640800_Beaufort_Co_LEC-911_New_Windows_Drawings_2024-04-30.pdf
PDF 2 MB Posted
- Attached to
- LEC Windows Installation
- Solicitation number
- 021425
- Issued by
- Beaufort County, South Carolina
About this file
These construction documents are for the Beaufort County Law Enforcement Center (LEC) 911 New Windows Project located at 2001 Duke Street in Beaufort, South Carolina. The project involves installing new windows on the second floor of the facility, with specific details including removing portions of existing EIFS cladding, installing new lintels, and replacing windows that match the existing adjacent windows' dimensions of 2'-3" x 5'-4". The project number is 640800, with design documents prepared by Moseley Architects and structural engineering by CCCS International, dated April 30, 2024.
The drawings provide comprehensive technical specifications for window replacement, including detailed demolition notes, installation requirements, and precise architectural and structural guidelines. The documents specify that all demolished materials are to be removed and disposed of off-site, existing surfaces must be prepared for new finishes, and all patches and repairs must match existing construction materials and textures. The project requires careful coordination with existing building elements, ensuring that new window installations integrate seamlessly with the current architectural style and structural integrity of the Law Enforcement Center.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AREA OF WORK
ELEVATION
R
IB
A U
T R
O A
D
DUKE STREET
AREA OF WORK
FLOOR PLAN
NN
M O
S E
L E
Y A
R C
H
IT
E C
T S
.C O
M
MOSELEYARCHITECTS.COM
THE CONTRACT DOCUMENTS ARE COMPLEMENTARY, AND WHAT IS REQUIRED BY ONE SHALL BE AS BINDING AS IF REQUIRED BY ALL.
IN CASE OF A CONFLICT, DISAGREEMENT, OR AMBIGUITY, PROVIDE THE BETTER QUALITY. IN CASE OF A CONFLICT, DISAGREEMENT, OR AMBIGUITY, PROVIDE THE GREATER QUANTITY OF WORK.
VICINITY MAP LOCATION MAP
DRAWING INDEX - VOLUME 1
PROJECT NO:
DATE:
M O
R R
IS
O
N D
R
IV
E S
U
IT
E
C
H A
R L E
S T
O N
S
C
P H
O N
E
-5
997 MORRISON DRIVE, SUITE 601 CHARLESTON, SC 29403
PHONE (843) 577-5063
4/30/2024
/1
/2
:2 :1
P
M
COVER
B E
A U
F O
R T
C O
U N
T Y
BE
AU
FO
RT
C
OU
NT
Y
LE
C-
1 N
EW
W
IN
DO
W S
PR
OJ
EC
T
D U
K E
S T
R E
E T
B E
A U
F O
R T
, S O
U T
H C
A R
O L
IN
A
P R
O
JE
C T
BEAUFORT COUNTY LEC- 911
NEW WINDOWS PROJECT
BEAUFORT COUNTY
BEAUFORT, SOUTH CAROLINA
PROJECT # 640800
CONSTRUCTION DOCUMENTS
640800
APRIL 30, 2024
G0.1
GENERAL
G0.1 COVER
ARCHITECTURAL
A2.1 FLOOR PLAN
STRUCTURAL
S100 STRUCTURAL DETAILS
CCCS International Structural Engineering
Charleston, S.C. Steve Grant (843) 452 8891
BOUNDARY STREET
C A
R T
E R
E T
S T
R E
E T
DUKE STREET
BAY STREET
SIM
MS STREET
R
IB
A U
T R
O A
D
BAY STREET
NORTH STREET
BEAUFORT RIVER
B E
A U
F O
R T
M E
M O
R
IA
L B
R
ID
G E
FRIPP
ISLAND
PRITCHARDS
ISLAND
HUNTING
ISLAND
ST HELENA ISLAND
PARRIS
ISLAND
PORT
ROYAL
LADYS
ISLAND
BEAUFORT
SITE
2001 DUKE STREET
REVISIONS
DATE DESCRIPTION
A. DEMOLITION WORK NOTED ON THESE DRAWINGS INVOLVES THE REMOVAL OF
EXISTING CONSTRUCTION UNDER THIS CONTRACT, AND SHALL BE COORDINATED
WITH CORRESPONDING RENOVATION FLOOR PLANS AND DETAILS. REMOVE
EXISTING CONSTRUCTION AS INDICATED FOR NEW WORK TO CONFORM TO
CONTRACT DRAWINGS
B. ACTUAL FIELD CONDITIONS WHICH ARE CONCEALED BY EXISTING CONSTRUCTION
MAY VARY FROM THOSE CONDITIONS INDICATED ON THE DRAWINGS. ALL WORK
THAT RELATES TO OR IS IN ANY WAY AFFECTED BY EXISTING CONDITIONS WHICH
VARY FROM THOSE INDICATED SHALL BE MODIFIED TO ACHIEVE THE INTENT OF
THE CONTRACT DOCUMENTS, ACCORDING TO FIELD ASSESSMENTS AND
MEASUREMENTS. REPORT DISCREPANCIES TO THE ARCHITECT BEFORE
PROCEEDING WITH AFFECTED ASPECTS OF DEMOLITION OR CONSTRUCTION.
C. REPRESENTATIONS OF EXISTING ITEMS REQUIRING REMOVAL ARE TO BE
CONSIDERED GENERAL IN NATURE BASED UPON INFORMATION PROVIDED IN
RECORD DRAWINGS AND FIELD OBSERVATIONS. THIS DEMOLITION PLAN AND THE
ACCOMPANYING DEMOLITION PLANS BY THE DIVISION 22 THROUGH 28 DISCIPLINES
ARE NOT INTENDED TO BE COMPREHENSIVE IN ALL DETAILS OF EXISTING
CONSTRUCTION THAT WILL HAVE TO BE REMOVED TO COMPLETE THE WORK OF
THE CONTRACT. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY
UPON NOTICE OF A BELIEVED DISCREPANCY BETWEEN THE DEMOLITION
DRAWINGS, EXISTING CONDITIONS, AND THE NEW WORK INDICATED.
D. REFER TO DIVISION 1 & 2 SPECIFICATIONS FOR ADDITIONAL INFORMATION ON
DEMOLITION WORK. COORDINATE THE DEMOLITION WORK WITH OTHER TRADES
TO PROVIDE A COMPLETE INSTALLATION OF THE NEW WORK.
E. PROTECT ALL WORK THAT IS INDICATED TO REMAIN DURING THE DEMOLITION
PROCESS. PROMPTLY REPAIR ANY DAMAGE TO PRE-DEMOLITION CONDITIONS.
F. UNLESS NOTED OTHERWISE, ALL DEMOLISHED MATERIALS ARE TO BE REMOVED
AND DISPOSED OF OFF-SITE.
G. WHERE DEMOLITION WORK EXPOSES SURFACES SCHEDULED TO RECEIVE NEW
FINISH, THE EXPOSED SURFACE SHALL BE PREPARED AS REQUIRED BY
SPECIFICATIONS AND MANUFACTURER FOR ACCEPTABLE INSTALLATION OF THE
WORK.
H. WALLS AND PARTITIONS SHOWN WITH DASHED LINES ARE TO BE REMOVED IN
THEIR ENTIRETY INCLUDING ALL DOORS, FRAMES AND ATTACHED ITEMS.
I. EXISTING CONSTRUCTION SHALL BE SHORED AND BRACED AS REQUIRED DURING
DEMOLITION AND CONSTRUCTION.
J. COORDINATE IN THE FIELD WITH THE OWNER/ARCHITECT ALL EXISTING ITEMS TO
BE SALVAGED PRIOR TO ACTUAL DEMOLITION WORK. SALVAGED ITEMS SHALL BE
SURFACE CLEANED AND STORED AS DIRECTED BY THE OWNER.
K. ALL EXPOSED SURFACES AFFECTED BY THE DEMOLITION WORK SHALL BE
PATCHED TO MATCH EXISTING ADJACENT SURFACE UNLESS SPECIFICALLY NOTED
OTHERWISE.
L. REFER TO WALL SECTIONS (AND RELATED DRAWINGS AND DETAILS) FOR
DEMOLITION REQUIREMENTS OF EXTERIOR ELEMENTS/FINISHES NOT INDICATED
ON DEMOLITION DRAWINGS.
M. ALL EXISTING INFORMATION WAS DETERMINED FROM DRAWINGS PROVIDED BY
THE OWNER AND NON-DESTRUCTIVE OBSERVATIONS. BIDDERS SHALL REVIEW
EXISTING CONDITIONS TO THE EXTENT THAT AFFECTS THE SCOPE OF DEMOLITION
AND NEW WORK.
N. PATCH, REPAIR OR FILL ALL EXISTING EXTERIOR WALLS WHERE REMOVAL OF AN
EXISTING ITEM OR SYSTEM LEAVES A VOID IN THE EXISTING WALL. VOIDS IN
EXISTING WALLS ARE TO BE PATCHED, REPAIRED, OR FILLED WITH THE SAME
CONSTRUCTION TYPE AS THE EXISTING WALL.
Q. CONTRACTOR SHALL BE RESPONSIBLE FOR PATCHING, REPAIRING AND
REPLACING ALL ITEMS OR AREAS DAMAGED/AFFECTED DUE TO DEMOLITION.
CONTRACTOR SHALL MATCH EXISTING SURROUND AND MATERIALS UNLESS
NOTED OR SPECIFIED OTHERWISE.
FLOOR PLAN GENERAL NOTES
REMOVE PORTION OF WALL AT EXISTING
RECESSES FOR NEW WINDOWS. REMOVE
PORTION OF EIFS CLADDING AS REQUIRED
FOR INSTALLATION OF NEW LINTELS.
NEW WINDOWS SHALL MATCH EXISTING
ADJACENT WINDOWS (2'-3" x 5'-4") VIF. MATCH
EXISTING HEAD HEIGHT.
REMOVE PORTION OF GWB AND
FURRING AS REQUIRED FOR
INSTALLATION OF NEW LINTELS
'-0
" ZIPWALL
ZIPWALL
A2.1
A2.1
1 1 1 1
PRIME AND PAINT PRIME AND PAINT
EXISTING SECOND
FLOOR
EIFS CLADDING AT NEW WINDOWS-PATCH
PER MFR'S RECOMMENDATION FOR SMOOTH
TRANSITION FROM NEW TO EXISTNG-MATCH
EXISTING TEXTURE. PAINT.
EXISTING SECOND
FLOOR
2'-3"
'-4
M
A T
C H
E X
IS
T
IN
G
'-6
M A
T C
H E
X
IS
T
IN
G A
S R
E Q
U
IR
E D
F O
R N
E W
L
IN
T E
L
LINTEL-REFER TO STRUCTURAL
CMU-REFER TO STRUCTURAL
METAL FURRING AS REQUIRED
5/8" GWB
METAL FURRING.
MATCH EXISTING
SEALANT AND BACKER ROD
SEALANT AND BACKER ROD
EIFS CLADDING. SEE NOTE ON
3/A2.1
1"
SLOPE FOR POSITIVE DRAINAGE
SELF ADHERING
TRANSITION MEMBRANE
DRIP EDGE FLASHING
WITH HEMMED EDGE
BREAK METAL. MATCH WINDOW
COLOR
3/4" EXTERIOR GRADE PLYWOOD
SLATE SILL-MATCH EXISTING
STOREFRONT SYSTEM.-
MATCH EXISTING
SEALANT AND BACKER ROD
EXISTING MASONRY WALL
EXISTING FURRING
EXISTING GWB
PRESSURE TREATED
BLOCKING AS REQUIRED
METAL FLASHING WITH HEMMED EDGE
BEDDED IN CONTINUOUS SEALANT
SLOPE FOR POSITIVE DRAINAGE
EIFS CLADDING. SEE NOTE ON 3/A2/1
SEALANT AND BACKER ROD
5/8" GWB
SUBSILL WITH END DAMS
BY STOREFRONT MFR.
SELF ADHERED AIR BARRIER
TRANSITION MEMBRANE
EIFS CLADDING. SEE NOTE ON 3/A2.1
EXISTING MASONRY WALL WITH GROUTED
CELLS. REFER TO STRUCTURAL
METAL FURRING-MATCH EXISTING
PRESSURE TREATED BLOCKING AS REQUIRED
5/8" GWB
SLATE SILL BEYOND-MATCH EXISTING
1'-5 7/128"
FINISH FLUSH WITH
EXISTING FINISH. PAINT
FINISH FLUSH WITH
EXISTING FINISH
AS REQUIRED FOR NEW LINTEL
MATCH EXISTING
FLUID APPLIED AIR BARRIER. EXTEND
PAST GLAZING LINE OF WINDOW
RETURN TEXTURED
FINISH TO WINDOW
SEALANT AND
BACKER ROD
M O
S E
L E
Y A
R C
H
IT
E C
T S
.C O
M
PROJECT NO:
DATE:
A
B
C
D
E
1 2 4 53 6 7 8 9 10
F
G
H
I
J
M O
R R
IS
O
N D
R
IV
E S
U
IT
E
C
H A
R L
E S
T O
N S
C
P H
O N
E
-5
/1
/2
:2 :1
P
M
FLOOR PLAN
B E
A U
F O
R T
C O
U N
T Y
BE
AU
FO
RT
C
OU
NT
Y
LE
C-
1 N
EW
W
IN
DO
W S
PR
OJ
EC
T
D U
K E
S T
R E
E T
B E
A U
F O
R T
, S O
U T
H C
A R
O L
IN
A
A2.1
P R
O
JE
C T
640800
APRIL 30, 2024
1/4" = 1'-0"A2.1 A2.1
PARTIAL SECOND FLOOR PLAN-DEMOLITION1
1/4" = 1'-0"A2.1 A2.1
PARTIAL SECOND FLOOR PLAN2
1/4" = 1'-0"A2.1 A2.1
PARTIAL ELEVATION3 WINDOW TYPE
3" = 1'-0"A2.1 A2.1
HEAD DETAIL6
3" = 1'-0"A2.1 A2.1
SILL DETAIL4
3" = 1'-0"A2.1 A2.1
JAMB DETAIL5
VERIFY SIZE OF EXISTING WINDOWS
4/30/2024
REVISIONS
DATE DESCRIPTION
1 1 1 1
A2.1
A2.1
EXISTING SECOND
FLOOR
2'-3"
5'- 4"
M
AT
CH
E
XI
ST
IN
G 1
EXISTING SECOND
FLOOR
SLATE SILL-MATCH EXISTING
STOREFRONT SYSTEM.-MATCH EXISTING
SEALNANT AND BACKER ROD
EXISTING MASONRY WALL
EXISTING FURRING
EXISTING GWB
PRESSURE TREATED BLOCKING AS REQUIRED
METAL FLASHING WITH HEMMED EDGE
SLOPE FOR POSITIVE DRAINAGE
EIFS CLADDING AT NEW WINDOWS-PATCH PER MFR'S RECOMMENDATIONFOR SMOOTH TRANSITION FROM NEWTO EXISTNG-MATCH EXISTING TEXTURE.
EXISTING EIFS CLADDING
SEALANT AND BACKER
1'-6"
EIFS CLADDING AT NEW WINDOWS-PATCH PER MFR'SRECOMMENDATION FOR SMOOTH TRANSITION FROMNEW TO EXISTNG-MATCH EXISTING TEXTURE.
EXISTING MASONRY WALL
EXISTING FURRING
EXISTING GWB
PRESSURE TREATED BLOCKING AS REQUIRED
5/8" GWB
SLATE SILL BEYOND-MATCH EXISTING
EXISTING EIFS CLADDING
A.B.GENERAL NOTE 1...GENERAL NOTE 2
FLOOR PLAN GENERAL NOTES
C D
DEMO OPENING FOR
NEW WINDOWS
DEMO OPENING FOR
NEW WINDOWS
S-100
5' - 0" 5' - 0" 1' - 2"5' - 4"
1'
1"
5'
4"
0' - 8" 2' - 0" 2' - 0" 2' - 0" 1' - 4" 0' - 8"
C8x11.5 CHANNEL AT EA FACE OF WALL
W/ 1/2"Ø THRU BOLTS @ 24" O.C. MAX.
MIN
d=8"
REMOVE BLOCK FOR WINDOW
OPENINGCOORD. DIMENSIONS
W/ ARCH
PRESSURE GROUT CELLS
BENEATH BEARING AS REQ'D
PRESSURE GROUT CELLS
BENEATH BEARING AS REQ'D
5' - 0"
REMOVE BLOCKS TO ALLOW FOR THE
INSTALLATION OF NEW LINTEL. REPLACE
BLOCK ONCE LINTEL IS INSTALLED.
1' - 2"
5'
4"
0' - 8" 2' - 0" 2' - 0" 2' - 0" 1' - 4" 0' - 8"
C8x11.5 CHANNEL AT EA FACE OF WALL
W/ 1/2"Ø THRU BOLTS @ 24" O.C. MAX.
MIN.
0' - 8"
REMOVE BLOCK FOR WINDOW
OPENINGCOORD. DIMENSIONS
W/ ARCH
PRESSURE GROUT CELLS
BENEATH BEARING AS REQ'D
PRESSURE GROUT CELLS
BENEATH BEARING AS REQ'D
5' - 0"
REMOVE BLOCKS TO ALLOW FOR THE
INSTALLATION OF NEW LINTEL. REPLACE
BLOCK ONCE LINTEL IS INSTALLED.
20' - 0"
9' - 4"
MIN
0' - 8"
WHERE EX. COLUMN IS ADJACENT TO WALL
USE 1/2"x7"x3'-6" STEEL PLATE. OVERLAP LAST
HOLE W/ CHANNEL AND SPACE HOLES IN THE
PLATE AT 1'-0" O.C.
ADD BOLT IF PLATE IS REQUIRED
SECOND FLOOR
39' - 6"
ROOF
53' - 6"
N
EW
W
IN
D O
W O
PE
N
IN
G
5'
4"
NEW PRECAST OR CMU LINTEL
W/ 1-#5 BAR CONT.
NEW INFILL CMU BLOCK
EX. BLOCK THIS LEVEL AND ABOVE
TEMPORARY C8x11.5 AT EA SIDE
W/ 1/2"Ø THRU BOLT @ 32" O.C.
(USE 1/2" STL PLATE WHERE COLUMN DOES
NOT ALLOW USE OF CHANNEL)
1' - 1"
11.
10.
9.
8.
7.
6.
5.
4.
3.
2.
C.
B.
ALL WELDING SHALL BE PERFORMED BY AWS CERTIFIED WELDERS AND IN
ACCORDANCE WITH THE AMERICAN WELDING SOCIETY STANDARD D1.1, LATEST
EDITION. USE E70 SERIES ELECTRODES.
UNLESS SHOWN OTHERWISE, PROVIDE STANDARD FRAMED OR SEATED BEAM
CONNECTIONS AS SHOWN IN PART 4 OF THE AISC"MANUAL OF STEEL CONSTRUCTION".
UNLESS GREATER REACTIONS ARE INDICATED ON THE PLANS, PROVIDE
CONNECTIONS DEVELOPING AT LEAST ONE HALF OF THE TOTAL UNIFORM LOAD
CAPACITY TABULATED IN THE TABLES OF THE AISC MANUAL FOR THE GIVEN
SECTION AND SPAN OF THE BEAM. IN NO CASE SHALL THE LENGTH OF THE
FRAMED CONNECTIONS BE LESS THAN ONE HALF THE "T" DIMENSION OF THE BEAM.
ALL DESIGN AND CONSTRUCTION OF STRUCTURAL STEEL SHALL CONFORM TO THE AISC
MANUAL OF STEEL CONSTRUCTION (NINTH EDITION).
MATERIAL:
-NO SECOND HAND MATERIAL PERMITTED
MAKE ALL FIELD MEASUREMENTS REQUIRED TO VERIFY DIMENSIONS.
CONNECTIONS:
ERECTION: PROVIDE ADEQUATE EQUIPMENT TO PERFORM THE WORK WITHOUT DAMAGE
TO PROPERTY AND PROVIDE COMPLETE SAFETY TO PUBLIC, WORKMEN AND PROPERTY.
SHOP PAINT: TOUCH UP ALL BOLTS AND WELDS WITH SHOP PAINT.
FIELD PAINT: TOUCH UP ALL BOLTS AND WELDS WITH SHOP PAINT.
CONTRACTOR SHALL SUBMIT 3 PRINTS OF ERECTION PLANS AND DETAIL SHOP
DRAWINGS FOR REVIEW BY ENGINEER BEFORE FABRICATION.
THE CONTRACTOR SHALL NOT CUT OR ALTER IN ANY WAY THE STRUCTURAL
MEMBERS WITHOUT THE APPROVAL OF THE ENGINEER.
GROUT UNDER ALL BASE PLATES AND BEARING PLATES WITH NON-SHRINK TYPE
GROUT, MINIMUM COMPRESSIVE STRENGTH OF 7000 PSI AT 28 DAYS.
STRUCTURAL STEEL SHALL RECEIVE ONE SHOP COAT OF RUST INHIBITIVE PRIMER
(SSPC PAINT 15, RED OXIDE).
1.
STRUCTURAL STEEL
A.
CHANNELS, ANGLES, & PLATE
HIGH-STRENGTH BOLT
ANCHOR ROD
THREADED ROD
A.
B.
C.
D.
ASTM A36, FY=36 KSI
ASTM A325 N
ASTM A307
ASTM A36
DESIGN BASIS: INTERNATIONAL BUILDING CODE, 2021EDITION
ASCE 7-16 MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES
ACI 318-19 MANUAL FOR CONCRETE CONSTRUCTION.
TMS 402/602-16 BUILDING CODE REQUIREMENTS AND SPECIFICATION FOR MASONRY STRUCTURES
DESIGN NOTES
10.
1.
2.
3.
4.
5.
6.
7.
8.
9.
CONCRETE
ALL REINFORCED CONCRETE WORK SHALL BE PERFORMED IN ACCORDANCE WITH
ACI 318, LATEST EDITION.
BOTH FOUNDATIONS AND SLABS SHALL HAVE A 28 DAY COMPRESSIVE STRENGTH OF
NO LESS THAN 4000 PSI.
CONCRETE IS TO BE CURED FOR A MINIMUM OF 7 DAYS BEFORE IMPOSING LOADS
FOLLOW ACI RECOMMENDATIONS FOR PLACING CONCRETE IN COLD OR HOT WEATHER.
CONTRACTOR IS TO INSURE THAT ALL CONCRETE REINFORCEMENT IS INSTALLED
PROPERLY AND PER THE PLANS BEFORE PLACING CONCRETE.
CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND FABRICATION OF ALL FORMWORK.
REBAR IS TO BE GRADE 60 PER ASTM A615
WELDED WIRE FABRIC IS TO BE PER ASTM 185.
MINIMUM COVER REQUIREMENT FOR ALL REINFORCING STEEL IS 3"
ALL FILL UNDER SLAB(S) IS TO BE COMPACTED TO 95% OF MAXIMUM DENSITY AT
OPTIMUM MOISTURE CONTENT IN ACCORDANCE WITH ASTM D1557.
CONTROL JOINTS TO BE PLACED SUCH THAT SPACING DOES NOT EXCEED 36 x SLAB
THICKNESS UP TO A MAXIMUM 18 FEET BETWEEN JOINTS PER ACI 302.
4.
3.
2.
1. VERIFY ALL DIMENSIONS AND SITE CONDITIONS PRIOR TO STARTING WORK. IF ANY
DISCREPANCIES ARE NOTED, CONTRACTOR SHALL NOTIFY ARCHITECT AND ENGINEER IMMEDIATELY.
SUBMIT SHOP DRAWINGS TO ENGINEER FOR APPROVAL. REVIEW SHOP DRAWINGS
BEFORE SUBMITTING THEM TO ENGINEER NOTING ANY DISCREPANCIES FOUND.
FAILURE TO SUBMIT THE SHOP DRAWINGS TO THE ENGINEER IS AT THE
CONTRACTOR'S OWN RISK.
STRUCTURAL DRAWINGS ARE TO BE USED IN CONJUNCTION WITH ARCHITECTURAL
AND/OR ANY OTHER TRADE RELATED DRAWINGS.
THE CONTRACTOR IS SOLELY RESPONSIBLE FOR THE DESIGN AND ERECTION OF ANY
TEMPORARY SHORING OR BRACING NECESSARY TO PROVIDE FOR THE SAFE
CONSTRUCTION OF THE STRUCTURE.
GENERAL NOTES
CONCRETE MASONRY
9.
10.
8.
6.
7.
5.
4.
3.
2.
1. ALL MASONRY WORK SHALL BE PERFORMED IN ACCORDANCE WITH ACI 530, LATEST EDITION.
PRISM STRENGTH= 1500 PSI MIN.
CMU TO COMPLY WITH ASTM C90, GRADE N, TYPE I MOISTURE CONTROLLED 8" HOLLOW UNITS.
MORTAR - USE ASTM C 270, TYPE S, CEMENT/LIME OR MASONRY CEMENT.
GROUT - ASTMC476, COARSE GROUT.
REINFORCING BARS - ASTM A615, GRADE 60
PROVIDE FULLY GROUTED BOND BEAMS W/(2) #5 BARS. SEE PLAN FOR SIZES. HORIZONTAL BARS ARE TO BE
ATTACHED TO VERTICAL REINFORCEMENT AT END OF WALLS WITH A STANDARD 180° HOOK.
PROVIDE 3/16" TRUSS TYPE, HORIZONTAL REINFORCEMENT SPACED @ 16" O.C. IN ALL MASONRY WALLS.
ALL DOWELS AT STEM WALL TO BE ATTACHED DIRECTLY TO THE HORIZONTAL STEEL IN THE FOOTING.
AT VERTICAL CONTROL JOINTS, PROVIDE ROUND SMOOTH BARS WITH ONE END GREASED TO ALLOW FOR
LATERAL MOVEMENT.
19811
SO
UTH
CAROL INA
ENG I N E E R
PRO
FESS IONAL
SEAL
S T E PH N .L GRA
NT
E
C-4561
INTERNATIONAL
CERT I F I CAT E OF AUTHO
R I Z
AT
I O N
SO
UTH
CAROL INA
CCCS
M O
SE
LE
YA
R
C H
IT
EC
TS
.C
O M
PROJECT NO:
DATE:
A
B
C
D
E
1 2 4 53 6 7 8 9 10
F
G
H
I
J
M O
R R
IS
O
N D
R
IV
E, S
U
IT
E
1, C
H
AR
LE
ST
O N
, S C
PH
O N
E (8
) 5
-5
5/ 7/
:1
2:
P M
STRUCTURAL DETAILS
BE
AU
FO
RT
C
OU
NT
Y
D
UK
E
ST
RE
ET
B
EA
UF
OR
T, SO
UT
H
CA
RO
LIN
A
S-100
E24-007 4/30/2024
3/16" = 1'-0"
3/4" = 1'-0" 3/4" = 1'-0"
REVISIONS
DATE DESCRIPTION
dbaccarini Text Box
BEAUFORT COUNTY LEC-911 NEW WINDOWS PROJECT
| Sheets |
| G0.1 - COVER |
| A2.1 - FLOOR PLAN |
File details come from the government source that posted it. Updated .