A.1
A. GENERAL INFORMATION
B. SUMMARIES
INDEX TO SHEETS
SUMMARY OF QUANTITIES
C. TYPICAL SECTIONS
I.1-4
J. TEMPORARY TRAFFIC CONTROL
K. PERMANENT TRAFFIC CONTROL
K.1 PERMANENT TRAFFIC CONTROL QUANTITIES
K.2
K.3
K.4
SITE 38 PLAN
SITE 36 PLAN
SITE 33 PLAN
K.5
K.6
K.7 LINEAR PAVEMENT MARKINGS
WASHINGTON DELINEATORS
SIGN INSTALLATION, WOOD POSTS
J.1 TEMPORARY TRAFFIC CONTROL QUANTITIES
J.2
J.3
J.4
J.5
ADVANCE ROAD CLOSURE SIGNAGE
ADVANCE SIGNING
(WITH FLAGGERS)
SINGLE LAND CLOSURE LAYOUT
INSTALLATION, WOOD POSTS
TEMPORARY TRAFFIC CONTROL SIGN
DRAPED ROCKFALL PROTECTION DETAILSI.5-7
CABLE NET DRAPED MESH DETAILS
GABION BASKETI.8
I. ROCKFALL PROTECTION
A.1 PLAN SYMBOLS AND ABBREVIATIONS
A.1
TITLE SHEET
VICINITY MAP
PROTECTION SECTIONS
TYPICAL ROADSIDE ROCKFALLC.1
B.1-3
D.1
D.2
D.3
D.4
SITE 38 PLAN
SITE 36 PLAN
D.5
D.6
D. PLAN-PROFILE
SURVEY CONTROL
ROADWAY QUANTITIES
SITE 33 PLAN
EIGHT MILE PIT
E.1
E.2
E.3
E.4
E.5
E.6
E. EROSION CONTROL
EROSION CONTROL QUANTITIES
EROSION CONTROL PLAN SITE 38
EROSION CONTROL PLAN SITE 36
EROSION CONTROL PLAN SITE 33
SILT FENCE
INLET DETAILS
FIBER ROLL CHECK DAM AND CULVERT
F. CONCRETE BARRIERS
CONCRETE BARRIER DETAILSF.1
PRELIMINARY - NOT FOR CONSTRUCTION
PRELIMINARY - N
OT FOR CONSTRUCTION
jj u
6' - 12' See Note 4
. s E:
Lr)
Break-away holes.
See post detail (typ.)
l.t)
Q
QJ
QJ
l.t)
.s � Q E: <:
QJ
QJ
SINGLE POST SIGN
WOOD POST SELECTION TABLE
WIDTH AREA NUMBER POST SIZE D
"X" (SQFT) OF POSTS (INCH) (INCH)
Diamond=,; 36" < 10
1 4x4 36 Other Shapes=,; 48" 1 4x6 48
Diamond=,; 48" 10 - 20 1 6x6 48
Diamond=,; 48" 10 - 20 2 4x4 36 Other Shapes =5 12' 20 - 50 2 4x6 48
> 13' 50 - 65 2 6x6 48 12' - 16' 50 - 65 3 4x6 48
> 17' 65- 95 4 4x6 48 > 30' 65- 95 3 6x6 48
0.75X
HOLE SIZE
(INCH)
1.5
1.5
1.5 1.5
0.2X
TWO POST SIGN
□ Post
X
0.6X 0.2X
:l: :l:
a
Long side of post
=rr
Bottom of sign panel
Field drill holes through post parallel to sign face.
See table for hole size
POST DETAIL
PROJECT
WA USFS OKWEN617 76(1)
NOTE:
1. Attach sign panels with a minimum of 2 - ¼" dia. bolts per post.
2. H1 and H2 = Overall post length.
Select post lengths to fit field conditions.
3. D = Post embedment depth for average soil conditions.
4. In areas where lateral distance is limited, a minimum lateral offset of 2' may be used. In areas with curbs, a minimum lateral distance of 1' behind the face of the curb may be used .
5. In pedestrian locations, or in areas with obstructed views, use 7' minimum mounting height for main sign and 6' minimum mounting height for secondary sign.
6. Use 7' minimum spacing between posts for sign posts 6" x 6" or larger.
7. State standards may be used as an alternative if approved by the CO.
!"'goo
• 200' 937 On tangent alignment
SIGN INSTALLATION ANGLE
U.S. DEPARTMENT OF TRANSPORTATION
FEDERAL HIGHWAY ADMINISTRATION
OFFICE OF FEDERAL LANDS HIGHWAY
SHEET
NUMBER
J.5
FLH STANDARD
TEMPORARY TRAFFIC CONTROL
SIGN INSTALLATION
WOOD POSTS
NO SCALE
STANDARD APPROVED FOR USE 6/2005
REVISED: 7/2022
STANDARD
635-14