659-20-200 Police Radio 100p CD Drawing Set.pdf
PDF 8 MB Posted
- Attached to
- Z1DA--Police Radios Upgrade
- Solicitation number
- 36C24623B0015
About this file
This is a federal solicitation for a police radio upgrade project at a Department of Veterans Affairs facility. The scope of work involves installing a fiber distributed antenna system to provide radio coverage for VA police radios in buildings on the site. The system must support 75 Motorola APX6000 and 2 Motorola APX4500 series radios with FIPS 140-2 encryption. It must integrate with existing infrastructure and allow new radio firmware, code plugs, and other items. All radios will be programmed with approved VA and North Carolina public safety frequencies. Construction will follow VA specifications, infection control guidelines, and applicable codes while minimizing space disruptions.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Copy of Copy of 36C24623B0015-Salisbury_VAMC_questions_v2.xlsx | XLSX spreadsheet | |
| 36C24623B0015 0002.docx | DOCX document | |
| Lucayan Questions - Solicitation _ 36C24623B0015_.docx | DOCX document | |
| 659-20-200_SiteVisit-SignIn_20230125.pdf | ||
| 36C24623B0015 0001.docx | DOCX document | |
| 36C24623B0015_1.docx | DOCX document | |
| 659-20-200 Police Radio 100p Specifications.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
J
H N
F RAIN
E
P R
O F
ES S ION A L ENG
I N
E E
R
L I CENSE
F
LO R I D A
STATE OF
No. 90063
O
REDERICK
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120
FULLY SPRINKLERED
Department of Veterans Affairs Medical Center
ABOVE GROUP, INC.
MECHANICAL ELECTRICAL PLUMBING
305 EAST DRIVE, SUITE H
MELBOURNE, FL 32904
321.345.9026 P
305 East Dr., Suite H, Melbourne, Florida 32904
PH: 321.345.9026
B
IM
/0
P o lic e
R a d io s U p g ra d e
S a lis b u ry /0
P o lic e R a d io s U p g ra d e R
D iv
.r v t
/2 /2
:3
:1
P
M
GI001
COVER SHEET POLICE RADIOS UPGRADE
SALISBURY, NC
659-20-200
12/21/21 JFR BMS
100% CONSTRUCTION
DOCUMENTS
POLICE RADIOS UPGRADE
W.G. Hefner VAHCS 1601 Brenner Ave, Salisbury, NC 28144 PROJECT #: 659-20-200
100% CONSTRUCTION DOCUMENTS
STANTON ENGINEERING SERVICES
LIFE SAFETY
10280 OLD COLUMBIA RD, SUITE 275
COLUMBIA, MD 21046
410.290.9301 P
PROJECT LOCATION
NTS
Revisions Date
1PH SINGLE-PHASE
3PH THREE-PHASE
4W FOUR-WIRE
A/E ARCHITECT/ENGINEER
AF AMPERE FRAME OR AMP FUSE
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AHJ AUTHORITY HAVING JURISDICTION
AIC AMPERE INTERRUPTING CAPACITY
ALT ALTERNATE
AMP AMPERE
ASC AMPS SHORT CIRCUIT
AT AMPERE TRIP
ATS AUTOMATIC TRANSFER SWITCH
AUTO AUTOMATIC
AV AUDIO VISUAL
BLDG BUILDING
C CONDUIT
CAT CATALOG
CATV COMMUNITY ANTENNA TELEVISION
CCTV CLOSED CIRCUIT TELEVISION
cd CANDELA
CD CONSTRUCTION DOCUMENTS
CKT CIRCUIT
CLG CEILING
COAX COAX CABLE
COMM COMMUNICATION
CONC CONCRETE
CONT CONTINUE
COORD COORDINATE
CRI COLOR RENDERING INDEX
CT CURRENT TRANSFORMER
CU COPPER
DB DECIBEL OR DIRECT BURIAL
DC DIRECT CURRENT
DEG C DEGREES CELSIUS
DEG F DEGREES FAHRENHEIT
DEMO DEMOLITION
DISC DISCONNECT
DN DOWN
DPDT DOUBLE POLE, DOUBLE THROW
DPST DOUBLE POLE, SINGLE THROW
DS DISCONNECT SWITCH
DWG DRAWING
ELEC ELECTRIC OR ELECTRICAL
ELEV ELEVATOR
EMT ELECTRICAL METALLIC TUBING
ENCL ENCLOSURE
EPO EMERGENCY POWER OFF
ESMT EASEMENT
EWC ELECTRIC WATER COOLER
EWH ELECTRIC WATER HEATER
ETR EXISTING TO REMAIN
ELECTRICAL ABBREVIATIONS
FA FIRE ALARM
FAAP FIRE ALARM ANNUNCIATOR PANEL
FACP FIRE ALARM CONTROL PANEL
FC FOOTCANDLE
FLA FULL LOAD AMPS
FP FIRE PROTECTION
FT FEET OR FOOT
GND GROUND
G or GFCI GROUND FAULT CIRCUIT INTERRUPTER
GTB GROUND TERMINAL BOX
HOA HAND-OFF-AUTOMATIC
HP HORSEPOWER
HZ HERTZ
IESNA ILLUMINATION ENGINEERING SOCIETY OF NORTH AMERICA
IMC INTERMEDIATE METAL CONDUIT
IR INFRARED
IWH INSTANTANEOUS WATER HEATER
J-BOX JUNCTION BOX
kV KILOVOLT kVA KILOVOLT AMPERE kVAH KILOVOLT AMPERE PER HOUR kVAR KILOVOLT AMPERE REACTIVE kW KILOWATT kWH KILOWATT HOUR
LED LIGHT EMITTING DIODE
LF LINEAR FEET (FOOT)
LM LUMEN
LP LIGHT POLE
LRA LOCKED ROTOR AMPS
LTG LIGHTING
LV LOW VOLTAGE
MAX MAXIMUM
MC METAL-CLAD
MCA MINIMUM CIRCUIT AMPS
MCB MAIN CIRCUIT BREAKER
MCC MOTOR CONTROL CENTER
MDP MAIN DISTRIBUTION PANEL
MECH MECHANICAL
MH MANHOLE
MIN MINIMUM
MOCP MAXIMUM OVERCURRENT PROTECTION
MLO MAIN LUGS ONLY
MTD MOUNTED
MTG MOUNTING
MTS MANUAL TRANSFER SWITCH
MV MEDIUM VOLTAGE
MVA MEGAVOLT-AMPERE
MW MEGAWATT MICROWAVE
NC NORMALLY CLOSED
NEC NATIONAL ELECTRICAL CODE
NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION
NEUT OR N NEUTRAL
NFPA NATIONAL FIRE PROTECTION ASSOCIATION
NIC NOT IN CONTRACT
NL NIGHT LIGHT
NO NORMALLY OPEN
NS NO SCALE
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
OL OVERLOAD
P POLE
PA PUBLIC ADDRESS
PCB POLYCHLORINATED BIPHENYL
PH PHASE
PNL PANEL
POD POWER OPERATED DAMPER
PVC POLYVINYL CHLORIDE (PLASTIC)
PWR POWER
RCP REFLECTED CEILING PLAN
RGS RIGID GALVANIZED STEEL
RM ROOM
RMS ROOT MEAN SQUARE
REQD REQUIRED
SCC SHORT CIRCUIT CAPACITY
SD SMOKE DETECTOR
SF SQUARE FOOT (FEET)
SI INTERNATIONAL SYSTEM OF UNITS
SPEC SPECIFICATION
SPST SINGLE POLE, SINGLE THROW
SW SWITCH
SWBD SWITCHBOARD
SWGR SWITCHGEAR
TEL TELEPHONE
TP TWISTED PAIR
TPS TWISTED PAIR SHIELDED
TTB TELEPHONE TERMINAL BOARD
TV TELEVISION
TYP TYPICAL
UGND UNDERGROUND
UL UNDERWRITERS LABORATORY
UON UNLESS OTHERWISE NOTED
UPS UNINTERRUPTIBLE POWER SUPPLY
V VOLT
VA VOLT AMPERE
VAR VOLT AMPERE REACTIVE
VFD VARIABLE FREQUENCY DRIVE
VOLT VOLTAGE
W WATT
WH WATER HEATER
WP WEATHERPROOF
XFER TRANSFER
XFMR TRANSFORMER
ABBR. DESCRIPTION ABBR. DESCRIPTION ABBR. DESCRIPTION
AWG AMERICAN WIRE GAUGE
KCMIL ONE-THOUSAND CIRCULAR MILS
NA NOT APPLICABLE
HD HEAT DETECTOR
NEW (HEAVY, SOLID LINE)
EXISTING TO REMAIN (LIGHT, SOLID LINE)
EXISTING TO BE REMOVED (HEAVY, DASHED LINE)
ELECTRICAL SYMBOLS - POWER/LIGHTING PLANS
SYMBOL DESCRIPTION
ALARM, FIRE, PANEL; LETTERS INDICATE AS FOLLOWS:
NAC = BOOSTER PANEL FACP = CONTROL PANEL
FAAP = ANNUNCIATOR PANEL
FACP
BRANCH CIRCUIT HOMERUN. "ABCD" INDICATES PANEL NAME, "##" INDICATE POLE POSITIONS IN PANEL. ONE
SEPARATE GREEN GROUNDING CONDUCTOR SHALL BE PROVIDED FOR EACH HOMERUN
ABCD-##
BRANCH CIRCUIT PANELBOARD, OVER 250 VOLTS, SURFACE MOUNTED
BRANCH CIRCUIT PANELBOARD, OVER 250 VOLTS, FLUSH MOUNTED
BRANCH CIRCUIT PANELBOARD, UNDER 250 VOLTS, SURFACE MOUNTED
BRANCH CIRCUIT PANELBOARD, UNDER 250 VOLTS, FLUSH MOUNTED
SWITCHBOARD/ SWITCHGEAR/ DISTRIBUTION PANEL, UNDER 250 VOLTS
SWITCHBOARD/ SWITCHGEAR/ DISTRIBUTION PANEL - OVER 250 VOLTS
DN
UP
CONDUIT CONTINUED
CONDUIT STUBBED OUT OR UP
CONDUIT TURNING DOWN
CONDUIT TURNING UP
BDA BI-DIRECTIONAL AMPLIFIER
DAS DISTRIBUTED ANTENNA SYSTEM RF-EMITTING ANTENNA
PUBLIC SAFETY RADIO DONOR ANTENNA - MOUNTED ON ROOF, COORDINATE EXACT LOCATION WITH COR, SEE PUBLIC
SAFETY RADIO ENHANCEMENT SYSTEM RISER DIAGRAMS FOR FURTHER DETAILS.
COR CONTRACTING OFFICER'S REPRESENTATIVE
COTR CONTRACTING OFFICER'S TECHNICAL REPRESENTATIVE
T RF TAPPER - SEE PUBLIC SAFETY RADIO ENHANCEMENT SYSTEM RISER DIAGRAMS FOR FURTHER DETAILS.
5. ALL BRANCH CIRCUIT HOMERUNS SHALL BE ROUTED IN 3/4"C. MINIMUM.
6. EQUIPMENT SHALL BE OF MATERIALS SUITABLE FOR AND RATED FOR THE ENVIRONMENT IN WHICH THEY ARE TO BE INSTALLED, WITH APPROPRIATE NEMA
ENCLOSURE RATING.
