5140-007P1821_Redacted.pdf

PDF 4 MB Posted

Attached to
Blue Ridge Parkway Pavement Preservation FY19
Solicitation number
693C73-20-R-000002
Issued by

About this file

This document summarizes a federal contract opportunity for pavement preservation work on the Blue Ridge Parkway. The solicitation seeks proposals for resurfacing approximately 53 miles of roadway across five counties in Virginia, using either a thin asphalt overlay or chip seal method. Offerors must demonstrate experience with the proposed pavement preservation treatment. The contract value is estimated between $1-5 million and work must be completed by December 2020. The solicitation will be issued on November 18, 2019 with proposals due as specified in the SF1442. Interested vendors must register on FBO.gov for updates and plan holders lists will not be maintained. Subcontracting plans are required for contracts over $700,000. The work is to be awarded and administered by the US Department of Transportation Federal Highway Administration Eastern Federal Lands office.

View the file

Other files

File Type Posted
Amendment 0001 - NP BLRI PVT PRES FY19.pdf PDF
5140-008P1594_Redacted.pdf PDF
5140-012P6375_Redacted.pdf PDF
VETS-4212 Form.pdf PDF
Plans - NP-BLRI PVT PRES FY19.pdf PDF
5140-133P4250_Redacted.pdf PDF
5140-015P2550_Redacted.pdf PDF
NEPA_CE.pdf PDF
5140-198P1594_Redacted.pdf PDF
RFP Solicitation NP-BLRI PVT PRES FY19(1).pdf PDF
5140-014P3188_Redacted.pdf PDF
5140-001P12750_Redacted.pdf PDF
5140-011P12750_Redacted.pdf PDF
5140-013P4250_Redacted.pdf PDF
5140-009P1417_Redacted.pdf PDF
5140-016P2125_Redacted.pdf PDF
ADV_Subcontracting Plan (Blank).doc DOC document
FP14_Eng.pdf PDF
ADV_Offeror's Qualifications Form.doc DOC document
5140-006P2125_Redacted.pdf PDF
5140-204T3188_Redacted.pdf PDF
5140-010P1275_Redacted.pdf PDF
5140-160P212_Redacted.pdf PDF
Road Inventory Program Report.pdf PDF
5140-205P2550_Redacted.pdf PDF
Synopsis_-_NP-BLRI_PVT_PRES_FY19.doc DOC document
Show all 26

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STRUCTURE NO. 5140 007P

OTTER CREEK CULVERT #1 INSPECTION DATE: 11/2/16

STRUCTURE SUMMARY

CULVERT IDENTIFICATION AND DESCRIPTION

MAIN SPAN MATERIAL: ........ CONCRETE CONTINUOUS NO. OF BARRELS:

FOUNDATION: ....................... SPREAD FTG ON BEARING MAT'L

BARREL LENGTH: ............... 50 FT (15 M)

STRUCT. TOTAL LENGTH: ... 43.7 FT (13.3 M) SKEW ANGLE: ..................... 30 °

MAX. SPAN LENGTH: ............ 20.5 FT (6.2 M) 1957

YEAR BUILT:

PROJ./PLAN REF. NO: .......... 1G2 / 3000

YEAR RECONSTRUCTED: .. N/A

NPS ROAD CLASS: ............... 1 - PRINCIPAL PARK ROAD

STRUCTURE HISTORY: ....... 1984-JOINT REPAIR.

LOCATION

BLUE RIDGE PARKWAY MILE POINT: ..................... 56.58 (KM PT 91.05)

STATE: .................................. VIRGINIA LOCATION: 4.9 MILES TO VA ROUTE 130

FACILITY CARRIED: ............. BLUE RIDGE PARKWAY

FEATURE INTERSECTED: ... OTTER CREEK

STRUCTURE EVALUATION SUMMARY

This two barrel concrete box culvert is in fair condition overall. Problems include accumulation of silt, stones, and drift in the north barrel; minor to moderate deterioration of the barrel wall, headwall, and wingwall masonry mortar joints;

and several fallen trees in the channels. The stream flows through the south barrel due to the accumulation in the north barrel and the severe skew of the channel with the structure resulting in minor scour that exposes the length of the footing. The scour will continue to be monitored during subsequent inspections.

