635-20-017 Modernize Elevators_100pct Drawings.pdf
PDF 12 MB Posted
- Attached to
- Z1DA--635-20-017 Renovate Elevators 1-6 Federal contract opportunity
- Solicitation number
- 36C25921R0099
About this file
This document provides details for a federal contract solicitation to renovate elevators at the Oklahoma City VA Medical Center. The contractor will modernize elevators P1 through P6, with a project magnitude between $2 million to $5 million. This is a 100% set-aside for Service-Disabled Veteran-Owned Small Businesses. Offerors must be verified and listed in the Vendor Information Pages database by the VA's Center for Verification and Evaluation. The solicitation number is 36C25921R0099 and the point of contact is listed for any questions. The work includes construction services to renovate the specified elevators, with the project to be awarded to an eligible SDVOSB.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C25921R0099 0004.docx | DOCX document | |
| Floor Heights.pdf | ||
| RFI 3.xlsx | XLSX spreadsheet | |
| 635-20-017 (VEG 20.16) Pre-bid RFI Log_Photos.pdf | ||
| 36C25921R0099 0003.docx | DOCX document | |
| Pre-Bid Site Walk.pdf | ||
| 36C25921R0099 0002.docx | DOCX document | |
| 36C25921R0099 0001.docx | DOCX document | |
| Word Specs.zip | ZIP file | |
| 36C25921R0099_1.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
N or th
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Issued:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
C :\U se rs
\V al ha lla
E ng in ee r\ D oc um en ts
\2 0.
_A
R C
H _R
_g de nt
9T P
JY
.r vt 5/
/2
:0
7:
A M
GI001
COVER SHEET MODERNIZATION OF ELEVATORS
P1 - P6
921 NE 13th ST; OKLAHOMA CITY, OK 73104
635-20-017
05/21/2021 TW DCE
100% CONSTRUCTION
DOCUMENTS
VEG 20.16
OKLAHOMA CITY VAMC
921 NE 13th ST; OKLAHOMA CITY, OK 73104
VAMC PROJECT #: 635-20-017
MODERNIZATION OF ELEVATORS P1 - P6
SHEET NUMBER SHEET NAME
GENERAL
GI001 COVER SHEET
GI002 GENERAL INFORMATION AND ABBREVIATIONS
GI003 PHASING PLAN
ARCHITECTURAL
AD111 BASEMENT - FOURTH FLOOR DEMOLITION PLANS
AD112 FIFTH - NINTH FLOOR DEMOLITION PLANS
AD113 TOP FLOORS DEMOLITION PLANS
A-111 BASEMENT - FOURTH FLOOR PLANS
A-112 FIFTH - NINTH FLOOR PLANS
A-113 TOP FLOORS PLANS
A-121 BASEMENT - FOURTH FLOOR REFLECTED CEILING PLANS
A-122 FIFTH - NINTH FLOOR & MACHINE ROOM REFLECTED CEILING
PLANS
A-220 INTERIOR ELEVATIONS
A-221 INTERIOR ELEVATIONS
A-222 INTERIOR ELEVATIONS
A-310 ELEVATOR CAB DETAILS - PASSENGER
A-311 ELEVATOR CAB DETAILS - SERVICE
A-312 ELEVATOR HALL FIXTURES
A-320 HOISTWAY SECTIONS
MECHANICAL
M-101 MECHANICAL MACHINE ROOM PLANS
ELECTRICAL
E-001 ELECTRICAL NOTES, SYMBOLS, AND LEGEND
ED101 ELECTRICAL DEMOLITION PLANS
EP101 ELECTRICAL POWER PLANS
EP102 ELECTRICAL ONE LINE DIAGRAM AND SCHEDULES
SHEET INDEXRENDERED IMAGEAREA OF WORK
100% CONSTRUCTION DOCUMENTS 05/21/2021
A. ALL CONTRACTORS AND THEIR SUPERVISORY PERSONNEL MUST REVIEW THE GENERAL AND
SUPPLEMENTARY CONDITIONS TO THE CONTRACT.
B. ALL WORK MUST CONFORM WITH APPLICABLE BUILDING CODES, REGULATIONS AND ORDINANCES.
C. CONTRACTOR MUST BECOME FULLY ACQUAINTED WITH CONDITIONS RELATED TO THE WORK.
D. CONTRACTOR MUST BE SOLELY RESPONSIBLE FOR THE MEANS, METHODS AND SEQUENCES OF
CONSTRUCTION AND THE SAFETY OF ALL CONSTRUCTION PERSONNEL AND VISITORS.
E. DRAWINGS CONTAINED IN THIS SET MUST NOT BE REPRODUCED FOR SHOP DRAWINGS. COPIES OF THESE DRAWINGS SUBMITTED AS SHOP DRAWINGS WILL BE REJECTED AND RETURNED TO THE CONTRACTOR.
F. EACH INSTALLER MUST EXAMINE SUBSTRATE AND/OR CONDITIONS UNDER WHICH THE WORK WILL BE INSTALLED AND REPORT TO THE CONTRACTOR IN WRITING ANY CONDITIONS DETRIMENTAL TO THE PROPER AND TIMELY EXECUTION OF THAT INSTALLER'S WORK. DO NOT PROCEED UNTIL UNSATISFACTORY CONDITIONS ARE CORRECTED. COMMENCING WITH INSTALLATION WILL CONSTITUTE ACCEPTANCE OF THE
SUBSTRATE AND/OR CONDITIONS.
G. DO NOT SCALE DRAWINGS: FOLLOW WRITTEN DIMENSIONS AND NOTES. CONTACT VHA COR FOR
CLARIFICATIONS, IF REQUIRED.
H. DIMENSIONS SHOWN ON THE FLOOR PLAN ARE TO THE FACE OF GYPSUM WALL BOARD (FOG), FACE OF MASONRY (FOM), FACE OF CONCRETE WALLS (FOC) AND COLUMN GRID LINES, UNLESS OTHERWISE NOTED
OR INDICATED OTHERWISE.
I. "TYPICAL", AS USED IN THESE DOCUMENTS, MEANS THAT THE CONDITION OR DIMENSION IS
REPRESENTATIVE OF, OR THE SAME, FOR SIMILAR CONDITIONS THROUGHOUT.
J. IF THERE ARE ANY DISCREPANCIES BETWEEN THE DRAWINGS AND SPECIFICATIONS, CONTACT VHA COR FOR CLARIFICATION. FOR BIDDING PURPOSES: THE MOST EXPENSIVE AND/OR STRICTEST REQUIREMENTS MUST GOVERN. FOR CLARIFICATIONS DURING CONSTRUCTION: THE MOST EXPENSIVE AND/OR STRICTEST
REQUIREMENTS, AS INDICATED BY THE VHA COR, MUST GOVERN.
K. ANY DISCREPANCIES BETWEEN THE DRAWINGS AND ACTUAL CONDITIONS MUST BE REPORTED TO THE VHA
COR IN WRITING FOR RESOLUTION, PRIOR TO PROCEEDING WITH THE WORK.
L. ANY AND ALL DISCREPANCIES MUST BE REPORTED TO THE VHA COR IN WRITING FOR RESOLUTION, PRIOR TO PROCEEDING WITH THE WORK. IN THESE INSTANCES, NO CHANGE ORDERS OR EXTENSIONS OF TIME WILL BE ALLOWED OR ACCEPTED FOR PROCEEDING WITH THE WORK WITHOUT THE VHA COR'S WRITTEN DIRECTION AND APPROVAL. ALSO, CONTRACTOR MUST REPAIR AND/OR REPLACE ANY UNAUTHORIZED WORK, AS
INDICATED BY THE VHA COR, AT NO ADDITIONAL COST TO THE OWNER.
M. ALL DISSIMILAR METAL MATERIALS MUST BE ISOLATED WITH AN APPROVED NONMETAL ISOLATION MATERIAL.
N. ALL EXTERIOR EXPOSED STEEL MUST BE PAINTED.
O. OPEN EXTERIOR JOINTS AROUND WINDOW AND DOOR FRAMES, BETWEEN WALLS AND FOUNDATIONS, BETWEEN WALL PANELS AND AT PENETRATIONS OF UTILITIES THROUGH THE BUILDING ENVELOPE, ETC, MUST BE SEALED, CAULKED, FLASHED OR WEATHER-STRIPPED AS REQUIRED FOR COMPATIBILITY WITH
ADJACENT MATERIALS AND TO ELIMINATE AIR LEAKAGE AND WATER ENTRY.
P. CONTRACTOR MUST COORDINATE SIZE, LOCATIONS AND NUMBER OF ALL ROOF OPENINGS AND ROOF ACCESSORIES WITH ALL OTHER TRADES. REFER TO THE ARCHITECTURAL, STRUCTURAL, PLUMBING, MECHANICAL AND ELECTRICAL DRAWINGS.
Q. LOCATIONS AND SIZES OF ALL CONCRETE MECHANICAL AND ELECTRICAL PADS MUST BE COORDINATED BY THE MECHANICAL AND ELECTRICAL CONTRACTORS WITH THE SELECTED EQUIPMENT MANUFACTURER AND/OR SUPPLIER. LOCATIONS AND ARE TO BE APPROVED BY THE VHA COR PRIOR TO PROCEEDING WITH
THE WORK.
R. EXCEPT AT FIRE-RATED PARTITIONS, ALL WALL AND COLUMN GYPSUM BOARD FACING MUST BE HELD AT 5/8"
BELOW STRUCTURE, UNLESS DETAILED OR NOTED OTHERWISE.
S. AT ALL TELECOMMUNICATION ROOMS: PROVIDE 3/4" X 8'-0" HIGH FIRE-RETARDANT-TREATED WOOD SHEATHING OR PROVIDE PLYWOOD OVER NON-COMBUSTIBLE SHEATHING, BOTTOM TO BE LOCATED AT 4"
AFF VERIFY LENGTHS AND LOCATIONS WITH ELECTRICAL DRAWINGS.
T. ALL CEILING HEIGHTS AS SHOWN ON PLANS AND DETAILS ARE FROM SLAB OR TILE FLOOR (FINISHED FLOOR)
TO FINISH CEILING.
U. PROVIDE INDEPENDENT FRAMING AND ATTACHMENTS TO THE STRUCTURE, ADEQUATE TO SUPPORT THE CEILING SYSTEM, LIGHT FIXTURES, DUCTS, DIFFUSERS, SPRINKLER PIPING AND BUS DUCTS.
V. ALL CLOSETS AND ALCOVES WITHOUT A SPACE IDENTIFICATION NUMBER MUST HAVE THE SAME FINISHES AS
ADJOINING SPACES.
W. ALL PROPRIETARY PRODUCTS DESCRIBED AND/OR DRAWN IN THE DOCUMENTS (BUT NOT SPECIFIED) ARE TO
MEET THE MANUFACTURER'S STANDARD CRITERIA WHICH IS NOT LIMITED TO THE FOLLOWING:
PERFORMANCE REQUIREMENTS, QUALITY ASSURANCE REQUIREMENTS, APPLICABLE CODES AND INDUSTRY STANDARDS, FABRICATION, ASSEMBLY, HANDLING, DELIVERY, STORAGE, INSTALLATION, OPERATION, ADJUSTMENTS, ETC. PROVIDE THE MANUFACTURER'S STANDARD WARRANTY AND STANDARD FINISH WARRANTY. PROVIDE PRODUCT DATA, SHOP DRAWINGS, SAMPLES AND MAINTENANCE DATA, AS REQUIRED.
