Attachment 8 - Revised SOW for Library Circulation Desk.pdf

PDF 167 KB Posted

Attached to
USMMA - LIBRARY CIRCULATION DESK REPLACEMENT
Solicitation number
6923G226Q000044
Issued by

About this file

This is a Statement of Work (SOW) for the procurement and installation of a library circulation desk at the Schuyler Otis Bland Library, U.S. Merchant Marine Academy, Kings Point, New York. The facility is listed on the National Register of Historic Places, requiring all work to comply with the Secretary of the Interior's Standards for the Treatment of Historic Properties and Standards for Rehabilitation (36 CFR parts 68 and 67.7).

The contractor must deliver and install a solid wood circulation desk with a Kensington Maple finish measuring 17.5 to 18 feet in length with a 30-inch depth. The desk requires two computer workstations: a standing-height unit at 39 inches supporting a computer, monitor, keyboard, barcode scanner, and receipt printer, and a second seated workstation at 32 inches (ideally adjustable between 32-36 inches) supporting a computer, monitor, keyboard, and barcode scanner. The desk must have a minimum 300-pound weight capacity, solid wood or quarried stone countertop, built-in cable and wire management, lockable drawers with open adjustable storage, and a full hinged locking door unit with internal adjustable shelves. The contractor is responsible for disassembling and removing the existing desk in compliance with New York State and federal laws, as well as assembling and installing the new desk in the designated circulation area. All work must be completed within 60 calendar days after award during normal business hours (0700-1630, Monday-Friday) unless approved otherwise by the Contracting Officer. Materials and labor are warranted for one year post-installation, with equipment warranted per manufacturer specifications. The contractor must maintain daily work area safety and cleanliness, immediately notify the Contracting Officer (COR) of unforeseen issues, and provide at least three days' advance notice of anticipated service disruptions.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STATEMENT OF WORK

SCHUYLER OTIS BLAND LIBRARY

Library Circulation Desk

U.S. MERCHANT MARINE ACADEMY

KINGS POINT, NEW YORK

August 10, 2026 Prepared by Jan M. Edmiston

U.S. DEPARTMENT OF TRANSPORTATION

MARITIME ADMINISTRATION

U.S. MERCHANT MARINE ACADEMY

BACKGROUND

The United States Merchant Martine Academy (USMMA) is an agency of the Maritime Administration (MARAD) managed by the United States Department of Transportation.

The USMMA is listed on the National Register of Historic Places. Therefore, all work shall be consistent with the Secretary of the Interior's Standards for the Treatment of Historic Properties (36 CFR part 68) http://www.nps.gov/tps/standards/four-treatments/treatment-guidelines.pdf.

All work shall meet or exceed the standards provided in the Secretary of the Interior’s Standards for Rehabilitation and guidelines for applying the standards published by the National Park Service, U.S. Department of the Interior 36 CFR 67.7 - Standards for rehabilitation.

The Schuyler Bland Memorial Library is located on the campus of the USMMA in building

17. The Library circulation desk, all component parts, and supplies will be delivered to the library, and installation will be carried out in the library.

The Library Circulation Desk is the first thing that patrons see when they walk into the library, and so it should have a good appearance and match the existing furnishings. The library recently had a refresh in which the furniture on the main floor was replaced having a Kensington maple style and color wood finish. A new circulation front desk of a very strong and durable quality and having a Kensington maple color finish to match the existing décor is needed.

A critical need for the library is that the circulation desk needs to be constructed of solid wood to withstand the heavy use and materials placed on the desk surface. At the end of each trimester, thousands of library books are returned within a two-three day period. Books are stacked high on the circulation desk for sorting and check-in by library staff members. Desk-tops and surfaces need to be strong enough to support the possibility of people sitting on the top of the work stations, or leaning up against the desk. A minimum weight capacity of 300 pounds is essential.