Corrective measures should be taken as outlined in this report to help prevent the possible development of more serious or costly problems in the future. In addition, consideration should be given to installing a guardrail system over the structure to help improve motorist safety.

INSPECTION TEAM: R. SILVESTRY, L. ELLIS

CONDITION ASSESSMENT:

REINALDO SILVESTRY, FIELD TEAM LEADER 703-404-6251

REPORT REVIEW:

MARCUS MILLER, P.E., BRIDGE INSPECTION ENGINEER 703-404-6252

REPORT APPROVAL: DATE: 3/31/17

JORGOMAI CEESAY, PH.D., P.E., BIP SUPERVISORY ENGINEER 703-404-6244

RECOMMENDATIONS AND ESTIMATED COSTS STRUCTURE NO. 5140 007P

226 PRIORITY OF IMPROVEMENT D

A (Critical) - Structure is closed, in imminent danger of collapse, or presents a critical safety hazard.

B (Major) - Structure exhibits severe deterioration, presents a safety hazard, or is designated a high priority due to age and/or condition.

C (Moderate) - Structure is deficient, functionally obsolete, or requires substantial repairs to prevent a serious deficiency or unsafe condition.

D (Minor) - Structure is generally in good condition. Preventative maintenance may be required.

E (Special) - Structure is under construction or reconstruction.

ITEM

NO.

MAINTENANCE RECOMMENDATIONS

(GENERALLY NOT FLHP ELIGIBLE)

QTY. UNIT COST

UNIT

ESTIMATE

COST

PRELIM.

62.5 REMOVE SILT, STONE, AND DRIFT ACCUMULATION FROM BOTH BARRELS. 1 LS

61.4 REMOVE FALLEN TREES FROM CHANNEL. 1 LS

PRELIM. MAINTENANCE TOTAL :

ITEM

REHABILITATION/RECONSTRUCTION

QTY. UNIT

UNIT

COST ESTIMATES

PRELIM. COST

NO (TYPICALLY NEEDED WITHIN 5 YEARS)

REHAB. RECONSTR.

62.9, 222.3 INSTALL GUARDRAIL SYSTEM OVER STRUCTURE AND AT

APPROACHES.

1 LS

62.1,3,4 CLEAN AND REPOINT BARREL WALL, HEADWALL, AND WINGWALL

MASONRY MORTAR JOINTS AS NECESSARY.

1 LS

CONTRACT COSTS FOR MOBILIZATION, TRAFFIC CONTROL, AND

DESIGN CONSTRUCTION ENGINEERING (70% TOTAL REHAB COST)

PLUS PARK LOCATION FACTOR.

1 LS

PRELIM. REHABILITATION/RECONSTRUCTION TOTAL :

PRELIMINARY ESTIMATE TOTAL* :

(*Includes typical contract costs for mobilization, traffic control, and design/construction engineering; but does not include detour bridges, work beyond the bridge limits, or work not listed above. Estimates are approximate and are for preliminary planning purposes only; they should not be used as a complete or final engineers estimate.)

REMARKS: Cost estimates assume that recommended actions will be combined with similar work being performed on other structures.

FIELD INSPECTION REPORT STRUCTURE NO. 5140 007P

CONDITION RATING CODES FOR ITEMS 58 - 62, 222, 223

N

NOT APPLICABLE

EXCELLENT CONDITION

VERY GOOD CONDITION - no problems noted.

GOOD CONDITION - some minor problems.

SATISFACTORY CONDITION - structural elements show some minor deterioration.

FAIR CONDITION - all primary structural elements are sound but may have minor section loss, cracking, spalling, or scour.

POOR CONDITION - advanced section loss, deterioration, spalling, or scour.

SERIOUS CONDITION - loss of section, deterioration, spalling, or scour have seriously affected primary structural components. Local failures are possible.

Fatigue cracks in steel or shear cracks in concrete may be present.

CRITICAL CONDITION - advanced deterioration of primary structural elements. Fatigue cracks in steel or shear cracks in concrete may be present or scour may have removed substructure support. Unless closely monitored it may be necessary to close the structure until corrective action can be taken.