REFER TO DIVISION 01 SPECIFICATION SECTIONS WHICH ALSO APPLY, SUCH AS SUBSTITUTION PROCEDURES, SUBMITTAL PROCEDURES, QUALITY REQUIREMENTS, REFERENCES, EXECUTION AND CLOSEOUT PROCEDURES. ANY SUBSTITUTIONS MUST MEET THE DESIGN INTENT, AS WELL AS THE CRITERIA
DESCRIBED ABOVE.
X. REFER TO SPECIFICATIONS FOR ALL REQUIRED TESTING AND INSPECTIONS.
Y. ADOPTED VHA CODES AND STANDARDS (FOR REFERENCE ONLY)
• VA DIRECTIVES, DESIGN MANUALS, MASTER SPECIFICATIONS, VA NATIONAL CAD STANDARD APPLICATION
GUIDE, AND OTHER GUIDANCE ON THE TECHNICAL INFORMATION LIBRARY (TIL)
• NFPA 101 LIFE SAFETY CODE - 2018 (LSC)
• NFPA 70 NATIONAL ELECTRICAL CODE - 2020 (NEC)
• NFPA NATIONAL FIRE CODES (EXCEPTIONS : NFPA 5000 AND NFPA 900)
• INTERNATIONAL BUILDING CODE - 2018 (IBC)
• INTERNATIONAL PLUMBING CODE - 2018 (IPC)
• OCCUPATIONAL, SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARDS
• VA SEISMIC DESIGN REQUIREMENTS, H-18-8
• SAFETY CODE FOR ELEVATORS AND ESCALATORS, AMERICAN SOCIETY OF MECHANICAL ENGINEERS
(ASME) A17.1 - CURRENT EDITION
• ASME BOILER AND PRESSURE VESSEL CODE
• ASME CODE FOR PRESSURE PIPING
• ARCHITECTURAL BARRIERS ACT ACCESSIBILITY STANDARDS (ABAAS) INCLUDING VA SUPPLEMENT, BARRIER FREE DESIGN GUIDE (PG-18-13)
• BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE, AMERICAN CONCRETE INSTITUTE AND
COMMENTARY (ACI 318)
• MANUAL OF STEEL CONSTRUCTION, LOAD AND RESISTANCE FACTOR DESIGN SPECIFICATIONS FOR
STRUCTURAL STEEL BUILDINGS, AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC)
GENERAL NOTES
CEILING HEIGHT
SUPPLY
RETURN / EXHAUST
TYPICAL LIGHT FIXTURE
SIZE VARIES
9'-0"
REFLECTED CEILING PLAN SYMBOLS LEGEND
OS
LINEAR PENDANT LIGHT
INDUSTRIAL STRIP LIGHT
CAN LIGHTACCESS PANEL
OCCUPANCY SENSOR
FIRE EXIT SIGN
SPRINKLER HEAD
ROOM NAME
A3
SECTION, DETAIL, OR ELEVATION TITLE EXAMPLE
ELEVATION CALLOUT EXAMPLE
DETAIL CALLOUT EXAMPLE
SECTION CALLOUT EXAMPLE
SECTION, DETAIL, OR ELEVATION SYMBOL
IDENTIFIERS
DETAIL NAME
LETTER OR NUMBER
DESIGNATOR
DRAWING
SEQUENCE NUMBER
INDICATES WHERE
TITLE IS LOCATED
DISCIPLINE DESIGNATOR (MAY
NOT BE PRESENT IF CALLOUT
AND TITLE ARE ON DRAWINGS
WITHIN THE SAME DISCIPLINE)
AE101
DOOR
NUMBER TAG
WALL
TYPE TAG
WINDOW
TYPE TAG
CENTER LINE
COLUMN
BUBBLE
ROOM TAG
MATCH LINE
DETAIL NUMBER
ON SHEET
SHEET NUMBER
DETAIL NUMBER
ON SHEET
SHEET NUMBER
NEW LINE TYPE
EXISTING LINE TYPE
DEMO LINE TYPE
DEMO HATCH TYPE
1 HOUR FIRE RESISTANCE RATED LINE
1 HOUR FIRE RATED,
SMOKE BARRIER LINE
2 HOUR FIRE RATED,
SMOKE BARRIER LINE
3 HOUR FIRE RATED,
SMOKE BARRIER LINE
4 HOUR FIRE RATED,
SMOKE BARRIER LINE
VIEW NAME
1/8" = 1'-0"
2 HOUR FIRE RESISTANCE RATED LINE
3 HOUR FIRE RESISTANCE RATED LINE
4 HOUR FIRE RESISTANCE RATED LINE
AE101
AE101
A
AS101
FLOOR PLAN SYMBOLS LEGEND
S
S
S
S
AE10
EXTERIOR
INTERIOR
XX KEYNOTE
REVISION TAG
DRAWING SCALE
MATERIAL
KEYNOTE
FIXTURE
KEYNOTE
DETAIL NUMBER
ON SHEET
SHEET NUMBER
W3
XX.YYA
XX.YYA
A
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Issued:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
C :\U se rs
\V al ha lla
E ng in ee r\ D oc um en ts
\2 0.
_A
R C
H _R
_g de nt
9T P
JY
.r vt 5/
/2
:0
7:
A M
GI002
GENERAL INFORMATION AND
ABBREVIATIONS
MODERNIZATION OF ELEVATORS
P1 - P6
921 NE 13th ST; OKLAHOMA CITY, OK 73104
635-20-017
NA
05/21/2021 TW DCE
100% CONSTRUCTION
DOCUMENTS
VEG 20.16
SECT SECTION
SF SQUARE FOOT (SQFT)
SHT SHEET
SIM SIMILAR
SOG SLAB ON GRADE
SPEC SPECIFICATION (S)
SPKLR SPRINKLE
SPKR SPEAKER
SQ SQUARE
SS STAINLESS STEEL
STC SOUND TRANSMISSION COEFFICIENT
STD STANDARD
STL STEEL
STOR STORAGE
STRUCT STRUCTURE / STRUCTURAL
SUSP SUSPENDED
SY SQUARE YARD (SQ YD)
SYM SYMMETRICAL / SYMBOL
SYS SYSTEM
T
T TREAD
TEL TELEPHONE
TEMP TEMPORARY / TEMPERED
TG TONGUE & GROOVE
THK THICK (NESS)
THRU THROUGH
TKBD TACK BOARD
TO TOP OF
TOC TOP OF CURB / CONCRETE
TOD TOP OF DECK
TOM TOP OF MASONRY
TOP TOP OF PARAPET
TOR TOP OF ROOF
TOS TOP OF STEEL
TOW TOP OF WALL
TPO THERMOPLASTIC POLYOLEFIN
TRANSF TRANSFORMER
TV TELEVISION
TYP TYPICAL
TZ TERRAZZO
U
UH UNIT HEATER
UNFIN UNFINISHED
UNO UNLESS NOTED OTHERWISE
V
VB VAPOR BARRIER (VPR BR)
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VEST VESTIBULE
VHA VETERANS HEALTH ADMINISTRATION
VIF VERIFY IN FIELD
VNR VENEER
VTR VENT THROUGH ROOF
VWC VINYL WALLCOVERING
W
W WEST, WIDTH, WIDE
W/ WITH
W/IN WITHIN
W/O WITHOUT
WB WOOD BASE
WC WATER CLOSET
WD WOOD
WDW WINDOW
WH WALL HYDRANT / WATER HEATER
WP WATERPROOFING / WORKING POINT
WR WEATHER RESISTANT
WSF WELDED SEAM SHEET FLOORING
WT WEIGHT
WWF WELDED WIRE FABRIC
X, Y, Z, MISC
& AND
@ AT
XPS EXTRUDED POLYSTYRENE
YD YARD
N
N NORTH
NA NOT APPLICABLE
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NRC NOISE REDUCTION COEFFICIENT
NSF NET SQUARE FEET
NTS NOT TO SCALE
O
OA OVERALL
OC ON CENTER
OD OUTSIDE DIAMETER
OH OVERHEAD / OPPOSITE HAND
OPNG OPENING
OPP OPPOSITE
OPR OPERABLE
ORD OVERFLOW ROOF DRAIN
OZ OUNCE
P
PA PUBLIC ADDRESS
PB PUSH BUTTON
PC PRECAST CONCRETE
PCF POUNDS PER CUBIC FOOT
PERF PERFORATE (D)
PERM PERMANENT
PERP PERPENDICULAR
PL PLATE / PROPERTY LINE
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLUMB PLUMBING
PLYWD PLYWOOD
PNL PANEL
POLY POLYETHYLENE
PR PAIR
PREFAB PREFABRICATE (D)
PREFIN PREFINISHED
PRELIM PRELIMINARY
PREP PREPARE (D)
PROJ PROJECT
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PAINT / PORCELAIN TILE
PTN PARTITION
PVC POLYVINYL CHLORIDE
PVG PAVING
Q
QT QUARRY TILE
QTB QUARRY TILE BASE
QTY QUANTITY
R
R RISER / RADIUS
RA RETURN AIR
RB RESILIENT BASE
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
REF REFRIGERATOR
REINF REINFORCE (D), (ING)
REQD REQUIRED
REV REVISED/ REVISION
RFG ROOFING
RH RIGHT HAND
RM ROOM
RO ROUGH OPENING
ROW RIGHT OF WAY
RR RESTROOM
RSF RESILIENT SHEET FLOORING
RTU ROOF TOP UNIT
S
S SOUTH
SAN SANITARY SEWER
SC SOLID CORE
SCH SCHEDULE
SCRN SCREEN
H
H HIGH
HB HOSE BIBB
HC HOLLOW CORE
HD HEAD
HDBD HARDBOARD
HDR HEADER
HDW HARDWARE
HDWD HARDWOOD
HK HOOK
HM HOLLOW METAL
HORIZ HORIZONTAL
HR HOUR
HS HIGH STRENGTH
HT HEIGHT
HTG HEATING
HTR HEATER
HVAC HEATING / VENTILATING / AIR CONDITIONING
HW HOT WATER
HWH HOT WATER HEATER
HYD HYDRANT
I
IBC INTERNATIONAL BUILDING CODE
ICRA INFECTION CONTROL RISK ASSESSMENT
ID INSIDE DIAMETER
ILSM INTERIM LIFE SAFETY MEASURES
IN INCH
INCL INCLUDE (D), (ING)
INFO INFORMATION
INST INSTALL / INSTALLATION
INSUL INSULATE / INSULATION
INT INTERIOR
INV INVERT
J
JAN JANITOR
JB JUNCTION BOX
JST JOIST
JT JOINT
K
KIT KITCHEN
KO KNOCKOUT
