5140-013P4250_Redacted.pdf

PDF 4 MB Posted

Attached to
Blue Ridge Parkway Pavement Preservation FY19
Solicitation number
693C73-20-R-000002
Issued by

About this file

This document provides details for a federal contract opportunity to perform pavement preservation work on the Blue Ridge Parkway. The solicitation is for proposals to complete pavement preservation of approximately 53.40 miles of roadway between Milepost 0.0 and 27.2, 37.5 and 45.3, and 46.1 and 64.5. Work will include one of two pavement preservation treatment methods, asphalt overlay or chip seal overlay with fog seal, as well as asphalt patching, pavement markings, and miscellaneous tasks. Proposals are due in November 2019, with construction to be finished by December 2020. The contract is valued between $1-5 million and will be awarded by the Department of Transportation Federal Highway Administration. Offerors must demonstrate experience with the pavement preservation treatment methods.

View the file

Other files

File Type Posted
Amendment 0001 - NP BLRI PVT PRES FY19.pdf PDF
5140-008P1594_Redacted.pdf PDF
5140-012P6375_Redacted.pdf PDF
VETS-4212 Form.pdf PDF
Plans - NP-BLRI PVT PRES FY19.pdf PDF
5140-007P1821_Redacted.pdf PDF
5140-133P4250_Redacted.pdf PDF
5140-015P2550_Redacted.pdf PDF
NEPA_CE.pdf PDF
5140-198P1594_Redacted.pdf PDF
RFP Solicitation NP-BLRI PVT PRES FY19(1).pdf PDF
5140-014P3188_Redacted.pdf PDF
5140-001P12750_Redacted.pdf PDF
5140-011P12750_Redacted.pdf PDF
5140-009P1417_Redacted.pdf PDF
5140-016P2125_Redacted.pdf PDF
ADV_Subcontracting Plan (Blank).doc DOC document
FP14_Eng.pdf PDF
ADV_Offeror's Qualifications Form.doc DOC document
5140-006P2125_Redacted.pdf PDF
5140-204T3188_Redacted.pdf PDF
5140-010P1275_Redacted.pdf PDF
5140-160P212_Redacted.pdf PDF
Road Inventory Program Report.pdf PDF
5140-205P2550_Redacted.pdf PDF
Synopsis_-_NP-BLRI_PVT_PRES_FY19.doc DOC document
Show all 26

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STRUCTURE NO. 5140 013P

OTTER CREEK CULVERT #7 INSPECTION DATE: 11/1/16

STRUCTURE SUMMARY

CULVERT IDENTIFICATION AND DESCRIPTION

MAIN SPAN MATERIAL: ........ CONCRETE CONTINUOUS NO. OF BARRELS:

FOUNDATION: ....................... SPREAD FTG ON BEARING MAT'L

BARREL LENGTH: ............... 84 FT (26 M)

STRUCT. TOTAL LENGTH: ... 43.0 FT (13.1 M) SKEW ANGLE: ..................... 6 °

MAX. SPAN LENGTH: ............ 20.0 FT (6.1 M) 1957

YEAR BUILT:

PROJ./PLAN REF. NO: .......... 1G5-10 / 3007

YEAR RECONSTRUCTED: .. N/A

NPS ROAD CLASS: ............... 1 - PRINCIPAL PARK ROAD

STRUCTURE HISTORY: ....... 2009-RAILING SYSTEM INSTALLED.

LOCATION

BLUE RIDGE PARKWAY MILE POINT: ..................... 61.33 (KM PT 98.70)

STATE: .................................. VIRGINIA LOCATION: 0.8 MILES TO VISITORS CENTER

FACILITY CARRIED: ............. BLUE RIDGE PARKWAY

FEATURE INTERSECTED: ... OTTER CREEK

STRUCTURE EVALUATION SUMMARY

This two barrel concrete box culvert is in fair condition overall. Problems include deterioration of the masonry mortar joints throughout the structure with random cracked masonry stones in the north end wall, and moderate vertical cracking of the concrete section of the intermediate wall. Additional problems include heavy vegetation growth along the top of both headwalls and minor spalling with exposed rebar on the slab underside in the south barrel.