GENERAL NOTES
1. ALL WORK SHALL BE IN ACCORDANCE WITH THE LATEST ADOPTED EDITION OF THE NATIONAL ELECTRICAL CODE (NEC), NFPA, ADA, ALL LOCAL AND STATE
BUILDING CODES, SAFETY CODE, ORDINANCES AND REGULATIONS.
2. REFER TO THE SPECIFICATIONS FOR INFORMATION NOT SHOWN ON THE DRAWINGS.
3. EACH BRANCH CIRCUIT RACEWAY SHALL HAVE A FULL LENGTH EQUIPMENT GROUND CONDUCTOR.
4. PROVIDE 18" LONG (MIN). CONDUIT SLEEVES THRU ALL WALLS WHERE CABLES ARE INDICATED OR REQUIRED TO PASS THRU WALLS. PROVIDE BUSHINGS ON
BOTH ENDS. SIZE CONDUIT FOR CABLES INSTALLED.
a. WORKING CLEARANCES FOR ELECTRICAL EQUIPMENT SHALL BE IN COMPLIANCE WITH NEC 110.26.
b. THE EXCLUSIVELY-DEDICATED ELECTRICAL SPACE EXTENDING FROM FLOOR TO A HEIGHT OF 6'-6" AFF OR TO THE HEIGHT OF EQUIPMENT AND A WIDTH
OF 30" OR WIDTH OF THE EQUIPMENT, WHICH EVER DIMENSIONS ARE GREATER, MUST BE CLEAR OF ALL PIPING, DUCTS OR EQUIPMENT FOREIGN TO THE ELECTRICAL EQUIPMENT OR ARCHITECTURAL APPURTENANCES IN ACCORDANCE WITH NEC 110.26A(2)&(3).
7. ALL BRANCH CIRCUIT CONDUITS SHALL CONTAIN A MINIMUM OF (2) #12AWG WIRES, PLUS A MINIMUM OF #12AWG GROUND WIRE UNLESS OTHERWISE NOTED.
ALL BRANCH CIRCUITS AS SHOWN ON THE DRAWINGS SHALL BE INSTALLED AS INDICATED UNLESS PRIOR APPROVAL FROM THE ENGINEER AND OWNER IS RECEIVED IN WRITING. ALL BRANCH AND FEEDERS CIRCUITS SHALL HAVE INDIVIDUAL NEUTRAL CONDUCTORS, MINIMUM CONDUIT SIZE SHALL BE 3/4".
8. CONTRACTOR SHALL UPSIZE BRANCH CIRCUIT WIRE SIZE AS REQUIRED TO COMPENSATE FOR VOLTAGE DROP FROM LENGTHENING OF CIRCUITS DUE TO FIELD ROUTING. IN SUCH CASES, THE EQUIPMENT GROUNDING CONDUCTOR SIZE SHALL BE INCREASED PROPORTIONATELY TO INCREASE IN SIZE OF THE
UNGROUNDED CONDUCTORS, PER NEC 250.122(B). .
9. ALL LINE VOLTAGE WIRING SHALL BE IN CONDUIT AND INCLUDE SEPARATE GROUNDING CONDUCTOR.
10. BI-DIRECTIONAL AMPLIFIER (BDA) SYSTEM SHALL COMPLY WITH NFPA 70, 72 AND 1221 FOR INSTALLATION PRACTICES.
11. STATE CERTIFIED AND LICENSED BI-DIRECTIONAL AMPLIFIER (BDA) SYSTEM CONTRACTOR SHALL SUBMIT ENGINEERED SIGNED AND SEALED SHOP DRAWINGS
TO AUTHORITY HAVING JURISDICTION COMPLYING WITH STATE AND LOCAL CODES/STANDARDS.
12. BI-DIRECTIONAL AMPLIFIER (BDA) SYSTEM AND DISTRIBUTED ANTENNA SYSTEM (DAS) CABLING SHALL NOT HAVE SPLICES.
13. DISTRIBUTED ANTENNA SYSTEM (DAS) DESIGN IS PROVIDED FOR INFORMATIONAL PURPOSES TO ASSIST THE AUTHORITY HAVING JURISDICTION DURING THE
REVIEW PROCESS, AND TO ASSIST CONTRACTOR(S) DURING THE PROPOSAL CYCLE.
14. PER NFPA 1221 SECTION 9.6.11.2.1, ALL REPEATER, TRANSMITTER, RECEIVER, SIGNAL BOOSTER COMPONENTS, OPTICAL-TO-RF AND RF-TO-OPTICAL
CONVERTERS, EXTERNAL FILTERS, BATTERIES, AND BATTERY SYSTEM COMPONENTS SHALL BE CONTAINED IN A NEMA 4 OR NEMA 4X ENCLOSURE.
15. PER NFPA 1221 SECTION 9.6.7.5, RF-EMITTING DEVICES SHALL BE CERTIFIED BY THE RADIO LICENSING AUTHORITY.
16. PER NFPA 1221 SECTION 9.6.8, INBOUND AND OUTBOUND SIGNAL LEVEL SHALL BE SUFFICIENT TO PROVIDE A MINIMUM DAQ 3.0 FOR EITHER DIGITAL OR ANALOG
SIGNALS.
APPLICABLE CODES
ALL FURNISHED ELECTRIC EQUIPMENT, MATERIALS, AND INSTALLATION SHALL BE IN ACCORDANCE WITH THE LATEST ADOPTED EDITION BY THE AUTHORITIES HAVING JURISDICTION, OF THE CODES AND STANDARDS OF THE FOLLOWING
ORGANIZATIONS:
1. NATIONAL FIRE PROTECTION ASSOCIATION (NFPA), INCLUDING (BUT NOT LIMITED TO):
a. NATIONAL ELECTRICAL CODE (NEC), NFPA 70
b. NATIONAL FIRE ALARM CODE, NFPA 72
c. LIFE SAFETY CODE, NFPA 101
d. EMERGENCY AND STANDBY POWER SYSTEMS, NFPA 110
e. EMERGENCY SERVICES COMMUNICATIONS SYSTEM, NFPA 1221
f. LIGHTNING PROTECTION, NFPA 780
2. AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI), INCLUDING (BUT NOT LIMITED TO):
a. NATIONAL ELECTRICAL SAFETY CODE, ANSI C2
3. OCCUPATIONAL SAFETY AND HEALTH ACT (OSHA)
4. FEDERAL COMMUNICATION COMMISSION (FCC)
5. NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION (NEMA)
6. INSULATED CABLE ENGINEERS ASSOCIATION (ICEA)
7. INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS (IEEE)
8. NATIONAL ELECTRICAL TESTING ASSOCIATION (NETA)
9. AMERICAN SOCIETY OF TESTING AND MATERIALS (ASTM)
10. ANTI-FRICTION BEARING MANUFACTURERS ASSOCIATION (AFBMA)
11. BUILDING OFFICIALS AND CODE ADMINISTRATORS INTERNATIONAL, INC. (BOCA)
12. UNIFORM BUILDING CODE (UBC)
13. COMBINED ANSI/ASHRAE/IES STANDARD 90.1 – “ENERGY STANDARD FOR BUILDINGS EXCEPT LOW-RISE RESIDENTIAL
BUILDINGS”
14. NATIONAL ELECTRICAL CONTRACTORS ASSOCIATION INSTALLATION STANDARDS (NECA)
15. AMERICANS WITH DISABILITIES ACT (ADA)
16. APPLICABLE STATE AND LOCAL CODES, AMENDMENTS, REGULATIONS, AND PRACTICES.
17. APPLICABLE REGULATORY REQUIREMENTS AND ADVISORY PRACTICES OF APPROPRIATE AUTHORITIES HAVING JURISDICTION
(AHJs).
18. APPLICABLE STANDARDS, REGULATIONS, AND PRACTICES OF THE OWNER.
WHERE A CONFLICT EXISTS BETWEEN THE AUTHORITY HAVING JURISDICTION, APPLICABLE STATE AND LOCAL BUILDING CODES, AMENDMENTS, REGULATIONS, AND PRACTICES, AND ANY PROVISIONS OF THE ABOVE REFERENCED CODES OR STANDARDS, THE
MORE STRINGENT OR RESTRICTIVE REQUIREMENT SHALL TAKE PRECEDENCE.
DEDUCT ALTERNATES
AS PART OF THE BID PACKAGE, PROVIDE DEDUCT
ALTERNATE PRICES FOR THE FOLLOWING BUILDINGS:
ALTERNATE BUILDING REFERENCED SHEET
1 13 EP120
2 14E EP119
3 14W EP119
4 15 EP120
5 16 EP120
6 17 EP121
7 18 EP121
J
H N
F RAIN
E
P R
O F
ES S ION A L ENG
I N
E E
R
L I CENSE
F
LO R I D A
STATE OF
No. 90063
O
REDERICK
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120
FULLY SPRINKLERED305 East Dr., Suite H, Melbourne, Florida 32904
PH: 321.345.9026
B
IM
/0
P o lic e
R a d io s U p g ra d e
S a lis b u ry /0
P o lic e R a d io s U p g ra d e R
D iv
.r v t
/2 /2
:3
:1
P
M
E-001
ELECTRICAL GENERAL NOTES,
LEGENDS & SYMBOLS
POLICE RADIOS UPGRADE
SALISBURY, NC
659-20-200
12/21/21 BMS SDL
100% CONSTRUCTION
DOCUMENTS
SHEET LIST
Sheet Number Sheet Name
E-001 ELECTRICAL GENERAL NOTES, LEGENDS & SYMBOLS
E-002 CAMPUS MAP
EP101 BUILDING 1 FLOOR PLANS - POWER
EP102 BUILDING 2 GROUND FLOOR PLAN - POWER
EP103 BUILDING 2 FIRST FLOOR PLAN - POWER
EP104 BUILDING 2 SECOND FLOOR PLAN - POWER
EP105 BUILDING 2 THIRD FLOOR PLAN - POWER
EP106 BUILDING 2 FOURTH FLOOR PLAN - POWER
EP107 BUILDING 2 FIFTH FLOOR PLAN - POWER
EP108 BUILDING 3 GROUND, FIRST AND SECOND FLOOR PLANS - POWER
EP109 BUILDING 3 THIRD AND FOURTH FLOOR PLANS - POWER
EP110 BUILDING 4 GROUND FLOOR PLAN - POWER
EP111 BUILDING 4 FIRST AND SECOND FLOOR PLANS - POWER
EP112 BUILDING 4 THIRD AND FOURTH FLOOR PLAN - POWER
EP113 BUILDING 5 GROUND AND FIRST FLOOR PLANS - POWER
EP114 BUILDING 6 GROUND FLOOR PLAN - POWER
EP115 BUILDING 6 FIRST FLOOR PLAN - POWER
EP116 BUILDING 7 FLOOR PLANS - POWER
EP117 BUILDING 8 FLOOR PLANS - POWER
EP118 BUILDING 11 FLOOR PLANS - POWER
EP119 BUILDING 12, 14E, AND 14W PLANS - POWER
EP120 BUILDING 13, 15, AND 16 PLANS - POWER
EP121 BUILDING 17, 18, AND 19 PLANS - POWER
EP122 BUILDING 20 FLOOR PLANS - POWER
EP123 BUILDING 21 GROUND AND FIRST FLOOR PLANS - POWER
EP124 BUILDING 21 SECOND FLOOR AND 31 PLANS - POWER
EP125 BUILDING 42 GROUND FLOOR PLAN - POWER
EP126 BUILDING 42 FIRST FLOOR PLAN - POWER
EP127 BUILDING 42 SECOND FLOOR PLAN - POWER
EP128 BUILDING 43 FIRST FLOOR PLAN - POWER
E-501 ELECTRICAL DETAILS
E-801 ELECTRICAL SCHEDULES
E-802 ELECTRICAL SCHEDULES
E-803 ELECTRICAL SCHEDULES
E-804 ELECTRICAL SCHEDULES
N O
R T H
MASTER BDA INSTALLED IN THIS BUILDING
REMOTE BDA INSTALLED IN THIS BUILDING
BUILDING LEGEND
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
11A.
