Seaway Visitor Center_Elevator Inspection Report.pdf
PDF 184 KB Posted
- Attached to
- Elevator Maintenance, Repairs, and Inspection Services Federal contract opportunity
- Solicitation number
- 6923G525Q0599
About this file
This document is an Electric Elevator Acceptance Inspection & Witness of Test Report for a passenger elevator located at the Dwight D. Eisenhower Visitors' Center in Massena, NY. The inspection was conducted by ATIS Elevator Inspections LLC on 5/1/2024 and revealed one non-compliance item: the elevator's communication system does not meet the text capability requirements of NYSBC Rule 3001.2 for emergency two-way communication.
The inspection report includes detailed test results for normal and standby power car operations, showing consistent speeds of 150 fpm (feet per minute) in all directional and load scenarios. Technical specifications include a load of 2500 lbs, a 3-inch F/L stopping distance, and a top of car clearance of 64 inches. The elevator was manufactured by Kone in 2024, follows the ASME A17.1-2016 installation code, and was inspected by NYS licensed personnel. A notable detail is that the Federal Building specifically requested that video and text capabilities not be hooked up.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 6923G525Q0599A00002.pdf | ||
| 6923G525Q0599A00001.pdf | ||
| RFQ 6923G525Q0599.pdf | ||
| Attachment A_PWS.pdf | ||
| Attachment B_Pricing Sheet.xlsx | XLSX spreadsheet | |
| Attachment C_Service Contract Act WD 2015-4169.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Electric Elevator
Acceptance Inspection & Witness of Test Report
MRL Tract Elev Barnhart Island Rd.
Massena, NY 13662 Owner: Dwight D. Eisenhower Visitors' Center
Passenger
Kone
Type Rated Load Year Constructed Manufacturer
5/1/2024
C-6981 NAESA International
Date of Report Inspector QEI Certification # QEI Cert. Issuer
Massena, Village of Workorder Designator Authoritative Jurisdiction
Inspection & Test Items Not In Compliance Per ASME A17.1
Failure Reason Communication System does not comply with text capability requirements of NYSBC RULE 3001.2.
MAY 12th 2020 Emergency Two Way
Inspection Item
Car Emergency signal
Applicable Code Reference
Item 1.6
Test Results
Normal Car Operation Empty Car Speed Up: 150 fpm Empty Car Speed Down: 150 fpm Full Car Speed Up: 150 fpm Full Car Speed Down: 150 fpm
Standby Power Car Operation Empty Car Speed Up: 150 fpm Empty Car Speed Down: 150 fpm Full Car Speed Up: 150 fpm Full Car Speed Down: 150 fpm
Load Load Placed on Car: 2500 lbs
Safeties F/L Stopping Distance (Car): 3 inches Releasing Carrier Force: 0 lbs Pull Through Force: 112 lbs
Governor Data Plate: 210 fpm Trip Speed: 204 fpm
Buffers Runby to CW Buffer: 6 inches
Miscelaneous Top of Car Clearance: 64 inches
Notes
Installation Code ASME A 17.1-2016
NYS Licensed Mechanic # 23-6lPA5-SHEL
NYS Licensed Inspector # 132-22-06338
Federal Building requested that Video and text not be hooked up continued on next page
MRL Tract Elev Barnhart Island Rd.
Massena, NY 13662 Owner: Dwight D. Eisenhower Visitors' Center
5/1/2024
Page Date of Report Inspector Workorder Designator
Inspector's Signature This conveyance inspection was performed in compliance with the applicable provisions of ASME A17.2 Guide for Inspection of Elevators, Escalators, and Moving walks. The owner retains full responsibility to maintain this conveyance in compliance with all applicable laws, ordinances and regulations. The Authority Having Jurisdiction retains all rights and responsibilities, as defined by applicable law, regarding verification of compliance.