The north barrel is blocked by an accumulation of silt and stacked stones which conforms to the surrounding topography; the stream therefore flows along the south end wall.

Corrective measures should be taken as outlined in this report to help prevent the possible development of more serious or costly problems in the future.

INSPECTION TEAM: R. SILVESTRY, L. ELLIS

CONDITION ASSESSMENT:

REINALDO SILVESTRY, FIELD TEAM LEADER 703-404-6251

REPORT REVIEW:

MARCUS MILLER, P.E., BRIDGE INSPECTION ENGINEER 703-404-6252

REPORT APPROVAL: DATE: 3/31/17

JORGOMAI CEESAY, PH.D., P.E., BIP SUPERVISORY ENGINEER 703-404-6244

RECOMMENDATIONS AND ESTIMATED COSTS STRUCTURE NO. 5140 013P

226 PRIORITY OF IMPROVEMENT D

A (Critical) - Structure is closed, in imminent danger of collapse, or presents a critical safety hazard.

B (Major) - Structure exhibits severe deterioration, presents a safety hazard, or is designated a high priority due to age and/or condition.

C (Moderate) - Structure is deficient, functionally obsolete, or requires substantial repairs to prevent a serious deficiency or unsafe condition.

D (Minor) - Structure is generally in good condition. Preventative maintenance may be required.

E (Special) - Structure is under construction or reconstruction.

ITEM

NO.

MAINTENANCE RECOMMENDATIONS

(GENERALLY NOT FLHP ELIGIBLE)

QTY. UNIT COST

UNIT

ESTIMATE

COST

PRELIM.

62.3 REMOVE VEGETATION GROWING ALONG TOP OF HEADWALLS. 1 LS

PRELIM. MAINTENANCE TOTAL :

ITEM

NO.

REHABILITATION/RECONSTRUCTION

(TYPICALLY NEEDED WITHIN 5 YEARS)

QTY. UNIT

UNIT

COST ESTIMATES

PRELIM. COST

REHAB. RECONSTR.

61.4, 62.1 REPOINT MASONRY MORTAR JOINTS IN BARREL WALLS AND

WINGWALLS AS NECESSARY.

1 LS

61.1 REDIRECT CHANNEL AWAY FROM SOUTH WALL WITH ENGINEERED

RIPRAP.

1 LS

62.1 EPOXY INJECT OR SEAL CRACKING OF CONCRETE PORTION OF

INTERMEDIATE WALL.

1 LS

62.1 CLEAN EXPOSED REBAR ON SLAB UNDERSIDE AND COAT WITH

APPROVED PROTECTIVE SEALANT.

1 LS

62.10 SEAL CRACKS ON WEARING SURFACE 1 LS

CONTRACT COSTS FOR MOBILIZATION, TRAFFIC CONTROL, AND

DESIGN CONSTRUCTION ENGINEERING (70% TOTAL REHAB COST)

PLUS PARK LOCATION FACTOR.

1 LS

PRELIM. REHABILITATION/RECONSTRUCTION TOTAL :

PRELIMINARY ESTIMATE TOTAL* :

(*Includes typical contract costs for mobilization, traffic control, and design/construction engineering; but does not include detour bridges, work beyond the bridge limits, or work not listed above. Estimates are approximate and are for preliminary planning purposes only; they should not be used as a complete or final engineers estimate.)

REMARKS: Cost estimates assume that recommended actions will be combined with similar work being performed on other structures.

FIELD INSPECTION REPORT STRUCTURE NO. 5140 013P

CONDITION RATING CODES FOR ITEMS 58 - 62, 222, 223

N

NOT APPLICABLE

EXCELLENT CONDITION

VERY GOOD CONDITION - no problems noted.

GOOD CONDITION - some minor problems.

