Amendment_A001.pdf
PDF 4 MB Posted
- Solicitation number
- 69056718B000017
About this file
Amendment A001
View the file
Other files
| File | Type | Posted |
|---|---|---|
| BidSum.pdf | ||
| A003.pdf | ||
| A002.pdf | ||
| Q&A_06-13-18.pdf | ||
| Plan_Request_Form.pdf | ||
| IFB_Exit_Glacier_Rd.pdf | ||
| KEFJ1005_Plan_Set.pdf | ||
| PROJECT_DESCRIPTION_Exit_Glacier.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
1. CONTRACT ID CODE
N/A
PAGE
2. AMENDMENT/MODIFICATION NO. 3. EFFECTIVE DATE 4. REQUISITION/PURCHASE NO. 5. PROJECT NO. (If applicable)
A001 06/14/2018 N/A See block 14
6. ISSUED BY CODE N/A 7. ADMINISTERED BY (If other than Item 6) CODE N/A
Department of Transportation Federal Highway Administration 610 East Fifth Street Vancouver WA 98661-3801
8. NAME AND ADDRESS OF CONTRACTOR (No., street, county, State and Zip Code) 9A. AMENDMENT OF SOLICITATION NO.
X 69056718B000017
9B. DATED (SEE ITEM 11)
05/18/2018
10A. MODIFICATION OF CONTRACT/ORDER NO.
N/A
10B. DATED (SEE ITEM 13)
CODE: N/A FACILITY CODE: N/A
N/A
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
| X | The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers
(__ ) is extended, ( x ) is not extended.
Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:
(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted; or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
N/A
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS,
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
A THIS CHANGE ORDER IS ISSUED PURSUANT TO (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER NO. IN
ITEM 10A.
N/A
B THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (Such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).
N/A
C THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
N/A
D OTHER (Specify type of modification and authority)
N/A
E. IMPORTANT: Contractor n/a is not, n/a is required to sign this document and return n/a copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
AK NPS KEFJ 10(5), Exit Glacier Road Bridge Rehabilitation
See page 2
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15a. NAME AND TITLE OF SIGNER (Type or print) 15a. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
N/A
15B. CONTRACTOR/OFFEROR 15C. DATE SIGNED 16B. UNITED STATES OF AMERICA 16C. DATE SIGNED
BY_________________________________________ BY N/A___________________________ N/A (Signature of person authorized to sign) (Signature of Contracting Officer)
NSN 7540-01-152-8070
PREVIOUS EDITION NOT USABLE
30-105 STANDARD FORM 30 (REV. 10-83)
Prescribed by GSA
FAR (48 CFR) 53.243
Amendment No. A001, dated 06-14-2018 AK NPS KEFJ 10(5) Solicitation No. 69056718B000017 Exit Glacier Road Bridge Rehabilitation
REVISIONS ARE AS FOLLOWS:
CONTRACT CLAUSES
Page C-92. Adds FAR Clause 52.236-4, Physical Data.
SPECIAL CONTRACT REQUIREMENTS
Page F-3, Subsection 575.04(c), Surface preparation. Deletes reference to reduced duration D4263 test.
PLANS
Plan sheet I.1 Revises Note 4.
ENCLOSURES
Pages:
C-92 F-3
Plan Sheets:
I.1
Physical Data:
Exit Glacier Bridge Inspection 2017.pdf
C-92
Contract Clauses Project: AK NPS KEFJ 10(5), Exit Glacier Road Bridge Rehabilitation
The Federal Highway Administration utilizes the Contractor Performance Assessment Reporting System (CPARS) to record and maintain past performance information. CPARS hosts a suite of web-enabled applications that are used to document contractor performance information that is required by Federal Regulations. The CPARS module assesses performance on contracts for Systems, Services, Information Technology, and Operations Support; Architect-Engineer contracts; and Construction contracts.
Reference material can be accessed in CPARS.
The registration process requires the Contractor to identify an individual that will serve as a primary contact. This individual will be authorized access to the evaluation for review and comment. In addition, the Contractor is encouraged to identify a secondary contact in the event the primary contact is unavailable to process the evaluation within the required 60 day time period. After the FHWA Focal Point registers the contract in CPARS, the contractor representative will receive a system generated email notifying him/her that the contract is registered. A system generated email will also provide the Contractor with a User ID if the person does not already have a CPARS User ID.
After a performance evaluation has been prepared and is ready for comment, the Contractor representative will receive a system generated email notification that the performance evaluation is electronically available for review and comment. The Contractor representative will receive an automated email whenever an assessment is completed and can subsequently retrieve the completed assessment from
CPARS.
Contractors may access evaluations in CPARS for review and comment.
52.236-4 Physical Data (Apr 1984)
Data and information furnished or referred to below is for the Contractor’s information. The Government shall not be responsible for any interpretation of or conclusion drawn from the data or information by the Contractor.