KPL KICK PLATE
L
L LONG / LENGTH
LAB LABORATORY
LAM LAMINATE (D)
LAV LAVATORY
LBS POUNDS
LF LINEAR FOOT (FEET)
LH LEFT HAND
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LPT LOW POINT
LRG LARGE
LT LIGHT
LTG LIGHTING
LVR LOUVER
LVT LUXURY VINYL TILE
LWC LIGHTWEIGHT CONCRETE
M
MAS MASONRY
MAX MAXIMUM
MBR MEMBER
MDF MEDIUM DENSITY FIBERBOARD
MECH MECHANICAL
MED MEDIUM
MEMB MEMBRANE
MFG MANUFACTURING
MFR MANUFACTURER
MH MANHOLE
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
MOD MODULAR
MTD MOUNTED
MTG MOUNTING
MTL METAL
MULL MULLION
DH DOUBLE HUNG
DIA DIAMETER
DIAG DIAGONAL
DIM DIMENSION
DISP DISPENSER
DMT DEMOUNTABLE
DN DOWN
DR DOOR
DS DOWNSPOUT
DTL DETAIL
DWG DRAWING
E
E EAST
EA EACH
EF EXHAUST FAN
EJ EXPANSION JOINT
EL ELEVATION
ELAST ELASTOMERIC
ELEC ELECTRICAL
ELEV ELEVATOR
EM EMERGENCY
EP ELECTRICAL PANELBOARD
EQ EQUAL
EQUIP EQUIPMENT
ESC ESCALATOR
EST ESTIMATE
ETR EXISTING TO REMAIN
EW EACH WAY
EWC ELECTRIC WATER COOLER
EXH EXHAUST
EXIST EXISTING
EXP EXPANSION / EXPOSED
EXT EXTERIOR
F
FA FIRE ALARM
FAB FABRIC
FB FACE BRICK
FBO FURNISHED BY OWNER
FD FLOOR DRAIN
FDC FIRE DEPARTMENT CONNECTION
FDN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF FINISH FLOOR
FF&E FIXTURES, FURNITURE & EQUIPMENT
FFE FINISH FLOOR ELEVATION
FH FIRE HYDRANT
FHC FIRE HOSE CABINET
FIN FINISH / FINISHED
FIXT FIXTURE
FLG FLOORING
FLR FLOOR
FLUOR FLUORESCENT
FOC FACE OF CONCRETE
FOF FACE OF FINISH
FOG FACE OF GYPSUM BOARD / WALL
FOM FACE OF MASONRY
FOS FACE OF STUDS
FR FIRE RATED
FRMG FRAMING
FRP FIBER REINFORCED PANEL
FS FLOOR SINK
FT FOOT/ FEET
FTG FOOTING
FUR FURRING
FUT FUTURE
G
GA GAUGE
GALV GALVANIZED
GB GRAB BAR
GC GENERAL CONTRACTOR
GFRC GLASS FIBER REINFORCED CONCRETE
GL GLASS / GLAZING
GOVT GOVERNMENT
GPM GALLON PER MINUTE
GSF GROSS SQUARE FEET
GWB GYPSUM WALL BOARD
GYP GYPSUM
A
ABA ARCHITECTURAL BARRIERS ACT
AC AIR CONDITIONING
ACP ACOUSTICAL CEILING PANEL
ACST ACOUSTICAL
ACT ACOUSTICAL CEILING TILE
AD AREA DRAIN
ADJ ADJUSTABLE / ADJACENT
AFF ABOVE FINISH FLOOR
AHU AIR HANDLING UNIT
ALT ALTERNATE
ALUM ALUMINUM
ANOD ANODIZED
AP ACCESS PANEL
APC ARCH PRECAST CONCRETE
APPROX APPROXIMATE
ARCH ARCHITECT / ARCHITECTURAL
ATTEN ATTENUATION
AUTO AUTOMATIC
AV AUDIO / VISUAL
AVG AVERAGE
AWP ACOUSTICAL WALL PANEL
B
BD BOARD
BITUM BITUMINOUS
BLDG BUILDING
BLKG BLOCKING
BM BENCH MARK / BEAM
BO BOTTOM OF
BOC BACK OF CURB
BOT BOTTOM
BRG BEARING
BRK BRICK
BRKT BRACKET
BSMT BASEMENT
BTWN BETWEEN
BVL BEVELED
C
C COURSE
CAB CABINET
CAP CAPACITY
CB CATCH BASIN
CCTV CLOSED CIRCUIT TV
CF CUBIC FEET
CFM CUBIC FEET PER MINUTE
CG CORNER GUARD
CI CAST IRON
CIP CAST-IN-PLACE
CJ CONTROL JOINT
CL CENTER LINE
CLG CEILING
CLOS CLOSET
CLR CLEAR / CLEARANCE
CMP CORRUGATED METAL PIPE
CMT CERAMIC MOSAIC TILE
CMU CONCRETE MASONRY UNIT
CO CLEAN OUT
COL COLUMN
COMB COMBINATION
CONC CONCRETE
CONN CONNECTION / CONNECT
CONST CONSTRUCT / CONSTRUCTION
CONT CONTINUOUS
CONTR CONTRACTOR
COORD COORDINATE
COR CONTRACTING OFFICER'S REPRESENTATIVE
CORR CORRIDOR / CORRUGATED
CP CONCRETE PIPE
CPT CARPET
CS COUNTERSINK
CSMT CASEMENT
CT CERAMIC TILE
CU CUBIC
CW COLD WATER
D
DBL DOUBLE
DEMO DEMOLISH / DEMOLITION
DEPT DEPARTMENT
DF DRINKING FOUNTAIN
ARCHITECTURAL ABBREVIATIONS
A. ICRA BARRIER LOCATIONS, PER SPEC SECTION 01 35 26, SAFETY
REQUIREMENTS, MAY BE ADJUSTED FROM RECOMMENDATION ON PLANS;
MINIMUM DEFINED CLEARANCES MUST BE MAINTAINED (72"). ICRA BARRIER
MUST OBSTRUCT MORE THAN HALF OF THE CORRIDOR WIDTH.
B. CONSTRUCTION BARRIER ENTRIES, PER SPEC SECTION 01 35 26, SAFETY
REQUIREMENTS, SHALL BE SECURED AT ALL TIMES.
C. INSTALL TEMPORARY BARRIERS, PER SPEC SECTION 01 35 26, SAFETY
REQUIREMENTS, WITHOUT DAMAGING EXISTING FINISHES.
D. PHASING IS SHOWN AT THE BASEMENT; CONSTRUCT ICRA BARRIERS IN
SIMILAR LOCATIONS ON UPPER FLOORS; MODIFY AS REQUIRED.
JKL
ELEV P2
ELEV P3
ELEV P4
ELEV P5
ELEV P6
ELEV P1
ICRA BARRIER
ICRA BARRIER
MIN CLR
6' - 0"
JKL
ELEV P2
ELEV P3
ELEV P4
ELEV P5
ELEV P6
ELEV P1
ICRA BARRIER
MIN CLR
6' - 0"
JKL
ELEV P2
ELEV P3
ELEV P4
ELEV P5
ELEV P6
ELEV P1
ICRA BARRIER
MIN CLR
6' - 0"
JKL
ELEV P2
ELEV P3
ELEV P4
ELEV P5
ELEV P6
ELEV P1
ICRA BARRIER
MIN CLR
6' - 0"
JKL
ELEV P2
ELEV P3
ELEV P4
ELEV P5
ELEV P6
ELEV P1
ICRA BARRIER
MIN CLR
6' - 0"
JKL
ELEV P2
ELEV P3
ELEV P4
ELEV P5
ELEV P6
ELEV P1
ICRA BARRIER
N or th
E
A
B
F
D
G
HW
C
5 18
KEY PLAN
GENERAL NOTES
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Issued:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
C :\U se rs
\V al ha lla
E ng in ee r\ D oc um en ts
\2 0.
_A
R C
H _R
_g de nt
9T P
JY
.r vt 5/
/2
:0
7:
A M
GI003
PHASING PLAN MODERNIZATION OF ELEVATORS
P1 - P6
921 NE 13th ST; OKLAHOMA CITY, OK 73104
635-20-017
05/21/2021 TW GD
100% CONSTRUCTION
DOCUMENTS
VEG 20.16
32'16'8'4'2'0'
N or th
1/8" = 1'-0"
BASEMENT - PHASE 1
32'16'8'4'2'0'
N or th
1/8" = 1'-0"
BASEMENT - PHASE 3
32'16'8'4'2'0'
N or th
1/8" = 1'-0"
BASEMENT - PHASE 6
32'16'8'4'2'0'
N or th
1/8" = 1'-0"
BASEMENT - PHASE 5
32'16'8'4'2'0'
N or th
1/8" = 1'-0"
BASEMENT - PHASE 4
32'16'8'4'2'0'
N or th
1/8" = 1'-0"
BASEMENT - PHASE 2
PHASE 1 : MODERNIZE ELEVATOR P5
• USE ELEVATOR P5 AND 9TH FLOOR SERVICE LOBBY CEILING HATCH
TO BRING NEW EQUIPMENT TO THE MACHINE ROOM.
• MAINTAIN STAFF ACCESS THROUGH SERVICE LOBBY ON FLOORS G,
4, 6, 7, AND 9.
• INSTALL REQUIRED EQUIPMENT TO RETURN THE PASSENGER
LOBBY SIDE DOOR TO OPERATION.
• INSTALL INCONSPICUOUS RISER AS SHOWN ON DRAWINGS.
• PROGRAM CAR TO FUNCTION AS SIMPLEX OR GROUP OPERATION.
• INSTALL TEMPORARY CROSS-CALL REGISTRATION/CANCELLATION
OVERLAY.
PHASE 3 : MODERNIZE ELEVATOR P3
• RETURN ELEVATOR P5 TO GROUP OPERATION.
• USE ELEVATOR P5 TO BRING EQUIPMENT TO THE 9TH FLOOR AND
THE MAIN LOBBY CEILING HATCH TO GET NEW EQUIPMENT INTO THE
MACHINE ROOM. (AFTER NORMAL BUSINESS HOURS)
• REPLACE THE SOUTH HALL CALL BUTTONS (BETWEEN P3 AND P4)
AS PART OF THIS PHASE; PROVIDE TEMPORARY HALL CALL BUTTON
FOR VISITOR USE OF ELEVATORS P4 AND P5.
PHASE 6 : MODERNIZE ELEVATOR P1
• USE ELEVATOR P5 TO BRING EQUIPMENT TO THE 9TH FLOOR AND
THE MAIN LOBBY CEILING HATCH TO GET NEW EQUIPMENT INTO THE
MACHINE ROOM. (AFTER NORMAL BUSINESS HOURS)
• MAINTAIN STAFF ACCESS THROUGH MAIN LOBBY ON FLOOR 8.
• REPLACE THE NORTH HALL CALL BUTTONS (BETWEEN P1 AND P2)
AS PART OF THIS PHASE.
• REPLACE EXISTING GROUP DISPATCHER AND REMOVE TEMPORARY
CROSS-CALL REGISTRATION/CANCELLATION OVERLAY.
PHASE 2 : MODERNIZE ELEVATOR P6
• SET ELEVATOR P5 TO FUNCTION AS SIMPLEX.
