2-HRG Turtle Creek Road Bridge Drawings.pdf
PDF 530 KB Posted
- Solicitation number
- US.199331
- Issued by
- Union County, Pennsylvania
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
F I L
E N
A M
E
A
U G
P L
O T
T E
D
P
\0
\O
R D
\B R
I D
G E
\b
G P
.d g n
T
I M
E
U
S E
R
P L
O T
D R
I V
E R
P L
T D
R V
L
P
E N
T B
L S
P
E N
T A
B L
E
REVISIONS
Mark By Chk'd. DateDescription
REVISIONS
Mark By Chk'd. DateDescription
REVISIONS
Mark By Chk'd. DateDescription
DEPARTMENT OF TRANSPORTATION
COMMONWEALTH OF PENNSYLVANIA
SHEET OF
Recm'd.
BRIDGE REPLACEMENT
GENERAL PLAN
UNION COUNTY
OVER TURTLE CREEK
50'-0" SIMPLE SPAN ROLLED GIRDER BRIDGE
TURTLE CREEK ROAD STA. 12+02.00
EAST BUFFALO TOWNSHIP
DES: CKD:TJC DWG: GPR TJC
38'-8" OPENING
46'-0" � BRG. TO � BRG.
50'-0" OVERALL LENGTH
� BRG. ABUT. 1 � BRG. ABUT. 2
TYPICAL SECTION
PLAN
ELEVATION
38'-8" OPENING
50'-0" OVERALL LENGTH
HORIZONTAL DATA
BRIDGE ON TANGENT
VERTICAL DATA
PROPOSED CONTOUR
EXISTING CONTOUR
TRAFFIC DIRECTION
LEGEND
DESIGN FLOOD:
HYDRAULIC DATA
100 YR. FLOOD:
FREQUENCY = 25 YEARS
FLOOD OF RECORD: N/A
MAGNITUDE = 1,030 CFS
VELOCITY = 6.47 FPS
ELEVATION = 497.30
MAGNITUDE = 1,620 CFS
VELOCITY = 8.64 FPS
ELEVATION = 501.11
DRAINAGE AREA = 7.83 SQ. MI.
BOT. R.S.F. EL. 482.00 � (TYP.)
4 EQUAL SPACES AT 5'-9 " = 23'-3"
ROLLED GIRDER SUPERSTRUCTURE
HERBERT, ROWLAND AND GRUBIC INC.
PREPARED BY
369 EAST PARK DRIVE
HARRISBURG, PA 17111
SUPPLEMENTAL DRAWINGS
DATE
BACKFILL AT STRUCTURES
DESCRIPTIONDESCRIPTION
GUIDE RAIL TO BRIDGE BARRIER TRANSITIONS
CLASSIFICATION OF EARTHWORK FOR STRUCTURES
REINFORCEMENT BAR FABRICATION DETAILS
ANCHOR SYSTEMS
BC-736M
BC-734M
RC-12M
RC-50M
DWG. NO.
BC-732MPERMANENT METAL DECK FORMS
12/18/24
06/01/10RC-11M
BC-752MCONCRETE SLAB DETAILS
BC-706M
11/01/22
INDEX OF DRAWINGS
TITLE
GENERAL NOTES
SLAB SECTION AND DETAILS3
SHEET NUMBER
GENERAL PLAN
TYPE 31 STRONG POST GUIDE RAIL RC-51M 12/18/24 RECOMMENDED
DISTRICT BRIDGE ENGINEER
46'-0" � BRG. TO � BRG.
25'-9 4"
OUT-TO-OUT
22'-8"
� TURTLE
CREEK ROAD
RAIL TO RAIL
FINISHED
SLOPE
STREAMBED
EL. �489.00
GRS WALL
CMU BLOCK
FACE (TYP.)
1.5
2 0 2 4 FEET
2 0 4 8 FEET
2 0 4 8 FEET
GUIDE RAIL
(ROADWAY ITEM)
(TYP.)
GUIDE RAIL
(ROADWAY ITEM)
(TYP.)
T U
R T
L E
C R
E E
K
SELECTED BORROW EXCAVATION ROCK,
CLASS R-8 CHOKED WITH R-4
(ROADWAY ITEM) (TYP.)