SATISFACTORY CONDITION - structural elements show some minor deterioration.

FAIR CONDITION - all primary structural elements are sound but may have minor section loss, cracking, spalling, or scour.

POOR CONDITION - advanced section loss, deterioration, spalling, or scour.

SERIOUS CONDITION - loss of section, deterioration, spalling, or scour have seriously affected primary structural components. Local failures are possible.

Fatigue cracks in steel or shear cracks in concrete may be present.

CRITICAL CONDITION - advanced deterioration of primary structural elements. Fatigue cracks in steel or shear cracks in concrete may be present or scour may have removed substructure support. Unless closely monitored it may be necessary to close the structure until corrective action can be taken.

“IMMINENT” FAILURE CONDITION - major deterioration or section loss present in critical structural components or obvious vertical or horizontal movement affecting structure stability. Structure is closed to traffic but corrective action may return structure to light service.

FAILED CONDITION - out of service; beyond corrective action.

CONDITION RATING CODE EQUIVALENTS FOR SUB-ELEMENTS

G = GOOD (CODES 7 - 9) F = FAIR (CODES 5 - 6) P = POOR (CODES 0 - 4)

61. CHANNEL 5

F ALIGNMENT1.

G EROSION AND/OR SCOUR2.

N 3. CHANNEL PROTECTION

P4. WATERWAY OBSTRUCTIONS

N 5. OTHER

6. ADEQUACY OF OPENING SUFF

NORMAL VELOCITY MED 7.

11 FT. AVG. CLEAR OPENING 8.

ITEM REFERENCE AND REMARKS

9. STREAM BED COMPOSITION :

STONES, SAND

62. CUL VERT 6

PARAPETS AND/OR RAILINGS 9.

ADEQUACY OF COVER 8.

SETTLEMENT AND/OR DEFLECTION 7.

EROSION AND/OR SCOUR 6.

5. DEBRIS AND/OR SILT

4. WINGWALLS

3. HEADWALLS

2. FOOTINGS

1. BARREL(S)

ROADWAY SURFACE10.

11. RIDEABILITY

12. OTHER

F

N

G

F

F

G

F

G

G

G

G

N

222. APPROACHES 7

OTHER9.

8. ALIGNMENT

SIGNS 7.

6. SETTLEMENT

EROSION5.

SURFACING4.

APPROACH GUARDRAIL3.

RELIEF JOINTS 2.

APPROACH SLABS1. N

N

G

G

G

G

N

G

N

223. RETAINING WALL N

6. OTHER

5. SETTLEMENT OR DEFLECTION

4. EROSION AND/OR SCOUR

3. FOUNDATION

2. WEEP HOLES

1. WALL

36. TRAFFIC AND SAFETY FEATURES

C. APPROACH GUARDRAILS

B. TRANSITIONS

A. BRIDGE RAILINGS

D. APPROACH GUARDRAIL ENDS

N

TRAFFIC SAFETY RATING CODES

0 - Does not meet standards or a safety feature is required and none is provided.

1 - Meets currently acceptable standards.

N - Not applicable or a safety feature is not required. 3 OF 17

61.1,4, 62.5 CHANNEL FLOWS AGAINST SOUTH BARREL WALL. SILT AND STONE

ACCUMULATION BLOCKS FLOW THROUGH NORTH BARREL

(CONFORMS TO SURROUNDING TOPOGRAPHY).

HEAVY DEBRIS (CUT TREES) ALONG SOUTHEAST WINGWALL.

62.1,7 MODERATE TRANSVERSE CRACKING WITH EFFLORESCENCE AND

LEAKAGE ON SLAB UNDERSIDE, PRIMARILY IN SOUTH BARREL.

MINOR LEAKAGE AND EFFLORESCENCE ALONG CONSTRUCTION

JOINTS. SEVERAL MINOR SPALLS WITH EXPOSED REBAR DUE TO

INSUFFICIENT CONCRETE COVER ON SLAB UNDERSIDE IN SOUTH

BARREL.