• USE ELEVATOR P5 AND 9TH FLOOR SERVICE LOBBY CEILING HATCH TO BRING
NEW EQUIPMENT TO THE MACHINE ROOM.
• MAINTAIN STAFF ACCESS THROUGH SERVICE LOBBY ON FLOORS G, 4, 6, 7, AND 9.
• PROVIDE TEMPORARY HALL CALL BUTTON FOR STAFF USE OF ELEVATOR P5 AND
REPLACE THE HALL CALL BUTTONS IN THIS PHASE.
• REPAIR DAMAGED LOBBY FINISHES AND INSTALL NEW LOBBY FINISHES (AT
SERVICE LOBBY) PER SCHEDULE, TYP.
PHASE 4 : MODERNIZE ELEVATOR P4
• USE ELEVATOR P5 TO BRING EQUIPMENT TO THE 9TH FLOOR AND
THE MAIN LOBBY CEILING HATCH TO GET NEW EQUIPMENT INTO THE
MACHINE ROOM. (AFTER NORMAL BUSINESS HOURS)
• REPAIR DAMAGED LOBBY FINISHES AND INSTALL NEW LOBBY
FINISHES PER SCHEDULE, TYP.
• PROVIDE TEMPORARY HALL CALL BUTTON FOR VISITOR USE OF
ELEVATOR P5.
PHASE 5 : MODERNIZE ELEVATOR P2
• USE ELEVATOR P5 TO BRING EQUIPMENT TO THE 9TH FLOOR AND
THE MAIN LOBBY CEILING HATCH TO GET NEW EQUIPMENT INTO THE
MACHINE ROOM. (AFTER NORMAL BUSINESS HOURS)
• MAINTAIN STAFF ACCESS THROUGH MAIN LOBBY ON FLOOR 8.
• PROVIDE TEMPORARY HALL CALL BUTTON FOR VISITOR USE OF
ELEVATOR P1.
A. REFER TO SHEET GI003 FOR PHASING AND PROPOSED CONSTRUCTION
BARRIER LOCATIONS.
JKL
1 3
ELEV P2
ELEV P3
ELEV P4
ELEV P5
ELEV P6
ELEV P1
1 3
1 3
1 3
1 3
1 3
B-100A
MAIN
LOBBY
B-100B
SERV.
LOBBY
JKL
1 3
1 3
1 3
1 3
1 3
1 3
ELEV P2
ELEV P3
ELEV P4
ELEV P5
ELEV P6
ELEV P1
G-100A
MAIN
LOBBY
G-100B
SERV.
LOBBY
JKL
1 3
1 3
1 3
1 3
1 3
1 3
ELEV P2
ELEV P3
ELEV P4
ELEV P5
ELEV P6
ELEV P1
01-100A
MAIN
LOBBY
01-100B
SERV.
LOBBY
JKL
1 3
1 3
1 3
1 3
1 3
1 3
ELEV P2
ELEV P3
ELEV P4
ELEV P5
ELEV P6
ELEV P1
02-100A
MAIN
LOBBY
02-100B
SERV.
LOBBY 10
JKL
1 3
1 3
1 3
1 3
1 3
1 3
ELEV P2
ELEV P4
ELEV P5
ELEV P6
ELEV P1
ELEV P3
03-100A
MAIN
LOBBY
03-100B
SERV.
LOBBY
JKL
1 3
1 3
1 3
1 3
1 3
1 3
ELEV P2
ELEV P4
ELEV P5
ELEV P6
ELEV P1
ELEV P3
04-100A
MAIN
LOBBY
04-100B
SERV.
LOBBY 10
CAB AND FIXTURES:
• REMOVE MAIN AND AUXILIARY CAR OPERATING PANELS (COP): CALL
BUTTONS, ALARM BUTTON, STOP SWITCH, DOOR OPEN AND HOLD, DOOR
CLOSE, COMMUNICATIONS, FIRE SERVICE, POSITION INDICATORS AND
DIRECTION INDICATORS.
• REMOVE VOICE ANNUNCIATORS.
• REMOVE DOOR DETECTOR EDGE.
• REMOVE CAR DOORS AND SILL.
• REMOVE CAB ENCLOSURE, VENTILATION, AND CAR DOORS.
• REMOVE CAB INTERIOR: HANDRAIL AND BUMPER RAIL, FLOORING AND
LIGHTING.
• RETAIN EXISTING CERTIFICATE HOLDER.
NOTE: ELEVATOR P5 HAS BOTH FRONT AND REAR ENTRIES
NOTE: RETAIN ELEVATOR P6 EXISTING CAB SILL
MACHINE ROOM:
• REMOVE HOIST MACHINE, MOTOR AND BRAKE ASSEMBLY.
• REMOVE CONTROLLERS AND SELECTORS.
• REMOVE GOVERNORS, HOIST CABLES AND GOVERNOR CABLE.
• REMOVE LIGHTING.
• RETAIN EXISTING VENTILATION.
• RETAIN EXISTING ACCESS DOOR.
• RETAIN EXISTING FIRE EXTINGUISHER.
NOTE: SOME ITEMS MAY BE LOCATED ON THE PENTHOUSE MEZZANINE
WHICH QUALIFIES AS A "CONFINED SPACE"
HOISTWAY:
• REMOVE OVERHEAD SHEAVES.
• REMOVE LIMIT SWITCHES.
• REMOVE CAR ROLLER GUIDE ROLLERS.
• REMOVE CAR DOOR OPERATORS.
• REMOVE DOOR PANELS.
• REMOVE TRACKS, HANGER ROLLERS, PICK-UP ROLLERS, RETAINERS,
INTERLOCKS, GIBS AND CLOSERS.
• REMOVE TRAVEL CABLES.
• REMOVE COMPENSATION CABLES.
• REMOVE CAR AND COUNTERWEIGHT OIL BUFFERS.
• REMOVE GOVERNOR TENSION SHEAVE.
• REMOVE LIGHTS AND LIGHT SWITCH.
• RETAIN EXISTING VENTILATION.
• RETAIN EXISTING SAFETIES; OVERHAUL AND CLEAN AS REQUIRED.
• RETAIN EXISTING CAR TOP AND SLING.
• RETAIN EXISTING PIT LADDER AND REMOUNT AS NECESSARY TO
COMPLY WITH SPECIFICATION 14 21 10.
NOTE: RETAIN ELEVATOR P6 HOISTWAY DOORS
LOBBY:
• REMOVE HALL CALL BUTTONS AND LANTERNS.
• REMOVE HANDRAIL AND BUMPER RAIL (WHERE PRESENT) AND STORE
FOR REINSTALLATION.
• REMOVE CORNER GUARDS (WHERE PRESENT) AND STORE FOR
REINSTALLATION.
• REMOVE WALL MOUNTED EQUIPMENT (WHERE PRESENT) AND STORE
FOR REINSTALLATION.
• REMOVE WALL BASE (WHERE PRESENT) AND PREP SURFACE FOR NEW
WALL BASE.
• PREP PAINTED SURFACES FOR NEW PAINT, CORNER TO CORNER AS
SHOWN.
REMOVE CEILING TILES AND GRIDS AS REQUIRED TO ACCESS PENTHOUSE
FLOOR HATCH ABOVE.
REMOVE STEEL COVER PLATE AND GUARD AT FLOOR OPENING TO ACCESS
NINTH FLOOR LOBBY HATCH.
EXISTING FLOOR HATCH AND GANTRY ABOVE MAY BE USED TO LOWER
EQUIPMENT TO THE NINTH FLOOR FROM THE MACHINE ROOM (THROUGH
THE PENTHOUSE FLOOR HATCH).
SHIP LADDER ACCESS TO PENTHOUSE MEZZANINE.
ACCESS TO MEZZANINE THROUGH STEEL HATCH.
MODIFY ELEVATOR JAMB FOR INSTALLATION OF INCONSPICUOUS RISER, ALL
FLOORS.
REMOVE EXISTING HVAC PER MECHANICAL DRAWINGS.
N or th
E
A
B
F
D
G
HW
C
5 18
00KEYNOTES
KEY PLAN
GENERAL NOTES
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Issued:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
C :\U se rs
\V al ha lla
E ng in ee r\ D oc um en ts
\2 0.
_A
R C
H _R
_g de nt
9T P
JY
.r vt 5/
/2
:0
7:
A M
AD111
BASEMENT - FOURTH FLOOR
DEMOLITION PLANS
MODERNIZATION OF ELEVATORS
P1 - P6
921 NE 13th ST; OKLAHOMA CITY, OK 73104
635-20-017
05/21/2021 GD DCE
100% CONSTRUCTION
DOCUMENTS
VEG 20.16
32'16'8'4'2'0'
N or th
1/8" = 1'-0"
BASEMENT DEMOLITION PLAN
32'16'8'4'2'0'
N or th
1/8" = 1'-0"
GROUND FLOOR DEMOLITION PLAN
32'16'8'4'2'0'
N or th
1/8" = 1'-0"
FIRST FLOOR DEMOLITION PLAN
32'16'8'4'2'0'
N or th
1/8" = 1'-0"
SECOND FLOOR DEMOLITION PLAN
32'16'8'4'2'0'
N or th
1/8" = 1'-0"
THIRD FLOOR DEMOLITION PLAN
32'16'8'4'2'0'
N or th
1/8" = 1'-0"
FOURTH FLOOR DEMOLITION PLAN
JKL
1 3
1 3
1 3
1 3
1 3
1 3
ELEV P2
ELEV P4
ELEV P5
ELEV P6
ELEV P1
ELEV P3
07-100A
MAIN
LOBBY
07-100B
SERV.
LOBBY 10
JKL
1 3
1 3
1 3
1 3
1 3
1 3
ELEV P2
ELEV P4
ELEV P5
ELEV P6
ELEV P1
ELEV P3
08-100A
MAIN
LOBBY
08-100B
SERV.
LOBBY
JKL
1 3
1 3
1 3
1 3
1 3
1 3
ELEV P2
ELEV P4
ELEV P5
ELEV P6
ELEV P1
ELEV P3
09-100A
MAIN
LOBBY
09-100B
SERV.
LOBBY
JKL
1 3
1 3
1 3
1 3
1 3
1 3
ELEV P2
ELEV P4
ELEV P5
ELEV P6
ELEV P1
ELEV P3
05-100A
MAIN
LOBBY
05-100B
SERV.
LOBBY
JKL
1 3
1 3
1 3
1 3
1 3
1 3
ELEV P2
ELEV P4
ELEV P5
ELEV P6
ELEV P1
ELEV P3
06-100A
MAIN
LOBBY
06-100B
SERV.
LOBBY
A. REFER TO SHEET GI003 FOR PHASING AND PROPOSED CONSTRUCTION
BARRIER LOCATIONS.
CAB AND FIXTURES:
• REMOVE MAIN AND AUXILIARY CAR OPERATING PANELS (COP): CALL
BUTTONS, ALARM BUTTON, STOP SWITCH, DOOR OPEN AND HOLD, DOOR
CLOSE, COMMUNICATIONS, FIRE SERVICE, POSITION INDICATORS AND
DIRECTION INDICATORS.