11B.
11C.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
21A.
21B.
22.
24.
25.
28.
29.
30.
31.
32.
33.
34.
35.
36.
37.
38.
39.
40.
41.
42.
43.
44.
ADMINISTRATION BUILDING
G. M. & S BUILDING
OUTPATIENT CLINICS
MENTAL HEALTH OFFICES
MAIN KITCHEN
RECREATION BUILDING
R.M.S & CORE CLINIC BUILDING
PATIENT TREATMENT (MENTAL HEALTH)
PARKING GARAGE
N.C. VETERANS HOME
MENTAL HEALTH OFFICES
MENTAL HEALTH OFFICES
MENTAL HEALTH OFFICES
CALL CENTER
POLICE HEADQUARTERS
STUDENT LODGING
E&W CWT HOMELESS AND POLICE
ADMIN
LAUNDRY
WAREHOUSE
BOILER PLANT
CHAPEL
CLINIC LAB
LOGISTICS, IRM, ENDOSCOPE, PODIATRY,
ONCOLOGY, SLEEP CLINIC
FEE BASIS
ENGINEERING
FLAG POLE
R.M.&S STORAGE
R.M.&S STORAGE
ENGINEERING PAINT SHOP
R.M.&S. STORAGE
GREENHOUSE
CHILLER PLANT
GENERATOR BUILDING
SWITCHGEAR BUILDING
GENERATOR BUILDING
GENERATOR BUILDING
GENERATOR BUILDING
GENERATOR BUILDING
GENERATOR BUILDING
PICNIC SHELTER
GROUNDS STORAGE SHELTER
NCA SHELTER
GEROPSYCHIATRIC BUILDING
HOSPICE BUILDING
GATES
J
H N
F RAIN
E
P R
O F
ES S ION A L ENG
I N
E E
R
L I CENSE
F
LO R I D A
STATE OF
No. 90063
O
REDERICK
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120
FULLY SPRINKLERED305 East Dr., Suite H, Melbourne, Florida 32904
PH: 321.345.9026
B
IM
/0
P o lic e
R a d io s U p g ra d e
S a lis b u ry /0
P o lic e R a d io s U p g ra d e R
D iv
.r v t
/2 /2
:3
:1
P
M
E-002
CAMPUS MAP POLICE RADIOS UPGRADE
SALISBURY, NC
659-20-200
12/21/21 BMS SDL
100% CONSTRUCTION
DOCUMENTS
N.T.S.E-002
1 CAMPUS MAP
135F
OFFICE
135C
OFFICE
135C
OFFICE
135B
OFFICE
OFFICE
STAIRS#3
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
CORRIDOR
TOILET
CLOSET
TOILET
LOBBY
120A
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
108D
OFFICE
OFFICE
104A
OFFICE
108C
OFFICE
104B
OFFICE
300 108B
OFFICE
OFFICE
104C
OFFICE
MAILROOM
LOBBY
STAIRS#2
101A
KEYPUNCH
M. BOXES
103A
STORAGE
CORRIDOR
OFFICE
108A
OFFICE
TOILET
F. TOILET
OFFICE
STAIR#1
MOP
OFFICE
CORR.
102A
OFFICE
M. TLT
STORAGE
ELEVATOR
FEC
F. TOILET
M. TOILET
DASDASDASDASDAS
DAS
DAS
DAS
DAS
DAS
G01
MECH RM
G03
MECH RM
G04
MECH RM
G02
MECH RM
G05
MECH RM
G08
OFFICE
G06
OFFICE
G09
VENDING RM.
G06C
CORR.
G07
STAIR
G10
FILE STORAGE
FEC
DAS
DAS
DN
DN
DN
UP
DN
DN
DIRECTOR'S OFFICE
222A
Assoc Dir Office
OFFICE
OFFICE
STOR.
CONF. RM.
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
STOR.
OFFICE
OFFICE
OFFICE
STORAGE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
STAIR#2
OFFICE
STAIR#3
LOUNGE
CORRIDOR
CORR.
STAIR#1
TOILET
TOILET
M. TOILET
LOUNGE
MOP
TOILET
CLOSET
TOILET
CLOSET
234A
TOILET
TOILET
HAC
DASDASDASDASDAS
DAS
DAS
DAS
DAS
EXISTING FIRE ALARM
CONTROL PANEL FACP-01
EXISTING FIRE ALARM
ANNUNCIATOR PANEL FAAP
EXISTING PANEL MAIL
MAIL-8
MAIL-6
MOUNTED ON ROOF ABOVE
24V
BATTERY
MASTER
BDA
AMPLIFIER
BDA
ANNUNCIATOR
CONNECT TO FIRE ALARM PANEL FACP-01
(8) SUPERVISORY INPUT MODULES REQUIRED:
• BDA ANTENNA FAILURE
• BDA TROUBLE
• BDA POWER LOSS
• BDA CHARGER TROUBLE
• BDA LOW BATTERY
• ANNUNCIATOR TROUBLE
• PRIMARY/SECONDARY POWER SOURCE INTEGRITY (NFPA 1221 9.1.2.2)
PROVIDE REQUIRED PROGRAMMING TO THE BUILDING FIRE ALARM CONTROL
PANEL. PROVIDE TESTING OF EACH FAULT CONDITION AS PART OF SYSTEM
ACCEPTANCE TESTING.
MAIL-6 / MAIL-8
(20A EMERGENCY CIRCUITS)
LOCATE AT FIRE
ALARM ENTRANCE
GROUND FLOOR
2-CONDUCTOR 18GA
CABLE & (2) RS-485
RF TAPPER - LOW PIM (-161dBc), 340-5850MHz, N-FEMALE, 300W
(PROVIDE QUANTITY AND COUPLING DB RATING AS REQUIRED
FOR A COMPLETE AND OPERABLE SYSTEM) (TYPICAL)
1ST FLOOR
2ND FLOOR
DAS ANTENNAS (SEE FLOOR
PLANS FOR QUANTITIES AND
LOCATIONS) (TYPICAL)
1/2 INCH COAX CABLE
T
DAS
T
DAS
T
TO
ADDITIONAL
DEVICES
1/2 INCH COAX CABLE
T
DAS
T
DAS
T
TO
ADDITIONAL
DEVICES
PUBLIC SAFETY RADIO
DONOR ANTENNA
ANTENNA MAST - BOND
TO BUILDING STEEL
LIGHTNING ARRESTOR - PROVIDE GROUND, LOCATE
OUTSIDE BEFORE CABLE BUILDING ENTRY
1/2 INCH COAX CABLE OUTDOOR
ROOF
J
H N
F RAIN
E
P R
O F
ES S ION A L ENG
I N
E E
R
L I CENSE
F
LO R I D A
STATE OF
No. 90063
O
REDERICK
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120
FULLY SPRINKLERED305 East Dr., Suite H, Melbourne, Florida 32904
PH: 321.345.9026
B
IM
/0
P o lic e
R a d io s U p g ra d e
S a lis b u ry /0
P o lic e R a d io s U p g ra d e R
D iv
.r v t
/2 /2
:3
:2
P
M
EP101
BUILDING 1 FLOOR PLANS - POWER POLICE RADIOS UPGRADE
SALISBURY, NC
659-20-200
12/21/21 BMS SDL
100% CONSTRUCTION
DOCUMENTS
CODED NOTES:
WALL MOUNTED REMOTE BI-DIRECTIONAL ANTENNA (BDA).
WALL MOUNTED BATTERY BACKUP POWER SUPPLY.
WALL MOUNTED BDA ANNUNCIATOR.
PER NFPA 1221 SECTION 9.6.2.1, BACKBONE, ANTENNA DISTRIBUTION, RADIATING, OR ANY FIBER OPTIC CABLES SHALL BE RATED AS PLENUM CABLES. PER NFPA SECTION 9.6.2.3, BACKBONE CABLES SHALL BE ROUTED THROUGH AN ENCLOSURE THAT MATCHES THE BUILDING'S FIRE RATING. PER NFPA 1221 SECTION 9.6.2.4, THE CONNECTION BETWEEN THE BACKBONE CABLE AND THE ANTENNA CABLES SHALL BE MADE WITHIN AN ENCLOSURE THAT MATCHES THE BUILDING'S FIRE RATING, AND
PASSAGE OF THE ANTENNA DISTRIBUTION CABLE IN AND OUT OF THE ENCLOSURE SHALL BE
FIRESTOPPED. EXACT CABLE ROUTING SHALL BE DETERMINED BY THE CONTRACTOR.
DRAWING NOTES:
1. DISTRIBUTED ANTENNA SYSTEM (DAS) DEVICE LAYOUT IS PROVIDED FOR INFORMATIONAL PURPOSES TO ASSIST THE AUTHORITY HAVING JURISDICTION DURING THE REVIEW PROCESS, AND TO ASSIST CONTRACTOR(S) DURING THE PROPOSAL CYCLE. STATE CERTIFIED AND LICENSED BI-DIRECTIONAL
AMPLIFIER (BDA) SYSTEM CONTRACTOR SHALL SUBMIT ENGINEERED SIGNED AND SEALED SHOP
DRAWINGS WITH EXACT DEVICE QUANTITIES AND LAYOUTS TO AUTHORITY HAVING JURISDICTION
COMPLYING WITH STATE AND LOCAL CODES/STANDARDS.
2. DISTRIBUTED ANTENNA SYSTEM (DAS) COVERAGE SHALL MEET THE REQUIREMENTS OF NFPA 1221, INCLUDING BUT NOT LIMITED TO:
A. NFPA 1221 SECTION 9.6.7.4 - GENERAL BUILDING AREAS SHALL BE PROVIDED WITH 90 PERCENT
FLOOR AREA RADIO COVERAGE.
B. NFPA 1221 SECTION 9.6.7.3 - CRITICAL AREAS INCLUDING FIRE COMMAND CENTERS, FIRE PUMP
ROOMS, EXIT PASSAGEWAYS, ELEVATOR LOBBIES, STANDPIPE CABINETS, SPRINKLER SECTIONAL VALVE LOCATIONS, AND OTHER AREAS DEEMED CRITICAL BY THE AHJ, SHALL BE PROVIDED WITH
99 PERCENT FLOOR AREA RADIO COVERAGE.
3. SEE CONDUIT PENETRATION OF FIREWALL DETAIL ON SHEET E-501 FOR FIREWALL PENETRATION
REQUIREMENTS.