(a) The indications of physical conditions on the drawings and in the specifications are the result of site investigations by: N/A..
(b) Weather conditions: N/A.
(c) Transportation facilities: N/A.
(e) Geotechnical data, design data, and environmental information consisting of the following, will be posted with the solicitation.
(1) Exit Glacier Bridge Inspection 2017
Revised by Amendment A001
F-3 DIVISION 550
Special Contract Requirements Project: AK NPS KEFJ 10(5), Exit Glacier Road Bridge Rehabilitation to 250 psi (1.7 MPa), or a failure area, at a depth of 1/4 inch (6 mm) or more into the base concrete, over at least 50 percent of the test area. Use the test method prescribed in ACI 503R, Appendix A, of the ACI Manual of Concrete Practice to verify adhesion using the proposed cleaning practice (size of shot, flow of shot, forward speed, number of passes of shot-blasting machine and other equipment, and procedures).
A test result shall be the average of three tests on a test patch of not less than 4.5 ft2 (0.4 m2).
One test result shall be obtained for each span or 500 yd2 (420 m2), whichever is the smaller area. The CO will designate the location of the test patches and locate them to provide for the evaluation of the range of surface conditions on the bridge; including at least one test patch on deck repairs. Install test patches at the same thickness and using the same materials, equipment, personnel, timing, sequence of operations, and curing period prior to opening to traffic that will be used for the installation of the overlay. The cleaning practice, materials and installation procedure will be approved if one passing test result is obtained from each test area when tested at an age of 24 hours or more.
If the cleaning practice, materials, and installation procedure are not acceptable, the Contractor shall remove failed test patches, make the necessary adjustments, and test all test areas until satisfactory test results are obtained.
Determine that the deck surface is dry immediately prior to primer application according to ASTM D4263, or by other methods, including a reduced duration D4263 test, as approved by the CO. No visible moisture is to be present on the surface of the concrete at the time of application of the polymer concrete overlay. Apply the primer within 24 hours of cleaning.
Apply the slurry/binder coat while the primer is tacky. If field conditions change to prevent application while primer is still tacky, actions to re-activate the primer may be recommended by the Manufacturer’s Technical Representative and approved by the CO. Remove any contamination of the deck, primer, slurry coat, or seal coat after initial cleaning. Apply the entire system; primer, slurry coat, and seal coat, prior to opening the area to traffic.
(d) Application of epoxy overlay. The overlay primer and binder coats may be mixed by electric drill and jiffy cage-style mixing paddle in buckets, automatic metering continuous mixers, or by other methods suitable for job size and scheduling requirements as provided for in the approved plan. Provide materials to the job site in premeasured packaging. If this is not available, use suitable approved measuring procedures to ensure that the Manufacturer’s recommended mix design is achieved on a consistent basis.
Apply mixed epoxy primer coat with a flat rubber squeegee at a spread rate between 200 and 250 sf/gal (6.14 m2/L) over the prepared deck surface ensuring that all existing deck cracks are sealed. Apply first epoxy binder coat at a nominal thickness of 50 mils or approximately 32 sf/gal (0.79 m2/L) using 3/16 inch (5 mm) notched rubber squeegees. Immediately after placement of the epoxy binder coat, broadcast the approved wearing coarse aggregate to 2 lb/ft2 (10 kg/m2) in such a manner as to cover the base coat uniformly and completely without any epoxy wet spots in the finished surface.
After the first binder coat has cured sufficiently to lock in the wearing coarse aggregate (typically 4 to 6 hours, as recommended by the Manufacturer), remove all loose, excess
Revised by Amendement A001
STRUCTURE SUMMARY STRUCTURE NO. 9845-001P
EXIT GLACIER BRIDGE INSPECTION DATE: 6/11/17
BRIDGE IDENTIFICATION AND DESCRIPTION
MAIN SPAN MATERIAL:
MAIN SPAN TYPE:
# OF BEAMS, MAIN SPAN: ..
DECK TYPE:
WEARING SURFACE:
ABUT. FOUNDATIONS:
PIER FOUNDATION(S):
ABUTMENT / PIER MAT'L: ...
PROJ./PLAN REF. NO:
NPS ROAD CLASS:
STRUCTURE HISTORY:
CONCRETE CONTINUOUS
BOX GIRDER - SINGLE or SPREAD
CONCRETE CAST-IN-PLACE
MONOLITHIC CONCRETE
SPREAD FTG ON BEARING MAT'L / SPRE
SPREAD FOOTING ON PILES
CONCRETE
KEFJ 10-(1) / RG2422
1 - PRINCIPAL PARK ROAD
LOCATION
NO. OF MAIN SPANS:
NO. OF APPR. SPANS:
STRUCT. TOTAL LENGTH: ..