• REMOVE VOICE ANNUNCIATORS.
• REMOVE DOOR DETECTOR EDGE.
• REMOVE CAR DOORS AND SILL.
• REMOVE CAB ENCLOSURE, VENTILATION, AND CAR DOORS.
• REMOVE CAB INTERIOR: HANDRAIL AND BUMPER RAIL, FLOORING AND
LIGHTING.
• RETAIN EXISTING CERTIFICATE HOLDER.
NOTE: ELEVATOR P5 HAS BOTH FRONT AND REAR ENTRIES
NOTE: RETAIN ELEVATOR P6 EXISTING CAB SILL
MACHINE ROOM:
• REMOVE HOIST MACHINE, MOTOR AND BRAKE ASSEMBLY.
• REMOVE CONTROLLERS AND SELECTORS.
• REMOVE GOVERNORS, HOIST CABLES AND GOVERNOR CABLE.
• REMOVE LIGHTING.
• RETAIN EXISTING VENTILATION.
• RETAIN EXISTING ACCESS DOOR.
• RETAIN EXISTING FIRE EXTINGUISHER.
NOTE: SOME ITEMS MAY BE LOCATED ON THE PENTHOUSE MEZZANINE
WHICH QUALIFIES AS A "CONFINED SPACE"
HOISTWAY:
• REMOVE OVERHEAD SHEAVES.
• REMOVE LIMIT SWITCHES.
• REMOVE CAR ROLLER GUIDE ROLLERS.
• REMOVE CAR DOOR OPERATORS.
• REMOVE DOOR PANELS.
• REMOVE TRACKS, HANGER ROLLERS, PICK-UP ROLLERS, RETAINERS,
INTERLOCKS, GIBS AND CLOSERS.
• REMOVE TRAVEL CABLES.
• REMOVE COMPENSATION CABLES.
• REMOVE CAR AND COUNTERWEIGHT OIL BUFFERS.
• REMOVE GOVERNOR TENSION SHEAVE.
• REMOVE LIGHTS AND LIGHT SWITCH.
• RETAIN EXISTING VENTILATION.
• RETAIN EXISTING SAFETIES; OVERHAUL AND CLEAN AS REQUIRED.
• RETAIN EXISTING CAR TOP AND SLING.
• RETAIN EXISTING PIT LADDER AND REMOUNT AS NECESSARY TO
COMPLY WITH SPECIFICATION 14 21 10.
NOTE: RETAIN ELEVATOR P6 HOISTWAY DOORS
LOBBY:
• REMOVE HALL CALL BUTTONS AND LANTERNS.
• REMOVE HANDRAIL AND BUMPER RAIL (WHERE PRESENT) AND STORE
FOR REINSTALLATION.
• REMOVE CORNER GUARDS (WHERE PRESENT) AND STORE FOR
REINSTALLATION.
• REMOVE WALL MOUNTED EQUIPMENT (WHERE PRESENT) AND STORE
FOR REINSTALLATION.
• REMOVE WALL BASE (WHERE PRESENT) AND PREP SURFACE FOR NEW
WALL BASE.
• PREP PAINTED SURFACES FOR NEW PAINT, CORNER TO CORNER AS
SHOWN.
REMOVE CEILING TILES AND GRIDS AS REQUIRED TO ACCESS PENTHOUSE
FLOOR HATCH ABOVE.
REMOVE STEEL COVER PLATE AND GUARD AT FLOOR OPENING TO ACCESS
NINTH FLOOR LOBBY HATCH.
EXISTING FLOOR HATCH AND GANTRY ABOVE MAY BE USED TO LOWER
EQUIPMENT TO THE NINTH FLOOR FROM THE MACHINE ROOM (THROUGH
THE PENTHOUSE FLOOR HATCH).
SHIP LADDER ACCESS TO PENTHOUSE MEZZANINE.
ACCESS TO MEZZANINE THROUGH STEEL HATCH.
MODIFY ELEVATOR JAMB FOR INSTALLATION OF INCONSPICUOUS RISER, ALL
FLOORS.
REMOVE EXISTING HVAC PER MECHANICAL DRAWINGS.
N or th
E
A
B
F
D
G
HW
C
5 18
00KEYNOTES
KEY PLAN
GENERAL NOTES
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Issued:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
C :\U se rs
\V al ha lla
E ng in ee r\ D oc um en ts
\2 0.
_A
R C
H _R
_g de nt
9T P
JY
.r vt 5/
/2
:0
7:
A M
AD112
FIFTH - NINTH FLOOR DEMOLITION
PLANS
MODERNIZATION OF ELEVATORS
P1 - P6
921 NE 13th ST; OKLAHOMA CITY, OK 73104
635-20-017
05/21/2021 GD DCE
100% CONSTRUCTION
DOCUMENTS
VEG 20.16
32'16'8'4'2'0'
N or th
1/8" = 1'-0"
SEVENTH FLOOR DEMOLITION PLAN
32'16'8'4'2'0'
N or th
1/8" = 1'-0"
EIGHTH FLOOR DEMOLITION PLAN
32'16'8'4'2'0'
N or th
1/8" = 1'-0"
NINTH FLOOR DEMOLITION PLAN
32'16'8'4'2'0'
N or th
1/8" = 1'-0"
FIFTH FLOOR DEMOLITION PLAN
32'16'8'4'2'0'
N or th
1/8" = 1'-0"
SIXTH FLOOR DEMOLITION PLAN
JKLM I
ELEV P2
BELOW
ELEV P3
BELOW
ELEV P4
BELOW
ELEV P5
BELOW
ELEV P6
BELOW
ELEV P1
BELOW
PENTHOUSE
BELOW
JKLM I
P2
P3
P4
P5
P6
P1
11 11
A. REFER TO SHEET GI003 FOR PHASING AND PROPOSED CONSTRUCTION
BARRIER LOCATIONS.
JKLM
I
ELEV P3/P4
HOISTWAY
ELEV P5/P6
HOISTWAY
ELEV P1/P2
HOISTWAY
CAB AND FIXTURES:
• REMOVE MAIN AND AUXILIARY CAR OPERATING PANELS (COP): CALL
BUTTONS, ALARM BUTTON, STOP SWITCH, DOOR OPEN AND HOLD, DOOR
CLOSE, COMMUNICATIONS, FIRE SERVICE, POSITION INDICATORS AND
DIRECTION INDICATORS.
• REMOVE VOICE ANNUNCIATORS.
• REMOVE DOOR DETECTOR EDGE.
• REMOVE CAR DOORS AND SILL.
• REMOVE CAB ENCLOSURE, VENTILATION, AND CAR DOORS.
• REMOVE CAB INTERIOR: HANDRAIL AND BUMPER RAIL, FLOORING AND
LIGHTING.
• RETAIN EXISTING CERTIFICATE HOLDER.
NOTE: ELEVATOR P5 HAS BOTH FRONT AND REAR ENTRIES
NOTE: RETAIN ELEVATOR P6 EXISTING CAB SILL
MACHINE ROOM:
• REMOVE HOIST MACHINE, MOTOR AND BRAKE ASSEMBLY.
• REMOVE CONTROLLERS AND SELECTORS.
• REMOVE GOVERNORS, HOIST CABLES AND GOVERNOR CABLE.
• REMOVE LIGHTING.
• RETAIN EXISTING VENTILATION.
• RETAIN EXISTING ACCESS DOOR.
• RETAIN EXISTING FIRE EXTINGUISHER.
NOTE: SOME ITEMS MAY BE LOCATED ON THE PENTHOUSE MEZZANINE
WHICH QUALIFIES AS A "CONFINED SPACE"
HOISTWAY:
• REMOVE OVERHEAD SHEAVES.
• REMOVE LIMIT SWITCHES.
• REMOVE CAR ROLLER GUIDE ROLLERS.
• REMOVE CAR DOOR OPERATORS.
• REMOVE DOOR PANELS.
• REMOVE TRACKS, HANGER ROLLERS, PICK-UP ROLLERS, RETAINERS,
INTERLOCKS, GIBS AND CLOSERS.
• REMOVE TRAVEL CABLES.
• REMOVE COMPENSATION CABLES.
• REMOVE CAR AND COUNTERWEIGHT OIL BUFFERS.
• REMOVE GOVERNOR TENSION SHEAVE.
• REMOVE LIGHTS AND LIGHT SWITCH.
• RETAIN EXISTING VENTILATION.
• RETAIN EXISTING SAFETIES; OVERHAUL AND CLEAN AS REQUIRED.
• RETAIN EXISTING CAR TOP AND SLING.
• RETAIN EXISTING PIT LADDER AND REMOUNT AS NECESSARY TO
COMPLY WITH SPECIFICATION 14 21 10.
NOTE: RETAIN ELEVATOR P6 HOISTWAY DOORS
LOBBY:
• REMOVE HALL CALL BUTTONS AND LANTERNS.
• REMOVE HANDRAIL AND BUMPER RAIL (WHERE PRESENT) AND STORE
FOR REINSTALLATION.
• REMOVE CORNER GUARDS (WHERE PRESENT) AND STORE FOR
REINSTALLATION.
• REMOVE WALL MOUNTED EQUIPMENT (WHERE PRESENT) AND STORE
FOR REINSTALLATION.
• REMOVE WALL BASE (WHERE PRESENT) AND PREP SURFACE FOR NEW
WALL BASE.
• PREP PAINTED SURFACES FOR NEW PAINT, CORNER TO CORNER AS
SHOWN.
REMOVE CEILING TILES AND GRIDS AS REQUIRED TO ACCESS PENTHOUSE
FLOOR HATCH ABOVE.
REMOVE STEEL COVER PLATE AND GUARD AT FLOOR OPENING TO ACCESS
NINTH FLOOR LOBBY HATCH.
EXISTING FLOOR HATCH AND GANTRY ABOVE MAY BE USED TO LOWER
EQUIPMENT TO THE NINTH FLOOR FROM THE MACHINE ROOM (THROUGH
THE PENTHOUSE FLOOR HATCH).
SHIP LADDER ACCESS TO PENTHOUSE MEZZANINE.
ACCESS TO MEZZANINE THROUGH STEEL HATCH.
MODIFY ELEVATOR JAMB FOR INSTALLATION OF INCONSPICUOUS RISER, ALL
FLOORS.
REMOVE EXISTING HVAC PER MECHANICAL DRAWINGS.
N or th
E
A
B
F
D
G
HW
C
5 18
00KEYNOTES
KEY PLAN
GENERAL NOTES
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Issued:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
C :\U se rs
\V al ha lla
E ng in ee r\ D oc um en ts
\2 0.
_A
R C
H _R
_g de nt
9T P
JY
.r vt 5/
/2
:0
7:
A M
AD113
TOP FLOORS DEMOLITION PLANS MODERNIZATION OF ELEVATORS
P1 - P6
921 NE 13th ST; OKLAHOMA CITY, OK 73104
635-20-017
05/21/2021 GD DCE
100% CONSTRUCTION
DOCUMENTS
VEG 20.16
32'16'8'4'2'0'
N or th
1/8" = 1'-0"
PENTHOUSE MEZZANINE DEMOLITION PLAN
32'16'8'4'2'0'
N or th
1/8" = 1'-0"
MACHINE ROOM DEMOLITION PLAN
32'16'8'4'2'0'
N or th
1/8" = 1'-0"
PENTHOUSE DEMOLITION PLAN
JKL
A-320
B-100A
MAIN
LOBBY
B-100B
SERV.
LOBBY
A-320
1 3
ELEV P2
ELEV P3
ELEV P4
ELEV P5
ELEV P6
ELEV P1
1 3
1 3
1 3
1 3
1 3
A-2208
A-220 9
JKL
A-320
G-100A
MAIN
LOBBY
G-100B
SERV.
LOBBY
A-320
1 3
1 3
1 3
1 3
1 3
1 3
ELEV P2
ELEV P3
ELEV P4
ELEV P5
ELEV P6
ELEV P1
A-2205
A-220 7
JKL
A-320
01-100A
MAIN
LOBBY
01-100B
SERV.
LOBBY
A-320
1 3
1 3
1 3
1 3
1 3
1 3
ELEV P2
ELEV P3
ELEV P4
ELEV P5
ELEV P6
ELEV P1
A-2203
A-220 4
JKL
A-320
02-100A
MAIN
LOBBY
02-100B
SERV.
LOBBY
A-320
1 3
1 3
1 3
1 3
1 3
1 3
ELEV P2
ELEV P3
ELEV P4
ELEV P5
ELEV P6
ELEV P1
A-2201
A-220 2
JKL
A-320
03-100A
MAIN
LOBBY
03-100B
SERV.
LOBBY
A-320
1 3
1 3
1 3
1 3
1 3
1 3
ELEV P2
ELEV P4
ELEV P5
ELEV P6
ELEV P1
ELEV P3
A-2217
A-221 8
JKL
A-320
04-100A
MAIN
LOBBY
04-100B
SERV.
LOBBY
A-320
1 3
1 3
1 3
1 3
1 3
1 3
ELEV P2
ELEV P4
ELEV P5
ELEV P6
ELEV P1
ELEV P3
A-2215
A-221 6
A. ICRA BARRIERS SHALL BE INSTALLED PER SPECIFICATION SECTION
"01 35 26 - SAFETY REQUIREMENTS". BARRIER LOCATIONS MAY BE
ADJUSTED FROM RECOMMENDATION ON GI003, BUT MINIMUM DEFINED
CLEARANCES MUST BE MAINTAINED (48" MINIMUM NOT TO EXCEED HALF OF
THE CORRIDOR).
B. EXISTING WALL-MOUNTED ITEMS STORED FOR REINSTALLATION SHALL BE
REINSTALLED IN SAME LOCATION, UNLESS OTHERWISE NOTED.
C. SIGNAGE ATTACHED TO WALL THAT DOES NOT CONFLICT WITH WORK MAY
REMAIN IN PLACE. PROTECT FROM DAMAGE DURING CONSTRUCTION.
CAB AND FIXTURES:
• PROVIDE ASME A17.1-2016 MAIN AND AUXILIARY CAR OPERATING PANELS
(COP) WITH LED CALL REGISTRATION ILLUMINATION, DUAL DIGITAL
POSITION INDICATOR DISPLAY, DOOR OPEN, DOOR HOLD, DOOR CLOSE,
ALARM AND HELP BUTTONS EMERGENCY LIGHTING.
• PROVIDE ELECTRONIC CHIMES.
• PROVIDE EMERGENCY FIREFIGHTERS' SERVICE PHASE II, COMPLIANT
WITH CURRENT EDITION OF ASME A17.1 ELEVATOR SAFETY
REQUIREMENTS.
• PROVIDE 3D DOOR DETECTOR EDGE.
• PROVIDE HANDRAIL AND BUMPER RAIL.
• PROVIDE NEW STAINLESS STEEL CAR DOORS.
• PROVIDE NEW NICKEL SILVER CAR SILL ON P1 THROUGH P5; CLEAN AND
RETAIN ON P6.
• PROVIDE NON-SLIP FLOORING AND LED ILLUMINATION.
• PROVIDE FIRE RECALL FEATURES PER SPECIFICATION 14 21 10.
• PROVIDE NEW MEDICAL EMERGENCY SIGNAGE ON REAR CAB WALL.
• RETAIN EXISTING CERTIFICATE HOLDER.
MACHINE ROOM:
• PROVIDE NEW PERMANENT MAGNET AC GEARLESS HOIST MACHINE AND
VVVF (VARIABLE VOLTAGE/VARIABLE FREQUENCY) DIGITAL MOTOR
REGENERATIVE DRIVE UNIT WITH AUXILIARY SAFETY BRAKE.
• PROVIDE DIGITAL ENCODER SELECTORS.
• PROVIDE GOVERNOR WITH LIVE SHAFT, HOIST CABLES AND GOVERNOR
CABLES.
• PROVIDE LED ILLUMINATION.
• PAINT MACHINE ROOM FLOOR WITH EPOXY PAINT (09 91 00).
• ADD MAINTENANCE CONTROL PROGRAM PER SPECIFICATION 14 21 10.
• PROVIDE BUILDING FIRE PROTECTION INTERFACE MODULES FOR
EMERGENCY FIREFIGHTERS' SERVICE:
1) PRIMARY FIRE RECALL
2) ALTERNATE FIRE RECALL
3) FIRE HAT
• RETAIN EXISTING VENTILATION.
• RETAIN EXISTING ACCESS DOOR.
• RETAIN EXISTING FIRE EXTINGUISHER.
HOISTWAY:
• PROVIDE / RELOCATE OVERHEAD SHEAVES
• PROVIDE NEW ROLLERS ON EXISTING GUIDE RAILS.
• PROVIDE LIMIT SWITCHES.
• PROVIDE NEW GAL-MOVER CAR DOOR OPERATORS
• PROVIDE #4 SATIN FINISH STAINLESS STEEL DOOR PANELS.
• PROVIDE NEW CAR & CWT OIL BUFFERS.
• PROVIDE NEW TOP AND BOTTOM ACCESS PANELS
• PROVIDE GOVERNOR TENSION SHEAVE.
• PAINT PIT FLOOR WITH NON-SKID EPOXY PAINT (09 91 00).
• RETAIN EXISTING VENTILATION.
• RETAIN EXISTING SAFETIES; OVERHAUL AND CLEAN AS REQUIRED.
• RETAIN EXISTING CAR TOP AND SLING.
• RETAIN EXISTING PIT LADDER AND REMOUNT AS NECESSARY TO COMPLY
WITH SPECIFICATION 14 21 10.
LOBBY:
• PROVIDE FLUSH MOUNTED HALL PUSH BUTTON ASSEMBLY.
• CLEAN AND POLISH EXISTING ENTRANCES.
• REINSTALL HANDRAIL AND BUMPER RAIL (WHERE PRESENT).
• REINSTALL CORNER GUARDS (WHERE PRESENT).
• REINSTALL WALL MOUNTED EQUIPMENT.
• PAINT APPROPRIATE SURFACES FROM CORNER TO CORNER, AS SHOWN.
REINSTALL CEILING TILES/GRID, REPLACE BROKEN AND DISCOLORED PIECES
REINSTALL EXISTING COVER PLATE OVER FLOOR OPENING AND REINSTALL
GUARD WHEN NOT IN USE.
SECURE EXISTING FLOOR HATCH WHEN NOT IN USE.
EXISTING SHIP LADDER ACCESS TO PENTHOUSE MEZZANINE.
ACCESS TO PENTHOUSE MEZZANINE THROUGH EXISTING STEEL HATCH.
PROVIDE AND INSTALL NEW STAINLESS STEEL CORNER GUARD 4"x4"x48", 16GA, #4 FINISH.
PROVIDE AND INSTALL NEW VINYL CORNER GUARD; MATCH EXISTING
MATERIAL, COLOR AND FINISH
CLEAN (E) CONC PAD AND REPAINT YELLOW.
PROVIDE AND INSTALL HVAC PER MECHANICAL DRAWINGS.
COVER UNUSED FLOOR OPENINGS AND PROVIDE ROPE GUARDS AT
PENTHOUSE MEZZANINE.
N or th
E
A
B
F
D
G
HW
C
5 18
00KEYNOTES
KEY PLAN
GENERAL NOTES
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Issued:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
C :\U se rs
\V al ha lla
E ng in ee r\ D oc um en ts
\2 0.
_A
R C
H _R
_g de nt
9T P
JY
.r vt 5/
/2
:4
2:
P M
A-111
BASEMENT - FOURTH FLOOR
PLANS
MODERNIZATION OF ELEVATORS
P1 - P6
921 NE 13th ST; OKLAHOMA CITY, OK 73104
635-20-017
05/21/2021 GD DCE
100% CONSTRUCTION
DOCUMENTS
VEG 20.16
32'16'8'4'2'0'
N or th
1/8" = 1'-0"
BASEMENT FLOOR PLAN
32'16'8'4'2'0'
N or th
1/8" = 1'-0"
GROUND FLOOR PLAN
32'16'8'4'2'0'
N or th
1/8" = 1'-0"
FIRST FLOOR PLAN
32'16'8'4'2'0'
N or th
1/8" = 1'-0"
SECOND FLOOR PLAN
32'16'8'4'2'0'
N or th
1/8" = 1'-0"
THIRD FLOOR PLAN
32'16'8'4'2'0'
N or th
1/8" = 1'-0"
FOURTH FLOOR PLAN
JKL
A-320
07-100A
MAIN
LOBBY
07-100B
SERV.
LOBBY
A-320
1 3
1 3
1 3
1 3
1 3
1 3
ELEV P2
ELEV P4
ELEV P5
ELEV P6
ELEV P1
ELEV P3
A-2225
A-222 6
JKL
A-320
08-100A
MAIN
LOBBY
08-100B
SERV.
LOBBY
A-320
1 3
1 3
1 3
1 3
1 3
1 3
ELEV P2
ELEV P4
ELEV P5
ELEV P6
ELEV P1
ELEV P3
A-2223
A-222 4
JKL
A-320
09-100A
MAIN
LOBBY
09-100B
SERV.
LOBBY
A-320
1 3
1 3
1 3
1 3
1 3
1 3
ELEV P2
ELEV P4
ELEV P5
ELEV P6
ELEV P1
ELEV P3
A-2221
A-222 2
JKL
A-320
06-100A
MAIN
LOBBY
06-100B
SERV.
LOBBY
A-320
1 3
1 3
1 3
1 3
1 3
1 3
ELEV P2
ELEV P4
ELEV P5
ELEV P6
ELEV P1
ELEV P3
A-2211
A-221 2
JKL
A-320
A-320
1 3
1 3
1 3
1 3
1 3
1 3
ELEV P2
ELEV P4
ELEV P5
ELEV P6
ELEV P1
ELEV P3
A-2213
A-221 4
05-100B
SERV.
LOBBY
05-100A
MAIN
LOBBY
A. ICRA BARRIERS SHALL BE INSTALLED PER SPECIFICATION SECTION
"01 35 26 - SAFETY REQUIREMENTS". BARRIER LOCATIONS MAY BE
ADJUSTED FROM RECOMMENDATION ON GI003, BUT MINIMUM DEFINED
CLEARANCES MUST BE MAINTAINED (48" MINIMUM NOT TO EXCEED HALF OF
THE CORRIDOR).
B. EXISTING WALL-MOUNTED ITEMS STORED FOR REINSTALLATION SHALL BE
REINSTALLED IN SAME LOCATION, UNLESS OTHERWISE NOTED.
C. SIGNAGE ATTACHED TO WALL THAT DOES NOT CONFLICT WITH WORK MAY
REMAIN IN PLACE. PROTECT FROM DAMAGE DURING CONSTRUCTION.
CAB AND FIXTURES:
• PROVIDE ASME A17.1-2016 MAIN AND AUXILIARY CAR OPERATING PANELS
(COP) WITH LED CALL REGISTRATION ILLUMINATION, DUAL DIGITAL
POSITION INDICATOR DISPLAY, DOOR OPEN, DOOR HOLD, DOOR CLOSE,
ALARM AND HELP BUTTONS EMERGENCY LIGHTING.
• PROVIDE ELECTRONIC CHIMES.
• PROVIDE EMERGENCY FIREFIGHTERS' SERVICE PHASE II, COMPLIANT
WITH CURRENT EDITION OF ASME A17.1 ELEVATOR SAFETY
REQUIREMENTS.
• PROVIDE 3D DOOR DETECTOR EDGE.
• PROVIDE HANDRAIL AND BUMPER RAIL.
• PROVIDE NEW STAINLESS STEEL CAR DOORS.
• PROVIDE NEW NICKEL SILVER CAR SILL ON P1 THROUGH P5; CLEAN AND
RETAIN ON P6.
• PROVIDE NON-SLIP FLOORING AND LED ILLUMINATION.
• PROVIDE FIRE RECALL FEATURES PER SPECIFICATION 14 21 10.
• PROVIDE NEW MEDICAL EMERGENCY SIGNAGE ON REAR CAB WALL.
• RETAIN EXISTING CERTIFICATE HOLDER.
MACHINE ROOM:
• PROVIDE NEW PERMANENT MAGNET AC GEARLESS HOIST MACHINE AND
VVVF (VARIABLE VOLTAGE/VARIABLE FREQUENCY) DIGITAL MOTOR
REGENERATIVE DRIVE UNIT WITH AUXILIARY SAFETY BRAKE.
• PROVIDE DIGITAL ENCODER SELECTORS.
• PROVIDE GOVERNOR WITH LIVE SHAFT, HOIST CABLES AND GOVERNOR
CABLES.
• PROVIDE LED ILLUMINATION.
• PAINT MACHINE ROOM FLOOR WITH EPOXY PAINT (09 91 00).
• ADD MAINTENANCE CONTROL PROGRAM PER SPECIFICATION 14 21 10.
• PROVIDE BUILDING FIRE PROTECTION INTERFACE MODULES FOR
EMERGENCY FIREFIGHTERS' SERVICE:
1) PRIMARY FIRE RECALL
2) ALTERNATE FIRE RECALL
3) FIRE HAT
• RETAIN EXISTING VENTILATION.
• RETAIN EXISTING ACCESS DOOR.
• RETAIN EXISTING FIRE EXTINGUISHER.
HOISTWAY:
• PROVIDE / RELOCATE OVERHEAD SHEAVES
• PROVIDE NEW ROLLERS ON EXISTING GUIDE RAILS.
• PROVIDE LIMIT SWITCHES.
• PROVIDE NEW GAL-MOVER CAR DOOR OPERATORS
• PROVIDE #4 SATIN FINISH STAINLESS STEEL DOOR PANELS.
• PROVIDE NEW CAR & CWT OIL BUFFERS.
• PROVIDE NEW TOP AND BOTTOM ACCESS PANELS
• PROVIDE GOVERNOR TENSION SHEAVE.
• PAINT PIT FLOOR WITH NON-SKID EPOXY PAINT (09 91 00).
• RETAIN EXISTING VENTILATION.
• RETAIN EXISTING SAFETIES; OVERHAUL AND CLEAN AS REQUIRED.
• RETAIN EXISTING CAR TOP AND SLING.
• RETAIN EXISTING PIT LADDER AND REMOUNT AS NECESSARY TO COMPLY
WITH SPECIFICATION 14 21 10.
LOBBY:
• PROVIDE FLUSH MOUNTED HALL PUSH BUTTON ASSEMBLY.
• CLEAN AND POLISH EXISTING ENTRANCES.
• REINSTALL HANDRAIL AND BUMPER RAIL (WHERE PRESENT).
• REINSTALL CORNER GUARDS (WHERE PRESENT).
• REINSTALL WALL MOUNTED EQUIPMENT.
• PAINT APPROPRIATE SURFACES FROM CORNER TO CORNER, AS SHOWN.
REINSTALL CEILING TILES/GRID, REPLACE BROKEN AND DISCOLORED PIECES
REINSTALL EXISTING COVER PLATE OVER FLOOR OPENING AND REINSTALL
GUARD WHEN NOT IN USE.
SECURE EXISTING FLOOR HATCH WHEN NOT IN USE.
EXISTING SHIP LADDER ACCESS TO PENTHOUSE MEZZANINE.
ACCESS TO PENTHOUSE MEZZANINE THROUGH EXISTING STEEL HATCH.
PROVIDE AND INSTALL NEW STAINLESS STEEL CORNER GUARD 4"x4"x48", 16GA, #4 FINISH.
PROVIDE AND INSTALL NEW VINYL CORNER GUARD; MATCH EXISTING
MATERIAL, COLOR AND FINISH
CLEAN (E) CONC PAD AND REPAINT YELLOW.
PROVIDE AND INSTALL HVAC PER MECHANICAL DRAWINGS.
COVER UNUSED FLOOR OPENINGS AND PROVIDE ROPE GUARDS AT
PENTHOUSE MEZZANINE.
N or th
E
A
B
F
D
G
HW
C
5 18
00KEYNOTES
KEY PLAN
GENERAL NOTES
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Issued:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
C :\U se rs
\V al ha lla
E ng in ee r\ D oc um en ts
\2 0.
_A
R C
H _R
_g de nt
9T P
JY
.r vt 5/
/2
:4
2:
P M
A-112
FIFTH - NINTH FLOOR PLANS MODERNIZATION OF ELEVATORS
P1 - P6
921 NE 13th ST; OKLAHOMA CITY, OK 73104
635-20-017
05/21/2021 GD DCE
100% CONSTRUCTION
DOCUMENTS
VEG 20.16
32'16'8'4'2'0'
N or th
1/8" = 1'-0"
SEVENTH FLOOR PLAN
32'16'8'4'2'0'
N or th
1/8" = 1'-0"
EIGHTH FLOOR PLAN
32'16'8'4'2'0'
N or th
1/8" = 1'-0"
NINTH FLOOR PLAN
32'16'8'4'2'0'
N or th
1/8" = 1'-0"
SIXTH FLOOR PLAN
32'16'8'4'2'0'
N or th
1/8" = 1'-0"
FIFTH FLOOR PLAN
JKLM I
PENTHOUSE
BELOW
ELEV P1/P2
HOISTWAY
BELOW
ELEV P3/P4
HOISTWAY
BELOW
ELEV P5/P6
HOISTWAY
BELOW9
JKLM I
A-320
A-320 7
P2
P3
P4
P5
P6
P1
13 13
JKLM I
A-320
A-320
ELEV P3/P4
HOISTWAY
ELEV P5/P6
HOISTWAY
ELEV P1/P2
HOISTWAY
A. ICRA BARRIERS SHALL BE INSTALLED PER SPECIFICATION SECTION
"01 35 26 - SAFETY REQUIREMENTS". BARRIER LOCATIONS MAY BE
ADJUSTED FROM RECOMMENDATION ON GI003, BUT MINIMUM DEFINED
CLEARANCES MUST BE MAINTAINED (48" MINIMUM NOT TO EXCEED HALF OF
THE CORRIDOR).
B. EXISTING WALL-MOUNTED ITEMS STORED FOR REINSTALLATION SHALL BE
REINSTALLED IN SAME LOCATION, UNLESS OTHERWISE NOTED.
C. SIGNAGE ATTACHED TO WALL THAT DOES NOT CONFLICT WITH WORK MAY
REMAIN IN PLACE. PROTECT FROM DAMAGE DURING CONSTRUCTION.
CAB AND FIXTURES:
• PROVIDE ASME A17.1-2016 MAIN AND AUXILIARY CAR OPERATING PANELS
(COP) WITH LED CALL REGISTRATION ILLUMINATION, DUAL DIGITAL
POSITION INDICATOR DISPLAY, DOOR OPEN, DOOR HOLD, DOOR CLOSE,
ALARM AND HELP BUTTONS EMERGENCY LIGHTING.
• PROVIDE ELECTRONIC CHIMES.
• PROVIDE EMERGENCY FIREFIGHTERS' SERVICE PHASE II, COMPLIANT
WITH CURRENT EDITION OF ASME A17.1 ELEVATOR SAFETY
REQUIREMENTS.
• PROVIDE 3D DOOR DETECTOR EDGE.
• PROVIDE HANDRAIL AND BUMPER RAIL.
• PROVIDE NEW STAINLESS STEEL CAR DOORS.
• PROVIDE NEW NICKEL SILVER CAR SILL ON P1 THROUGH P5; CLEAN AND
RETAIN ON P6.
• PROVIDE NON-SLIP FLOORING AND LED ILLUMINATION.
• PROVIDE FIRE RECALL FEATURES PER SPECIFICATION 14 21 10.
• PROVIDE NEW MEDICAL EMERGENCY SIGNAGE ON REAR CAB WALL.
• RETAIN EXISTING CERTIFICATE HOLDER.
MACHINE ROOM:
• PROVIDE NEW PERMANENT MAGNET AC GEARLESS HOIST MACHINE AND
VVVF (VARIABLE VOLTAGE/VARIABLE FREQUENCY) DIGITAL MOTOR
REGENERATIVE DRIVE UNIT WITH AUXILIARY SAFETY BRAKE.
• PROVIDE DIGITAL ENCODER SELECTORS.
• PROVIDE GOVERNOR WITH LIVE SHAFT, HOIST CABLES AND GOVERNOR
CABLES.
• PROVIDE LED ILLUMINATION.
• PAINT MACHINE ROOM FLOOR WITH EPOXY PAINT (09 91 00).
• ADD MAINTENANCE CONTROL PROGRAM PER SPECIFICATION 14 21 10.
• PROVIDE BUILDING FIRE PROTECTION INTERFACE MODULES FOR
EMERGENCY FIREFIGHTERS' SERVICE:
1) PRIMARY FIRE RECALL
2) ALTERNATE FIRE RECALL
3) FIRE HAT
• RETAIN EXISTING VENTILATION.
• RETAIN EXISTING ACCESS DOOR.
• RETAIN EXISTING FIRE EXTINGUISHER.
HOISTWAY:
• PROVIDE / RELOCATE OVERHEAD SHEAVES
• PROVIDE NEW ROLLERS ON EXISTING GUIDE RAILS.
• PROVIDE LIMIT SWITCHES.
• PROVIDE NEW GAL-MOVER CAR DOOR OPERATORS
• PROVIDE #4 SATIN FINISH STAINLESS STEEL DOOR PANELS.
• PROVIDE NEW CAR & CWT OIL BUFFERS.
• PROVIDE NEW TOP AND BOTTOM ACCESS PANELS
• PROVIDE GOVERNOR TENSION SHEAVE.
• PAINT PIT FLOOR WITH NON-SKID EPOXY PAINT (09 91 00).
• RETAIN EXISTING VENTILATION.
• RETAIN EXISTING SAFETIES; OVERHAUL AND CLEAN AS REQUIRED.
• RETAIN EXISTING CAR TOP AND SLING.
• RETAIN EXISTING PIT LADDER AND REMOUNT AS NECESSARY TO COMPLY
WITH SPECIFICATION 14 21 10.
LOBBY:
• PROVIDE FLUSH MOUNTED HALL PUSH BUTTON ASSEMBLY.
• CLEAN AND POLISH EXISTING ENTRANCES.
• REINSTALL HANDRAIL AND BUMPER RAIL (WHERE PRESENT).
• REINSTALL CORNER GUARDS (WHERE PRESENT).
• REINSTALL WALL MOUNTED EQUIPMENT.
• PAINT APPROPRIATE SURFACES FROM CORNER TO CORNER, AS SHOWN.
REINSTALL CEILING TILES/GRID, REPLACE BROKEN AND DISCOLORED PIECES
REINSTALL EXISTING COVER PLATE OVER FLOOR OPENING AND REINSTALL
GUARD WHEN NOT IN USE.
SECURE EXISTING FLOOR HATCH WHEN NOT IN USE.
EXISTING SHIP LADDER ACCESS TO PENTHOUSE MEZZANINE.
ACCESS TO PENTHOUSE MEZZANINE THROUGH EXISTING STEEL HATCH.
PROVIDE AND INSTALL NEW STAINLESS STEEL CORNER GUARD 4"x4"x48", 16GA, #4 FINISH.
PROVIDE AND INSTALL NEW VINYL CORNER GUARD; MATCH EXISTING
MATERIAL, COLOR AND FINISH
CLEAN (E) CONC PAD AND REPAINT YELLOW.
PROVIDE AND INSTALL HVAC PER MECHANICAL DRAWINGS.
COVER UNUSED FLOOR OPENINGS AND PROVIDE ROPE GUARDS AT
PENTHOUSE MEZZANINE.
N or th
E
A
B
F
D
G
HW
C
5 18
00KEYNOTES
KEY PLAN
GENERAL NOTES
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Issued:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
C :\U se rs
\V al ha lla
E ng in ee r\ D oc um en ts
\2 0.
_A
R C
H _R
_g de nt
9T P
JY
.r vt 5/
/2
:0
6:
A M
A-113
TOP FLOORS PLANS MODERNIZATION OF ELEVATORS
P1 - P6
921 NE 13th ST; OKLAHOMA CITY, OK 73104
635-20-017
05/21/2021 GD DCE
100% CONSTRUCTION
DOCUMENTS
VEG 20.16
32'16'8'4'2'0'
N or th
1/8" = 1'-0"
PENTHOUSE MEZZANINE FLOOR PLAN
32'16'8'4'2'0'
N or th
1/8" = 1'-0"
MACHINE ROOM FLOOR PLAN
32'16'8'4'2'0'
N or th
1/8" = 1'-0"
PENTHOUSE FLOOR PLAN
JKL
A-320
A-320
AFF
8' - 0"
AFF
8' - 0"
ELEV P2
ELEV P3
ELEV P4
ELEV P5
ELEV P6
ELEV P1
JKL
A-320
A-320
AFF
8' - 0"
AFF
8' - 9"
ELEV P2
ELEV P3
ELEV P4
ELEV P5
ELEV P6
ELEV P1
JKL
A-320
A-320
AFF
7' - 6"
AFF
8' - 6"
AFF
8' - 0"
ELEV P2
ELEV P3
ELEV P4
ELEV P5
ELEV P6
ELEV P1
JKL
A-320
A-320
AFF
7' - 6"
AFF
8' - 4"
AFF
7' - 6"
AFF
8' - 4"
AFF
7' - 6"
ELEV P2
ELEV P3
ELEV P4
ELEV P5
ELEV P6
ELEV P1
JKL
A-320
A-320
AFF
7' - 8"
AFF
8' - 6"
AFF
8' - 0"
ELEV P2
ELEV P3
ELEV P4
ELEV P5
ELEV P6
ELEV P1
JKL
A-320
A-320
AFF
7' - 6"
AFF
8' - 6"
AFF
8' - 0"
ELEV P2
ELEV P3
ELEV P4
ELEV P5
ELEV P6
ELEV P1
A. RAISED CEILINGS ARE SHOWN HATCHED FOR CLARITY. ICRA BARRIERS ARE
REQUIRED TO EXTEND INTO THE SOFFIT AREA. COORDINATE WITH VHA
INFECTION CONTROL OFFICER.
B. PROVIDE HOIST CAPABLE OF LIFTING THE HEAVIEST ELEVATOR MACHINE;
SECURE TO BOTTOM FLANGE OF EXISTING STEEL GANTRY BEAMS.
C. SURVEY EXISTING LIGHTING AND COORDINATE ICRA BARRIER TO MINIMIZE
IMPACT TO LIGHTING LEVELS IN ELEVATOR LOBBIES.
EXISTING CEILING HATCH TO PENTHOUSE.
PRIOR TO USE OF EXISTING GANTRY BEAMS, EXISTING CONFLICTS MUST BE
CORRECTED. (SHOWN THUS: XXXX)
NEW HVAC DUCTWORK; SEE MECHANICAL DRAWINGS.
N or th
E
A
B
F
D
G
HW
C
5 18
00KEYNOTES
KEY PLAN
GENERAL NOTES
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Issued:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
C :\U se rs
\V al ha lla
E ng in ee r\ D oc um en ts
\2 0.
_A
R C
H _R
_g de nt
9T P
JY
.r vt 5/
/2
:0
7:
A M
A-121
BASEMENT - FOURTH FLOOR
REFLECTED CEILING PLANS
MODERNIZATION OF ELEVATORS
P1 - P6
921 NE 13th ST; OKLAHOMA CITY, OK 73104
635-20-017
05/21/2021 TW GD
100% CONSTRUCTION
DOCUMENTS
VEG 20.16
32'16'8'4'2'0'
1/8" = 1'-0"
GROUND FLOOR RCP
32'16'8'4'2'0'
1/8" = 1'-0"
BASEMENT RCP
32'16'8'4'2'0'
1/8" = 1'-0"
FIRST FLOOR RCP
32'16'8'4'2'0'
1/8" = 1'-0"
SECOND FLOOR RCP
32'16'8'4'2'0'
1/8" = 1'-0"
THIRD FLOOR RCP
32'16'8'4'2'0'
1/8" = 1'-0"
FOURTH FLOOR RCP
JKL
A-320
A-320
AFF
7' - 6"
AFF
8' - 6"
AFF
8' - 0"
ELEV P2
ELEV P3
ELEV P4
ELEV P5
ELEV P6
ELEV P1
JKL
A-320
A-320
AFF
7' - 6"
AFF
8' - 6"
AFF
8' - 0"
ELEV P2
ELEV P3
ELEV P4
ELEV P5
ELEV P6
ELEV P1
JKL
A-320
A-320
AFF
7' - 6"
AFF
8' - 6"
AFF
8' - 0"
ELEV P2
ELEV P3
ELEV P4
ELEV P5
ELEV P6
ELEV P1
JKL
A-320
A-320
AFF
7' - 6"
AFF
8' - 6"
AFF
8' - 0"
AFF
7' - 6"
AFF
7' - 6"
ELEV P2
ELEV P3
ELEV P4
ELEV P5
ELEV P6
ELEV P1
JKL
A-320
A-320
AFF
7' - 6"
AFF
8' - 10"
AFF
8' - 6"
AFF
8' - 0"
AFF
8' - 4"
ELEV P2
ELEV P3
ELEV P4
ELEV P5
ELEV P6
ELEV P1
JKLM
9' - 8 3/4" BO STL
9' - 8 3/4" BO STL
9' - 8 3/4" BO STL
9' - 8 3/4" BO STL
9' - 8 3/4" BO STL
9' - 8 3/4" BO STL
9' - 3 1/4" BO STL
9' - 3 1/4" BO STL
X
X
X
X
X
X
X X X X X X X X X
X
XXXX XXXXXX
10' - 7" BO BEAM
EXISTING CEILING HATCH TO PENTHOUSE.
PRIOR TO USE OF EXISTING GANTRY BEAMS, EXISTING CONFLICTS MUST BE
CORRECTED. (SHOWN THUS: XXXX)
NEW HVAC DUCTWORK; SEE MECHANICAL DRAWINGS.
A. RAISED CEILINGS ARE SHOWN HATCHED FOR CLARITY. ICRA BARRIERS ARE
REQUIRED TO EXTEND INTO THE SOFFIT AREA. COORDINATE WITH VHA
INFECTION CONTROL OFFICER.
B. PROVIDE HOIST CAPABLE OF LIFTING THE HEAVIEST ELEVATOR MACHINE;
SECURE TO BOTTOM FLANGE OF EXISTING STEEL GANTRY BEAMS.
C. SURVEY EXISTING LIGHTING AND COORDINATE ICRA BARRIER TO MINIMIZE
IMPACT TO LIGHTING LEVELS IN ELEVATOR LOBBIES.
N or th
E
A
B
F
D
G
HW
C
5 18
00KEYNOTES
KEY PLAN
GENERAL NOTES
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Issued:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
C :\U se rs
\V al ha lla
E ng in ee r\ D oc um en ts
\2 0.
_A
R C
H _R
_g de nt
9T P
JY
.r vt 5/
/2
:0
7:
A M
A-122
FIFTH - NINTH FLOOR & MACHINE
ROOM REFLECTED CEILING PLANS
MODERNIZATION OF ELEVATORS
P1 - P6
921 NE 13th ST; OKLAHOMA CITY, OK 73104
635-20-017
05/21/2021 TW GD
100% CONSTRUCTION
DOCUMENTS
VEG 20.16
32'16'8'4'2'0'
1/8" = 1'-0"
FIFTH FLOOR RCP
32'16'8'4'2'0'
1/8" = 1'-0"
SIXTH FLOOR RCP
32'16'8'4'2'0'
1/8" = 1'-0"
SEVENTH FLOOR RCP
32'16'8'4'2'0'
1/8" = 1'-0"
EIGHTH FLOOR RCP
32'16'8'4'2'0'
1/8" = 1'-0"
NINTH FLOOR RCP
32'16'8'4'2'0'
1/8" = 1'-0"
MACHINE ROOM RCP
9 10 116
P5 P4 P3 P2 P1
PROVIDE EMERGENCY
KEYWAY, ALL FLOORS, TYP.
ELEVATOR POSITION AND DIRECTION
OF…