1/16" = 1'-0"EP101
2 B1 FIRST FLOOR - POWER
1/16" = 1'-0"EP101
3 B1 GROUND FLOOR - POWER
1/16" = 1'-0"EP101
1 B1 SECOND FLOOR - POWER
0 8' 16' 32' 48'
1/16" = 1'-0"
B1-G,B1-1,B1-2
N.T.S.EP101
4 BUILDING 1 IN-BUILDING PUBLIC SAFETY RADIO ENHANCEMENT SYSTEM
N
G062
GENERAL STORAGE
442 SF
G059
AUTOPSY SUITE
446 SF
GO56
MORGUE RECEIVING
324 SF
G055
TOILET
135 SF
G061
CORRIDOR
288 SF
G070
BULK STOR.
659 SF
G058
UNEXCAVATED
G071
GEN STORAGE
94 SF
G032
TRANSFORMER
491 SF
G079
GAS STOR
117 SF
G080
CHEM.
70 SF
G028
MRI EXAM/SCAN
309 SF
G031
EMERG GEN
51 SF
G009
MECHANICAL ROOM
G010
CLEAN SUPPLY
169 SF
G063
ELEV LOBBY
223 SF
G013
M. SHOWER
182 SF
G014
MALE LOCK.
227 SF
G016
GENERAL STORAGE
672 SF
G017A
MECHANICAL
G017
UNEXCAVATED
G011
F. LOCK. RM
161 SF
G019
UNEXCAVATED
G068
STOR.
96 SF
G0201
ELECTRICAL
G019A
FIRE ALARM EQUIP
22 SF
G
E L E
C C
L
S
F
G012
F. SHOWER
182 SF
G
E L E
C C
L
G060
MECH
39 SF
UNEXCAVATED
G028G
COMP RM
176 SF
G028E
COMPUTER RM
157 SF
G028D
WAITING
164 SF
G028A
VEST
114 SF
G028C
HC TOILET
47 SF
G028B
STORAGE
57 SF
G070A
BULK STOR.
146 SF
G020E
TOILET
50 SF
GO20F
STAFF
112 SF
G020G
OFFICE
90 SF
G020H
CONTROL
224 SF
G020J
MRI EXAM
491 SF
G020
WAITING ROOM
334SF
G020L
MECHANICAL
88 SF
G020M
EQUIP STOR
113 SF
G020 i
EQUIP STORAGE
G020K
GEN STORAGE
100 SF
GO20 D
TLT/DRESS
58 SF
GO20P
SUB WAIT
69 SF
G020A
HOLD
150 SF
G020D
HALL
71 SF
G070
FEC
GO48
CORRIDOR
GO18
CORRIDOR
GO30
CORRIDOR
GO54
CORRIDOR
G003B
SPD STORAGE
G003A
SPD BREAKDOWN
G006
TOILET
G005
PATIENT EFFECTS
G004
LOGISTICS
G005A
VALUABLE
STORAGE
G004A
OFFICE
G004B
OFFICE
G083
STERILE STORAGE
117 SF
G086
BREAKOUT RECEIVING
136 SF
G091B
STORAGE
102 SF
G091A
VESTIBULE
82 SF
G091
SHIPPING AND RECEIVING
186 SF
G085
MALE
123 SF
G084
FEMALE
110 SF
G081
ETO
131 SF
G080
PREP & PACK
-- SF
G074
DECONTAM
-- SF
G045
DISPATCH
-- SF
G045
STORAGE
55 SF
G
A U
T O
C A
R T
W A
S H
S
F
G075
CORRIDOR
-- SF
G076
EQUIP WASH
109 SF
G072
DETERGENT RM
145 SF
G050
LINEN
86 SF
GO40
OFFICE
136 SF
G038
DECONTAM
165 SF
G039
OFFICE
125 SF
G037
CONFERENCE
277 SF
G035
SOILED RECEIVING
179 SF
G049
LOADING DOCK
D N
D N
LOADING DOCK
D N
D N
DASDASDASDASDASDAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DASDASDASDASDAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
TUNNEL 'G' (SEE BUILDING NO. 20
GROUND FLOOR PLAN ON SHEET EP122
FOR DETAILED VIEW)
TUNNEL 'F'BUILDING
NO. 4
BUILDING
NO. 3
TUNNEL 'H'
BUILDING
NO. 5
EXISTING FIRE ALARM
CONTROL PANEL
FACP-02
UP THROUGH CHASE TO PENTHOUSE -
SEE BUILDING 2 PENTHOUSE PLAN ON
SHEET EP107 FOR CONTINUATION
SEE BUILDING 5 GROUND
FLOOR PLAN ON SHEET EP113
FOR CONTINUATION
SEE BUILDING 3 GROUND
FLOOR PLAN ON SHEET
EP108 FOR CONTINUATION
BUILDING 20 (SEE DRAWING
EP122 FOR ADDITIONAL DETAILS)
(TYPICAL FOR 3)
(TYPICAL FOR 2)
J
H N
F RAIN
E
P R
O F
ES S ION A L ENG
I N
E E
R
L I CENSE
F
LO R I D A
STATE OF
No. 90063
O
REDERICK
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120
FULLY SPRINKLERED305 East Dr., Suite H, Melbourne, Florida 32904
PH: 321.345.9026
B
IM
/0
P o lic e
R a d io s U p g ra d e
S a lis b u ry /0
P o lic e R a d io s U p g ra d e R
D iv
.r v t
/2 /2
:3
:2
P
M
EP102
BUILDING 2 GROUND FLOOR PLAN -
POWER
POLICE RADIOS UPGRADE
SALISBURY, NC
659-20-200
12/21/21 BMS SDL
100% CONSTRUCTION
DOCUMENTS
CODED NOTES:
SUGGESTED FIBER ROUTING, COORDINATE EXACT ROUTING WITH COR PRIOR TO INSTALLATION.
WALL MOUNTED FIBER SPLICE ENCLOSURE ABOVE ACCESSIBLE CEILING.
DRAWING NOTES:
1. DISTRIBUTED ANTENNA SYSTEM (DAS) DEVICE LAYOUT IS PROVIDED FOR INFORMATIONAL
PURPOSES TO ASSIST THE AUTHORITY HAVING JURISDICTION DURING THE REVIEW PROCESS, AND TO ASSIST CONTRACTOR(S) DURING THE PROPOSAL CYCLE. STATE CERTIFIED AND LICENSED BI-
DIRECTIONAL AMPLIFIER (BDA) SYSTEM CONTRACTOR SHALL SUBMIT ENGINEERED SIGNED AND
SEALED SHOP DRAWINGS WITH EXACT DEVICE QUANTITIES AND LAYOUTS TO AUTHORITY HAVING JURISDICTION COMPLYING WITH STATE AND LOCAL CODES/STANDARDS. BUILDING 2 IN-BUILDING
PUBLIC SAFETY RADIO ENHANCEMENT SYSTEM RISER IS LOCATED ON DRAWING EP107.
2. DISTRIBUTED ANTENNA SYSTEM (DAS) COVERAGE SHALL MEET THE REQUIREMENTS OF NFPA 1221, INCLUDING BUT NOT LIMITED TO:
A. NFPA 1221 SECTION 9.6.7.4 - GENERAL BUILDING AREAS SHALL BE PROVIDED WITH 90 PERCENT
FLOOR AREA RADIO COVERAGE.
B. NFPA 1221 SECTION 9.6.7.3 - CRITICAL AREAS INCLUDING FIRE COMMAND CENTERS, FIRE PUMP
ROOMS, EXIT PASSAGEWAYS, ELEVATOR LOBBIES, STANDPIPE CABINETS, SPRINKLER SECTIONAL VALVE LOCATIONS, AND OTHER AREAS DEEMED CRITICAL BY THE AHJ, SHALL BE PROVIDED WITH
99 PERCENT FLOOR AREA RADIO COVERAGE.
3. SEE BUILDING 2 IN-BUILDING PUBLIC SAFETY RADIO ENHANCEMENT SYSTEM DIAGRAM ON SHEET
EP107.
4. SEE CONDUIT PENETRATION OF FIREWALL DETAIL ON SHEET E-501 FOR FIREWALL PENETRATION
REQUIREMENTS.
1/16" = 1'-0"EP102
1 B2 GROUND FLOOR - POWER
0 8' 16' 32' 48'
1/16" = 1'-0"
B2-G,T-F,T-G,T-H
FEC
DENTAL LAB
DENTAL O
P #8
STAIRS #4
1147A
DENTAL O
P #7
DENTAL BREAK
FIRE CLS
1141A
DENTAL O
P #5
1149A
DENTAL O
P #6
1149B
DENTAL O
P #4
DENTAL STORAGE
CLEAN S
TOR.
DENTAL O
P#3
DENTAL O
P#2
DENTAL
PHARMACY
EXAM
VAULT
STAIRS
1157A
ELEC. CLS
PHARMACY
ELEC
STORAGE
D U
M B
W A
IT
E
R S
OFFICE
CLINIC
OFFICE
OFFICE
1009B
WAITING AREA
CONF ROOM
STORAGE
LOBBY
RECEPTION
EXAM
EXAM
NURSE
EXAM
1167A
TOILET
EXAM
EXAM
BREAK RM
OFFICE
OFFICE
EXAM
EXAM
1006A
EXAM
1007A
STOR
1010A
ELEC
FEC
OFFICE
STAIRS
T O
IL
E T
CLEAN SUPPLY
OFFICE
OFFICE
STOR.
STOR.
STAIRS
TOILET
ELEC.
M.O.D. OFFICE
IV STORAGE
S T
O R
A G
E
M C
L O
S E
T
OFFICE
OFFICE
OFFICE
OFFICE
1096B
OFFICE
OFFICE
STORAGE
OFFICE
OFFICE
TOILET
TOILET
MED ROOM
LOCKERS
CLEAN LINEN
EXAM
EXAM
EXAM
1083STORAGE23
1084A
TOIL/SHWR
OFFICE
STAIRS
LOUNGE
TOILET
HOLDING
EXAM
EXAM
TOILET
1064STORAGE10
OFFICE
VESTIBULE
1070ELEC.27
OBSERVATION
1081STORAGE23
X X
X X
X X
X X
X
1065CLOSET11
1066UTILITY40
1188A
ELECT.
1190A
TELE
TELE. CLS
1170A
SOILED UTILITY
1009C
OFFICE
STOR.
STOR.