Additionally, the top of the circulation desk must be strong enough to hold up to daily pushing books and other materials across the top of the desk. Laminate materials will not hold up to this heavy use. A stained, solid wood or quarried stone material is needed to withstand this level of daily use. Plastic or laminate surfaces are not sufficient for this level of use.

The desk needs to accommodate all of the standard functional needs of the library which the current, worn-out and falling apart desk provides. Specifically, a standing height work station to support a computer, barcode scanner, and receipt printer with a desk height of 39” is needed. A second computer workstation capable of supporting a computer and barcode scanner with a desktop measuring a standard 32” from the floor is needed.

SCOPE

The vendor will deliver all component parts of the library circulation desk to the Schuyler Bland Memorial Library, USMMA. The vendor will disassemble the existing desk and will dispose of it in a location off the USMMA campus, in accordance with all New York State and federal laws. The vendor will assemble and install the desk in the area designated by the library COR

DELIVERABLES

The Contractor is responsible for the following;

1. It must have a minimum weight capacity of 300 lbs.

2. It must include a standing height workstation to support a computer, monitor, keyboard, barcode scanner, and receipt printer with a desk height of 39.”

3. It must also include a second, separate seated computer workstation capable of supporting a computer, monitor, keyboard, and barcode scanner with a desktop measuring a standard 32” from the floor. Ideally, the desktop height should be possible to be adjusted between 32 and 36” from the floor.

4. It must be of solid wood construction with a solid wood or quarried stone or equivalent strength countertop

5. It must have a light colored, Kensington Maple finish

6. The straight, front of the circulation desk, with all units assembled must be of a length of 17 ½ to 18 feet

7. The desktop must have a depth of 30” and height of 39” for all but the one, seated workstation which would have a depth of 30” but a desktop height of 32” inches from the floor, ideally, with the ability to adjust the height of this desktop.

8. It must include built-in cable and wire management.

9. It must have lockable drawers with open, adjustable storage below

10. It must include a full, built-in hinged door unit capable of locking with internal adjustable shelves

11. It must include disassembly and removal of the existing desk in the vendor’s vehicle to a site off the USMMA campus, in accordance with New York State and federal laws.

12. It must include assembling and installing the new desk in the circulation area, in the place indicated by the library COR.

GENERAL

1. The contractor shall provide all labor and material, transportation and supervision in the performance of all tasks detailed in this statement of work.

2. All work is to conform to federal, state and local regulations and codes.

3. Maintain a work area compliant with safety standards.

4. Areas worked on shall be cleaned and secured on a daily basis.

5. Any damage to existing facilities or appurtenances shall be repaired or replaced in kind, by the contractor at no cost to the Government.

6. Examine existing conditions prior to beginning work.

7. Excess material and debris shall be disposed of in accordance with local and state ordinances.

8. No vehicles shall be driven on the sidewalks or grass.

9. Make every effort to minimize the impact to the daily routine of the Academy.

CLOSE OUT:

The contractor shall provide a signed warranty of any damage, defective material and improper workmanship on any material provided in this contract.

Materials and labor to be warranted for one year after installation, and equipment to be warranted per manufacturer

SUBMITTALS

Library circulation desk modules, as per contract line items

GOVERNMENT FURNISHED PROPERTY, MATERIAL, EQUIPMENT OR

INFORMATION.

N/A

CONSIDERATIONS

• Maintain communication with the COR (and immediately inform the COR of any unforeseen issues or problems that arise).

• Inform COR of any anticipated disruption in services at least three (3) days in advance

PLACE OF PERFORMANCE

Contractor will perform the task at the Schuyler Otis Bland Library, located at the USMMA, 300 Steamboat Road, Kings Point, N.Y. 11024

PERIOD OF PERFORMANCE

Work is to be completed within 60 calendar days after Award. Work is to be performed during normal business hours 0700 to 1630, Monday through Friday unless approval is granted by the Contracting Officer.

File details come from the government source that posted it. Updated .