POSTING REQUIRED
(64) OPERATING RATING: ...... 0.0 TONS (0.0 METRIC TONS)
INSPECTION DATES
(90) INSPECTION DATE: 11/16 (91) FREQ. OF INSP: 48 MONTHS (92 / 93) CRITICAL FEATURE INSPECTION (CFI):
(219) ADD. STUDIES NEEDED: N - 0 - NONE (A) FRACTURE CRITICAL: ... NO
INSP. EVERY: MONTHS - LAST INSP. : (220) SPECIAL STUDY TYPE: 0 - NONE
(B) UNDERWATER: .............. NO
(221) SPECIAL STUDY DATE:
INSP. EVERY: MONTHS - LAST INSP. :
(C) SPECIAL INSPECTION: .. NO
INSP. EVERY: MONTHS - LAST INSP. :
STRUCTURE INVENTORY AND APPRAISAL STRUCTURE NO. 5140 133P
GEOMETRY, TRAFFIC, AND NAVIGATIONAL DATA
(16) LATITUDE: ............................. 37°39'56.20" (51) CURB TO CURB WIDTH: ........... 29.2 FT (8.9 M)
(17) LONGITUDE: ......................... 79°19'19.10" (52) DECK WIDTH: ............................ 0.0 FT (0.0 M)
(19) DETOUR LENGTH: ............... 25 MI (40 KM) (32) APPR. ROADWAY WIDTH: ........ 38.0 FT (11.6 M)
(28A) LANES ON STRUCT: .......... 00 (213) APPR. PAVEMENT WIDTH: ..... 22.0 FT (6.7 M)
(28B) LANES UNDER STRUCT: ... 02 LEFT SHOULDER: .................. 8.0 FT (2.4 M)
(42A) SERVICE ON: ..................... 1 - HIGHWAY RIGHT SHOULDER: ................ 8.0 FT (2.4 M)
(42B) SERVICE UNDER: .............. 0 - OTHER (33) BRIDGE MEDIAN: ....................... 0 - NO MEDIAN
(29) AVG. DAILY TRAFFIC: .......... 474 (34) SKEW ANGLE: ............................ 0 °
(30) YEAR OF ADT: ...................... 2012 (35) DECK FLARE?: ........................... NO
(114) FUTURE ADT: ..................... 521 (47) TOTAL HORIZ. CLEARANCE: .... 29.2 FT (8.9 M)
(115) YEAR OF FUTURE ADT: ..... 2032 (50) SIDEWALKS:
(101) PARALLEL STRUCTURE: ... N - NONE LEFT : ...................................... 0.0 FT (0.0 M)
(38) NAVIGATION CONTROL?: ... N RIGHT : ................................... 0.0 FT (0.0 M)
(39) VERTICAL CLEARANCE: ...... 0.0 FT (0.0 M) (214) BRIDGE RAIL TYPE:
(40) HORIZ. CLEARANCE: ........... 0.0 FT (0.0 M) RAIL CONFIGURATION: ......... 0 - N/A
(111) ABUT. OR PIER PROT: ....... MATERIAL: .............................. 0 - N/A
DESIGN TYPE: ........................ 0 - N/A
LATERAL UNDERCLEARANCE:
(55) RIGHT: ....................... 3.4 FT (1.0 M) (215) BRIDGE RAIL HEIGHT: ............ 0.00 FT (0.00 M)
(56) LEFT: ......................... 0.0 FT (0.0 M) (53) MIN. VRT. CLEAR. OVER DECK: 13.58 FT (4.14 M)
(54) MIN. VRT. UNDERCLEARANCE: 99.99 FT (99.99 M)
CONDITION AND APPRAISAL DATA, PROPOSED IMPROVEMENTS, AND COST
(58) DECK: .................................N
(59) SUPERSTRUCTURE: .........N
(60) SUBSTRUCTURE: ..............N
(61) CHANNEL: ..........................N
(62) CULVERT: ........................... N
(222) APPROACHES:
(223) RETAINING WALL:
(36) TRAFFIC SAFETY FEAT: ... NNNN
(75A) TYPE OF WORK:
(75B) WORK DONE BY:
(76) IMPROVEMENT LENGTH: ..
(67) STRUCTURAL EVALUATION:
(68) DECK GEOMETRY:
(69) UNDERCLEARANCES:
(71) WATERWAY ADEQUACY:
(72) APPROACH ALIGNMENT:
(113) SCOUR CRITICAL:
(225) PURPOSE OF IMPROVEMENT:
(226) PRIORITY OF IMPROVEMENT:
(227) MAINTENANCE COST:
(228) REHAB./RECONSTR. COST: ...
(229) CONSTRUCTION COST:
N
N - Not over waterway.