R A
I L
T O
R A
I L
WING D
WING A
WING C
� TURTLE CREEK ROAD
WING B
STA. AHEAD
O.F. BARRIER
O.F. BARRIER
(ROADWAY ITEM)
TO BE REMOVED
EXIST. STRUCTURE
� BRGS.
ABUT. 2
� BRGS.
ABUT. 1
NORMAL WATER
EL. � 492.00
PA 3-RAIL BRIDGE
BARRIER (TYP.)
8" MIN. CONCRETE
DECK
T
Y P
.)2
T
Y P
O U
T -T
O -O
U T
W12x210 (TYP.)
1'-6⅞" 1'-6⅞"
3.0% 3.0%
� BRGS. ABUT. 1
STA. 11+79.00
ELEV. 497.96
BEGIN STRUCTURE
STA. 11+77.00
ELEV. 497.97
� BRIDGE
STA. 12+02.00
ELEV. 497.85
� BRGS. ABUT. 2
STA. 12+25.00
ELEV. 497.73
END STRUCTURE
STA. 12+27.00
ELEV. 497.72
PROPOSED LOW CHORD EL. 495.49
EXISTING LOW CHORD EL. 496.12PROPOSED HIGH CHORD EL. 500.24
EXISTING LOW CHORD EL. 500.72
EXISTING WATERWAY OPENING: 139.43 SF
EXISTING LOW CHORD: EL. 496.12
EXISTING STREAMBED: EL. 489.00
EXISTING SPAN (CLEAR NORMAL): 19.58'
EXISTING HIGH CHORD: EL. 500.72
PROPOSED WATERWAY OPENING: 259.00 SF
PROPOSED LOW CHORD: EL. 495.49
PROPOSED STREAMBED: EL. 489.00
PROPOSED SPAN (CLEAR NORMAL): 38.67'
PROPOSED HIGH CHORD: EL. 500.24
ON TANGENT
-0.50% (STA. AHEAD)
25 YR. FLOOD
EL.497.30
100 YEAR FLOOD
EL. 501.11
DATUM: 480.00
SELECTED BORROW EXCAVATION
ROCK, CLASS R-8 CHOKED WITH
R-4 (ROADWAY ITEM) (TYP.)
11/23/22
02/19/21
11/23/22
10/07/24PA 3-RAIL BRIDGE BARRIER
11/23/22
ROCK, CLASS R-4
(ROADWAY ITEM) (TYP.)
GUIDE RAIL (TYP)
ENGINEER
PROFESSIONAL
REGISTERED
M
N
E P
N
S Y VL
A
A I
N
O
M
O C
T
EWN LA
O
H
F
TUCKER CORL
PE092836
08/11/2025
F I L
E N
A M
E
M
A R
:0
P
L O
T T
E D
P
\0
\O
R D
\B R
I D
G E
\b G
N .d g n
T
I M
E
U
S E
R
P L
O T
D R
I V
E R
P L
T D
R V
L
P
E N
T B
L S
P
E N
T A
B L
E
REVISIONS
Mark By Chk'd. DateDescription
REVISIONS
Mark By Chk'd. DateDescription
REVISIONS
Mark By Chk'd. DateDescription
DEPARTMENT OF TRANSPORTATION
COMMONWEALTH OF PENNSYLVANIA
SHEET OF
Recm'd.
BRIDGE REPLACEMENT
GENERAL NOTES
UNION COUNTY
OVER TURTLE CREEK
50'-0" SIMPLE SPAN ROLLED GIRDER BRIDGE
TURTLE CREEK ROAD STA. 12+02.00
EAST BUFFALO TOWNSHIP
RECOMMENDED
P2016-13 VEHICLES.
OPERATING RATINGS FOR THE H20, HS20, ML80, TK-527, AND P-82 OR
THE PRE-FABRICATED STEEL SUPERSTRUCTURE SHALL BE ANALYZED TO MEET THE
DESIGN IS IN ACCORDANCE WITH THE LRFD METHOD.
LIVE LOAD DISTRIBUTION IS BASED UPON DM-4 DISTRIBUTION FACTOR METHOD.