MODERATE CRACKING AND DETERIORATION OF BARREL WALL

MASONRY MORTAR JOINTS. MINOR EFFLORESCENCE ON MASONRY

WALLS AT JOINT WITH CONCRETE SLAB. MODERATE VERTICAL

CRACKING, UP TO 1/4"W, ON BOTH FACES OF CONCRETE PORTION

OF INTERMEDIATE WALL NEAR CONSTRUCTION JOINT IN TOP SLAB.

TWO CRACKED MASONRY STONES AT EAST SIDE OF NORTH END

WALL; ONE AT WEST SIDE.

62.3 MINOR EFFLORESCENCE FROM MASONRY HEADWALLS AND RING

STONES. NUMEROUS SMALL TREES AND HEAVY VEGETATION ON

TOP OF HEADWALLS.

62.4 MODERATE CRACKING OF WINGWALL MASONRY MORTAR JOINTS;

MINOR EFFLORESCENCE FROM JOINTS IN SOME LOCATIONS.

62.6 SEVERE (UP TO 4.3') UNDERMINING OF CONCRETE APRON AT

UPSTREAM SIDE OF SOUTH BARREL WALL; VOID (10"D) BETWEEN

APRON AND BASE OF WALL. APRON APPEARS TO ONLY BE

CONCRETE OVERRUN FROM CONSTRUCTION AND SERVES NO

PURPOSE TO STRUCTURE.

FIELD INSPECTION REPORT STRUCTURE NO. 5140 013P

ADDITIONAL ITEM REFERENCE AND REMARKS

62.9, 222.3 MINOR CHECKING OF STEEL-BACKED TIMBER RAILS AND RAIL POSTS.

BACKING PLATES.

MINOR RUSTING OF TIMBER RAIL STEEL

62.10, 222.4 MINOR LONGITUDINAL AND MAP CRACKING OF PAVEMENT.

36.D RAIL ENDS NOT TERMINATED SAFELY.

STRUCTURE NO. 5140 013P

INSPECTION DATE: 11/1/16

TRUCK TYPE

TONS

INVENTORY RATING (NORMAL TRAFFIC)

METRIC TONS METRIC TONSTONS

OPERATING RATING (MAXIMUM LOAD)

H

HS

TYPE 3

TYPE 3S2

TYPE 3-3

DESIGN LOADING:

DATE OF LOAD RATING CALCULATION:

LOAD RATING CONTROLLED BY:

REMARKS:

CAPACITY MEETS OR EXCEEDS DESIGN LOAD

CAPACITY IS LESS THAN DESIGN LOAD

ORIGINAL LOAD RATING CALCULATION APPLICABLE

ORIGINAL LOAD RATING CALCULATION REVISED

TOP SLAB

8/15

X

X

STRUCTURE LOAD RATING

OTTER CREEK CULVERT #7

H15 (M13.5)

STRUCTURE INVENTORY AND APPRAISAL STRUCTURE NO. 5140 013P

STRUCTURE IDENTIFICATION

(201) PARK: BLUE RIDGE PARKWAY (1) STATE: ....................................... 513 - VIRGINIA (VA)

(202) STRUCTURE NAME: .......... OTTER CREEK CULVERT #7 (2) STATE HWY. AGENCY DIST:

(203) STRUCTURE KIND: ............2 - CULVERT (3) COUNTY CODE: ........................ 009 - AMHERST

(4) CITY/PLACE CODE:

(204) STRUCTURE NUMBER: ..... 5140-013P

(205) NPS REGION: .................... 4 - SOUTHEAST (5) INVENTORY ROUTE:

(206) ROUTE CODE NUMBER: ... 1 (6) FEATURES INTERSECTED:....... OTTER CREEK

(207) ROAD SECTION NO: ..........013P (7) FACILITY CARRIED: .................. BLUE RIDGE PARKWAY

(208) NPS ROAD CLASS: ............ 1 - PRINCIPAL PARK ROAD (8) STATE STRUCTURE NO: .......... 5140013P0000000

(209) WITHIN NPS BNDRY?: ....... YES (9) LOCATION: ................................ 0.8 MILES TO VISITORS CEN

(210) OPERATING UNIT: ............. JAMES R. (10) INV. RTE. - MIN. VERT. CLR: .. 99.99 FT (99.99 M)

(211) PROJECT NO(S): ................ 1G5-10 (11) MILE POINT: ............................. 61.33 (KM PT 98.70)

(212) DRAWING NUMBERS: ....... 3007 (27) YEAR BUILT:

(21) MAINTAINED BY: ................. 66 - NATIONAL PARK SERVICE (106) YEAR RECONSTRUCTED: .... N/A

(22) OWNER: ............................... 66 - NATIONAL PARK SERVICE (20) TOLL: ........................................ 3 - FREE ROAD

(37) HISTORICAL DESIGNATION: .. 5 - NOT ELIGIBLE

STRUCTURE DESCRIPTION, FOUNDATION, AND DECK TYPE

(43A) MAIN STR. MATERIAL: ..

(43B) MAIN STR. TYPE:

(45) NO. OF MAIN SPANS:

(48) MAX. SPAN LENGTH:

(49) STRUCTURE LENGTH:

(216A) ABUTMENT #1 FDN:

(216B) ABUTMENT #2 FDN:

(217A) PREDOM. PIER FDN.: ..

(217B) SECOND. PIER FDN: ...

(107) DECK TYPE:

2 - CONCRETE CONTINUOUS

19 - CULVERT

20.0 FT (6.1 M)

43.0 FT (13.1 M)

2 - SPREAD FTG ON BEARING MAT'L

2 - SPREAD FTG ON BEARING MAT'L

2 - SPREAD FTG ON BEARING MAT'L

2 - SPREAD FTG ON BEARING MAT'L

N - NOT APPLICABLE

(44A) APPR. STR. MATERIAL: ........ 0 - OTHER

(44B) APPR. STR. TYPE: ................ 00 - OTHER

(46) NO. OF APPROACH SPANS: .. 0

(108) WEAR SURFACE/PROTECT SYSTEM:

A) TYPE WEARING SURFACE: .. N - NOT APPLICABLE

B) TYPE MEMBRANE: ................. N - NOT APPLICABLE

C) TYPE PROTECTION:

N - NOT APPLICABLE

YES(218) IS SALT USED?:

LOAD RATING AND POSTING

(31) DESIGN LOAD:

2 - H15 (M13.5) (41) LOAD RESTRICTION:

R - POSTED (OTHER)

(66) INVENTORY RATING: ...... 99.9 TONS (99.9 METRIC TONS) (70) BRIDGE POSTING: .............. 5 - NO POSTING REQUIRED

(64) OPERATING RATING: ...... 99.9 TONS (99.9 METRIC TONS)

INSPECTION DATES

(90) INSPECTION DATE: 11/16 (91) FREQ. OF INSP: 24 MONTHS (92 / 93) CRITICAL FEATURE INSPECTION (CFI):

(219) ADD. STUDIES NEEDED: N - 0 - NONE (A) FRACTURE CRITICAL: ... NO

INSP. EVERY: MONTHS - LAST INSP. : (220) SPECIAL STUDY TYPE: 0 - NONE

(B) UNDERWATER: .............. NO

(221) SPECIAL STUDY DATE:

INSP. EVERY: MONTHS - LAST INSP. :

(C) SPECIAL INSPECTION: .. NO

INSP. EVERY: MONTHS - LAST INSP. :

STRUCTURE INVENTORY AND APPRAISAL STRUCTURE NO. 5140 013P

GEOMETRY, TRAFFIC, AND NAVIGATIONAL DATA

(16) LATITUDE: ............................. 37°34'24.30" (51) CURB TO CURB WIDTH: ........... 30.5 FT (9.3 M)

