Sherwin Williams Seaguard Ablative Antifouling Coating.pdf
PDF 411 KB Posted
- Solicitation number
- 6933A225Q000008
About this file
This document is a Product Information and Application Bulletin for Sherwin-Williams Seaguard Ablative Antifouling Coating, a marine protective coating designed for underwater vessel surfaces. The coating is an advanced antifouling product based on a polyamide polymer containing cuprous oxide, available in red (P30RQ10), black (P30BQ12), and blue (P30LQ13) colors. It is recommended for underwater surfaces of steel vessels operating in coastal and oceanic waters, with key features including long life, multiple application methods (brush, roll, spray), and compliance with MIL-PRF-24647 specifications.
The technical data sheet provides comprehensive details on product characteristics, including a flat finish, 65% volume solids, VOC content under 400 g/L, and recommended spreading rates of 4.0-7.0 wet mils per coat. Application instructions specify surface preparation requirements such as near-white metal blast cleaning for bare steel, careful mixing, and specific application conditions including maximum temperature of 120°F and surface temperature at least 5°F above the dew point. The coating is designed to maintain a bio-active surface throughout its lifetime, with the surface gradually sacrificing itself to prevent marine fouling, and the color changing over time in direct contact with seawater.
View the file
Other files
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SEAGUARD® ABLATIVE
ANTIFOULING COATING
P30RQ10 ................. R
P30BQ12 ............. B P30LQ13 ......................B
Protective
Marine Coatings
9.12Revised: January 2, 2024 www.sherwin-williams.com/protective
P D SEAGUARD ABLATIVE ANTIFOULING COATING is an advanced antifouling coating based on a polyamide polymer containing cu-prous oxide. Recommended for the underwater surfaces of steel vessels operating in all coastal and oceanic waters. This product maintains an eff ective, bio-active surface during its entire life.
• Long Life
• Brush, roll, or spray application
• A tin-free ablative coating
• Complies with the requirements of MIL-PRF-24647
P C Finish: Flat
Color: Red, Black, and Blue
Volume Solids: 65% ± 2%
VOC (EPA Method 24): <400 g/L; 3.33 lb/gal, maximum
Recommended Spreading Rate per coat:
Minimum Maximum
Wet mils (microns) 4.0 (100) 7.0 (175) Dry mils (microns) 2.5 (63) 4.0 (100) ~Coverage sq ft/gal (m2/L) 260 (6.4) 430 (10.5) Theoretical coverage sq ft/gal (m2/L) @ 1 mil / 25 microns dft 1040 (25.5)
NOTE: Brush or roll application may require multiple coats to achieve maximum fi lm thickness and uniformity of appearance.
Drying Schedule @ 5.0 mils wet (125 microns):
30°F/-1.1°C 50°F/10°C 70°F/21°C 85°F/29°C 100°F/38°C
50% RH
To recoat:
minimum: 32 hrs 16 hrs 8 hrs 4 hrs 2 hrs Undocking*: 48 hrs 24 hrs 12 hrs 8 hrs 4 hrs No maximum recoat time; however, any contamination must be removed by high pressure washing prior to applying the next coat.
*Undocking:
Minimum: depends on the number of coats applied, fi lm thickness, and temperature.
Maximum: depends on the exposure conditions. Refer to Performance Tips section for details.
Shelf Life: 36 months, unopened Store indoors at 40°F (4.5°C) to 100°F (38°C)
Flash Point: 72°F (22°C), SETA Flash Reducer/Clean Up: VM&P Naphtha, R1K3 continued on back
R U For use on prepared surfaces in underwater surfaces of steel vessels.
• As an antifoulant for underwater hull and boot top on vessels operating in global trade with short to medium idle times.
• Suitable for a wide range of operating environments and speeds
P C
• Resists fouling
• Contains 49% Cuprous Oxide
• Colors:
Red P30RQ10 Black P30BQ12 Blue P30LQ13
P30RQ10 ................. R
P30BQ12 ............. B P30LQ13 ......................B
Protective
Marine Coatings
9.12Revised: January 2, 2024 www.sherwin-williams.com/protective
S P
Surface must be clean, dry, and in sound condition. Remove all oil, dust, grease, dirt, loose rust, and other foreign material to ensure adequate adhesion.
Refer to product Application Bulletin for detailed surface prepara-tion information.
Minimum recommended surface preparation:
Iron & Steel, bare: SSPC-SP10/NACE 2 (For anticorrosive primer coat) Previously Painted: Clean, dry, sound
Surface Preparation Standards Condition of Surface
ISO 8501-1
BS7079:A1
Swedish Std.
SIS055900 SSPC NACE
White Metal Sa 3 Sa 3 SP 5 1 Near White Metal Sa 2.5 Sa 2.5 SP 10 2 Commercial Blast Sa 2 Sa 2 SP 6 3 Brush-Off Blast Sa 1 Sa 1 SP 7 4 Hand Tool Cleaning Rusted C St 2 C St 2 SP 2 -
Pitted & Rusted D St 2 D St 2 SP 2 - Power Tool Cleaning Rusted C St 3 C St 3 SP 3 -
Pitted & Rusted D St 3 D St 3 SP 3 -
T Do not tint.