OFFICE
OFFICE
1D147
PROCEDURE
1D147B
MED
1D111
CLEAN
1D112
TOILET
1D113
STORAGE
1D114
CONSULT
1D115
CONSULT
1D116
CONSULT
1D117
EXAM
1D118
EXAM
1D113A
TELE
1D147A
TOILET
1D146
ELEC
1D142
SOILED
1D143
SPD
1D144
CLEAN LINEN
1D150
TOILET
C1-15
CORR
1D151
LOUNGE
C1-14
CORR
1D104
WOMEN
1D105
MEN
C1-11
CORR
1D103
MECH
1D102
HAC
1D101D
TOILET
1D101C
DR. OFFICE
1D131
CONFERENCE
1D130
EXAM
1D129
EXAM
1D128
EXAM
1D127
EXAM
1D126
EXAM
1D125
EXAM
1D124
EXAM
1D123
EXAM
1D122
EXAM
1D121
EXAM
1D120
EXAM
1D145A
STORAGE
1D141
OFFICE
1D140
OFFICE
1D145
H. A. S.
1D110 screening
1D106
WAITING
1D101
PASSAGE
1D101B
A. O.
1D101A
SECRETARY
1D100B
OFFICE
C1-12
VESTIBULE
C1-12
CORR
LINEN
RN ALCOVE
1096D
CLEAN SUPPLY
1096C
WAITING
1096A
OFFICE
961101A
STORAGE
STORAGE
ELEC
1159A
WAITING
1159B
OFFICE
1159C
CORRIDOR
1D100A
OFFICE
1140A
DIR
TY
GEN STORAGE
CLEAN SUPPLY
EXAM
EXAM
EXIT CORR
OFFICE
OFFICE
EXAM
EXAM
OFFICE
CORR
WAITING
HOLDING
POLICE
VESTIBULE
CORR
M TLT
F TLT
AOD
HALLWAY
1050A
ELEC
FAC
HALLWAY
OFFICE
DENTAL O
P #9
DENTAL X-R
AY
FEC
LINEN CHUTE
LINEN CHUTE
1192A
ELECT.
TOILET
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
C1-13
CORR
CORRIDOR
CORRIDOR
GEN STORAGE
LOBBY
RECEPTION
TOILET
LOBBY
M. TOILET
Cafe Shop
Canteen Service
STAIRS
B-1
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DASDASDASDAS
DAS
DASDAS
DAS
DAS
DAS
DASDASDASDASDAS
DAS
DASDASDAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
UP THROUGH CHASE FROM
GROUND FLOOR TO PENTHOUSE
J
H N
F RAIN
E
P R
O F
ES S ION A L ENG
I N
E E
R
L I CENSE
F
LO R I D A
STATE OF
No. 90063
O
REDERICK
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120
FULLY SPRINKLERED305 East Dr., Suite H, Melbourne, Florida 32904
PH: 321.345.9026
B
IM
/0
P o lic e
R a d io s U p g ra d e
S a lis b u ry /0
P o lic e R a d io s U p g ra d e R
D iv
.r v t
/2 /2
:3
:2
P
M
EP103
BUILDING 2 FIRST FLOOR PLAN -
POWER
POLICE RADIOS UPGRADE
SALISBURY, NC
659-20-200
12/21/21 BMS SDL
100% CONSTRUCTION
DOCUMENTS
CODED NOTES:
WALL MOUNTED BDA ANNUNCIATOR. LOCATE AT FIRE ALARM ENTRANCE.1
DRAWING NOTES:
1. DISTRIBUTED ANTENNA SYSTEM (DAS) DEVICE LAYOUT IS PROVIDED FOR INFORMATIONAL
PURPOSES TO ASSIST THE AUTHORITY HAVING JURISDICTION DURING THE REVIEW PROCESS, AND TO ASSIST CONTRACTOR(S) DURING THE PROPOSAL CYCLE. STATE CERTIFIED AND LICENSED BI-
DIRECTIONAL AMPLIFIER (BDA) SYSTEM CONTRACTOR SHALL SUBMIT ENGINEERED SIGNED AND
SEALED SHOP DRAWINGS WITH EXACT DEVICE QUANTITIES AND LAYOUTS TO AUTHORITY HAVING JURISDICTION COMPLYING WITH STATE AND LOCAL CODES/STANDARDS. BUILDING 2 IN-BUILDING
PUBLIC SAFETY RADIO ENHANCEMENT SYSTEM RISER IS LOCATED ON DRAWING EP107.
2. DISTRIBUTED ANTENNA SYSTEM (DAS) COVERAGE SHALL MEET THE REQUIREMENTS OF NFPA 1221, INCLUDING BUT NOT LIMITED TO:
A. NFPA 1221 SECTION 9.6.7.4 - GENERAL BUILDING AREAS SHALL BE PROVIDED WITH 90 PERCENT
FLOOR AREA RADIO COVERAGE.
B. NFPA 1221 SECTION 9.6.7.3 - CRITICAL AREAS INCLUDING FIRE COMMAND CENTERS, FIRE PUMP
ROOMS, EXIT PASSAGEWAYS, ELEVATOR LOBBIES, STANDPIPE CABINETS, SPRINKLER SECTIONAL VALVE LOCATIONS, AND OTHER AREAS DEEMED CRITICAL BY THE AHJ, SHALL BE PROVIDED WITH
99 PERCENT FLOOR AREA RADIO COVERAGE.
3. SEE BUILDING 2 IN-BUILDING PUBLIC SAFETY RADIO ENHANCEMENT SYSTEM DIAGRAM ON SHEET
EP107.
4. SEE CONDUIT PENETRATION OF FIREWALL DETAIL ON SHEET E-501 FOR FIREWALL PENETRATION
REQUIREMENTS.
1/16" = 1'-0"EP103
1 B2 FIRST FLOOR - POWER
0 8' 16' 32' 48'
1/16" = 1'-0"
B2-1
STAIRS
XRAY
CONTROL RM
DRESSING
XRAY
CONT RM
DRESSING
XRAY
FILM PROCESS
WORK ROOM
CT SCANNER
XRAY
HALLWAY
CT OPER.
CLEAN STOR
2110A
OFFICE
2110B
OFFICE
EXAM
TOILET
2110C
WAITING
NUC MED
NUC MED
CONFERENCE
WAITING ROOM
OFFICE
2098A
OFFICE
2098B
OFFICE
2098C
OFFICE
2098D
OFFICE
2098E
OFFICE
2098F
OFFICE
OFFICE
OFFICE
GEN STOR
TOILET
TOILET
D/W
EXAM
EXAM
EXAM
OFFICE
OFFICE
TLT
STAIRS
WAITING ROOM
TOILET
GEN STOR
TOILET
OFFICE
OFFICE
TLT
OFFICE
OFFICE
TLT
EXAM
FEC
TOILET
EXAM
CLEAN SUP
48 2058
TOILET
OFFICE
HAC
TLT
CLOSET
2059A
TOILET
EXAM
EXAM
OFFICE
LOCK
COMPUTER ROOM
LINEN CHUTE
17 2161
OFFICE
OFFICE
LOCKERS
TOILET
LOCKERS
TLT
ELECT
TOILET
2168A
TEL
STORAGE
TOIL.
TLT
TLT
TLT
OFFICE
HAC
CONT RM
2130A
ELECT
FEC
ELECT.
2098G
BATHROOM
2095A
GEN STOR.
2098H
RECEPT.
FAC
WAITING
2152107A
HOT LAB
2090A
OFFICE
BONE DENS
EXAM
2027A
Corridor
CT SCANNER 2
HAC
CORRIDOR
LAB
LAB
FEMALE ST. TLT
LOCKERS
M A
L E
S T . T
L T2047
ST BREAK AREA
S T W
K S
T N
O F F
IC
E
CHIEF OFFICE
OFFICE
OFFICE
OFFICE
CORRIDOR
OFFICE
2035A
HALL W
AY
H A
L L W
A Y
HALL WAY
2030A
TECH WKSTN
BLOOD STAGING
SPECIMEN TLT
SPECIMEN TLT2029
WAITING
BLOOD DRAW
BLOOD DRAW
BLOOD DRAW
TELE
STORAGE
2133A
ELE CLST
CORRIDOR
ELEC
CORRIDOR
CORRIDOR
FEC
STAIRS
STAIRS
LINEN CHUTE
2161A
OFFICE
ECHO
READING
TREADMILL 1
TREADMILL 2
STORAGE
NURSE
WORK
EXISTING
TOILET
EXAM
EXAM
EXAM
FLEX
SPACE
EKG
HOLTER
EKG
EXAM
EXAM
ECHO 2
ECHO WORK
STORAGE
ECHO 1
PHYS.
WKRM
ASST.
CHIEF
C O
R R
ID
O
R
145 SF
266 SF
243 SF
34 SF
94 SF
34 SF
159 SF
152 SF
143 SF
115 SF
165 SF
148 SF
137 SF
143 SF
177 SF
80 SF
77 SF
166 SF
164 SF
115 SF
PIPE CHASE
Blood Gas Analyzer
SPS
Equipment Storage
Inpatient Supv.
Respiratory Staff
STAIRS
2098I
CLOSET
ROOF
WAITING
STAIRS
ROOF
FEC
STAIRS
XRAY
CONTROL RM
DRESSING
XRAY
CONT RM
DRESSING
XRAY
FILM PROCESS
WORK ROOM
CT SCANNER
XRAY
HALLWAY
CT OPER.
CLEAN STOR
2110A
OFFICE
2110B
OFFICE
EXAM
TOILET
2110C
WAITING
NUC MED
NUC MED
CONFERENCE
WAITING ROOM
OFFICE
2098A
OFFICE
2098B
OFFICE
2098C
OFFICE
2098D
OFFICE
2098E
OFFICE
2098F
OFFICE
OFFICE
OFFICE
GEN STOR
TOILET
TOILET
D/W
EXAM
EXAM
EXAM
OFFICE
OFFICE
TLT
STAIRS
WAITING ROOM
TOILET
GEN STOR
TOILET
OFFICE
OFFICE
TLT
OFFICE
OFFICE
TLT
EXAM
FEC
TOILET
EXAM
CLEAN SUP
48 2058
TOILET
OFFICE
HAC
TLT
CLOSET
2059A
TOILET
EXAM
EXAM
OFFICE
LOCK
COMPUTER ROOM
LINEN CHUTE
17 2161
OFFICE
OFFICE
LOCKERS
TOILET
LOCKERS
TLT
ELECT
TOILET
2168A
TEL
STORAGE
TOIL.
TLT
TLT
TLT
OFFICE
HAC
CONT RM
2130A
ELECT
FEC
ELECT.
2098G
BATHROOM
2095A
GEN STOR.
2098H
RECEPT.
FAC
WAITING
2152107A
HOT LAB
2090A
OFFICE
BONE DENS
EXAM
2027A
Corridor
CT SCANNER 2
HAC
CORRIDOR
LAB
LAB
FEMALE ST. TLT
LOCKERS
M A
L E
S T . T
L T2047
ST BREAK AREA
S T W
K S
T N
O F F
IC
E
CHIEF OFFICE
OFFICE
OFFICE
OFFICE
CORRIDOR
OFFICE
2035A
HALL W
AY
H A
L L W
A Y
HALL WAY
2030A
TECH WKSTN
BLOOD STAGING
SPECIMEN TLT
SPECIMEN TLT2029
WAITING
BLOOD DRAW
BLOOD DRAW
BLOOD DRAW
TELE
STORAGE
2133A
ELE CLST
CORRIDOR
ELEC
CORRIDOR
CORRIDOR
FEC
STAIRS
STAIRS
LINEN CHUTE
2161A
OFFICE
ECHO
READING
TREADMILL 1
TREADMILL 2
STORAGE
NURSE
WORK
EXISTING
TOILET
EXAM
EXAM
EXAM
FLEX
SPACE
EKG
HOLTER
EKG
EXAM
EXAM
ECHO 2
ECHO WORK
STORAGE
ECHO 1
PHYS.
WKRM
ASST.
