Sea_valves_REQUIRING_waster_spool_pieces.docx
DOCX document 33 KB Posted
- Attached to
- T. S. KENNEDY - FY18 Drydock Surveys and Repairs
- Solicitation number
- 6933A218Q000003
About this file
Sea Valves Requiring Water Spool Pieces
View the file
Other files
Show 40 more
Latest 50 of 94 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Manually Operated Skin Valves
| Location |
| Type |
| Waster Piece required |
| Size / Pressure |
| Bolts Per Flange / Bonnet |
| Steaming-Out For Fire Pump Sea Chest Main Sea Scoop |
| 123-Stbd |
| Globe |
| YES |
| 3 / 150 |
| 4 / 4 |
| Flushing Line To Main Sea Scoop |
| 123-Stbd |
| Globe |
| YES |
| 4 / 150 |
| 8 / 8 |
| Bilge/Ballast Pump/Gen'l Serv Pump Sea Suct. |
| 129-Port |
| Gate |
| YES |
| 8 / 150 |
| 8 / 12 |
| Bilge Oily Ballast & F.O. Transfer Pump Sea Suction |
| 129-Stbd |
| Gate |
| YES |
| 6 / 150 |
| 8 / 8 |
| Salt Water Service System Ovbd. Disch. |
| 129-Port |
| Gate |
| YES |
| 6 / 150 |
| 8 / 6 |
| Main & Aux. Circ. Pumps & Bilge Ballast & F.O. Trans. Pump High Sea Chest Vent |
| 129-Stbd |
| Gate |
| YES |
| 5 / 150 |
| 8 / 6 |
| Bilge & Ballast & Gen. Service Pumps Aux. Mach. Serv. Pump Dist. Plant & Fire Main Pump Sea Chest Vent |
| 129-Port |
| Globe |
| YES |
| 5 / 150 |
| 4 / 4 |
| Steaming-Out For Fire Pump Sea Chest Aux. High Sea Chest |
| 129-Port |
| Globe |
| YES |
| 1 / 150 |
| 4 / 4 |
| Fire-Pump Suction Aux. High Sea Chest |
| 129-Port |
| Gate |
| YES |
| 8 / 150 |
| 8 / 10 |
| Boiler-Blowdown Overboard Discharge |
| 129-Stbd |
| Globe |
| YES |
| 2 / 600 |
| 8 / 6 |
| Dist. Feed Pump Sea Suction Aux. High Sea Chest |
| 129-Port |
| Gate |
| YES |
| 6 / 150 |
| 8 / 6 |
| Aux. Mach. Sea Water Service Pump (Standby) High Sea Chest Suction |
| 129-Port |
| Gate |
| YES |
| 6 / 150 |
| 8 / 8 |
| Steaming-Out For Fire Pump Sea Chest Main & Aux. Circ. High Sea Chest |
| 131-Stbd |
| Globe |
| YES |
| 1 / 150 |
| 4 / 4 |
| Steaming-Out For Fire Pump Sea Chest Circ. Low Sea Chest |
| 131-Stbd |
| Globe |
| YES |
| 1 / 150 |
| 4 / 4 |
| Main Circ. Pump Low Sea Chest Vent |
| 131-Stbd |
| Gate |
| YES |
| 5 / 150 |
| 8 / 4 |
| Main Cond. Overboard Discharge Self Venting |
| 132-Port |
| Gate |
| YES |
| 10 / 150 |
| 12 / 12 |
| L.O. Cooler Overboard Discharge |
| 134-Port |
| Gate |
| YES |
| 6 / 150 |
| 8 / 8 |
| Bilge Oily Ballast & F.O. Transfer Pump Ovbd. Disch. |
| 135-Stbd |
| Globe |
| YES |
| 5 / 150 |
| 8 / 10 |
| Contaminated Steam Gen. Blowdown Ovbd. Disch. |
| 135-Port |
| Globe |
| YES |
| 2 / 150 |
| 4 / 4 |
| Aux. Circ Pumps Low Sea Chest Vent |
| 136-Stbd |
| Gate |
| YES |
| 3 / 5 |
| 4 / 6 |
| Dist. Brine Pump Overboard Discharge |
| 136-Port |
| Globe |
| YES |
| 4 / 150 |
| 4 / 6 |
| Steaming-Out For Fire Pump Sea Chest Aux. Low Sea Chest |
| 137-Stbd |
| Globe |
| YES |
| 1 / 150 |
| 4 / 4 |
| Bilge/Ballast Pump Gen. Service Ovbd. Disch. |
| 137-Port |
| Globe |
| YES |
| 5 / 150 |
| 8 / 10 |
| Fire Pump Sea Chest Vent |
| 188-Stbd |
| Globe |
| YES |
| 2 / 150 |
| 4 / 4 |
| Steaming-Out For Fire Pump Sea Chest |
| 188-Stbd |
| Globe |
| YES |
| 1 / 600 |
| 4 / 4 |
| Motor Operated Sea Valves |
| Location |
| Type |
| Size / Pressure |
| Bolts Per Flange / Bonnet |
| SSTG # 2 Aux. Circ. Pump High Sea Suction |
| 130-Stbd |
| Gate |
| YES |
| 10 / 150 |
| 12 / 12 |
| Main Condenser Circ. Pump High-Sea Suction (Motor operator removed) |
| 131-Stbd |
| Gate |
| YES |
| 20 / 150 |
| 20 / 16 |
| SSTG # 1 Aux. Circ Pump High Sea Suction |
| 132-Stbd |
| Gate |
| YES |
| 10 / 150 |
| 12 / 12 |
| SSTG # 2 Condenser Overboard Discharge |
| 135-Stbd |
| Gate |
| YES |
| 8 / 150 |
| 8 / 12 |
| SSTG # 2 Aux. Circ. Pump Low Sea Suction |
| 136-Stbd |
| Gate |
| YES |
| 10 / 150 |
| 12 / 12 |
| SSTG # 1 Condenser Overboard Discharge |
| 136-Stbd |
| Gate |
| YES |
| 8 / 150 |
| 8 / 12 |
| SSTG # 1 Aux. Circ. Pump Low Sea Suction |
| 137-Stbd |
| Gate |
| YES |
| 10 / 150 |
| 12 / 12 |
| Fire-Pump #1 Sea Suction (Shaft Alley) |
| 188-Stbd |
| Gate |
| YES |
| 5 / 150 |
| 8 / 6 |
| Emergency Fire Pump Discharge Check (non-return valve) |
| 121-STBD |
| Globe |
| YES |
| 4/150 |
| 8/8 |
File details come from the government source that posted it.