A C
• Maximum application temperature is 120°F (49°C)
• Surface temperature must be at least 5°F (2.8°C) above the dew point
• No surface ice, moisture, or condensation may be allowed on the surface during application
O I Packaging: 5 gallon (18.9L) containers
Weight: 18.5 ± lb/gal ; 2.22 Kg/L
S P Refer to the SDS sheet before use.
Published technical data and instructions are subject to change without notice.
Contact your Sherwin-Williams representative for additional technical data and instructions.
W The Sherwin-Williams Company warrants our products to be free of manufactur-ing defects in accord with applicable Sherwin-Williams quality control procedures.
Liability for products proven defective, if any, is limited to replacement of the defec-tive product or the refund of the purchase price paid for the defective product as determined by Sherwin-Williams. NO OTHER WARRANTY OR GUARANTEE
OF ANY KIND IS MADE BY SHERWIN-WILLIAMS, EXPRESSED OR IMPLIED,
STATUTORY, BY OPERATION OF LAW OR OTHERWISE, INCLUDING MER-
CHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
P I R S
Dry Film Thickness / ct.
Mils (Microns) Steel:
2 cts. SeaGuard 5000 HS 5.0 -7.0 (125-175) 1-3 cts. SeaGuard Ablative Antifouling 2.5-4.0 (63-100) NOTE: Number of coats is dependent on specifi cation, existing hull conditions, and intended service life.
Previously Painted:
1-3 cts. SeaGuard Ablative Antifouling 2.5-4.0 (63-100) NOTE: Number of coats is dependent on specifi cation, existing hull conditions, and intended service life.
The systems listed above are representative of the product's use, other systems may be appropriate.
D The information and recommendations set forth in this Product Data Sheet are based upon tests conducted by or on behalf of The Sherwin-Williams Company.
Such information and recommendations set forth herein are subject to change and pertain to the product off ered at the time of publication. Consult your Sherwin- Williams representative to obtain the most recent Product Data Information and Application Bulletin.
P30RQ10 ................. R
P30BQ12 ............. B P30LQ13 ......................B
Protective
Marine Coatings
9.12Revised: January 2, 2024 www.sherwin-williams.com/protective
S P
Surface must be clean, dry, and in sound condition. Remove all oil, dust, grease, dirt, loose rust, and other foreign material to ensure adequate adhesion.
Iron & Steel, bare Minimum surface preparation is Near White Metal Blast per SSPC-SP10/NACE 2. Remove all oil and grease from surface by Solvent Cleaning per SSPC-SP1. Blast clean all surfaces using a sharp, angular abrasive for optimum surface profile (2 mils / 50 microns). Remove all weld spatter and round all sharp edges by grinding. For surfaces prepared per waterjet cleaning, all surfaces to be coated shall be cleaned in accordance with SSPC-SP WJ-2 L, Very Thorough Cleaning, Light Flash Rust. Pre-existing profile should be approximately 2 mils (50 microns).
Previously Painted Antifouling Surfaces Remove possible oil, grease, etc. with suitable detergent.
Rinse using high pressure, fresh water cleaning, which will also remove any weak, outer layer of leached antifouling.
Allow the surface to dry before overcoating.
Whether or not to use a sealer coat over an existing antifouling depends on the type and condition of the existing antifouling.
Surface Preparation Standards Condition of Surface
ISO 8501-1
BS7079:A1
Swedish Std.
SIS055900 SSPC NACE
White Metal Sa 3 Sa 3 SP 5 1 Near White Metal Sa 2.5 Sa 2.5 SP 10 2 Commercial Blast Sa 2 Sa 2 SP 6 3 Brush-Off Blast Sa 1 Sa 1 SP 7 4 Hand Tool Cleaning Rusted C St 2 C St 2 SP 2 -
Pitted & Rusted D St 2 D St 2 SP 2 - Power Tool Cleaning Rusted C St 3 C St 3 SP 3 -
Pitted & Rusted D St 3 D St 3 SP 3 -
A B A C
• Maximum application temperature is 120°F (49°C)
• Surface temperature must be at least 5°F (2.8°C) above the dew point
• No surface ice, moisture, or condensation may be allowed on the surface during application
A E
The following is a guide. Changes in pressures and tip sizes may be needed for proper spray characteristics. Always purge spray equipment before use with listed reducer. Any reduction must be compliant with existing VOC regulations and compatible with the existing environmental and application conditions.
Reducer/Clean Up ...........VM&P Naphtha, R1K3
Airless Spray Pressure.........................3600 psi Hose...............................3/8" ID Tip ...................................023" - .027" Filter ...............................100 mesh Reduction .......................as needed up to 5% by volume
Brush Brush..............................Natural Bristle Reduction .......................as needed up to 5% by volume
Roller Cover .............................3/8" woven with solvent resistant core Reduction .......................as needed up to 5% by volume
If specifi c application equipment is not listed above, equivalent equipment may be substituted.
continued on back
P30RQ10 ................. R
P30BQ12 ............. B P30LQ13 ......................B
Protective
Marine Coatings
9.12Revised: January 2, 2024 www.sherwin-williams.com/protective
A B A P
Surface preparation must be completed as indicated.