CHIEF
C O
R R
ID
O
R
145 SF
266 SF
243 SF
34 SF
94 SF
34 SF
159 SF
152 SF
143 SF
115 SF
165 SF
148 SF
137 SF
143 SF
177 SF
80 SF
77 SF
166 SF
164 SF
115 SF
PIPE CHASE
Blood Gas Analyzer
SPS
Equipment Storage
Inpatient Supv.
Respiratory Staff
STAIRS
2098I
CLOSET
ROOF
WAITING
STAIRS
ROOF
FEC
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
UP THROUGH CHASE FROM
GROUND FLOOR TO PENTHOUSE
J
H N
F RAIN
E
P R
O F
ES S ION A L ENG
I N
E E
R
L I CENSE
F
LO R I D A
STATE OF
No. 90063
O
REDERICK
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120
FULLY SPRINKLERED305 East Dr., Suite H, Melbourne, Florida 32904
PH: 321.345.9026
B
IM
/0
P o lic e
R a d io s U p g ra d e
S a lis b u ry /0
P o lic e R a d io s U p g ra d e R
D iv
.r v t
/2 /2
:3
:2
P
M
EP104
BUILDING 2 SECOND FLOOR PLAN -
POWER
POLICE RADIOS UPGRADE
SALISBURY, NC
659-20-200
12/21/21 BMS SDL
100% CONSTRUCTION
DOCUMENTS
DRAWING NOTES:
1. DISTRIBUTED ANTENNA SYSTEM (DAS) DEVICE LAYOUT IS PROVIDED FOR INFORMATIONAL
PURPOSES TO ASSIST THE AUTHORITY HAVING JURISDICTION DURING THE REVIEW PROCESS, AND TO ASSIST CONTRACTOR(S) DURING THE PROPOSAL CYCLE. STATE CERTIFIED AND LICENSED BI-
DIRECTIONAL AMPLIFIER (BDA) SYSTEM CONTRACTOR SHALL SUBMIT ENGINEERED SIGNED AND
SEALED SHOP DRAWINGS WITH EXACT DEVICE QUANTITIES AND LAYOUTS TO AUTHORITY HAVING JURISDICTION COMPLYING WITH STATE AND LOCAL CODES/STANDARDS.BUILDING 2 IN-BUILDING
PUBLIC SAFETY RADIO ENHANCEMENT SYSTEM RISER IS LOCATED ON DRAWING EP107.
2. DISTRIBUTED ANTENNA SYSTEM (DAS) COVERAGE SHALL MEET THE REQUIREMENTS OF NFPA 1221, INCLUDING BUT NOT LIMITED TO:
A. NFPA 1221 SECTION 9.6.7.4 - GENERAL BUILDING AREAS SHALL BE PROVIDED WITH 90 PERCENT
FLOOR AREA RADIO COVERAGE.
B. NFPA 1221 SECTION 9.6.7.3 - CRITICAL AREAS INCLUDING FIRE COMMAND CENTERS, FIRE PUMP
ROOMS, EXIT PASSAGEWAYS, ELEVATOR LOBBIES, STANDPIPE CABINETS, SPRINKLER SECTIONAL VALVE LOCATIONS, AND OTHER AREAS DEEMED CRITICAL BY THE AHJ, SHALL BE PROVIDED WITH
99 PERCENT FLOOR AREA RADIO COVERAGE.
3. SEE BUILDING 2 IN-BUILDING PUBLIC SAFETY RADIO ENHANCEMENT SYSTEM DIAGRAM ON SHEET
EP107.
4. SEE CONDUIT PENETRATION OF FIREWALL DETAIL ON SHEET E-501 FOR FIREWALL PENETRATION
REQUIREMENTS.
1/16" = 1'-0"EP104
1 B2 SECOND FLOOR - POWER
0 8' 16' 32' 48'
1/16" = 1'-0"
B2-2
PAT. ROOM
3059A
PAT. TLT
PAT. ROOM
3058A
PAT. TLT
3045A
EQUIP
CORRIDOR
EQUIP STOR
CLEAN SUP
NOURISHMENT
PAT ROOM
3054A
PAT. TLT
PAT ROOM
3039A
PAT. TLT
3045B
CORRIDOR
PAT ROOM 3040A
PAT. TLT
MED ROOM
SOIL UTIL
PAT ROOM
3042A
PAT. TLT
BARIATRIC PAT. ROOM
3051A
BAR. PAT TLT
PAT ROOM 3043B
PAT. TLT
ISO. PAT. ROOM
ANTE ISOL
3050A
PAT. TLT
ISO. PAT. ROOM
ANTE ISOL
3044B
PAT. TLT
3043A
STAIR
3044A
STAIR
Dialysis
NURSE STATION
EQUIP STOR
WAITING
LAB.STO
F.TLT
TLT
MSCU ISOL
1-BED
1603033
TLT
TLT
1-BED
1-BED
1603029
TLT
TLT
463027
1-BED
1-BED
BREAKRM
EQUIP STOR
TLT
TLT
M.TLT
M.TLT
1-BED
1-BED
TLT
F. TLT
1-BED
1-BED
Staff Workroom
BARIATRIC RM
342 SF
OFFICE
3101A
OFFICE
CONF
EQUIP STOR
CLEAN SUP
EKG
ICE
1-BED
STOR
81 3091A
TEL
CLEAN SUP
TLT
M.TLT
EQUIP STO
M.TLT
HAC
ELEC
42 3179
FAC
63036
CORR
CORR
3001A
STAIR #1
3165A
FAC
STAIR #6
PATIENT RM
PATIENT RM
305 SF
PATIENT RM
320 SF
PATIENT RM
299 SF
PATIENT RM
293 SF
PATIENT RM
295 SF
PATIENT RM
323 SF
MECH
95 SF
HAC
57 SF
CLEAN WK.RM.
195 SF
STAFF WK.RM
342 SF
MEDICATION
138 SF
SOIL LINEN
138 SF
C. LINEN
130 SF
STO. EMS
67 SF 3103
NOURISHMNET
118 SF
S. LOCKER
174 SF
OFFICE
139 SF
PATIENT RM
300 SF
PATIENT RM
288 SF
PATIENT RM
280 SF
PATIENT RM
275 SF
PATIENT RM
270 SF
PATIENT RM
268 SF
PATIENT RM
337 SF
3121A
STO.
124 SF
EQ STO
162 SF
383 SF
BARIATRIC RM
309 SF
BARIATRIC RM
PAT. ROOM
260 SF
PAT. ROOM
256 SF
PAT. ROOM
254 SF
PAT. ROOM
153 SF
6068A
PAT. TLT
44 SF
ANT. ISO
PAT. ROOM
153 SF
6066A
PAT. TLT
42 SF
ANT. ISO
40 SF
PAT. ROOM
177 SF
3064A
PAT. ROOM
PAT. ROOM
207 SF
3063A
PAT. ROOM
3186.
MEDICATION
TLT
EQUIP STORAGE
100 SF
HAC
CORRIDOR
STAIR #3
227 SF
3190F
3190L
ED. OFC
3190E
UM NURSES
3190G
CHIEF
3190H
CHIEF NURSE
3190I
NURSE MANAGER
3190J
NURSE MANAGER
3190K
CONSULT
3190D
ASST CHIEF NURSE
3190C
SOCIAL WORKER
3190B
PHARM_TECH
3190A
COPY/FAX
CORRIDOR
UM NURSES
UM NURSES
UM NURSES
38/48H
38/48H
38/24H
38/24H
38/24H 38/24H
38/48H
70/48N
64 64
C
TTTT
DOWN
UP
DOW
N
UP
DOWN
UP
DOW
N
UP
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
UP THROUGH CHASE FROM
GROUND FLOOR TO PENTHOUSE
J
H N
F RAIN
E
P R
O F
ES S ION A L ENG
I N
E E
R
L I CENSE
F
LO R I D A
STATE OF
No. 90063
O
REDERICK
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120
FULLY SPRINKLERED305 East Dr., Suite H, Melbourne, Florida 32904
PH: 321.345.9026
B
IM
/0
P o lic e
R a d io s U p g ra d e
S a lis b u ry /0
P o lic e R a d io s U p g ra d e R
D iv
.r v t
/2 /2
:3
:3
P
M
EP105
BUILDING 2 THIRD FLOOR PLAN -
POWER
POLICE RADIOS UPGRADE
SALISBURY, NC
659-20-200
12/21/21 BMS SDL
100% CONSTRUCTION
DOCUMENTS
DRAWING NOTES:
1. DISTRIBUTED ANTENNA SYSTEM (DAS) DEVICE LAYOUT IS PROVIDED FOR INFORMATIONAL
PURPOSES TO ASSIST THE AUTHORITY HAVING JURISDICTION DURING THE REVIEW PROCESS, AND TO ASSIST CONTRACTOR(S) DURING THE PROPOSAL CYCLE. STATE CERTIFIED AND LICENSED BI-
DIRECTIONAL AMPLIFIER (BDA) SYSTEM CONTRACTOR SHALL SUBMIT ENGINEERED SIGNED AND
SEALED SHOP DRAWINGS WITH EXACT DEVICE QUANTITIES AND LAYOUTS TO AUTHORITY HAVING JURISDICTION COMPLYING WITH STATE AND LOCAL CODES/STANDARDS. BUILDING 2 IN-BUILDING
PUBLIC SAFETY RADIO ENHANCEMENT SYSTEM RISER IS LOCATED ON DRAWING EP107.
2. DISTRIBUTED ANTENNA SYSTEM (DAS) COVERAGE SHALL MEET THE REQUIREMENTS OF NFPA 1221, INCLUDING BUT NOT LIMITED TO:
A. NFPA 1221 SECTION 9.6.7.4 - GENERAL BUILDING AREAS SHALL BE PROVIDED WITH 90 PERCENT
FLOOR AREA RADIO COVERAGE.
B. NFPA 1221 SECTION 9.6.7.3 - CRITICAL AREAS INCLUDING FIRE COMMAND CENTERS, FIRE PUMP
ROOMS, EXIT PASSAGEWAYS, ELEVATOR LOBBIES, STANDPIPE CABINETS, SPRINKLER SECTIONAL VALVE LOCATIONS, AND OTHER AREAS DEEMED CRITICAL BY THE AHJ, SHALL BE PROVIDED WITH
99 PERCENT FLOOR AREA RADIO COVERAGE.
3. SEE BUILDING 2 IN-BUILDING PUBLIC SAFETY RADIO ENHANCEMENT SYSTEM DIAGRAM ON SHEET
EP107.
4. SEE CONDUIT PENETRATION OF FIREWALL DETAIL ON SHEET E-501 FOR FIREWALL PENETRATION
REQUIREMENTS.