“IMMINENT” FAILURE CONDITION - major deterioration or section loss present in critical structural components or obvious vertical or horizontal movement affecting structure stability. Structure is closed to traffic but corrective action may return structure to light service.

FAILED CONDITION - out of service; beyond corrective action.

CONDITION RATING CODE EQUIVALENTS FOR SUB-ELEMENTS

G = GOOD (CODES 7 - 9) F = FAIR (CODES 5 - 6) P = POOR (CODES 0 - 4)

61. CHANNEL 4

P ALIGNMENT1.

G EROSION AND/OR SCOUR2.

N 3. CHANNEL PROTECTION

P4. WATERWAY OBSTRUCTIONS

N 5. OTHER

6. ADEQUACY OF OPENING SUFF

NORMAL VELOCITY MED 7.

6 FT.AVG. CLEAR OPENING 8.

ITEM REFERENCE AND REMARKS

9. STREAM BED COMPOSITION :

STONES, GRAVEL, SILT

62. CUL VERT 6

PARAPETS AND/OR RAILINGS 9.

ADEQUACY OF COVER 8.

SETTLEMENT AND/OR DEFLECTION 7.

EROSION AND/OR SCOUR 6.

5. DEBRIS AND/OR SILT

4. WINGWALLS

3. HEADWALLS

2. FOOTINGS

1. BARREL(S)

ROADWAY SURFACE10.

11. RIDEABILITY

12. OTHER

F

G

F

F

F

F

G

G

N

F

G

N

222. APPROACHES 6

OTHER9.

8. ALIGNMENT

SIGNS 7.

6. SETTLEMENT

EROSION5.

SURFACING4.

APPROACH GUARDRAIL3.

RELIEF JOINTS 2.

APPROACH SLABS1. N

N

N

F

G

G

N

G

N

223. RETAINING WALL N

6. OTHER

5. SETTLEMENT OR DEFLECTION

4. EROSION AND/OR SCOUR

3. FOUNDATION

2. WEEP HOLES

1. WALL

36. TRAFFIC AND SAFETY FEATURES

C. APPROACH GUARDRAILS

B. TRANSITIONS

A. BRIDGE RAILINGS

D. APPROACH GUARDRAIL ENDS

TRAFFIC SAFETY RATING CODES

0 - Does not meet standards or a safety feature is required and none is provided.

1 - Meets currently acceptable standards.

N - Not applicable or a safety feature is not required. 3 OF 16

61.1 UPSTREAM CHANNEL ALIGNMENT VERY SKEWED AND ALMOST

PARALLELS ROADWAY; STREAM FLOW DIRECTED TOWARD SOUTH

WALL OF SOUTH BARREL.

61.4 FALLEN TREES IN UPSTREAM CHANNEL AND AGAINST CENTER

PIER. FALLEN TREE ACROSS DOWNSTREAM CHANNEL.

62.1 WIDESPREAD MINOR RANDOM CRACKING WITH EFFLORESCENCE

ON TOP SLAB; EFFLORESCENCE PRIMARILY NEAR HEADWALLS.

MINOR HONEYCOMBING OF TOP SLAB OF NORTH BARREL AT WEST

END. MINOR CRACKING AND DETERIORATION OF BARREL WALL

MASONRY MORTAR JOINTS; MODERATE AT EAST END AND ALONG

BOTTOM OF SOUTH WALL OF SOUTH BARREL.

62.3,4 MINOR TO MODERATE DETERIORATION OF HEADWALL AND

WINGWALL MASONRY MORTAR JOINTS; MINOR TO MODERATE

EFFLORESCENCE, MOSS, AND VEGETATION GROWTH.

62.5 APPROXIMATELY 3' OF SILT, STONE, AND DRIFT ACCUMULATION IN

NORTH BARREL COVERING WEEP HOLES AND BLOCKING FLOW;

APPROXIMATELY 2' ACCUMULATION AGAINST NORTH WALL OF

SOUTH BARREL.

62.6 MINOR SCOUR ALONG SOUTH WALL OF SOUTH BARREL; STONE

FOOTING EXPOSED UP TO 4" H ALONG LENGTH.

62.10, 222.4,6

MINOR RANDOM CRACKING OF ASPHALT PAVEMENT WITH MINOR

SETTLEMENT.