Mixing Instructions: Mix paint thoroughly with low speed power agitation prior to use. Make sure there is no settling on the bottom of the can.
Apply paint at the recommended fi lm thickness and spreading rate as indicated below:
Recommended Spreading Rate per coat:
Minimum Maximum
Wet mils (microns) 4.0 (100) 7.0 (175) Dry mils (microns) 2.5 (63) 4.0 (100) ~Coverage sq ft/gal (m2/L) 260 (6.4) 430 (10.5) Theoretical coverage sq ft/gal (m2/L) @ 1 mil / 25 microns dft 1040 (25.5)
NOTE: Brush or roll application may require multiple coats to achieve maximum fi lm thickness and uniformity of appearance.
Drying Schedule @ 5.0 mils wet (125 microns):
30°F/-1.1°C 50°F/10°C 70°F/21°C 85°F/29°C 100°F/38°C
50% RH
To recoat:
minimum: 32 hrs 16 hrs 8 hrs 4 hrs 2 hrs Undocking*: 48 hrs 24 hrs 12 hrs 8 hrs 4 hrs No maximum recoat time; however, any contamination must be removed by high pressure washing prior to applying the next coat.
*Undocking:
Minimum: depends on the number of coats applied, fi lm thickness, and temperature.
Maximum: depends on the exposure conditions. Refer to Performance Tips section for details.
Application of coating above maximum or below minimum recommended spreading rate may adversely aff ect coating performance.
C U I Clean spills and spatters immediately with VM&P Naphtha, R1K3. Clean tools immediately after use with VM&P Naphtha, R1K3. Follow manufac-turer's safety recommendations when using any solvent.
D The information and recommendations set forth in this Product Data Sheet are based upon tests conducted by or on behalf of The Sherwin-Williams Company.
Such information and recommendations set forth herein are subject to change and pertain to the product off ered at the time of publication. Consult your Sherwin- Williams representative to obtain the most recent Product Data Information and Application Bulletin.
P T When using spray application, use a 50% overlap with each pass of the gun to avoid holidays, bare areas, and pinholes. If necessary, cross spray at a right angle
Spreading rates are calculated on volume solids and do not include an application loss factor due to surface profi le, roughness or porosity of the surface, skill and technique of the applicator, method of application, various surface irregularities, material lost during mixing, spillage, overthinning, climatic conditions, and excessive fi lm build.
Excess reduction of material is not recommended as it can aff ect fi lm build, appearance, and adhesion.
In order to avoid blockage of spray equipment, clean equipment before use or before periods of extended downtime with VM&P Naphtha, R1K3.
When applying over the recommended epoxy coat, the epoxy shall be tacky, but not hard. "Tacky" is defi ned as that curing (drying) stage when a fi ngertip pressed lightly against the fi lm leaves only a slight impression and none of the fi lm sticks to the fi nger.
By providing a constantly active surface during its lifetime, this antifouling is gradually sacrifi ced in the process. The color of the system changes in accordance with the colors of the coats applied, e. g.: Light red changes to whitish in direct contact with seawater.
Indicated fi lm thickness will vary according to specifi cation. This will alter spreading rate and may infl uence drying time. In case of multi-coat applica-tion, drying time and minimum overcoating interval will be infl uenced by the number of coats and by the thickness of each coat applied.
Overcoating: No maximum overcoating interval, but after prolonged expo-sure to polluted atmosphere, remove accumulated contamination by high pressure fresh water cleaning and allow to dry before applying next coat.
Undocking: Minimum undocking time depends on number of coats applied, fi lm thickness, and the prevailing temperature.
Maximum undocking time depends on the exposure conditions, degree of air pollution, etc. The most important factor is to carry out a thorough high pressure fresh water cleaning after prolonged exposure. Outfi tting of up to 6 months followed by such cleaning normally presents no problem. Longer outfi tting periods to be evaluated from case to case. The recommended maximum undocking interval relates to vertical bottom only. Flat bottom, which has not been exposed to direct sunlight, will for all normal practical building schedules have a no-maximum value.
Refer to Product Information sheet for additional performance charac-teristics and properties.
S P Refer to the SDS sheet before use.
Published technical data and instructions are subject to change without notice.
Contact your Sherwin-Williams representative for additional technical data and instructions.
W The Sherwin-Williams Company warrants our products to be free of manufacturing defects in accord with applicable Sherwin-Williams quality control procedures.
Liability for products proven defective, if any, is limited to replacement of the de-fective product or the refund of the purchase price paid for the defective product as determined by Sherwin-Williams. NO OTHER WARRANTY OR GUARANTEE
OF ANY KIND IS MADE BY SHERWIN-WILLIAMS, EXPRESSED OR IMPLIED,
STATUTORY, BY OPERATION OF LAW OR OTHERWISE, INCLUDING MER-
CHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
File details come from the government source that posted it. Updated .