MAX. SPAN LENGTH:
DECK WIDTH:
CURB TO CURB WIDTH:
YEAR BUILT:
YEAR RECONSTRUCTED: ..
SKEW ANGLE:
FRACTURE CRITICAL:
250.0 FT (76.2 M)
125.0 FT (38.1 M)
36.5 FT (11.1 M)
28.0 FT (8.5 M)
N/A
20 °
NO
KENAI FJORDS NATIONAL PARK MILE POINT: ..................... 8.00 (KM PT 12.87)
STATE: ................................. ALASKA LOCATION: 7.5 miles west of Seward Highway (SR 9) on Herman Leirer Road. FACILITY CARRIED: ............ EXIT GLACIER ROAD
FEATURE INTERSECTED: .. RESURRECTION RIVER
STRUCTURE EVALUATION SUMMARY
This concrete box girder bridge is in satisfactory condition overall. There have been no significant changes since the previous inspection.
The main problems requiring attention at this time include a damaged end treatment for the northeast approach guardrail, erosion at the south side of the west approach, and debris accumulation in the deck joints.
It should also be noted that extensive vertical cracking with efflorescence is present on both sides of the box girder.
While not considered a serious problem at this time, this condition will continue to be monitored.
Corrective measures should be taken as outlined in this report to prevent the possible development of more serious or costly problems in the future.
INSPECTION TEAM: B. OLTMANN, J. HENSLEY
CONDITION ASSESSMENT:
BENJAMIN OLTMANN, PE, FIELD TEAM LEADER 360-619-7550
REPORT REVIEW:
MARCUS MILLER, P.E., BRIDGE INSPECTION ENGINEER 703-404-6252
REPORT APPROVAL: DATE: 11/7/17
JORGOMAI CEESAY, PH.D., P.E., BIP SUPERVISORY ENGINEER 703-404-6244
RECOMMENDATIONS AND ESTIMATED COSTS STRUCTURE NO. 9845-001P
A (Critical) - Structure is closed, in imminent danger of collapse, or presents a critical safety hazard.
B (Major) - Structure exhibits severe deterioration, presents a safety hazard, or is designated a high priority due to age and/or condition.
C (Moderate) - Structure is deficient, functionally obsolete, or requires substantial repairs to prevent a serious deficiency or unsafe condition.
D (Minor) - Structure is generally in good condition. Preventative maintenance may be required.
E (Special) - Structure is under construction or reconstruction.
D226 PRIORITY OF IMPROVEMENT
ITEM
NO.
MAINTENANCE RECOMMENDATIONS
(GENERALLY NOT FLHP ELIGIBLE)
QTY. UNIT COST
UNIT
ESTIMATE
COST
PRELIM.
58.2 PERIODICALLY REMOVE GRAVEL AND DEBRIS FROM DECK EXPANSION JOINTS. 1 LS $1,000 $1,000
222.3 REPLACE END TREATMENT ON NORTHEAST APPROACH GUARDRAIL. 1 EA $1,000 $1,000
58.6 CLEAN AND COAT EXPOSED REBAR ON NORTH CONCRETE RAIL POST #37, AND
SPOT PAINT PEDESTRIAN RAILING.
1 LS $1,000 $1,000
222.7 INSTALL OBJECT MARKERS AT APPROACH GUARDRAIL ENDS . 4 EA $250 $1,000
PRELIM. MAINTENANCE TOTAL : $4,000
ITEM
NO.
REHABILITATION/RECONSTRUCTION
(TYPICALLY NEEDED WITHIN 5 YEARS)
QTY. UNIT
UNIT
COST ESTIMATES
PRELIM. COST
REHAB. RECONSTR.
58.1 CLEAN AND SEAL CONCRETE DECK SURFACE TO PREVENT WATER
INTRUSION (HEALER / SEALER).
9,125 SF $6 $55,000 $0
58 CONTRACT COSTS FOR MOBILIZATION, TRAFFIC CONTROL, AND
DESIGN/CONSTRUCTION ENGINEERING.
1 LS $40,000 $40,000 $0
PRELIM. REHABILITATION/RECONSTRUCTION TOTAL : $95,000 $0
PRELIMINARY ESTIMATE TOTAL* : ........................................... $99,000
(*Includes typical contract costs for mobilization, traffic control, and design/construction engineering; but does not include detour bridges, work beyond the bridge limits, or work not listed above. Estimates are approximate and are for preliminary planning purposes only; they should not be used as a complete or final engineers estimate.)
REMARKS: Cracks in the concrete box girder will continue to be monitored.
FIELD INSPECTION REPORT STRUCTURE NO. 9845-001P
G = GOOD (CODES 7 - 9) F = FAIR (CODES 5 - 6) P = POOR (CODES 0 - 4)
CONDITION RATING CODE EQUIVALENTS FOR SUB-ELEMENTS
SERIOUS CONDITION - loss of section, deterioration, spalling, or scour have seriously affected primary structural components. Local failures are possible.
Fatigue cracks in steel or shear cracks in concrete may be present.
CRITICAL CONDITION - advanced deterioration of primary structural elements. Fatigue cracks in steel or shear cracks in concrete may be present or scour may have removed substructure support. Unless closely monitored it may be necessary to close the structure until corrective action can be taken.
“IMMINENT” FAILURE CONDITION - major deterioration or sec ion loss present in critical structural components or obvious vertical or horizontal movement affecting structure stability. Structure is closed to traffic but corrective action may return structure to light service.
FAILED CONDITION - out of service; beyond corrective action.
CONDITION RATING CODES FOR ITEMS 58 - 62, 222, 223
NOT APPLICABLE
EXCELLENT CONDITION
VERY GOOD CONDITION - no problems noted.
GOOD CONDITION - some minor problems.
SATISFACTORY CONDITION - structural elements show some minor deterioration.
FAIR CONDITION - all primary structural elements are sound but may have minor section loss, cracking, spalling, or scour.
POOR CONDITION - advanced section loss, deterioration, spalling, or scour.
N
58. DECK ITEM REFERENCE AND REMARKS
OTHER
ALIGNMENT
DEFLECTION AND/OR VIBRATION
FASCIA(E)
DIAPHRAGMS AND BRACING
TRUSSES
FLOOR BEAMS AND STRINGERS
ARCH(ES) OR SLAB(S)
GIRDERS OR BEAMS
BEARING DEVICES
59. SUPERSTRUCTURE
OTHER
DEFLECTION AND/OR VIBRATION
UTILITIES
DRAINS AND DRAINAGE
PARAPETS AND/OR RAILINGS
CURBS, SIDEWALKS, AND MEDIAN
RIDEABILITY
WEARING SURFACE
EXPANSION JOINTS
DECK SLAB
ABUTMENTS
60. SUBSTRUCTURE
1.
10.
2.
3.
4.
5.
6.
7.
8.
9.
10.
9.
8.
7.
6.
5.
4.
3.
2.
1.
PAINT
11.
G F N N N N N N G
N G
N G G G G G
N
G
G
F
58.1 WIDESPREAD MINOR SCALING OF DECK SURFACE. MINOR
DIAGONAL CRACKING OF DECK AT SOUTHEAST CORNER. MINOR
TRANSVERSE CRACKING OF DECK SURFACE OVER PIER.
WIDESPREAD MINOR TRANSVERSE CRACKING WITH
EFFLORESCENCE ON UNDERSIDE OF DECK OVERHANGS AT PIER.
SEE ALSO 59.2.
58.2 MINOR PONDING OF WATER AT SOUTHWEST CORNER.
58.5 MINOR SPALLING OF UPSTREAM CURB NEAR CENTER OF WEST
SPAN AND SOUTH CURB OF WEST APPROACH. MINOR
TRANSVERSE CRACKING WITH EFFLORESCENCE THROUGHOUT
TOP OF BOTH CURBS. MINOR FLEXURE CRACKING OF SIDEWALK
OVER PIER. MINOR VEGETATION GROWTH ALONG CURBS IN WEST
APPROACH.
58.6 MINOR SNOW PLOW BLADE DAMAGE TO NORTH CONCRETE RAIL
POSTS AND RAILING; REBAR EXPOSED AT POST #37. MINOR
SCRAPE MARK ON SOUTH CONCRETE RAIL BETWEEN POSTS #1
AND #12 AND ON NORTH RAIL BETWEEN POSTS #1 AND #8. MINOR
VERTICAL CRACKING OF CONCRETE RAILINGS IN SEVERAL
LOCATIONS WITH LIGHT EFFLORESCENCE. MINOR SPALL IN
NORTHWEST END PARAPET. MINOR DENT IN VERTICAL BALLASTER
OF PEDESTRIAN RAILING NEAR WEST ABUTMENT WITH FLAKING OF
GALVANIZING COATING AND RUSTING.
58.7 EVIDENCE OF MINOR PONDING ALONG SOUTH CURB WITH MINOR
ACCUMULATION OF DEBRIS ALONG BOTH CURBS.
BREASTWALLS OR COLUMNS 1. F
PILE BENTS 2. N
CAPS AND/OR BEARING SEATS 3. G
BACKWALLS AND/OR BULKHEADS 4. G
FOUNDATIONS 5. G
WINGWALLS 6. G
WEEP HOLES 7. G
EXPANSION JOINTS 8. G
EROSION AND/OR SCOUR 9. G
SETTLEMENT OR DEFLECTION 10. G
SLOPE PROTECTION 11. N
OTHER 12. N
PIER(S)
WALLS AND/OR COLUMNS 13. G
PILE BENTS 14. N
CAPS AND/OR BEARING SEATS 15. N
FOUNDATIONS 16. G
EROSION AND/OR SCOUR 17. F
SETTLEMENT OR DEFLECTION 18. G
OTHER 19. N
ITEM REFERENCE AND REMARKS
STREAM BED COMPOSITION : 9.
AVERAGE CLEAR OPENING 8.
NORMAL VELOCITY 7.
ADEQUACY OF OPENING 6.
OTHER 5.
WATERWAY OBSTRUCTIONS 4.
CHANNEL PROTECTION 3.
EROSION AND/OR SCOUR 2.
ALIGNMENT 1.
61. CHANNEL 6
G F N G N
MED
SUFF
7 FT.
GRAVEL
222. APPROACHES 7
OTHER 9.
ALIGNMENT 8.
SIGNS 7.
SETTLEMENT 6.
EROSION 5.
SURFACING 4.
APPROACH GUARDRAIL 3.
RELIEF JOINTS 2.
1. APPROACH SLABS N
N F G G G N G N
223. RETAINING WALL N
OTHER 6.
SETTLEMENT OR DEFLECTION 5.
EROSION AND/OR SCOUR 4.
FOUNDATION 3.
WEEP HOLES 2.
1. WALL
36. TRAFFIC AND SAFETY FEATURES
APPROACH GUARDRAIL ENDS D.
APPROACH GUARDRAILS C.
TRANSITIONS B.
BRIDGE RAILINGSA. 1
TRAFFIC SAFETY RATING CODES
0 - Does not meet standards or a safety feature is required and none is provided.
1 - Meets currently acceptable standards.
N - Not applicable or a safety feature is not required.
59.2 NUMEROUS VERTICAL HAIRLINE CRACKS WITH MINOR
EFFLORESCENCE AT APPROXIMATELY 18" SPACING ON BOTH SIDES
OF BOX GIRDER NEAR PIER; CRACKS EXTEND INTO OVERHANGS
(SEE 58.1). MINOR HORIZONTAL CRACKING WITH EFFLORESCENCE
AT TOP OF UPSTREAM SIDE OF GIRDER NEAR PIER. VERTICAL
CRACKS IN BOX GIRDER SIDES NEAR MID-SPAN, BOTH SPANS;
EFFLORESCENCE FROM CRACKS ON BOTH SIDES OF EAST SPAN.
HAIRLINE TO MINOR DIAGONAL CRACKING OF BOX GIRDER SIDES
NEAR EAST ABUTMENT. VERTICAL HAIRLINE CRACKS AT 24"
SPACING WITH EFFLORESCENCE NEAR WEST ABUTMENT ON
DOWNSTREAM SIDE.
MINOR RUST STAINING ON BOTTOM OF BOX GIRDER IN A FEW
LOCATIONS, MOST LIKELY FROM REBAR CHAIRS.
60.1 A FEW MINOR VERTICAL CRACKS, FULL HEIGHT ON EAST
ABUTMENT BREASTWALL. MINOR SPALL ON ARCHITECTURAL
TREATMENT AT JUNCTION OF WEST ABUTMENT BREASTWALL WITH
DOWNSTREAM WINGWALL. MODERATE WATER SEEPAGE AT
SOUTH SIDE CHEEK WALL AT WEST ABUTMENT DRAINS ONTO
BEARING SEAT AND DOWN BREASTWALL (NOT OBSERVED THIS
INSPECTION). WATER LEVEL MONITORING STATION AT
DOWNSTREAM SIDE OF EAST ABUTMENT. GRAFFITI ON FACE OF
EAST ABUTMENT BREASTWALL.
60.6,10 TOPS OF WINGWALLS ARE MISALIGNED WITH ABUTMENTS AT
VERTICAL JOINTS, 1-3/4" AT WEST END OF BRIDGE AND 3/4" AT EAST
END, LIKELY FROM CONSTRUCTION.
60.9 MINOR EROSION AT NORTHEAST CORNER OF EAST ABUTMENT.
60.17, 61.2 MODERATE SCOUR AROUND PIER NOTED IN PREVIOUS INSPECTION
REPORT; NO EXPOSED FOOTING, SOUNDED (2017).
MINOR CHANNEL BANK EROSION PRESENT, MAINLY DOWNSTREAM
OF STRUCTURE.
61.1,4,6 BRIDGE OPENING IS MINIMAL DURING FLOODS. SAND BAR
DEPOSITS AT WEST BANK IMMEDIATELY DOWNSTREAM; DEPOSITS
ARE PRIMARILY DUE TO ALIGNMENT OF MAIN CHANNEL AND
SECONDARILY DUE TO TRIBUTARY DOWNSTREAM OF WEST SPAN.
222.3 MODERATE VEHICLE SCRAPES ON APPROACH GUARDRAILS;
SEVERAL MISSING BOLTS AT RAILING TRANSITIONS, EAST END OF
BRIDGE. MODERATE DAMAGE TO SEVERAL SPACERS IN EAST
APPROACH GUARDRAIL, DOWNSTREAM SIDE; SEVERAL BULLET
HOLES ALSO PRESENT IN END TREATMENT. VEHICLE DAMAGE TO
EAST APPROACH UPSTREAM GUARDRAIL END TREATMENT.
222.4,7 POST HOLES FOR GATE IN PAVEMENT AT EAST APPROACH.
NO OBJECT MARKERS PRESENT.
ADDITIONAL ITEM REFERENCE AND REMARKS
222.5,6 MINOR SETTLEMENT OF EAST APPROACH PAVEMENT.
STRUCTURE LOAD RATING STRUCTURE NO. 9845-001P
TRUCK TYPE
INVENTORY RATING (NORMAL TRAFFIC) OPERATING RATING (MAXIMUM LOAD)
TONS METRIC TONS TONS METRIC TONS
H 26 23 38 34
HS 45 40 68 61
TYPE 3 43 39 68 62
TYPE 3S2 50 45 80 73
TYPE 3-3 55 49 87 79
DESIGN LOADING: HS20 (MS18)
X CAPACITY MEETS OR EXCEEDS DESIGN LOAD
CAPACITY IS LESS THAN DESIGN LOAD
X ORIGINAL LOAD RATING CALCULATION APPLICABLE
ORIGINAL LOAD RATING CALCULATION REVISED
DATE OF LOAD RATING CALCULATION: 12/93
LOAD RATING CONTROLLED BY: MOMENT CAPACITY OF BOX GIRDER
REMARKS:
STRUCTURE INVENTORY AND APPRAISAL STRUCTURE NO. 9845-001P
STRUCTURE IDENTIFICATION
(201) PARK: KENAI FJORDS NATIONAL PARK
(202) STRUCTURE NAME: .......... EXIT GLACIER BRIDGE
(203) STRUCTURE KIND: ............ 1 - BRIDGE
(204) STRUCTURE NUMBER: ..... 9845-001P
(205) NPS REGION: .................... 7 - ALASKA
(206) ROUTE CODE NUMBER: ... 10
(207) ROAD SECTION NO: .......... 001P
(208) NPS ROAD CLASS: ............ 1 - PRINCIPAL PARK ROAD
(209) WITHIN NPS BNDRY?: ....... YES
(210) OPERATING UNIT: ............. PARK
(211) PROJECT NO(S): ................ KEFJ 10-(1)
(212) DRAWING NUMBERS: ....... RG2422
(21) MAINTAINED BY: ................. 66 - NATIONAL PARK SERVICE
(22) OWNER: ............................... 66 - NATIONAL PARK SERVICE
(1) STATE:
(2) STATE HWY. AGENCY DIST:
(3) COUNTY CODE:
(4) CITY/PLACE CODE:
(5) INVENTORY ROUTE:
(6) FEATURES INTERSECTED:
(7) FACILITY CARRIED:
(8) STATE STRUCTURE NO:
(9) LOCATION:
(10) INV. RTE. - MIN. VERT. CLR: ..
(11) MILE POINT:
(27) YEAR BUILT:
(106) YEAR RECONSTRUCTED:
(20) TOLL:
(37) HISTORICAL DESIGNATION: ..
020 - ALASKA (AK)
122 - KENAI PENINSULA
161000000
RESURRECTION RIVER
EXIT GLACIER ROAD
9845001P0000000
7.5 miles west of Seward
99.99 FT (99.99 M)
8.00 (KM PT 12.87)
N/A
3 - FREE ROAD
5 - NOT ELIGIBLE
STRUCTURE DESCRIPTION, FOUNDATION, AND DECK TYPE
(43A) MAIN STR. MATERIAL: ..
(43B) MAIN STR. TYPE:
(45) NO. OF MAIN SPANS:
(48) MAX. SPAN LENGTH:
(49) STRUCTURE LENGTH:
(216A) ABUTMENT #1 FDN:
(216B) ABUTMENT #2 FDN:
(217A) PREDOM. PIER FDN.: ..
(217B) SECOND. PIER FDN: ...
(107) DECK TYPE:
2 - CONCRETE CONTINUOUS
06 - BOX GIRDER - SINGLE or SPREAD
125.0 FT (38.1 M)
250.0 FT (76.2 M)
2 - SPREAD FTG ON BEARING MAT'L
3 - SPREAD FOOTING ON PILES
3 - SPREAD FOOTING ON PILES
6 - N/A
1 - CONCRETE CAST-IN-PLACE
(44A) APPR. STR. MATERIAL: ........ 0 - OTHER
(44B) APPR. STR. TYPE: ................ 00 - OTHER
(46) NO. OF APPROACH SPANS: .. 0
(108) WEAR SURFACE/PROTECT SYSTEM:
A) TYPE WEARING SURFACE: .. 1 - MONOLITHIC CONCRETE
B) TYPE MEMBRANE: ................. 0 - NONE
C) TYPE PROTECTION: .............. 0 - NONE
(218) IS SALT USED?: ..................... NO
LOAD RATING AND POSTING
(31) DESIGN LOAD: ................. 5 - HS20 (MS18) (41) LOAD RESTRICTION: ......... A - OPEN, NO RESTRICTION
(66) INVENTORY RATING: ...... 45.0 TONS (40.0 METRIC TONS) (70) BRIDGE POSTING: .............. 5 - NO POSTING REQUIRED
(64) OPERATING RATING: ...... 68.0 TONS (61.0 METRIC TONS)
INSPECTION DATES
(90) INSPECTION DATE: 6/17 (91) FREQ. OF INSP: 24 MONTHS (92 / 93) CRITICAL FEATURE INSPECTION (CFI):
(219) ADD. STUDIES NEEDED: N - 0 - NONE (A) FRACTURE CRITICAL: ... NO
INSP. EVERY: MONTHS - LAST INSP. : (220) SPECIAL STUDY TYPE: 0 - NONE
(B) UNDERWATER: .............. NO
(221) SPECIAL STUDY DATE: INSP. EVERY: MONTHS - LAST INSP. :
(C) SPECIAL INSPECTION: .. NO
INSP. EVERY: MONTHS - LAST INSP. :
STRUCTURE INVENTORY AND APPRAISAL STRUCTURE NO. 9845-001P
GEOMETRY, TRAFFIC, AND NAVIGATIONAL DATA
(16) LATITUDE: ............................. 60°11'41.30" (51) CURB TO CURB WIDTH: ........... 28.0 FT (8.5 M)
(17) LONGITUDE: ......................... 149°35'19.10" (52) DECK WIDTH: ............................ 36.5 FT (11.1 M)
(19) DETOUR LENGTH: ............... 199 MI (199 KM) (32) APPR. ROADWAY WIDTH: ........ 28.0 FT (8.5 M)
(28A) LANES ON STRUCT: .......... 02 (213) APPR. PAVEMENT WIDTH: ..... 28.0 FT (8.5 M)
(28B) LANES UNDER STRUCT: ... 00 LEFT SHOULDER: .................. 0.0 FT (0.0 M)
(42A) SERVICE ON: ..................... 1 - HIGHWAY RIGHT SHOULDER: ................ 0.0 FT (0.0 M)
(42B) SERVICE UNDER: .............. 5 - WATERWAY (33) BRIDGE MEDIAN: ....................... 0 - NO MEDIAN
(29) AVG. DAILY TRAFFIC: .......... 200 (34) SKEW ANGLE: ............................ 20 °
(30) YEAR OF ADT: ...................... 2013 (35) DECK FLARE?: ........................... NO
(114) FUTURE ADT: ..................... 500 (47) TOTAL HORIZ. CLEARANCE: .... 28.0 FT (8.5 M)
(115) YEAR OF FUTURE ADT: ..... 2033 (50) SIDEWALKS:
(101) PARALLEL STRUCTURE: ... N - NONE LEFT : ...................................... 1.8 FT (0.5 M)
(38) NAVIGATION CONTROL?: ... 0 RIGHT : ................................... 6.8 FT (2.1 M)
(39) VERTICAL CLEARANCE: ...... 0.0 FT (0.0 M) (214) BRIDGE RAIL TYPE:
(40) HORIZ. CLEARANCE: ........... 0.0 FT (0.0 M) RAIL CONFIGURATION: ......... 1 - FULL HEIGHT (NO PARAPE
(111) ABUT. OR PIER PROT: ....... MATERIAL: .............................. 1 - CONCRETE
DESIGN TYPE: ........................ 1 - CONTINUOUS RAIL
LATERAL UNDERCLEARANCE:
(55) RIGHT: ....................... 0.0 FT (0.0 M) (215) BRIDGE RAIL HEIGHT: ............ 2.25 FT (0.69 M)
(56) LEFT: ......................... 0.0 FT (0.0 M) (53) MIN. VRT. CLEAR. OVER DECK: 99.99 FT (99.99 M)
(54) MIN. VRT. UNDERCLEARANCE: 0.00 FT (0.00 M)
CONDITION AND APPRAISAL DATA, PROPOSED IMPROVEMENTS, AND COST
(58) DECK:
(59) SUPERSTRUCTURE:
(60) SUBSTRUCTURE:
(61) CHANNEL:
(62) CULVERT: ........................... N
(222) APPROACHES:
(223) RETAINING WALL: ........... N
(36) TRAFFIC SAFETY FEAT: ... 1111
(75A) TYPE OF WORK:
(75B) WORK DONE BY:
(76) IMPROVEMENT LENGTH: ..
(67) STRUCTURAL EVALUATION:
(68) DECK GEOMETRY:
(69) UNDERCLEARANCES:
(71) WATERWAY ADEQUACY:
(72) APPROACH ALIGNMENT:
(113) SCOUR CRITICAL:
(225) PURPOSE OF IMPROVEMENT:
(226) PRIORITY OF IMPROVEMENT:
(227) MAINTENANCE COST:
(228) REHAB./RECONSTR. COST: ...
(229) CONSTRUCTION COST:
N
5 - Stable; scour within limits of
2 - REHAB/RECONSTRUCTION
D - MINOR
$4,000
$95,000
$0
ADDITIONAL INFORMATION
(230) STRUCTURE HISTORY:
(231) ADDITIONAL CONSIDERATIONS:
OPTIMAL INSPECTION CONDITIONS ARE IN MID-MAY.
(330) ADDITIONAL CONFIG. INFO.:
SPAN LENGTH = 122.6', BOTH SPANS.
http:149�35'19.10 http:60�11'41.30
APPENDIX STRUCTURE NO. 9845-001P
PHOTOGRAPHS STRUCTURE NO. 9845-001P
PHOTO #1 - LOOKING WEST
FLOW
PHOTO #2 - SOUTH (DOWNSTREAM) SIDE
PHOTO #3 - GENERAL TOPSIDE VIEW
PHOTO #4 - GENERAL TOPSIDE VIEW LOOKING EAST
PHOTO #5 - GENERAL TOPSIDE VIEW LOOKING WEST
PHOTO #6 - TYPICAL VIEW OF EAST EXPANSION JOINT
PHOTO #7 - PONDING AT WEST EXPANSION JOINT ON DOWNSTREAM
SIDE
PHOTO #8 - TYPICAL VIEW OF DOWNSTREAM RAILING
PHOTO #9 - TYPICAL VIEW OF UPSTREAM RAILING (NOTE PEDESTRIAN
RAILING ATTACHED TO TOP OF BRIDGE RAILING)
PHOTO #10 - EXPOSED REBAR IN UPSTREAM RAILING POST #37
PHOTO #11 - SNOW PLOW DAMAGE TO DOWNSTREAM RAILING NEAR
EAST ABUTMENT
PHOTO #12 - SNOW PLOW DAMAGE TO DOWNSTREAM RAILING
PHOTO #13 - DENT IN VERTICAL BALUSTER FOR PEDESTRIAN RAILING
ON NORTH SIDE NEAR WEST ABUTMENT; NOTE FLAKING OF
GALVANIZING COATING AND RUSTING OF STEEL
PHOTO #14 - VERTICAL CRACKING WITH EFFLORESCENCE ON
UPSTREAM SIDE OF BOX GIRDER NEAR PIER
PHOTO #15 - VERTICAL CRACKING AND EFFLORESCENCE EXTENDING
INTO DECK OVERHANG ON UPSTREAM SIDE OF BOX GIRDER NEAR
PIER
PHOTO #16 - VERTICAL CRACKING WITH EFFLORESCENCE ON
DOWNSTREAM SIDE OF BOX GIRDER NEAR PIER
PHOTO #17 - GENERAL UNDERSIDE VIEW, EAST SPAN LOOKING EAST
PHOTO #18 - GENERAL UNDERSIDE VIEW, WEST SPAN LOOKING WEST
PHOTO #19 - GENERAL VIEW OF EAST ABUTMENT
PHOTO #20 - GENERAL VIEW OF WEST ABUTMENT
PHOTO #21 - GENERAL VIEW OF PIER
PHOTO #22 - HAIRLINE VERTICAL CRACKING ON DOWNSTREAM SIDE
OF BOX GIRDER NEAR WEST ABUTMENT
PHOTO #23 - MISALIGNMENT OF WEST ABUTMENT DOWNSTREAM
WINGWALL
PHOTO #24 - GENERAL VIEW OF EAST ABUTMENT BEARING SEAT
PHOTO #25 - EAST APPROACH
PHOTO #26 - WEST APPROACH
PHOTO #27 - VEHICLE DAMAGE TO END TREATMENT FOR UPSTREAM
GUARDRAIL AT EAST APPROACH
PHOTO #28 - VEHICLE SCRAPES AND DAMAGE TO UPSTREAM
GUARDRAIL AT EAST APPROACH
PHOTO #29 - VIEW FROM BRIDGE LOOKING UPSTREAM
PHOTO #30 - VIEW FROM BRIDGE LOOKING DOWNSTREAM
File details come from the government source that posted it.