222.7 NO HEADWALL MARKERS PRESENT.

FIELD INSPECTION REPORT STRUCTURE NO. 5140 007P

ADDITIONAL ITEM REFERENCE AND REMARKS

36.A,B,C,D NO GUARDRAIL SYSTEM PRESENT.

STRUCTURE NO. 5140 007P

INSPECTION DATE: 11/2/16

TRUCK TYPE

TONS

INVENTORY RATING (NORMAL TRAFFIC)

METRIC TONS METRIC TONSTONS

OPERATING RATING (MAXIMUM LOAD)

H

HS

TYPE 3

TYPE 3S2

TYPE 3-3

DESIGN LOADING:

DATE OF LOAD RATING CALCULATION:

LOAD RATING CONTROLLED BY:

REMARKS:

CAPACITY MEETS OR EXCEEDS DESIGN LOAD

CAPACITY IS LESS THAN DESIGN LOAD

ORIGINAL LOAD RATING CALCULATION APPLICABLE

ORIGINAL LOAD RATING CALCULATION REVISED

TOP SLAB

8/15

X

X

STRUCTURE LOAD RATING

OTTER CREEK CULVERT #1

H15 (M13.5)

STRUCTURE INVENTORY AND APPRAISAL STRUCTURE NO. 5140 007P

STRUCTURE IDENTIFICATION

(201) PARK: BLUE RIDGE PARKWAY (1) STATE: ....................................... 513 - VIRGINIA (VA)

(202) STRUCTURE NAME: .......... OTTER CREEK CULVERT #1 (2) STATE HWY. AGENCY DIST:

(203) STRUCTURE KIND: ............2 - CULVERT (3) COUNTY CODE: ........................ 009 - AMHERST

(4) CITY/PLACE CODE:

(204) STRUCTURE NUMBER: ..... 5140-007P

(205) NPS REGION: .................... 4 - SOUTHEAST (5) INVENTORY ROUTE:

(206) ROUTE CODE NUMBER: ... 1 (6) FEATURES INTERSECTED:....... OTTER CREEK

(207) ROAD SECTION NO: ..........007P (7) FACILITY CARRIED: .................. BLUE RIDGE PARKWAY

(208) NPS ROAD CLASS: ............ 1 - PRINCIPAL PARK ROAD (8) STATE STRUCTURE NO: .......... 5140007P0000000

(209) WITHIN NPS BNDRY?: ....... YES (9) LOCATION: ................................ 4.9 MILES TO VA ROUTE 130

(210) OPERATING UNIT: ............. JAMES R. (10) INV. RTE. - MIN. VERT. CLR: .. 99.99 FT (99.99 M)

(211) PROJECT NO(S): ................ 1G2 (11) MILE POINT: ............................. 56.58 (KM PT 91.05)

(212) DRAWING NUMBERS: ....... 3000 (27) YEAR BUILT:

(21) MAINTAINED BY: ................. 66 - NATIONAL PARK SERVICE (106) YEAR RECONSTRUCTED: .... N/A

(22) OWNER: ............................... 66 - NATIONAL PARK SERVICE (20) TOLL: ........................................ 3 - FREE ROAD

(37) HISTORICAL DESIGNATION: .. 5 - NOT ELIGIBLE

STRUCTURE DESCRIPTION, FOUNDATION, AND DECK TYPE

(43A) MAIN STR. MATERIAL: ..

(43B) MAIN STR. TYPE:

(45) NO. OF MAIN SPANS:

(48) MAX. SPAN LENGTH:

(49) STRUCTURE LENGTH:

(216A) ABUTMENT #1 FDN:

(216B) ABUTMENT #2 FDN:

(217A) PREDOM. PIER FDN.: ..

(217B) SECOND. PIER FDN: ...

(107) DECK TYPE:

2 - CONCRETE CONTINUOUS

19 - CULVERT

20.5 FT (6.2 M)

43.7 FT (13.3 M)

2 - SPREAD FTG ON BEARING MAT'L

2 - SPREAD FTG ON BEARING MAT'L

2 - SPREAD FTG ON BEARING MAT'L

2 - SPREAD FTG ON BEARING MAT'L

N - NOT APPLICABLE

(44A) APPR. STR. MATERIAL: ........ 0 - OTHER

(44B) APPR. STR. TYPE: ................ 00 - OTHER

(46) NO. OF APPROACH SPANS: .. 0

(108) WEAR SURFACE/PROTECT SYSTEM:

A) TYPE WEARING SURFACE: .. N - NOT APPLICABLE

B) TYPE MEMBRANE: ................. N - NOT APPLICABLE

C) TYPE PROTECTION:

N - NOT APPLICABLE

NO(218) IS SALT USED?:

LOAD RATING AND POSTING

(31) DESIGN LOAD:

2 - H15 (M13.5) (41) LOAD RESTRICTION:

R - POSTED (OTHER)

(66) INVENTORY RATING: ...... 28.0 TONS (25.4 METRIC TONS) (70) BRIDGE POSTING: .............. 5 - NO POSTING REQUIRED

(64) OPERATING RATING: ...... 47.0 TONS (42.6 METRIC TONS)

INSPECTION DATES

(90) INSPECTION DATE: 11/16 (91) FREQ. OF INSP: 24 MONTHS (92 / 93) CRITICAL FEATURE INSPECTION (CFI):

(219) ADD. STUDIES NEEDED: N - 0 - NONE (A) FRACTURE CRITICAL: ... NO

INSP. EVERY: MONTHS - LAST INSP. : (220) SPECIAL STUDY TYPE: 0 - NONE

(B) UNDERWATER: .............. NO

(221) SPECIAL STUDY DATE:

INSP. EVERY: MONTHS - LAST INSP. :

(C) SPECIAL INSPECTION: .. NO

INSP. EVERY: MONTHS - LAST INSP. :

STRUCTURE INVENTORY AND APPRAISAL STRUCTURE NO. 5140 007P

GEOMETRY, TRAFFIC, AND NAVIGATIONAL DATA

(16) LATITUDE: ............................. 37°37'28.80" (51) CURB TO CURB WIDTH: ........... 0.0 FT (0.0 M)

(17) LONGITUDE: ......................... 79°20'05.10" (52) DECK WIDTH: ............................ 0.0 FT (0.0 M)

(19) DETOUR LENGTH: ............... 25 MI (40 KM) (32) APPR. ROADWAY WIDTH: ........ 38.0 FT (11.6 M)

(28A) LANES ON STRUCT: .......... 02 (213) APPR. PAVEMENT WIDTH: ..... 22.0 FT (6.7 M)

(28B) LANES UNDER STRUCT: ... 00 LEFT SHOULDER: .................. 8.0 FT (2.4 M)

(42A) SERVICE ON: ..................... 1 - HIGHWAY RIGHT SHOULDER: ................ 8.0 FT (2.4 M)

(42B) SERVICE UNDER: .............. 5 - WATERWAY (33) BRIDGE MEDIAN: ....................... 0 - NO MEDIAN

(29) AVG. DAILY TRAFFIC: .......... 474 (34) SKEW ANGLE: ............................ 30 °

(30) YEAR OF ADT: ...................... 2012 (35) DECK FLARE?: ........................... NO

(114) FUTURE ADT: ..................... 521 (47) TOTAL HORIZ. CLEARANCE: .... 38.0 FT (11.6 M)

(115) YEAR OF FUTURE ADT: ..... 2032 (50) SIDEWALKS:

(101) PARALLEL STRUCTURE: ... N - NONE LEFT : ...................................... 0.0 FT (0.0 M)

(38) NAVIGATION CONTROL?: ... 0 RIGHT : ................................... 0.0 FT (0.0 M)

(39) VERTICAL CLEARANCE: ...... 0.0 FT (0.0 M) (214) BRIDGE RAIL TYPE:

(40) HORIZ. CLEARANCE: ........... 0.0 FT (0.0 M) RAIL CONFIGURATION: ......... 0 - N/A

(111) ABUT. OR PIER PROT: ....... MATERIAL: .............................. 0 - N/A

DESIGN TYPE: ........................ 0 - N/A

LATERAL UNDERCLEARANCE:

(55) RIGHT: ....................... 0.0 FT (0.0 M) (215) BRIDGE RAIL HEIGHT: ............ 0.00 FT (0.00 M)

(56) LEFT: ......................... 0.0 FT (0.0 M) (53) MIN. VRT. CLEAR. OVER DECK: 99.99 FT (99.99 M)

(54) MIN. VRT. UNDERCLEARANCE: 0.00 FT (0.00 M)

CONDITION AND APPRAISAL DATA, PROPOSED IMPROVEMENTS, AND COST

(58) DECK: .................................N

(59) SUPERSTRUCTURE: .........N

(60) SUBSTRUCTURE: ..............N

(61) CHANNEL:

(62) CULVERT:

(222) APPROACHES:

(223) RETAINING WALL: ........... N

(36) TRAFFIC SAFETY FEAT: ... 0000

(75A) TYPE OF WORK:

(75B) WORK DONE BY:

(76) IMPROVEMENT LENGTH: ..

(67) STRUCTURAL EVALUATION:

(68) DECK GEOMETRY:

(69) UNDERCLEARANCES:

(71) WATERWAY ADEQUACY:

(72) APPROACH ALIGNMENT:

(113) SCOUR CRITICAL:

(225) PURPOSE OF IMPROVEMENT:

(226) PRIORITY OF IMPROVEMENT:

(227) MAINTENANCE COST:

(228) REHAB./RECONSTR. COST: ...

(229) CONSTRUCTION COST:

N

8 - Stable; scour above top of fo

2 - REHAB/RECONSTRUCTION

D - MINOR

ADDITIONAL INFORMATION

(230) STRUCTURE HISTORY:

1984-JOINT REPAIR.

(231) ADDITIONAL CONSIDERATIONS:

(330) ADDITIONAL CONFIG. INFO.:

CULVERT LENGTH = 50'.

http:79�20'05.10 http:37�37'28.80

APPENDIX STRUCTURE NO. 5140 007P

PHOTOGRAPHS STRUCTURE NO. 5140 007P

FLOW

PHOTO #1 - LOOKING SOUTHBOUND TOWARD ROANOKE

PHOTO #2 - WEST (UPSTREAM) SIDE

PHOTO #3 - GENERAL TOP SIDE VIEW LOOKING NORTH

PHOTO #4 - TYPICAL RANDOM CRACKING OF NORTH APPROACH

PAVEMENT AT NORTHBOUND LANE

STRUCTURE NO. 5140 007PPHOTOGRAPHS

PHOTO #5 - GENERAL UNDERSIDE VIEW OF BARREL #2 LOOKING

WEST

PHOTO #6 - GENERAL VIEW OF NORTH WALL AT NORTH BARREL; NOTE

SEDIMENT ACCUMULATION ALONG NORTH WALL FACE

STRUCTURE NO. 5140 007P

PHOTO #7 - TYPICAL RANDOM CRACKING OF

TOP SLAB WITH EFFLORESCENCE; EAST END

OF SOUTH BARREL SHOWN

PHOTO #8 - CRACKING AND DETERIORATION

OF MASONRY MORTAR JOINTS AT EAST END

OF SOUTH WALL OF SOUTH BARREL

PHOTOGRAPHS

PHOTO #9 - TYPICAL DETERIORATION IN MASONRY MORTAR JOINTS IN

SOUTH ABUTMENT WALL AT EAST END

PHOTO #10 - TYPICAL DETERIORATION OF HEADWALL MASONRY

MORTAR JOINTS; EAST SIDE OF BARREL #2 SHOWN; NOTE ALSO MOSS

AND VEGETATION GROWTH

PHOTO #11 - TYPICAL DETERIORATION OF WINGWALL MASONRY

MORTAR JOINTS; SOUTHEAST WINGWALL SHOWN

PHOTO #12 - ACCUMULATION OF SEDIMENT, STONES, AND DRIFT

ALONG BARREL #2

PHOTO #13 - SCOUR AND UNDERMINING AT WEST END OF SOUTH

ABUTMENT BASE

PHOTO #14 - TYPICAL FOUNDATION EXPOSURE OF SOUTH WALL OF

SOUTH BARREL; DOWNSTREAM END SHOWN (PHOTO FROM

10/29/2014 INSPECTION REPORT)

PHOTO #15 - UPSTREAM CHANNEL; NOTE FALLEN TREES

PHOTO #16 - DOWNSTREAM CHANNEL