642-16-108 Drawings PART 03 of 06.pdf
PDF 46 MB Posted
- Solicitation number
- 36C24421B0017
About this file
This file contains details related to a federal solicitation for upgrading patient bedrooms at a Veterans Affairs medical center. Solicitation number 36C24421B0017 calls for offers to upgrade patient bedrooms in the Community Living Center Unit B at the Corporal Michael J. Crescenz Veterans Affairs Medical Center in Philadelphia, Pennsylvania. The work involves upgrading existing patient bedrooms to meet current standards and requirements as outlined in the statement of work. The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 4 is the contracting agency seeking these upgrade services. The document includes drawings to illustrate the scope of work but does not specify a response deadline or anticipated award date.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
E F R S U W
G J L P
G.3
F.3
E.7
E.4
E.2
E.1
D.9
Y BB CC
1.1
H.8HG.8
34.5
SEQUENCE C
SEQUENCE D
FOUNDATION & FIRST FLOOR PLAN
SCALE: 1/16" = 1'-0"
N O
R T
H
SS1
1. ELEVATION TOP OF THE EXISTING SLAB ON GRADE IS
46'-11 3/4".
2. THE EXISTING SLAB ON GRADE IS 5" THICK CONCRETE.
3. REPLACE SLAB AT HOLES WITH 5" MINIMUM THICK CONCRETE
REINFORCED WITH 6X6-W1.4XW1.4 WELDED WIRE FABRIC ON A
10 MIL POLYETHYLENE VAPOR BARRIER ON 6" POROUS BACKFILL.
SEQUENCE A
SEQUENCE B
EE GG
SECOND FLOOR FRAMING PLAN
SCALE: 1/16" = 1'-0"
N O
R T
H
SS1
E F R S U W
G J L P
G.3
F.3
E.7
E.4
E.2
E.1
D.9
Y BB CC
1.1
H.8HG.8
34.5
1. ELEVATION TOP OF THE EXISTING STEEL FRAMING IS 12'-9 1/2"
AS MEASURED FROM THE TOP OF THE EXISTING FIRST FLOOR
SLAB.
2. THE EXISTING SLAB IS 3 1/2" LIGHTWEIGHT CONCRETE ON
3"X20 GAGE GALVANIZED COMPOSITE METAL DECK (TOTAL SLAB
THICKNESS = 6 1/2").
3. REPLACE FLOOR AT HOLES TO MATCH EXISTING.
4. PROVIDE C4X4.5 AT EXISTING DUCT OPENINGS AS REQUIRED TO
FRAME NEW DUCT.
SEQUENCE A
SEQUENCE B
SEQUENCE C
SEQUENCE D
E X
W
X
E X
W
X
E X
W
X
E X
W
X
E X
W
X
E X
W
X
E X
W
X
E X
W
X
E X
W
X
E X
W
X
E X
W
X
E X
W
X
EX. W16X26
EX. W18X35
EX. W16X31
EX. W16X31
EX. W16X26
EX. W18X35
EX. W12X14
EX. W16X31EX. W16X31
EX. W16X31 EX. W16X31
EX. W12X14
EX. W12X14
EX. W16X31
EX. W16X31
EE GG
E X
W
X
E X
W
X
EX. W8X10
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
A
B
C
D
E
F
21 4 5 6 7 8 9
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS
321 4 5 6 7 8 9 10
Project Director
07/27/20 KR NJCRevisions: Date:
ARCHITECTURE
PLANNING
ENGINEERING
BURDETTE KOEHLER MURPHY &
ASSOCIATES, INC.
MECHANICAL / ELECTRICAL ENGINEERS
6300 BLAIR HILL LANE, SUITE 400
BALTIMORE, MARYLAND 21209
410.323.0600 - FAX 410.377.2543
BUILDING COST CONSULTANTS
COST ESTIMATING
12917 - 30TH AVENUE
PLATTSMOUTH, NEBRASKA 68048
402.298.8260 - FAX 402.298.8290
KOFFEL ASSOCIATES
FIRE PROTECTION ENGINEERS
8815 CENTRE PARK DRIVE, SUITE 200
COLUMBIA, MARYLAND 21045
410.750.2246 - FAX 410.750.2588
RICKERT ENGINEERING, INC.
STRUCTURAL ENGINEERING
8813 WALTHAM WOODS ROAD, SUITE 301
BALTIMORE, MARYLAND 21234
410.663.5110 - FAX 410.663.5114
212OfDwg.
30-SS1
STRUCTURAL
FRAMING PLANS
AutoCAD SHX Text
AutoCAD SHX Text
CORPORAL MICHAEL J. CRESCENZ VA MEDICAL CENTER PHILADELPHIA, PA
AutoCAD SHX Text
UPGRADE PATIENT BEDROOMS CLC UNIT B
AutoCAD SHX Text 642-16-108
AutoCAD SHX Text 2215 Conowingo Rd, Suite 100 Bel Air, Maryland 21015-1436 410.8`6611
E F R S U W
G J L P
G.3
F.3
E.7
E.4
E.2
E.1
D.9
Y BB CC
1.1
H.8HG.8
34.5
ROOF FRAMING PLAN
SCALE: 1/16" = 1'-0"
N O
R T
H
SS2
1. ELEVATION TOP OF THE EXISTING STEEL FRAMING AT THE LOW
ROOF IS 26'-10 1/4" AS MEASURED FROM THE TOP OF THE
EXISTING FIRST FLOOR SLAB.
2. THE EXISTING ROOF IS 2 1/4" LIGHTWEIGHT INSULATING
CONCRETE ON 2" RIGID INSULATION ON 1 1/2"X22 GAGE VENTED
METAL DECK.
3. REPLACE ROOF AT HOLES TO MATCH EXISTING.
4. PROVIDE C4X4.5 AT EXISTING DUCT OPENINGS AS REQUIRED TO
FRAME NEW DUCT.
SEQUENCE C
SEQUENCE D
E X
W
X
E X
W
X d o d o d o d o d o d o d o
EX. W16X31 EX. W16X31
EX. W16X26
E X
W
X
E X
W
X d o d o d o d o d o d o d o
EX. W16X31 EX. W16X31
EX. W16X26
EX. W16X26
EX. W16X26
do do do do do do do
SEQUENCE A
EE GG
SEQUENCE B
EX. W12X14
EX. W16X31
EX. W16X31
E X
W
X
E X
W
X
CU-2-1 WT.=
90 LBS
EX. W16X26
GENERAL NOTES
CODE
A. ALL CONSTRUCTION SHALL CONFORM TO THE PROVISIONS OF THE
INTERNATIONAL BUILDING CODE/2015.
DESIGN LIVE LOADS
A. THE MINIMUM DESIGN SUPERIMPOSED LOADS FOR ALL NEW
FRAMING IS AS FOLLOWS:
LIVE LOADS
WARD ROOMS 40 PSF
CORRIDORS IN WARDS 60 PSF
ROOF 20 PSF
ROOF SNOW LOAD
Pg 25 PSF
P 22 PSF
Ce 1.0
I 1.1
Ct 1.1
WIND
BASIC WIND SPEED (3-SEC GUST) 120 MPH
RISK CATEGORY III
EXPOSURE B
Cpi -.18 AND +.18
EARTHQUAKE
RISK CATEGORY III
SEISMIC IMPORTANCE FACTOR 1.25
SS 0.202
S1 0.060
SITE CLASS D
SDS 0.216
SD1 0.097
SEISMIC DESIGN CATEGORY B
ANALYSIS PROCEDURE - EQUIVALENT LATERAL FORCE
FOUNDATIONS
A. SELECT FILL SHALL CONFORM TO ASTM D 2487 SOIL
CLASSIFICATION GROUPS GW, GP, GM, SW, SP, AND SM; FREE
OF ROCK OR GRAVEL LARGER THAN 2 INCHES IN ANY DIMENSION,
DEBRIS, WASTE, FROZEN MATERIALS, VEGETATION AND OTHER
DELETERIOUS MATTER.
CAST IN PLACE CONCRETE
A. ALL CONCRETE WORK SHALL CONFORM TO THE PROVISIONS OF
THE "SPECIFICATION FOR STRUCTURAL CONCRETE FOR BUILDINGS"
ACI 301, AND TO THE "BUILDING CODE REQUIREMENTS FOR
STRUCTURAL CONCRETE" ACI 318.
B. NORMAL WEIGHT CONCRETE SHALL BE STONE AGGREGATE
CONCRETE HAVING A MINIMUM COMPRESSIVE STRENGTH OF
4,000 PSI AT 28 DAYS UNLESS NOTED OTHERWISE.
C. LIGHTWEIGHT CONCRETE SHALL CONTAIN AGGREGATE
CONFORMING TO ASTM A330 WITH A DRY UNIT WEIGHT OF 107 TO
116 POUNDS PER CUBIC FOOT, AIR ENTRAINMENT OF 4% TO 7%,
AND HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3,000 PSI AT
28 DAYS.
D. ALL REINFORCING BARS SHALL CONFORM TO ASTM A-615 GRADE
60. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A-185.
METAL DECK
A. METAL DECK SHALL BE FABRICATED FROM GALVANIZED STEEL
SHEET CONFORMING TO ASTM A653 G60 WITH A MINIMUM YIELD
STRENGTH OF 33 KSI.
B. THE FLOOR DECK SHALL HAVE THE FOLLOWING MINIMUM
PROPERTIES:
t=0.0358 in
I=0.993 in^4/ft
Sp=0.583 in^3/ft
Sn=0.620 in^3/ft
C. THE ROOF DECK SHALL HAVE THE FOLLOWING MINIMUM
PROPERTIES:
t=0.0295 in
I=0.17 in^4/ft
Sp=0.19 in^3/ft
Sn=0.20 in^3/ft
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
A
B
C
D
E
F
21 4 5 6 7 8 9
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS
321 4 5 6 7 8 9 10
Project Director
07/27/20 KR NJCRevisions: Date:
ARCHITECTURE
PLANNING
ENGINEERING
BURDETTE KOEHLER MURPHY &
ASSOCIATES, INC.
MECHANICAL / ELECTRICAL ENGINEERS
6300 BLAIR HILL LANE, SUITE 400
BALTIMORE, MARYLAND 21209
410.323.0600 - FAX 410.377.2543
BUILDING COST CONSULTANTS
COST ESTIMATING
12917 - 30TH AVENUE
PLATTSMOUTH, NEBRASKA 68048
402.298.8260 - FAX 402.298.8290
KOFFEL ASSOCIATES
FIRE PROTECTION ENGINEERS
8815 CENTRE PARK DRIVE, SUITE 200
COLUMBIA, MARYLAND 21045
410.750.2246 - FAX 410.750.2588
RICKERT ENGINEERING, INC.
STRUCTURAL ENGINEERING
8813 WALTHAM WOODS ROAD, SUITE 301
BALTIMORE, MARYLAND 21234
410.663.5110 - FAX 410.663.5114
212OfDwg.
30-SS2
STRUCTURAL FRAMING
PLAN AND GENERAL NOTES
AutoCAD SHX Text
AutoCAD SHX Text
CORPORAL MICHAEL J. CRESCENZ VA MEDICAL CENTER PHILADELPHIA, PA
AutoCAD SHX Text
UPGRADE PATIENT BEDROOMS CLC UNIT B
AutoCAD SHX Text 642-16-108
AutoCAD SHX Text 2215 Conowingo Rd, Suite 100 Bel Air, Maryland 21015-1436 410.8`6611
MECHANICAL LEGEND
HR
HS
FD
MOD
12x20
T
Ø
OUTSIDE AIR & EXHAUST DUCT UP
(DASHED LINES FOR DOWN)
RETURN DUCT UP
(DASHED LINES FOR DOWN)
SUPPLY AIR DUCT UP
(DASHED LINES FOR DOWN)
HEATING WATER SUPPLY
HEATING WATER RETURN
FLEXIBLE DUCT
DOUBLE THICKNESS TURNING VANES
EXISTING DUCTWORK
DUCTWORK TO BE REMOVED
DUCTWORK WITH SOUND LINING
NEW DUCTWORK
DUCT TRANSITION ROUND TO RECTANGULAR
DUCT TRANSITION
DUCT SIZE (FIRST FIGURE IS SIDE SHOWN)
LINEAR SLOT DIFFUSER
BALANCING DAMPER
MOTOR OPERATED DAMPER
FIRE DAMPER WITH ACCESS PANEL
THERMOSTAT
LIMIT OF DEMOLITION
CONNECT TO EXISTING
ABOVE FINISHED FLOOR AFF
AIR PRESSURE DROP APD
AUTOMATIC TEMPERATURE CONTROLS ATC
BUILDING AUTOMATION SYSTEM BAS
BRAKE HORSEPOWER BHP
BACKWARD INCLINED BI
BRITISH THERMAL UNIT BTU
BRITISH THERMAL UNITS PER HOUR BTUH
CUBIC FEET PER MINUTE CFM
COLD WATER (DOMESTIC) CW
DRY BULB DB
DESIGNATION DESIG
DOWN DN
DRAWING(S) DWG
EXHAUST AIR EA
ENTERING AIR TEMPERATURE EAT
ENERGY MANAGEMENT CONTROL SYSTEM EMCS
EXTERNAL STATIC PRESSURE ESP
ENTERING WATER TEMPERATURE EWT
EXISTING EX
FAN COIL UNIT FCU
FULL LOAD AMPS FLA
FINS PER INCH FPI
FEET PER MINUTE FPM
FEET FT
GALLONS PER MINUTE GPM
HORSEPOWER HP
HEATING WATER RETURN HR
HEATING WATER SUPPLY HS
HERTZ HZ
INCH(ES) IN
KILOWATT KW
LEAVING AIR TEMPERATURE LAT
POUNDS LBS
LEAVING WATER TEMPERATURE LWT
MAXIMUM MAX
THOUSAND BRITISH THERMAL UNITS PER HOUR MBH
MINIMUM CIRCUIT AMPACITY MCA
MAXIMUM FUSE SIZE MFS
MINIMUM MIN
MAXIMUM OVERCURRENT PROTECTION MOCP
POUNDS PER SQUARE INCH PSI
QUANTITY QTY
RETURN AIR RA
RELATIVE HUMIDITY RH
REVOLUTIONS PER MINUTE RPM
REMOVE EXISTING RX
SUPPLY AIR SA
TESTING AND BALANCING TAB
TOTAL STATIC PRESSURE TSP
TYPICAL TYP
VOLTS V
VARIABLE AIR VOLUME VAV
VARIABLE FREQUENCY DRIVE VFD
WET BULB WB
WATER COLUMN WC
WATER PRESSURE DROP WPD
FAN COIL UNIT FCU
MECHANICAL ABBREVIATIONS
BALANCING VALVE W/ FLOW METER
FITTING (VENTURI TYPE)
CHECK VALVE
BALL VALVE
BUTTERFLY VALVE
3-PORT MODULATING CONTROL VALVE
2-PORT MODULATING CONTROL VALVE
THERMOMETER
PIPING CAP
MANUAL AIR VENT
AUTOMATIC AIR VENT
PIPING ELBOW DOWN
PIPING ELBOW UP
PIPE CONNECTION BOTTOM
PIPE CONNECTION TOP
CO2
CO2 SENSOR
1. PRIOR TO THE START OF ANY DEMOLITION AND / OR NEW WORK, CONTRACTOR SHALL PROVIDE PRE-DEMO TAB REPORT
TO DOCUMENT EXISTING CONDITIONS OF COMPLETE EXISTING HVAC SYSTEMS ASSOCIATED WITH AC-4, ER-2, AND RTU-1.
THIS INCLUDES STATIC PROFILES FOR ALL HVAC UNIT COMPONENTS.
2. THE MECHANICAL CONTRACT DRAWINGS ARE DIAGRAMMATIC AND ARE INTENDED TO INDICATE SCOPE AND THE GENERAL
ARRANGEMENT OF THE SYSTEMS. WHERE APPLICABLE THE FOLLOWING NOTES SHALL APPLY TO ALL MECHANICAL (HVAC, PIPING AND FIRE PROTECTION) SYSTEMS.
3. THOUGH SOME DUCTWORK AND PIPING OFFSETS AND TRANSITIONS ARE INDICATED, IT IS NOT THE INTENT OF THE
DRAWINGS TO SHOW ALL OFFSETS AND TRANSITIONS REQUIRED. THE CONTRACTOR SHALL FULLY COORDINATE THE
MECHANICAL WORK WITHIN ITSELF AND WITH THE WORK OF ALL OTHER TRADES TO PROVIDE COMPLETE AND OPERABLE
SYSTEMS WITHOUT INTERFERENCES.
4. PROVIDE APPROVED FIRE STOPPING MATERIAL AROUND ALL DUCTWORK AND PIPING PENETRATIONS (NEW AND
EXISTING) THROUGH FIRE RATED FLOORS AND WALLS. REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS OF FIRE
RATED FLOORS AND WALLS. PROVIDE FIRE DAMPERS AT ALL DUCT PENETRATIONS THROUGH FLOORS AND FIRE RATED
WALLS AND FIRE/SMOKE DAMPERS AT ALL PENETRATIONS THROUGH SHAFT ENCLOSURES.
5. SUPPORT ALL EQUIPMENT (I.E. HEATERS, FANS, AIR TERMINAL UNITS, ETC.) FROM STRUCTURE WITH SPECIFIED
VIBRATION ISOLATION.
6. PROVIDE ACCESS PANELS WHERE REQUIRED FOR ADEQUATE ACCESS TO ALL CONCEALED EQUIPMENT, VALVES, DAMPERS AND CONTROLS.
7. ALL DUCT SIZES REFER TO INTERNAL FREE AREA. REFER TO DRAWINGS AND SPECIFICATIONS FOR INTERNAL INSULATION
AND SOUND LINING PRIOR TO FABRICATION.
8. ALL DUCTWORK SHALL BE CONSTRUCTED OF RIGID SHEET METAL UNLESS OTHERWISE NOTED.
9. REFER TO DOOR SCHEDULE ON ARCHITECTURAL DRAWINGS FOR UNDER CUT DIMENSIONS AND DOOR LOUVER SIZES.
10. COORDINATE DIFFUSER, REGISTER AND GRILLE LOCATIONS AND BORDER TYPES WITH ARCHITECTURAL REFLECTED
CEILING PLAN.
11. INSTALL DUCTWORK AND PIPING MAINS TIGHT TO UNDERSIDE OF STRUCTURE UNLESS OTHERWISE INDICATED.
12. REFER TO MECHANICAL DETAILS FOR TYPICAL EQUIPMENT CONNECTIONS.
13. PIPING CONNECTIONS TO HEATING AND COOLING COILS SHALL BE MADE TO PROVIDE COUNTER FLOW BETWEEN WATER
AND AIR.
14. AIR CONDITIONING (A/C) CONDENSATE PIPING SHALL BE EXTENDED FROM ALL A/C CONDENSATE SOURCE EQUIPMENT FAN
COIL UNITS, ETC.) AND CONNECTED TO THE NEAREST STORM WATER PIPE/DRAIN LOCATION. SIZE PER MANUFACTURER.
15. REFER TO STRUCTURAL DRAWINGS FOR EXACT LOCATION OF DUCT PENETRATIONS THRU ROOF. PROVIDE DUCT
TRANSITIONS AT ROOF FOR ALL ROOF MOUNTED EQUIPMENT.
16. PATCH AND SEAL ALL REMAINING OPENINGS (NEW AND EXISTING) THROUGH FLOORS, CEILINGS, WALLS, AND ROOF
RESULTING FROM DEMOLITION OR NEW WORK WITH MATERIALS AND FINISHES TO MATCH EXISTING CONSTRUCTION AND
FIRE RATING.
17. AS AN INTEGRAL PART OF THESE DOCUMENTS, THE CONTRACTOR SHALL REFER TO THE SPECIFICATIONS FOR
ADDITIONAL INFORMATION.
18. PRIOR TO THE BALANCING OF SYSTEMS BY THE AABC CERTIFIED BALANCING CONTRACTOR, ALL HIGH PRESSURE AND
LOW PRESSURE SYSTEMS SHALL BE TESTED BY THE MECHANICAL CONTRACTOR FOR DUCT LEAKAGE. DUCT LEAKAGE
SHALL NOT EXCEED 1% FOR A DURATION OF TEN (10) MINUTES. SEE SPECIFICATIONS FOR ADDITIONAL TESTING CRITERIA.
INSULATION MATERIALS SHALL NOT BE APPLIED UNTIL SYSTEMS HAVE BEEN WITNESSED, DOCUMENTED AND SUBMITTED
TO MEET THE ABOVE TESTING REQUIREMENTS. REFER SPECIFICATIONS FOR SYSTEMS INDICATED AS LOW PRESSURE OR
HIGH PRESSURE. THE BALANCE CONTRACTOR SHALL WITNESS AND CERTIFY ALL DUCT PRESSURE TESTS.
19. CONTRACTOR SHALL VISIT THE SITE AND VERIFY EXISTING CONDITIONS PRIOR TO THE BEGINNING OF ANY WORK.
FAILURE TO VISIT THE SITE SHALL IN NO WAY RELIEVE THE CONTRACTOR FROM ANY RESPONSIBILITY.
20. CONTRACTOR SHALL USE CARE WHEN PERFORMING SELECTIVE DEMOLITION. THE CONTRACTOR SHALL BE RESPONSIBLE
FOR DAMAGE TO BUILDING FINISHES, EQUIPMENT, FURNITURE, STRUCTURE, AND MECHANICAL/ELECTRICAL SYSTEMS
AND EQUIPMENT. SHOULD ANY DAMAGE OCCUR THE CONTRACTOR SHALL RESTORE DAMAGED AREA/ITEMS TO ORIGINAL
CONDITION TO MEET THE OWNER'S SATISFACTION.
21. CONTRACTOR SHALL NOTIFY AND COORDINATE WITH THE OWNER ANY UTILITY OUTAGES. OWNER SHALL BE GIVEN A
MINIMUM OF 72 HOURS NOTICE (THREE WORKING DAYS) FOR ANY OUTAGES.
22. HVAC SHALL BE MAINTAINED TO ALL AREAS OUTSIDE OF THE CURRENT PHASE OF THE RENOVATED AREA AT ALL TIMES.
PROVIDE TEMPORARY CONNECTIONS AS REQUIRED TO COORDINATE OUTAGES WITH THE OWNER A MINIMUM OF 72
HOURS (THREE WORKING DAYS) IN ADVANCE.
23. DEMOLITION AND NEW WORK THAT WILL RESULT IN DOWN TIME OF SERVICES (HVAC, PLUMBING, MEDICAL GASES, ETC.)
SHALL BE PERFORMED AT PREMIUM TIME AS REQUIRED TO MINIMIZE DOWN TIME TO ADJACENT SPACES. COORDINATE
ALL OUTAGES WITH OWNER.
24. REFER TO ARCHITECTURAL DRAWINGS FOR ADDITIONAL PHASING INFORMATION. ALL WORK AND ASSOCIATED OUTAGES
SHALL BE COORDINATED WITH THE PHASING SCHEDULE AND THE OWNER.
25. SCHEDULE ALL WORK IN OCCUPIED SPACES WITH OWNER AT LEAST TWO (2) WEEKS PRIOR TO CONSTRUCTION.
26. RETURN TO OWNER, AT THEIR DISCRETION, ALL UNUSED MECHANICAL EQUIPMENT (I.E, HEATERS, FANS, VAV BOXES, AIR
DEVICES, THERMOSTATS AND CONTROLS).
27. TAB CONTRACTOR SHALL PRE-TEST VAVS AND FAN COILS TO DOCUMENT EXISTING AIR FLOW (CFM) AND TOTAL STATIC
PRESSURE DROP PRIOR TO START OF WORK. PROVIDE DOCUMENTATION OF TEST TO THE ENGINEER AND OWNER .
28. CONTRACTOR SHALL REBALANCE EXISTING HVAC UNITS (AC-4, ER-2, AND RTU-1) VAVS AND FAN COILS TO OBTAIN AIR
QUANTITIES INDICATED. PROVIDE SHEAVE AND BELT ADJUSTMENT AND / OR REPLACEMENT AS REQUIRED. CLEAN
EXISTING FAN AND REPAIR / REPLACE EXISTING FLEXIBLE DUCT CONNECTIONS.
29. WHERE PIPING PENETRATES CONCRETE WALL AND SLABS, PROVIDE GROUND PENETRATING RADAR (GPR) SCAN TO
IDENTIFY THE LOCATION OF REBAR. SUBMIT RESULTS TO OWNER AND ENGINEER FOR REVIEW.
30. PROTECT THE ROOF FROM DAMAGE DURING THE ENTIRE CONSTRUCTION PROCESS. CONTRACTOR SHALL TAKE
PROTECTIVE MEASURES THAT ARE ACCEPTABLE TO THE ROOF MANUFACTURER TO MAINTAIN THE WARRANTY, WHERE
APPLICABLE. ALL DAMAGES AND ALTERATIONS TO THE ROOF DURING CONSTRUCTION SHALL BE REPAIRED AND
APPROVED/CERTIFIED BY THE ROOF SYSTEM MANUFACTURER.
31. ROOF PATCHING SHALL INCLUDE ALL GROUT JOINTS, INSULATION, ROOF MEMBRANES, FLASHING, AGGREGATE, ETC. TO
MATCH ROOFING MATERIALS AND MAINTAIN THE WARRANTY, WHERE APPLICABLE.
32. ALL ROOF PENETRATIONS AND ACCESSORIES (DUCTWORK, PIPING, CONDUIT, ETC.) SHALL BE INSTALLED, FLASHED AND
COUNTERFLASHED IN COMPLIANCE WITH THE CURRENT EDITIONS OF N.R.C.A. ROOFING AND WATERPROOFING MANUAL
AS WELL AS SMACNA.
33. SEE ARCHITECTURAL DOCUMENTS FOR ADDITIONAL ROOFING REQUIREMENTS.
34. WHERE PENETRATIONS OF STRUCTURAL SLAB, WALLS, ETC. ARE ANTICIPATED, PROVIDE GROUND PENETRATING RADAR
(GPR), OR OTHER APPROVED METHODS, TO DETERMINE THE LOCATION OF STRUCTURAL REINFORCEMENT. COORDINATE
ALL PENETRATIONS WITH STRUCTURAL REINFORCEMENT AS REQUIRED TO AVOID DAMAGE TO THE REINFORCEMENT AS
WELL AS TO MAINTAIN THE STRUCTURAL INTEGRITY OF ALL SLABS, WALLS, ETC. SUBMIT TO STRUCTURAL ENGINEER FOR
REVIEW.
35. CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR COORDINATION OF THE SEQUENCING OF ALL WORK ASSOCIATED WITH
PROJECT PHASES AND SEQUENCES AS IDENTIFIED ON THE ARCHITECTURAL DRAWINGS. MECHANICAL WORK MAY NOT
NECESSARILY ALIGN WITH PHASING / SEQUENCING WORK INDICATED ON THE ARCHITECTURAL DRAWINGS.
36. ATC CONTRACTOR SHALL REMOVE ALL EXISTING PNEUMATIC TUBING DURING DEMOLITION. ATC CONTRACTOR SHALL
PERMANENTLY PLUG /CAP PNEUMATIC TUBING AT EXISTING MAINS.
MECHANICAL GENERAL NOTES
CWR
CWSCHILLED WATER SUPPLY
CHILLED WATER RETURN
RSREFRIGERANT SUCTION
REFRIGERANT LIQUID RL
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
A R
L
G
D r a w i n g s A c a d B
I D o c u m e n t s M
M
H
M
E C
H A
N I C
A L
L E
G E
N
A
B B
R E
V I A
T I O
S
A
G
E N
E R
A L
N
O T
E S
P l o t t e d
B y
B r e n d o n
J
B u r l e y
P
M
BKM# 17022.01
07/27/20 212OfDwg.
BURDETTE KOEHLER MURPHY &
ASSOCIATES, INC.
MECHANICAL / ELECTRICAL ENGINEERS
6300 BLAIR HILL LANE, SUITE 400
BALTIMORE, MARYLAND 21209
410.323.0600 - FAX 410.377.2543
KOFFEL ASSOCIATES
FIRE PROTECTION ENGINEERS
8815 CENTRE PARK DRIVE, SUITE 200
COLUMBIA, MARYLAND 21045
410.750.2246 - FAX 410.750.2588
RICKERT ENGINEERING, INC.
STRUCTURAL ENGINEERING
8813 WALTHAM WOODS ROAD, SUITE 301
BALTIMORE, MARYLAND 21234
410.663.5110 - FAX 410.663.5114
BID DOCUMENTS
BUILDING COST CONSULTANTS
COST ESTIMATING
12917 - 30TH AVENUE
PLATTSMOUTH, NEBRASKA 68048
402.298.8260 - FAX 402.298.8290
30-MH1
MECHANICAL LEGEND, ABBREVIATIONS,
AND GENERAL NOTES
JDS JDT 80
UP
R X x
JHGFE
R
L P
S U W CC
Y Z
UP
UP
UP
1B134
I.T.
CLOSET
x
RX 20x10
RX 20x10 x
RX 8x6
RX 20x10 x
RX 24x12 x
RX 24x10 RX 34x14
RX 8x6
RX 8x6
RX 24x10
T
T
T
T
T
RX 22x10
RX 12x6
16x8
RX 10x4
RX 16x8
RX 12x6
RX 12x6
RX 12x6
RX 12x6
RX 12x6
RX 12x6
RX 12x6 x x x
RX 36x12 x x x x
RX 36x12
RX 10x4
RX 8x10
RX 12x6
6 6
6 6
6 6
RX 20x10
RX 34x14
RX 36x12
RX 44x24 x
RX 44x24
RX 8x6 x
RX 8x10
RX 8x10
7 7
RX 8x10
RX 8x10
RX 8x10
RX 8x10
RX 8x10
RX 8x10
RX 8x10 x
RX 36x12
12x6
RX 12x6
RX 10x10 x
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
A R
L
G
D r a w i n g s A c a d B
I o c u m e n t s M
M
H A
B
S
T
F
L
P
L
U C
T
D
P l o t t e d
B y
B r e n d o n
J
B u r l e y
P
M
BKM# 17022.01
N
Plan North Key Plan
N
True North
07/27/20 212OfDwg.
Unit C
Unit A
Court
C o u r t
(N.I.C.)
(N.I.C.)
(N.I.C.)
N
I C
Sequence B
Sequence
A
BURDETTE KOEHLER MURPHY &
ASSOCIATES, INC.
MECHANICAL / ELECTRICAL ENGINEERS
6300 BLAIR HILL LANE, SUITE 400
BALTIMORE, MARYLAND 21209
410.323.0600 - FAX 410.377.2543
KOFFEL ASSOCIATES
FIRE PROTECTION ENGINEERS
8815 CENTRE PARK DRIVE, SUITE 200
COLUMBIA, MARYLAND 21045
410.750.2246 - FAX 410.750.2588
RICKERT ENGINEERING, INC.
STRUCTURAL ENGINEERING
8813 WALTHAM WOODS ROAD, SUITE 301
BALTIMORE, MARYLAND 21234
410.663.5110 - FAX 410.663.5114
BID DOCUMENTS
Sequence
C
Sequence
D
BUILDING COST CONSULTANTS
COST ESTIMATING
12917 - 30TH AVENUE
PLATTSMOUTH, NEBRASKA 68048
402.298.8260 - FAX 402.298.8290
24'16'8'4'
SCALE: 1/8"=1'-0"
30-MH2(AB)
FIRST FLOOR PLAN
DUCTWORK - DEMOLITION
JDS JDT
DRAWING NOTES:
GENERAL NOTES:
1. REFER TO 30-MH1 FOR MECHANICAL LEGEND, ABBREVIATIONS
AND GENERAL NOTES.
2. CONTRACTOR SHALL MAKE ALL NEW TO EXISTING CONNECTIONS
FOR DUCTWORK, PIPING, AND CONTROLS TO SUPPORT
SEQUENCED CONSTRUCTION. IT IS ASSUMED THESE
CONNECTIONS WILL OCCUR AT OR NEAR THE PHASED WORK
SHOWN. HVAC SYSTEMS SERVING SEQUENCED AREAS NOT IN
CONTRACT OR DEMOLITION WHICH ARE OCCUPIED SHALL
REMAIN OPERATIONAL.
3. SYSTEMS SHUT DOWNS SHALL BE COORDINATED WITH THE
OWNER AND SHALL BE DONE WITH A 72 HOUR ADVANCED
NOTICE.
4. EACH NEW SEQUENCE IS TO BE TESTED AND BALANCED IN
ACCORDANCE WITH SPECIFICATIONS PER THE AIRFLOWS
SCHEDULED AND SHALL BE COORDINATED WITH TESTING AND
BALANCING REQUIREMENTS. AT THE COMPLETION OF THE
PROJECT TESTING AND BALANCING SHALL BE PERFORMED FOR
THE NEW AND EXISTING COMPONENTS OF THE HVAC SYSTEM.
5. REFER TO ARCHITECTURAL DIVISION FOR SEQUENCING
CONSIDERATIONS.
SCALE: 1/8" = 1'-0"
PART FIRST FLOOR - DUCTWORK - DEMOLITION
1. REMOVE EXISTING SUPPLY DUCTWORK AND ALL ASSOCIATED APPURTENANCES IN
SEQUENCE B.
2. REMOVE EXISTING EXHAUST / RETURN DUCTWORK AND ALL ASSOCIATED
APPURTENANCES IN SEQUENCE B.
3. REMOVE EXISTING AIR DEVICE AND ALL ASSOCIATED APPURTENANCES IN SEQUENCE
B.
4. REMOVE EXISTING THERMOSTAT AND ALL ASSOCIATED APPURTENANCES (TYP). ATC
CONTRACTOR SHALL REMOVE ABANDONED PNEUMATIC TUBING AND PLUG AND SEAL
AT MAIN.
5. REMOVE EXISTING RADIANT CEILING PANELS AND ALL ASSOCIATED APPURTENANCES .
6. REMOVE EXISTING SINGLE DUCT TERMINAL WITH HYDRONIC HEATING COIL IN
SEQUENCE A.
7. REMOVE EXISTING RETURN / EXHAUST DUCTWORK IN SEQUENCE A.
8. REMOVE EXISTING SUPPLY DUCTWORK IN SEQUENCE A.
9. REMOVE EXISTING AIR DEVICE IN SEQUENCE A.
10. REMOVE EXISTING RADIANT CEILING PANEL.
11. REMOVE EXISTING DUCTWORK UP TO 30-AC-4 ON FLOOR ABOVE. REFER TO 30-MH12
FOR MORE INFORMATION.
12. REMOVE EXISTING DUCT MOUNTED HEATING COIL AND ALL ASSOCIATED
APPURTENANCES.
13. EXISTING DUCTLESS SPLIT SYSTEM TO REMAIN.
SCALE: 1/8" = 1'-0"
PART FIRST FLOOR - DUCTWORK - DEMOLITION
| 055-30-AS43 |
| 056-30-AS44 |
| 057-30-AS45 |
| 058-30-AS46 |
| 059-30-AS47 |
| 060-30-AS48 |
| 061-30-AS49 |
| 062-30-AS50 |
| 063-30-AS51 |
| 064-30-AS52 |
| 065-30-AS53 |
| 066-30-AS54 |
| 067-30-AS55 |
| 068-30-AS56 |
| 069-30-AS57 |
| 070-30-AS58 |
| 071-30-AS59 |
| 072-30-AS60 |
| 073-30-AS61 |
| 074-30-AS62 |
| 075-30-AS63 |
| 076-30-AS64 |
| 077-30-AS65 |
| 078-30-SS1 |
| Sheets and Views |
| 17016 VA Phila CLC-SS1 |
| 079-30-SS2 |
| Sheets and Views |
| 17016 VA Phila CLC-SS2 |
| 080-30-MH1 MECHANICAL LEGEND ABBREVIATIONS AND GENERAL NOTES |
| Sheets and Views |
| Work |
| 081-30-MH2(AB) 1ST FLR PLN DUCT D |
| Sheets and Views |
| Work |
| 082-30-MH2(CD) 1ST FLR PLN DUCT D |
| Sheets and Views |
| Work |
| 083-30-MH3(AB) 2ND FLR PLN DUCT D |
| Sheets and Views |
| Work |
| 084-30-MH3(CD) 2ND FLR PLN DUCT D |
| Sheets and Views |
| Work |
| 085-30-MH4(AB) 1ST FLR PLN PIPING D |
| Sheets and Views |
| Work |
| 086-30-MH4(CD) 1ST FLR PLN PIPING D |
| Sheets and Views |
| Work |
| 087-30-MH5(AB) 2ND FLR PLN PIPING D |
| Sheets and Views |
| Work |
| 088-30-MH5(CD) 2ND FLR PLN PIPING D |
| Sheets and Views |
| Work |
| 089-30-MH6(AB) 1ST FLR PLN DUCT N |
| Sheets and Views |
| Work |
| 090-30-MH6(CD) 1ST FLR PLN DUCT N |
| 091-30-MH7(AB) 2ND FLR PLN DUCT N |
| 092-30-MH7(CD) 2ND FLR PLN DUCT N |
| 093-30-MH8(AB) 1ST FLR PLN PIPING N |
| 094-30-MH8(CD) 1ST FLR PLN PIPING N |
| 095-30-MH9(AB) 2ND FLR PLN PIPING N |
| 096-30-MH9(CD) 2ND FLR PLN PIPING N |
| 097-30-MH10(AB) MECHANICAL ROOF PLAN |
| 098-30-MH10(CD) MECHANICAL ROOF PLAN |
| 099-30-MH11 MECHANICAL CONTROLS |
| Sheets and Views |
| Work |
| 100-30-MH12 MECHANICAL AHU SECTIONS |
| 101-30-MH13 MECHANICAL DETAILS |
| 102-30-MH14 MECHANICAL DETAILS |
| 103-30-MH15 MECHANICAL SCHEDULES 1 |
| 104-30-MH16 MECHANICAL SCHEDULES 2 |
| 105-30-PL1 PLUMB GEN NOTES ABBREV LEGEND |
| 106-30-PL2(AB) DOMESTIC WATER 1ST FLR PLN D |
| 107-30-PL2(CD) DOMESTIC WATER 1ST FLR PLN D |
| 108-30-PL3(AB) DOMESTIC WATER 2ND FLR PLN D |
File details come from the government source that posted it. Updated .