2 - REHAB/RECONSTRUCTION
D - MINOR
ADDITIONAL INFORMATION
(230) STRUCTURE HISTORY:
(231) ADDITIONAL CONSIDERATIONS:
(330) ADDITIONAL CONFIG. INFO.:
http:79�19'19.10 http:37�39'56.20
APPENDIX STRUCTURE NO. 5140 133P
PHOTOGRAPHS STRUCTURE NO. 5140 133P
PHOTO #1 - NORTH PORTAL
PHOTO #2 - SOUTH PORTAL
PHOTO #3 - GENERAL ROADWAY VIEW LOOKING NORTH (PHOTO FROM
10/15/2012 INSPECTION REPORT)
PHOTO #4 - GENERAL VIEW OF SOUTH TUNNEL CROWN LOOKING
NORTH, NOTE CRACKING WITH EFFLORESCENCE AND
EFFLORESCENCE FROM RINGSTONES
PHOTO #5 - HORIZONTAL AND DIAGONAL CRACKING 30' FROM SOUTH
END IN WEST LINING
PHOTO #6 - TYPICAL TRANSVERSE CRACKING WITH EFFLORESCENCE
AND RUST STAINING ON TUNNEL CROWN, CROWN OF LINING
APPROXIMATELY 100' FROM NORTH PORTAL SHOWN
PHOTO #7 - TYPICAL CRACKING AND WATER
LEAKAGE SURROUNDING AND THROUGHOUT
PATCHWORK; 40' FROM SOUTH PORTAL, EAST
LINING
PHOTO #8 - SPALLING WITH EXPOSED REBAR
ON CROWN 60' FROM SOUTH PORTAL
PHOTO #9 - CRACKING AND EFFLORESCENCE THROUGHOUT
PATCHWORK IN CROWN 125' FROM SOUTH PORTAL
PHOTO #10 - SPALLING AND EXPOSED REBAR ADJACENT TO
PATCHWORK, 370' FROM SOUTH PORTAL, EAST LINING
PHOTO #11 - EXPOSED REBAR WITH CORROSION IN PATCHWORK IN
CROWN; 390' FROM SOUTH PORTAL
PHOTO #12 - WIDESPREAD CRACKING AND EFFLORESCENCE WITH
RUST STAINING ON WEST LINING AND CROWN ABOUT 165' FROM
NORTH PORTAL
STRUCTURE NO. 5140 133PPHOTOGRAPHS
PHOTO #13 - PATCHWORK IN CROWN 30' FROM NORTH PORTAL; NOTE
CRACKING AND EFFLORESCENCE IN AND ADJACENT TO PATCHWORK
PHOTO #14 - CRACKING WITH EFFLORESCENCE SURROUNDING AND
THROUGHOUT PATCHWORK IN CROWN 85' FROM NORTH PORTAL
PHOTO #15 - TYPICAL TRANSVERSE AND VERTICAL CRACKING WITH
EFFLORESCENCE AND RUST STAINING ON WEST WALL,
APPROXIMATELY 410' FROM SOUTH PORTAL
PHOTO #16 - TYPICAL VERTICAL CRACKING WITH EFFLORESCENCE
FROM ROADWAY TO CROWN, APPROXIMATELY 160' FROM SOUTH
PORTAL, WEST LINING WITH EFFLORESCENCE
PHOTO #17 - EXPOSED REBAR ON CROWN OF
TUNNEL LINING, APPROXIMATELY 80 FEET
FROM SOUTH PORTAL
PHOTO #18 - TYPICAL LONGITUDINAL AND
TRANSVERSE CRACKING WITH
EFFLORESCENCE WITHIN 10' OF PORTALS,
WEST SIDE AT NORTH PORTAL SHOWN; NOTE
EFFLORESCENCE ON UNDERSIDE OF
RINGSTONES
PHOTO #19 - TYPICAL CRACKING WITH EFFLORESCENCE ON RING
STONES AND PORTAL MASONRY MORTAR JOINTS, SOUTH PORTAL
SHOWN (PHOTO FROM 10/15/2012 INSPECTION REPORT)
PHOTO #20 - TYPICAL CRACKING AND DETERIORATION OF
NORTHWEST RETAINING WALL MASONRY MORTAR JOINTS WITH
VEGETATION GROWTH IN JOINTS (PHOTO FROM 10/15/2012
STRUCTURE NO. 5140 133P
PHOTO #21 - MASONRY WALLS ON WEST SIDE
OF NORTH PORTAL
PHOTO #22 - TYPICAL DETERIORATION OF
MASONRY MORTAR JOINTS IN NORTHEAST
WINGWALL
PHOTOGRAPHS
PHOTO #23 - TYPICAL DETERIORATION OF MASONRY MORTAR JOINT
IN SOUTHWEST WINGWALL; NOTE WATER STAINING AND
EFFLORESCENCE BUILD-UP ALONG WALL