SUPPLEMENTED BY DESIGN MANUAL PART 4, DECEMBER 2019 EDITION.
AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS 8TH EDITION 2017, AND AS
DESIGN SPECIFICATIONS:
MANUFACTURER RECOMMENDATIONS AND SPECIFICATIONS.
ERECT AND INSTALL THE PRE-FABRICATED STEEL SUPERSTRUCTURE IN ACCORDANCE WITH
ALL FABRICATED STRUCTURAL STEEL TO BE 50 KSI.
DELIVERED TO THE SITE BY OTHERS.
ALL ITEMS FOR THE PRE-FABRICATED STEEL SUPERSTRUCTURE TO BE FABRICATED AND
DECK AND CURBS.
REINFORCING AND BE RESPONSIBLE FOR THE CONSTRUCTION OF THE CAST-IN-PLACE CONCRETE
STEEL SUPERSTRUCTURE MANUFACTURER. THE CONTRACTOR SHALL PROVIDE THE CONCRETE AND
ASSEMBLY HARDWARE, AND MOUNTING HARDWARE TO BE PROVIDED BY THE THE PRE-FABRICATED
RAIL ENDS, SPLICE TUBES, RAIL END CAPS, POSTS, POST PLATES, WOOD BLOCK OUTS,
PERMANENT METAL DECK FORMS, PENNDOT TYPE 3 BRIDGE RAILING CONSISTING OF RAILING,
WHO SEALED THE GRS ABUTMENT DRAWINGS PRIOR TO THE WORK BEING PERFORMED.
DETAILS AS SHOWN ON THESE DRAWINGS SHOULD FIRST BE APPROVED BY THE ENGINEER-OF-RECORD
BE CONSTRUCTED IN ACCORDANCE WITH THESE DRAWINGS. ANY DEVIATIONS FROM CONSTRUCTION
GRS ABUTMENT DRAWINGS ARE PROVIDED BY ETA, INC (5 SHEETS). THE GRS ABUTMENTS SHALL
ACCORDANCE WITH PUBLICATION 408/2020, SECTIONS 105.06 AND 107.12.
COORDINATE, LOCATE, AND CONDUCT ALL WORK RELATED TO PUBLIC AND PRIVATE UTILITIES IN
(814) 359-5250
BELLEFONTE, PA 16823
595 ROLLING RIDGE DRIVE
NORTHCENTRAL REGION
COOPERATE WITH FISH COMMISSION DURING CONSTRUCTION.
NOTIFY THE REGIONAL HEADQUARTERS OF THE FISH COMMISSION PRIOR TO CONSTRUCTION AND
DECK SLAB THICKNESS INCLUDES A 0.5" INTEGRAL WEARING SURFACE.
SUPERSTRUCTURE DIMENSIONS ARE SHOWN FOR A NORMAL TEMPERATURE OF 68 DEGREES F.
ALL DIMENSIONS SHOWN ARE HORIZONTAL, EXCEPT AS NOTED.
CHAMFER EXPOSED CONCRETE EDGES 3/4 IN BY 3/4 IN, EXCEPT AS NOTED.
USE EPOXY-COATED REINFORCEMENT BARS IN ALL COMPONENTS UNLESS OTHERWISE NOTED.
USE RETARDER ADMIXTURE CONFORMING TO PUBLICATION 408/2020 IN THE CONCRETE DECK SLAB.
USE REMOVABLE FORMS TO CONSTRUCT BEAM SEAT.
PREPARE BEARING AREAS AS SPECIFIED IN PUBLICATION 408, SECTION 1001.3.(K)9.
RAKE-FINISH ALL HORIZONTAL CONSTRUCTION JOINTS, EXCEPT AS INDICATED.
SPECIFIED.
WELDING OF REINFORCEMENT STEEL DURING FABRICATION OR CONSTRUCTION IS NOT PERMITTED UNLESS
SPECIFIED.
WELDING OF REINFORCEMENT BARS DURING FABRICATION OR CONSTRUCTION IS NOT PERMITTED UNLESS
AREA, IF APPROVED BY THE ENGINEER. DO NOT USE RAIL STEEL A 996 REINFORCEMENT BARS.
REINFORCING STEEL BARS MAY BE SUBSTITUTED WITH A PROPORTIONAL INCREASE IN CROSS-SECTIONAL
OR A 706. DO NOT WELD GRADE 60 REINFORCING STEEL BARS UNLESS SPECIFIED. GRADE 40
PROVIDE GRADE 60 REINFORCING STEEL BARS THAT MEET THE REQUIREMENTS OF ASTM A 615, A 996, COST TO THE OWNER IF APPROVED BY THE ENGINEER.
A HIGHER CLASS CONCRETE MAY BE SUBSTITUTED FOR A LOWER CLASS CONCRETE AT NO ADDITIONAL
USE CLASS AA CEMENT CONCRETE IN: CURBS/BARRIERS.
USE CLASS AAAP CEMENT CONCRETE IN: DECK SLAB.
PROVIDE 2" CONCRETE COVER ON REINFORCEMENT BARS, EXCEPT AS NOTED.
STATIONS AND ELEVATIONS ARE GIVEN IN FEET UNLESS OTHERWISE NOTED.
ENGINEER PRIOR TO THE WORK BEING PERFORMED.
FROM CONSTRUCTION DETAILS AS SHOWN ON THESE PLANS SHOULD FIRST BE APPROVED BY THE
PRE-FABRICATED STEEL SUPERSTRUCTURE BY TOWNSHIP MAINTENANCE FORCES. ANY DEVIATIONS
THESE PLAN SHEETS WERE PREPARED TO ASSIST IN THE CONSTRUCTION OF GRS ABUTMENTS AND
AASHTO/AWS D1.5M/D1.5 2020 BRIDGE WELDING CODE, AND CONTRACT SPECIAL PROVISIONS.
PROVIDE MATERIALS AND PERFORM WORK IN ACCORDANCE WITH SPECIFICATIONS, PUBLICATION 408/2020, GENERAL NOTES
.0
L
.1
L
.2
L
.3
L
.4
L
.5
L
.6
L
.7
L
.8
L
.9
L
.0
L GUTTER LINE
LEFT
BRIDGE
BEGIN
ABUT. 1
� BRG.
GUTTER LINE
RIGHT
ABUT. 2
� BRG.
BRIDGE
END
TOP OF DECK ELEVATIONS
LOCATION LT. GUTTER P.G. RT. GUTTER
END BRIDGE
1.0L
0.9L
0.8L
0.7L
0.6L
0.5L
0.4L
0.3L
0.2L
0.1L
0.0L
BEGIN BRIDGE
497.38
497.39
497.41
497.43
497.46
497.48
497.50
497.53
497.55
497.57
497.59
497.62
497.63
497.72
497.73
497.75
497.78
497.80
497.82
497.85
497.87
497.89
497.91
497.94
497.96
497.97
497.38
497.39
4967.41
497.43
497.46
497.48
497.50
497.53
497.55
497.57
497.59
497.62
497.63
CONSTRUCTION SPECIFICATIONS
GENERAL
UTILITIES
GRS ABUTMENTS
PRE-FABRICATED STEEL SUPERSTRUCTURE
DES: DWG:TJC JPD CKD: TJC
ENGINEER
PROFESSIONAL
REGISTERED
M
N
E P
N
S Y VL
A
A I
N
O
M
O C
T
EWN LA
O
H
F
TUCKER CORL
SLAB SECTION
#6
½
2'-6"
11" 8" 8" 3"
SECTION C-C
A
A
8" ⅝
7"
4" 4"
1¾" (TYP)
� POST � POST � POST
8" ⅝
4"
1¾" (TYP)
� POST
4"
TYPICAL BARRIER ELEVATION
½
2'-6"
11"8"8"3"
SECTION B-B
CCB B
SECTION A-A
2'-1"
8½"
12 0 12 INCHES
6 0 6 12 INCHES6 0 6 12 INCHES
6 0 6 INCHES
F
IL
E N
A M
E
-A
U G
-2
:4
P
L O
T T
E D
P
\0
\O
R D
\B R
ID
G
E \b
D
E T
.d g n
T
IM
E
U
S E
R
P L O
T D
R
IV
E R
P
L T
D R
V L
P
E N
T B
L S
P
E N
T A
B L E
REVISIONS
Mark By Chk'd. DateDescription
REVISIONS
Mark By Chk'd. DateDescription
REVISIONS
Mark By Chk'd. DateDescription
DEPARTMENT OF TRANSPORTATION
COMMONWEALTH OF PENNSYLVANIA
SHEET OF
Recm'd.
BRIDGE REPLACEMENT
SLAB SECTION AND DETAILS
UNION COUNTY
OVER TURTLE CREEK
50'-0" SIMPLE SPAN ROLLED GIRDER BRIDGE
TURTLE CREEK ROAD STA. 12+02.00
EAST BUFFALO TOWNSHIP
DES: CKD:TJC DWG: JPD TJC
RECOMMENDED
7"
4"4"
� TURTLE
CREEK ROAD
PA 3-RAIL BRIDGE
BARRIER (TYP.)
(TYP.)
W12x210
3.0% 3.0%
1 0 1 2 FEET
8"
W6X20
1'-6⅞"
1'-6"
¾"X¾" CHAMFER
(TYP)
HSS 4"x3"
RAIL TUBE
(TYP)
⅝" DIA ROUND HEAD
BOLT WITH HEX NUT
⅞" ASTM A449 OR F1554, GRADE 105,
GALV ANCHOR BOLTS W/ LEVELING NUTS,
PLAIN WASHERS AND HEX NUTS
1" BASE �
CURB
6"x6"x1'-10"
WOOD BLOCK
1'-6"
2" CLR
1'- 4½ "
1'-4"
GUTTER LINE
4"
C U
R B
3" 2 SPA
@ 9"
2 SPA
@ 9"
2'-6"
2 SPA
@ 9"
2 SPA
@ 9"
2'-6"8 SPA. @ 5'-7½" = 45'-0"
(POST SPACING)
GUTTER LINE
1'-6"
TOP OF
RAIL
REINFORCED CONCRETE
DECK SLAB
REINFORCED
CONCRETE
CURB
2 EQ. SPA.
2 SPA @ 8"
=1'-4"
2 EQ. SPA.
#4
1'-6"
2" CLR
1'-4½ "
1'-4"
GUTTER LINE
#4
� POST
#6
#4 (TYP.)
50'-0"
4"
C U
R B
#6
2" CLR.
(TYP.)
2" C L R
#5 @ 5½" (BUNDLE WITH
TOP TRANSVERSE BARS)
(TYP.)
#5 @ 5½"
#5 @ 7"
½
C
L R
C
L R
#5 @ 5½" (BUNDLE WITH
TOP TRANSVERSE BARS)
(TYP.)
#4 (SEE TYPICAL BARRIER
ELEVATION FOR SPACING)
EPOXY COAT ALL REINFORCEMENT.
#5 @ 10" (EACH BAY)
3" (TYP.)
3"
1'-6"
2 SPA @ 8"
=1'-4"
#6 #6
(EACH BAY)
#4 @ 12" MAX.
NOTE:
2'-6"
T Y
P
⅜
T
Y P
1'-6⅞" 1'-6⅞"
" = 23'-3"¾4 EQ. SPA. @ 5'-9
ROLLED GIRDER SUPERSTRUCTURE
25'-9¾"
OUT-TO-OUT
22'-8"
RAIL TO RAIL
⅜
� POST
EQ. SPA.
3-#5 @
EQ. SPA.
3-#4 @
EQ. SPA.
3-#5 @
EQ. SPA.
3-#4 @
CONCRETE DECK
8" MIN.
(TYP.)
1'-0"
#3 @ 14"*
2-#4*
*PROVIDE HAUNCH REINFORCEMENT WHEN HAUNCH THICKNESS IS 3" OR GREATER
1" CLR.
ENGINEER
PROFESSIONAL
REGISTERED
M
N
E P
N
S Y VL
A
A I
N
O
M
O C
T
EWN LA
O
H
F
TUCKER CORL
| b00029240452GN |
| b00029240452DET |