2-HRG Turtle Creek Road Bridge Drawings.pdf

PDF 530 KB Posted

Attached to
REBID Turtle Creek Road Bridge Reinforced Concrete Deck System with Barrier Curb
Solicitation number
US.199331
Issued by
Union County, Pennsylvania

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

F I L

E N

A M

E

A

U G

P L

O T

T E

D

P

\0

\O

R D

\B R

I D

G E

\b

G P

.d g n

T

I M

E

U

S E

R

P L

O T

D R

I V

E R

P L

T D

R V

L

P

E N

T B

L S

P

E N

T A

B L

E

REVISIONS

Mark By Chk'd. DateDescription

REVISIONS

Mark By Chk'd. DateDescription

REVISIONS

Mark By Chk'd. DateDescription

DEPARTMENT OF TRANSPORTATION

COMMONWEALTH OF PENNSYLVANIA

SHEET OF

Recm'd.

BRIDGE REPLACEMENT

GENERAL PLAN

UNION COUNTY

OVER TURTLE CREEK

50'-0" SIMPLE SPAN ROLLED GIRDER BRIDGE

TURTLE CREEK ROAD STA. 12+02.00

EAST BUFFALO TOWNSHIP

DES: CKD:TJC DWG: GPR TJC

38'-8" OPENING

46'-0" � BRG. TO � BRG.

50'-0" OVERALL LENGTH

� BRG. ABUT. 1 � BRG. ABUT. 2

TYPICAL SECTION

PLAN

ELEVATION

38'-8" OPENING

50'-0" OVERALL LENGTH

HORIZONTAL DATA

BRIDGE ON TANGENT

VERTICAL DATA

PROPOSED CONTOUR

EXISTING CONTOUR

TRAFFIC DIRECTION

LEGEND

DESIGN FLOOD:

HYDRAULIC DATA

100 YR. FLOOD:

FREQUENCY = 25 YEARS

FLOOD OF RECORD: N/A

MAGNITUDE = 1,030 CFS

VELOCITY = 6.47 FPS

ELEVATION = 497.30

MAGNITUDE = 1,620 CFS

VELOCITY = 8.64 FPS

ELEVATION = 501.11

DRAINAGE AREA = 7.83 SQ. MI.

BOT. R.S.F. EL. 482.00 � (TYP.)

4 EQUAL SPACES AT 5'-9 " = 23'-3"

ROLLED GIRDER SUPERSTRUCTURE

HERBERT, ROWLAND AND GRUBIC INC.

PREPARED BY

369 EAST PARK DRIVE

HARRISBURG, PA 17111

SUPPLEMENTAL DRAWINGS

DATE

BACKFILL AT STRUCTURES

DESCRIPTIONDESCRIPTION

GUIDE RAIL TO BRIDGE BARRIER TRANSITIONS

CLASSIFICATION OF EARTHWORK FOR STRUCTURES

REINFORCEMENT BAR FABRICATION DETAILS

ANCHOR SYSTEMS

BC-736M

BC-734M

RC-12M

RC-50M

DWG. NO.

BC-732MPERMANENT METAL DECK FORMS

12/18/24

06/01/10RC-11M

BC-752MCONCRETE SLAB DETAILS

BC-706M

11/01/22

INDEX OF DRAWINGS

TITLE

GENERAL NOTES

SLAB SECTION AND DETAILS3

SHEET NUMBER

GENERAL PLAN

TYPE 31 STRONG POST GUIDE RAIL RC-51M 12/18/24 RECOMMENDED

DISTRICT BRIDGE ENGINEER

46'-0" � BRG. TO � BRG.

25'-9 4"

OUT-TO-OUT

22'-8"

� TURTLE

CREEK ROAD

RAIL TO RAIL

FINISHED

SLOPE

STREAMBED

EL. �489.00

GRS WALL

CMU BLOCK

FACE (TYP.)

1.5

2 0 2 4 FEET

2 0 4 8 FEET

2 0 4 8 FEET

GUIDE RAIL

(ROADWAY ITEM)

(TYP.)

GUIDE RAIL

(ROADWAY ITEM)

(TYP.)