1/16" = 1'-0"EP105
1 B2 THIRD FLOOR - POWER
0 8' 16' 32' 48'
1/16" = 1'-0"
B2-3
ELECTRICAL
SCRUB
435 SF
OR #1
412 SF
OR #2
EQ. STORAGE
4005 CYSTO
STORAGE
STERILE
SUPPLY
SOIL HOLD
CL
EA
N
CO
RE
NEPTUNE
DOCK
C-ARM
ALCOVE
CO
RR
ID
OR
ROOF
ROOF
RO
OF RO
OF
ROOF
ROOF
RO
OF RO
OF
PH 1 PACU
4100A
EQUIP STORAGE
4100B
EQUIP STORAGE
TOILET
TOILET
STORAGE
SURGERY WAITING
OFFICE
FAC
STAIRS
STAIRS
ELECT CLS
SOILED
TOILET
10000
GEN STORAGE
TOILET
PASS
HAC
TOILET
OFFICE
155 4161
UTILITY
4129A
TOILET
STORAGE
LINEN
4154A
TELE
D/W
PRE OP
4017A
STORAGE
ELECT
EQUIP STORAGE
EQUIPMENT STORAGE
EQUIP STORAGE
OFFICE
EXAM
EXAM
PH 2 RM 3
TLT/SHW
4017B
TLT
EXAM
EXAM
SH
O
W
ER
TO
ILET
TO
ILET
W O
M
EN
'S LO
C
KER
S
C O
R R
ID
O
R 4110B
C O
R R
ID
O
R 4110A
M
EN
'S LO
C
KER
S
SH
O
W
ER
4130A M
EN
'S LO
C
KER
S
C
LEAN
SU
PPLY
SU
PPLIES/
C
LEAN
U
TILITY
STAFF
WORKSTATION
4113PATIEN
T H
O
LD
IN
G
C
ASE C
AR
T H
O
LD
IN
G
M
ED
G
AS
O R
#5
SU
B STER
ILE
SU
R G
IC
AL C
O R
R
ID
O R
O R
#6
O R
#7
SC
R
U B #1
H
AC
STO
R
AG
E #1
ELEC
TR
IC
AL
STO
R
AG
E #2
EQ
U
IPM
EN
T
EQ
U
IPM
EN
T
4129A O
FFIC
E
SO
ILED
U
TILITY
TO
ILET
STAIR
S
LIN
EN
C H
U
TE
M
IN
O R
O R
R
EG
ISTR
ATIO
N
4149 ELEC
C
L
M
IN
O R
O R
4152B
PH 1 PACU
OFFICE
RECEPTION
EQUIP STOR
NURSE STATION
CORRIDOR
STAIRS
CORRIDOR
CORRIDOR
STAIR # 3
ICU
ICU
ICU
ICU
4085H
CHARTING STA.
4085G
CHARTING STA.
4085E
ALCOVE4043
STORAGE
DISTRBUTION
ICU
ICU
4085D
ALCOVE
ICU
ICU
4085B
CHARTING STA.
4085A
CHARTING STA.
BREAKROOM
SOIL UTILITY
MED RM
ANTI
ISO. - ICU
ICU
NOURISHMENT RM
CONTROL
4083A
CHARTING STA.
OFFICE
ICU EQUIP
HAC
4058A
O FFIC E
O FFIC E
O FFIC E
O FFIC E
P ACU
ICU
ICU
ICU
ISO LATIO N- IC U4053
ISO LATIO N- IC U
ICU
ICU
ICU 4047
O FFIC E
R ESP O FFIC E
STO RAG E
D ISTR IBU TIO N
B REAK RO OM
IC U EQ UIP
C LEAN LIN EN
R ESP EQ U IP .
N O UR ISHM EN T RO OM
AN TE
H AC4055
O FFIC E4081
O FFIC E4061
STAFF TO ILET4056
LOC KER RO OM
B ATH
4058A
O N - CALL4058
STO RAG E4059
B REAK /C ON F RO OM
M ED RO OM
SO IL U TILITY
STAIR S # 64167
STAIR # 2
ALC O VE
4085E
ALC O VE4085D
P ACU
Roof
STAIRS
FAC
ROOF
RO
OF
FP
ROOF
ROOF ROOF
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
UP THROUGH CHASE FROM
GROUND FLOOR TO PENTHOUSE
J
H N
F RAIN
E
P R
O F
ES S ION A L ENG
I N
E E
R
L I CENSE
F
LO R I D A
STATE OF
No. 90063
O
REDERICK
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120
FULLY SPRINKLERED305 East Dr., Suite H, Melbourne, Florida 32904
PH: 321.345.9026
B
IM
/0
P o lic e
R a d io s U p g ra d e
S a lis b u ry /0
P o lic e R a d io s U p g ra d e R
D iv
.r v t
/2 /2
:3
:3
P
M
EP106
BUILDING 2 FOURTH FLOOR PLAN -
POWER
POLICE RADIOS UPGRADE
SALISBURY, NC
659-20-200
12/21/21 BMS SDL
100% CONSTRUCTION
DOCUMENTS
DRAWING NOTES:
1. DISTRIBUTED ANTENNA SYSTEM (DAS) DEVICE LAYOUT IS PROVIDED FOR INFORMATIONAL
PURPOSES TO ASSIST THE AUTHORITY HAVING JURISDICTION DURING THE REVIEW PROCESS, AND TO ASSIST CONTRACTOR(S) DURING THE PROPOSAL CYCLE. STATE CERTIFIED AND LICENSED BI-
DIRECTIONAL AMPLIFIER (BDA) SYSTEM CONTRACTOR SHALL SUBMIT ENGINEERED SIGNED AND
SEALED SHOP DRAWINGS WITH EXACT DEVICE QUANTITIES AND LAYOUTS TO AUTHORITY HAVING JURISDICTION COMPLYING WITH STATE AND LOCAL CODES/STANDARDS. BUILDING 2 IN-BUILDING
PUBLIC SAFETY RADIO ENHANCEMENT SYSTEM RISER IS LOCATED ON DRAWING EP107.
2. DISTRIBUTED ANTENNA SYSTEM (DAS) COVERAGE SHALL MEET THE REQUIREMENTS OF NFPA 1221, INCLUDING BUT NOT LIMITED TO:
A. NFPA 1221 SECTION 9.6.7.4 - GENERAL BUILDING AREAS SHALL BE PROVIDED WITH 90 PERCENT
FLOOR AREA RADIO COVERAGE.
B. NFPA 1221 SECTION 9.6.7.3 - CRITICAL AREAS INCLUDING FIRE COMMAND CENTERS, FIRE PUMP
ROOMS, EXIT PASSAGEWAYS, ELEVATOR LOBBIES, STANDPIPE CABINETS, SPRINKLER SECTIONAL VALVE LOCATIONS, AND OTHER AREAS DEEMED CRITICAL BY THE AHJ, SHALL BE PROVIDED WITH
99 PERCENT FLOOR AREA RADIO COVERAGE.
3. SEE BUILDING 2 IN-BUILDING PUBLIC SAFETY RADIO ENHANCEMENT SYSTEM DIAGRAM ON SHEET
EP107.
4. SEE CONDUIT PENETRATION OF FIREWALL DETAIL ON SHEET E-501 FOR FIREWALL PENETRATION
REQUIREMENTS.
1/16" = 1'-0"EP106
1 B2 FOURTH FLOOR - POWER
0 8' 16' 32' 48'
1/16" = 1'-0"
B2-4
TEE/ CARDIO
STA
IR
S
ELEC
IT
ISOLATION
MECH
MECH
CLEAN/ MEDS
NS
N
EW
ELEV.
5008C2
5008B
5008A
PATIENT
TOILET
EQ. STORAGE
HK
1051 SF
HYBRID 2
884 SF
SEMI -
HYBRID 1
SOIL
5007B
NS WORK
STERILE
SUPPLY
STAFF
TOILET
5007A
SCRUB
FEMALE
LOCKERS
MALE
LOCKERS
SCRUB
SOILED
ANESTH.
OFFICE
ELEC
121 SF
EQUIP. STOR
ANTE
5010A
C
LEA
N C
O R
E
TOILET
TOILET
SO
ILED
LIN
EN
C O
R R
ID
O
R
NURSE
MANAGER
5070EQ ALCOVE
STRETCHER
ALCOVE
128 SF
EQ
CORRIDOR
CONTROL
ROOM
5001A
IV MIXTURE
ROOM
U P
A O
V
A O
V
A O
VA
O
V
ALCOVE
LINEN
D U
M B
W A
IT
5068C
OFFICE
STORAGE
ELEC
HEALTH ADMIN.
EXAM #1
EXAM #3
BREAK RM
EXAM #2
FAC
PHARM
HAC
TELE
WAITING
5068A
EXAM
EXAM
5062C
EXAM
5062A
OFFICE
5062B
EXAM
CORRIDOR
CORRIDOR
5029A
5028A
5029A
5025A
525026A
5027C
5027B
5022A
5027A5019
5020A
5019A
5021A
5039 5130
STAIRS
5054A
5055A
52 5054
5052B
5053A
ANTI RM
ISO. RM
51205120
5157B 5157C
NURSE STA
5132A
5027D
5031A
5031A
5034A
5035A
5045A
5043A
DAS DAS DAS DAS
DAS
DAS
DAS
DAS
DAS
DASDASDAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
DAS
PENTHOUSE-2 RADIO ROOM DOWN THROUGH CHASE TO GROUND
FLOOR - SEE BUILDING 2 GROUND FLOOR
PLAN ON SHEET EP102 FOR CONTINUATION
UP THROUGH CHASE FROM GROUND
FLOOR TO PENTHOUSE
B2 PENTHOUSE - POWER3
EP107 1/16" = 1'-0"
MOUNTED ON ROOF ABOVE
EXISTING
PANEL 2L1A2E
2L1A2E-9
2L1A2E-7
24V
BATTERY
MASTER
BDA
AMPLIFIER
BDA
ANNUNCIATOR
PUBLIC SAFETY RADIO
DONOR ANTENNA
ANTENNA MAST - BOND
TO BUILDING STEEL
LIGHTNING ARRESTOR - PROVIDE GROUND, LOCATE
OUTSIDE BEFORE CABLE BUILDING ENTRY
1/2 INCH COAX CABLE OUTDOOR
2L1A2E-7 / 2L1A2E-9
(20A EMERGENCY CIRCUITS)
DAS ANTENNAS (SEE FLOOR
PLANS FOR QUANTITIES AND
LOCATIONS) (TYPICAL)
LOCATE AT FIRE ALARM ENTRANCE
1ST FLOOR
2ND FLOOR
3RD FLOOR
4TH FLOOR
5TH FLOOR
PENTHOUSE
ROOF
2-CONDUCTOR 18GA
CABLE & (2) RS-485
1/2 INCH COAX CABLE
1/2 INCH COAX CABLE
RF TAPPER - LOW PIM
(-161dBc), 340-5850MHz, N-
FEMALE, 300W (PROVIDE
QUANTITY AND COUPLING DB
RATING AS REQUIRED FOR A
COMPLETE AND OPERABLE
SYSTEM) (TYPICAL)
T
DAS
1/2 INCH COAX CABLE
T
1/2 INCH COAX CABLE
T
1/2 INCH COAX CABLE
T
1/2 INCH COAX CABLE
T
T
DAS
T
TO
ADDITIONAL
DEVICES
DAS
T
DAS
T
TO
ADDITIONAL
DEVICES
DAS
T
DAS
T
TO
ADDITIONAL
DEVICES
DAS
T
DAS
T
TO
ADDITIONAL
DEVICES
DAS
T
DAS
T
TO
ADDITIONAL
DEVICES
CORNING 12-FIBER WALL
MOUNT SPLICE ENCLOSURE
INDOOR/OUTDOOR 120 MINUTE FIRE
SURVIVAL STEEL ARMORED GEL-
FILLED PLENUM RATED 12-STRAND
SINGLE MODE OS2 FIBER (1 ACTIVE
STRAND, 11 DARK STRANDS)
(TYPICAL)
TO BUILDING #31 REMOTE BDA UNIT,
BUILDING 31 RISER DRAWING EP124.