(17) LONGITUDE: ......................... 79°20'58.10" (52) DECK WIDTH: ............................ 0.0 FT (0.0 M)

(19) DETOUR LENGTH: ............... 23 MI (37 KM) (32) APPR. ROADWAY WIDTH: ........ 30.0 FT (9.1 M)

(28A) LANES ON STRUCT: .......... 02 (213) APPR. PAVEMENT WIDTH: ..... 22.0 FT (6.7 M)

(28B) LANES UNDER STRUCT: ... 00 LEFT SHOULDER: .................. 4.0 FT (1.2 M)

(42A) SERVICE ON: ..................... 1 - HIGHWAY RIGHT SHOULDER: ................ 4.0 FT (1.2 M)

(42B) SERVICE UNDER: .............. 5 - WATERWAY (33) BRIDGE MEDIAN: ....................... 0 - NO MEDIAN

(29) AVG. DAILY TRAFFIC: .......... 474 (34) SKEW ANGLE: ............................ 6 °

(30) YEAR OF ADT: ...................... 2012 (35) DECK FLARE?: ........................... NO

(114) FUTURE ADT: ..................... 521 (47) TOTAL HORIZ. CLEARANCE: .... 30.5 FT (9.3 M)

(115) YEAR OF FUTURE ADT: ..... 2032 (50) SIDEWALKS:

(101) PARALLEL STRUCTURE: ... N - NONE LEFT : ...................................... 0.0 FT (0.0 M)

(38) NAVIGATION CONTROL?: ... 0 RIGHT : ................................... 0.0 FT (0.0 M)

(39) VERTICAL CLEARANCE: ...... 0.0 FT (0.0 M) (214) BRIDGE RAIL TYPE:

(40) HORIZ. CLEARANCE: ........... 0.0 FT (0.0 M) RAIL CONFIGURATION: ......... 1 - FULL HEIGHT (NO PARAPE

(111) ABUT. OR PIER PROT: ....... MATERIAL: .............................. 8 - TIMBER/OTHER

DESIGN TYPE: ........................ 3 - SIMPLE RAIL (joints at each

LATERAL UNDERCLEARANCE:

(55) RIGHT: ....................... 0.0 FT (0.0 M) (215) BRIDGE RAIL HEIGHT: ............ 2.33 FT (0.71 M)

(56) LEFT: ......................... 0.0 FT (0.0 M) (53) MIN. VRT. CLEAR. OVER DECK: 99.99 FT (99.99 M)

(54) MIN. VRT. UNDERCLEARANCE: 0.00 FT (0.00 M)

CONDITION AND APPRAISAL DATA, PROPOSED IMPROVEMENTS, AND COST

(58) DECK: .................................N

(59) SUPERSTRUCTURE: .........N

(60) SUBSTRUCTURE: ..............N

(61) CHANNEL:

(62) CULVERT:

(222) APPROACHES:

(223) RETAINING WALL: ........... N

(36) TRAFFIC SAFETY FEAT: ... 1N10

(75A) TYPE OF WORK:

(75B) WORK DONE BY:

(76) IMPROVEMENT LENGTH: ..

(67) STRUCTURAL EVALUATION:

(68) DECK GEOMETRY:

(69) UNDERCLEARANCES:

(71) WATERWAY ADEQUACY:

(72) APPROACH ALIGNMENT:

(113) SCOUR CRITICAL:

(225) PURPOSE OF IMPROVEMENT:

(226) PRIORITY OF IMPROVEMENT:

(227) MAINTENANCE COST:

(228) REHAB./RECONSTR. COST: ...

(229) CONSTRUCTION COST:

N

8 - Stable; scour above top of fo

2 - REHAB/RECONSTRUCTION

D - MINOR

ADDITIONAL INFORMATION

(230) STRUCTURE HISTORY:

2009-RAILING SYSTEM INSTALLED.

(231) ADDITIONAL CONSIDERATIONS:

(330) ADDITIONAL CONFIG. INFO.:

CULVERT LENGTH = 85'.

http:79�20'58.10 http:37�34'24.30

APPENDIX STRUCTURE NO. 5140 013P

PHOTOGRAPHS STRUCTURE NO. 5140 013P

FLOW

PHOTO #1 - LOOKING SOUTHBOUND TOWARD ROANOKE

PHOTO #2 - WEST (UPSTREAM) SIDE

PHOTO #3 - GENERAL TOP SIDE VIEW LOOKING SOUTH

PHOTO #4 - TYPICAL LONGITUDINAL AND TRANSVERSE CRACKING OF

PAVEMENT THROUGHOUT NORTHBOUND & SOUTHBOUND LANES;

NOTE ALSO DETERIORATION OF SAFETY EDGE OF PAVEMENT

STRUCTURE NO. 5140 013PPHOTOGRAPHS

STRUCTURE NO. 5140 013P

PHOTO #5 - TYPICAL CHECKING OF

STEEL-BACKED TIMBER RAILS AND RAIL

POSTS; WEST RAILING SHOWN

PHOTO #6 - GENERAL UNDERSIDE VIEW OF

BARREL #2 LOOKING WEST

PHOTOGRAPHS

PHOTO #7 - TYPICAL EFFLORESCENCE FROM

RING STONES; EAST HEADWALL OVER

BARREL #1

OTTER CREEK CULVERT #7 INSPECTION DATE: 11/1/16

STRUCTURE NO. 5140 013P

PHOTO #8 - SPALLING WITH EXPOSED REBAR

DUE TO INSUFFICIENT COVER ON SLAB

UNDERSIDE AT EAST END OF SOUTH BARREL

PHOTO #9 - TYPICAL TRANSVERSE CRACKING

WITH EFFLORESCENCE AND LEAKAGE ON

SLAB UNDERSIDE AT EAST END OF BARREL #1

SHOWN

OTTER CREEK CULVERT #7 INSPECTION DATE: 11/1/16

STRUCTURE NO. 5140 013P

PHOTO #10 - GENERAL VIEW OF NORTH

BARREL WALL; NOTE ALSO ACCUMULATED

SEDIMENT ALONG BARREL

PHOTO #11 - TYPICAL CRACKING AND

DETERIORATION OF BARREL END WALL

MASONRY MORTAR JOINTS; NORTH BARREL

WALL NEAR WEST END SHOWN

OTTER CREEK CULVERT #7 INSPECTION DATE: 11/1/16

STRUCTURE NO. 5140 013P

PHOTO #12 - VERTICAL CRACKING SEEN ON

BOTH FACES OF CONCRETE PORTION OF

INTERMEDIATE WALL NEAR CONSTRUCTION

JOINT IN TOP SLAB; NORTH SIDE SHOWN

PHOTO #13 - TYPICAL CRACKING OF

WINGWALL MASONRY MORTAR JOINTS WITH

EFFLORESCENCE; NORTHEAST WINGWALL

SHOWN

OTTER CREEK CULVERT #7 INSPECTION DATE: 11/1/16

STRUCTURE NO. 5140 013P

PHOTO #14 - UNDERMINED CONCRETE APRON

AT UPSTREAM END OF BARREL #2 END WALL

WITH A VOID BETWEEN APRON AND BASE OF

END WALL

STRUCTURE NO. 5140 013P

PHOTO #15 - CLOSE-UP OF VOID DEPTH AT

BASE OF SOUTH END WALLS AND TOP OF

APRON SLAB

PHOTO #16 - DEBRIS ALONG SOUTHEAST

WINGWALL; NOTE EROSION ADJACENT TO

WINGWALL BASE

PHOTOGRAPHS STRUCTURE NO. 5140 013P

PHOTO #17 - LOOKING UPSTREAM

PHOTO #18 - LOOKING DOWNSTREAM THROUGH SOUTH BARREL

(PHOTO FROM 10/29/2014 INSPECTION REPORT)

File details come from the government source that posted it. Updated .