T U

R T

L E

C R

E E

K

SELECTED BORROW EXCAVATION ROCK,

CLASS R-8 CHOKED WITH R-4

(ROADWAY ITEM) (TYP.)

R A

I L

T O

R A

I L

WING D

WING A

WING C

� TURTLE CREEK ROAD

WING B

STA. AHEAD

O.F. BARRIER

O.F. BARRIER

(ROADWAY ITEM)

TO BE REMOVED

EXIST. STRUCTURE

� BRGS.

ABUT. 2

� BRGS.

ABUT. 1

NORMAL WATER

EL. � 492.00

PA 3-RAIL BRIDGE

BARRIER (TYP.)

8" MIN. CONCRETE

DECK

T

Y P

.)2

T

Y P

O U

T -T

O -O

U T

W12x210 (TYP.)

1'-6⅞" 1'-6⅞"

3.0% 3.0%

� BRGS. ABUT. 1

STA. 11+79.00

ELEV. 497.96

BEGIN STRUCTURE

STA. 11+77.00

ELEV. 497.97

� BRIDGE

STA. 12+02.00

ELEV. 497.85

� BRGS. ABUT. 2

STA. 12+25.00

ELEV. 497.73

END STRUCTURE

STA. 12+27.00

ELEV. 497.72

PROPOSED LOW CHORD EL. 495.49

EXISTING LOW CHORD EL. 496.12PROPOSED HIGH CHORD EL. 500.24

EXISTING LOW CHORD EL. 500.72

EXISTING WATERWAY OPENING: 139.43 SF

EXISTING LOW CHORD: EL. 496.12

EXISTING STREAMBED: EL. 489.00

EXISTING SPAN (CLEAR NORMAL): 19.58'

EXISTING HIGH CHORD: EL. 500.72

PROPOSED WATERWAY OPENING: 259.00 SF

PROPOSED LOW CHORD: EL. 495.49

PROPOSED STREAMBED: EL. 489.00

PROPOSED SPAN (CLEAR NORMAL): 38.67'

PROPOSED HIGH CHORD: EL. 500.24

ON TANGENT

-0.50% (STA. AHEAD)

25 YR. FLOOD

EL.497.30

100 YEAR FLOOD

EL. 501.11

DATUM: 480.00

SELECTED BORROW EXCAVATION

ROCK, CLASS R-8 CHOKED WITH

R-4 (ROADWAY ITEM) (TYP.)

11/23/22

02/19/21

11/23/22

10/07/24PA 3-RAIL BRIDGE BARRIER

11/23/22

ROCK, CLASS R-4

(ROADWAY ITEM) (TYP.)

GUIDE RAIL (TYP)

ENGINEER

PROFESSIONAL

REGISTERED

M

N

E P

N

S Y VL

A

A I

N

O

M

O C

T

EWN LA

O

H

F

TUCKER CORL

PE092836

08/11/2025

F I L

E N

A M

E

M

A R

:0

P

L O

T T

E D

P

\0

\O

R D

\B R

I D

G E

\b G

N .d g n

T

I M

E

U

S E

R

P L

O T

D R

I V

E R

P L

T D

R V

L

P

E N

T B

L S

P

E N

T A

B L

E

REVISIONS

Mark By Chk'd. DateDescription

REVISIONS

Mark By Chk'd. DateDescription

REVISIONS

Mark By Chk'd. DateDescription

DEPARTMENT OF TRANSPORTATION

COMMONWEALTH OF PENNSYLVANIA

SHEET OF

Recm'd.

BRIDGE REPLACEMENT

GENERAL NOTES

UNION COUNTY

OVER TURTLE CREEK

50'-0" SIMPLE SPAN ROLLED GIRDER BRIDGE

TURTLE CREEK ROAD STA. 12+02.00

EAST BUFFALO TOWNSHIP

RECOMMENDED

P2016-13 VEHICLES.

OPERATING RATINGS FOR THE H20, HS20, ML80, TK-527, AND P-82 OR

THE PRE-FABRICATED STEEL SUPERSTRUCTURE SHALL BE ANALYZED TO MEET THE

DESIGN IS IN ACCORDANCE WITH THE LRFD METHOD.

LIVE LOAD DISTRIBUTION IS BASED UPON DM-4 DISTRIBUTION FACTOR METHOD.

SUPPLEMENTED BY DESIGN MANUAL PART 4, DECEMBER 2019 EDITION.

AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS 8TH EDITION 2017, AND AS

DESIGN SPECIFICATIONS:

MANUFACTURER RECOMMENDATIONS AND SPECIFICATIONS.

ERECT AND INSTALL THE PRE-FABRICATED STEEL SUPERSTRUCTURE IN ACCORDANCE WITH

ALL FABRICATED STRUCTURAL STEEL TO BE 50 KSI.

DELIVERED TO THE SITE BY OTHERS.

ALL ITEMS FOR THE PRE-FABRICATED STEEL SUPERSTRUCTURE TO BE FABRICATED AND

DECK AND CURBS.

REINFORCING AND BE RESPONSIBLE FOR THE CONSTRUCTION OF THE CAST-IN-PLACE CONCRETE

STEEL SUPERSTRUCTURE MANUFACTURER. THE CONTRACTOR SHALL PROVIDE THE CONCRETE AND

ASSEMBLY HARDWARE, AND MOUNTING HARDWARE TO BE PROVIDED BY THE THE PRE-FABRICATED

RAIL ENDS, SPLICE TUBES, RAIL END CAPS, POSTS, POST PLATES, WOOD BLOCK OUTS,

PERMANENT METAL DECK FORMS, PENNDOT TYPE 3 BRIDGE RAILING CONSISTING OF RAILING,

WHO SEALED THE GRS ABUTMENT DRAWINGS PRIOR TO THE WORK BEING PERFORMED.

DETAILS AS SHOWN ON THESE DRAWINGS SHOULD FIRST BE APPROVED BY THE ENGINEER-OF-RECORD

BE CONSTRUCTED IN ACCORDANCE WITH THESE DRAWINGS. ANY DEVIATIONS FROM CONSTRUCTION

GRS ABUTMENT DRAWINGS ARE PROVIDED BY ETA, INC (5 SHEETS). THE GRS ABUTMENTS SHALL

ACCORDANCE WITH PUBLICATION 408/2020, SECTIONS 105.06 AND 107.12.

COORDINATE, LOCATE, AND CONDUCT ALL WORK RELATED TO PUBLIC AND PRIVATE UTILITIES IN

(814) 359-5250

BELLEFONTE, PA 16823

595 ROLLING RIDGE DRIVE

NORTHCENTRAL REGION

COOPERATE WITH FISH COMMISSION DURING CONSTRUCTION.

NOTIFY THE REGIONAL HEADQUARTERS OF THE FISH COMMISSION PRIOR TO CONSTRUCTION AND

DECK SLAB THICKNESS INCLUDES A 0.5" INTEGRAL WEARING SURFACE.

SUPERSTRUCTURE DIMENSIONS ARE SHOWN FOR A NORMAL TEMPERATURE OF 68 DEGREES F.

ALL DIMENSIONS SHOWN ARE HORIZONTAL, EXCEPT AS NOTED.

CHAMFER EXPOSED CONCRETE EDGES 3/4 IN BY 3/4 IN, EXCEPT AS NOTED.

USE EPOXY-COATED REINFORCEMENT BARS IN ALL COMPONENTS UNLESS OTHERWISE NOTED.

USE RETARDER ADMIXTURE CONFORMING TO PUBLICATION 408/2020 IN THE CONCRETE DECK SLAB.

USE REMOVABLE FORMS TO CONSTRUCT BEAM SEAT.

PREPARE BEARING AREAS AS SPECIFIED IN PUBLICATION 408, SECTION 1001.3.(K)9.

RAKE-FINISH ALL HORIZONTAL CONSTRUCTION JOINTS, EXCEPT AS INDICATED.

SPECIFIED.

WELDING OF REINFORCEMENT STEEL DURING FABRICATION OR CONSTRUCTION IS NOT PERMITTED UNLESS

SPECIFIED.

WELDING OF REINFORCEMENT BARS DURING FABRICATION OR CONSTRUCTION IS NOT PERMITTED UNLESS

AREA, IF APPROVED BY THE ENGINEER. DO NOT USE RAIL STEEL A 996 REINFORCEMENT BARS.

REINFORCING STEEL BARS MAY BE SUBSTITUTED WITH A PROPORTIONAL INCREASE IN CROSS-SECTIONAL

OR A 706. DO NOT WELD GRADE 60 REINFORCING STEEL BARS UNLESS SPECIFIED. GRADE 40

PROVIDE GRADE 60 REINFORCING STEEL BARS THAT MEET THE REQUIREMENTS OF ASTM A 615, A 996, COST TO THE OWNER IF APPROVED BY THE ENGINEER.

A HIGHER CLASS CONCRETE MAY BE SUBSTITUTED FOR A LOWER CLASS CONCRETE AT NO ADDITIONAL

USE CLASS AA CEMENT CONCRETE IN: CURBS/BARRIERS.

USE CLASS AAAP CEMENT CONCRETE IN: DECK SLAB.

PROVIDE 2" CONCRETE COVER ON REINFORCEMENT BARS, EXCEPT AS NOTED.

STATIONS AND ELEVATIONS ARE GIVEN IN FEET UNLESS OTHERWISE NOTED.

ENGINEER PRIOR TO THE WORK BEING PERFORMED.

FROM CONSTRUCTION DETAILS AS SHOWN ON THESE PLANS SHOULD FIRST BE APPROVED BY THE

PRE-FABRICATED STEEL SUPERSTRUCTURE BY TOWNSHIP MAINTENANCE FORCES. ANY DEVIATIONS

THESE PLAN SHEETS WERE PREPARED TO ASSIST IN THE CONSTRUCTION OF GRS ABUTMENTS AND

AASHTO/AWS D1.5M/D1.5 2020 BRIDGE WELDING CODE, AND CONTRACT SPECIAL PROVISIONS.

PROVIDE MATERIALS AND PERFORM WORK IN ACCORDANCE WITH SPECIFICATIONS, PUBLICATION 408/2020, GENERAL NOTES

.0

L

.1

L

.2

L

.3

L

.4

L

.5

L

.6

L

.7

L

.8

L

.9

L

.0

L GUTTER LINE

LEFT

BRIDGE

BEGIN

ABUT. 1

� BRG.

GUTTER LINE

RIGHT

ABUT. 2

� BRG.

BRIDGE

END

TOP OF DECK ELEVATIONS

LOCATION LT. GUTTER P.G. RT. GUTTER

END BRIDGE

1.0L

0.9L

0.8L

0.7L

0.6L

0.5L

0.4L

0.3L

0.2L

0.1L

0.0L

BEGIN BRIDGE

497.38

497.39

497.41

497.43

497.46

497.48

497.50

497.53

497.55

497.57

497.59

497.62

497.63

497.72

497.73

497.75

497.78

497.80

497.82

497.85

497.87

497.89

497.91

497.94

497.96

497.97

497.38

497.39

4967.41

497.43

497.46

497.48

497.50

497.53

497.55

497.57

497.59

497.62

497.63

CONSTRUCTION SPECIFICATIONS

GENERAL

UTILITIES

GRS ABUTMENTS

PRE-FABRICATED STEEL SUPERSTRUCTURE

DES: DWG:TJC JPD CKD: TJC

ENGINEER

PROFESSIONAL

REGISTERED

M

N

E P

N

S Y VL

A

A I

N

O

M

O C

T

EWN LA

O

H

F

TUCKER CORL

SLAB SECTION

#6

½

2'-6"

11" 8" 8" 3"

SECTION C-C

A

A

8" ⅝

7"

4" 4"

1¾" (TYP)

� POST � POST � POST

8" ⅝

4"

1¾" (TYP)

� POST

4"

TYPICAL BARRIER ELEVATION

½

2'-6"

11"8"8"3"

SECTION B-B

CCB B

SECTION A-A

2'-1"

8½"

12 0 12 INCHES

6 0 6 12 INCHES6 0 6 12 INCHES

6 0 6 INCHES

F

IL

E N

A M

E

-A

U G

-2

:4

P

L O

T T

E D

P

\0

\O

R D

\B R

ID

G

E \b

D

E T

.d g n

T

IM

E

U

S E

R

P L O

T D

R

IV

E R

P

L T

D R

V L

P

E N

T B

L S

P

E N

T A

B L E

REVISIONS

Mark By Chk'd. DateDescription

REVISIONS

Mark By Chk'd. DateDescription

REVISIONS

Mark By Chk'd. DateDescription

DEPARTMENT OF TRANSPORTATION

COMMONWEALTH OF PENNSYLVANIA

SHEET OF

Recm'd.

BRIDGE REPLACEMENT

SLAB SECTION AND DETAILS

UNION COUNTY

OVER TURTLE CREEK

50'-0" SIMPLE SPAN ROLLED GIRDER BRIDGE

TURTLE CREEK ROAD STA. 12+02.00

EAST BUFFALO TOWNSHIP

DES: CKD:TJC DWG: JPD TJC

RECOMMENDED

7"

4"4"

� TURTLE

CREEK ROAD

PA 3-RAIL BRIDGE

BARRIER (TYP.)

(TYP.)

W12x210

3.0% 3.0%

1 0 1 2 FEET

8"

W6X20

1'-6⅞"

1'-6"

¾"X¾" CHAMFER

(TYP)

HSS 4"x3"

RAIL TUBE

(TYP)

⅝" DIA ROUND HEAD

BOLT WITH HEX NUT

⅞" ASTM A449 OR F1554, GRADE 105,

GALV ANCHOR BOLTS W/ LEVELING NUTS,

PLAIN WASHERS AND HEX NUTS

1" BASE �

CURB

6"x6"x1'-10"

WOOD BLOCK

1'-6"

2" CLR

1'- 4½ "

1'-4"

GUTTER LINE

4"

C U

R B

3" 2 SPA

@ 9"

2 SPA

@ 9"

2'-6"

2 SPA

@ 9"

2 SPA

@ 9"

2'-6"8 SPA. @ 5'-7½" = 45'-0"

(POST SPACING)

GUTTER LINE

1'-6"

TOP OF

RAIL

REINFORCED CONCRETE

DECK SLAB

REINFORCED

CONCRETE

CURB

2 EQ. SPA.

2 SPA @ 8"

=1'-4"

2 EQ. SPA.

#4

1'-6"

2" CLR

1'-4½ "

1'-4"

GUTTER LINE

#4

� POST

#6

#4 (TYP.)

50'-0"

4"

C U

R B

#6

2" CLR.

(TYP.)

2" C L R

#5 @ 5½" (BUNDLE WITH

TOP TRANSVERSE BARS)

(TYP.)

#5 @ 5½"

#5 @ 7"

½

C

L R

C

L R

#5 @ 5½" (BUNDLE WITH

TOP TRANSVERSE BARS)

(TYP.)

#4 (SEE TYPICAL BARRIER

ELEVATION FOR SPACING)

EPOXY COAT ALL REINFORCEMENT.

#5 @ 10" (EACH BAY)

3" (TYP.)

3"

1'-6"

2 SPA @ 8"

=1'-4"

#6 #6

(EACH BAY)

#4 @ 12" MAX.

NOTE:

2'-6"

T Y

P

⅜

T

Y P

1'-6⅞" 1'-6⅞"

" = 23'-3"¾4 EQ. SPA. @ 5'-9

ROLLED GIRDER SUPERSTRUCTURE

25'-9¾"

OUT-TO-OUT

22'-8"

RAIL TO RAIL

⅜

� POST

EQ. SPA.

3-#5 @

EQ. SPA.

3-#4 @

EQ. SPA.

3-#5 @

EQ. SPA.

3-#4 @

CONCRETE DECK

8" MIN.

(TYP.)

1'-0"

#3 @ 14"*

2-#4*

*PROVIDE HAUNCH REINFORCEMENT WHEN HAUNCH THICKNESS IS 3" OR GREATER

1" CLR.

ENGINEER

PROFESSIONAL

REGISTERED

M

N

E P

N

S Y VL

A

A I

N

O

M

O C

T

EWN LA

O

H

F

TUCKER CORL

b00029240452GN
b00029240452DET

File details come from the government source that posted it. Updated .