INDOOR 120 MINUTE FIRE SURVIVAL
PLENUM RATED 12-STRAND SINGLE
MODE OS2 FIBER (2 STRANDS ROUTED
TO EACH REMOTE UNIT)
CORNING WALL MOUNT ENCLOSURE WITH 12-FIBER
PATCH CASSETTE AND TYPE LC CONNECTORS
FIBER OPTIC PATCH CORD, DUPLEX,
OS2 WITH TYPE LC CONNECTORS
TO BUILDING #20 REMOTE BDA UNIT,
BUILDING 20 RISER DRAWING EP122.
TO BUILDING #7 REMOTE BDA UNIT,
BUILDING 7 RISER DRAWING EP1116.
TO BUILDING #5 REMOTE BDA UNIT,
BUILDING 5 RISER DRAWING EP113.
TO BUILDING #3 REMOTE BDA UNIT,
BUILDING 3 RISER DRAWING EP109.
CONNECT TO FIRE ALARM PANEL FACP-02
(8) SUPERVISORY INPUT MODULES REQUIRED:
• BDA ANTENNA FAILURE
• BDA TROUBLE
• BDA POWER LOSS
• BDA CHARGER TROUBLE
• BDA LOW BATTERY
• ANNUNCIATOR TROUBLE
• PRIMARY/SECONDARY POWER SOURCE INTEGRITY (NFPA 1221 9.1.2.2)
PROVIDE REQUIRED PROGRAMMING TO THE BUILDING FIRE ALARM CONTROL
PANEL. PROVIDE TESTING OF EACH FAULT CONDITION AS PART OF SYSTEM
ACCEPTANCE TESTING.
J
H N
F RAIN
E
P R
O F
ES S ION A L ENG
I N
E E
R
L I CENSE
F
LO R I D A
STATE OF
No. 90063
O
REDERICK
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120
FULLY SPRINKLERED305 East Dr., Suite H, Melbourne, Florida 32904
PH: 321.345.9026
B
IM
/0
P o lic e
R a d io s U p g ra d e
S a lis b u ry /0
P o lic e R a d io s U p g ra d e R
D iv
.r v t
/2 /2
:3
:3
P
M
EP107
BUILDING 2 FIFTH FLOOR PLAN -
POWER
POLICE RADIOS UPGRADE
SALISBURY, NC
659-20-200
12/21/21 BMS SDL
100% CONSTRUCTION
DOCUMENTS
CODED NOTES:
WALL MOUNTED MASTER BI-DIRECTIONAL ANTENNA (BDA).
WALL MOUNTED BATTERY BACKUP POWER SUPPLY.
PER NFPA 1221 SECTION 9.6.2.1, BACKBONE, ANTENNA DISTRIBUTION, RADIATING, OR ANY FIBER OPTIC CABLES SHALL BE RATED AS PLENUM CABLES. PER NFPA SECTION 9.6.2.3, BACKBONE CABLES SHALL BE ROUTED THROUGH AN ENCLOSURE THAT MATCHES THE BUILDING'S FIRE RATING. PER NFPA 1221 SECTION 9.6.2.4, THE CONNECTION BETWEEN THE BACKBONE CABLE AND THE ANTENNA CABLES SHALL BE MADE WITHIN AN ENCLOSURE THAT MATCHES THE BUILDING'S FIRE RATING, AND
PASSAGE OF THE ANTENNA DISTRIBUTION CABLE IN AND OUT OF THE ENCLOSURE SHALL BE
FIRESTOPPED. EXACT CABLE ROUTING SHALL BE DETERMINED BY THE CONTRACTOR.
DRAWING NOTES:
1. DISTRIBUTED ANTENNA SYSTEM (DAS) DEVICE LAYOUT IS PROVIDED FOR INFORMATIONAL
PURPOSES TO ASSIST THE AUTHORITY HAVING JURISDICTION DURING THE REVIEW PROCESS, AND TO ASSIST CONTRACTOR(S) DURING THE PROPOSAL CYCLE. STATE CERTIFIED AND LICENSED BI-
DIRECTIONAL AMPLIFIER (BDA) SYSTEM CONTRACTOR SHALL SUBMIT ENGINEERED SIGNED AND
SEALED SHOP DRAWINGS WITH EXACT DEVICE QUANTITIES AND LAYOUTS TO AUTHORITY HAVING
JURISDICTION COMPLYING WITH STATE AND LOCAL CODES/STANDARDS.
2. DISTRIBUTED ANTENNA SYSTEM (DAS) COVERAGE SHALL MEET THE REQUIREMENTS OF NFPA 1221, INCLUDING BUT NOT LIMITED TO:
A. NFPA 1221 SECTION 9.6.7.4 - GENERAL BUILDING AREAS SHALL BE PROVIDED WITH 90 PERCENT
FLOOR AREA RADIO COVERAGE.
B. NFPA 1221 SECTION 9.6.7.3 - CRITICAL AREAS INCLUDING FIRE COMMAND CENTERS, FIRE PUMP
ROOMS, EXIT PASSAGEWAYS, ELEVATOR LOBBIES, STANDPIPE CABINETS, SPRINKLER SECTIONAL VALVE LOCATIONS, AND OTHER AREAS DEEMED CRITICAL BY THE AHJ, SHALL BE PROVIDED WITH
99 PERCENT FLOOR AREA RADIO COVERAGE.
3. SEE CONDUIT PENETRATION OF FIREWALL DETAIL ON SHEET E-501 FOR FIREWALL PENETRATION
REQUIREMENTS.
1/16" = 1'-0"EP107
2 B2 FIFTH FLOOR - POWER
0 8' 16' 32' 48'
1/16" = 1'-0"
N.T.S.EP107
1 BUILDING 2 IN-BUILDING PUBLIC SAFETY RADIO ENHANCEMENT SYSTEM
B2-5,B2-P
N
OFFICE
1006A
OFFICE
EXAM
WAITING
OFFICE
1026C
TELE
OFFICE
OFFICE
OFFICE
OFFICE
1017A
CORRIDOR
STAIRS #1
1016A
ELECT
FEC
1026B
BATHROOM
58 1030
OFFICE
1561026A
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
1058A
ELECT.
ELEV. LOB
FEC
STAIRS
BATH/SHW
OFFICE
OFFICE
OFFICE
TOILET
RESTROOM
OPTICAL SHOP
STORAGE
FEC
1111A
ELECT
TLT
OFFICE
OFFICE
TLT
TLT
TEL CL
CLOSET
KITCHEN
TOILET
STORAGE
OFFICE
P
IP
E S
P A
C E
STAIRS
OFFICE
123 1105
OFFICE
1104B
OFFICE
1104A
OFFICE
OFFICE
PIPE SPACE
PIPE SPACE
TOILET
OFFICE
STORAGE
1120A
STORAGE
GEN STORAGE
OFFICE
STORAGE
OFFICE
LOBBY
TOILET
EXAM
1008A
EXAM
TLT
TLT
OFFICE
OFFICE
TLT
1099A
OFFICE
1099B
CONFERENCE
MULTI USE
OFFICE
OFFICE
STORAGE
HAC
CANTEEN
KITCHEN
CANTEEN DINING
OPTICAL SHOP
OFFICE
OFFICE
CORR.
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
1090A
WORK AREA
ADVISOR
ADVISOR
ADVISOR
1083A
WAITING
1083B
ID CARD
SUPV
HLTH BENS
DECEDENT AF
CORRIDOR
CORRIDOR
PIPE SPACE
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
LOBBY
1006B
STOR
DAS
DAS
DAS
DAS
DAS DAS DAS DAS
DAS
DAS
DAS
DAS
DAS
DASDASDASDAS
DAS
DASDAS
EXAM
(TECH)
PRE
TEST
EXAM
EXAM
LINEN/
REPROCESSING
SOIL HOLD
PHOTO
OCT
IOL
NURSING
STAFF
2074 2077
OCT
2078 2080
EXAMEXAM
TV
7A
FA
2000F2000A
B
2001A
TESTING
2001D
CONSULT
ADMIN
2001B T R I
2001C
EXAM
ROOM
PIPE
SPACE
N..
STOR
PHOTOGRAPHY
STAIRS
#1
PIPE
SPACE
PIPE
SPACE
EXAM
EXAM
EXAM
OFFICE
2012A
CHIEFS
OFFICE
OFFICE
OFFICE
2091A
EXAM
PIPE
SPACE
STAIRS
PIPE
SPACE
LASER
OFFICE
EXAM
OPHTH. MINOR PROCEDURE
ROOM
OFFICE
OFFICE
PRE-TEST
PIPE
SPACE
EXAM
EXAM
2012B
OFFICE
2091B
EXAM
2091C
EXAM
2091D
EXAM
2091G
EXAM
2091F
EXAM
2091E
EXAM
2005A
ADMIN.
OFFICE
2005B
EXAM
2005C
EXAM
2005D
EXAM
EXAM
ROOM
2001E
OFFICE
STAIRS
#2
EXAM
EXAM
(TECH)
SUB-WAITING
MOP
VIS
FIELDS
LASER
F.
TLT
M.
TLT
LEAD
TECH
TECH
STA
SPD
CL
OFFICE
M.
TLT
TLT
EQUIP
ALCOVE
EXAM
EXAM
T R I
F.
TLT
M.
TLT
LOW-VIS
EXAM
SHARED
CONF
LOW-VIS
THERAPY
LOW-VIS
EXAM
LOW-VIS
RECEPT
TOILET
2047A
TOILET
STAFF
LOUNGE
2000D
CORR
SHARED
CONF
OPT
WAIT
RECEPTION
OPHTH
WAIT
ALCOVE
LOBBY
2000A
CORR
2000B
CORR
2000C
CORR
2000E
CORR
2000F
CORR
MECH
124 144
SPD
CL
SPD
2085A
DIAGNOSTIC
TESTING/
CATARACT
2085B
PROCEDURE
2085D
PROCEDURE
2085E P.A.
CORRIDOR
2085C
PATIENT
EDUCATION
DAS
DAS
DAS
DAS
DAS DAS DAS DAS
DAS
DAS DAS
DAS
DAS
DASDASDASDAS
DAS
DAS
DAS
2 9.7 932
DASDASDAS DAS DAS
DAS
DAS
DAS
DAS
DAS
EXISTING FIRE ALARM
ANNUNCIATOR PANEL FAAP
EXISTING FIRE ALARM
CONTROL PANEL FACP-03
TUNNEL 'G' - SEE BUILDING NO. 20
FLOOR PLAN ON SHEET EP122 AND
BUILDING NO. 2 GROUND FLOOR PLAN
ON SHEET TP102 FOR CONTINUATION
UP TO THIRD FLOOR - SEE BUILDING
NO. 3 THIRD FLOOR PLAN ON SHEET
EP109 FOR CONTINUATION
J
H N
F RAIN
E
P R
O F
ES S ION A L ENG
I N
E E
R
L I CENSE
F
LO R I D A
STATE OF
No. 90063
O
REDERICK
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Offi…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .